Wheelock NS-1215W Manuals
1 pdf manual(s) Wheelock NS-1215W for free download (Document Types: Installation instructions manual)
Wheelock NS-1215W Installation instructions manual [PDF] (10 pages)
- Identifier: id-247739
- Brand: Wheelock
- Device: NS-1215W Smoke Alarm
- Type: PDF
- Key Aspects: Standard Operating Procedures, Glossary of Technical Terms, Storage and Care Recommendations
- UPD Date: 05.09.2026
- Source File: 192561.pdf
- Pages: 10
- Description: Instructions for safe usage of the Wheelock NS-1215W.
Click to expand and read text
P84030 D Sheet 1 of 10 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS SERIES NS TWO WIRE APPLIANCES (WALL MOUNT VERSIONS) Use this product according to this instruction manual. Please keep this instruction manual for future reference. GENERAL: Wheelock’s Series NS Horn Strobe Appliances require only 2-wires for operation of the horn and strobe appliance and provide a selectable continuous or Code 3 Horn tone and continuous strobe when connected directly to the Fire Alarm Control Panel (FACP). They can also provide a synchronized Code 3 horn tone and synchronized strobe when used in conjunction with a Sync Module (SM), Dual Sync Module (DSM) or Power Supply (PS-12/24-8). They are the ideal choice for applications where the audible silence feature is required. The NS Appliances are UL Listed under Standard 1971 for Signaling Devices for the Hearing Impaired and UL Standard 464 for Audible Signal Appliances. They are listed for indoor use only and equipped with a NS Mounting Plate (NSMP) that can be mounted to single-gang, double-gang, 4” backbox, 100mm European backbox or SHBB surface backbox (See Mounting Options). These strobe models are Listed for wall mounting only. The NS Appliances use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum visibility and reliability for effective visible signaling. Series NS Appliances can be field set for High (HI) or Low (LO) dBA sound output. These strobe models are designed for use with either filtered DC (VDC) or unfiltered Full-Wave-Rectified (FWR) input voltage. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a FACP. NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. SPECIFICATIONS: Table 1: UL Ratings Models Regulated Voltage (VDC/VRMS) Voltage Range (VDC/VRMS) Strobe Candela (cd) NS-2415W 24 16.0-33.0 15 NS-2430W 24 16.0-33.0 30 NS-2475W 24 16.0-33.0 75 NS-24110W 24 16.0-33.0 110 NS-1215W 12 8.0-17.5 15 WARNING: THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 16-33 VOLTS FOR 24V MODELS AND 8-17.5 VOLTS FOR 12V MODELS USING FILTERED (DC) OR UNFILTERED FULL-WAVE- RECTIFIED (FWR). DO NOT APPLY 80% AND 110% OF THESE VOLTAGE VALUES FOR SYSTEM OPERATION. NOTE: THE MAXIMUM WIRE IMPEDENCE BETWEEN STROBES SHALL NOT EXCEED 35 OHMS. THE MAXIMUM NUMBER OF STROBES ON A SINGLE NAC CIRCUIT SHALL NOT EXCEED 47. Copyright 2001 Wheelock, Inc. All rights reserved.
Wheelock NS-1215W: Smoke Alarm Category Related Instructions
Thank you for choosing Setup of Smoke Detector Location test and mounting instruction Asante Smoke Detector battery compartment and buttons 1. Remove the base from the smoke detector 2. Insert battery into smoke detector and close the lid. Inside the battery c Product operation guide for the Asante Smoke Detector Smoke Alarm. This manual covers technical troubleshooting, software installation, replacement parts.
Product usage manual for the AKCP SK00 Smoke Alarm. The manual guides users through safety information, system configuration, compatibility information, safety features.
Instruction guide for the Honeywell DFS8M Smoke Alarm. The manual provides technical details on system parameters, maintenance guidelines, power management, performance details.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVED NNU5-1_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security. Redun Owner’s manual for the LST NNU5-1 Smoke Alarm. It explains troubleshooting and menu navigation, replacement parts, startup procedures.