York SUNLINE 2000 48 Manuals

1 pdf manual(s) York SUNLINE 2000 48 for free download (Document Types: Technical manual)

York SUNLINE 2000 48 Technical manual [PDF] (24 pages)

  • Identifier: id-214167
  • Brand: York
  • Device: SUNLINE 2000 48 Heat Pump
  • Type: PDF
  • Key Aspects: Package Contents and Accessories List, Environmental Factors and Restrictions, Basic Configuration Guidelines
  • UPD Date: 30.06.2026
  • Source File: 148617.pdf
  • Pages: 24
  • Description: User reference manual for the York SUNLINE 2000 48.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
DESCRIPTION YORK Sunline 2000 Heat Pumps are convertible single package units with a common cabinet and common roof curb for the 3, 4 and 5 ton sizes. The units were designed for residential and light commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self--contained and assembled on rigid full perimeter base rails allowing for 3--way fork lift access and overhead rigging. Every unit is completely charged, wired, piped and tested at the factory to provide for a quick and easy field installation. The units are available with supplemental electric heaters as field--installed accessories. Both down and side discharge airflows are available without having to swap panels. The installer simply removes the duct covers for the desired configuration. Economizers may be used on either side or down discharge applications with no modifications required. All models include a 1--year limited warranty on the complete unit. Compressors and electric heater elements each carry an additional 4--year warranty. FEATURES CONTROLS -- These heat pumps utilize a unique time-- temperature defrost circuit which adjusts the time between defrost cycles based on the outdoor temperature to provide optimal comfort control and ensure reliable operation. The ambient--modified, time--temperature defrost control extends the time below 35°F and shortens the time above 35°F. The nominal defrost times are field adjustable to 50, 80 and 110 minutes. The defrost time is initiated and terminated by a liquid line control with a 10 minute override limit built into the defrost control. COMMON FOOTPRINT/COMMON CABINET -- The 3, 4 and 5 ton units all share the exact same cabinet -- and therefore the same roof curb. You now have the flexibility of setting one curb and, after the internal load has been determined, placing the proper tonnage unit on that curb. HIGH EFFICIENCY -- All units have a minimum SEER of 10, a COP of 3.0 (high) and 2.0 (low) and an HSPF as high as 7.3. These efficiencies exceed all legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN -- Both the side and bottom duct openings are covered when they leave the factory. If a side supply/side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply/return is desired, you simply remove the two bottom duct covers and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. FACTORY--INSTALLED OPTIONS -- Economizers can be installed at the factory. They are shipped installed and wired. The outdoorairhoodneedsonlytobefieldassembledandinstalled. Adjustable belt--drive blowers are available on most models from the factory for complete air flow flexibility. FIELD--INSTALLED ACCESSORIES -- Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in and electrical connections are made by modular plugs. Electric heaters mount easily and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. The motorized air damper includes a slid--in/plug--in damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of providing 0% through 100% of outdoor return air opening. The manual outdoor damper provides 0% through 35% or 0% through 100% of return air opening (field adjustable). Designed for duct mounted side or bottom supply/return applications. Includes rain hood assembly and filter. The 14" high roof curb is shipped knocked down. A roof curb deck is not required because the bottom of the unit is insulated. WIDE RANGE OF INDOOR AIRFLOWS -- All models operate over a wide range of design conditions with a 3--speed direct-- drive fan motor. Belt--drive blowers are also available on all models. FULL PERIMETER BASE RAILS -- The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. TECHNICAL GUIDE 036-21564-002-A-0404  SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS B3CH 036, 048 & 060 (208/230, 460V) B5CH 036 & 060 (575V), B6CH 048 3, 4 AND 5 NOMINAL TONS (10 SEER) SUNLINE 2000

York SUNLINE 2000 48: Heat Pump Category Related Instructions

AOYA18LALL
Fujitsu AOYA18LALL
06.07.2026 60 pages

Document n° 1350-2 ~ 15/01/2009 Fujitsu General (Euro) GmbH Werftstrasse 20 40549 Düsseldorf - Germany Subject to modifications without notice. Non contractual document. Heat pump air/water split single service Installation and operating manual intended for Operating handbook for the Fujitsu AOYA18LALL Heat Pump. It explains configuration options and firmware updates, safety precautions, software updates, installation steps.

PMFY Series
Mitsubishi Electric PMFY Series
03.05.2026 41 pages

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Indoor unit [Model names] [Service Ref.] No. OC307 REVISED EDITION-E INDOOR UNIT CONTENTS 1. TECHNICAL CHANGES.....................2 2. SAFETY PRECAUTION .....................3 3. PART NAMES Official installation manual for the Mitsubishi Electric PMFY Series Air Conditioner. This manual provides guidance on system checks, repair references, maintenance guidelines, technical troubleshooting.

HSS Series
Heat Controller HSS Series
23.05.2026 48 pages

Split Products HSS Series Split System, 11/2 to 5 Tons HTS Series Split System, Two Stage, 2-5 Tons Outdoor Split Geothermal Heat Pumps Installation, Operation & Maintenance Instructions Revision: 23 June, 2008 Model Nomenclature 3 Safety 4 Storage 5 Pre-Insta User support guide for the Heat Controller HSS Series Heat Pump. It provides instructions for user preferences, service contacts, service procedures, software updates.

E2FB090
York E2FB090
16.08.2026 12 pages

DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet the demands of the energy-and quality-conscious commercial market. Both the outdoor and indoor units are comple Full technical guide for the York E2FB090 Air Conditioner. The manual elaborates on features and wiring setup, usage examples, installation steps, performance optimization.