IMPORTANT!
Any screws used to fix the rolling shutters tube / awnings must in
no way touch the motor. Please refer to fig. 4.1 to 4.5.
Ä
VL-ME-230-45
Vestaline
E-Line motors
Installation and Operating Instructions
VL-ME-230-45/10Nm
Art.-no.: 01066110
VL-ME-230-45/20Nm
Art.-no.: 01066120
VL-ME-230-45/30Nm
Art.-no.: 01066130
VL-ME-230-45/50Nm
Art.-no.: 01066140
Vestaline motors for controlling roller shutters.
G
H O M E
1100 001 GB 1518 A08
1. Safety precautions
WARNING!
Important safety information.
Follow these instructions to ensure the safety of persons.
The instructions must be stored.
–
– Contact a professional electrician to install the motor, because
the motor requires a power supply of 230VAC, 50 Hz.
–
– Check the motor for signs of mechanical damage after un
packing. If you notice any shipping damage, do not start up
the motor and notify your supplier immediately.
–
– The motor should only be used for the purpose specified by
the manufacturer (refer to the operating instructions). Any
changes or modifications thereof are not permissible and will
result in loss of all warranty claims.
–
– Technical data can be found on the type label of the tubular
motor.
–
– If the motor cannot be operated without presenting a hazard,
it must be switched off and prevented from being switched
on unintentionally.
–
– When performing work on the windows, motor or connected
shades, protect them against unauthorised or unintentional
operation.
–
– Moving parts of the motor installed under 2.5 m above the
floor level should be protected.
–
– This motor is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental abilities or
lack of experience and / or lack of knowledge, unless they are
supervised by a person responsible for their safety, or re-
ceived instructions on how the device is to be used.
–
– Children should be supervised to ensure that they do not
play with the device.
–
– Children are not allowed, to play with fixed controls. Keep
remotes away from children.
–
– The installation has to be checked frequently for imbalance
or of signs of wear, damaged cables or springs, if applicable.
–
– Automatically controlled awnings have to be disconnected
from the supply network, e. g. if maintenance work has to be
done close to them.
Ä
CONTENTS
1. Safety precautions (safety measures)
2. Short description (identification of products)
3. Scope of delivery
4. Intended use
5. Technical data
6. Installation, Assembly, Disassembly
7. Troubleshooting
8. Warranty
9. Maintenance
10. Disposal of waste
11. Declaration of conformity
12. Service / Contact
–
– Before the motor is installed, all unneeded wires must be
removed and all devices which are not required for actuation
with a power drive must be put out of operation.
–
– The actuating element of a hand release is to be installed at
a height of less than 1.8 m.
–
– The mains cable of this device cannot be replaced. If the
mains cable is damaged, the device has to be discarded.
ATTENTION!
Pay attention to the following European guidelines:
–
– The cables must conform to the applicable VDE standard.
–
– If installing motors with a PVC H05VV-F cable, the cable on
surface-mounted outdoor installations and recessed-mounted
installations must be protected by a cable conduit or cable duct.
–
– When installing the motor an all-pole disconnection with a
contact gap of at least 3 mm per pole must be provided.
–
– The up and down directions of the switch resp. button must
be electrically or mechanically locked against each other.
The changeover time for changing the running direction
(up / down) must be least 0.5 sec.
Ä
ATTENTION!
–
– Follow the safety instructions according to EN 60335-2-97.
–
– Additional components for the implementation of the installa-
tion, such as adaptors and brackets must be chosen among
those offered by the producer. These products are listed in
the catalogue supplied on request.
–
– When mounting the drive always use the safest and most
suitable tubular motor and mounting bracket.
–
– For automatically actuated awnings a minimum gap of 0.4 m
to other parts in the area must be maintained when the awn-
ing is fully extended. By using as an awning system the ex-
tended awning must mainain a minimum height of 1.8 m.
Ä
WARNING!
Risk of injury due to improper installation and commissioning.
Improper installation and commissioning may lead to personal inju-
ry or property damage.
Therefore:
–
– When connecting the device, observe the currently valid VDE
standards (in particular DIN VDE 0100/0700), your local pow-
er company’s regulations and the current accident prevention
regulations.
–
– Connect the motor in accordance with the wiring diagram.
–
– It is important for the safety of professional electricians to follow
the user instructions. Please keep instructions for reference.
Ä
Subject to modifications.
© Vestamatic GmbH
2/7
G
H O M E ∙ VL-ME-230-45
Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
2. Short description
Motor 45 mm tube diameter for roller shutters
Programmable upper and lower limit position
Limit positions can be virtual or physical (upper position)
Parallel connection allowed
Anti-block function
Simple setting of the limit position with the “VL-Progset-ME/SMI-230”
(Art.-no.: 54185775)
Re-synchronisation of physical limit positions
Cable 2.5 m white
4. Intended use
These types of tubular motor described in these manual is intended solely
for roller shutters. These types of tubular motor cannot be used in poten-
tially explosive area.
These types of tubular motor are designed for using in a single roller shut-
ter system.
3. Scope of delivery
Motor 45 mm tube diameter with 2.5 m connection cable
Operating instructions
Adapter set, comprising tube adapter / adapter ring
Mounting-kit, comprising safety clip / safety cotter
5. Technical data
Article VL-ME-230-45 / 10Nm
20Nm
30Nm
50Nm
Art.-no.: 01066110 01066120 01066130 01066140
Torque (nominal)
Nm
10
20
30
50
Output speed
rpm
15
15
15
12
Tractive power
kg*
20
40
55
95
Supply voltage
VAC
230
230
230
230
Frequency
Hz
50
50
50
50
Rated power
W
126
165
227
227
Rated current
A
0.55
0.72
0.99
0.99
Running time
Min.
4
4
4
4
Protection degree
IP
44
44
44
44
Length L1
mm
461
481
522
551
* Calculation method: 60 mm octagonal shaft, 1.5 m roller shutter height, regardless
of installation situation, spline, width and friction losses.
6. Installation, assembly, disassembly
Wiring diagram
ATTENTION!
Parallel control of more than one conventional drive motor can
only be implemented by means of isolating relays.
Ä
Wire colours of motor connection cables:
– green/yellow: ground conductor/PE – brown: phase turning direction 1
– blue:
neutral conductor/N – black: phase turning direction 2
Fig. 4.1
Fig. 4.2
Fig. 4.3
Fig. 4.4
Fig. 4.5
Subject to modifications.
© Vestamatic GmbH
3/7
G
H O M E ∙ VL-ME-230-45
Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Electronic limit position setting with Installation tool
How to connect to an Installation tool (VL-Progset-ME/SMI-230 / Art.-no.: 54185775).
IMPORTANT!
–
– Switch off the power supply. Connect the wire of the motor to the terminal
clamps of the installation tool.
–
– It is important that the motor-wire-colors correspond with the installa-
tion-tool-wire-colors, otherwise the motor turning direction could be set
incorrect. Switch on the power supply.
–
– The installation tool is not suitable for continuous operation and has only
been used for set the limit position.
Ä
–
– The connection cable should be installed in an conduit to the junction
box, in compliance with the local building and electrical regulations.
Avoid any contact between moving objects and connection cables by
routing the cables according to figure 1.
–
– Move the roller shutter or screen completely down before disconnecting
the tube connectors.
–
– Dissasembly of tubular shaft.
–
– Place the mounting bracket to the desired position. Assembly of the
motor can be performed on both sides.
–
– Slide the Adapter ring (A) on the adjustment ring (B). Be aware of the
correct installation of the notch with the Adapter (D), (figure 2).
–
– Place the tube adapter (E) on to the motor axle (F) and secure it with the
safety clip (G) that comes within the mounting-kit.
–
– Be careful when sliding the tubular motor completely into the tubular
shaft, until the adapter ring is covered into the tubular shaft, (figure 3).
Under no circumstances external force should be applied to the motor
in any way.
–
– Place the motor head and tubular shaft into the mounting bracket and
check for proper fit. Secure the square pin of the motor head with the
safety cotter that comes with the mounting-kit. Make sure to install the
motor in a position that the adjustment screws are accessible from the
outside.
Assembly
Fig. 1
Fig. 2
Fig. 3
Disassembly
The workflow is the same as in the section “Assembly” (see above) but in
reverse order.
The setup of limit positions can be skipped.
Subject to modifications.
© Vestamatic GmbH
4/7
G
H O M E · VL-ME-230-45
Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Description of installation tool VL-Progset-ME/SMI-230
UP + green LED – Virtual upper limit set
yellow LED – Intermediate position
DOWN + red LED – Virtual lower limit set
green LED – Power
red LED – Change turning direction
Virtual upper limit
Intermediate position
Virtual lower limit
Reset
Change turning direction
Left side: Motor control
Right side: Motor programming
Motor control
Motor programming
Button
Control motor in UP direction
Hold down the button to move the motor in
UP direction.
green
Button
Set “Virtual upper limit position”.
LED
green LED – Virtual upper limit position:
OFF
when no “Virtual upper limit” is set.
Blinking
when programming “Virtual upper limit”
or “RESET” is in progress.
Lit solid
when “Virtual upper limit” programming
sequence has completed.
LED
yellow LED – Intermediate position:
yellow
Button
Set “Intermediate position”.
Hint: Intermediate position:
Not used for these
motor devices.
OFF
when no “Intermediate position” is set.
Blinking
when programming “Intermediate
position” is in progress.
Lit solid
when “Intermediate position” pro gramming
sequence has been completed.
Button
Control motor in DOWN direction
Hold down the button to move the motor in
DOWN direction.
red
Button
Set “Virtual lower limit position”.
LED
red LED – Virtual lower limit position:
OFF
when no “Virtual lower limit” is set.
Blinking
when programming “Virtual lower limit”
or “RESET” is in progress.
Lit solid
when “Virtual lower limit” programming
sequence has completed.
LED
green LED – Power:
OFF
when powerless (it is safe to connect
a motor to the Installation Tool).
green
Button
Reset
Lit solid
when attached to mains 230VAC.
LED
red LED – Change turning direction:
OFF
when no “Change turning direction”
is used.
red
Button
Change motor turning direction.
Blinking
when “Change motor turning direction”
programming sequence is in progress.
Lit solid
when “Change motor turning direction”
programming sequence has completed.