Wheelock RSS-1215W Manuals

1 pdf manual(s) Wheelock RSS-1215W for free download (Document Types: Installation instructions manual)

Document Preview & Text Transcription

P84022 F Sheet 1 of 6 273 Branchport Ave. Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS SERIES RSS AND RSSP STROBE APPLIANCES (WALL MOUNT VERSIONS) Use this product according to this instruction manual. Please keep this instruction manual for future reference. GENERAL: Wheelock’s Series RSS and RSSP Strobes can provide a non-synchronized strobe appliance when connected directly to a Fire Alarm Control Panel (FACP), or provide a synchronized strobe appliance when used in conjunction with a Sync Module (SM), Dual Sync Module (DSM) or Power Supply (PS-12/24-8). The Series RSS and RSSP Strobe Appliances are UL Listed under Standard 1971 (Signaling Devices for the Hearing Impaired) for indoor fire protection service. These Strobes are listed for wall mount only, with the backboxes specified in these instructions (See Mounting Options). RSS models have an integrated Strobe Mounting Plate (SMP) that can be mounted to a single-gang, double-gang, 4” backbox, 100mm European backbox or SHBB surface backbox. The strobes use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum visibility and reliability for effective visible signaling. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by the FACP. NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: THE RSS STROBE APPLIANCE IS A "FIRE ALARM DEVICE - DO NOT PAINT." WARNING: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. SPECIFICATIONS: Table 1: Ratings Per UL 1971 Model Regulated Voltage VDC/VRMS Voltage Range Limit VDC/VRMS Strobe Candela (CD) Mounting Options RSS-2415W 24 16.0-33.0 15 A,B,C,D RSSP-2415W 24 16.0-33.0 15 E,F RSS-2430W 24 16.0-33.0 30 A,B,C,D RSSP-2430W 24 16.0-33.0 30 E,F RSS-2475W 24 16.0-33.0 75 A,B,C,D RSSP-2475W 24 16.0-33.0 75 E,F RSS-24110W 24 16.0-33.0 110 A,B,C,D RSSP-24110W 24 16.0-33.0 110 E,F RSS-1215W 12 8.0-17.5 15 A,B,C,D RSSP-1215W 12 8.0-17.5 15 E,F NOTE: THE MAXIMUM WIRE IMPEDANCE BETWEEN STROBES SHALL NOT EXCEED 35 OHMS. THE MAXIMUM NUMBER OF STROBES ON A SINGLE NOTIFICATION APPLIANCE CIRCUIT SHALL NOT EXCEED 47. WARNING: THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 16-33 VOLTS FOR 24V MODELS AND 8-17.5 VOLTS FOR 12V MODELS USING FILTERED (DC) OR UNFILTERED FULL-WAVE RECTIFIED (FWR). DO NOT APPLY 80% AND 110% OF THESE VOLTAGE VALUES FOR SYSTEM OPERATION. WARNING: CHECK THE MINIMUM AND MAXIMUM OUTPUT OF THE POWER SUPPLY AND STANDBY BATTERY AND SUBTRACT THE VOLTAGE DROP FROM THE CIRCUIT WIRING RESISTANCE TO DETERMINE THE APPLIED VOLTAGE TO THE STROBES. Copyright 2001 Wheelock, Inc. All rights reserved. Table 1A. Audibles/Speakers for RSSP Strobe/Plate Product Series Multitone Appliances AMT, MT, MT4 Motor Bells MB-G6/G10 Speakers ET-1010/1070/1080, ET70, E7025/7070, E70 Chimes CH70 NOTES: 1. Strobes will produce 1 flash per second over the “Regulated Voltage” range. 2. All models are UL Listed for indoor use with a temperature range of +32oF to +120oF (0oC to +49oC) and maximum humidity of 85% RH. P84022 F Sheet 2 of 6 Table 2A: Current Ratings (AMPS) for 24VDC Models Rated Average Current Voltage 2415W 2430W 2475W 24110W MEAN RMS MEAN RMS MEAN RMS MEAN RMS 16.0VDC 0.072 0.090 0.125 0.143 0.215 0.257 0.276 0.327 24.0VDC 0.053 0.079 0.085 0.113 0.140 0.200 0.169 0.256 33.0VDC 0.045 0.072 0.069 0.103 0.114 0.174 0.138 0.228 16.0VRMS ----- 0.105 ----- 0.141 ----- 0.262 ----- 0.330 24.0VRMS ----- 0.076 ----- 0.121 ----- 0.211 ----- 0.262 33.0VRMS ----- 0.070 ----- 0.105 ----- 0.185 ----- 0.229 Rated Peak Current * Voltage 2415W 2430W 2475W 24110W 16.0VDC 0.185 0.264 0.456 0.584 24.0VDC 0.190 0.269 0.470 0.586 33.0VDC 0.195 0.274 0.474 0.596 16.0VRMS 0.182 0.259 0.458 0.586 24.0VRMS 0.185 0.268 0.472 0.590 33.0VRMS 0.197 0.286 0.492 0.596 Rated Inrush Current ** Voltage 2415W 2430W 2475W 24110W 16.0VDC 0.110 0.110 0.110 0.110 24.0VDC 0.165 0.165 0.165 0.165 33.0VDC 0.230 0.230 0.230 0.230 16.0VRMS 0.155 0.155 0.155 0.155 24.0VRMS 0.235 0.235 0.235 0.235 33.0VRMS 0.325 0.325 0.325 0.325 Table 2B: Current Ratings (AMPS) for 12VDC Models Rated Average Current Voltage 1215W MEAN RMS 8.0VDC 0.220 0.246 12.0VDC 0.129 0.187 17.5VDC 0.099 0.163 8.0VRMS ----- 0.246 12.0VRMS ----- 0.198 17.5VRMS ----- 0.170 Rated Peak Current * Voltage 1215W 8.0VDC 0.410 12.0VDC 0.426 17.5VDC 0.438 8.0VRMS 0.414 12.0VRMS 0.426 17.5VRMS 0.444 Rated Inrush Current ** Voltage 1215W 8.0VDC 0.081 12.0VDC 0.100 17.5VDC 0.145 8.0VRMS 0.098 12.0VRMS 0.140 17.5VRMS 0.190 * Rated average current is measured using mean value. ** The time duration for the peak current is 100 microseconds. *** The time duration for the inrush current is 4 milliseconds. WARNING: MAKE SURE THAT THE TOTAL AVERAGE CURRENT, TOTAL PEAK CURRENT AND TOTAL INRUSH CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM’S PRIMARY AND SECONDARY POWER SOURCES, NAC CIRCUITS, SM, DSM SYNC MODULES OR PS-12/24-8 POWER SUPPLY DO NOT EXCEED THE POWER SOURCES’ RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED. OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. P84022 F Sheet 3 of 6 When calculating the total average, peak or inrush currents: Use Table 2A and 2B to determine the highest value of “Rated Average Current” for an individual strobe (across the expected operating voltage range of the strobe) to determine the highest value of “Rated Inrush Current” or “Rated Peak Current” (whichever is higher) of an individual strobe (across the expected voltage range of the strobe) then multiply the value by the total number of strobes; be sure to add the currents for any other appliances, including audible signaling appliances, powered by the same source and include any required safety factors. If the inrush current or peak current exceeds the power supplies’ inrush capacity, the output voltage provided by the power supplies may drop below the listed voltage range of the appliances connected to the supply and the voltage may not recover in some types of power supplies. For example, an auxiliary power supply that lacks filtering at its output stage (either via lack of capacitance and/or lack of battery backup across the output) may exhibit this characteristic. CAUTION: Strobes are not designed to be used on coded systems in which the applied voltage is cycled on and off. LIGHT DISTRIBUTION: Table 3: Horizontal Plane Horizontal 15W 30W 75W 110W Angle (in deg.) UL Min. Typ. 15W UL Min. Typ. 30W UL Min. Typ. 75W UL Min. Typ. 110W 0 15.0 24 30.0 46 75.0 103 110.0 149 5 13.5 24 27.0 46 67.5 103 99.0 152 10 13.5 24 27.0 45 67.5 104 99.0 151 15 13.5 24 27.0 46 67.5 100 99.0 151 20 13.5 23 27.0 43 67.5 101 99.0 148 25 13.5 23 27.0 43 67.5 98 99.0 140 30 11.3 21 22.5 41 56.3 94 82.5 135 35 11.3 20 22.5 40 56.3 89 82.5 129 40 11.3 19 22.5 39 56.3 83 82.5 124 45 11.3 18 22.5 41 56.3 81 82.5 133 50 8.3 18 16.5 36 41.3 77 60.5 121 55 6.8 12 13.5 27 33.8 60 49.5 85 60 6.0 11 12.0 30 30.0 59 44.0 95 65 5.3 13 10.5 35 26.3 71 38.5 113 70 5.3 17 10.5 29 26.3 73 38.5 81 75 4.5 13 9.0 22 22.5 53 33.0 72 80 4.5 8 9.0 17 22.5 35 33.0 50 85 3.8 7 7.5 15 18.8 30 27.5 38 90 3.8 6 7.5 15 18.8 30 27.5 43 Table 3A: Vertical Plane Vertical 15W 30W 75W 110W Angle (in deg.) UL Min. Typ. 15W UL Min. Typ. 30W UL Min. Typ. 75W UL Min. Typ. 110W 0 15.0 24 30.0 46 75.0 103 110.0 149 5 13.5 24 27.0 46 67.5 103 99.0 149 10 13.5 24 27.0 46 67.5 103 99.0 137 15 13.5 24 27.0 45 67.5 102 99.0 120 20 13.5 24 27.0 41 67.5 104 99.0 110 25 13.5 21 27.0 48 67.5 89 99.0 129 30 13.5 23 27.0 40 67.5 96 99.0 114 35 9.8 22 19.5 45 48.8 91 71.5 119 40 6.9 13 13.8 39 34.3 57 50.6 109 45 5.1 9 10.2 24 25.5 36 37.4 66 50 4.0 9 8.1 16 20.0 33 29.7 45 55 3.3 8 6.6 15 16.3 31 24.2 43 60 2.7 8 5.4 15 13.5 31 19.8 40 65 2.4 8 4.8 14 12.0 31 17.6 40 70 2.3 8 4.5 15 11.3 31 16.5 39 75 2.0 8 4.0 14 10.0 31 14.3 39 80 1.8 8 3.6 13 9.0 27 13.2 36 85 1.8 7 3.6 13 9.0 27 13.2 37 90 1.8 3 3.6 9 9.0 12 13.2 16