WESTEK TE1606 Manuals
1 pdf manual(s) WESTEK TE1606 for free download (Document Types: Instruction manual)
WESTEK TE1606 Instruction manual [PDF] (2 pages)
- Identifier: id-2383440
- Brand: WESTEK
- Device: TE1606 Timer
- Type: PDF
- Key Aspects: Unpacking and Inspection Guidelines, Device Specifications Overview, Storage and Care Recommendations
- UPD Date: 24.06.2026
- Source File: 2421351.pdf
- Pages: 2
- Description: Manual for safe operation of the WESTEK TE1606.
Click to expand and read text
{Westek. TE1606WHB INDOOR DIGITAL WEEKLY TIMER Instruction Manual & Warranty LCD Display Nomenclature: 1 2 3 Alll ifO TU r.JE1 TII m SA 00 ��f dJS:dJS �� fB o [[J IQlST tID OIM A JO OFF 7 6 5 Nole: Not all functions are available on each timer. 1. AM/PM will appear when 12-hour is set 2. MO to SU stand for Monday, Tuesday, Wednesday. Thursday, Friday, Saturday and Sunday 3. Hour:Minute:Second 4. R will appear when Random mode is enabled 5. Manual/ Auto mode. AUTO OFF, the device is in Timer Mode and remains off until the first ON setting in programs AUTO ON. the device is in Timer Mode and remains on unfi the first OFF setting in programs ON, timer remains on, and will not run any program until override key is pressed and AUTO is displayed OFF, timer remains off, and wiM not run any program until override key is pressed and AUTO is displayed 6. CTD will appear when countdown is enabled. 7. DSTwil appear when day light saving enabled 8. D2D will appear when Dusk to Dawn enabled. 9. Program#, up to 20 programs are available l O. ON/OFF indicate the output status Before using your timer for the first lime, please read the instructions carefully. TEl 606WHB Features 20 programmable ON/OFF settings per week 12 hour AM/PM or 24 hour display Programmable in l minute intervals Daylight Saving Time setting Count Down Timer Random ON/OFF Feature (2-30 minutes of programmed time) Manual override - temporarily or permanently overrides current program Key Functions SET: Selects and confirms the program setting. DOWN/UP: Increase or decrease day and digit settings. Also used to enable the Count Down function by pressing and holding DOWN/UP together. ON/OFF: Anows user to select On, Off or Auto. Can be used for manual override of timer settings without losing programming. RND: Press Random ON/OFF setting to activate random delay for start or finish of ON periods. RESET: Use a pencil or paper clip to press the reset key to initiate programming. The timer clock must be set before programming any On/Off settings. Selling the current lime 1. If display does not appear, plug unit into a receptacle and charge the internal battery for 1 hour. 2. Remove the unit from the receptacle and press the RESET key to begin programming. 3. Press and hold the ON/OFF key, then press the DOWN key to toggle between 12 or 24 hour display. AM wiD appear on the display when 12 Hour display is selected. 4. Press and hold the ON/OFF key, then press the UP key to toggle between normal and Daylight Savings Time. DST will appear on the display, one hour ahead of the current time. Press the UP key again to again to cancel DST. 5. Press and hold SET key for 3 seconds ,the "MO" flashes on display, using DOWN or UP keys to select the current day, press the SET key again to confirm your selection. 6. Hour digits flash on display, using DOWN or UP keys to select current hour, press SET key again to confirm. 7. Minute digits flash on display, using DOWN or UP keys to select current minute, press SET key again to confirm. There is no option to set the Seconds. Note: If programming is interrupted for more than 30 seconds while setting the tirne, the unit will automatically revert to default mode. Preset time will be preserved. Programming ON/OFF Events (maximum 20 events) Note: If a programming step is interrupted for more than 30 seconds, unit will automatically revert to default mode. Press Reset to start the process over. 1. Clock time must be set before programming ON/OFF times. 2. After clock has been set, press the UP key. 3. Press the SET key to edit l ON program. Use the UP or DOWN keys to cycle through the days of the week selections. Options l. Individual day of the week 2. MO TU WE TH FR SA SU (Every day) 3. MO TU WE TH FR (Weekdays only) 4. SA SU {Weekends only) 5. MO TU WE TH FR SA 6.MO WE FR 7.TU TH SA 8.MO TU WE 9. TH FR SA 10. MO WE FR SU Press the SB key again to confirm your selecHon. 4. Next the Hour digits will flash on the display, use the DOWN or UP keys to select the starting hour. Press the SET key again to confirm your selection. 5. Next the Minute digits will flash on the display, use the DOWN or UP keys to select the starting minute. Press the SET key again to confirm your selection. Next the program 1 OFF setting needs to be programmed. 6. Press UP key to enter 1 OFF editing. 7. Repeat steps 3 thru 5 to set day(s) and enter the day and time the device should turn OFF. 8. To set additional ON/OFF cycles, (maximum 20 events), press UP key. Then press UP or DOWN keys and follow procedures in steps 3 thru 5 for each new ON/OFF event. When finished, press UP or DOWN keys to exit , or wait for 1 minute (30 seconds to exit interface of edit timing, 30 seconds to exit interface of program event) - Note 1: Programming of switching times (ON/OFF) will not work properly if 'program ON' overlaps with 'program OFF' Note 2: If programming is interrupted for more than 30 seconds whie setting program, unit will automatically revert to default mode. Preset time will be preserved. Deleting Programs 1. Press UP key. Use UP or DOWN keys to select ON/OFF event to be deleted. 2. Press ON/OFF key to delete program setting. Press again to restore. 3. When done, press UP or DOWN keys to exit ,or wait for 1 minute (30 seconds to exit interface of edit timing, 30 seconds to exit interface of program event) Random Function Tums On after 2-30 minutes of your programmed ON settings, turns Off before 2-30 minutes of your programmed Off settings . To activate Random Function, press RND button until "R" appear on display. Press again to cancel. Setting the Random Function will affect all 20 Programs. Note: Programming of switching times (ON/OFF) will not work properly if 'program ON' overlaps with 'program OFF' Manual Override The ON/OFF key can be used to switch ON or OFF. Repeated pressing of the ON/OFF key causes scrolling from AUTO OFF(default)-MANUAL ON-AUTO ON-MANUAL OFF-AUTO OFF. AUTO OFF, the device is in Timer Mode and remains off until the first ON setting in programs AUTO ON, the device is in Timer Mode and remains on until the first OFF setting in programs ON, timer remains on , and will not run any program until override key is pressed and AUTO is displayed OFF, timer remains off , and will not run any program until ovenide key is pressed and AUTO is displayed Count Down On/Off Selling 1. Press UP or DOWN key for 3 seconds to enter "CTD" setting interface 2. Press SET key ,OFF flashes on display ,use DOWN or UP keys to select ON or OFF, press SET key to confirm. OFF option, keep timer on and turn timer off when CTD finished ON option, keep timer off and tum timer on when CTD finished. 3. Hour digits flash on display ,Use DOWN or UP keys select hour{s), press SET key to confirm. 4. Minute digits flash on display, using DOWN or UP keys to select minute, press SET key to confirm. 5. Seconds digits flash on display, using DOWN or UP keys to select seconds, press SET key to confirm. 6. Press CTD key to start count down, press CTD key again to stop count down. TI mer will keep the status before CTD stopped. Notel: If you are at the current time display, press CTD key ,it will start count down too , CTD on display will flash and ON/OFF will indicate the status of current timer output. Note2: If programming is intenupted for more than 30 seconds whYe setting CTD, unit will automatically revert to default mode. Preset time will be preserved. Reset key Press RESET key. limer wiM resume in default status. All time and program information will be lost. Programming priorities are Manual ON/OFF>Random>CTD>Programmed events RATINGS: 125V, 60Hz l 0A, 1250W Resistive 8A, 1000W Tungsten 1/4HP One-Year Limited Warranty . . �:J:i=s�d:5�1��; g{��! ;:d s ; ::;������d��of�::e��'Jtti�al details are available at www.amertac.com. Prop. 65 Warning: This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Garantie limitee de 1 an Amer Tac garantit a l'acheteur initial que, dans des conditions normales d'utilisation, ce produit sera exempt de defaut de m��riaux et _de fabr!cation pe�dant_une period� de 1 an a compter de la date d'adiat Des details supplementa1res sont d1spornbles sur le site www.amertac.com. Garantfa Limitada de 1 Afio Amer Tac le garantiza al comprador original que este producto estara libre de clefectos en materiales y mano de obra por un perfodo de 1 afio a partir de la fecha de oompra. Detalles adicionales disponibles a traves de www.amertac.com. AmerTac 250 Boulder Dr. Breinigsville, PA 18031 610-336-1330 www.amertac.com Made In China ©2017 AmerTacTM I17-001B-A c�us lntertek 3160817 CONFORMS TO UL STD 60730-1, 60730-2-7 CERTIFIED TO CSA STD E60730--1,E730-2-7 CUMPLE LA NORMA UL 60730-1, 60730-2-7 CERTIFICADO SEGUN LA NORMA CSA E60730--1,E730-2-7 CONFORME A. LA NORME UL STD 60730--1, 60730-2-7 CERTIFIE CONFORMl:MENT A LA NORME CSA STD E60730--1,E730-2-7
WESTEK TE1606: Timer Category Related Instructions
Maintenance instructions for the Autonics LE3S Series Timer. It offers details on operational procedures, shutdown procedures, troubleshooting.
No.3951 (Punch card during power failure) No.3952 (Do not punch card during power failure) -------------------------------------------------------------------------------------------------------- Microcomputer Time Recorder Instruction Manual ----------------- Installation and operation manual for the Delimano 3951 Timer. This manual covers daily usage, maintenance guidelines, backup procedures.
FP715Si Electronic 2-Channel Full Programmer for Heating and Hot Water with Service Interval Timer Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE Full operation manual for the Danfoss FP715Si Controller. It explains installation, setup, and user instructions, startup procedures, dimensions and layout.
GAMMa wave Technical Product Information March 2008 DELTA i-system Pushbutton wave shutter UP 211 5WG3 211-2HB_1 DELTA profil Pushbutton wave shutter UP 211 5WG3 211-2AB_1 DELTA style Pushbutton wave shutter UP 211 5WG3 211-2GB_1 Siemens AG Pushbutton wave shu Stepwise user guide for the Siemens DELTA i-system Controller. This guide presents maintenance, performance details, firmware updates.