η ZESTAW STEROWANIA BEZPRZEWODOWEGO - OŚWIETLENIE RZB-01 Zamel Sp. z o.o., ul. Zielona 27, 43-200 Pszczyna tel.: +48 32 210 46 65, +48 32 449 15 00, fax: +48 32 210 80 04 e-mail: [email protected] www.zamel.com Nie wyrzucać tego urządzenia do śmietnika razem z innymi odpadami! Aby uniknąć szkodliwego wpływu na środowisko naturalne i zdrowie ludzi, zużyte urządzenie należy składować w miejscach do tego przeznaczonych. Elektrośmieci pochodzące z gospodarstwa domowego można oddać bezpłatnie i w dowolnej ilości do utworzonego w tym celu punktu zbierania, a także do sklepu przy okazji dokonywania zakupu nowego sprzętu. ZAMEL Sp. z o.o. niniejszym oświadcza, że typ urządzenia radiowego RNK-02, ROP-01 jest zgodny z dyrektywą 2014/53/UE. Pełny tekst deklaracji zgodności UE jest dostępny pod następującym adresem internetowym: www.zamel.com η ∆ û Β ý ζ Κ µ
Zamel RNK-02 Manual [PDF] (2 pages)
- Identifier: id-2278738
- Brand: Zamel
- Device: Zamel RNK-02 Transmitter
- Type: Manual , PDF
- Key Aspects: Warranty and Service Information, User Training Recommendations, Performance Optimization Tips
- UPD Date: 31.05.2026
- Source File: 2008887.pdf
- Pages: 2
- Description: Official user handbook for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
COOPERATION AND OPERATION RANGE * 1-channel transmitters do not cooperate with roller blind controllers. CAUTION: The given range concerns open area - an ideal condition with- out any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range accord- ing to: wood and plaster - from 5 to 20, bricks - from 10 to 40 %, reinforced concrete - from 40 to 80%, metal - from 90 to 100%, glass - from 10 to 20%. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m 2-CHANNEL BUTTON RADIO TRANSMITTER RNK-02 Input rated voltage: 3 V DC Battery type: CR2032 Battery working life: 3 ÷ 5 years (depending on use) Number of channels: 2 Transmission: radio 868,32 MHz Transmission way: unidirectional Coding: addressing transmission Range: up to 250 m in the open area Optical signalling of transmission/ battery discharge: LED red diode Ambient temperature range: -10 ÷ +55 °C Operating position: free Casing mounting: wall plugs, double-sided adhesive tape Casing protection degree: IP20 (EN 60529) Protection level: III Pollution degree: 2 Dimensions: 90 x 80 x 11,5 mm Weight: 0,038 kg Reference standard: PN-ETSI EN 300 220-1, PN-ETSI EN 300 220-2 TECHNICAL DATA DESCRIPTION RNK-02 button radio transmitter is an EXTA FREE wireless control, radio de- vice. It is used to realise control functions: switching on, switching off, brighten- ing/dimming, putting up/down roller blinds, time operation mode. The transmit- ter can be mounted on any surface including glass, wood, etc. thanks to its little size and weight, and external power supply which is not necessary.
Zamel RNK-02 Manual instruction [PDF] (2 pages)
- Identifier: id-2278797
- Brand: Zamel
- Device: Zamel RNK-02 Lighting Equipment
- Type: Manual instruction, PDF
- Key Aspects: Component Overview and Descriptions, FAQ Section for Common Queries, Package Contents and Accessories List
- UPD Date: 19.04.2026
- Source File: 2008828.pdf
- Pages: 2
- Description: Owner’s guide for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
RZB-02 WIRELESS CONTROL SET - LIGHTING WITH DIMMING FUNCTION MANUAL INSTRUCTION ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: [email protected] VER. 003_20.05.2011 APPEARANCE The device is designed for single-phase installation and must be installed in accord- ance with standards valid in a particular country. The device should be connected accord- ing to the details included in this operating manual. Installation, connection and control should be carried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. In case of casing dismantling an electric shock may occur, and the guarantee is lost then. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriv- er 3,5 mm should be used to instal the device. Im- proper transport, storage, and use of the device influence its wrong functioning. It is not advisable to instal the device in the following cases: if any device part is missing or the device is damaged or deformed. In case of improper functioning of the device contact the producer. CAutioN! FEAtuRES tECHNiCAL DAtA DESCRiPtioN ● complete set of wireless control (2–channel button radio transmitter RNK-02 and 1-channel radio flash dim- mer RDP-01), ● lighting operation control - switch on/ switch off, brightening and dimming, ● cooperation with light bulbs, fluores- cent lamps powered by electronic or toroidal transformer, ● memory of luminous density level, ● wide range of operation (up to 180 m), ● operation is optically signalled, ● low current consumption, possibility of constant work, ● possibility of widening operation range by means of RTN-01 retransmitter. RDP-01 dimmer cooperates with light bulbs, compact fluorescent lamps powe- red by electronic or toroidal power supply transformers. The device has different functions: a traditional lighting dimmer function, time control functions (staircase time delay switch), comfort functions (me- mory of adjusted luminous density level). RNK-02 RDP-01 Input (supply) terminals: - L, N Input rated voltage: 3 V DC (CR2032 battery) 230 V AC Battery life: 3 ÷ 5 years - Input voltage tolerance: - -15 ÷ +10 % Nominal frequency: - 50 / 60 Hz Nominal power consumption: - 0,5 W Number of operation modes: - 5 Number of channels: 2 1 Transmission: radio 868,32 MHz Coding way: unidirectional Coding: addressing transmission Maximum number of transmitters: - 32 Range: up to 250 m in the open area up to 230 m in the open area Time adjustment: - 1 sec ÷ 18 hours (every 1 sec.) Optic signalling of transmitter’s operation: LED red diode Receiver’s output clamps: - , N Maximum output load: - 250 W Number of terminal clamps: - 4 Section of connecting cables: - do 2,5 mm2 Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm Casing protection degree: IP20 (EN 60529) Protection level: III II Overvoltage category: - II Pollution degree: 2 Surge voltage: - 1 kV (EN 61000-4-5) Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm Weight: 0,038 kg 0,040 kg Reference standard: ETSI EN 300 220-1, ETSI EN 300 220-2 EN 60669, EN 60950, EN 61000 The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste. Optic signalling of receiver’s operation Programming push-button Receiver’s input (supply) terminals ( , N) Input (supply) terminals (L, N) Optic signalling of transmitter’s operation Push-button CoNNECtioN APPLiCAtioN RDP-01 MouNtiNG 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special measure equipment. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install RDP-01 device in installation cable box. 5. Switch on the power supply from the mains. RNK-02 FuNCtioNiNG, MouNtiNG By pressing the button, the transmitter sends a signal with 868,32 MHz frequency which controls EXTA FREE receivers. Device programming procedure (adding a transmitter to a receiv- er’s memory) is described in particular EXtA FREE manual instructions. The device range (up to 250 m depending on a receiver) can be in- creased by means of a retransmitter or few RTN- 01 retransmitters. The device can be mounted in any place by means of double-sided adhesive tape or two wall plugs (5x(3x30) mm. Mounting by means of wall plugs: 1. Remove the button - to do it press the button on one side, and on the other side put a screw- driver into a slot and lift up the button. 2. Find a place on the wall to mount the transmit- ter, make two holes corresponding mounting holes from the transmitter’s base. 3. Set wall plugs in the holes. 4. Fix the base by means of screwing screws into wall plugs. 5. Place the button again. BAttERY CHANGE Battery discharge status is signalled by sev- eral LED red diode flashes during transmis- sion time. 1. Remove the button (as in point 1 of mounting). 2. By means of a screwdriver lever up the printed- circuit board releasing the bottom latch (Fig. 2), and remove it from the base. 3. Remove the battery from the latch. 4. Mount a new battery. Watch battery polari- sation marked on the latch. Wrong battery mounting may cause device damage. 5. Put the removed printed-circuit board back in the base. 6. Put back the button. CAutioN: While changing the battery, it is suggested to press any of the buttons for about 5 seconds before putting it into a latch. Next press trans- mission button several times to check its op- eration. if the transmitter does not work prop- erly repeat the battery change procedure. Radio flush dimmer RDP-01 operates as a receiver of 2-channel button radio transmitter RNK-02 (switch on/switch off control, lighting source brightening/dimming). The above mentioned transmitters can also control operation of radio lighting switch RWL-01. CAPACitY 250W 250W 250W 250W WARRANtY CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS- TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear); 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 4. ZAMEL will review complaints in accordance with existing regulations.; 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract. Salesman stamp and signature, date of sale The ZAMEL company devices which are characterised with this sign can cooperate with each other.
Zamel RNK-02 Instruction manual [PDF] (2 pages)
- Identifier: id-2278739
- Brand: Zamel
- Device: Zamel RNK-02 Transmitter
- Type: Instruction manual, PDF
- Key Aspects: Risk Mitigation and Accident Prevention, User Training Recommendations, Environmental Factors and Restrictions
- UPD Date: 10.07.2026
- Source File: 2008886.pdf
- Pages: 2
- Description: Advanced user guide for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
2-CHANNEL BUTTON RADIO TRANSMITTER RNK-02 INSTRUCTION MANUAL ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: [email protected] VER. 004_20.05.2011 APPEARANCE TECHNICAL DATA RNK-02 Input rated voltage: 3 V DC Battery type: CR2032 Battery working life: 3 ÷ 5 years (depending on use) Number of channels: 2 Transmission: radio 868,32 MHz Transmission way: unidirectional Coding: addressing transmission Range: up to 250 m in the open area Optical signalling of transmission/battery discharge: LED red diode Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape Casing protection degree: IP20 (EN 60529) Protection level: III Pollution degree: 2 Dimensions: 90 x 80 x 11,5 mm Weight: 0,038 kg Reference standard: ETSI EN 300 220-1, ETSI EN 300 220-2 FEATURES: DESCRIPTION ●�2-channel�button�radio�transmitter, ●�remote�control�of�EXTA�FREE�receivers, ●�possibility� of� independent� control� of� two� receivers, ●�wide�range�of�operation�(up�to�250�m), battery powered, ●�easy�installation�and�mounting�possibility� in any place, ●�sending�information�and�battery�status�are� optically signalled, ●�possibility� of� simultaneous� switching� on� /� off� of� any� number� of� EXTA� FREE� receivers. RNK-02 button radio transmitter is an EXTA�FREE�wireless�control,�radio�device.� It is used to realise control functions: switch- ing on, switching off, brightening/dimming, putting up/down roller blinds, time opera- tion mode. The transmitter can be mounted on any surface including glass, wood, etc. thanks to its little size and weight, and ex- ternal power supply which is not necessary. The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste. Optical signalling of transmitter’s operation Button Base
Zamel RNK-02 Manual [PDF] (34 pages)
- Identifier: id-2278737
- Brand: Zamel
- Device: Zamel RNK-02 Transmitter
- Type: Manual , PDF
- Key Aspects: Safety Recommendations and Warnings, Storage and Care Recommendations, Glossary of Technical Terms
- UPD Date: 08.07.2026
- Source File: 2008888.pdf
- Pages: 34
- Description: Complete service manual for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
η RADIOWY NADAJNIK KLAWISZOWY 2-KANAŁOWY RNK-02 Zamel Sp. z o.o., ul. Zielona 27, 43-200 Pszczyna tel.: +48 32 210 46 65, +48 32 449 15 00, fax: +48 32 210 80 04 e-mail: [email protected] www.zamel.com Nie wyrzucać tego urządzenia do śmietnika razem z innymi odpadami! Aby uniknąć szkodliwego wpływu na środowisko naturalne i zdrowie ludzi, zużyte urządzenie należy składować w miejscach do tego przeznaczonych. Elektrośmieci pochodzące z gospodarstwa domowego można oddać bezpłatnie i w dowolnej ilości do utworzonego w tym celu punktu zbierania, a także do sklepu przy okazji dokonywania zakupu nowego sprzętu. ZAMEL Sp. z o.o. niniejszym oświadcza, że typ urządzenia radiowego RNK-02 jest zgodny z dyrektywą 2014/53/UE. Pełny tekst deklaracji zgodności UE jest dostępny pod następującym adresem internetowym: www.zamel.com η ∆ û Β ý ζ Κ µ
Zamel RNK-02 Manual [PDF] (2 pages)
- Identifier: id-2278816
- Brand: Zamel
- Device: Zamel RNK-02 Controller
- Type: Manual , PDF
- Key Aspects: Detailed Installation Instructions, Step-by-Step Assembly Procedures, Glossary of Technical Terms
- UPD Date: 04.08.2026
- Source File: 2008809.pdf
- Pages: 2
- Description: Setup and usage guide for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
COOPERATION AND OPERATING RANGE * 1-channel transmitters do not cooperate with roller blind controllers CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plas- ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmit- ters set close to a device system have also a negative influence on the range. Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m TIME PROGRAMMING Press PROG push-button of ROP-01 device for a longer time till LED red diode switches on (constant signal). Next release PROG push-button. Wait (for about 5 sec- onds) till LED red diode switches on (first signal pulsates, next the signal is constant). Press PROG push-button of ROP-01 device and then release it. LED red diode switches off and then switches on (signal pulsates). Every LED diode pulse equals 1 second. After the adjusted time is finished (the number of LED red diode flashes) press PROG push-button and then release it - TIME IS ADDED. Maximum time is 18 hours. RADIO TRANSMITTERS DELETION Press PROG push-button of ROP-01 device for a longer time. After 5 seconds LED red diode switches on (signal pulsates) and then it switches off. Release the push-button in ROP-01 - MEMORY IS DELETED. CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. WIRELESS CONTROL SET - LIGHTING RZB-01 TECHNICAL DATA RNK-02 ROP-01 Input (supply) terminals: - L, N Input rated voltage: 3 V (battery CR2032) 230 V AC Battery life: 3 ÷ 5 years - Input voltage tolerance: - -15 ÷ +10 % Nominal frequency: - 50 / 60 Hz Nominal power consumption: - 0,29 W Number of operation modes: - 5 Number of channels: 2 1 Transmission: radio 868,32 MHz Transmission way: unidirectional Coding: addressing transmission Maximum number of transmitters: - 32 Range: up to 250 m in the open air up to 230 m in the open air Time adjustment: - 1 с ÷ 18 hours (every second) Optical signalling: LED red diode Relay output clamps: - 12, 11, 14 Relay contacts parameters: - 1NO/NC 5A / 250V AC AC1 1250 VA Number of terminal clamps: - 5 Section of connecting cables: - up to 2,5 mm2 Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm Casing protection degree: IP20 (EN 60529) Protection level: III II Overvoltage category: - II Pollution degree: 2 Surge voltage: - 1 kV (EN 61000-4-5) Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm Weight: 0,038 kg 0,043 kg Reference standard: PN-ETSI EN 300 220-1 PN-ETSI EN 300 220-2 PN-EN 60669, PN-EN 60950 PN-EN 61000
Zamel RNK-02 Manual [PDF] (2 pages)
- Identifier: id-2278815
- Brand: Zamel
- Device: Zamel RNK-02 Controller
- Type: Manual , PDF
- Key Aspects: Manufacturer Contact and Support Data, Best Practices for Everyday Use, Package Contents and Accessories List
- UPD Date: 23.08.2026
- Source File: 2008810.pdf
- Pages: 2
- Description: General instruction manual for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
COOPERATION AND OPERATING RANGE * 1-channel transmitters do not cooperate with roller blind controllers CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plas- ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmit- ters set close to a device system have also a negative influence on the range. Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m none* none* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m none* none* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m REMOTE CONTROLS DELETION Press PROG push-button of RDP-01 device for a longer time. After 5 seconds LED red diode switches on (signal pulsates) and then it switches off. Release the push- button in RDP-01 - MEMORY IS DELETED. TIME PROGRAMMING Press PROG push-button of RDP-01 device for a longer time till LED red diode switches on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red diode switches on (first signal pulsates, next the signal is constant). Press PROG push- button of RDP-01 device and then release it. LED red diode switches off and then switches on (signal pulsates). Every LED diode pulse equals 1 second. After the adjusted time is finished (the number of LED red diode flashes) press PROG push-button and then release it - TIME IS ADDED. Maximum time is 18 hours. TIME mode (one push-button): Press PROG push-button of RDP-01 device for a longer time till LED red diode switches on (constant signal). Next release PROG push-button. Press and then re- lease transmitter’s push-button.LED red diode switches on (first signal pulsates, next the signal is constant). Press and release the same transmitter’s push-button. LED red diode switches on (signal pulsates) and then switches off - THE TRANSMITTER IS ADDED. CAUTION: Every transmitter can cooperate with RDP-01 in a different mode, de- pending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. WIRELESS CONTROL SET - LIGHTING WITH DIMMING FUNCTION RZB-02 TECHNICAL DATA RNK-02 RDP-01 Input (supply) terminals: - L, N Input rated voltage: 3 V DC (battery CR2032) 230 V AC Battery life: 3 ÷ 5 years - Input voltage tolerance: - -15 ÷ +10 % Nominal frequency: - 50 / 60 Hz Nominal power consumption: - 0,5 W Number of operation modes: - 5 Number of channels: 2 1 Transmission: radio 868,32 MHz Transmission way: unidirectional Coding: addressing transmission Maximum number of transmitters: - 32 Range: up to 250 m in the open air up to 230 m in the open air Time adjustment: - 1 s ÷ 18 hours (every second) Optical signalling: LED red diode Receiver’s output clamps: - , N Maximum output load: - 250 W Number of terminal clamps: - 4 Section of connecting cables: - up to 2,5 mm2 Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm Casing protection degree: IP20 (EN 60529) Protection level: III II Overvoltage category: - II Pollution degree: 2 Surge voltage: - 1 kV (EN 61000-4-5) Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm Weight: 0,038 kg 0,040 kg Reference standard: PN-ETSI EN 300 220-1, PN-ETSI EN 300 220-2 PN-EN 60669, PN-EN 60950, PN-EN 61000
Zamel RNK-02 Instruction manual [PDF] (2 pages)
- Identifier: id-1630987
- Brand: Zamel
- Device: Zamel RNK-02 Controller
- Type: Instruction manual, PDF
- Key Aspects: Advanced Configuration Methods, User Training Recommendations, Environmental Factors and Restrictions
- UPD Date: 01.07.2026
- Source File: 1687742.pdf
- Pages: 2
- Description: Device setup manual for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
RZB-03 WIRELESS CONTROL SET – ROLLER BLINDS CONTROL MANUAL INSTRUCTION ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: [email protected] VER. 003_20.05.2011 APPEARANCE The device is designed for single-phase installation and must be installed in accord- ance with standards valid in a particular country. The de- vice should be connected ac- cording to the details included in this operating manual. Installation, connection and control should be carried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. In case of casing dismantling an electric shock may occur, and the guarantee is lost then. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriv- er 3,5 mm should be used to instal the device. Im- proper transport, storage, and use of the device influence its wrong functioning. It is not advisable to instal the device in the following cases: if any device part is missing or the device is damaged or deformed. In case of improper functioning of the device contact the producer. Caution! FEATURES TECHNICAL DATA DESCRIPTION ● Complete set of wireless control (2–channel button radio transmitter RNK-02 and radio roller blinds controller SRP-02), ● used in wired and wireless control of roller blind, sunblind and gate drives, (electric motors of 230V AC), ● wired local control inputs, ● easily installed in Ø60 mm junction box, ● energy-saving device, possibility of con- stant work, ● two comfort modes - upper and bottom (memory of roller blind height level), ● possibility of cooperation with any roler blind switch (which is not equipped in backlight elements) SRP-02 controller is used to control roller blind drives with 230V AC motor with a limit switch. The device realises roller blinds local and central control functions and it has the possibility of comfort mode adjustment. Comfort modes are used to adjust roller blinds position (height level) and to memorise the height level. Central mode is used in case of a totally closed or opened roller blind or a group of roller blinds with different position level. RNK-02 SRP-02 Input (supply) terminals: - L, N Input rated voltage: 3 V DC (CR2032 battery) 230 V AC Battery life: 3 ÷ 5 years - Input voltage tolerance: - +10 ÷ -15 % Nominal frequency: - 50 / 60 Hz Nominal power consumption: - 0,4 W („stand-by” mode) / 0,7 W (roller blind movement) Transmission: radio 868,32 MHz Coding way: unidirectional Coding: addressing transmission Maximum number of remote controls: - 32 Range: up to 250 m in the open area Maximum movement time of roller blind: - 120 sec Maximum time of roller blind movement: - 1 ÷ 120 sec (every 0,1 sec) Optic signalling of transmitter’s operation: LED red diode Local control terminals: - LOCAL (up), (down) Motor power supply terminals: - (up), (down) Relay contact parameters: - 2NO 5A/250V AC AC3 1250 VA Number of terminal clamps: - 6 Section of connecting cables: - up to 2,5 mm2 Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm Casing protection degree: IP20 (EN 60529) Protection level: III II Overvoltage category: - II Pollution degree: 2 Surge voltage: - 1 kV (EN 61000-4-5) Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm Weight: 0,038 kg 0,039 kg Reference standard: ETSI EN 300 220-1 ETSI EN 300 220-2 EN 60669, EN 60950, EN 61000 The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste Optic signalling of receiver’s operation Programming push-button Local wired control terminals (upward movement , downward movement ) Roller blind motor terminals (upward movement , downward movement ) Input (supply) terminals (L, N) Optic signalling of transmitter’s operation Push-button CONNECTION APPLICATION LOCAL LOCAL SRP-02 MOUNTING 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special measure equipment. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install SRP-02 device in installation cable box. 5. Switch on the power supply from the mains. RNK-02 FUNCTIONING, MOUNTING By pressing the button, the transmitter sends a signal with 868,32 MHz frequency which controls EXTA FREE receivers. Device programming procedure (adding a transmitter to a receiv- er’s memory) is described in particular EXTA FREE manual instructions. The device range (up to 250 m depending on a receiver) can be in- creased by means of a retransmitter or few RTN- 01 retransmitters. The device can be mounted in any place by means of double-sided adhesive tape or two wall plugs (5x(3x30) mm. Mounting by means of wall plugs: 1. Remove the button - to do it press the button on one side, and on the other side put a screw- driver into a slot and lift up the button. 2. Find a place on the wall to mount the transmit- ter, make two holes corresponding mounting holes from the transmitter’s base. 3. Set wall plugs in the holes. 4. Fix the base by means of screwing screws into wall plugs. 5. Place the button again. BATTERY CHANGE Battery discharge status is signalled by sev- eral LED red diode flashes during transmis- sion time. 1. Remove the button (mounting - point 1). 2. By means of a screwdriver lever up the printed- circuit board releasing the bottom latch and re- move it from the base. 3. Remove the battery from the latch. 4. Mount a new battery. Watch battery polari- sation marked on the latch. Wrong battery mounting may cause device damage. 5. Put the removed printed-circuit board back in the base. 6. Put back the button. CAUTION: While changing the battery, it is suggested to press any of the buttons for about 5 seconds before putting it into a latch. Next press trans- mission button several times to check its op- eration. If the transmitter does not work prop- erly repeat the battery change procedure. WARRANTY CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS- TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear); 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 4. ZAMEL will review complaints in accordance with existing regulations.; 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract. Salesman stamp and signature, date of sale CAUTION: Local switches connection (LOCAL) is optional. Radio flush dimmer RNK-02 operating roller blind controller SRP-02 (roller blind opening / closing). The above mentioned transmitter can be added to any number of receivers. The ZAMEL company devices which are characterised with this sign can cooperate with each other.
Zamel RNK-02 Manual [PDF] (2 pages)
- Identifier: id-1630993
- Brand: Zamel
- Device: Zamel RNK-02 Control Unit
- Type: Manual , PDF
- Key Aspects: Troubleshooting Information, Best Practices for Everyday Use, Regulatory Compliance and Standards
- UPD Date: 02.04.2026
- Source File: 1687736.pdf
- Pages: 2
- Description: Setup and usage guide for the Zamel RNK-02.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
COOPERATION AND OPERATING RANGE * 1-channel transmitters do not cooperate with roller blind controllers CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and pla- ster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmit- ters set close to a device system have also a negative influence on the range. Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of SRP-02 device for a longer time. After 5 seconds LED red diode switches on (signal pulsates) and then it switches off. Release the push-button in SRP-02 - MEMORY IS DELETED. RADIO TRANSMITTERS DELETION COMFORT MODE TIME PROGRAMMING Open the roller blind completely. Press PROG push-button of SRP-02 device for a longer time until LED red diode switches on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red diode switches on (first signal pulsates, next the signal is constant). Wait again (for about 5 seconds) till LED red diode switches on (first signal pulsates, next the signal is constant). Press PROG push-button of SRP-02 device, next release PROG push-button - the roller blind moves automatically. If the roller blind is in a required comfort position - press PROG push-button and release it - the roller blind stops - ROLLER BLIND MOVEMENT TIME IS ADDED. WIRELESS CONTROL SET - ROLLER BLINDS CONTROL RZB-03 TECHNICAL DATA RNK-02 SRP-02 Input (supply) terminals: - L, N Input rated voltage: 3 V (battery CR2032) 230 V~ Battery life: 3 ÷ 5 years - Input voltage tolerance: - +10 ÷ -15 % Nominal frequency: - 50 / 60 Hz Nominal power consumption: - 0,4 W („stand-by” mode) 0,7 W (roller blind movement) Transmission: radio 868,32 MHz Transmission way: unidirectional Coding: addressing transmission Maximum number of transmitters: - 32 Range: up to 250 m in the open air Maximum time of roller blind movement: - 120 s Comfort mode time adjustment: - 1 ÷ 120 sec (every 0,1 sec) Optical signalling: LED red diode Local control terminals: - LOCAL (up), (down) Roller blind motor power supply terminals: - (up), (down) Relay contact parameters: - 2NO 5A / 250V AC3 1250 VA Number of terminal clamps: - 6 Section of connecting cables: - up to 2,5 mm2 Ambient temperature range: -10 ÷ +55 oC Operating position: free Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm Casing protection degree: IP20 (PN-EN 60529) Protection level: III II Overvoltage category: - II Pollution degree: 2 Surge voltage: - 1 kV (PN-EN 61000-4-5) Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm Weight: 0,038 kg 0,039 kg Reference standard: PN-ETSI EN 300 220-1 PN-ETSI EN 300 220-2 PN-EN 60669, PN-EN 60950, PN-EN 61000
Similar Manuals in the Controller, Control Unit, Lighting Equipment, Transmitter Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Allen-Bradley 1756-HYD02 |
Allen-Bradley Control Unit Installation instructions manual (File: PDF, 24-03-2026) |
24 | 1461 | 293 | 24-03-2026 | view all manuals | |
Volt HT-10R |
PDF Guide (@Y74BRO), Volt HT-10R Control Unit (16-06-2026) |
6 | 872 | 131 | 16-06-2026 | view all manuals | |
Agilent Technologies 1100 Series |
Security Sensors #9ZETAB |
334 | 951 | 200 | 15-08-2026 | view all manuals | |
Comeval UNIWAT VF791 Series |
Comeval Control Unit Installation, operating and maintenance manual (File: PDF, 27-08-2026) |
8 | 1229 | 197 | 27-08-2026 | view all manuals | |
Honeywell SK-Mon-10 |
SK-Mon-10 Installation and maintenance instructions - E9PR27 |
3 | 1476 | 310 | 07-08-2026 | view all manuals | |
Watson McDaniel UTS600 Series |
Watson McDaniel UTS600 Series User Guide (Installation, operation & maintenance manual), @GRA9E3 |
6 | 87 | 14 | 16-08-2026 | view all manuals |