York E*BD-(T Manuals

1 pdf manual(s) York E*BD-(T for free download (Document Types: Technical manual)

York E*BD-(T Technical manual Main Page Preview

Technical manual [PDF] (32 pages)

  • Updated: 07.07.2026

Document Preview & Text Transcription

246819-BTG-H-0208 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT-SYSTEM HEAT PUMPS 13 SEER – R-22 MODELS: E*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) E*BD-(T,W)036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org LISTED ISO 9001 Certified Quality Management System TECHNICAL GUIDE TECHNICAL GUIDE DESCRIPTION The 13 SEER series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or hori- zontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. WARRANTY Single Phase Units: 5-year limited parts warranty. 5-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES • DURABLE CONSTRUCTION - The outdoor unit is con- structed of pre-painted steel that offers tough protection against corrosion and resists fading when exposed to sun- light. Drain holes are incorporated into the base pan to per- mit free drainage of moisture. • QUALITY COILS - The coil is constructed of enhanced copper tube and aluminum fins. • COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. • PROTECTED COMPRESSOR - The hermetic compressor is internally protected against high pressure and tempera- ture by the simultaneous operation of a high pressure relief valve and temperature sensors which stop the compressor if operating temperatures go too high. Both protectors reset automatically. A discharge line solid core filter drier further protects the compressor. • Complete System Control – These heat pumps utilize the unique microprocessor defrost control system to pro- vide optimal comfort and to monitor the overall system for reliable operation. The defrost control system continuously monitors the space environment to maintain optimum effi- ciency. It initiates defrost only when necessary to further reduce heating costs and improve reliability. In the event improper operating conditions occur, the control will auto- matically shut the system down to extend the life of the heat pump. Rapid cycling is prevented by use of an inter- nal anti-recycle timer. • LOW OPERATING SOUND LEVEL - The compressor is mounted on rubber isolators to reduce operating sounds. The slow moving condenser fan keeps air turbulence and sound to a low level. • EASY ACCESS - Removable panel affords accessibility to the electrical box. • FULLY CHARGED AND FACTORY WIRED - to simply installation and reduce labor costs. Only power supply and control wiring and refrigerant lines must be connected. All models are sweat connect with reusable service valves. • Factory tested - to verify system operation and control functioning before shipment. • U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment cer- tification program, which is based on ARI Standard 210/240. 246819-BTG-H-0208 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Physical and Electrical Data - 1 Phase MODEL EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Unit Supply Voltage 208-230V, 1φ, 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 9.9 15.0 16.9 19.8 25.0 32.7 37.8 Max. Overcurrent Device Amps 2 15 25 25 30 40 50 60 Min. Overcurrent Device Amps 3 15 20 20 20 30 35 40 Compressor Type 4 Recip Recip Recip Recip Recip ScrollD ScrollD Compressor Amps Rated Load 7.5 10.7 12.4 14.6 18.8 25.0 29.1 Locked Rotor 41 44 60 78 78 115 150 Crankcase Heater Yes Yes Yes Yes Yes No No Fan Motor Amps Rated Load 0.5 1.5 1.5 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 22 22 24 24 Fan Motor Rated HP 1/15 1/4 1/4 1/4 1/4 1/4 1/4 Nominal RPM 850 850 850 850 850 850 850 Nominal CFM 2,000 3,250 3,450 3,500 3,500 3,400 3,500 Coil Face Area Sq. Ft. 15.72 18.34 20.96 23.58 23.58 24.00 27.00 Rows Deep 1 1 1 1 1 2 2 Fin / Inches 22 22 22 22 22 18 18 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) 5 7 - 1 6 - 6 8 - 7 8 - 7 8 - 7 12 - 8 16 - 7 Charge Per Foot, Oz. 0.68 0.68 0.70 0.70 0.70 0.70 0.76 Operating Weight Lbs. 172 184 196 208 208 250 294 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. All scrolls listed with a superscript “D” are Danfoss scrolls. All scrolls listed with a superscript “C” are Copeland scrolls. 5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. A B C Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A1 1. Including Fan Guard. * Adapter fitting required for 1-1/8” line set. B C Liquid Vapor 018 27 37 27 3/8” 3/4” 024 31 37 27 030 35 37 27 7/8” 036 39 37 27 042 39 37 27 048 34 43 32 060 38 43 32 7/8”* 246819-BTG-H-0208 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz 7 - 1 6 - 9 8 - 9 8 - 7 8 - 7 12 - 8 16 - 7 Indoor Coil1,2 Additional Charge, Oz FC/MC/PC/UC18A2A 0 – – – – – – FC/MC/PC/UC18B2A 0 – – – – – – FC/MC/PC/UC24A2A – 0 – – – – – FC/MC/PC/UC24B2A – 0 – – – – – FC/MC/PC/UC30A2A – 0 – – – – – FC/MC/PC/UC30B2A – 0 – – – – – FC/MC/PC35B2A – – 0 9 – – – FC/MC/PC35C2C – – 0 9 – – – FC/MC/PC/UC42B2C – – 0 9 – – – FC/MC/PC/UC42C2C – – 0 9 – – – FC/MC/PC/UC48C2C – – – 9 14 – – FC/MC/PC/UC48D2C – – – 9 14 – – FC/PC/UC60C2C – – – – – 7 7 FC/MC/PC/UC60D2C – – – – – 7 7 MC61D2C – – – – – 7 7 HC18A2A 0 – – – – – – HC30A2A – 0 – – – – – HC36B2A – – 0 – – – – HC42C2C – – – 9 – – – HC60C2C – – – – – 7 7 HD24A2A – 0 – – – – – HD36B2A – – 0 9 – – – HD48C2C – – – – 14 – – HD60D2C – – – – – 7 7 AHP18B2A 0 – – – – – – AHP24B2A – 0 – – – – – AHP30B2A – – 0 – – – – AHP36C2A – – – 9 – – – AHP42C2C – – – 9 – – – AHP/SHP48D2C – – – – 14 7 – AHP/SHP60D2C – – – – – 7 7 AV24B2A 0 0 – – – – – AV36C2A – – 0 9 – – – AV/SV48D2C – – – – 14 7 – AV/SV60D2C – – – – – – 7 FC/MC/PC/UC18A3X 0 – – – – – – FC/MC/PC/UC18B3X 0 – – – – – – FC/MC/PC/UC24A3X – 0 – – – – – FC/MC/PC/UC24B3X – 0 – – – – – FC/MC/PC/UC30A3X – 0 – – – – – FC/MC/PC/UC30B3X – 0 – – – – – FC/MC/PC35B3X – – 0 9 – – – FC/MC/PC35X3X – – 0 9 – – – FC/MC/PC/UC42B3X – – 0 9 – – – FC/MC/PC/UC42X3X – – 0 9 – – – FC/MC/PC/UC48C3X – – – 9 14 – – FC/MC/PC/UC48D3X – – – 9 14 – – FC/PC/UC60C3X – – – – – 7 7 FC/MC/PC/UC60D3X – – – – – 7 7 MC61D3X – – – – – 7 7 HC18A3X 0 – – – – – – HC30A3X – 0 – – – – – HC36B3X – – 0 – – – – HC42C3X – – – 9 – – – HC60C3X – – – – – 7 7 For Notes See Page 4.