YOKOGAWA Green Series Manuals

3 pdf manual(s) YOKOGAWA Green Series for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

1 IM05F01F12-01E User’s Manual IM 05F01F12-01E Jun. 2004 2nd Edition Please read through this user's manual to ensure correct usage of the manual setter and keep it handy for quick reference. 1. Notice 2. What is on the Front Panel? 3. Installing the Manual Setter 4. Panel Cutout Dimensions and External Dimensions 5. Wiring 6. Hardware Specifications 7. Key Operations 8. Troubleshooting ........................................................... 1 ................................. 1 ................................. 1 ..... 1 .......................................................... 2 ..................................... 2 ................................................ 3 ............................................... 3 Contents Revision Record IM 05F01F12-01E 1st Edition: Feb. ’01 2nd Edition: Jun. ’04 Models UD310/UD320/UD350 Manual Setters 1. Notice 2. What is on the Front Panel ? The following safety symbol is used both on the product and in this user's manual. This symbol stands for “Handle with Care.” When displayed on the product, the operator should refer to the corresponding explanation given in the user's manual in order to avoid injury or death of personnel and/or damage to the product. In the manual the symbol is accompanied by an expla- nation of the special care that is required to avoid shock or other dangers that may result in injury or loss of life. The following symbols are used in this manual only. NOTE Indicates that operating the hardware or software in a particular manner may lead to damage or result in system failure. IMPORTANT Draws attention to information that is essential for understanding the operation and/or features of the product. I Exemption from Responsibility Make sure that all of the precautions are strictly adhered to. Yokogawa Electric Corporation assumes no liability for any damage resulting from use of the instrument in contradiction to the precautions. Also, Yokogawa Electric Corporation assumes no liability to any party for any loss or damage, direct or indirect, caused by the use or any unpredictable defect of the instrument. a. b. d. UD320 UD350 UD310 e. c. a. b. d. c. e. c. e. a. b. d. UD310 UD320 UD350 a. PV display (red) Indicates PV (measured value) and character information such as parameter codes and error codes. PV goes out when the setup parameter ”PVD” is set to OFF. b. SP display (green) Indicates SP (target setpoint) and character information such as parameter setpoints. c. AL1, AL2 lamps (red) AL1 : Lit when alarm 1 is activated. AL2 : Lit when alarm 2 is activated. Name Function I Monitoring Parts CAUTION To prevent electric shock, the source of power to the manual setter must be turned off when mounting the manual setter on to a panel. NOTE To install the manual setter, select a location where: 1. No-one may accidentally touch the terminals; 6. There are no resulting magnetic disturbances; 2. Mechanical vibrations are minimal; 7. The terminal board (reference junction compen- 3. Corrosive gas is minimal; sation element, etc.) is protected from wind; 4. The temperature can be maintained at about 23°C with 8. There is no splashing of water; and minimal fluctuation; 9. There are no flammable materials. 5. There is no direct heat radiation; Never place the manual setter directly on flammable items. If the manual setter has to be installed close to flammable items or equipment, be sure to enclose the manual setter in shielding panels positioned at least 150mm away from each side. These panels should be made of either 1.43mm thick metal-plated steel plates or 1.6mm thick uncoated steel plates. G Mount the manual setter at an angle within 30° from horizontal with the screen facing upward. Do not mount it facing downward. 3. Installing the Manual Setter 150mm 150mm 150mm 150mm 30° (MAX) NOTE Splash-proof construction is not available when the side-by-side close mounting method shown in the above figure, is chosen for any of the manual setters. I Checking Package Contents Before using the product, check that its model & suffix codes are as you ordered. Check the package contents against the list below. • Manual Setter • Mounting bracket • User's manual (this manual) 1 1 for UD310 2 for UD320, UD350 1 ..................................... ................................ .................... Model Model and Suffix Codes Suffix code Description UD310 UD320 UD350 UD310 Manual Setter 4 to 20 mADC output (4848100 mm) UD320 Manual Setter 4 to 20 mADC output (4896100 mm) UD350 Manual Setter 4 to 20 mADC output (9696100 mm) –0 Always 0 0 Always 0 Power Supply 24V DC / 24V AC Option /V24 * 2 Alarm outputs and PV retransmission output in 4 to 20 mA built in as standard. Fixed code Fixed code 4. Panel Cutout Dimensions and External Dimensions max. 91.8 96 1-1051-6041-5031-4021-3011-20 min. 117 min. 145 92 + 0.8 0 92 + 0.8 0 25 53 +0.8 0 92 2. Side-by-side Close Mounting 1. General Mounting 96 11 100 max. 91.8 max. 112 Panel thickness 1 to 10 Unit: mm UD350 N is the number of manual setters. If N>5, then measure the actual length. [(N –1)×96+92] +0.8 0 1-1021-301-20 min. 70 48 min. 145 92+0.8 0 45+0.6 0 max. 44.6 max. 91.8 max. 112 100 96 Panel thickness 1 to 10 11 25 53 +0.8 0 92 2. Side-by-side Close Mounting 1. General Mounting Unit: mm UD320 N is the number of manual setters. If N>5, then measure the actual length. [(N –1)×48+45] +0.6 0 max. 61 Panel thickness max. 47.8 max. 44.8 max. 44.8 100 12 48 48 1 to 10 Unit: mm UD310 1. General Mounting min. 70 min. 70 45+0.6 0 45+0.6 0 25 25 [(N –1)×48+45] +0.6 0 +0.6 0 45 2. Side-by-side Close Mounting N is the number of manual setters. If N>5, then measure the actual length. UD310 UD320 UD350 I Mounting the Manual Setter UD320, UD350 UD310 Insert a screwdriver into the brackets to tighten the screws. Large bracket (top) Terminal board Panel Small bracket (bottom) Direction for mounting Insert the manual setter into the opening with the terminal board facing the front. Set and tighten the top and bottom brackets on the manual setter to fix it on the panel. 1. Affix the bracket over the back end of the manual setter. 2. Push the bracket to the panel, and then secure the bracket into position. Panel Bracket UD310 [ How to remove the bracket ] To remove the bracket, push down the center of the upper and lower parts of the manual setter softly. The bracket is released from the latch. d. Data change key • Changes SP(target setpoint) and the parameter values. Pressing this key increases the data value. SP (target setpoint) will be output in 3 seconds after the change. Holding down the key will gradually increase the speed of changes. Data change key • Changes SP(target setpoint) and the parameter setpoints. Pressing this key decreases the data value. SP (target setpoint) will be output in 3 seconds after the change. Holding down the key will gradually decrease the speed of changes. e. SET key (parameter data registering key) • Registers the parameter setpoint changed using the data change keys. • Switches between parameter setting displays sequentially. • Pressing the key for 3 seconds or longer in the operating display retrieves the operating parameter setting display. • Pressing the key for 3 seconds or longer in operating or setup parameter setting display transfers back to operating display. Name Function I Operating Parts (See 7. Key operations) 2 IM05F01F12-01E G Cable Specifications and Recommended Products G Recommended Terminals Use M3.5 screw-compatible crimp-on terminals with an insulating sleeve, as shown below. Power supply and relay contact output 600V vinyl insulated wire/cable, JIS C3307, 0.9 to 2.0mm2 Shielded wire (3-wire), UL2482 (Hitachi cable) Thermocouple input Shielded compensating lead wire, JIS C1610 RTD input Other signals Shielded wire 7mm or less 7mm or less ø 3.7mm ø 3.7mm CAUTION 1) Before you start wiring, turn off the power source and use a tester to check that the instrument and cables are not receiving any power in order to prevent electric shock. 2) For safety, be sure to install a circuit breaker switch (of 5A and 100V AC or 220V AC, and that conforms to IEC60947) near the instrument so as to be operated easily, and clearly indicate that the device is used to de- energize the instrument. 3) Wiring should be carried out by personnel with appropriate electrical knowledge and experience. NOTE 1) Use a single-phase power source. If the source has a lot of noise, use an isolation transformer for the primary side and a line filter (we recommend TDK’s ZAC2205-00U product) for the secondary side. When this noise-prevention measure is taken, keep the primary and secondary power cables well apart. Since the manual setter has no fuse, be sure to install a circuit breaker switch (of 5A and 100V AC or 220V AC, and that conforms to IEC standards) and clearly indicate that the device is used to de-energize the manual setter. 2) For thermocouple input, use shielded compensating lead wires. For RTD input, use shielded wires which have low resistance and no resistance difference between the 3 wires. See the table given later for the specifications of the cables and terminals and the recommended products. 3) The alarm output relay cannot be replaced even though it has a limited service life (100,000 relay contacts for the resistance load). Thus, an auxiliary relay should be used so that the load can be turned on and off. 4) When using an inductive load (L) such as an auxiliary relay and solenoid valve, be sure to insert a CR filter (for AC) or diode (for DC) in parallel as a spark-rejecting surge suppressor to prevent malfunctions or damage to the relay. 5) When there is the possibility of being struck by external lightening surge, use the arrester to protect the instrument. 5. Wiring 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ALM2 ALM1 COM Alarm Outputs 11 12 13 Manual Setting (SP) Output I Model UD310-00 Terminal Arrangement Power Supply 9 L N 10 100-240V AC 9 10 AC/DC 24V + – CAUTION To prevent damage to the manual setter, never provide 100-240V AC power supply for power supply AC/DC 24V model (when /V24 is specified). NOTE The and stand for the polarity for DC 24V power supply. + – NOTE Do not use unassigned terminals as relay terminals. NOTE Do not use unassigned terminals as relay terminals. TC Input RTD Input 7 8 6 7 8 + – B b A Universal input-selectable input type DC mV or V Input 7 8 + – Measured Value (PV) Input I Models UD320-00/UD350-00 Terminal Arrangement PV Retransmission Output + – 1 2 4 to 20 mA DC 4 to 20 mA Output 14 15 + – when /V24 option is specifed. 11 29 30 12 13 14 15 16 17 18 19 20 26 27 28 PV Retransmission Output + – 29 30 ALM2 ALM1 COM Alarm Outputs 16 17 18 Manual Setting (SP) Output 4 to 20 mA Output 14 15 + – TC Input RTD Input 12 13 11 12 13 + – B b A Universal input-selectable input type DC mV or V Input 12 13 + – Measured Value (PV) Input CAUTION To prevent damage to the manual setter, never provide 100-240V AC power supply for power supply AC/DC 24V model (when /V24 is specified). NOTE The and stand for the polarity for DC 24V power supply. + – Power Supply 19 L N 20 100-240V AC 19 20 AC/DC 24V + – when /V24 option is specifed. Note:The terminal arrangements of the UD320 and UD350 are the same. 7 8 Note: Connecting a 250 Ω resistor to the terminals is optional. Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs) * When receiving 4-20 mA DC current signals, set the PV input type to 1-5 V DC (setpoint “22”). Receiving 4-20 mA DC Current Signals with the Manual Setter 250 Ω4-20mA - + 12 13 Note: Connecting a 250 Ω resistor to the terminals is optional. Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs) * When receiving 4-20 mA DC current signals, set the PV input type to 1-5 V DC (setpoint “22”). Receiving 4-20 mA DC Current Signals with the Manual Setter 250 Ω4-20mA - + 4 to 20 mA DC 6. Hardware Specifications • Input: 1 point • Input type: Universal; can be selected by software • Input accuracy (at 23 ±2°C ambient temperature) • Thermocouple: ±2°C ±1digit However, • ±4°C for thermocouple input –200 to –100°C • ±3°C for thermocouple input –100 to 0°C • ±5°C for types R and S (±9°C for 0 to 500°C) • ±9°C for type B (accuracy is not guaranteed for 0 to 400°C) • RTD: ±1°C ±1digit •Voltage(mV, V) : ±0.3% ±1digit • Sampling period for measured value input: 500ms • Burn-out detection: Functions for thermocouple or RTD input (burn-out upscale only; cannot be switched off) • Input resistance: 1MΩ or greater for thermocouple or DC mV input. Approx. 1MΩ for DC V input • Maximum allowable signal source resistance : 250Ω for thermocouple or DC mV input 2kΩ for DC V input • Maximum allowable wiring resistance for RTD input: 10Ω/wire (The resistance values of three wires must be the same.) • Allowable input voltage: ±10V DC for thermocouple or DC mV input ±20V DC for DC V input • Noise rejection ratio: Normal mode noise: Min. 40dB (50/60Hz) Common mode noise: Min. 120dB (Min. 90dB for DC V input) • Error of reference junction compensation:±1.5°C (at 15-35°C) ±2.0°C (at 0-50°C) The reference junction compensation cannot be switched off. • Applicable standards: Thermocouple and resistance temperature detector(RTD) JIS/IEC/DIN (ITS90) SP (target setpoint) will be output in 3 seconds after the change. • Output: 1 point • Output type: Current output Output signal: 4 to 20mA current output Maximum load resistance: 600Ω Output accuracy: ±0.3% of span (at 23±2°C ambient temperature) Measured Value (PV) Input Alarm Functions Manual Setting (SP) Output • Output signal: Measured value in 4-20mA DC, can be scaled. • Maximum load resistance: 600Ω • Output accuracy: ±0.3% of span (at 23±2°C ambient temperature) Retransmission Output • Safety: Compliant with IEC/EN61010-1: 2001, approved by CSA1010, approved by UL508. Installation category : CAT. II (IEC/EN61010, CSA1010) Pollution degree : 2 (IEC/EN61010, CSA1010) Measurement category : I (CAT. I : IEC/EN61010) Rated measurement input voltage : 10V DC max.(across terminals), 300V AC max.(across ground) Rated transient overvoltage : 1500V (Note) Note : It is a value on the safety standard which is assumed by IEC/EN61010-1 in measurement category I, and is not the value which guarantees an apparatus performance. Caution: This equipment has Measurement category I, therefore do not use the equipment for measurements within measurement categories II, III and IV. •EMC standards: Complies with EN61326. The instrument continues to operate at a measuring accuracy of within ±20% of the range during tests. Safety and EMC Standards INormal Operating Conditions • Warm-up time: At least 30 minutes • Ambient temperature:0-50°C (0-40°C when mounted side-by-side) • Rate of change of temperature: 10°C/h or less • Ambient humidity: 20-90% RH (no condensation allowed) • Magnetic field: 400A/m or less • Continuous vibrations of 5 to 14Hz: Amplitude of 1.2mm or less • Continuous vibrations of 14 to 150Hz: 4.9m/s2 (0.5G) or less • Short-period vibrations: 14.7m/s2 (1.5G) for 15 seconds or less • Shock: 98m/s2 (10G) for 11 milliseconds or less • Mounting angle: Upward incline of up to 30 degrees; downward incline is not allowed. • Altitude: 2000m or less above sea level IMaximum Effects from Operating Conditions (1) Temperature effects • Thermocouple, DC mV and DC V input: ±2µV/°C or ±0.02% of F.S./°C, whichever is larger • Resistance temperature detector: ±0.05°C/°C • Analog output: ±0.05% of F.S./°C (2) Effect from fluctuation of power supply voltage (within rated voltage range) • Analog input: ±0.2µV/V or ±0.002% of F.S./V, whichever is larger • Analog output: ±0.05% of F.S. /V ITransportation and Storage Conditions • Temperature: –25 to 70°C • Humidity: 5 to 95% RH (no condensation allowed) • Shock: Package drop height 90cm (when packed in the dedicated package) Environmental Conditions IAlarm Functions • Alarm types: 22 types (waiting action can be set by software): PV high limit, PV low limit, Deviation high limit, Deviation low limit, De-energized on deviation high limit, De-energized on deviation low limit, Deviation high and low limits, Deviation within high and low limits, De- energized on PV high limit, De-energized on PV low limit, Fault diagnosis output, FAIL output • Alarm output: 2 relay contacts Relay contact capacity: 1A at 240V AC or 1A at 30V DC (with resistance load) (COM terminal is common) Note: The alarm output relays cannot be replaced by users. Construction, Mounting, and Wiring • Construction: Dust-proof and drip-proof front panel conforming to IP65 [Model UD310] and IP55 [Models UD320 and UD350]. For side-by-side close installation the controller loses its dust-proof and drip-proof protection. • Casing: ABS resin and polycarbonate • Case color: Black • Weight: UD310 - approx. 200g UD320 - approx. 300g UD350 - approx. 400g • Mounting: Flush panel mounting • Wiring: Screw terminals Power Supply and Isolation IPower Supply Note 1: The primary terminals are the power supply terminals and alarm output terminals. The secondary terminals are the analog input and output terminals. Note 2: AC/DC 24V terminals are secondary terminals. Maximum power consumption Voltage Frequency Between primary terminals and secondary terminals (See Notes 1 and 2.) Between primary terminals and secondary terminals (See Notes 1 and 2.) 50 or 60Hz Non-volatile memory 1500V AC for 1 minute 20MΩ or more at 500V DC Memory Withstanding voltage Insulation resistance Power supply Rated at 100-240VAC (±10%) AC/DC 24V, 20 to 29V of allowable range when /V24 is specified. 8VA max. (4W max.) 3W max. when /V24 is specified. I Isolation The bold lines below indicate reinforced isolation, and the broken line indicates functional isolation. Note: The measured value input terminals is isolated from the internal circuit. • Measured value input terminals • Internal circuit • Alarm output terminals (2 relay contacts) • Manual setting output terminals : 4-20 mA • Retransmission output terminals : 4-20 mA • Power supply terminals (100-240V AC) • Power supply terminals AC/DC 24V (When /V24 is specified) 1 2 3 4 Measurement category CAT.1 CAT.2 CAT.3 CAT.4 Remarks Appliances, portable equipments, etc. Distribution board, circuit breaker, etc. Overhead wire, cable systems, etc. Description For measurements performed on circuits not directly connected to MAINS. For measurements performed on circuits directly connected to the low voltage installation. For measurements performed in the building installation. For measurements performed at the source of the low-voltage installation. Internal Wiring Entrance Cable 4 3 T 2 IMPORTANT Two types of optional anti-electric-shock terminal covers (part numbers T9115YE and T9115YD) are available for the UD320 and UD350 manual setters, respectively. IMPORTANT Always fix a terminal cover bracket to the UD310 manual setter before wiring if an optional anti-electric-shock terminal cover (part number: L4000FB) is used. 3 IM05F01F12-01E CAUTION To prevent electric shock, the manual setter should be mounted on the panel so as not to accidentally touch the terminals when power is being applied. 7. Key Operations is displayed ? When measured input range code has been already set, the operating display shown below appears. Yes No Note: If no key is pressed for a period of two minutes or more while in the operating or setup parameter setting display, the manual setter automatically returns to operating display. • Displayed when AL1, AL2 = 1 to 20 LOC= When –1 When LOC=–1, transfers to the setup parameter setting display Press the key to move between items. When “In” appears, press the key to display the measured input range code you want to use, then press the key to register it. After this operation, the manual setter shows the operating display. Set -1 to enter the setup parameter setting display. But if LOC=1 or 2 is already set, the parameter value can not be changed by setting LOC=-1 only. To change the parameter value, set LOC=0 at first (for disabling keylock), then set LOC=-1 once again. NOTE Operating Display Set the parameters as follows not to display a measured input value. Measured input type (IN): DC voltage input (20 to 23) PV/SP display (PVD) : OFF TIP Power ON A Operating Parameter Setting Display Setup Parameter Setting Display A1 A2 FL BS LOC SPH SPL Displayed when DC voltage input range code (20 to 23) is set DP RH RL IN AL1 AL2 HY1 HY2 PVD NOTE A RTH RTL Measured input value(PV) Target setpoint(SP) UD310 No display Target setpoint(SP) UD310 Press the key for at least 3 seconds. Press the key to move between items. Press the key for at least 3 seconds. (To operating display) Note Press the key for at least 3 seconds. (To operating display) Note At first UD310 When parameter PVD=ON (factory-set default) When parameter PVD=OFF NOTE Changing certain setup parameters may automatically initialize the operating parameters. Therefore, after you change the setup parameters, always check the operating parameter setpoints to find out if appropriate values have been set for them. If the operating parameters have been initialized, set them to their appropriate values. G UD310/UD320/UD350 Measured Input Type and Ranges For example, to select thermocouple type J (°F), set the range code to 35. OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Thermocouple RTD DC voltage K J T E R S B N L U Platinel 2 Pt100 JPt100 0 to 100mV 0 to 5V 1 to 5V 0 to 10V –270 to 1370°C 0.0 to 600.0°C 0.0 to 400.0°C –199.9 to 200.0°C –199.9 to 999.9°C –199.9 to 400.0°C –199.9 to 999.9°C 0 to 1700°C 0 to 1700°C 0 to 1800°C –200 to 1300°C –199.9 to 900.0°C –199.9 to 400.0°C 0 to 1390°C –199.9 to 850.0°C 0.0 to 400.0°C –199.9 to 200.0°C –19.9 to 99.9°C –199.9 to 500.0°C –300 to 2500°F 32.0 to 999.9°F 32.0 to 750.0°F –300 to 400°F –300 to 2100°F –300 to 750°F –300 to 1800°F 32 to 3100°F 32 to 3100°F 32 to 3200°F –300 to 2400°F –300 to 1600°F –300 to 750°F 32 to 2500°F –199.9 to 999.9°F 32.0 to 750.0°F –300 to 400°F –199.9 to 999.9°F 0.0 to 100.0 0.000 to 5.000 1.000 to 5.000 0.00 to 10.00 User-scalable Input type Range (°C) Range (°F) Range code (°C) Range code (°F) UD310 Unspecifed NOTE At power-on, the manual setter displays the operating display, but if the measured input type setting remains OFF, “IN” appears. In this case, press the key to display the measured input range code you want to use, then press the key to register it. (Refer to the flowchart below.) IMPORTANT The manual setter is shipped with the parameters set at the factory-set defaults. Check the default values against the “Parameter Lists” in the following page, and change the parameter setpoints that need to be changed. This section explains how to set and register parameter setpoints. The procedure for changing Target Setpoint(SP) and Alarm 1 Setpoint(A1) can be found on "Changing Target Setpoint(SP)" and "Changing Alarm 1 Setpoint(A1)". You can set the other parameters in the same way. 8. Troubleshooting Is the manual setter defective? Completely inactive? Normal? Contact us for repair Problem solved Cancel the setting Key operation failure? Is the key locked? Normal? Correct it Check the terminal connection of the power supply Check key-lock setting Display failure? I/O signal failure? Turn the power off, then on Verify the I/O spec. of manual setter Verify the spec. of I/O destinations Check the power supply voltage Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No I When Power Failure Occurred during Operation G Momentary power failures shorter than 20ms(or shorter than 1ms when /V24 is specified) have no effect on the manual setter operation (i.e., normal operation continues). G For power failures of 20ms or longer(or 1ms or longer when /V24 is specified), however the status will be as follows. (The manual setter action at power recovery is the same as at power-on.) • Alarm action: Continues (but alarms with a waiting action enter the waiting state once) • Setting parameters: Maintained I Error Display during Operation (1) If the manual setter displays one of the following, carry out the appropriate remedy for the particular error. (2) The manual setter needs to be repaired if any of the indications in the table below appear. In these cases, do not try to repair the manual setter yourself. Order a new manual setter or contact us for repair. Display Display Unknown (at power-on) All extinguished (at power-on) “Err” (at power-on) Error content CPU failure Power source failure Calibration abnormal Display Flashing “Err” (at power-on) Flashing “Err” (during operation) Error content RAM or ROM failure A/D converter failure, RJC failure, or EEPROM failure Error content Remedy P.Er The parameter is abnormal Check the setpoints of all the parameters and set them at their proper values. B.o Input burnout Check the sensor wiring and correct it. Not display when the setup parameter PVD=OFF. OOO PV over-scale (PV exceeds its effective range.) Check the measured input type and scale settings and correct them. Not display when the setup parameter PVD=OFF. Set the setup parameter PVD=ON to display PV. UUU PV under-scale (PV falls below its effective range.) No PV display In the event of an abnormality, perform the following checks as outlined by the flowchart. (1) You can move between parameter setting displays using the key. (2) To change the parameter setpoint, ( i ) Change the display value with the or key (the period flashes). (ii) Press the key to register the setpoint. (3) In the operating display, pressing the key for at least 3 seconds retrieves the operating parameter setting display. (4) In the operating parameter setting display, pressing the key for at least 3 seconds transfers back to the oper- ating display. Registering the key-lock parameter LOC to “–1” retrieves the setup parameter setting display. (5) In the setup parameter setting display, pressing the key for at least 3 seconds transfers back to the operating display. The following instructions assume that the manual setter is already receiving power. SP (target setpoint) value will be output in 3 seconds after the change. Check alarm type before setting the alarm setpoint. Factory-set settings: Alarm 1 type : OFF Alarm 2 type : OFF Step 1: Confirm that the manual setter shows the operating display during normal operation (PV and SP are displayed on the indicators). Step 1: Confirm that the manual setter shows the operating display during normal operation (PV and SP are displayed on the indicators). Step 2: Press the or key to change the SP display value to the required setpoint. In this example, SP is changed to 200°C. Step 2: To enter the operating parameter setting display, press the key for at least 3 seconds. Press for at least 3 seconds. Step 3: Press the or key to change the current A1 setpoint to a required setpoint. In this example, A1 is changed to 200°C. The period flashes while the setpoint is being changed. Step 4: Press the key once to register the setpoint. The period goes out. A1 is now changed. Another press of the key calls up the Alarm 2 setpoint(A2) display. To return to the operating The period goes out. display, press the key for at least 3 seconds. I Changing Target Setpoint (SP) I Changing Alarm 1 Setpoint (A1) UD310 UD310 UD310 UD310 UD310 UD310 Measured input range Target setpoint range (Factory-shipped settings) Target setpoint range (after scaling) SPL SPL Minimum value of measured input range (scale) Maximum value of measured input range (scale) SPH 4mA 20mA SPH Manual setting output (4 to 20mA) 4 IM05F01F12-01E FL PV input filter OFF, 1 to 120 seconds OFF BS PV input bias –100 to 100% of measured input range (scale) span LOC Key lock (1) Operating Parameters : Parameters changed rather frequently during operation. A1 Alarm 1 setpoint Depends on the alarm 1 type. A2 Alarm 2 setpoint Depends on the alarm 2 type. IN Measured input type 1 to 23, 31 to 48 (See input range code list.) OFF: No input (If no input type is specified at the time of ordering, you must set the input type.) OFF, or the input range code specified with order DP Decimal point position of measured input 0: No decimal place (nnnn) 1: One decimal place (nnn.n) 2: Two decimal places (nn.nn) 3: Three decimal places (n.nnn) 1 RH Maximum value of measured input scale (RL + 1) to 9999 100.0 RL Minimum value of measured input scale –1999 to (RH –1) 0.0 SPH Maximum value of target setpoint range (Setpoint for manual setting output 20mA) SPH setting range: (SPL+1digit) to the maximum value of the measured input range (scale) ; Unit: °C/°F Maximum value of measured input range (scale) 0% of measured input range (scale) span SPL Minimum value of target setpoint range (Setpoint for manual setting output 4mA) SPL setting range: Minimum value of the measured input range (scale) to (SPH –1digit) ; Unit: °C/°F Minimum value of measured input range (scale) AL1 Alarm 1 type OFF or a value from 1 to 22 (see the table of alarm function list), and either OFF AL2 Alarm 2 type OFF HY1 Alarm 1 hysteresis 0.0 to 100.0% of measured input range (scale) span Unit: °C/°F 0.5% of measured input range (scale) span 0.5% of measured input range (scale) span HY2 Alarm 2 hysteresis PVD PV/SP display ON: Displays PV (measured input) and SP (target setpoint) OFF: Displays SP (target setpoint) ON (2) Setup Parameters : Parameters rarely changed in normal use after once having been set. 0: No key lock 1: Prevents parameter from being changed of except for SP in the operating display. 2: Prevents all parameter changing operations including SP in the operating display. –1: Set -1 to enter the setup parameter setting display. But if LOC=1 or 2 is already set, the parameter value can not be changed by setting LOC=-1 only. To change the parameter value, set LOC=0 at first (for disabling keylock), then set LOC=-1 once again. 0 RTH RTL Maximum value of retransmission output Minimum value of retransmission output (Displayed at voltage input) (Displayed at voltage input) (Displayed at voltage input) Temperature input : Within measured input range Voltage input : (RTL+1digit) to max. value of measured input scale(RH) Min. value of measured input scale(RL) to (RTH-1digit) However, RTL Minimum value of measured input range Maximum value of measured input range

Document Preview & Text Transcription

User’s Manual IM 05D01D13-41E Model UT351-xA Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User’s Manual IM 05D01D13-41E 4th Edition www.DataSheet4U.com www.DataSheet4U.com i IM 05D01D13-41E 4th Edition: May 31, 2006-00 Introduction Thank you for purchasing the UT351 digital indicating controllers. I How to Use the Manuals Purpose Description Setup Describes the tasks (installation, wiring, and others) required to make the controller ready for operations. Basic operation Describes examples of setting PV input types, control output types, and alarm types. Making settings described herein allows you to carry out basic control. Operating procedures and troubleshooting Describes key operation sequences. For operation control through external contact inputs, see “1.5 Terminal Wiring Diagrams.” Brief operation and setpoint recording Contains the parameter map used as a guideline for setting parameters and lists of parameters for recording User Settings. Title 1. Installation 2. Initial Settings 3. Operations 4.1 Troubleshooting 5. Parameters I Regarding This User’s Manual (1) This manual should be provided to the end user. Keep an extra copy or copies of the manual in a safe place. (2) Read this manual carefully to gain a thorough understanding of how to operate this product before starting operation. (3) This manual describes the functions of this product. Yokogawa Electric Corporation (hereinafter simply referred to as Yokogawa) does not guarantee the application of these functions for any particular purpose. (4) Under absolutely no circumstances may the contents of this manual, in part or in whole, be transcribed or copied without permission. (5) The contents of this manual are subject to change without prior notice. (6) Every effort has been made to ensure that the details of this manual are accurate. However, should any errors be found or important information be omitted, please contact your nearest Yokogawa representative or our sales office. Media No. IM 05D01D13-41E (CD) 4th Edition : May 2006 (YK) All Rights Reserved Copyright © 2004, Yokogawa Electric Corporation www.DataSheet4U.com

Document Preview & Text Transcription

User’s Manual Models UD310, UD320, UD350 Manual Setters IM 05F01F12-41E IM 05F01F12-41E 2004.6 3rd Edition Note: This user’s manual (IM 05F01F12-41E) is a re-edited, A4-size version of the IM 05F01F12-01E user’s manual that is supplied along with the product shipped. Therefore, both manuals have the same contents, except for some minor differences in the cross- referenced page numbers. Revision Record GManual No. : IM 05F01F12-41E(3rd Edition) GTitle : Models UD310,UD320,UD350 Manual Setters Edition First Date Feb.,2001 Revised Item Newly published Second Sep.,2003 Correct Third Jun.,2004 Change of the company name. IM 05F01F12-41E 1 I Checking Package Contents Before using the product, check that its model & suffix codes are as you ordered. Check the package contents against the list below. • Manual Setter • Mounting bracket • User's manual 1 1 for UD310 2 for UD320, UD350 1 ..................................... ................................ ..................................... Model Model and Suffix Codes Suffix code Description UD310 UD320 UD350 UD310 Manual Setter 4 to 20 mADC output (4848100 mm) UD320 Manual Setter 4 to 20 mADC output (4896100 mm) UD350 Manual Setter 4 to 20 mADC output (9696100 mm) –0 Always 0 0 Always 0 Power Supply 24V DC / 24V AC Option /V24 * 2 Alarm outputs and PV retransmission output in 4 to 20 mA built in as standard. Fixed code Fixed code Please read through this user’s manual to ensure correct usage of the manual setter and keep it handy for quick reference. CONTENTS 1. Notice ............................................................................................................................... 2 2. What is on the Front Panel? ......................................................................................... 3 3. Installing the Manual Setter ......................................................................................... 4 4. Panel Cutout Dimensions and External Dimensions.................................................. 5 5. Wiring .............................................................................................................................. 6 6. Hardware Specifications................................................................................................ 9 7. Key Operations ............................................................................................................. 10 8. Troubleshooting ............................................................................................................ 17