Victron energy SmartShunt Manuals

2 pdf manual(s) Victron energy SmartShunt for free download (Document Types: Manual , Quick installation manual)

Victron energy SmartShunt Manual  Main Page Preview

Manual  [PDF] (39 pages)

  • Updated: 29.03.2026

Document Preview & Text Transcription

Manual - SmartShunt Rev 06 06/2021 ENGLISH VE.Direct - Aux Error - Vbatt + - SmartShunt Table of Contents 1. Safety precautions ................................................................................................................... 1 1.1. Battery safety warnings ..................................................................................................... 1 1.2. Transport and storage ...................................................................................................... 1 2. Introduction ........................................................................................................................... 2 2.1. Battery monitor .............................................................................................................. 2 2.2. Why should I monitor my battery? ......................................................................................... 2 2.3. Sizing ......................................................................................................................... 2 2.4. The VictronConnect app .................................................................................................... 2 2.5. Accessories .................................................................................................................. 3 3. Installation ............................................................................................................................. 4 3.1. What's in the box? ........................................................................................................... 4 3.2. Mounting ...................................................................................................................... 4 3.3. Basic electrical connections ................................................................................................ 4 3.3.1. Battery minus connection ........................................................................................ 5 3.3.2. System minus connection ........................................................................................ 5 3.3.3. Vbatt connection .................................................................................................. 5 3.4. Auxiliary electrical connections ............................................................................................ 5 3.4.1. Auxiliary connection for monitoring the voltage of a second battery ........................................ 5 3.4.2. Auxiliary connection midpoint battery bank monitoring ....................................................... 6 3.4.3. Auxiliary connection for temperature monitoring .............................................................. 7 3.5. GX device connection ....................................................................................................... 7 4. Configuration ......................................................................................................................... 8 4.1. The VictronConnect app .................................................................................................... 8 4.2. Place the fuse ................................................................................................................ 8 4.3. Connect to the Battery monitor ............................................................................................ 9 4.4. Update firmware ............................................................................................................. 9 4.5. Make essential settings ..................................................................................................... 9 4.5.1. Set the battery capacity value ................................................................................... 9 4.5.2. Set the charged voltage value ................................................................................... 9 4.5.3. Set state of charge .............................................................................................. 10 4.5.4. Set the auxiliary input function ................................................................................. 10 4.6. Make Lithium settings (if needed) ....................................................................................... 10 5. Operation ............................................................................................................................ 12 5.1. How does the SmartShunt work? ........................................................................................ 12 5.2. Readout overview ......................................................................................................... 12 5.3. Synchronising the SmartShunt ........................................................................................... 13 5.3.1. Automatic synchronisation ..................................................................................... 13 5.3.2. Manual synchronisation ........................................................................................ 13 5.4. Alarms ...................................................................................................................... 14 5.5. History data ................................................................................................................ 14 5.6. Trends ...................................................................................................................... 15 5.7. LED Status codes Bluetooth module .................................................................................... 15 6. Interfacing ........................................................................................................................... 16 6.1. VictronConnect via USB .................................................................................................. 16 6.2. Connecting to a GX device and VRM ................................................................................... 16 6.3. Connecting to VE.Smart network ........................................................................................ 16 6.4. Custom integration (programming required) ........................................................................... 17 7. All features and settings .......................................................................................................... 18 7.1. Battery settings ............................................................................................................ 18 7.1.1. Battery capacity ................................................................................................. 18 7.1.2. Charged voltage ................................................................................................. 18 7.1.3. Discharge floor .................................................................................................. 18 7.1.4. Tail current ....................................................................................................... 19 7.1.5. Charged detection time ......................................................................................... 19 7.1.6. Peukert exponent ............................................................................................... 19 Manual - SmartShunt 7.1.7. Charge efficiency factor ........................................................................................ 19 7.1.8. Current threshold ................................................................................................ 19 7.1.9. Time-to-go averaging period ................................................................................... 19 7.1.10. Battery starts synchronised ................................................................................... 20 7.1.11. State of charge ................................................................................................. 20 7.1.12. Synchronise SoC to 100% .................................................................................... 20 7.1.13. Zero current calibration ....................................................................................... 20 7.2. Alarm settings .............................................................................................................. 21 7.2.1. SoC alarm setting ............................................................................................... 21 7.2.2. Low voltage alarm ............................................................................................... 21 7.2.3. High voltage alarm .............................................................................................. 21 7.2.4. Low starter voltage alarm ...................................................................................... 22 7.2.5. High starter voltage alarm ...................................................................................... 23 7.2.6. Midpoint deviation alarm ....................................................................................... 23 7.2.7. High temperature alarm ........................................................................................ 23 7.2.8. Low temperature alarm ......................................................................................... 23 7.3. Miscellaneous settings .................................................................................................... 24 7.3.1. Aux input ......................................................................................................... 24 7.3.2. Temperature coefficient ......................................................................................... 24 7.4. Temperature unit setting .................................................................................................. 24 7.5. Product settings ........................................................................................................... 24 7.5.1. Reset to defaults ................................................................................................ 24 7.5.2. Custom name .................................................................................................... 24 7.5.3. Firmware ......................................................................................................... 24 7.5.4. Changing PIN code ............................................................................................. 24 7.5.5. Disabling and re-enabling Bluetooth .......................................................................... 25 7.5.6. Serial number .................................................................................................... 25 7.6. Saving, loading and sharing settings .................................................................................... 25 7.7. Reset history ............................................................................................................... 25 7.8. Reset PIN code ............................................................................................................ 25 8. Battery capacity and Peukert exponent ........................................................................................ 26 9. Midpoint voltage monitoring ..................................................................................................... 28 9.1. Battery bank and midpoint wiring diagrams ............................................................................ 28 9.1.1. Connecting and monitoring midpoint in a 24V battery bank ................................................ 28 9.1.2. Connecting and monitoring midpoint in a 48V battery bank ................................................ 29 9.2. Midpoint deviation calculation ............................................................................................ 29 9.3. Setting the alarm level .................................................................................................... 29 9.4. Alarm delay ................................................................................................................ 30 9.5. What to do in case of an alarm during charging ....................................................................... 30 9.6. What to do in case of an alarm during discharging .................................................................... 30 9.7. The Battery Balancer ...................................................................................................... 31 10. Troubleshooting .................................................................................................................. 32 10.1. Functionality issues ...................................................................................................... 32 10.1.1. Unit is dead, no lights on ...................................................................................... 32 10.1.2. Auxiliary port not working ..................................................................................... 32 10.1.3. Can’t change settings ......................................................................................... 32 10.2. Connection issues ....................................................................................................... 32 10.2.1. Cannot connect via Bluetooth ................................................................................ 32 10.2.2. PIN code lost ................................................................................................... 33 10.3. Incorrect readings ........................................................................................................ 33 10.3.1. Charge and discharge current are inverted ................................................................. 33 10.3.2. Incomplete current reading ................................................................................... 33 10.3.3. There is a current reading while no current flows .......................................................... 33 10.3.4. Incorrect state of charge reading ............................................................................ 34 10.3.5. State of charge is missing .................................................................................... 34 10.3.6. State of charge does not reach 100% ....................................................................... 34 10.3.7. State of charge always shows 100% ........................................................................ 34 10.3.8. State of charge does not increase fast enough or too fast when charging .............................. 35 10.3.9. Incorrect battery voltage reading ............................................................................. 35 10.3.10. Incorrect start battery voltage reading ..................................................................... 35 10.3.11. Synchronisation issues ...................................................................................... 35 11. Technical data ..................................................................................................................... 36 Manual - SmartShunt

Document Preview & Text Transcription

Page 1 Rev: 00 1 2 3 4 5  Working in the vicinity of a lead acid battery is dangerous. Batteries can generate explosive gases during operation. Never smoke or allow a spark or flame in the vicinity of a battery. Provide sufficient ventilation around the battery.  Wear eye and clothing protection. Avoid touching eyes while working near batteries. Wash your hands when done.  If battery acid contacts skin or clothing, wash them immediately with soap and water. If acid enters an eye, immediately flood the eye with running cold water for at least 15 minutes and get medical attention immediately.  Be careful when using metal tools in the vicinity of batteries. Dropping a metal tool onto a battery might cause a short circuit and possibly an explosion.  Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery. A battery can produce a short circuit current high enough to melt objects such as rings, causing severe burns.  Connect the negative battery terminal to the SmartShunt BATTERY MINUS terminal  Connect the negative DC electrical system terminal to the SmartShunt LOAD MINUS terminal  Connect the power cable between the positive battery terminal and the SmartShunt Vbatt+ terminal  SmartShunt  Two power cables  The full manual is available online Battery safety warnings SmartShunt Quick installation guide DC Loads Introduction Connect battery negative Connect power cable Connect DC load negative DC Loads DC Loads www.victronenergy.com. au/battery-monitors/ smart-battery-shunt SmartShunt manual: SmartShunt Quick installation guide Page 2 Rev: 00 6 7 8 9 10 11  Connect the power cable between the positive terminal of the second battery and the SmartShunt Aux terminal  Connect the negative of both batteries together Monitoring voltage of a second battery Monitoring midpoint of a battery bank Monitoring battery temperature Make essential VictronConnect settings Connecting to a GX device Download and connect VictronConnect  Connect the power cable between the battery bank midpoint and the SmartShunt Aux terminal  Connect the (not included) temperature sensor ASS000100000 to the positive battery terminal  Connect the red wire to the Vbatt+ terminal  Connect the black wire to the Aux terminal  Download VictronConnect  Connect to the SmartShunt DC Loads Optional Optional Optional Optional  Connect the (not included) VE.Direct cable ASS03053xxxx between the VE.Direct ports of the SmartShunt and the GX device  Set the battery capacity  Set the functionality of the auxiliary input (if used)  Set the charged voltage parameter: Additional settings for lithium batteries:  Set the charge efficiency at 99%  Set the Peukert exponent at 1.05 DC Loads DC Loads DC Loads www.victronenergy.com/ live/victronconnect:start VictronConnect manual: DC Loads https://ve3.nl/Venus-OS:start Victron GX product range: