YOKOGAWA FX1002 Manuals

3 pdf manual(s) YOKOGAWA FX1002 for free download (Document Types: Installation manual, Operation & user’s manual)

YOKOGAWA FX1002 Installation manual [PDF] (4 pages)

  • Identifier: id-797935
  • Brand: YOKOGAWA
  • Device: FX1002 Voice Recorder
  • Type: PDF
  • Key Aspects: Safety Recommendations and Warnings, Product Performance Metrics, Unpacking and Inspection Guidelines
  • UPD Date: 17.06.2026
  • Source File: 842253.pdf
  • Pages: 4
  • Description: Step-by-step user manual for the YOKOGAWA FX1002.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
IM 04L21B01-03EN page 1/4 Introduction Thank you for purchasing the FX1002, FX1004, FX1006, FX1008, FX1010, or FX1012 Paperless Recorder (hereafter referred to as “FX” or “FX1000”.). This manual describes the safty precautions and installation and wiring procedures of the FX1000. To ensure correct use, please read this manual and the manuals below thoroughly before beginning operation. For the product specifications, see the general specifications. Paper Manual Manual Title Manual No. * Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder Safety Precautions and Installation Guide Installing the FXA120 DAQSTANDARD FX1000 Mode Transition Diagram Setting Mode / Basic Setting Mode Maps (This manual) IM 04L21B01-03EN Electronic Manuals You can download these manuals from the following web page. You will need Adobe Reader 7 or later (latest version recommended) by Adobe Systems. http://www.yokogawa.com/ns/fx1000/im/ Manual Title Manual No. * Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder User’s Manual IM 04L21B01-01EN Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder First Step Guide IM 04L21B01-02EN Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder Safety Precautions and Installation Guide Installing the FXA120 DAQSTANDARD FX1000 Mode Transition Diagram Setting Mode / Basic Setting Mode Maps IM 04L21B01-03EN Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder Communication Interface (/C2, /C3, and /C7) IM 04L21B01-17EN FXA120 DAQSTANDARD for FX1000 Data Viewer IM 04L21B01-63EN FXA120 DAQSTANDARD for FX1000 Hardware Configurator IM 04L21B01-64EN Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder Usage Precautions IM 04L21B01-91EN General Specifications (GS) General Specifications Name General Specifications No. * Model FX1002/FX1004/FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder GS 04L21B0-02EN * The last two characters of the manual number and the general specifications number indicate the language in which the manuals or general specifications are written. The Authorised Representative for this product in the EEA is: Yokogawa Europe B.V. Euroweg 2, 3825 HD Amersfoort,The Netherlands Model and Suffix Codes A name plate is located on the top panel of the FX. Check that the model name and suffix code given on the name plate match those on your order. name plate M o d e l code Suffix code Optional code Description FX1002 2ch, Shortest measurement interval:125ms FX1004 4ch, Shortest measurement interval:125ms FX1006 6ch, Shortest measurement interval:1s FX1008 8ch, Shortest measurement interval:1s FX1010 10ch, Shortest measurement interval:1s FX1012 12ch, Shortest measurement interval:1s External storage medium slot -0 Without CF card slot/SD card slot and medium (Note) -4 With CF card slot and medium -7 With SD card slot and medium Language -2 English/German/French/Italian/ Spanish/ Portuguese/ Russian/ Korean deg F and DST W i t h s t a n d i n g voltage between measuring input terminals -H 1000 VAC(50/60 Hz), 1 min -L 400 VAC(50/60 Hz), 1 min Options /A1 Alarm output 2 points (C-contact) *1*10 /A2 Alarm output 4 points (C-contact) *1 /A3 Alarm output 6 points (C-contact) *1*3 /A4A Alarm output 12 points (A-contact) *1*3 /C2 RS-232 interface *2 /C3 RS-422A/485 interface *2 /C7 Ethernet interface /F1 FAIL/Status output *3 /M1 Mathematical functions (including Report functions) /N2 3 leg isolated RTD *4 /N3F Extended input type (without Pt1000) /P1 24 VDC/AC power supply /R1 Remote control 8 points *5 /TPS2 24VDC transmitter power supply (2 loops) *6*10 /TPS4 24VDC transmitter power suply (4 loops) *7 /USB1 USB interface (1 port) /PM1 Pulse input 3 points, Remote control 5 points (including Mathematical functions) *8 /CC1 Calibration correction function /LG1 Log scale /PWR1 Power monitor (1 A input, including Mathmatical functions) *9*10 /PWR5 Power monitor (5 A input, including Mathmatical functions) *10*11 /S# Customized product; details in IM FX1K-S#E *12 Note: To load data, the FX must be equipped with a communication interface (/C2, / C3 or /C7 option) or the USB interface (/USB1 option.) *1 Any combination of /A1, /A2, /A3, and /A4A cannot be specified together. *2 /C2 and /C3 cannot be specified together. *3 /A3 or /A4A cannot be specified together with /F1. *4 /N2 cannot be specified for FX1002 or FX1004. *5 If /R1 is specified, /A4A, /TPS2, /TPS4, /PM1, /PWR1, or /PWR5 cannot be specified. *6 If /TPS2 is specified, /TPS4, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified. *7 If /TPS4 is specified, /TPS2, /A1, /A2, /A3, /A4A, /F1, /R1, or /PM1 cannot be specified. *8 If /PM1 is specified, /A4A, /M1, /R1, /TPS2, /TPS4, /PWR1, or /PWR5 cannot be specified. *9 If /PWR1 is specified, /A3, /A4A, /F1, /R1, /PM1, /M1, or /PWR5 cannot be specified. *10 /TPS2, /PWR1, and /A1 cannot be specified together. /TPS2, /PWR5, and /A1 cannot be specified together. *11 If /PWR5 is specified, /A3, /A4A, /F1, /R1, /PM1, /M1, or /PWR1 cannot be specified. *12 Contact your supplier in case your instrument has option /S# (where ‘#’ is a number), and you are not in the possession of IM FX1K-S#E. Standard Accessories The standard accessories below are supplied with the instrument. Check that all contents are present and undamaged. 1 2 5 4 6 No. Name Model Qty. Notes 1 Mounting brackets B8730BU 2 For panel mounting 2 Rubber packing for dust and water protection - 1 For single-unit mounting 4 Model FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 Paperless Recorder Safety Precautions and Installation Guide Installing the FXA120 DAQSTANDARD FX1000 Mode Transition Diagram Setting Mode / Basic Setting Mode Maps IM 04L21B01- 03EN 1 A3 size 5 CF card *1 772093 1 512 MB 6 SD card *2 773001 1 1 GB *1 On FXs that have a CF card slot (suffix code -4.) CF card capacity is subject to change. *2 On FXs that have a SD card slot (suffix code -7.) SD card capacity is subject to change. *3 For optional accessories (Sold Separately), see the IM 04L21B01-02EN. Softoware (FXA120 DAQSTANDARD for FX1000), Label Please download the software and the label data from the following web page. http://www.yokogawa.com/ns/fx1000/soft/ Item Description Software FXA120 DAQSTANDARD for FX1000 Consists of the Data Viewer and the Hardware Configurator. Label Labels to Attach to the FX1000 Operation Cover Download the label data (Excel file). Print the label that you want to use. Label size: 19 ± 0.3 mm tall and 90 ± 0.3 mm wide File name: IM04L21B01-81Z1.xls 1. Safety Precautions The following safety symbols are used on the product and in this manual. WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences. CAUTION Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates pre- cautions that should be taken to prevent such occurrences. Protective ground terminal Alternating current Direct current “Handle with care.” To avoid injury and damage to the instrument, the operator must refer to the explanation in the manual. Note Identifies important information required to operate the instrument. n Safety Precautions • This instrument conforms to IEC safety class I (provided with terminal for protec- tive grounding), Installation Category II, and EN61326-1 (EMC standard), Mea- surement Category II (CAT II)*. * Measurement category II (CAT II) applies to measuring circuits connected to low voltage installation, and electrical instruments supplied with power from fixed equipment such as electric switchboards. • This instrument is an EN61326-1 (EMC standard) class A instrument (for use in commercial, industrial, or business environments). The influence rate (judgment condition A) in the immunity test environment is within ±15 % of the range or ±10 mV. • The general safety precautions described here must be observed during all phases of operation. If the FX is used in a manner not described in this manual, the FX safety features may be impaired. Yokogawa Electric Corporation assumes no li- ability for the customer’s failure to comply with these requirements. • The FX is designed for indoor use. n About User’s Manual • Please pass user’s manuals to the end user. We also ask you to store manuals in a safe place. • Read user’s manuals thoroughly and have a clear understanding of the product before operation. • User’s manuals explain the functions of the product. It does not guarantee that the product will suit a particular purpose of the user. n Precautions Related to the Protection, Safety, and Alteration of the Product • For the protection and safe use of the product and the system in which this product is incorporated, be sure to follow the instructions and precautions on safety that are stated in this manual whenever you handle the product. Take special note that if you handle the product in a manner that violates these instructions, the protection function- ality of the product may be damaged or impaired. In such cases, YOKOGAWA does not guarantee the quality, performance, function, and safety of product. • When installing protection and/or safety circuits such as lightning protection devices and equipment for the product and control system or designing or installing separate protection and/or safety circuits for fool-proof design and fail-safe design of the pro- cesses and lines that use the product and the control system, the user should imple- ment these using additional devices and equipment. • If you are replacing parts or consumable items of the product, make sure to use parts specified by YOKOGAWA. • This product is not designed or manufactured to be used in critical applications that di- rectly affect or threaten human lives. Such applications include nuclear power equipment, devices using radioactivity, railway facilities, aviation equipment, air navigation facilities, aviation facilities, and medical equipment. If so used, it is the user’s responsibility to in- clude in the system additional equipment and devices that ensure personnel safety. • Do not modify this product. WARNING l Use the Correct Power Supply Ensure that the source voltage matches the voltage of the power supply before turning ON the power. l Connect the Protective Grounding Terminal Make sure to connect the protective grounding to prevent electric shock before turning ON the power. l Do Not Impair the Protective Grounding Never cut off the internal or external protective grounding wire or disconnect the wiring of the protective grounding terminal. Doing so invalidates the protective functions of the instrument and poses a potential shock hazard. l Do Not Operate with Defective Protective Grounding Do not operate the instrument if the protective grounding might be defective. Also, make sure to check them before operation. l Do Not Operate in an Explosive Atmosphere Do not operate the instrument in the presence of flammable liquids or vapors. Operation in such an environment constitutes a safety hazard. Prolonged use in a highly dense corrosive gas (H2S, SOx, etc.) will cause a malfunction. l Do Not Remove Covers The cover should be removed by YOKOGAWA’s qualified personnel only. Opening the cover is dangerous, because some areas inside the instrument have high voltages. l Ground the Instrument before Making External Connections Connect the protective grounding before connecting to the item under measurement or control unit. l Damage to the Protection Operating the instrument in a manner not described in this manual may damage the instrument’s protection. CAUTION This instrument is a Class A product. Operation of this instrument in a residential area may cause radio interference, in which case the user is required to take appropriate measures to correct the interference. n Exemption from Responsibility • YOKOGAWA makes no warranties regarding the product except those stated in the WARRANTY that is provided separately. • YOKOGAWA assumes no liability to any party for any loss or damage, direct or indirect, caused by the user or any unpredictable defect of the product. 2. Installation n Installation Location Install the FX indoors in an environment that meets the following conditions: • Instrumentation Panel The FX is designed to be installed in an instrumentation panel. • Well-Ventilated Location To prevent overheating, install the FX in a well-ventilated location. For the panel cut dimensions when arranging multiple FXs, see “External Dimensions and Panel Cutout Dimensions.” When other instruments are installed next to the FX, follow the panel cut dimensions to provide adequate space around the FX. • Minimal Mechanical Vibrations Install the FX in a location that has minimal mechanical vibrations. Installing the FX in a location that is subject to large levels of mechanical vibration will not only put added stress on its components, it may also impede ordinary measurement. • Level Location Install the FX in a level location so that it is not slanted to the left or the right (how- ever, the FX can be inclined up to 30 degrees backward for panel mounting). Note Condensation may form when moving the FX from an environment whose temperature or humidity is low to an environment whose temperature or humidity is high, or when there is a sudden change in temperature. Temperature or humidity changes may also result in thermocouple measurement errors. In these kinds of circumstances, let the FX adjust to the new environment for at least an hour before using it. Do not install the FX in the following places. • Outdoors • In Direct Sunlight or Near Heat Sources Install the FX in a place that is near room temperature (23°C) and that is not sub- ject to large temperature fluctuations. Placing the FX in direct sunlight or near heat sources can cause adverse effects on the internal circuitry. • Where an Excessive Amount of Soot, Steam, Moisture, Dust, or Corrosive Gases Are Present Soot, steam, moisture, dust, and corrosive gases will adversely affect the FX. Avoid installing the FX in such locations. • Near Strong Magnetic Field Sources Do not bring magnets or instruments that produce electromagnetic fields close to the FX. Operating the FX near strong magnetic fields can cause measurement errors. • Where the Display Is Difficult to See The FX uses an LCD screen, so it is difficult to view the display from an extreme angle. Install the FX so that the user can view the display directly from the front. n Installation Procedure Use a steel panel that is 2 mm to 26 mm thick. 1) Insert the FX through the front of the panel. 2) Mount the FX to the panel using the included mounting brackets as shown in the figure below. Installation Guide IM 04L21B01-03EN Model FX1002/FX1004/FX1006 /FX1008/FX1010/FX1012 FX1000 Paperless Recorder Safety Precautions and Installation Guide 6th Edition : Nov. 2017

YOKOGAWA FX1002 Operation & user’s manual [PDF] (4 pages)

  • Identifier: id-1390309
  • Brand: YOKOGAWA
  • Device: FX1002 Measuring Instruments
  • Type: PDF
  • Key Aspects: Performance Optimization Tips, Manufacturer Contact and Support Data, Troubleshooting Information
  • UPD Date: 23.07.2026
  • Source File: 1337445.pdf
  • Pages: 4
  • Description: Quick reference guide for the YOKOGAWA FX1002.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
User’s Manual All Rights Reserved, Copyright © 2015 Yokogawa Electric Corporation Model FX1002/FX1004/FX1006 FX1008/FX1010/FX1012 FX1000 Paperless Recorder Usage Precautions Safety Precautions • This instrument conforms to IEC safety class I (provided with terminal for protective grounding), Installation Category II, and EN61326-1 (EMC standard), Measurement Category II (CAT II)*. * Measurement category II (CAT II) applies to measuring circuits connected to low voltage installation, and electrical instruments supplied with power from fixed equipment such as electric switchboards. • This instrument is an EN61326-1 (EMC standard) class A instrument (for use in commercial, industrial, or business environments). The influence rate (judgment condition A) in the immunity test environment is within ±15 % of the range or ±10 mV. • The general safety precautions described here must be observed during all phases of operation. If the FX is used in a manner not described in this manual, the FX safety features may be impaired. Yokogawa Electric Corporation assumes no liability for the customer’s failure to comply with these requirements. • The FX is designed for indoor use. • About User’s Manuals • Please pass user’s manuals to the end user. We also ask you to store manuals in a safe place. • Read user’s manuals thoroughly and have a clear understanding of the product before operation. • User’s manuals explain the functions of the product. It does not guarantee that the product will suit a particular purpose of the user. • Precautions Related to the Protection, Safety, and Alteration of the Product The following safety symbols are used on the product and in this manual. “Handle with care.” To avoid injury and damage to the instrument, the operator must refer to the explanation in the manual. Protective ground terminal Alternating current Direct current • For the protection and safe use of the product and the system in which this product is incorporated, be sure to follow the instructions and precautions on safety that are stated in this manual whenever you handle the product. Take special note that if you handle the product in a manner that violates these instructions, the protection functionality of the product may be damaged or impaired. In such cases, YOKOGAWA does not guarantee the quality, performance, function, and safety of product. • When installing protection and/or safety circuits such as lightning protection devices and equipment for the product and control system or designing or installing separate protection and/or safety circuits for fool-proof design and fail-safe design of the processes and lines that use the product and the control system, the user should implement these using additional devices and equipment. • If you are replacing parts or consumable items of the product, make sure to use parts specified by YOKOGAWA. • This product is not designed or manufactured to be used in critical applications that directly affect or threaten human lives. Such applications include nuclear power equipment, devices using radioactivity, railway facilities, aviation equipment, air navigation facilities, aviation facilities, and medical equipment. If so used, it is the user’s responsibility to include in the system additional equipment and devices that ensure personnel safety. • Do not modify this product. IM 04L21B01-91EN 3rd Edition: June, 2018

YOKOGAWA FX1002 Operation & user’s manual [PDF] (34 pages)

  • Identifier: id-989924
  • Brand: YOKOGAWA
  • Device: FX1002 Recording Equipment
  • Type: PDF
  • Key Aspects: Basic Configuration Guidelines, Advanced Configuration Methods, Step-by-Step Assembly Procedures
  • UPD Date: 04.05.2026
  • Source File: 1168565.pdf
  • Pages: 34
  • Description: Instruction reference guide for the YOKOGAWA FX1002.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
User’s Manual Yokogawa Electric Corporation Models FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 First Step Guide IM 04L21B01-02EN 2nd Edition

YOKOGAWA FX1002: Measuring Instruments, Recording Equipment, Voice Recorder Category Related Instructions

MC-3
Free The Tone MC-3
07.06.2026 10 pages

Step-by-step user manual for the Free The Tone MC-3 Recording Equipment. The document contains software configuration, connectivity setup, diagnostic information.

Hammerfall HDSP 9652
RME Audio Hammerfall HDSP 9652
21.07.2026 75 pages

User's Guide Hammerfall® DSP System HDSP 9652 PCI Busmaster Digital I/O System 2 + 24 Channels SPDIF / ADAT Interface 24 Bit / 96 kHz Digital Audio ADAT Sync In 2 x MIDI I/O TotalMix™ 24 Bit / 96 kHz 9 SyncAlign® ZLM® SyncCheck® Product usage manual for the RME Audio Hammerfall HDSP 9652 Recording Equipment. It explains troubleshooting and device features, operating instructions, support details.

A36D
La Marche A36D
06.06.2026 45 pages

La Marche Manufacturing Company www.lamarchemfg.com A36D Controlled Ferroresonant Rectifier / Power Supply Installation and Operation Manual 106 Bradrock Dr. Des Plaines 60018-1967 Tel: 847 299 1188 Fax: 847 299 3061 CPN 129389 Instructio Comprehensive setup guide for the La Marche A36D Battery Charger. This guide elaborates on device features and calibration steps, software configuration, installation support.

DP-008EX
Tascam DP-008EX
03.05.2026 92 pages

OWNER’S MANUAL D01175820A DP-008EX Digital Multitrack Recorder Maintenance instructions for the Tascam DP-008EX Recording Equipment. It details device setup and software configuration, basic operation, firmware updates, device overview.