Wellsys WS 12000 Manuals
1 pdf manual(s) Wellsys WS 12000 for free download (Document Types: Instructions)
Wellsys WS 12000 Instructions [PDF] (4 pages)
- Identifier: id-2086630
- Brand: Wellsys
- Device: WS 12000 Dispenser
- Type: PDF
- Key Aspects: Device Specifications Overview, Best Practices for Everyday Use, Efficiency and Calibration Tips
- UPD Date: 27.07.2026
- Source File: 2201226.pdf
- Pages: 4
- Description: Complete usage guide for the Wellsys WS 12000.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Step 1: Remove all 9 screws circled above. Then remove the top & rear panel. Step 2: Remove the two screws indicated above and remove the front panel. Step 3: Peel back insulation to expose the 'ice making' sensor and the 'ice full' sensor receive. Step 4: Remove everything from the upper front half of the holding tank. Step 5: Remove the two screws located on the holding tank, just behind the panel. --------------------------------------- Phillips head screw driver TDS meter Microfiber towels & paper towels Gloves 5 gallon bucket Thermometer Tubing & tube cutters Pledge multi-surface Hydrogen Peroxide You will need: WS 12000 Annual PM Guide The WS 12000 Unit needs preventative maintenance every year. Follow the instructions below for appropriate instructions. Step 6: Carefully remove the Styrofoam bin lid. Part 1: Sanitizing the Unit Pre-Sediment Filter (ICESEO): 1 year or 2500 gallons max Pre-Carbon Filter (ICEPREC): 1 year or 2500 gallons max Reverse Osmosis (ICERO): 3 years or 4500 gallons max TCR Filter (ICEPOSTCA): 3 years or 2500 gallons max Filter Change Regime: What to do: