YOKOGAWA YTA110 Manuals

1 pdf manual(s) YOKOGAWA YTA110 for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

User’s Manual YTA Series Temperature Transmitters Manual Change No. 16-007-2 Jan. 1, 2017 Please use this manual change with the user’s manuals listed below. 1. Applicable Users’ Manual and Page IM 01C50B01-01E (16th) Item Page Applicable part and revised contents 1 1-1 Preface See 2.1 information to be added (1) 1 1-1 For Safe Use of Product See 2.2 information to be added (2) 2.7.1 b) 2-4 CSA Explosionproof Type Type 4X→TYPE 4X 2.7.2 (1) a) b) c) 2-6, 2-7 ATEX Intrinsically Safe “ia” ATEX Flameproof Type and Dust Ignition Proof Type ATEX Intrinsically Safe “ic” See 2.3 Change applicable standards and Type of Protection and Marking Code 2.7.2 (6) 2-9 Name Plate See 2.5 Change Name Plate 2.7.3 c) 2-11 FM Explosionproof Type NEMA-250→ANSI/NEMA 250, NEMA 4X→TYPE 4X IM 1C50B1→IM 01C50B01-01EN 2.7.5 c) 2-14 IECEx Flameproof Type and Dust Ignition Proof Type See 2.3 Change applicable standards and Type of Protection and Marking Code IM 01C50T02-01E (9th) Item Page Applicable part and revised contents 8.1.2 (1) A) 8-2 ATEX Flameproof Type and Dust Ignition Proof Type See 2.3 Change applicable standards and Type of Protection and Marking Code 8.1.2 (6) 8-7 Name Plate See 2.5 Change Name Plate 8.1.4 (1) A) 8-11 IECEx Flameproof Type and Dust Ignition Proof Type See 2.3 Change applicable standards and Type of Protection and Marking Code 9.2 9-2 Optional Specifications See 2.4 KS25 pending the sale to EEA market 2 2. Changed contents 2.1 Information to be added (1) This manual gives instructions on handling, wiring, installation, maintenance, and general specifications. To ensure correct use, please read this manual and following documents. Document No. Explanation IM 01C50B01-01E Hardware (This manual) IM 01C50T01-01E For HART protocol type IM 01C50T02-01E For FOUNDATION Fieldbus communication type IM 01C50T03-01E For BRAIN communication type GS 01C50B01-00EN YTA110 Temperature Transmitter GS 01C50B02-00EN YTA310/YTA320 Temperature Transmitter GS 01C50T01-00EN Model YTA Series HART Communication GS 01C50T02-00EN Model YTA Series Fieldbus Communication These documents can be downloaded from the website of Yokogawa. Website address: http://www.yokogawa.com/fld/ 2.2 Information to be added (2) � ■�For�Safe�Use�of�Product (e) Product Disposal The instrument should be disposed of in accordance with local and national legislation/regulations. (f) Authorized Representative in EEA In relation to the CE Marking, The authorized representative for this product in the EEA (European Economic Area) is: Yokogawa Europe B.V. Euroweg 2, 3825 HD Amersfoort,The Netherlands 2.3 Change applicable standards and Type of Protection and Marking Code Before Change After Change ATEX Intrinsically Safe “ia” Applicable Standard: EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 ATEX Intrinsically Safe “ia” Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 ATEX Flameproof Type and Dust Ignition Proof Type Applicable Standard: EN 60079-0:2012, EN 60079-1:2007, EN 60079-31:2009 Type of Protection and Marking Code: II 2 G Ex d IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C, T90°C Db ATEX Flameproof Type and Dust Ignition Proof Type Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079-31:2014 Type of Protection and Marking Code: II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C / T90°C Db ATEX Intrinsically Safe “ic” Applicable Standard: EN 60079-0:2012, EN 60079-11:2012 ATEX Intrinsically Safe “ic” Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 IECEx Flameproof Type and Dust Ignition Proof Type Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2007-04, IEC 60079-31:2008 Type of Protection and Marking Code: Ex d IIC T6/T5 Gb, Ex tb IIIC T70°C, T90°C Db IECEx Flameproof Type and Dust Ignition Proof Type Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2014-06, IEC 60079-31:2013 Type of Protection and Marking Code: Ex db IIC T6/T5 Gb, Ex tb IIIC T70°C / T90°C Db Manual Change No. 16-007-2 3 2.4 KS25 pending the sale to EEA market. Item Description Code ATEX ATEX Intrinsically Safe “ia” Approval Electrical Connection: 1/2 NPT female and M20 female KS25 (Note1) Note1: Because the examination of conformity to the updated standards is under the way, intrinsically safe type Ex ia (Option: KS25 for Fieldbus communication type) is pending the sale to EEA market. 2.5 Change Name Plate. 2.5.1 IM 01C50B01-01E MODEL NO. OUTPUT CAL RNG SUFFIX STYLE SUPPLY II 1 G No. KEMA 02ATEX1026 X Ex ia IIC T5 Ga Tamb -40 TO 50°C Ex ia IIC T4 Ga Tamb -40 TO 70°C ENCLOSURE: IP66/IP67 SUPPLY INPUT Ui=30V, Ii=165mA, Pi=900mW Ci=20nF, Li=730µH SENSOR OUTPUT Uo=9V, Io=40mA, Po=90mW Co=0.7µF, Lo=10mH POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL II 3 G Ex ic IIC T5...T4 Gc Tamb -30 TO 70°C (50°C for T5) ENCLOSURE: IP66/IP67 SUPPLY INPUT Ui=30V Ci=28nF, Li=730µH SENSOR OUTPUT Uo=9V, Io=40mA, Po=90mW Co=0.7µF, Lo=10mH II 2 GD No. KEMA 07ATEX0130 Ex d IIC T6/T5 Gb Ex tb IIIC T70°C, T90°C Db TEMP. CLASS T6/T5 Tamb(Gas) -40 to +75°C(T6) -40 to +80°C(T5) (Dust) -30 to +65°C(T70°C) -30 to +80°C(T90°C) ENCLOSURE: IP66/IP67 AFTER DE-ENERGIZING, DELAY 5 MINUTES BEFORE OPENING. WHEN THE AMBIENT TEMP.≥70°C, USE THE HEAT-RESISTING CABLES & CABLE GLANDS≥90°C. POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL II 1 G No. KEMA 02ATEX1026 X Ex ia IIC T5 Ga Tamb -40 TO 50°C Ex ia IIC T4 Ga Tamb -40 TO 70°C ENCLOSURE: IP66/IP67 SUPPLY INPUT Ui=30V, Ii=165mA, Pi=900mW Ci=20nF, Li=730µH SENSOR OUTPUT Uo=9V, Io=40mA, Po=90mW Co=0.7µF, Lo=10mH POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL II 3 G Ex ic IIC T5...T4 Gc Tamb -30 TO 70°C (50°C for T5) ENCLOSURE: IP66/IP67 SUPPLY INPUT Ui=30V Ci=28nF, Li=730µH SENSOR OUTPUT Uo=9V, Io=40mA, Po=90mW Co=0.7µF, Lo=10mH II 2 GD No. KEMA 07ATEX0130 Ex db IIC T6/T5 Gb Ex tb IIIC T70°C/T90°C Db TEMP. CLASS T6/T5 Tamb(Gas) -40 to +75°C(T6) -40 to +80°C(T5) (Dust) -30 to +65°C(T70°C) -30 to +80°C(T90°C) ENCLOSURE: IP66/IP67 AFTER DE-ENERGIZING, DELAY 5 MINUTES BEFORE OPENING. WHEN THE AMBIENT TEMP.≥70°C, USE THE HEAT-RESISTING CABLES & CABLE GLANDS≥90°C. POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’S MANUAL Before Change After Change MODEL NO. OUTPUT CAL RNG SUFFIX STYLE SUPPLY 2.5.2 IM 01C50T02-01E Name plate for flameproof type Name plate for flameproof type Before Change After Change TEMPERATURE TRANSMITTER YTA MODEL SUFFIX STYLE SUPPLY NO. OUTPUT CAL RNG TEMPERATURE TRANSMITTER YTA MODEL SUFFIX STYLE SUPPLY NO. OUTPUT CAL RNG No. KEMA 07ATEX0130 Ex d IIC T6/T5 Gb Ex tb IIIC T70°C, T90°C Db TEMP. CLASS T6/T5 Tamb (Gas) -40 to +75°C(T6) -40 to +80°C(T5) (Dust) -30 to +65°C(T70°C) -30 to +80°C(T90°C) ENCLOSURE: IP66/IP67 WARNING AFTER DE-ENERGIZING. DELAY 5 MINUTES BEFORE OPENING. WHEN THE AMBIENT TEMP.≥70°C, USE THE HEAT-RESISTING CABLES & CABLE GLANDS≥90°C. POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’ S MANUAL WARNING AFTER DE-ENERGIZING. DELAY 5 MINUTES BEFORE OPENING. WHEN THE AMBIENT TEMP.≥70°C, USE THE HEAT-RESISTING CABLES & CABLE GLANDS≥90°C. POTENTIAL ELECTROSTATIC CHARGING HAZARD -SEE USER’ S MANUAL No. KEMA 07ATEX0130 Ex db IIC T6/T5 Gb Ex tb IIIC T70°C/T90°C Db TEMP. CLASS T6/T5 Tamb (Gas) -40 to +75°C(T6) -40 to +80°C(T5) (Dust) -30 to +65°C(T70°C) -30 to +80°C(T90°C) ENCLOSURE: IP66/IP67 Manual Change No. 16-007-2