YOKOGAWA DpharpEJX vigilantplant EJX Series Manuals

3 pdf manual(s) YOKOGAWA DpharpEJX vigilantplant EJX Series for free download (Document Types: Manual , Operation & user’s manual)

Available Documents for DpharpEJX vigilantplant EJX Series:

YOKOGAWA DpharpEJX vigilantplant EJX Series Manual  Main Page Preview

Manual  [PDF] (45 pages)

  • Brand: YOKOGAWA
  • Model: DpharpEJX vigilantplant EJX Series
  • Format: PDF
  • Key Aspects: Basic Configuration Guidelines, System Architecture and Design Overview, Model Variations and Compatibility
  • Updated: 14.07.2026
  • Source File: 147757.pdf
  • Pages: 45
  • Description: Product operation guide for the YOKOGAWA DpharpEJX vigilantplant EJX Series.

Document Preview & Text Transcription

User’s Manual Yokogawa Electric Corporation EJX Series HART Communication Type IM 01C25T01-01E IM 01C25T01-01E 3rd Edition i IM 01C25T01-01E CONTENTS FD No. IM 01C25T01-01E 3rd Edition: Oct. 2004 (YK) All Rights Reserved, Copyright © 2004, Yokogawa Electric Corporation CONTENTS 1. INTRODUCTION .......................................................................................... 1-1 Regarding This Manual ................................................................................. 1-1 1.1 Safe Use of This Product.................................................................... 1-2 1.2 Warranty .............................................................................................. 1-2 1.3 ATEX Documentation.......................................................................... 1-3 1.4 Matching of Communicator DD and Instrument DD ........................... 1-4 2. CONDITIONS OF COMMUNICATION LINE............................................... 2-1 2.1 Interconnection Between DPharp and the HART Communicator ...... 2-1 2.2 Communication Line Requirements .................................................... 2-1 2.3 Power Supply Voltage and Load Resistance ..................................... 2-1 3. OPERATION ................................................................................................ 3-1 3.1 Basic Operation of the 275 HART Communicator ............................. 3-1 3.1.1 Keys and Functions...................................................................... 3-1 3.1.2 Display .......................................................................................... 3-2 3.1.3 Calling Up Menu Addresses ........................................................ 3-2 3.1.4 Entering, Setting, and Sending Data ........................................... 3-3 3.2 Parameter Usage and Selection ......................................................... 3-4 3.3 Menu Tree ........................................................................................... 3-5 3.4 Basic Setup ......................................................................................... 3-6 3.4.1 Tag and Device Information ......................................................... 3-6 3.4.2 Unit ............................................................................................... 3-6 3.4.3 Range Change ............................................................................. 3-7 (1) Keypad input ................................................................................ 3-7 (2) Apply values ................................................................................. 3-8 3.4.4 Output Mode................................................................................. 3-9 3.4.5 Damping Time Constant Setup .................................................... 3-9 3.4.6 Output Signal Low Cut Mode Setup .......................................... 3-10 3.4.7 Impulse Line Connection Orientation Setup .............................. 3-10 3.5 Detailed Setup................................................................................... 3-11 3.5.1 Bi-directional Flow Measurement ............................................... 3-11 3.5.2 Integral Indicator Display Mode ................................................. 3-11 3.5.3 Integral Indicator Scale Setup .................................................... 3-12 3.5.4 Unit for Displayed Temperature ................................................. 3-14 3.5.5 Unit for Displayed Static Pressure ............................................. 3-14 3.5.6 Test Output................................................................................. 3-15 3.5.7 Sensor Trim ................................................................................ 3-16 (1) Zero Trim .................................................................................... 3-16 (2) Full Sensor Trim ......................................................................... 3-17 a. Auto Sensor Trim .................................................................... 3-17 b. Manual Sensor Trim ............................................................... 3-17 (3) Sensor Trim for Static Pressure................................................. 3-18 (4) Reset Trim Adjustment to Factory Setting ................................. 3-18 3.5.8 Trim Analog Output .................................................................... 3-18 3.5.9 Burst Mode ................................................................................. 3-20 3.5.10 Multidrop Mode........................................................................... 3-21 3.5.11 External Switch Mode ................................................................ 3-22 ii IM 01C25T01-01E CONTENTS 3.5.12 CPU Failure Burnout Direction and Hardware Write Protect .... 3-22 3.5.13 Software Write Protect ............................................................... 3-23 (1) Setting Password ....................................................................... 3-23 (2) Entering Password to Enable the Parameter Changes ............. 3-23 (3) Releasing Password................................................................... 3-23 (4) Software Seal ............................................................................. 3-24 3.5.14 Signal Characterizer ................................................................... 3-24 3.5.15 Process Alarm ............................................................................ 3-25 3.5.16 Status Output (option code AL) ................................................. 3-26 3.5.17 Capillary Fill Fluid Density Compensation ................................. 3-27 4. SELF-DIAGNOSTICS .................................................................................. 4-1 4.1 Self-Diagnostics .................................................................................. 4-1 4.1.1 Identify Problems by Using the Communicator ........................... 4-1 4.1.2 Checking with Integral Indicator ................................................... 4-1 4.2 Alarms and Countermeasures ............................................................ 4-2 5. PARAMETER SUMMARY ........................................................................... 5-1 APPENDIX 1. SAFETY INSTRUMENTED SYSTEMS INSTALLATION .......... A-1 REVISION RECORD
YOKOGAWA DpharpEJX vigilantplant EJX Series Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (131 pages)

  • Brand: YOKOGAWA
  • Model: DpharpEJX vigilantplant EJX Series
  • Format: PDF
  • Key Aspects: Hardware Verification Checklists, Device Specifications Overview, User Training Recommendations
  • Updated: 20.06.2026
  • Source File: 147756.pdf
  • Pages: 131
  • Description: Technical reference manual for the YOKOGAWA DpharpEJX vigilantplant EJX Series.

Document Preview & Text Transcription

Yokogawa Electric Corporation User’s Manual IM 01C25T02-01E EJX Series Fieldbus Communication Type IM 01C25T02-01E 4th Edition i CONTENTS IM 01C25T02-01E FD No. IM 01C25T02-01E 4th Edition: Apr. 2006(KP) All Rights Reserved, Copyright © 2004, Yokogawa Electric Corporation CONTENTS 1. INTRODUCTION............................................................................................ 1-1 Regarding This Manual ................................................................................. 1-1 1.1 Safe Use of This Product.................................................................... 1-2 1.2 Warranty .............................................................................................. 1-3 1.3 ATEX Documentation.......................................................................... 1-3 2. HANDLING CAUTIONS ................................................................................ 2-1 2.1 Installation of an Explosion-Protected Instrument .............................. 2-1 2.1.1 FM approval ................................................................................. 2-1 2.1.2 CSA Certification .......................................................................... 2-3 2.1.3 CENELEC ATEX Certification ...................................................... 2-4 3. ABOUT FIELDBUS ....................................................................................... 3-1 3.1 Outline ................................................................................................. 3-1 3.2 Internal Structure of EJX..................................................................... 3-1 3.2.1 System/network Management VFD ............................................. 3-1 3.2.2 Function Block VFD ..................................................................... 3-1 3.3 Logical Structure of Each Block.......................................................... 3-1 3.4 Wiring System Configuration .............................................................. 3-1 4. GETTING STARTED ..................................................................................... 4-1 4.1 Connection of Devices ........................................................................ 4-1 4.2 Host Setting......................................................................................... 4-2 4.3 Bus Power ON .................................................................................... 4-3 4.4 Integration of DD ................................................................................. 4-3 4.5 Reading the Parameters ..................................................................... 4-3 4.6 Continuous Record of Values ............................................................. 4-4 4.7 Generation of Alarm ............................................................................ 4-4 5. CONFIGURATION ......................................................................................... 5-1 5.1 Network Design ................................................................................... 5-1 5.2 Network Definition ............................................................................... 5-1 5.3 Definition of Combining Function Blocks ............................................ 5-2 5.4 Setting of Tags and Addresses .......................................................... 5-3 5.5 Communication Setting ....................................................................... 5-4 5.5.1 VCR Setting.................................................................................. 5-4 5.5.2 Function Block Execution Control ................................................ 5-5 5.6 Block Setting ....................................................................................... 5-5 5.6.1 Link Object ................................................................................... 5-5 5.6.2 Trend Object................................................................................. 5-6 5.6.3 View Object .................................................................................. 5-6 5.6.4 Function Block Parameters ........................................................ 5-10 ii CONTENTS IM 01C25T02-01E 6. EXPLANATION OF BASIC ITEMS............................................................... 6-1 6.1 Outline ................................................................................................. 6-1 6.2 Setting and Changing Parameters for the Whole Process ................ 6-1 6.3 SENSOR Transducer Block ................................................................ 6-1 6.3.1 Functional block ........................................................................... 6-1 6.3.2 Block Mode................................................................................... 6-1 6.3.3 Functions Relating to Pressure/Differential Pressure .................. 6-2 6.3.4 Functions Relating to Static Pressure.......................................... 6-3 6.3.5 Functions Relating to Capsule and Amplifier Temperature ......... 6-4 6.3.6 BLOCK_ERR ................................................................................ 6-4 6.3.7 XD_ERROR.................................................................................. 6-4 6.4 LCD Transducer Block ........................................................................ 6-5 6.4.1 Outline of the Functions ............................................................... 6-5 6.4.2 Block Mode................................................................................... 6-5 6.4.3 Display Contents of the integral indicator .................................... 6-5 6.4.4 Example Displays of the integral indicator................................... 6-6 6.4.5 Procedure to Set the Built-in Display ........................................... 6-7 6.4.6 Units That Can Be Displayed on the LCD by the Automatic Link Function ........................................................................................ 6-9 6.5 AI Function Block .............................................................................. 6-10 6.5.1 Function Blocks .......................................................................... 6-10 6.5.2 Block Mode................................................................................. 6-10 6.5.3 IO_OPTS .................................................................................... 6-10 6.5.4 STATUS_OPT ............................................................................ 6-10 6.5.5 OUT_D ....................................................................................... 6-11 6.5.6 Basic Parameters of the AI Block. ............................................. 6-11 7. IN-PROCESS OPERATION .......................................................................... 7-1 7.1 Mode Transition .................................................................................. 7-1 7.2 Generation of Alarm ............................................................................ 7-1 7.2.1 Indication of Alarm ....................................................................... 7-1 7.2.2 Alarms and Events ....................................................................... 7-1 7.3 Simulation Function............................................................................. 7-2 8. DEVICE INFORMATION ............................................................................... 8-1 8.1 DEVICE STATUS................................................................................ 8-1 8.2 Status of each parameter in failure mode .......................................... 8-4 9. PARAMETER LISTS ..................................................................................... 9-1 9.1 Resource Block ................................................................................... 9-1 9.2 SENSOR Transducer Block ................................................................ 9-3 9.3 LCD Transducer Block ........................................................................ 9-7 9.4 Al Function Block ................................................................................ 9-9 10. GENERAL SPECIFICATIONS .................................................................... 10-1 10.1 STANDARD SPECIFICATIONS ....................................................... 10-1 10.2 OPTIONAL SPECIFICATIONS ......................................................... 10-1 10.3 OPTIONAL SPECIFICATIONS (For Explosion Protected type)....... 10-2
YOKOGAWA DpharpEJX vigilantplant EJX Series Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (38 pages)

  • Brand: YOKOGAWA
  • Model: DpharpEJX vigilantplant EJX Series
  • Format: PDF
  • Key Aspects: Standard Operating Procedures, Best Practices for Everyday Use, Periodic Inspection Checklists
  • Updated: 31.03.2026
  • Source File: 147760.pdf
  • Pages: 38
  • Description: Maintenance and service manual for the YOKOGAWA DpharpEJX vigilantplant EJX Series.

Document Preview & Text Transcription

User’s Manual Yokogawa Electric Corporation EJX Series BRAIN Communication Type IM 01C25T03-01E IM 01C25T03-01E 2nd Edition i IM 01C25T03-01E CONTENTS FD No. IM 01C25T03-01E 2nd Edition: Oct. 2004 (YK) All Rights Reserved, Copyright © 2004, Yokogawa Electric Corporation CONTENTS 1. INTRODUCTION .......................................................................................... 1-1 Regarding This Manual ................................................................................. 1-1 1.1 Safe Use of This Product.................................................................... 1-2 1.2 Warranty .............................................................................................. 1-2 1.3 ATEX Documentation.......................................................................... 1-3 2. CONDITIONS OF COMMUNICATION LINE............................................... 2-1 2.1 Connecting the BT200 ........................................................................ 2-1 2.2 Communication Line Requirements .................................................... 2-1 2.3 Power Supply Voltage and Load Resistance ..................................... 2-1 3. OPERATION ................................................................................................ 3-1 3.1 BT200 Operating Procedures ............................................................. 3-1 3.1.1 Key Layout and Screen Display................................................... 3-1 3.1.2 Operating Key Functions.............................................................. 3-2 (1) Alphanumeric Keys and Shift Keys.............................................. 3-2 (2) Function Keys............................................................................... 3-2 3.1.3 Calling Up Menu Addresses Using the Operating Keys.............. 3-3 3.1.4 Printout (for BT200 printer option) ............................................... 3-3 3.2 Setting Parameters Using the BT200 ................................................. 3-4 3.2.1 Parameter Usage and Selection .................................................. 3-4 3.2.2 Menu Tree .................................................................................... 3-5 3.2.3 Setting Parameters....................................................................... 3-6 (1) Tag No. Setup .............................................................................. 3-6 (2) Calibration Range Setup .............................................................. 3-6 (3) Damping Time Constant Setup .................................................... 3-7 (4) Output Mode and Integral Indicator Display Mode Setup ........... 3-8 (5) Output Signal Low Cut Mode Setup ............................................ 3-8 (6) Integral Indicator Scale Setup ...................................................... 3-9 (7) Unit Setup for Displayed Temperature ...................................... 3-10 (8) Operation Mode Setup ............................................................... 3-10 (9) Impulse Line Connection Orientation Setup .............................. 3-11 (10) CPU Failure Burnout Direction and Hardware Write Protect.... 3-11 (11) Software Write Protect .............................................................. 3-11 (12) Output Status Setup when a Hardware Error Occurs .............. 3-12 (13) Bi-directional Flow Measurement Setup ................................... 3-12 (14) Range Change while Applying Actual Inputs ............................ 3-13 (15) Sensor Trim ............................................................................... 3-14 (16) Test Output Setup ..................................................................... 3-17 (17) Signal Characterizer .................................................................. 3-17 (18) Process Alarm ........................................................................... 3-18 (19) Status Output (option code AL)................................................. 3-18 (20) Capillary Fill Fluid Density Compensation ................................ 3-19 (21) Adjustment Information and User Memo Fields........................ 3-20 3.3 Displaying Data Using the BT200..................................................... 3-20 3.3.1 Displaying Measured Data ......................................................... 3-20 3.3.2 Display Transmitter Model and Specifications ........................... 3-20 ii IM 01C25T03-01E CONTENTS 4. SELF-DIAGNOSTICS .................................................................................. 4-1 4.1 Checking for Problems........................................................................ 4-1 4.1.1 Identifying Problems with BT200 ................................................. 4-1 4.1.2 Checking with Integral Indicator ................................................... 4-2 4.2 Alarms and Countermeasures ............................................................ 4-3 5. PARAMETER SUMMARY ........................................................................... 5-1 APPENDIX 1. SAFETY INSTRUMENTED SYSTEMS INSTALLATION .......... A-1 REVISION RECORD

DpharpEJX vigilantplant EJX Series: Related Instructions

Manuals from Other Manufacturers