Vonyx AP800A Manuals

2 pdf manual(s) Vonyx AP800A for free download (Document Types: Instruction manual)

Available Documents for AP800A:

Vonyx AP800A Instruction manual Main Page Preview

Instruction manual [PDF] (16 pages)

  • Brand: Vonyx
  • Model: AP800A
  • Format: PDF
  • Key Aspects: End-of-Life Handling and Disposal, Common Issue Diagnostic Flows, Environmental Factors and Restrictions
  • Updated: 19.05.2026
  • Source File: 971799.pdf
  • Pages: 16
  • Description: User instructions for the Vonyx AP800A.

Document Preview & Text Transcription

AP800A Hi-End Active 8" AP1000A Hi-End Active 10" Ref. nr.: 170.340 / 170.341 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES MANUEL D'INSTRUCTIONS V1.1 2 3 ENGLISH Congratulations to the purchase of this Vonyx product. Please read this manual thoroughly prior to using the unit in order to benefit fully from all features. Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical shock. Keep the manual for future reference. - Prior to using the unit, please ask advice from a specialist. When the unit is switched on for the first time, some smell may occur. This is normal and will disappear after a while. - The unit contains voltage carrying parts. Therefore do NOT open the housing. - Do not place metal objects or pour liquids into the unit This may cause electrical shock and malfunction. - Do not place the unit near heat sources such as radiators, etc. Do not place the unit on a vibrating surface. Do not cover the ventilation holes. - The unit is not suitable for continuous use. - Be careful with the mains lead and do not damage it. A faulty or damaged mains lead can cause electrical shock and malfunction. - When unplugging the unit from a mains outlet, always pull the plug, never the lead. - Do not plug or unplug the unit with wet hands. - If the plug and/or the mains lead are damaged, they need to be replaced by a qualified technician. - If the unit is damaged to such an extent that internal parts are visible, do NOT plug the unit into a mains outlet and DO NOT switch the unit on. Contact your dealer. Do NOT connect the unit to a rheostat or dimmer. - To avoid fire and shock hazard, do not expose the unit to rain and moisture. - All repairs should be carried out by a qualified technician only. - Connect the unit to an earthed mains outlet (220- 240Vac/50Hz) protected by a 10-16A fuse. - During a thunderstorm or if the unit will not be used for a longer period of time, unplug it from the mains. The rule is: Unplug it from the mains when not in use. - If the unit has not been used for a longer period of time, condensation may occur. Let the unit reach room temperature before you switch it on. Never use the unit in humid rooms or outdoors. - To prevent accidents in companies, you must follow the applicable guide lines and follow the instructions. - Do not repeatedly switch the fixture on and off. This shortens the life time. - Keep the unit out of the reach of children. Do not leave the unit unattended. - Do not use cleaning sprays to clean switches. The residues of these sprays cause deposits of dust and grease. In case of malfunction, always seek advice from a specialist. - Do not force the controls. - If this unit is with speaker inside which can cause magnetic field. Keep this unit at least 60cm away from computer or TV. - If this unit is with built-in lead-acid rechargeable battery. Please recharge the battery every 3 months if you are not going to use the unit for a long period of time. Or the battery may be damaged. - If the battery is damaged please replace with same specifications battery. And dispose the damaged battery environment friendly. - If the unit has fallen, always have it checked by a qualified technician before you switch the unit on again. - Do not use chemicals to clean the unit. They damage the varnish. Only clean the unit with a dry cloth. - Keep away from electronic equipment that may cause interference. - Only use original spares for repairs, otherwise serious damage and/or dangerous radiation may occur. - Switch the unit off prior to unplugging it from the mains and/or other equipment. Unplug all leads and cables prior to moving the unit. - Make sure that the mains lead cannot be damaged when people walk on it. Check the mains lead before every use for damages and faults! - The mains voltage is 220-240Vac/50Hz. Check if power outlet match. If you travel, make sure that the mains voltage of the country is suitable for this unit. - Keep the original packing material so that you can transport the unit in safe conditions. This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sufficient magnitude to cause a shock hazard. This mark attracts the attention of the user to important instructions that are contained in the manual and that he should read and adhere to. The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate and their guarantee! NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/41°F and 35°C/95°F. Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed. The specifications are typical. The actual values can slightly change from one unit to the other. Specifications can be changed without prior notice. Do not attempt to make any repairs yourself. This would invalid your warranty. Do not make any changes to the unit. This would also invalid your warranty. The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the warnings contained in this manual. Vonyx cannot be held responsible for personal injuries caused by a disrespect of the safety recommendations and warnings. This is also applicable to all damages in whatever form. 4 REAR PANEL 1. Jack ¼” input connector for microphone. 2. RCA line input connector for the audio input source e.g. mixer, CD player, etc. 3. Volume control for the microphone. 4. Volume control for the line input. 5. Tone control. 6. Power ON/OFF LED indicator. This clear green indicator will light when the amplifier is turned on. Passive speaker output connector, minimum load 8 Ohm! TROUBLESHOOTING One certain method of determining if a speaker is faulty is to substitute a speaker that is known to work correctly for the suspected problem speaker. If the “normally correct speaker” is experiencing the same difficulties or problems as the suspected problem speaker, use the information below to isolate the problem. Problem Possible cause Action No output Cables Reseat all connectors Substitute known good cables Check solder joins Inspect cable for damage Inspect wire or connector for stray strand that may short Intermittent Poor connections While it is possible for a faulty speaker to exhibit intermittent output, it’s more likely that an output cable/connector is the problem. Check the soldering on your connectors. Constant noise, buzzing and/or humming Faulty electronic Any constant noise originates in the amplifier, mixer, signal processing, source device in the signal devices, or line-level wiring. Check and correct system grounding as required. Chain check for noisy sources or electronic components. Check wiring for shielding. Poor low- frequency output Improper polarity When two speakers in close proximity to each other are connected out-of-polarity, they can partially cancel each other out, especially at low frequencies. Check your speaker cables to be sure they are all identically wired and connected. Check the balanced line signal cables to be sure they are all correctly wired.
Vonyx AP800A Instruction manual Main Page Preview

Instruction manual [PDF] (24 pages)

  • Brand: Vonyx
  • Model: AP800A
  • Format: PDF
  • Key Aspects: Documentation and Revision History, Regulatory Compliance and Standards, Detailed Installation Instructions
  • Updated: 12.09.2026
  • Source File: 2430918.pdf
  • Pages: 24
  • Description: Official product manual for the Vonyx AP800A.

Document Preview & Text Transcription

AP Hi-End Active Series Ref. nr.: 170.340; 170.341; 170.342; 170.343 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES MANUEL D'INSTRUCTIONS INSTRUKCJA OBSŁUGI V2.0 2 3 ENGLISH Congratulations to the purchase of this Vonyx product. Please read this manual thoroughly prior to using the unit in order to benefit fully from all features. Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical shock. Keep the manual for future reference. - Prior to using the unit, please ask advice from a specialist. When the unit is switched on for the first time, some smell may occur. This is normal and will disappear after a while. - The unit contains voltage carrying parts. Therefore do NOT open the housing. - Do not place metal objects or pour liquids into the unit This may cause electrical shock and malfunction. - Do not place the unit near heat sources such as radiators, etc. Do not place the unit on a vibrating surface. Do not cover the ventilation holes. - The unit is not suitable for continuous use. - Be careful with the mains lead and do not damage it. A faulty or damaged mains lead can cause electrical shock and malfunction. - When unplugging the unit from a mains outlet, always pull the plug, never the lead. - Do not plug or unplug the unit with wet hands. - If the plug and/or the mains lead are damaged, they need to be replaced by a qualified technician. - If the unit is damaged to such an extent that internal parts are visible, do NOT plug the unit into a mains outlet and DO NOT switch the unit on. Contact your dealer. Do NOT connect the unit to a rheostat or dimmer. - To avoid fire and shock hazard, do not expose the unit to rain and moisture. - All repairs should be carried out by a qualified technician only. - Connect the unit to an earthed mains outlet (220- 240Vac/50Hz) protected by a 10-16A fuse. - During a thunderstorm or if the unit will not be used for a longer period of time, unplug it from the mains. The rule is: Unplug it from the mains when not in use. - If the unit has not been used for a longer period of time, condensation may occur. Let the unit reach room temperature before you switch it on. Never use the unit in humid rooms or outdoors. - To prevent accidents in companies, you must follow the applicable guide lines and follow the instructions. - Do not repeatedly switch the fixture on and off. This shortens the life time. - Keep the unit out of the reach of children. Do not leave the unit unattended. - Do not use cleaning sprays to clean switches. The residues of these sprays cause deposits of dust and grease. In case of malfunction, always seek advice from a specialist. - Do not force the controls. - If this unit is with speaker inside which can cause magnetic field. Keep this unit at least 60cm away from computer or TV. - If this unit is with built-in lead-acid rechargeable battery. Please recharge the battery every 3 months if you are not going to use the unit for a long period of time. Or the battery may be damaged. - If the battery is damaged please replace with same specifications battery. And dispose the damaged battery environment friendly. - If the unit has fallen, always have it checked by a qualified technician before you switch the unit on again. - Do not use chemicals to clean the unit. They damage the varnish. Only clean the unit with a dry cloth. - Keep away from electronic equipment that may cause interference. - Only use original spares for repairs, otherwise serious damage and/or dangerous radiation may occur. - Switch the unit off prior to unplugging it from the mains and/or other equipment. Unplug all leads and cables prior to moving the unit. - Make sure that the mains lead cannot be damaged when people walk on it. Check the mains lead before every use for damages and faults! - The mains voltage is 220-240Vac/50Hz. Check if power outlet match. If you travel, make sure that the mains voltage of the country is suitable for this unit. - Keep the original packing material so that you can transport the unit in safe conditions. This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sufficient magnitude to cause a shock hazard. This mark attracts the attention of the user to important instructions that are contained in the manual and that he should read and adhere to. The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate and their guarantee! NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/41°F and 35°C/95°F. Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your dealer about the way to proceed. The specifications are typical. The actual values can slightly change from one unit to the other. Specifications can be changed without prior notice. Do not attempt to make any repairs yourself. This would invalid your warranty. Do not make any changes to the unit. This would also invalid your warranty. The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the warnings contained in this manual. Vonyx cannot be held responsible for personal injuries caused by a disrespect of the safety recommendations and warnings. This is also applicable to all damages in whatever form. 4 UNPACKING INSTRUCTION CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing materials. In the event that the product must be returned to the factory, it is important that the product be returned in the original factory box and packing. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. POWERSUPPLY On the label on the backside of the product is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used. No dimmer or adjustable power supply. Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate electrical ground to avoid the risk of electrocution or fire. CONTROLS AND CONNECTIONS 1. Microphone Input(s) 6.3mm ¼” input jack (and XLR jack for 170.342 and 170.343 only) for connecting a microphone. 2. Line inputs XLR and RCA jack input for connecting audio units with line level output (e.g. mixer, CD player) 3. Line output(s) XLR output jack (and 6.3mm (¼”) jack for 170.342 and 170.343 only) for connecting an extra active speaker or audio unit with line level input. 4. Microphone Level Adjust the signal level of microphone. 5. Line Level Adjust the signal level of line input. 6. Master volume Adjust the overall output level of the portable sound set. 7. Treble Adjust high tone control. 8. Bass Adjust high low tone control. 9. Clip Indicator Indicator lights up when signal level is too high. When the LED light up continually you must reduce the volume to protect the speaker. 10. Power Indicator Indicator lights up when power turned on Noted: Passive speaker output connector, minimum load 8 Ohm!

AP800A: Related Instructions

Manuals from Other Manufacturers