YOKOGAWA 2560A Manuals
2 pdf manual(s) YOKOGAWA 2560A for free download (Document Types: Operation & user’s manual)
YOKOGAWA 2560A Operation & user’s manual [PDF] (9 pages)
- Identifier: id-1420875
- Brand: YOKOGAWA
- Device: 2560A Test Equipment
- Type: PDF
- Key Aspects: Information on Regular Maintenance, Technical Data and Parameters, Component Overview and Descriptions
- UPD Date: 28.04.2026
- Source File: 1577569.pdf
- Pages: 9
- Description: Device technical manual for the YOKOGAWA 2560A.
Click to expand and read text
User’s Manual IM 2560A-71EN 1/9 2nd Edition 2nd Edition : October 2017 (YMI) All Rights Reserved, Copyright © 2015, Yokogawa Test & Measurement Corporation Printed in Japan Model 2560A Precision DC Calibrator Simple Adjustment Procedure Have a qualified engineer perform simple adjustment of the 2560A at a specialized facility with sufficient precision. The simple adjustment values are retained even when the settings are initialized. If you need to adjust the 2560A more accurately than that is possible with the simple adjustment feature or if you want calibration and adjustment to be performed at a YOKOGAWA factory, contact your nearest YOKOGAWA dealer. If calibration and adjustment are performed at a YOKOGAWA factory, all settings will be initialized to their factory default values including the simple adjustment values. WARNING •� Ground�the�instrument�before�connecting�the�instrument�to�the�target�device.�The�power�cord� that comes with the instrument is a three-prong type power cord. Insert the power cord into a grounded three-prong outlet. •� Be�sure�to�turn�off�the�output�before�connecting�or�disconnecting�the�target�device. French AVERTISSEMENT •� Relier�l’instrument�à �la�terre�avant�de�le�brancher�sur�l’appareil�cible.�Le�cordon�d’alimentation� livré�avec�l’instrument�est�doté�de�trois�broches.�Brancher�le�cordon�d’alimentation�sur�une� prise�de�courant�à �trois�plots�mise�à �la�terre.� •� Toujours�mettre�hors�tension�avant�de�brancher�ou�de�débrancher�l’appareil�cible. In addition to the above items, be sure to observe the warnings and precautions provided in the�“Wiring�Precautions��and�“Connecting�Wires��sections�in�the�2560A�User’s�Manual,�IM� 2560A-01EN. Required Equipment and Components •� Digital�multimeter�(DMM)� Keysight�Technologies�3458A�or�equivalent •� Standard�0.1�Ω�and�10�Ω�resistors� �Yokogawa�Test�&�Measurement�Corporation�2792A03�and�2792A05,�or� equivalents •� Standard�temperature�device� Coper�Electronics�ZC-114A�or�equivalent •� Thermocouple�type�K� JIS�C1602�or�IEC�60584-1�compliant�product •� DC�current�sensor� Yokogawa�Test�&�Measurement�Corporation�CT200�or�equivalent Each piece of equipment and component must be calibrated and with sufficient precision. Adjustment Conditions •� Ambient�temperature:�23°C�±�2°C,�humidity:�20%RH�to�60%RH�(no�condensation),�warm-up�time:�at�least�60� minutes •� Permitted�supply�voltage�range:�90�VAC�to�132�VAC�and�180�VAC�to�264�VAC,�permitted�supply�frequency� range:�48�Hz�to�63�Hz •� For�100�mV�and�thermocouple�adjustment�ranges�of�the�2560A,�perform�adjustment�with�the�2560A�output� terminal�temperature�balanced�and�stable.�During�adjustment,�be�careful�in�keeping�the�output�terminal� temperature from changing. •� Set�the�DMM’s�integration�time�(NPLC)�to�100PLC�or�longer. * NPLC:�An�acronym�for�Number�of�Power�Line�Cycles.�It�is�a�way�of�expressing�the�integration�time. Wiring The 2560A and equipment are wired according to each function, namely voltage, current, thermocouple, resistance,�and�internal�RJC. For�the�wiring�diagrams,�see�the�wiring�examples�in�the�later�“Explanation��section. After�wiring,�operate�the�2560A�according�to�the�procedure�on�the�next�page.
YOKOGAWA 2560A Operation & user’s manual [PDF] (199 pages)
- Identifier: id-1631365
- Brand: YOKOGAWA
- Device: 2560A Test Equipment
- Type: PDF
- Key Aspects: User Training Recommendations, System Limitations and Considerations, Product Performance Metrics
- UPD Date: 27.05.2026
- Source File: 1687364.pdf
- Pages: 199
- Description: Complete device guide for the YOKOGAWA 2560A.
Click to expand and read text
IM 2560A-01EN 3rd Edition Precision DC Calibrator 2560A
YOKOGAWA 2560A: Test Equipment Category Related Instructions
LLT Live Line Tester Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co. Durham SR8 2SW ENGLAND Tel: +44 (0)191 586 3511 www.seaward.co.uk [email protected] [email protected] Part Number 114A556 Revision 1 © 2007 Seaward Electr Instruction guidebook for the Seaward Live Line Tester Test Equipment. This manual provides information on installation support, component replacement, safety.
Lovibond® Water Testing Tintometer® Group Turbidimeter TB 350 EN Quick Start Guide....................3 DE Kurzanleitung........................ 28 ES GuÃa de inicio rápido.............54 FR Guide de démarrage rapide......................................8 Official product manual for the Lovibond Tintometer TB 350 Test Equipment. It outlines the setup and operational procedures, performance optimization, control functions.
Dual Range Tester – R18 The tracER - A dual range tester for semiconductors and other components. Introduction The Electro resales tracER is a modern implementation of a testing device developed originally to assist service professionals who had access to an Installation guide for the Electro tracER-A Test Equipment. The document provides guidance on safety and setup tips, cleaning instructions, performance details, replacement parts.
For Main Firmware Version 1.90 Calibrating and Adjusting MC5 / 011912 Calibration and Adjustment Instructions for MC5 Multifunction Calibrator Enable Adjustment Mode Select Quantity and Function/Port Calibrate (Compare against a more accurate instrument) Adjus Device instruction manual for the BEAMEX MC5 Test Equipment. This guide presents instructions on device calibration, repair references, interface navigation, device overview.