Vestamatic VL-ME-230-45 Series Manuals

1 pdf manual(s) Vestamatic VL-ME-230-45 Series for free download (Document Types: Installation and operating instructions manual)

Document Preview & Text Transcription

Subject to modifications. © Vestamatic GmbH 1/7 G H O M E  ∙ VL-ME-230-45 Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com IMPORTANT! Any screws used to fix the rolling shutters tube / awnings must in no way touch the motor. Please refer to fig. 4.1 to 4.5. Ä VL-ME-230-45 Vestaline E-Line motors Installation and Operating Instructions VL-ME-230-45/10Nm Art.-no.: 01066110 VL-ME-230-45/20Nm Art.-no.: 01066120 VL-ME-230-45/30Nm Art.-no.: 01066130 VL-ME-230-45/50Nm Art.-no.: 01066140 Vestaline motors for controlling roller shutters. G H O M E 1100 001 GB 1518 A08 1. Safety precautions WARNING! Important safety information. Follow these instructions to ensure the safety of persons. The instructions must be stored. – – Contact a professional electrician to install the motor, be­cause the motor requires a power supply of 230VAC, 50 Hz. – – Check the motor for signs of mechanical damage after un­ packing. If you notice any shipping damage, do not start up the motor and notify your supplier immediately. – – The motor should only be used for the purpose specified by the manufacturer (refer to the operating instructions). Any ­changes or modifications thereof are not permissible and will result in loss of all warranty claims. – – Technical data can be found on the type label of the tubular motor. – – If the motor cannot be operated without presenting a hazard, it must be switched off and prevented from being switched on unintentionally. – – When performing work on the windows, motor or connected shades, protect them against unauthorised or unintentional operation. – – Moving parts of the motor installed under 2.5 m above the floor level should be protected. – – This motor is not intended for use by persons (including chil- dren) with reduced physical, sensory or mental abilities or lack of experience and / or lack of knowledge, unless they are supervised by a person responsible for their safety, or re- ceived instructions on how the device is to be used. – – Children should be supervised to ensure that they do not play with the device. – – Children are not allowed, to play with fixed controls. Keep remotes away from children. – – The installation has to be checked frequently for imbalance or of signs of wear, damaged cables or springs, if applicable. – – Automatically controlled awnings have to be disconnected from the supply network, e. g. if maintenance work has to be done close to them. Ä CONTENTS 1. Safety precautions (safety measures) 2. Short description (identification of products) 3. Scope of delivery 4. Intended use 5. Technical data 6. Installation, Assembly, Disassembly 7. Troubleshooting 8. Warranty 9. Maintenance 10. Disposal of waste 11. Declaration of conformity 12. Service / Contact – – Before the motor is installed, all un­needed wires must be removed and all devices which are not required for actua­tion with a power drive must be put out of operation. – – The actuating element of a hand release is to be installed at a height of less than 1.8 m. – – The mains cable of this device cannot be replaced. If the mains cable is damaged, the device has to be discarded. ATTENTION! Pay attention to the following European guidelines: – – The cables must conform to the applicable VDE standard. – – If installing motors with a PVC H05VV-F cable, the cable on surface-mounted outdoor installations and recessed-mounted installations must be protected by a cable conduit or cable duct. – – When installing the motor an all-pole disconnection with a contact gap of at least 3 mm per pole must be provided. – – The up and down directions of the switch resp. button must be electrically or mechanically locked against each ­other. The changeover time for changing the running direction (up / down) must be least 0.5 sec. Ä ATTENTION! – – Follow the safety instructions according to EN 60335-2-97. – – Additional components for the implementation of the installa- tion, such as adaptors and brackets must be chosen among those offered by the producer. These products are listed in the catalogue supplied on request. – – When mounting the drive always use the safest and most suitable tubular motor and mounting bracket. – – For automatically actuated awnings a minimum gap of 0.4 m to other parts in the area must be maintained when the awn- ing is fully extended. By using as an awning system the ex- tended awning must mainain a minimum height of 1.8 m. Ä WARNING! Risk of injury due to improper installation and commissioning. Improper installation and commissioning may lead to personal inju- ry or property damage. Therefore: – – When connecting the device, observe the currently valid VDE standards (in particular DIN VDE 0100/0700), your local pow- er company’s regulations and the current accident prevention regulations. – – Connect the motor in accordance with the wiring diagram. – – It is important for the safety of professional electricians to follow the user instructions. Please keep instructions for reference. Ä Subject to modifications. © Vestamatic GmbH 2/7 G H O M E  ∙ VL-ME-230-45 Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com 2. Short description „ „ Motor 45 mm tube diameter for roller shutters „ „ Programmable upper and lower limit position „ „ Limit positions can be virtual or physical (upper position) „ „ Parallel connection allowed „ „ Anti-block function „ „ Simple setting of the limit position with the “VL-Progset-ME/SMI-230” (Art.-no.: 54185775) „ „ Re-synchronisation of physical limit positions „ „ Cable 2.5 m white 4. Intended use These types of tubular motor described in these manual is intended ­solely for roller shutters. These types of ­tubular motor cannot be used in poten- tially explosive area. These types of tubular motor are designed for using in a single roller shut- ter system. 3. Scope of delivery „ „ Motor 45 mm tube diameter with 2.5 m connection cable „ „ Operating instructions „ „ Adapter set, comprising tube adapter / adapter ring „ „ Mounting-kit, comprising safety clip / safety cotter 5. Technical data Article VL-ME-230-45 / 10Nm 20Nm 30Nm 50Nm Art.-no.: 01066110 01066120 01066130 01066140 Torque (nominal) Nm 10 20 30 50 Output speed rpm 15 15 15 12 Tractive power kg* 20 40 55 95 Supply voltage VAC 230 230 230 230 Frequency Hz 50 50 50 50 Rated power W 126 165 227 227 Rated current A 0.55 0.72 0.99 0.99 Running time Min. 4 4 4 4 Protection degree IP 44 44 44 44 Length L1 mm 461 481 522 551 * Calculation method: 60 mm octagonal shaft, 1.5 m roller shutter height, regardless of installation situation, spline, width and friction losses. 6. Installation, assembly, disassembly Wiring diagram ATTENTION! Parallel control of more than one conventional drive motor can only be implemented by means of isolating relays. Ä Wire colours of motor connection cables: – green/yellow: ground conductor/PE – brown: phase turning direction 1 – blue: neutral conductor/N – black: phase turning direction 2 Fig. 4.1 Fig. 4.2 Fig. 4.3 Fig. 4.4 Fig. 4.5 Subject to modifications. © Vestamatic GmbH 3/7 G H O M E  ∙ VL-ME-230-45 Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com Electronic limit position setting with Installation tool How to connect to an Installation tool (VL-Progset-ME/SMI-230 / Art.-no.: 54185775). IMPORTANT! – – Switch off the power supply. Connect the wire of the motor to the terminal clamps of the installation tool. – – It is important that the motor-wire-colors correspond with the installa- tion-tool-wire-colors, otherwise the motor turning direction could be set incorrect. Switch on the power supply. – – The installation tool is not suitable for continuous operation and has only been used for set the limit position. Ä – – The connection cable should be installed in an conduit to the junction box, in compliance with the local building and electrical regulations. Avoid any contact between moving objects and connection cables by routing the ­cables according to figure 1. – – Move the roller shutter or screen completely down before disconnecting the tube connectors. – – Dissasembly of tubular shaft. – – Place the mounting bracket to the desired position. Assembly of the motor can be performed on both sides. – – Slide the Adapter ring (A) on the adjustment ring (B). Be aware of the correct installation of the notch with the Adapter (D), (figure 2). – – Place the tube adapter (E) on to the motor axle (F) and secure it with the safety clip (G) that comes within the mounting-kit. – – Be careful when sliding the tubular motor completely into the tubular shaft, until the adapter ring is covered into the tubular shaft, (figure 3). Under no circumstances external force should be applied to the motor in any way. – – Place the motor head and tubular shaft into the mounting bracket and check for proper fit. Secure the square pin of the motor head with the safety cotter that comes with the mounting-kit. Make sure to install the motor in a position that the adjustment screws are accessible from the outside. Assembly Fig. 1 Fig. 2 Fig. 3 Disassembly The workflow is the same as in the section “Assembly” (see above) but in reverse order. The setup of limit positions can be skipped. Subject to modifications. © Vestamatic GmbH 4/7 G H O M E · VL-ME-230-45 Art.-Nr.: 1100 001 GB 1518 A08 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com Description of installation tool VL-Progset-ME/SMI-230 UP + green LED – Virtual upper limit set yellow LED – Intermediate position DOWN + red LED – Virtual lower limit set green LED – Power red LED – Change turning direction Virtual upper limit Intermediate position Virtual lower limit Reset Change turning direction Left side: Motor control Right side: Motor programming Motor control Motor programming Button Control motor in UP direction Hold down the button to move the motor in UP direction. green Button Set “Virtual upper limit position”. LED green LED – Virtual upper limit position: OFF when no “Virtual upper limit” is set. Blinking when programming “Virtual upper limit” or “RESET” is in progress. Lit solid when “Virtual upper limit” programming sequence has completed. LED yellow LED – Intermediate position: yellow Button Set “Intermediate position”. Hint: Intermediate position: Not used for these motor devices. OFF when no “Intermediate position” is set. Blinking when programming “Intermediate position” is in progress. Lit solid when “Intermediate position” pro gramming sequence has been completed. Button Control motor in DOWN direction Hold down the button to move the motor in DOWN direction. red Button Set “Virtual lower limit position”. LED red LED – Virtual lower limit position: OFF when no “Virtual lower limit” is set. Blinking when programming “Virtual lower limit” or “RESET” is in progress. Lit solid when “Virtual lower limit” programming sequence has completed. LED green LED – Power: OFF when powerless (it is safe to connect a motor to the Installation Tool). green Button Reset Lit solid when attached to mains 230VAC. LED red LED – Change turning direction: OFF when no “Change turning direction” is used. red Button Change motor turning direction. Blinking when “Change motor turning direction” programming sequence is in progress. Lit solid when “Change motor turning direction” programming sequence has completed.