Weinzierl KNX IP LineMaster 762 Manuals

1 pdf manual(s) Weinzierl KNX IP LineMaster 762 for free download (Document Types: Operation and installation manual)

Weinzierl KNX IP LineMaster 762 Operation and installation manual [PDF] (8 pages)

  • Identifier: id-1380884
  • Brand: Weinzierl
  • Device: KNX IP LineMaster 762 Power Supply
  • Type: PDF
  • Key Aspects: Regulatory Compliance and Standards, Device Specifications Overview, Best Practices for Everyday Use
  • UPD Date: 03.08.2026
  • Source File: 1346870.pdf
  • Pages: 8
  • Description: Operation guide for the Weinzierl KNX IP LineMaster 762.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
©2017 WEINZIERL ENGINEERING GmbH Page 1/8 Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions KNX IP LineMaster 762 Application The KNX LineMaster 762 combines the essential functions of a KNX bus line: Power supply with choke, KNX IP Router and KNX IP Interface with a small footprint of only 6 units (108 mm). The KNX IP Router in the KNX IP LineMaster 762 allows for- warding of telegrams between different lines through a LAN (IP) as a fast backbone. In addition this device is suited to connect a PC to the KNX network e.g. for ETS® programming. The IP address can be obtained by a DHCP server, by manual configuration via the device menue or by downloading a config- ured ETS application. This device works according to the KNXnet/IP specification using the core, the device management, the tunneling and the routing part. The KNX IP LineMaster 762 has a filter table (8 kByte) and is able to buffer up to 150 telegrams. An easy to read OLED display on the front panel enables the user to display the operating parameters locally on the device. Coupler function (KNXnet/IP Routing) The KNX IP LineMaster 762 operates as a line or backbone cou- pler. In both cases, the LAN (IP) is used as a backbone. The following table shows the application possibilities of the KNX IP LineMaster 762 compared to the classic topology: Classical Topology (without IP) IP coupling of areas (IP area coupl.) IP coupling of lines (IP line coupler) Area (Backbone) TP IP IP Coupling KNX Line Coupler (max. 15 Pcs.) KNX IP Router (max. 15 Pcs.) Directly via LAN Switch Main line TP TP IP Coupling KNX Line Coupler (max. 15x15 Pcs.) KNX Line Coupler (max. 15x15 Pcs.) KNX IP Router (max. 225 Pcs..) Line TP TP TP KNX IP LineMaster 762 as line coupler The individual address assigned to the KNX IP LineMaster 762 determines whether the device operates as a line or area cou- pler. If the individual address is in the form of x.y.0 (x, y: 1..15), the KNX IP LineMaster 762 operates as a line coupler. If it is in the form of x.0.0 (x: 1..15), the KNX IP LineMaster 762 acts as a backbone coupler. KNX IP LineMaster 762 as area coupler If the KNX IP LineMaster 762 is used as an area coupler (x.0.0), there must not be a KNX IP Router in the topol- ogy beneath it. For example, if a KNX IP Router has the individual address 1.0.0, there must be no KNX IP Router with the address 1.1.0. If the KNX IP LineMaster 762 is used as a line coupler (x.y.0), there must not be a KNX IP Router in the topol- ogy above it. For example, if a KNX IP Router has the in- dividual address 1.1.0, there must be no KNX IP Router with the address 1.0.0. Switch KNX LAN 1.1.1 1.1.6 1.1.5 1.1.4 1.1.3 1.1.2 1.1.7 1.1.12 1.1.11 1.1.10 1.1.9 1.1.8 KNX IP LineMaster 762 1.1.0 KNX IP LineMaster 762 2.1.0 KNX 2.1.1 2.1.6 2.1.5 2.1.4 2.1.3 2.1.2 2.1.7 2.1.12 2.1.11 2.1.10 2.1.9 2.1.8 Switch LAN KNX IP LineMaster 762 1.0.0 KNX IP LineMaster 762 2.0.0 KNX 1.1.0 1.2.0 1.2.1 1.2.6 1.2.5 1.2.4 1.2.3 1.2.2 1.1.1 1.1.6 1.1.5 1.1.4 1.1.3 1.1.2 KNX 2.1.0 2.2.0 2.2.1 2.2.6 2.2.5 2.2.4 2.2.3 2.2.2 2.1.1 2.1.6 2.1.5 2.1.4 2.1.3 2.1.2 EN