3Com 5500-EI PWR Getting Started Manual
Read Online
Read the 3Com 5500-EI PWR Getting Started Manual online using the built-in PDF viewer.
Text of the manual
Part No. DUA1715-0AAA02
Published April 2005
SuperStack® 4
Switch 5500 Family
Getting Started Guide
Switch 5500-SI 28-Port (3CR17151-91)
Switch 5500-SI 52-Port (3CR17152-91)
Switch 5500-EI 28-Port (3CR17161-91)
Switch 5500-EI 52-Port (3CR17162-91)
DUA1715-0AAA02.book Page 1 Wednesday, March 23, 2005 11:17 AM
350 Campus Drive
Marlborough,
MA 01752-3064
Copyright © 2005, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced
in any form or by any means or used to make any derivative work (such as translation, transformation, or
adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time
to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either
implied or expressed, including, but not limited to, the implied warranties, terms or conditions of
merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or
changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy,
please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the software described herein are
provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense.
Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or
as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are
provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights
only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable.
You agree not to remove or deface any portion of any legend provided on any licensed program or
documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com, the 3Com logo and SuperStack are registered trademarks of 3Com Corporation.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows
NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of
Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively
through X/Open Company, Ltd.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
Netscape Navigator is a registered trademark of Netscape Communications.
JavaScript is a trademark of Sun Microsystems.
All other company and product names may be trademarks of the respective companies with which they are
associated.
ENVIRONMENTAL STATEMENT
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we
are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental
standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is
fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and
the inks are vegetable-based with a low heavy-metal content.
ENCRYPTION
This product contains encryption and may require U.S. and/or local government authorization prior to export
or import to another country.
DUA1715-0AAA02.book Page 2 Wednesday, March 23, 2005 11:17 AM
ABOUT THIS GUIDE
Before You Start
7
Release Notes
7
About Your CD-ROM
8
Conventions
8
Related Documentation
9
Accessing Online Documentation
10
Documentation Comments
11
1
INTRODUCING THE
SUPERSTACK 4 SWITCH 5500 FAMILY
About the Switch 5500
14
Summary of Hardware Features
14
Switch 5500 — Front View Detail
15
10BASE-T/ 100BASE-TX Ports
15
1000BASE-X SFP Ports
16
Console Port
16
Unit LED
16
LEDs
16
Switch 5500 — Rear View Detail
18
Power Socket
18
Open Book Warning Labels
18
Redundant Power System Socket
18
Default Settings
19
2
INSTALLING THE SWITCH
Package Contents
22
Choosing a Suitable Site
22
Rack-mounting
23
Connecting a Redundant Power Supply
25
DUA1715-0AAA02.book Page 3 Wednesday, March 23, 2005 11:17 AM
Specifying the Redundant Power System
27
Connecting the Switch to the Redundant Power System
27
Connecting the Earthing Cable
28
RPS LED
29
Placing Units On Top of Each Other
30
The Power-up Sequence
30
Powering-up the Switch 5500
30
Checking for Correct Operation of LEDs
30
SFP Operation
31
Approved SFP Transceivers
31
Inserting an SFP Transceiver
31
Removing an SFP Transceiver
33
Choosing the Correct Cables
33
3
SETTING UP FOR MANAGEMENT
Methods of Managing a Switch
36
Command Line Interface Management
36
Command Line Interface Management using SSH
37
Web Interface Management
37
SNMP Management
37
Setting Up Overview
38
IP Configuration
39
Preparing for Management
40
Manually Configuring IP Information
41
Connecting to the Console Port
41
Connecting to a Front Panel Port
44
Viewing Automatically Configured IP Information
47
Using 3Com Network Director
48
Connecting to the Console Port
48
Setting Up Command Line Interface Management
50
User Interface Overview
50
CLI Management via the Console Port
50
CLI Management over the Network
50
Setting Up Command Line Interface Management using SSH
51
Setting Up Web Interface Management
52
Pre-requisites
52
Web Management Over the Network
53
DUA1715-0AAA02.book Page 4 Wednesday, March 23, 2005 11:17 AM
Setting Up SNMP Management V1 or V2
53
Pre-requisites
54
Default Users and Passwords
54
Configuration Conversion Utility
55
4
CREATING AN XRN STACKING FABRIC
How To Interconnect Units
57
Guidelines For Interconnecting Units
59
Unit Numbering within the Fabric
60
5
PROBLEM SOLVING
Solving Problems Indicated by LEDs
62
Solving Hardware Problems
63
Solving Communication Problems
64
Solving Fabric Formation Problems
66
6
UPGRADING SOFTWARE
Upgrading from the Command Line Interface
68
Introduction
68
TFTP
69
FTP (via a network port)
71
XModem (via the console cable)
72
Upgrading from the Bootrom Interface
73
Introduction
73
TFTP
74
FTP
75
XModem
76
Bootrom Upgrade
77
Bootrom Upgrade via TFTP
77
Bootrom Upgrade via FTP
78
Bootrom Upgrade via XModem
79
A
SAFETY INFORMATION
Power Cord Set — Japan
82
Important Safety Information
82
DUA1715-0AAA02.book Page 5 Wednesday, March 23, 2005 11:17 AM
L’information de Sécurité Importante
85
Wichtige Sicherheitsinformationen
88
Información de Seguridad Importante
90
Importanti Informazioni di Sicurezza
93
Ważne informacje o zabezpieczeniach
96
B
PIN-OUTS
Null Modem Cable
101
PC-AT Serial Cable
101
Modem Cable
102
Ethernet Port RJ-45 Pin Assignments
102
C
TECHNICAL SPECIFICATIONS
Switch 5500-SI
105
Switch 5500-EI
107
RPS
108
Earthing Lead
109
D
OBTAINING SUPPORT FOR YOUR PRODUCT
Register Your Product
111
Purchase Value-Added Services
111
Troubleshoot Online
112
Access Software Downloads
112
Telephone Technical Support and Repair
112
Contact Us
113
INDEX
REGULATORY NOTICES
DUA1715-0AAA02.book Page 6 Wednesday, March 23, 2005 11:17 AM
ABOUT THIS GUIDE
This guide provides all the information you need to install and use the
following switches in their default state:
■
SuperStack® 4 Switch 5500-SI 28-Port (3CR17151-91)
■
SuperStack® 4 Switch 5500-SI 52-Port (3CR17152-91)
■
SuperStack® 4 Switch 5500-EI 28-Port (3CR17161-91)
■
SuperStack® 4 Switch 5500-EI 52-Port (3CR17162-91)
All procedures described in this guide apply to all models except where
stated.
The guide is intended for use by network administrators who are
responsible for installing and setting up network equipment;
consequently, it assumes a basic working knowledge of LANs (Local Area
Networks).
Before You Start
This section contains information about the documents and CD-ROM
that accompany your Switch 5500.
Release Notes
The Release Notes provide important information about the current
software release, including new features, modifications, and known
problems. You should read the Release Notes before installing the Switch
in your network.
If the information in the Release Notes differ from the information in this
guide, follow the instructions in the Release Notes.
DUA1715-0AAA02.book Page 7 Wednesday, March 23, 2005 11:17 AM
ABOUT THIS GUIDE
About Your CD-ROM
The CD-ROM contains the following:
■
Online documentation for the Switch 5500 — refer to Related
Documentation on page 9 for details.
■
A link to 3Com Network Director software.
■
A number of other useful links.
Most user guides and release notes are available in Adobe Acrobat
Reader Portable Document Format (PDF) or HTML on the 3Com
World Wide Web site:
http://www.3com.com/
Conventions
Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons
Icon
Notice Type
Description
Information note
Information that describes important features or
instructions
Caution
Information that alerts you to potential loss of data or
potential damage to an application, system, or device
Warning
Information that alerts you to potential personal injury
Table 2 Text Conventions
Convention
Description
Screen displays
This typeface represents information as it appears on the
screen.
Syntax
The word “syntax” means that you must evaluate the syntax
provided and then supply the appropriate values for the
placeholders that appear in angle brackets. Example:
To change your password, use the following syntax:
system password
In this example, you must supply a password for .
Commands
The word “command” means that you must enter the
command exactly as shown and then press Return or Enter.
Commands appear in bold. Example:
To display IP information, enter the following command:
display ip interface br
DUA1715-0AAA02.book Page 8 Wednesday, March 23, 2005 11:17 AM
In addition to this guide, each Switch documentation set includes the
following:
■
SuperStack 4 Switch Configuration Guide
This guide contains information on the features supported by your
Switch and how they can be used to optimize your network. It is
supplied in PDF format on the CD-ROM that accompanies the Switch.
■
SuperStack 4 Switch Management Quick Reference Guide
This guide contains:
■
a list of the features supported by the Switch.
■
a summary of the command line interface commands for the
Switch. This guide is also available under the Help button on the
web interface.
The words “enter”
and “type”
When you see the word “enter” in this guide, you must type
something, and then press Return or Enter. Do not press
Return or Enter when an instruction simply says “type.”
Keyboard key names
If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+). Example:
Press Ctrl+Alt+Del
Words in italics
Italics are used to:
■
Emphasize a point.
■
Denote a new term at the place where it is defined in the
text.
■
Identify menu names, menu commands, and software
button names. Examples:
From the Help menu, select Contents.
Click OK.
Table 2 Text Conventions (continued)
Convention
Description
DUA1715-0AAA02.book Page 9 Wednesday, March 23, 2005 11:17 AM
ABOUT THIS GUIDE
■
SuperStack 4 Switch Command Reference Guide
This guide provides detailed information about the web interface and
command line interface that enable you to manage the Switch. It is
supplied in PDF format on the CD-ROM that accompanies the Switch.
■
Release Notes
These notes provide information about the current software release,
including new features, modifications, and known problems. The
Release Notes are supplied in hard copy with your Switch.
Accessing Online
Documentation
To access the documentation on the CD-ROM supplied with your Switch,
do the following:
1 Insert the CD-ROM into your CD-ROM drive. If your PC has auto-run
enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
If the online documentation is to be accessed from a local drive or server,
you will need to access the CD-ROM contents via the root directory and
copy the files from the CD-ROM to a suitable directory.
■
The PDF Command Reference Guide is stored in the Docs directory on
the CD-ROM.
■
The PDF Configuration Guide is stored in the Docs directory of the
CD-ROM.
DUA1715-0AAA02.book Page 10 Wednesday, March 23, 2005 11:17 AM
Your suggestions are very important to us. They will help make our
documentation more useful to you. Please e-mail comments about this
document to 3Com at:
[email protected]
Please include the following information when commenting:
■
Document title
■
Document part number (on the title page)
■
Page number (if appropriate)
Example:
Part Number DUA1715-0AAA01
SuperStack 4 Switch 5500 Family Getting Started Guide
Page 21
Please note that we can only respond to comments and questions about
3Com product documentation at this e-mail address. Questions related to
technical support or sales should be directed in the first instance to your
network supplier.
DUA1715-0AAA02.book Page 11 Wednesday, March 23, 2005 11:17 AM
SUPERSTACK 4 SWITCH 5500
FAMILY
This chapter contains introductory information about the Switch 5500
and how it can be used in your network. It covers summaries of hardware
and software features and also the following topics:
■
About the Switch 5500
■
Switch 5500 — Front View Detail
■
Switch 5500 — Rear View Detail
■
Default Settings
DUA1715-0AAA02.book Page 13 Wednesday, March 23, 2005 11:17 AM
CHAPTER 1: INTRODUCING THE SUPERSTACK 4 SWITCH 5500 FAMILY
About the Switch
5500
The Switch 5500 Family are mixed media devices which consist of:
■
24 or 48 10BASE-T/100BASE-TX ports
■
4 1000BASE-X SFP ports
■
1 RJ-45 connector for serial management
■
1 unearthed 48V DC Redundant Power System Input
The Switch 5500 Family provides high-performance workgroups with a
backbone to server connection. You can also add the Switch 5500 Family
to any SuperStack® system as your network grows.
For information about using the software features of the Switch, refer to
the “Command Reference Guide” on the CD-ROM that accompanies the
Switch.
Summary of
Hardware Features
Table 3 summarizes the hardware features that are supported by the
Switch 5500.
Table 3 Hardware Features
Feature
Switch 5500
Addresses
Up to 16,000 supported
Auto-negotiation
Supported on all ports
Forwarding Modes
Store and Forward
Duplex Modes
Half and full duplex on all front panel ports
Auto MDI/MDIX
Supported on all ports. If fiber SFP transceivers are
used, Auto MDIX is not supported.
Flow Control
In full duplex operation all ports are supported
Traffic Prioritization
Supported (using the IEEE Std 802.ID, 1998 Edition):
Eight traffic queues per port
Ethernet Ports
Auto-negotiating 10BASE-T/100BASE-TX ports
SFP Ethernet Ports
Supports fiber Gigabit Ethernet short-wave (SX),
long-wave (LX), long-haul (LH70) and copper (T)
transceivers in any combination.
RPS Support
Connects to unearthed 48v DC supply
Mounting
19-inch rack or stand-alone mounting
XRN
Up to eight units can be managed as a single unit
with one IP address.
DUA1715-0AAA02.book Page 14 Wednesday, March 23, 2005 11:17 AM
Switch 5500 — Front View Detail
15
Switch 5500 —
Front View Detail
Figure 1 Switch 5500-SI and Switch 5500-EI 28-Port — front view
Figure 2 Switch 5500-SI and Switch 5500-EI 52-Port - front view
WARNING: RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot
be used as standard traditional telephone sockets, or to connect the unit to a
traditional PBX or public telephone network. Only connect RJ-45 data
connectors, network telephony systems, or network telephones to these
sockets.
Either shielded or unshielded data cables with shielded or unshielded
jacks can be connected to these data sockets.
10BASE-T/
100BASE-TX Ports
The Switch 5500 has 24 or 48 auto-negotiating 10BASE-T/100BASE-TX
ports configured as Auto MDIX (cross-over). These ports automatically
provide the appropriate connection. Alternatively, you can manually set
these ports to 10BASE-T half duplex, 10BASE-T full duplex, 100BASE-TX
half duplex or 100BASE-TX full duplex. The maximum segment length is
100 m (328 ft) over Category 5 twisted pair cable.
Unit LED
Console Port
Mode LED
Power LED
10/100BASE-TX Ports
Port Status LEDs
1000BASE-X Ports
RPS LED
Unit LED
Console Port
Mode LED
RPS LED
10/100BASE-TX Ports
Port Status LEDs
1000BASE-X Ports
PWR LED
DUA1715-0AAA02.book Page 15 Wednesday, March 23, 2005 11:17 AM
CHAPTER 1: INTRODUCING THE SUPERSTACK 4 SWITCH 5500 FAMILY
1000BASE-X SFP Ports
SFP (Small Form Factor Pluggable) ports support fiber Gigabit Ethernet
short-wave (SX), long-wave (LX), long-haul (LH70) and copper (T) SFP
Transceivers in any combination. This offers you the flexibility of using SFP
transceivers to provide connectivity between the Switch and remote 1000
Mbps workgroups or to create a high capacity aggregated link backbone
connection.
The default state for these ports is auto-negotiation enabled, where the
speed, duplex and flow control modes are negotiated. As the speed and
duplex modes are fixed by the media type, only the flow control is
negotiated with the link partner. Alternatively, auto-negotiation can be
disabled (except 1000BASE-T which auto-neogtiation is mandatory) and
the flow control setting can be manually configured.
Console Port
The console port allows you to connect a terminal and perform remote or
local out-of-band management. As the console port on the Switch is an
RJ-45 port, you will need to connect an RJ-45 to DB9 converter cable to a
standard null modem cable in order to connect a terminal.
Unit LED
The Unit LED is a seven segment display visible on the front of the Switch.
The Unit LED can be used to indicate the unit number in a fabric, POST
test ID and software upgrade information. In the unlikely event of a
hardware fault occurring, the Unit LED may be used to help diagnose the
problem. For information on using the Unit LED for problem solving, see
“Solving Problems Indicated by LEDs” on page 62
LEDs
Table 4 lists LEDs visible on the front of the Switch, and how to read their
status. For information on using the LEDs for problem solving, see
“Solving Problems Indicated by LEDs” on page 62.
Table 4 LED Behavior
LED
Color
Indicates
Unit LED
Green
Power On Self Test (POST) is in progress. During POST a the
test ID number appears in the Unit LED (seven segment
display).
or
Software download is in progress. During software
download, a clockwise cycling bar appears in the Unit LED.
Green flashing
The Switch has failed POST. The Unit LED flashes the
number of the test that has failed.
Green flashing ‘f’ There has been a fan failure.
DUA1715-0AAA02.book Page 16 Wednesday, March 23, 2005 11:17 AM
Switch 5500 — Front View Detail
17
Green flashing ‘t’ The Switch is over temperature and unit temperature is
critical.
PWR LED
Green
The Switch is powered-up and operating normally.
Green flashing
Self Test (POST) or Software Download is in progress.
Yellow flashing
One or more ports have failed POST.
Red
The Switch has failed its Power On Self Test.
Off
The Switch is not receiving power or there is a fault with the
Power Supply Unit.
Mode LED
Speed Green
10/100 Port Speed and Activity, Gigabit SFP Status and
Activity, or Stack Status and Activity.
Duplex Yellow
10/100 Duplex and Activity, Gigabit SFP Duplex and
Activity, or Stack Activity.
RPS LED
Green
AC and RPS supply connected.
Yellow
AC failed or not connected. RPS supply is OK.
Off
There is no RPS supply connected.
10/100BASE-T/TX Port LEDs
Speed Green
A high speed (100 Mbps) link is present, blinking off for
every packet received or transmitted.
Yellow
A low speed (10 Mbps) link is present, blinking off for every
packet received or transmitted.
Yellow Flashing
The port has failed POST.
Off
No link is present.
Duplex Green
Full duplex, blinking off for every packet received or
transmitted.
Yellow
Half duplex, blinking off for every packet received or
transmitted.
Yellow flashing
The port has failed POST.
Off
No link is present.
1000BASE-X Port LEDs
Speed Green
A high speed (1000 Mbps) link is present.
Yellow Flashing
Port failed POST.
Off
No link is present.
Duplex Green
Full duplex packets are being transmitted/received on the
port.
LED
Color
Indicates
DUA1715-0AAA02.book Page 17 Wednesday, March 23, 2005 11:17 AM
CHAPTER 1: INTRODUCING THE SUPERSTACK 4 SWITCH 5500 FAMILY
Switch 5500 — Rear
View Detail
Figure 3 Switch 5500 SI and EI — rear view
Power Socket
The Switch automatically adjusts its power setting to any supply voltage
in the range 100-240 VAC.
Open Book Warning
Labels
Before installing or removing any components from the Switch 5500 or
carrying out any maintenance procedures, you must read the safety
information provided in Appendix A of this guide.
Redundant Power
System Socket
To protect against internal power supply failure, you can use this socket
to connect the Switch to an unearthed 48V DC Redundant Power
System.
Yellow
Half duplex packets are being transmitted/received on the
port.
Yellow flashing
Port failed POST.
Off
No link is present.
LED
Color
Indicates
Power Socket
Redundant Power System Socket
100-240V; 50/60Hz; 1.0A
Open Book Warning Labels
NULL
Earthing Screw
~
-48
-60V;2.0A
DUA1715-0AAA02.book Page 18 Wednesday, March 23, 2005 11:17 AM
Table 5 shows the default settings for the Switch 5500 Family:
Table 5 Default Settings
Feature
Switch 5500
Automatic IP Configuration
Enabled
Port Status
Enabled
Port Speed
Auto-negotiated
Duplex Mode
Auto-negotiated
Flow Control
Auto-negotiated
Broadcast Storm Control
Enabled
Virtual LANs (VLANs)
All ports belong to the untagged Default VLAN
(VLAN 1) with IEEE Std 802.1Q-1998 learning
operational
Management VLAN
Fixed as VLAN 1 on 5500-SI units. Can be any
VLAN for 5500-EI units.
Link Aggregation Control
Protocol (LACP)
Disabled per port
IP Multicast Filtering
Filtering enabled
Rapid Spanning Tree Protocol
Enabled
Fast Start
Enabled on front panel ports
RMON Alarm
Enabled
Webcache Support
Disabled
Traffic Prioritization
All ports prioritize NBX VoIP traffic (LAN and IP).
All ports set to “best effort” for all other traffic.
Port Security
Disabled per port
Configuration Save and
Restore
Disabled
DUA1715-0AAA02.book Page 19 Wednesday, March 23, 2005 11:17 AM
CHAPTER 1: INTRODUCING THE SUPERSTACK 4 SWITCH 5500 FAMILY
DUA1715-0AAA02.book Page 20 Wednesday, March 23, 2005 11:17 AM
INSTALLING THE SWITCH
This chapter contains the information you need to install and set up the
Switch 5500. It covers the following topics:
■
Package Contents
■
Choosing a Suitable Site
■
Rack-mounting
■
Connecting a Redundant Power Supply
■
Placing Units On Top of Each Other
■
The Power-up Sequence
■
SFP Operation
■
Choosing the Correct Cables
WARNING: Safety Information. Before installing or removing any
components from the Switch 5500 or carrying out any maintenance
procedures, you must read the safety information provided in Appendix A
of this guide.
AVERTISSEMENT: Consignes de sécurité. Avant d'installer ou d'enlever
tout composant du Switch 5500 ou d'entamer une procédure de
maintenance, lisez les informations relatives à la sécurité qui se trouvent
dans l'Appendice A de ce guide.
VORSICHT: Sicherheitsinformationen. Bevor Sie Komponenten aus
dem Switch 5500 entfernen oder dem Switch 5500 hinzufuegen oder
Instandhaltungsarbeiten verrichten, lesen Sie die Sicherheitsanweisungen,
die in Appendix A (Anhang A) in diesem Handbuch aufgefuehrt sind.
ADVERTENCIA: Información de seguridad. Antes de instalar o extraer
cualquier componente del Switch 5500 o de realizar tareas de
mantenimiento, debe leer la información de seguridad facilitada en el
Apéndice A de esta guía del usuario.
DUA1715-0AAA02.book Page 21 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
AVVERTENZA: Informazioni di sicurezza. Prima di installare o
rimuovere qualsiasi componente dal Switch 5500 o di eseguire qualsiasi
procedura di manutenzione, leggere le informazioni di sicurezza riportate
nell'Appendice A della presente guida per l'utente.
OSTRZEŻENIE: Informacje o zabezpieczeniach. Przed instalacją lub
usunięciem jakichkolwiek elementów z product lub przeprowadzeniem
prac konserwacyjnych należy zapoznać się z informacjami o
bezpieczeństwie zawartymi w Załączniku A niniejszego podręcznika.
Package Contents
■
Switch unit
■
CD-ROM (includes documentation related to your Switch)
■
Getting Started Guide (this guide)
■
Release Notes
■
Unit Information Labels
■
Warranty Information
■
RPS Flyer
■
Power Cord
■
Console Cable (RJ-45)
■
RPS Connector (and backshell)
■
RPS Connector Cable Tie
■
Earthing Lead
■
2 x Mounting brackets
■
4 x Screws
■
4 x Rubber feet
Choosing a Suitable
Site
The Switch is suited for use on a desktop, either free standing or
mounted in a standard 19-inch equipment rack. Alternatively, the Switch
can be mounted in a wiring closet or equipment room. A rack-mounting
kit containing two mounting brackets is supplied with the Switch.
CAUTION: Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
■
Cabling is located away from:
DUA1715-0AAA02.book Page 22 Wednesday, March 23, 2005 11:17 AM
sources of electrical noise such as radios, transmitters and
broadband amplifiers.
■
power lines and fluorescent lighting fixtures
■
The Switch is accessible and cables can be connected easily.
■
Water or moisture cannot enter the case of the Switch.
■
Air flow is not restricted around the Switch or through the vents in the
side of the Switch. 3Com recommends that you provide a minimum of
25mm (1in.) clearance.
■
Air temperature around the Switch does not exceed 40 °C (104 °F).
If the Switch is installed in a 19-inch rack or closed assembly its local air
temperature may be greater than room ambient temperature.
■
The air is as free from dust as possible.
■
The unit is installed in a clean, air conditioned environment.
■
No more than eight Switch units are placed on top of one another, if
the units are free-standing.
■
The Switch is situated away from sources of conductive (electrical)
dust, for example laser printers.
■
The AC supply used by the Switch is separate to that used by units
that generate high levels of AC noise, for example air conditioning
units and laser printers.
Rack-mounting
The Switch 5500 is 1U high and will fit in most standard 19-inch racks.
CAUTION: Disconnect all cables from the Switch before continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.
To rack-mount your Switch:
1 Place the Switch the right way up on a hard flat surface, with the front
facing towards you.
2 Locate a mounting bracket over the mounting holes on one side of the
front of the Switch, as shown in Figure 4.
You can also rack mount your Switch using the mounting holes at the
rear of the Switch.
DUA1715-0AAA02.book Page 23 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
Figure 4 Fitting a Bracket for Rack-Mounting
3 Insert the two screws and tighten with a suitable screwdriver.
You must use the screws supplied with the mounting brackets. Damage
caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws
(not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Finally place a unit information label on the unit in an easily accessible
position. The unit information label shows the following:
■
3Com product name of the Switch
■
3Com 3C number of the Switch
■
Unique MAC address (Ethernet address) of the Switch
■
Serial number of the Switch
You may need this information if you contact 3Com Technical Support.
DUA1715-0AAA02.book Page 24 Wednesday, March 23, 2005 11:17 AM
Connecting a Redundant Power Supply
25
Connecting a
Redundant Power
Supply
The Switch 5500 has an unearthed 48V DC Redundant Power Supply
socket.
WARNING: The installation of the Redundant Power Supply (RPS) should
only be carried out by properly trained and qualified personnel.
WARNING: These instructions must be read in conjunction with the RPS
flyer and the safety and installation instructions supplied with your RPS.
WARNING: When powering any Switch 5500 from an RPS, the unit must
be earthed (grounded). This can be achieved by either connecting the
power cord to the unit or by connecting the earth terminal on the rear of
the unit to a reliable electrical earth, or by connecting both. You must
ensure that the earth connection is made before connecting the DC
supply from the RPS.
WARNING: Any RPS must be approved as an unearthed SELV output in
accordance with IEC 60950-1/UL 60950-1/EN 60950-1.
WARNING: The characteristics of the Switch 5500 DC supply input are
given in Appendix C on page 105.
The Switch 5500 can be powered in three different ways:
■
AC Mains only — does not offer any power redundancy. If the AC
mains supply or the AC power supply fail, the Switch will power off.
■
AC Mains and Unearthed 48V DC (primary supply) — the internal
AC supply acts as the backup in the event of a DC power failure.
■
DC only — the Switch does not need an AC supply and the resiliency
is provided by the DC supply. This is useful in an environment where
only DC power is available.
The RPS provides two main benefits to the customer:
■
Power Redundancy — if a Switch is powered from the mains supply
unit, a failure of the internal power supply will cause the Switch to fail.
This can be overcome by connecting both the AC and DC RPS supplies
to the Switch. Additional redundancy can also be added to the DC
power by using (N+1) DC power supplies to further increase the
availability of the system.
■
Uninterruptible Power — the system allows easy connection and
maintenance of batteries to the RPS shelf to further increase the
availability of the system.
DUA1715-0AAA02.book Page 25 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
Table 6 below, outlines the behavior of the Switch when changes occur to
the power system, such as removing the AC mains cable when the RPS is
attached. The responses to the different power inputs are controlled by
the Switch’s internal power supply and not by the RPS.
Table 6 Switch Power Inputs
3Com’s RPS solution uses 48V DC power distribution. The RPS system
provides bulk 48V DC power that is separately distributed to a number of
network switches.
Each RPS consists of a shelf which can house from one to six rectifiers, a
Distribution Module and a Management Module.
The RPS generates 48V DC power using power supply units (or rectifiers).
The outputs of the rectifier(s) are connected together so that the total
48V power available can be increased by adding additional rectifiers. For
example, three 1500W rectifiers can provide up to 4500W. Hot removal
or insertion of a rectifier will not affect the 48V DC output voltage.
Table 7 shows an example of the total power available from a number of
1500W rectifiers.
A minimum of two rectifiers are required for each shelf to provide N+1
rectifier redundancy.
Power Input before
User Intervention
Power Input after
User Intervention
Correct Response
AC mains and RPS
RPS only
The unit remains powered by the RPS.
AC mains and RPS
AC mains only
The unit is powered by the AC mains.
RPS only
AC mains and RPS
The unit remains powered by the RPS.
AC mains
AC mains and RPS
The unit is powered by the RPS.
DUA1715-0AAA02.book Page 26 Wednesday, March 23, 2005 11:17 AM
Connecting a Redundant Power Supply
27
Table 7 Power Availability
The unearthed 48V DC power distribution provides the mechanism to
connect to the Switch 5500. The distribution consists of a number of
circuit breakers and connection terminals for the positive (common) and
negative 48V outputs. Each Switch 5500 must be individually connected
to a circuit breaker terminal.
A battery can also be connected to battery terminals prior to the DC
power distribution to provide uninterrupted power in order to protect
against the loss of AC mains power.
Specifying the
Redundant Power
System
For an approved vendor list, more details about purchasing the RPS and a
full set of requirements go to:
http://www.3Com.com/RPS
3Com’s redundant power solution allows the use of any off-the-shelf 48V
DC RPS that provides an ‘unearthed SELV’ output in compliance with IEC
60950-1/UL 60950-1/EN 60950-1, as defined in Appendix C on
page 105.
Connecting the
Switch to the
Redundant Power
System
When connecting the RPS to the Switch, the circuit breaker and 2-core
cable need to be matched to the power rating of the Switch. Table 8
shows the recommended circuit breaker and cable rating for the Switch
5500. The recommended cable length should not exceed 3 metres (9.84
feet).
Table 8 Switch 5500 Circuit Breaker and Cable Rating
Rectifiers
1
2
3
4
5
6
No Rectifier
Redundancy
1500W
3000W
4500W
6000W
7500W
9000W
N+1 Rectifier
Redundancy
-
1500W
3000W
4500W
6000W
7500W
Circuit Breaker
Minimum 2-Core Cable Diameter
Switch 5500
6A C type
18AWG (solid or stranded cable)
DUA1715-0AAA02.book Page 27 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
Connecting the
Earthing Cable
Use the earthing cable that accompanies your Switch if the length is
suitable, alternatively use the earthing cable specification as defined in
Appendix C on page 105.
The recommended cable length should not exceed 3 metres (9.84 feet).
WARNING: RPS Manufacturers recommendations must be followed
when connecting the cable to the RPS.
WARNING: Ensure that the circuit breaker in the RPS is in the open (off)
position when connecting the cable to the RPS.
WARNING: You must ensure that the positive terminal on the Switch is
connected to the positive (common) terminal of the RPS and that the
negative terminal on the Switch is connected to the negative (circuit
breaker) terminal of the RPS.
WARNING: Ensure that the circuit breaker in the RPS is in the open (off)
position when connecting the RPS cable and connector to the Switch.
Figure 5 shows how to connect the power supply to the RPS socket in the
back of the Switch. Use the cable tie supplied with your Switch to support
the cable at the rear of the RPS connector as shown.
DUA1715-0AAA02.book Page 28 Wednesday, March 23, 2005 11:17 AM
Connecting a Redundant Power Supply
29
Figure 5 RPS Connection to the Switch
When the RPS is connected to the Switch, the circuit breaker in the RPS
can be moved to the closed (on) position and the Switch will be powered
by the 48V DC power.
The 48V DC power will take priority over the AC mains and will power
the Switch if it is connected.
RPS LED
The RPS status LED on the front of the Switch 5500 indicates the status of
the RPS and AC supplies as shown in Table 9.
Table 9 RPS LED Colors
+ - NULL
-48
-60V;2.0A
100-240V;50/60Hz;1.0A
~
NULL
-48 -60V;2 0A
Null
+
-
Pinout
Cable Tie
Color
State
Green
AC and RPS supply connected.
Yellow
AC failed or not connected. RPS supply is ok.
Off
There is no RPS supply connected.
DUA1715-0AAA02.book Page 29 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
Placing Units On
Top of Each Other
If the Switch units are free-standing, up to eight units can be placed one
on top of the other. If you are mixing a variety of SuperStack® units, the
smaller units must be positioned at the top.
If you are placing Switch units one on top of the other, you must use the
self-adhesive rubber feet supplied. Apply the feet to the underside of
each Switch, sticking one in the marked area at each corner. Place the
Switch units on top of each other, ensuring that the feet of the upper unit
sit fully on the lower unit.
The Power-up
Sequence
The following sections describe how to get your Switch 5500
powered-up and ready for operation.
Powering-up the
Switch 5500
Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST),
which takes approximately one minute.
Checking for Correct
Operation of LEDs
During the Power On Self Test, all ports on the Switch are disabled and
the LEDs light. The PWR LED will flash green during the POST.
When the POST has completed, check the PWR LED to make sure that
your Switch is operating correctly. Table 10 shows possible colors for the
LED.
Table 10 PWR LED Colors
Color
State
Green
The Switch is powered-up and operating normally.
Red
The Switch has failed its Power On Self Test (POST).
Yellow flashing
Some ports have failed POST*
* In this event you can still use the Switch via the remaining ports that have passed the
POST.
Off
The Switch is not receiving power.
DUA1715-0AAA02.book Page 30 Wednesday, March 23, 2005 11:17 AM
If there is evidence of a problem, see “Solving Problems Indicated by
LEDs” on page 62 for a list of suggested solutions.
CAUTION: The Switch has no ON/OFF switch; the only method of
connecting or disconnecting mains power is by connecting or
disconnecting the power cord.
SFP Operation
The following section describes how to insert an SFP transceiver into an
SFP port.
SFP transceivers are hot-insertable and hot-swappable. You can remove
them from and insert them into any SFP port without having to power
down the Switch.
You will need to install an SFP transceiver if you wish to create an XRN
Distributed Fabric as an SFP port is used to interconnect the Switches.
Approved SFP
Transceivers
The following list of approved Gigabit Ethernet SFP transceivers is correct
at the time of publication.
■
3CSFP91 SFP (1000BASE-SX)
■
3CSFP92 SFP (1000BASE-LX)
■
3CSFP97 SFP (1000BASE-LH70)
■
3CSFP93 SFP (1000BASE-T)
To access the latest list of approved SFP transceivers for the Switch on the
3Com Corporation World Wide Web site, enter this URL into your
internet browser:
http://www.3com.com
Inserting an SFP
Transceiver
To be recognized as valid, the SFP transceiver must have the following
characteristics:
■
1000BASE-SX SFP transceiver
Use this transceiver to connect Gigabit Ethernet SFP ports on the
Switch directly to a multi-mode fiber-optic cable.
■
1000BASE-LX SFP transceiver
DUA1715-0AAA02.book Page 31 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
Use this transceiver to connect Gigabit Ethernet SFP ports on the
Switch directly to a single-mode fiber-optic cable or to multimode
fiber using a conditioned launch cable.
■
1000BASE-LH70 SFP transceiver
Use this transceiver to connect Gigabit Ethernet SFP ports on the
Switch directly to a single-mode fiber-optic cable.
■
1000BASE-T SFP transceiver
This transceiver uses Category 5 copper cabling with RJ-45 connectors
and supports segment lengths of up to 100 m (328 ft).
If the SFP transceiver is faulty, it will not operate within the Switch. See
“Solving Hardware Problems” on page 63.
3Com recommends that you only use SFPs supplied by 3Com. If the SFP
transceiver is invalid it will not be recognized by the Switch.
Use the following sequence of steps to activate the SFP ports:
1 The SFP transceiver is keyed and there is only one way in which it can be
installed correctly. It is not necessary to power-down your Switch.
2 Hold the transceiver so that the connector is toward you and the product
label is visible. Ensure the wire release lever is closed (in the upright
position).
3 Gently slide the transceiver into the SFP port until it clicks. If the
transceiver does not click into place, remove it, turn it over and re-insert.
4 Remove the plastic protective cover if fitted.
Figure 6 Inserting an SFP Transceiver
DUA1715-0AAA02.book Page 32 Wednesday, March 23, 2005 11:17 AM
Choosing the Correct Cables
33
5 Use an appropriate cable to connect the transceiver to a suitable device.
6 Check the LEDs on the front of the Switch to ensure that it is operating
correctly. Refer to “LEDs” on page 16 for more information.
Removing an SFP
Transceiver
If you wish to remove the transceiver (it is not necessary to power-down
your Switch):
1 Disconnect the cable from the transceiver.
2 Move the wire release lever downwards until it is pointing toward you.
3 Pull the wire release lever toward you to release the catch mechanism;
the transceiver will then easily slide out.
Choosing the
Correct Cables
All of the ports on the Switch are Auto-MDIX, that is they have a
cross-over capability. These ports can automatically detect whether to
operate in MDI or MDIX mode. Therefore you can make a connection to
one of the ports with a straight-through (MDI) or a cross-over cable
(MDIX).
The Auto-MDIX feature only operates when auto-negotiation is enabled.
If auto-negotiation is disabled, all the Switch ports are configured as
MDIX (cross-over). If you want to make a connection to another MDIX
port, you need a cross-over cable. Many ports on workstations and
servers are configured as MDI (straight-through). If you want to make a
connection to an MDI port, you need to use a standard straight-through
cable. See Table 11.
Product
label
Suitable port
on host Switch
DUA1715-0AAA02.book Page 33 Wednesday, March 23, 2005 11:17 AM
CHAPTER 2: INSTALLING THE SWITCH
3Com recommends that you use at least Category 5 twisted pair cable —
the maximum segment length for this type of cable is 100 m (328 ft.).
Table 11 Cables required to connect the Switch to other devices if
auto-negotiation is disabled
CAUTION: If you want to install the Switch using a Category 5E or
Category 6 cable, 3Com recommends that you briefly connect the cable
to a grounded port before connecting network equipment. If you do not,
the cable’s Electrostatic Discharge (ESD) may damage the Switch's port.
You can create a grounded port by connecting all wires at one end of a
UTP cable to an earth ground point, and the other end to a female RJ-45
connector located, for example, on a Switch rack or patch panel. The
RJ-45 connector is now a grounded port.
3Com recommends that you use Category 5 twisted pair cable — the
maximum segment length for this type of cable is 100 m (328 ft).
Cross-over Cable
Straight-through Cable
Switch to Switch
(MDIX to MDIX)
✓
✕
Switch to Hub
(MDIX to MDIX)
✓
✕
Switch to PC (NIC)
(MDIX to MDI)
✕
✓
DUA1715-0AAA02.book Page 34 Wednesday, March 23, 2005 11:17 AM
SETTING UP FOR MANAGEMENT
To make full use of the features offered by your Switch, and to change
and monitor the way it works, you have to access the management
software that resides on the Switch. This is known as managing the
Switch.
Managing the Switch can help you to improve the efficiency of the
Switch and therefore the overall performance of your network.
This chapter explains the initial set up of the Switch and the different
methods of accessing the management software to manage a Switch. It
covers the following topics:
■
Methods of Managing a Switch
■
Setting Up Overview
■
Manually Configuring IP Information
■
Viewing Automatically Configured IP Information
■
Setting Up Command Line Interface Management
■
Setting Up Command Line Interface Management using SSH
■
Setting Up Web Interface Management
■
Setting Up SNMP Management V1 or V2
■
Default Users and Passwords
■
Configuration Conversion Utility
DUA1715-0AAA02.book Page 29 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
Methods of
Managing a Switch
To manage your Switch you can use one of the following methods:
■
Command line interface management
■
Command line interface management using SSH
■
Web interface management
■
SNMP management
Command Line
Interface
Management
Each Switch has a command line interface (CLI) that allows you to
manage the Switch from a workstation, either locally via a console port
connection (see Figure 7), or remotely over the network (see Figure 8).
Figure 7 CLI Management via the Console Port
Figure 8 CLI Management over the Network
Refer to “Setting Up Command Line Interface Management” on
page 44.
There are two main views in the CLI:
User View — this view is shown when you first connect to the Switch
and shows basic information about operation and statistics. The prompt
for user view is (where xx is either SI or EI).
System View — this view enables you to configure the system
parameters. To display this view, from user view enter system-view.
The prompt for system view is [SW5500-XX].
Console Port
Connection
Workstation
(with terminal emulation
software installed)
Console Cable
Switch
Switch
Workstation
Connect over Network
via Telnet
DUA1715-0AAA02.book Page 30 Wednesday, March 23, 2005 11:17 AM
Methods of Managing a Switch
31
Command Line
Interface
Management using
SSH
The Switch 5500 supports Secure Shell version 1.5 (SSHv1.5), allowing
secure access to the Command Line Interface of the Switch.
If you use SSH to administer your Switch and the network traffic is
intercepted, no passwords or configuration information will be visible in
the data. To securely administer the Switch using the Command Line
Interface you need a third party SSH client.
Web Interface
Management
Each Switch has an internal set of web pages that allow you to manage
the Switch using a Web browser remotely over an IP network (see
Figure 9).
Figure 9 Web Interface Management over the Network
Refer to “Setting Up Web Interface Management” on page 46.
SNMP Management
You can manage a Switch using any network management workstation
running the Simple Network Management Protocol (SNMP) as shown in
Figure 10. For example, you can use the 3Com Network Director
software, available from the 3Com website.
Figure 10 SNMP Management over the Network
Refer to “Setting Up SNMP Management V1 or V2” on page 47.
Switch
Workstation
Connect over Network
via web browser
Switch
SNMP Network Management
Workstation
Connect over Network
using SNMP
DUA1715-0AAA02.book Page 31 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
Setting Up
Overview
This section gives an overview of what you need to do to get your Switch
set up and ready for management when it is in its default state. The
whole setup process is summarized in Figure 11. Detailed procedural
steps are contained in the sections that follow. In brief, you need to:
■
Configure IP information manually for your Switch or view the
automatically configured IP information
■
Prepare for your chosen method of management
Figure 11 Initial Switch Setup and Management Flow Diagram
Plug and Play Setup
Initial IP Information Setup
Feature Management
Power Up the Switch.
IP Information is automatically configured via
DHCP
See page 33
Do you want to manually
configure the IP information?
Connect to the con-
sole port and use the
Command Line Inter-
face.
See page 35
How do you want to manage your Switch? See
SNMP
See page 47
Command Line Interface
Connect via the
console port.
See page 44
Web Interface
Connect over the
network via Telnet.
See page 44
Connect over the
network.
See page 47
How do you want to view the automatically
configured IP information?
How do you want to connect to the Switch?
Connect to a front panel port
and use the Web Interface or
Command Line
Interface.
See page 35
Use 3Com Network
Director (3ND).
See page 42
Connect to the console
port and use the
Command Line
Interface.
See page 42
Yes
No
DUA1715-0AAA02.book Page 32 Wednesday, March 23, 2005 11:17 AM
Setting Up Overview
33
CAUTION: To protect your Switch from unauthorized access, you must
change all three default passwords as soon as possible, even if you do not
intend to actively manage your Switch. For more information on default
users and changing default passwords, see “Default Users and
Passwords” on page 48.
IP Configuration
You can use one of the following methods to allocate IP information to
your Switch (essential if you wish to manage your Switch across the
network).
Manual IP Configuration
When you configure the IP information, the Switch remembers the
information that you enter until you change it again.
You should use the Manual IP configuration method if:
■
you do not have a DHCP or BootP server on your network, or
■
you want to remove the risk of the IP address ever changing, or
■
your DHCP or BootP server does not allow you to allocate static IP
addresses. (Static IP addresses are necessary to ensure that the Switch
is always allocated the same IP information.)
For most installations, 3Com recommends that you configure the Switch
IP information manually. This makes management simpler and more
reliable as it is not dependent on a DHCP or BootP server, and eliminates
the risk of the IP address changing.
To manually enter IP information for your Switch, work through the
“Manually Configuring IP Information” section on page 35.
Automatic IP Configuration via DHCP
By default the Switch tries to configure itself with IP Information without
requesting user intervention. It tries to obtain an IP address from a DHCP
server on the network.
When using automatic IP configuration it is important that the IP address
of the Switch is static, otherwise you will not know what the IP address is
and it will be difficult to manage. Most DHCP servers allow static IP
addresses to be configured so that you know what IP address will be
allocated to the Switch. Refer to the documentation that accompanies
your DHCP server.
DUA1715-0AAA02.book Page 33 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
For a detailed description of how automatic IP configuration operates,
please refer to the Configuration Guide on the CD-ROM that
accompanies your Switch or the 3Com Web Site.
You should use the automatic IP configuration method if:
■
your network uses DHCP to allocate IP information, or
■
flexibility is needed. If the Switch is deployed onto a different subnet,
it will automatically reconfigure itself with an appropriate IP address,
instead of you having to manually reconfigure the Switch.
If the Switch is not allocated with an automatic IP addresss, the IP
configuration will be blank or shown as ‘’’’.
If you use the automatic IP configuration method, you need to discover
the automatically allocated IP information before you can begin
management. Work through the “Viewing Automatically Configured IP
Information” section on page 41.
Preparing for
Management
Once your Switch’s initial set up is complete you can set up your chosen
management method as described in “Methods of Managing a Switch”
on page 30.
For detailed information about the specific web interface operations and
command line interface commands and problem solving, refer to the
“SuperStack 4 Switch Command Reference Guide” on the CD-ROM that
is supplied with the Switch or on the 3Com Web site.
DUA1715-0AAA02.book Page 34 Wednesday, March 23, 2005 11:17 AM
Manually Configuring IP Information
35
Manually
Configuring IP
Information
You can manually configure the Switch IP information in the following
ways:
■
Connecting to the console port — connect a workstation using a
console cable to the console port of the Switch. You can then
manually enter IP information using the command line interface (CLI).
■
Connecting to a front panel port — connect a workstation using an
Ethernet cable to a front panel port of the Switch. You can then
manually enter IP information using the web interface or the
command line interface (CLI).
Connecting to the
Console Port
To set up your Switch manually you can make a connection to the console
port, (this example describes a local connection to the console port,
rather than one via a modem). You can do this whilst the Switch is offline,
that is, before you connect the Switch to a network, or whilst the Switch
is online, that is, connected to a network.
Pre-requisites
■
A workstation with terminal emulation software installed, such as
Microsoft Hyperterminal. This software allows you to communicate
with the Switch via the console port directly.
■
Documentation supplied with the terminal emulation software.
■
The console cable (RJ-45) supplied with your Switch.
You can find pin-out diagrams for the cable in Appendix B on page 101.
■
You need to have the following so that you can manually set up the
Switch with IP information:
■
IP address
■
subnet mask
■
default gateway
■
management VLAN ID, normally set to the default value (1)
DUA1715-0AAA02.book Page 35 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
Connecting the Workstation to the Switch
1 Connect the workstation to the console port using the console cable as
shown in Figure 12.
Figure 12 Connecting a Workstation to the Switch via the Console Port
To connect the cable:
a Attach the RJ-45 connector on the cable to the console port of the
Switch.
b Attach the other end of the cable to the workstation and tighten the
retaining screws on the cable to prevent it from being loosened.
2 Open your terminal emulation software and configure the COM port
settings to which you have connected the cable. The settings must be set
to match the default settings for the Switch, which are:
■
19,200 baud (bits per second)
■
8 data bits
■
no parity
■
1 stop bit
■
no hardware flow control
Refer to the documentation that accompanies the terminal emulation
software for more information.
3 Power up the Switch. The Power on Self Test (POST) will now be
performed.
Setting Up the Switch with IP Information
You are now ready to manually set up the Switch with IP information
using the command line interface.
1 The command line interface login sequence begins as soon as the Switch
detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times
until it starts.
Console Port
Connection
Workstation
(with terminal emulation
software installed)
Console Cable
Switch
DUA1715-0AAA02.book Page 36 Wednesday, March 23, 2005 11:17 AM
Manually Configuring IP Information
37
2 At the login and password prompts, enter admin as your user name and
press Return and at the password prompt press Return again. If you have
logged on correctly, <5500-xx> should be displayed (where xx is either
SI or EI) as shown in Figure 13.
Once you have logged in you will automatically be in User View.
Figure 13 User View Login
3 Enter the system-view command and Enter.
To confirm that you are in the System View, the following should be
displayed:
[5500-xx]
(where xx is either SI or EI)
4 Enter interface vlan 1 and Enter.
5 Enter the IP address and subnet mask for the Switch as follows:
ip address xxx.xxx.xxx.xxx mmm.mmm.mmm.mmm
and Enter.
(where xxx.xxx.xxx.xxx is the IP address and mmm.mmm.mmm.mmm is
the subnet mask of the Switch)
6 Select the quit command and enter the default gateway for the Switch:
ip route-static 0.0.0.0 0.0.0.0 xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the default gateway)
7 From the User View, enter the save command to save the configuration
to your Switch as the configuration is not saved automatically when the
Switch is powered down.
DUA1715-0AAA02.book Page 37 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
The initial set up of your Switch is now complete and the Switch is ready
for you to set up your chosen management method. See “Methods of
Managing a Switch” on page 30.
If you do not intend to use the command line interface via the console
port to manage the Switch, you can disconnect the serial cable and close
the terminal emulator software.
Connecting to a Front
Panel Port
To set up your Switch manually you can, alternatively, make a connection
to a front panel port. To do this you will need an IP address, refer to
“Viewing Automatically Configured IP Information” on page 41 for more
information.
The procedure described in this section assumes the unit has been
powered up in standalone mode.
Pre-requisites
■
A workstation running a suitable operating system — refer to
“Choosing a Browser” on page 46.
■
A Network Interface Card (NIC).
■
A Category 5 twisted pair Ethernet cable with RJ-45 connectors at
both ends.
■
A suitable Web browser — refer to “Choosing a Browser”on page 46.
■
Existing IP address of the Switch.
■
You need to have the following so that you can manually set up the
Switch with IP information:
■
IP address
■
subnet mask
■
default gateway
■
management VLAN ID, normally set to the default value (1)
DUA1715-0AAA02.book Page 38 Wednesday, March 23, 2005 11:17 AM
Manually Configuring IP Information
39
Connecting the Workstation to the Switch
1 Connect the workstation to a front panel port using an Ethernet cable as
shown in Figure 14.
Figure 14 Connecting a Workstation to the Switch via a Front Panel Port
To connect the cable:
a Attach an RJ-45 connector at one end of the Ethernet cable to the
Network Interface Card (NIC) in the workstation.
b Connect the RJ-45 connector at the other end of the cable to one of
the front panel ports on the Switch.
Do not interconnect the Switch to any other unconfigured Switch.
Setting Up the Switch with IP Information
You are now ready to manually set up the Switch with IP information. You
can do this using the Web interface or the command line interface (CLI)
via telnet.
Using the Web Interface
1 Power-up the Switch. This takes approximately one minute.
2 Open a suitable Web browser and enter the IP address of your Switch in
the Address field.
If there is no response, wait for one minute then re-enter the IP address.
If a pop up message appears displaying download and install simplified
Chinese information, click Cancel.
3 At the login and password prompts, enter admin as your user name and
press Return and at the password prompt (default user name and
password) press Return again. If you have logged on correctly, the Device
View of the Switch is displayed.
Front Panel
Port Connection
Ethernet Cable
Workstation
(with a Network
Interface Card
installed)
Switch
DUA1715-0AAA02.book Page 39 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
4 To enter basic setup information for the Switch, select Administration > IP
Setup and then follow the wizard through various system screens to enter
the IP address and subnet mask that you want the Switch to use when it
is connected to the network. The final page displays a summary of the
information entered.
5 Select Save Configuration to save the configuration to your Switch.
The initial set up of your Switch is now complete and the Switch is ready
for you to set up your chosen management method. See “Methods of
Managing a Switch” on page 30.
Using Command Line Interface via Telnet
1 To start a Telnet session to the unit, click Start in Microsoft Windows
95/98/2000/NT/XP.
a Click Run.
b In the dialogue box that appears type the IP address of the unit, that
is: Telnet xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
c
Click OK.
2 Press Enter to open a login prompt.
If the login prompt does not begin immediately, press Return a few times
until it starts.
3 At the login and password prompts, enter admin as your user name and
press Return at the password prompt. If you have logged on correctly,
<5500-xx> is displayed (where xx is either SI or EI) as shown in the
example in Figure 15.
DUA1715-0AAA02.book Page 40 Wednesday, March 23, 2005 11:17 AM
Viewing Automatically Configured IP Information
41
Figure 15 User View Login via Telnet
4 Enter the system-view command and Enter.
5 Enter interface vlan 1 and Enter.
6 Enter the IP address and subnet mask for the Switch as follows:
ip address xxx.xxx.xxx.xxx mmm.mmm.mmm.mmm
(where xxx.xxx.xxx.xxx is the IP address and mmm.mmm.mmm.mmm is
the subnet mask of the Switch)
7 Enter the default gateway for the Switch:
ip route-static 0.0.0.0 0.0.0.0 xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the default gateway)
8 From the User View, enter the save command to save the configuration
to your Switch as the configuration is not saved automatically when the
Switch is powered down.
The initial set up of your Switch is now complete and the Switch is ready
for you to set up your chosen management method. See “Methods of
Managing a Switch” on page 30.
Viewing
Automatically
Configured IP
Information
If you allow the Switch to automatically configure its own IP information
you need to discover and view the IP information before you can begin to
manage the Switch. You can discover the IP information in two ways:
■
Using 3Com Network Director — this application will auto-discover
the Switch and display the automatically allocated IP information
assigned to the Switch.
DUA1715-0AAA02.book Page 41 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
■
Connecting to the Console Port — connect a workstation using a
console cable to the console port of the Switch. You can then view the
IP information automatically assigned to the Switch using the
command line interface (CLI).
Using 3Com Network
Director
You can use the 3Com Network Director application (available from the
3Com website) to discover the automatically allocated IP information.
1 Connect your Switch to the network.
2 Power-up the Switch and wait for two minutes.
3 Launch 3Com Network Director and run the Auto-discovery wizard.
3Com Network Director will auto-discover the new Switch and display
the IP information that has been automatically allocated to the Switch.
Most DHCP and BootP servers allow static IP addresses to be configured
so that you know what IP address the Switch will be given. Refer to the
documentation that accompanies your DHCP or BootP server.
If your network does not have a DHCP or BootP server, the workstation
running 3Com Network Director must be on the same subnet as the
Switch, because Auto-IP addresses are non-routable.
Connecting to the
Console Port
Alternatively, you can view the automatically configured IP information
via the command line interface (CLI) through a connection to the console
port. (This example describes a local connection to the console port,
rather than a remote one via a modem.) For further information on
connecting via the console port see “Connecting the Workstation to the
Switch”on page 36.
Viewing IP Information via the Console Port
You are now ready to view the automatically allocated IP information
using the command line interface.
1 Connect your Switch to the network using the Ethernet cable. As soon as
a network connection is made the Switch begins the automatic IP
configuration process.
The automatic IP configuration process usually completes within one
minute.
2 The command line interface login sequence begins as soon as the Switch
detects a connection to its console port.
DUA1715-0AAA02.book Page 42 Wednesday, March 23, 2005 11:17 AM
Viewing Automatically Configured IP Information
43
If the login prompt does not begin immediately, press Return a few times
until it starts.
3 At the login and password prompts, enter admin as your user name and
press Return at the password prompt. If you have logged on correctly,
<5500-xx> is displayed (where xx is either SI or EI) as shown in the
example in Figure 16.
Figure 16 User View Login
4 Enter display ip interface br to view a summary of allocated IP
addresses.
The initial set up of your Switch is now complete and the Switch is ready
for you to set up your chosen management method. See “Methods of
Managing a Switch” on page 30.
If you do not intend to use the command line interface via the console
port to manage the Switch, you can logout, disconnect the serial cable
and close the terminal emulator software.
DUA1715-0AAA02.book Page 43 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
Setting Up
Command Line
Interface
Management
This section describes how you can set up command line interface
management using a local console port connection or over the network.
User Interface
Overview
User interface configuration is provided by the Switch to configure and
manage the port data. There are two types of user interfaces:
AUX User Interface — used to log in to your Switch via the console port.
A fabric can have up to eight AUX user interfaces.
VTY User Interface — used to Telnet to the Switch. The Switch can have
up to five VTY user interfaces.
CLI Management via
the Console Port
To manage a Switch using the command line interface via the local
console port connection:
1 Ensure you have connected your workstation to the console port correctly
as described in “Connecting to the Console Port” on page 35.
2 Your Switch is now ready to continue being managed and/or configured
through the CLI via its console port.
CLI Management over
the Network
To manage a Switch using the command line interface over a network
using Telnet:
1 Ensure you have already set up the Switch with IP information as
described in “Methods of Managing a Switch” on page 30.
2 Check that you have the IP protocol correctly installed on your
management workstation. You can check this by trying to browse the
World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping
command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been
entered correctly and the Switch is powered up.
4 To open a Telnet session via the DOS prompt, enter the IP address of the
Switch that you wish to manage in the following format:
>telnet xxx.xxx.xxx.xxx
DUA1715-0AAA02.book Page 44 Wednesday, March 23, 2005 11:17 AM
Setting Up Command Line Interface Management using SSH
45
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
If opening a Telnet session via third party software you will need to enter
the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and
press Return at the password prompt (or the password of your choice if
you have already modified the default passwords).
If the login prompt does not display immediately, press Return a few
times until it starts.
6 If you have logged on correctly, the Switch you wish to manage is
displayed as <5500-xx> (where xx is either SI or EI, as shown in
Figure 13 on page 37).
Setting Up
Command Line
Interface
Management using
SSH
This section describes how you can set up Command Line Interface
management using SSH over a network.
To manage a Switch using the command line interface over a network
using SSH:
1 Ensure you have already set up the Switch with IP information as
described in “Methods of Managing a Switch” on page 30.
2 Check that you have the IP protocol correctly installed on your
management workstation. You can check this by trying to browse the
World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping
command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been
entered correctly and the Switch is powered up.
The switch automatically generates a host key pair when it is powered up
for the first time, or after any reset to factory defaults. Host key
generation may take a while, during which time SSH connections to the
switch will be refused.
4 Install an SSH client application on the workstation you want to use to
access the switch.
3Com recommends the following SSH clients; PuTTY, OpenSSH and SSH
Communications Security Corp Secure Shell.
DUA1715-0AAA02.book Page 45 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
5 Open an SSH session and access the Switch using the Switch’s IP address
and port number.
The first time you connect to the switch the client will ask you to confirm
that the host key is correct for the device.
6 The Switch and the SSH client will authenticate each other and a secure
connection will be established.
7 Enter your usual username and password to access the CLI commands.
For increased security please change the default password when using
SSH for the first time.
For further information on generating a host key on your switch and
transferring keys to the Switch using TFTP server please refer to the
Configuration Guide that is supplied with your Switch.
Setting Up Web
Interface
Management
This section describes how you can set up web interface management
over the network.
Pre-requisites
■
Ensure you have already set up the Switch with IP information as
described in “Methods of Managing a Switch” on page 30.
■
Ensure that the Switch is connected to the network using a Category
5 twisted pair Ethernet cable with RJ-45 connectors.
■
A suitable Web browser.
Choosing a Browser
To display the web interface correctly, use one of the following Web
browser and platform combinations:
Table 12 Supported Web Browsers and Platforms
Windows
2000
Windows XP
Windows
Server 2003
Red Hat
Linux 9
Solaris
7/9
Netscape 7.1
✓
✓
✕
✕
✓
Internet Explorer 5.5
✓
✓
✓
✕
✕
Internet Explorer 6.0
✓
✓
✓
✕
✕
Mozilla 1.4
✕
✕
✕
✓
✓
DUA1715-0AAA02.book Page 46 Wednesday, March 23, 2005 11:17 AM
Setting Up SNMP Management V1 or V2
47
For the browser to operate the web interface correctly, JavaScript™ and
Cascading Style Sheets must be enabled on your browser. These features
are enabled on a browser by default. You will only need to enable them if
you have changed your browser settings.
Web Management
Over the Network
To manage a Switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your
management workstation. You can check this by trying to browse the
World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the Switch by entering a ping
command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been
entered correctly and the Switch is powered up.
3 Open your web browser and enter the IP address of the Switch that you
wish to manage in the URL locator, for example, in the following format:
http://xxx.xxx.xxx.xxx
4 At the login and password prompts, enter admin as your user name and
press Return at the password prompt (or the password of your choice if
you have already modified the default passwords).
5 Click on the Device View button to display the web management options.
Setting Up SNMP
Management V1 or
V2
Any network management application running the Simple Network
Management Protocol (SNMP) can manage a Switch if:
■
The correct Management Information Bases (MIBs) are installed on the
management workstation.
■
The management workstation is connected to the Switch using a port
in VLAN 1 (the Default VLAN). By default, all ports on the Switch are in
VLAN 1.
You can use the 3Com Network Director application that is available from
the 3Com website to provide SNMP management for your Switch. If you
use 3Com Network Director it automatically loads the correct MIBs and
necessary files onto your workstation.
DUA1715-0AAA02.book Page 47 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
Pre-requisites
■
Documentation supplied with the SNMP network management
application software.
The default read community string is public. To change this setting in
System View, enter display snmp community.
The default write community string is private. To change this setting in
System View, enter display snmp community.
To manage your Switch using an SNMP network management
application, you need to specify SNMP community strings for the users
defined on the Switch. You can do this using the command line interface
system management snmp community command — refer to the
command line interface section of the “SuperStack 4 Switch Command
Reference Guide” for more information.
SNMP V3 is on as default. All commands are in snmp menu in System
View.
Default Users and
Passwords
If you intend to manage the Switch using the web interface or the
command line interface, or to change the default passwords, you need to
log in with a valid user name and password. The Switch has three default
user names, and each user name has a different password and level of
access. These default users are listed in Table 13.
CAUTION: To protect your Switch from unauthorized access, you must
change all three default passwords as soon as possible, even if you do not
intend to actively manage your Switch.
Table 13 Default Users
User
Name
Default
Password
Access Level
monitor
monitor
monitor — the user can view all manageable parameters,
except special/security features, but cannot change any
manageable parameters
manager
manager
manager — the user can access and change the
operational parameters but not special/security features
admin
(no
password)
security — the user can access and change all manageable
parameters
DUA1715-0AAA02.book Page 48 Wednesday, March 23, 2005 11:17 AM
Configuration Conversion Utility
49
Use the admin default user name (no password) to login and carry out
initial Switch setup.
To set a password for the admin user in the CLI, enter the following from
system view:
[5500-xx]local-user admin
[5500-xx-luser-admin]password simple xxxxxxxx
(where xxxxxxxx is your chosen password).
Save the configuration in the User View.
For information on the lost password procedure please refer to the
Configuration Guide that is supplied with your Switch.
Configuration
Conversion Utility
The 3Com Switch 5500 Configuration Conversion Utility (CCU) enables
you to convert the key configuration parameters from a range of 3Com
SuperStack II and SuperStack 3 devices to the configuration file format
used by your Switch 5500 unit. The utility provides conversion for a
number of Switch features
To download the CCU package, select the CCU link on the CD that
accompanies your Switch 5500. Alternatively, the CCU download and
further information is available at:
http://www.3com.com/switchmigration/
DUA1715-0AAA02.book Page 49 Wednesday, March 23, 2005 11:17 AM
CHAPTER 3: SETTING UP FOR MANAGEMENT
DUA1715-0AAA02.book Page 50 Wednesday, March 23, 2005 11:17 AM
CREATING AN XRN STACKING
FABRIC
This chapter contains the information you need to create an XRN
Stacking Fabric. It covers the following topics:
■
How To Interconnect Units
■
Guidelines For Interconnecting Units
■
Unit Numbering within the Fabric
The procedure for creating a Fabric with the Switch 5500-SI units is the
same procedure as that for creating a Fabric with the Switch 5500-EI
units.
How To
Interconnect Units
Up to eight 3Com Switch 5500 units can be interconnected to create an
XRN Stacking Fabric and then treated as a single manageable unit with
one IP address.
You can interconnect your Switches to create an XRN Fabric using a
standard 1000 Mbps Ethernet connection. Table 14 lists the different
variants of the Switch 5500 family, how they physically interconnect and
the level of XRN support offered by the Fabric.
It is not possible to create a Fabric by interconnecting a 3Com Switch
5500 with any other 3Com device or mix Enhanced Image (EI) Switch
5500 units with Standard Image (SI) units.
This section assumes you have either set up your units for management
as detailed in Chapter 3 “Setting Up for Management”or that you are
using a console cable connected to the console port to set up and
allocate IP addresses and so on.
3Com recommends that you do not physically connect the cables on your
Fabric ports until you have carried out the initial configuration of the
Fabric ports as detailed below.
DUA1715-0AAA02.book Page 57 Wednesday, March 23, 2005 11:17 AM
CHAPTER 4: CREATING AN XRN STACKING FABRIC
Table 14 SuperStack 4 Switch 5500 Support for XRN Distributed Fabric
1 Ensure that the Switch units that you wish to interconnect have the latest
software agent installed. You can use the display version
command to check this.
2 Enable the ‘up port’ and the ‘down port’ on each Switch (see Table 14) to
operate in Fabric mode using the following CLI command. From the
System View enter fabric-port gigabitethernet 1/0/51
enable, for example.
As with all Switch 5500 CLI commands, the format for entering a
command that is port specific is x/y/z, where x = unit number, y = module
number (in the case of the Switch 5500 this will always be 0), z = port
number.
3 Connect the Fabric-enabled ‘up’ port on one Switch 5500 unit to the
Fabric-enabled ‘down’ port on another Switch 5500 unit using the
appropriate connection method for your Switch as detailed in Table 14.
4 To create a fully resilient Fabric: enable the spare Fabric ports on the
top-most and bottom-most units in the Fabric as described in the
previous steps. Then insert a cable into these two Fabric ports to create a
link between the top-most and bottom-most units in the Fabric, as shown
in Figure 17 on page 60.
This ensures that in the event of a unit failure within the Fabric, the Fabric
will continue working and no “Fabric split” will occur.
5 Save all configuration settings. From the User View, enter the save
command to save the configuration to your Switch.
Switch
Port used
XRN support
Switch 5500-SI 28-Port
(3C17151-91)
Ports 27 (up port) and 28
(down port) using a
1000 Mbps SFP transceiver
Only supports DDM*
* Distributed Device Management
Switch 5500-SI 52-Port
(3C17152-91)
Ports 51 (up port) and 52
(down port) using a
1000 Mbps SFP transceiver
Only supports DDM*
Switch 5500-EI 28-Port
(3C17161-91)
Ports 27 (up port) and 28
(down port) using a
1000 Mbps SFP transceiver
Full XRN functionality
Switch 5500-EI 52-Port
(3C17162-91)
Ports 51 (up port) and 52
(down port) using a
1000 Mbps SFP transceiver
Full XRN functionality
DUA1715-0AAA02.book Page 58 Wednesday, March 23, 2005 11:17 AM
Guidelines For Interconnecting Units
59
Guidelines For
Interconnecting
Units
This section offers some guidelines for creating a Fabric. Using these
guidelines will help prevent problems arising when setting up your Fabric.
■
The maximum number of Switch units that can be interconnected is
eight.
■
It is not possible to create a fabric by interconnecting a 3Com Switch
5500 with any other 3Com device (such as 5500G Switch units) or mix
Enhanced Image (EI) Switch 5500 units with Standard Image (SI) units.
■
3Com strongly recommends that you upgrade all Switches to be
interconnected to the latest software agent.
■
3Com recommends that you remove the configuration file from a
Switch unit that has previously been used elsewhere in your network
before you interconnect to an existing unit. If you do not do this,
problems may be caused by conflicting Switch configurations. Use the
dir command from the User View to display the configuration files
stored on the Switch and locate the [filename].cfg file. Do NOT
under any circumstances remove the 3comoscfg.def file (this is the
default configuration file).
■
When a port is operating in XRN Fabric mode it will no longer be
configurable in the normal way, that is, you cannot control port
features such as auto-negotiation, VLANs, static addresses, STP,
Aggregated Links, Resilient Links, and so on. However, it is possible to
specify the Fabric VLAN.
For a detailed description of how XRN Technology operates and
implementation guidelines, please refer to the Configuration Guide on
the CD-ROM that accompanies your Switch.
DUA1715-0AAA02.book Page 59 Wednesday, March 23, 2005 11:17 AM
CHAPTER 4: CREATING AN XRN STACKING FABRIC
Unit Numbering
within the Fabric
When a Fabric is created using the Switch 5500 the unit numbering can
be determined in two ways.
■
You can manually assign unit IDs 1 to 8 to specific units using the
change[self-unit, unit-id] to [1-8,
auto-numbering] command from the System View. If you
manually assign unit IDs to a Switch via the change command the IDs
will be retained after a power cycle.
If you add a unit to a Fabric that has previously been manually
configured with a unit ID and this conflicts with an ID already within
the Fabric, then the Switch with the lowest MAC address assumes the
ID in question and the other unit will automatically renumber.
3Com recommends that you manually assign the unit IDs within the
Fabric if you wish to have predictability of knowing which units have
which IDs at all times.
■
Fabric topology is ‘discovered’ and the units auto-number their IDs.
Adding and removing units from the Fabric does not cause any
renumbering to occur and the Fabric will continue to work normally.
Renumbering only occurs when the Fabric is next power cycled if the
units are configured to auto-number.
The unit LEDs will display the unit number in the Fabric, from 1 to 8.
Figure 17 Resilient Fabric example (using 4 units)
If you are having problems, refer to “Solving Fabric Formation Problems”
on page 66.
DUA1715-0AAA02.book Page 60 Wednesday, March 23, 2005 11:17 AM
This chapter helps you to diagnose and solve problems you may have
with the operation of your Switch. There is also an explanation of IP
addressing and upgrading software.
The topics covered are:
■
Solving Problems Indicated by LEDs
■
Solving Hardware Problems
■
Solving Communication Problems
■
Solving Fabric Formation Problems
If you experience a problem that is not listed here, it may be included in
the Support section of the SuperStack 4 Switch 5500 Command
Reference Guide on the CD-ROM that accompanies your Switch.
For Technical Support information, see Appendix D.
DUA1715-0AAA02.book Page 61 Wednesday, March 23, 2005 11:17 AM
CHAPTER 5: PROBLEM SOLVING
Solving Problems
Indicated by LEDs
If the LEDs on the Switch indicate a problem, refer to the list of suggested
solutions below.
The PWR LED does not light
Check that the power cable is firmly connected to the Switch and to the
supply outlet. If the connection is secure and there is still no power, you
may have a faulty power cord or an internal fault. Firstly, check the power
cord by:
■
testing it in another device.
■
connecting a working power cord to the ‘problem’ device then
contact your supplier for advice.
On powering-up, the PWR LED lights Red
The Switch unit has failed its Power On Self Test (POST) because of an
internal problem. The fault type will be indicated on the unit LEDs.
Contact your supplier for advice.
On powering-up, the PWR LED is flashing yellow
A port has failed and has been automatically disabled. You can verify this
by checking that the Port LED is quickly flashing Yellow. If a port fails, the
Switch passes its Power On Self Test and continues to operate normally.
A Port LED is flashing yellow
The port has failed and has been automatically disabled. The Switch
passes its Power On Self Test and continues to operate normally, even if
one or more ports are disabled.
A link is connected and yet the Port LED does not light
Check that:
■
The Switch and the device at the other end of the link (or cable) are
connected securely.
■
The devices at both ends of the link are powered-up
■
The quality of cable is satisfactory
■
Auto-negotiation settings are the same at both ends.
DUA1715-0AAA02.book Page 62 Wednesday, March 23, 2005 11:17 AM
Solving Hardware Problems
63
Auto-negotiation problems will occur with 10BASE-T or 100BASE-T
where auto-negotiation is disabled and incorrect cables are being used
(cross-over or straight)
Auto-negotiation problems will occur with fiber if:
■
The Receiver (RX) and Transceiver (TX) cable connectors are
swapped
■
Fibers are broken
■
Auto-negotiation differs at either end (a link appears at the ‘fixed’
end and not at the auto-negotiation end)
Solving Hardware
Problems
In the rare event of your Switch unit experiencing a hardware failure,
refer to the list of suggested solutions below.
A fan failure warning message is received
Your Switch has a fan monitoring system that will generate fan failure
warning messages. Fan failure could potentially reduce the lifetime of the
Switch. The monitoring system polls the fan status at periodic intervals
while the unit is powered up.
If one fan has failed in the Switch, a warning message will be generated
in the following ways:
■
Unit LED — the seven segment display will show a green flashing ‘f’.
■
RMON Trap — if configured, an RMON trap is generated and sent to
the management workstation.
■
Command Line Interface — an indication of a general hardware
failure is provided through the Top level menu displayed when logging
on to the CLI. For more detailed information about the failure select
the display logbuffer command.
■
Web interface — an indication of fan failure is provided through the
Device Summary table for the specific unit. In addition all Summary
tables turn red to indicate the fan failure.
If a fan failure warning message is generated:
1 Power off the unit.
2 Check that the air vents are not obstructed.
DUA1715-0AAA02.book Page 63 Wednesday, March 23, 2005 11:17 AM
CHAPTER 5: PROBLEM SOLVING
3 Power cycle the unit. To do this, remove and reconnect the AC mains
supply. If the unit has no AC main supply, remove and reconnect the DC
RPS supply.
4 If another fan failure warning message is generated via the Command
Line Interface or the Web interface, return the unit to 3Com.
Unit fails, no SNMP fan failure message is received
1 Power cycle the unit. To do this, remove and reconnect the AC mains
supply. If the unit has no AC mains supply, remove and reconnect the DC
RPS supply.
2 Check the command line interface (display logbuffer command)
to determine whether a thermal shutdown has occurred.
3 If no, return the unit:
If yes, check that:
■
The air vents are not obstructed.
■
The ambient temperatures and environmental conditions meet those
specified in Appendix C.
4 Power cycle the unit. If a further thermal shutdown occurs, and all
environmental conditions are satisfactory, return the unit to 3Com.
Error message indicating that the SFP transceiver is invalid
The Switch has identified that the SFP does not meet the minimum
requirements for the Switch and has disabled the port. To correct this
problem, completely remove the SFP and replace it with a 3Com
approved SFP. See “Approved SFP Transceivers” on page 31.
Error message indicating that the SFP transceiver is faulty
To correct this problem, completely remove the SFP and then reinsert it.
Alternatively, insert another identical SFP. If the problem persists, contact
3Com Technical Support.
Solving
Communication
Problems
If you experience communication problems with the Switch, ensure that:
■
The Switch IP address and Management VLAN ID has been
configured.
DUA1715-0AAA02.book Page 64 Wednesday, March 23, 2005 11:17 AM
Solving Communication Problems
65
■
If the Switch is separated from your management application by a
router, ensure that the default gateway IP address within the Switch is
the same as the IP address of the router.
■
The Switch’s IP address has been entered correctly in your network
management application (such as 3Com Network Director).
The following is a brief overview of IP addressing, and how to obtain a
registered IP address.
IP Addressing
To be managed correctly, each device on your network (for example a
Switch or Hub) must have a unique IP address. IP addresses have the
format n.n.n.n where n is a decimal number between 0 and 255. An
example IP address is 192.168.100.8.
The IP address is split into two parts:
■
The first part (‘192.168.100’ in the example) identifies the network on
which the device resides
■
The second part (‘.8’ in the example) identifies the device within the
network
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you
access the Internet, you must apply for a registered IP address.
How do you obtain a registered IP Address?
The IP registration system ensures that every IP address used is unique; if
you do not have a registered IP address, you may be using an identical
address to someone else and your network will not operate correctly.
InterNIC Registration Services is the organization responsible for
supplying registered IP addresses. The following contact information is
correct at time of publication:
World Wide Web site: http://www.internic.net
If your IP network is internal to your organization only, that is, you do not
access the Internet, you may use any arbitrary IP address as long as it is
not being used by another device on your network. 3Com suggests you
DUA1715-0AAA02.book Page 65 Wednesday, March 23, 2005 11:17 AM
CHAPTER 5: PROBLEM SOLVING
use addresses in the range 192.168.0.0 to 192.168.255.255 with a
subnet mask of 255.255.255.0.
These suggested IP addresses are part of a group of IP addresses that
have been set aside specially for use ‘in house’ only.
Solving Fabric
Formation
Problems
If you are having problems with correctly forming a fabric, first ensure
that Spanning Tree is enabled. If it is enabled, do the following:
1 Power off all units in the fabric.
2 Check all the cable connections in the fabric.
3 Check the ports have been enabled as fabric ports.
4 Power on all units in the fabric.
DUA1715-0AAA02.book Page 66 Wednesday, March 23, 2005 11:17 AM
This chapter describes how to upgrade software to your Switch 5500. It
covers the following topics:
■
Upgrading from the Command Line Interface
■
Upgrading from the Bootrom Interface
■
Bootrom Upgrade
DUA1715-0AAA02.book Page 67 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
Upgrading from the
Command Line
Interface
This section describes how to upgrade files to your Switch from the
Command Line Interface (CLI).
Introduction
Before upgrading the software to your Switch from the CLI, it is
important to check the contents of the flash to ensure that there is
enough space to download the new files.
The flash space needed for the new files is approximately 5.5 MB.
1 To check the contents of the flash, logon to your Switch either via a telnet
connection or directly via the console to display the User View in the CLI
and enter the following:
dir unit1>flash:
A file list similar to the following is displayed:
Directory of unit1>flash:/
15367 KB total (10215 KB free)
2 You can check the contents of the flash for the remaining units in the
fabric by entering:
dir unit2>flash:
dir unit3>flash:
dir unit4>flash:
dir unit5>flash:
dir unit6>flash:
dir unit7>flash:
The file list should contain one of each file type (.zip, .def, .cfg
and .app).
3 Any additional files should be considered for deletion to allow maximum
space for downloading the new files. To delete a file from the list enter:
delete/unreserved unit1>flash:/filename
0 -rw-
714784
Apr 02 2005 01:36:16
s4h03_01_00.zip
1
-rw-
11043
Apr 02 2005 01:37:17
3ComOScfg.def
2
-rw-
11427
Apr 02 2005 00:01:01
3ComOScfg.cfg
3
-rw-
4529259
Apr 02 2005 01:39:57
s4b03_01_00s168.app
DUA1715-0AAA02.book Page 68 Wednesday, March 23, 2005 11:17 AM
Upgrading from the Command Line Interface
69
To delete files from the list for the remaining units in a fabric, replace
unit1 with unit2 (on the next line) and so on for each Switch in the
fabric.
4 The /unreserved option will cause the file to be deleted from both the
flash and the recycle-bin. To check that deleted files have been removed
from the recycle-bin enter the following:
reset recycle-bin unit1>flash:/
If the recycle-bin is empty the following is displayed:
% File can’t be found “unitN>flash:/”
To check that deleted files have been removed from the recycle-bin for
the remaining units in a fabric, replace unit1 with unit2 and so on for
each Switch in the fabric.
The following steps enable you to backup each Switch in the fabric:
1 To back up the default configuration file on each Switch in the fabric,
enter:
copy unit1>flash:/3ComOScfg.def
unit1>flash:/030100cfg.def
Replace unit1 with unit2 and so on for each Switch in the fabric.
2 To back up the active configuration file on each Switch in the fabric,
enter:
copy unit1>flash:/3ComOScfg.cfg
unit1>flash:/030100cfg.cfg
Replace unit1 with unit2 and so on for each Switch in the fabric.
3 To back up the Web user interface file on each Switch in the fabric, enter:
copy unit1>flash:/s4h03_01_00.zip
unit1>flash:/030100http.zip
Replace unit1 with unit2 and so on for each Switch in the fabric.
TFTP
To upgrade software to your Switch via TFTP do the following:
1 To download the application file, enter:
tftp aaa.aaa.aaa.aaa get s4a03_01_00s168.app
DUA1715-0AAA02.book Page 69 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
(where aaa.aaa.aaa.aaa is the IP address of the TFTP server)
s4a indicates the Switch filename, see Table 15 for further details:
Table 15 Switch 5500 Filenames
2 To download the Web user interface file, enter:
tftp aaa.aaa.aaa.aaa get http.zip
3 To download the default configuration file, enter:
tftp aaa.aaa.aaa.aaa get 3ComOScfg.def
4 To download the bootrom file, enter:
tftp aaa.aaa.aaa.aaa get s4e002_012_000.btm
The bootrom firmware may not require upgrading for every software
upgrade, therefore there may not be a new bootrom (.btm) file to
download.
File Distribution
The following commands enable you to distribute your downloaded files
to the remaining Switches in the fabric:
1 To copy the new software file to each Switch in the fabric, enter:
copy unit1>flash:/s4a03_01_00s168.app unit2>flash:/
Replace unit2 with unit3 and so on for each Switch in the fabric.
2 To copy the new default configuration file to each Switch in the fabric,
enter:
copy unit1>flash:/3ComOScfg.def unit2>flash:/
Replace unit2 with unit3 and so on for each Switch in the fabric.
3 To copy the new Web user interface file to each Switch in the fabric,
enter:
copy unit1>flash:/http.zip unit2>flash:/
Replace unit2 with unit3 and so on for each Switch in the fabric.
4 To copy the new Bootrom firmware file to each Switch in the fabric,
enter:
Filename Prefix
Switch
s4a
SuperStack 4 Switch 5500-SI software
s4b
SuperStack 4 Switch 5500-EI software
s4e
SuperStack 4 Switch 5500 bootrom software
DUA1715-0AAA02.book Page 70 Wednesday, March 23, 2005 11:17 AM
Upgrading from the Command Line Interface
71
copy unit1>flash:/s4e002_012_000.btm unit2>flash:/
Replace unit2 with unit3 and so on for each Switch in the fabric.
Command Line Interface Switch Setup
1 To set the Switch to boot from the new software you have downloaded,
enter the following:
boot boot-loader unit1>flash:/s4a03_01_00s168.app
To set the remaining Switches in the fabric to boot from the new
software, replace unit1 with unit2 and so on for each Switch in the
fabric.
2 To set the Switch to load the new bootrom firmware, enter:
boot bootrom unit1>flash:/s4e002_012_000.btm
To set the remaining Switches in the fabric to load the new bootrom
firmware, replace unit1 with unit2 and so on for each Switch in the
fabric.
3 You will now need to reboot the fabric for the changes to take effect. The
Switch will upgrade the bootrom firmware and boot from the specified
software .app file.
The files that you have saved in the backup phase should be deleted once
the upgrade has completed successfully.
FTP (via a network
port)
To upgrade software to your Switch via FTP do the following:
1 Enter the following command from User View:
ftp aaa.aaa.aaa.aaa
(where aaa.aaa.aaa.aaa is the IP address of the FTP server)
If the FTP server has been successfully located, the following information
is displayed:
Trying...
Press CTRL+K to abort
Connected
DUA1715-0AAA02.book Page 71 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
Information on your FTP server is displayed, logon with your username
and password.
2 To download the configuration file, enter:
get 3ComOScfg.def
The following information is displayed if the download has been
successful:
200 PORT command successful.
150 Opening ASCII mode data connection for
vrpcfg.def(10986 bytes).......226 Transfer complete.
FTP: 10986 byte(s) received in 8.046 second(s) 1000.00
byte(s)/sec.
3 Enter quit to exit.
XModem (via the
console cable)
To upgrade software to your Switch via XModem do the following:
1 From the User View, enter:
xmodem get unit1>flash:/3ComOScfg.def
The following information is displayed:
**** WARNING ****
xmodem is a slow transfer protocol limited to the
current speed
settings of the auxiliary ports.
During the course of the download no exec input/output
will be available!
Proceed?[Y/N]y
Destination filename [unit1>flash:/vrpcfg.def]?
Before pressing ENTER you must choose ‘YES’ or
‘NO’[Y/N]:
2 Enter y to display the following message:
Download with XMODEM protocol...
...C..
DUA1715-0AAA02.book Page 72 Wednesday, March 23, 2005 11:17 AM
Upgrading from the Bootrom Interface
73
3 As the file is downloading, start the XModem send file process with
terminal emulation software, such as Microsoft Hyperterminal.
When the file download is complete the message Download
successful! is displayed.
4 Repeat steps 1 to 3 for each of the remaining files.
Upgrading from the
Bootrom Interface
This section describes how to upgrade your Switch from the Bootrom
Interface.
Introduction
When the Switch is running the initial boot phase via the console, the
following prompt is displayed with a five second countdown timer:
Press CTRL-B to enter Boot Menu... 4
followed by a password prompt:
password:
1 Select Enter (the default is no password) to display the following boot
menu:
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
2 Enter the appropriate menu number to select a specific option.
Before upgrading the software to your Switch from the Bootrom
Interface it is important to check the contents of the flash to ensure that
there is enough space to download the new files.
DUA1715-0AAA02.book Page 73 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
3 Select option 3 from the Boot Menu. A file list similar to the following is
displayed:
Boot menu choice: 3
Free Space: 10460160 bytes
The current application file is s4b03_01_00s168.app
This option displays all the files in flash and also indicates the file that the
Switch is currently set to boot from (marked with an asterix).
The files which are required by the Switch are:
s4h03_01_00.zip
3ComOScfg.def
3ComOScfg.cfg
s4b03_01_00s168.app
The s4b03_01_00s168.app file is the boot software. The name of this
file will vary depending on the Switch type and the release version.
Any additional files should be considered for deletion to allow maximum
space for downloading the new files.
4 To delete a file from the list select option 4 from the Boot Menu and
select the file number you wish to delete.
TFTP
To upgrade software to your Switch via TFTP, do the following:
1 From the Boot Menu, select option 1 (Download application file to flash)
to display the following:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
File Number
File Size(bytes) File Name
====================================================
1
714784
s4h03_01_00.zip
2
164
private-data.txt
3
11043
3ComOScfg.def
4
4
snmpboots
5*
4529259
s4b03_01_00s168.app
6
11343
3ComOScfg.cfg
DUA1715-0AAA02.book Page 74 Wednesday, March 23, 2005 11:17 AM
Upgrading from the Bootrom Interface
75
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 1 to display the following:
Load File name:
Switch IP address:
Server IP address:
3 Enter the file name, Switch IP address and Server IP address to display the
following:
Are you sure to download file to flash? Yes or No(Y/N)
4 Enter y and the following information is displayed to indicate the file is
downloading:
Attached TCP/IP Interface to netdrv0
Attaching network interface lo0...done
Loading.....done
Free flash Space: 10456064 bytes
Writing flash....done!
5 Repeat steps 1 to 4 for each of the remaining files.
FTP
To upgrade software to your Switch via FTP, do the following:
1 From the Boot Menu, select option 1 (Download application file to flash)
to display the following:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 2 to display the following:
Load File name:
Switch IP address:
Server IP address:
FTP User Name:
FTP User Password:
3 Enter the file name, Switch IP address, Server IP address and FTP user
name and password to display the following:
Are you sure to download file to flash? Yes or No(Y/N)
DUA1715-0AAA02.book Page 75 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
4 Enter y and the following information is displayed to indicate the file is
downloading:
Loading.....done
Free flash Space: 10456064 bytes
Writing flash....done!
5 Repeat steps 1 to 4 for each of the remaining files.
XModem
To upgrade software to your Switch via XModem, do the following:
1 From the Boot Menu, select option 1 (Download application file to flash)
to display the following:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 3 to display the following:
Please select your download baudrate:
1. 9600
2.*19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice(0-5):
3 Select option 2 to set the baudrate to 19200.
You will also need to change the baudrate on Hyperterminal to 19200
bps and select XModem protocol.
4 Press Enter to start the download. The following information is displayed:
Now please start transfer file with XMODEM protocol
If you want to exit, Press
Loading...CCCCCCCCCCCCCCCCCCCCCCCCCCCCC
5 As the file is downloading, start the XModem send file process with
terminal emulation software, such as Microsoft Hyperterminal.
When the download is complete, the following information is displayed:
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCdone!
DUA1715-0AAA02.book Page 76 Wednesday, March 23, 2005 11:17 AM
6 Repeat steps 1 to 5 for each of the remaining files.
Bootrom Upgrade
This section describes how to indicate which file the Switch is to boot
from once the software has been loaded.
1 From the Boot menu, select option 2 to display a file list similar to the
following:
Boot menu choice: 2
Free Space: 10460160 bytes
The current application file is s4b03_01_00s168.app
Please input the file number to boot:
2 Select the required file number to boot (in the example it is 5).
Bootrom Upgrade via
TFTP
To upgrade the bootrom firmware from the Boot menu via TFTP do the
following:
1 From the Boot menu, select option 6 to display the bootrom upgrade
menu as shown:
Bootrom update menu:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 1 to display the following:
Load File name:
Switch IP address:
Server IP address:
File Number
File Size(bytes) File Name
====================================================
1
714784
s4h03_01_00.zip
2
164
private-data.txt
3
11043
3ComOScfg.def
4
4
snmpboots
5*
4529259
s4b03_01_00s168.app
6
11343
3ComOScfg.cfg
DUA1715-0AAA02.book Page 77 Wednesday, March 23, 2005 11:17 AM
CHAPTER 6: UPGRADING SOFTWARE
3 Enter the file name, Switch IP address and Server IP address to display the
following:
Are you sure to update your bootrom? Yes or No(Y/N)
4 Enter y and the following information is displayed to indicate the file is
downloading:
Attached TCP/IP interface to netdrv0
Attaching network interface Io0...done
Loading.................................
...............done
Bootrom updating............done!
Bootrom Upgrade via
FTP
To upgrade the bootrom firmware from the Boot menu via FTP do the
following:
1 From the Boot menu, select option 6 to display the bootrom upgrade
menu as shown:
Bootrom update menu:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 2 to display the following:
Load File name:
Switch IP address:
Server IP address:
FTP User Name:
FTP User Password:
3 Enter the file name, Switch IP address, Server IP address, FTP user name
and password to display the following:
Are you sure to update your bootrom? Yes or No(Y/N)
4 Enter y and the following information is displayed to indicate the file is
downloading:
Attached TCP/IP interface to netdrv0
Attaching network interface Io0...done
Loading.................................
...............done
Bootrom updating............done!
DUA1715-0AAA02.book Page 78 Wednesday, March 23, 2005 11:17 AM
Bootrom Upgrade via
XModem
To upgrade the bootrom firmware from the Boot menu via XModem do
the following:
1 From the Boot Menu, select option 6 to display the following:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return to boot menu
Enter your choice(0-3):
2 Select option 3 to display the following:
Please select your download baudrate:
1. 9600
2.*19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice(0-5):
3 Select option 2 to set the baudrate to 19200.
You will also need to change the baudrate on Hyperterminal to 19200
bps and select XModem protocol.
4 Press Enter to start the download. The following information is displayed:
Now please start transfer file with XMODEM protocol
If you want to exit, Press
Loading
...CCCCCCCCCCCCCCCCCCCCCCCCCCCCC
5 As the file is downloading, start the XModem send file process with
terminal emulation software, such as Microsoft Hyperterminal.
When the download is complete, the following information is displayed:
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCdone!
Bootrom updating.........done!
DUA1715-0AAA02.book Page 79 Wednesday, March 23, 2005 11:17 AM
You must read the following safety information before carrying out any
installation or removal of components, or any maintenance procedures
on the Switch 5500.
WARNING: Warnings contain directions that you must follow for your
personal safety. Follow all directions carefully.
You must read the following safety information carefully before you
install or remove the unit.
AVERTISSEMENT: Les avertissements présentent des consignes que vous
devez respecter pour garantir votre sécurité personnelle. Vous devez
respecter attentivement toutes les consignes.
Nous vous demandons de lire attentivement les consignes suivantes de
sécurité avant d’installer ou de retirer l’appareil.
VORSICHT: Warnhinweise enthalten Anweisungen, die Sie zu Ihrer
eigenen Sicherheit befolgen müssen. Alle Anweisungen sind sorgfältig zu
befolgen.
Sie müssen die folgenden Sicherheitsinformationen’ sorgfältig
durchlesen, bevor Sie das Gerät installieren oder ausbauen.
ADVERTENCIA: Las advertencias contienen indicaciones que debe
respetar por su seguridad personal.
Siga las indicaciones con cuidado. Antes de instalar o extraer la unidad,
debe leer detenidamente la siguiente información de seguridad.
AVVERTENZA: le avvertenze contengono istruzioni indispensabili per
assicurare la sicurezza personale. Seguire attentamente tutte le
indicazioni fornite. Prima di installare o rimuovere l'unità, leggere
attentamente le seguenti informazioni di sicurezza.
OSTRZEŻENIE: Ostrzeżenia zawierają wskazówki, których należy
przestrzegać dla własnego bezpieczeństwa. Należy uważnie
przestrzegać wszystkich wskazówek. Przed instalacją lub demontażem
DUA1715-0AAA02.book Page 81 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
urządzenia należy uważnie przeczytać poniższe informacje o
bezpieczeństwie.
Power Cord Set — Japan
Important Safety Information
WARNING: Installation and removal of the unit must be carried out by
qualified personnel only.
WARNING: If installing the Switch 5500 together (one on top of the
other) with SuperStack II or SuperStack 3 units that are shallower than
the 5500, the Switch 5500 unit must be installed below the shallower
units.
WARNING: The unit must be earthed (grounded) or must be connected
to an earthed power supply to ensure compliance with safety standards.
WARNING: Power Cord Set:
This must be approved for the country where it is used:
U.S.A. and
Canada
■
The cord set must be UL-approved and CSA certified.
■
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
■
The cord set must have a rated current capacity of at least
10A.
■
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,
250V) configuration.
United
Kingdom only
■
The supply plug must comply with BS1363 (3-pin 13 amp)
and be fitted with a 5A fuse which complies with BS1362.
■
The mains cord must be or marked and
be of type H03VVF3GO.75 (minimum).
DUA1715-0AAA02.book Page 82 Wednesday, March 23, 2005 11:17 AM
Important Safety Information
83
WARNING: The appliance coupler (the connector to the unit and not the
wall plug) must have a configuration for mating with an EN60320/IEC320
appliance inlet.
WARNING: The socket outlet must be near to the unit and easily
accessible.
WARNING: This unit operates under SELV (Safety Extra Low Voltage)
conditions according to IEC 60950. The conditions are only maintained if
the equipment to which it is connected also operates under SELV
conditions.
WARNING: France and Peru only:
This unit cannot be powered from IT† supplies. If your supplies are of IT
type, this unit must be powered by 230V (2P+T) via an isolation
transformer ratio 1:1, with the secondary connection point labelled
Neutral, connected directly to earth (ground).
†Impédance à la terre.
WARNING: U.K. only:
If connecting a modem to the console port of the Switch 5500, only use a
modem which is suitable for connection to the telecommunications
system.
WARNING: RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot
be used as standard traditional telephone sockets, or to connect the unit to a
traditional PBX or public telephone network. Only connect RJ-45 data
connectors, network telephony systems, or network telephones to these
sockets.
Either shielded or unshielded data cables with shielded or unshielded
jacks can be connected to these data sockets.
WARNING: Fiber Optic ports – Optical Safety
Europe only:
■
The supply plug must comply with CEE 7/7 (“SCHUKO”).
■
The mains cord must be or marked and
be of type H03VVF3GO.75 (minimum).
Denmark
■
The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
Switzerland
■
The supply plug must comply with SEV/ASE 1011.
DUA1715-0AAA02.book Page 83 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
Never look at the transmit laser through a magnifying device while it is
powered on. Never look directly at the fiber TX port and fiber cable ends
when they are powered on.
WARNING: This device has more than one power input. Disconnect all
power inputs to power off this device.
WARNING: The installation of the Redundant Power Supply (RPS) should
only be carried out by properly trained and qualified personnel.
WARNING: These instructions must be read in conjunction with the RPS
flyer and the safety and installation instructions supplied with your RPS.
WARNING: When powering any Switch 5500 from an RPS, the unit must
be earthed (grounded). This can be achieved by either connecting the
power cord to the unit or by connecting the earth terminal on the rear of
the unit to a reliable electrical earth, or by connecting both. It must be
ensured that the earth connection is made before connecting the DC
supply from the RPS.
WARNING: Any RPS must be approved as an unearthed SELV output in
accordance with IEC 60950-1/UL 60950-1/EN 60950-1.
WARNING: The characteristics of the Switch 5500 DC supply input are
given in Appendix C on page 105.
WARNING: RPS Manufacturers recommendations must be followed
when connecting the cable to the RPS.
WARNING: Ensure that the circuit breaker in the RPS is in the open (off)
position when connecting the cable to the RPS.
WARNING: You must ensure that the positive terminal on the Switch is
connected to the positive (common) terminal of the RPS and that the
negative terminal on the Switch is connected to the negative (circuit
breaker) terminal of the RPS.
Class 1
LASER PRODUCT
DUA1715-0AAA02.book Page 84 Wednesday, March 23, 2005 11:17 AM
L’information de Sécurité Importante
85
WARNING: Ensure that the circuit breaker in the RPS is in the open (off)
position when connecting the RPS cable and connector to the Switch.
L’information de Sécurité Importante
AVERTISSEMENT: L'installation et la dépose de ce groupe doivent être
confiés à un personnel qualifié.
AVERTISSEMENT: Si vous entassez l'unité Switch avec les unités
SuperStack 4 Hub, l'unité Switch 5500 doit être installée en dessous des
unités Hub plus étroites.
AVERTISSEMENT: Vous devez mettre l’appareil à la terre (à la masse) ce
groupe.
AVERTISSEMENT: Brancher l’unité à une source de courant mise à la
terre pour assurer la conformité aux normes de sécurité.
AVERTISSEMENT: Cordon électrique:
Il doit être agréé ans le pays d'utilisation:
Etats-Unis et
Canada
■
Le cordon doit avoir reçu l'homologation des UL et un
certificat de la CSA
■
Le cordon souple doit respecter, à titre minimum, les
spécifications suivantes :
■
calibre 18 AWG
■
type SV ou SJ
■
à 3 conducteurs
■
Le cordon doit être en mesure d'acheminer un courant
nominal d'au moins 10 A
■
La prise femelle de branchement doit être du type à mise à la
terre (mise à la masse) et respecter la configuration NEMA
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V)
Danemark
■
La prise mâle d'alimentation doit respecter la section 107-2
D1 de la norme DK2 1a ou DK2 5a
Europe
■
La prise secteur doit être conforme aux normes CEE 7/7
(“SCHKO”)
■
LE cordon secteur doit porter la mention ou
et doit être de type HO3VVF3GO.75 (minimum).
Suisse
■
La prise mâle d'alimentation doit respecter la norme SEV/ASE
1011
DUA1715-0AAA02.book Page 85 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
AVERTISSEMENT: Le coupleur d'appareil (le connecteur du groupe et
non pas la prise murale) doit respecter une configuration qui permet un
branchement sur une entrée d'appareil EN60320/CEI 320.
AVERTISSEMENT: La prise secteur doit se trouver à proximité de
l’appareil et son accès doit être facile.
AVERTISSEMENT: L’appareil fonctionne à une tension extrêmement
basse de sécurité qui est conforme à la norme CEI 60950. Ces conditions
ne sont maintenues que si l'équipement auquel il est raccordé fonctionne
dans les mêmes conditions.
AVERTISSEMENT: France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la
terre. Si vos alimentations sont du type impédance à la terre, ce groupe
doit être alimenté par une tension de 230 V (2 P+T) par le biais d'un
transformateur d'isolement à rapport 1:1, avec un point secondaire de
connexion portant l'appellation Neutre et avec raccordement direct à la
terre (masse).
AVERTISSEMENT: Points d’accès RJ-45. Ceux-ci sont protégés par des
prises de données. Ils ne peuvent pas être utilisés comme prises de
téléphone conventionnelles standard, ni pour la connection de l’unité à
un réseau téléphonique central privé ou public. Raccorder seulement
connecteurs de données RJ-45, systèmes de réseaux de téléphonie ou
téléphones de réseaux à ces prises.
Il est possible de raccorder des câbles protégés ou non protégés avec des
jacks protégés ou non protégés à ces prises de données.
AVERTISSEMENT: Ports pour fibres optiques – sécurité sur le plan
optique.
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais
directement le port à fibres optiques et les embouts de câbles à fibres
optiques tant qu'ils sont sous tension.
Dispositif Laser
de Classe 1
DUA1715-0AAA02.book Page 86 Wednesday, March 23, 2005 11:17 AM
L’information de Sécurité Importante
87
AVERTISSEMENT: Ce périphérique comporte plusieurs entrées
d'alimentation. Déconnectez toutes les entrées d'alimentation afin de le
mettre hors tension.
AVERTISSEMENT: L'installation du RPS (Redundant Power Supply) ne
doit être confiée qu'à un personnel formé et qualifié.
AVERTISSEMENT: Ces instructions doivent être lues conjointement avec
les instructions d'installation et les consignes de sécurité qui
accompagnent le RPS.
AVERTISSEMENT: Lorsqu'un commutateur Switch 5500 est alimenté par
un module RPS, l'unité doit être mise à la terre. Pour cela, branchez le
cordon d'alimentation à l'unité ou branchez la borne de mise à la terre
située à l'arrière de l'unité à une prise de terre fiable, ou procédez aux
deux raccordements. Assurez-vous que l'unité est mise à la terre avant de
raccorder l'alimentation CC du RPS.
AVERTISSEMENT: Le RPS doit être approuvé en tant que sortie SELV non
reliée à la terre, conformément à la norme IEC 60950-1/UL 60950-1/EN
60950-1.
AVERTISSEMENT: Ces instructions doivent être lues conjointement avec
les caractéristiques de l'alimentation CC du Switch 5500 fournies en
annexe C, Spécifications techniques.
AVERTISSEMENT: Vous devez respecter les recommandations du
fabricant lors du branchement du câble au module RPS.
AVERTISSEMENT: Assurez-vous que le disjoncteur du RPS est ouvert (off)
lors du branchement du câble au RPS.
AVERTISSEMENT: Assurez-vous de brancher la borne positive du
commutateur à la borne positive (commune) du RPS, et la borne négative
du commutateur à la borne négative (disjoncteur) du RPS.
AVERTISSEMENT: Assurez-vous que le disjoncteur du RPS est ouvert (off)
lors du branchement du câble et du connecteur du RPS au commutateur
3Com.
DUA1715-0AAA02.book Page 87 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
Wichtige Sicherheitsinformationen
VORSICHT: Alle Verfahren die in dieser Anleitung beschrieben werden
gelten für alle Modelle, sofern nicht anders angegeben. Wo eine
Vorgehensweise für die Schalter 5500-SI 24 und Schalter 5500-SI 52 gilt
wird nur der Begriff Schalter verwendet.
Diese Anleitung ist für Netzwerkadministratoren vorgesehen, die für die
Installation und das Einstellen von Netzwerkkomponenten verantwortlich
sind; Erfahrung im Umgang mit LANs (Local Area Networks) wird
VORSICHT: Die Installation und der Ausbau des Geräts darf nur durch
Fachpersonal erfolgen.
VORSICHT: Wenn die Switch 5500 Einheit in einer Stapel mit anderen
SuperStack 4 Hub Einheiten eingebaut werden soll, muß die Switch 5500
Einheit unter die schmaleren Hub Einheiten eingebaut werden.
VORSICHT: Das Gerät muß geerdet sein.
VORSICHT: Das Gerät muß an eine geerdete Steckdose angeschlossen
werden, die europäischen Sicherheitsnormen erfüllt.
VORSICHT: Der Anschlußkabelsatz muß mit den Bestimmungen des
Landes übereinstimmen, in dem er verwendet werden soll.
VORSICHT: Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß eine passende Konfiguration für einen
Geräteeingang gemäß EN60320/IEC320 haben.
VORSICHT: Die Netzsteckdose muß in der Nähe des Geräts und leicht
zugänglich sein. Die Stromversorgung des Geräts kann nur durch
Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen
werden.
VORSICHT: Europe
■
Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung)
sein und die Aufschrift oder tragen.
■
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
DUA1715-0AAA02.book Page 88 Wednesday, March 23, 2005 11:17 AM
VORSICHT: Der Betrieb dieses Geräts erfolgt unter den
SELV-Bedingungen (Sicherheitskleinstspannung) gemäß IEC 60950. Diese
Bedingungen sind nur gegeben, wenn auch die an das Gerät
angeschlossenen Geräte unter SELV-Bedingungen betrieben werden.
VORSICHT: RJ-45-Porte. Diese Porte sind geschützte Datensteckdosen.
Sie dürfen weder wie normale traditionelle Telefonsteckdosen noch für
die Verbindung der Einheit mit einem traditionellem privatem oder
öffentlichem Telefonnetzwerk gebraucht werden. Nur
RJ-45-Datenanscluße, Telefonnetzsysteme or Netztelefone an diese
Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen an diese
Datensteckdosen angeschlossen werden.
VORSICHT: Faseroptikanschlüsse – Optische Sicherheit
.
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet
ist. Niemals direkt auf die Faseransnchlüsse und auf die Faserkabelenden
schauen, während diese eingeschaltet sind.
VORSICHT: Dieses Gerät besitzt mehrere Eingänge zur Stromversorgung.
Trennen Sie das Gerät zum Ausschalten von allen Stromquellen.
VORSICHT: Die RPS (Redundant Power Supply, redundante
Stromversorgung) darf nur von entsprechend geschultem und
qualifiziertem Fachpersonal installiert werden.
VORSICHT: Diese Anleitungen müssen im Zusammenhang mit den
Sicherheitshinweisen und Installationsanleitungen zu Ihrer RPS gelesen
werden.
VORSICHT: Bei der Stromversorgung eines Switch 5500 über eine RPS
muss das Gerät geerdet sein. Hierfür kann entweder das Netzkabel an
das Gerät angeschlossen werden oder die Erdungsklemme an der
Rückseite des Geräts mit einer zuverlässigen elektrischen Erdung
verbunden werden oder beides. Es ist sicherzustellen, dass die
Laser Gerät
der Klasse 1
DUA1715-0AAA02.book Page 89 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
Erdungsverbindung vor dem Anschließen der von der RPS bereitgestellten
Gleichstromversorgung hergestellt wird.
VORSICHT: Jede RPS muss als nicht geerdetes SELV-Ausgangsgerät
gemäß IEC 60950-1/UL 60950-1/EN 60950-1 zugelassen sein.
VORSICHT: Diese Anleitungen müssen im Zusammenhang mit den
Eigenschaften des Gleichstrom-Versorgungseingangs des Switch 5500
gelesen werden, die in Anhang C, "Technische Daten", aufgeführt sind.
VORSICHT: Beim Anschließen des Kabels an die RPS sind die
Empfehlungen des Herstellers zu beachten.
VORSICHT: Stellen Sie sicher, dass sich der Schutzschalter an der RPS
beim Anschließen des Kabels an die RPS in der geöffneten Stellung (Aus)
befindet.
VORSICHT: Stellen Sie auf jeden Fall sicher, dass die positive Klemme am
Switch an die positive (gemeinsame) Klemme der RPS und die negative
Klemme am Switch an die negative (gemeinsame) Klemme der RPS
angeschlossen wird.
VORSICHT: Stellen Sie sicher, dass sich der Schutzschalter an der RPS
beim Anschließen des RPS-Kabels und des Steckers des 3Com Switch in
der geöffneten Stellung (Aus) befindet.
Información de Seguridad Importante
ADVERTENCIA: La instalación o la extracción de la unidad sólo debe
llevarla a cabo personal cualificado.
ADVERTENCIA: Si instala el 5500 en una pila con unidades SuperStack II
o SuperStack 3 que son más estrechas que el 5500, la unidad 5500 debe
instalarse debajo de las unidades más estrechas.
ADVERTENCIA: La unidad debe tener toma de tierra (conectado a
tierra).
ADVERTENCIA: Conecte la unidad a una fuente de alimentación con
toma de tierra para garantizar el cumplimiento de las normas de
seguridad.
DUA1715-0AAA02.book Page 90 Wednesday, March 23, 2005 11:17 AM
Información de Seguridad Importante
91
ADVERTENCIA: Conjunto de cables eléctricos:
Debe estar homologado para el país donde se utilice:
ADVERTENCIA: El acoplador del equipo (el conector para la unidad y no
la toma de la pared) debe tener una configuración que se adapte a una
entrada del equipo EN60320/IEC320.
ADVERTENCIA: El enchufe debe estar cerca de la unidad y ser de fácil
acceso.
ADVERTENCIA: Esta unidad funciona en condiciones SELV (voltaje
extrabajo de seguridad) de conformidad con la norma IEC 60950. Las
condiciones sólo se mantienen si el equipo al que esté conectada la
unidad también funciona en condiciones SELV.
ADVERTENCIA: Sólo para Francia y Perú: esta unidad no puede recibir
corriente de fuentes IT†. Si las fuentes de suministro de corriente son de
tipo IT, esta unidad debe recibir 230 V (2P+T) a través de un
transformador aislador con relación 1:1, con el punto de conexión
EE.UU. y
Canadá
■
El conjunto de cables debe estar homologado por UL y
tener la certificación CSA.
■
La especificación mínima del cable flexible es: Nº 18 AWG
Tipo SV o SJ Tres conductores
■
El conjunto de cables debe tener una capacidad de
corriente nominal de al menos 10 A.
■
El enchufe de conexión debe ser de tipo de toma de tierra
con una configuración NEMA 5-15P (15 A, 125 V) o NEMA
6-15P (15 A, 250 V).
Sólo para el
Reino Unido
■
La toma de alimentación debe cumplir la norma BS1363 (3
patillas, 13 A) e instalarse con un fusible de 5 A que
cumpla BS1362.
■
El cable de alimentación de red debe tener la marca
o y ser de tipo H03VVF3GO.75
(mínimo).
Sólo para
Europa:
■
La toma de alimentación debe cumplir la norma CEE 7/7
("SCHUKO").
■
El cable de alimentación de red debe tener la marca
o y ser de tipo H03VVF3GO.75
(mínimo).
Dinamarca
■
La toma de alimentación debe cumplir la sección 107-2-D1
de la norma DK2-1a o DK2-5a
Suiza
■
La toma de alimentación debe cumplir la norma SEV/ASE
1011.
DUA1715-0AAA02.book Page 91 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
secundario etiquetado como neutro conectado directamente a tierra.
†Impédance à la terre.
ADVERTENCIA: Sólo para el Reino Unido: si conecta un módem al
puerto de consola del 5500, utilice sólo un módem que sea adecuado
para la conexión con el sistema de telecomunicaciones.
ADVERTENCIA: Puertos RJ-45. Son conectores de datos RJ-45 blindados.
No pueden utilizarse como tomas de teléfono tradicionales estándar ni
para conectar la unidad a una central de conmutación PBX tradicional ni
a una red telefónica pública. Conecte sólo conectores de datos RJ-45,
sistemas de telefonía de red local o teléfonos de red local a estas tomas.
Pueden conectarse cables de datos blindados o sin blindaje con clavijas
blindadas o sin blindaje a estos conectores de datos.
ADVERTENCIA: Puertos de fibra óptica: seguridad óptica
No mire nunca al láser de transmisión mientras esté encendido. No mire
nunca directamente al puerto de transmisión de fibra óptica ni a los
extremos del cable de fibra óptica mientras estén conectados.
ADVERTENCIA: Este dispositivo dispone de más de una entrada de
alimentación. Desconecte todas las entradas de alimentación del
dispositivo.
ADVERTENCIA: La instalación del sistema de alimentación superflua
(RPS) sólo debería llevarla a cabo personal cualificado y con la debida
formación.
ADVERTENCIA: Estas instrucciones deben leerse junto con las
instrucciones de instalación y seguridad que se facilitan con el sistema
RPS.
ADVERTENCIA: al encender cualquier Switch 5500 desde un RPS, la
unidad debe contar con una toma de tierra (conexión a tierra). Esto se
puede conseguir conectando el cable de alimentación de la unidad o bien
conectando el terminal de tierra en la parte posterior de la unidad a una
DISPOSITIVO LÁSER
DE CLASE 1
DUA1715-0AAA02.book Page 92 Wednesday, March 23, 2005 11:17 AM
Importanti Informazioni di Sicurezza
93
toma de tierra fiable, o conectando ambas. Deberá asegurarse de que la
conexión a tierra se realiza antes de conectar el suministro de CC del RPS.
ADVERTENCIA: Todos los RPS deben estar homologados como salidas
SELV sin toma de tierra según IEC 60950-1/UL 60950-1/EN 60950-1.
ADVERTENCIA: Estas instrucciones deben leerse junto con las
características de la entrada de suministro de CC del Switch 5500 del
Apéndice C, Especificaciones técnicas.
ADVERTENCIA: al conectar el cable al RPS deberán seguirse las
recomendaciones del fabricante.
ADVERTENCIA: asegúrese de que el disyuntor del RPS se encuentra en la
posición de abierto (desactivado) al conectar el cable al RPS.
ADVERTENCIA: deberá asegurarse de que el terminal positivo del Switch
está conectado al terminal positivo (común) del RPS, y de que el terminal
negativo del Switch está conectado al terminal negativo (disyuntor) del
RPS.
ADVERTENCIA: asegúrese de que el disyuntor del RPS se encuentra en la
posición de abierto (desactivado) al conectar el cable del RPS y el conector
al Switch 3Com.
Importanti Informazioni di Sicurezza
AVVERTENZA: Le operazioni di installazione e rimozione dell'unità
devono essere eseguite esclusivamente da personale qualificato.
AVVERTENZA: Se si installa lo 5500 in uno stack con unità SuperStack II
o SuperStack 3 più strette del modello 5500, posizionare lo 5500 sotto
tali unità.
AVVERTENZA: L'unità deve disporre di messa a terra.
AVVERTENZA: Per rispettare gli standard di sicurezza, è necessario
collegare l'unità a una fonte di alimentazione dotata di messa a terra.
DUA1715-0AAA02.book Page 93 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
AVVERTENZA: Set dei cavi di alimentazione
Deve essere approvato per il paese in cui viene utilizzato.
AVVERTENZA: L'accoppiatore (il connettore all'unità e non la spina a
muro) deve avere una configurazione abbinabile a una presa
EN60320/IEC320.
AVVERTENZA: La presa deve trovarsi vicino all'unità ed essere facilmente
accessibile.
AVVERTENZA: Questa unità funziona alle condizioni SELV (Safety Extra
Low Voltage) previste dalla norma IEC 60950. Tali condizioni sono
mantenute solo se anche l'apparecchiatura a cui è collegata opera nelle
stesse condizioni.
AVVERTENZA: Solo per Francia e Perù. Questa unità non può ricevere
alimentazione di tipo IT†. Se l'alimentazione è di tipo IT, l'unità deve
essere alimentata a 230 V (2P+T) tramite un trasformatore di isolamento
con rapporto 1:1, con il punto di collegamento secondario
Stati Uniti e
Canada
■
Il cavo deve avere l'approvazione UL e la certificazione CSA
■
La specifica minima per il cavo flessibile è: N. 18 AWG Tipo
SV o SJ 3 conduttori
■
Il set di cavi deve avere una capacità nominale di almeno
10 A.
■
La spina di collegamento deve essere dotata di messa a
terra, con configurazione NEMA 5-15P (15 A, 125 V) o
NEMA 6-15P (15 A, 250 V).
Solo Regno
Unito
■
La spina di alimentazione deve essere conforme BS1363 (3
pin 13 amp) e dotata di un fusibile da 5 A conforme
BS1362.
■
Il cavo dell'alimentazione di rete deve essere
contrassegnato dai marchi o ed essere di
tipo H03VVF3GO.75 (minimo).
Solo Europa
■
La spina di alimentazione deve essere conforme CEE 7/7
(tipo "SCHUKO").
■
Il cavo dell'alimentazione di rete deve essere
contrassegnato dai marchi o ed essere di
tipo H03VVF3GO.75 (minimo).
Danimarca
■
La spina di alimentazione deve essere conforme alla
sezione 107-2-D1, standard DK2-1a o DK2
Svizzera
■
La spina di alimentazione deve essere conforme SEV/ASE
1011
DUA1715-0AAA02.book Page 94 Wednesday, March 23, 2005 11:17 AM
Importanti Informazioni di Sicurezza
95
contrassegnato come Neutro, collegato direttamente a terra.
†Impédance à la terre.
AVVERTENZA: Solo Regno Unito. Se si collega un modem alla porta
Console dello 5500, utilizzare solo un modem idoneo per il collegamento
con il sistema di telecomunicazioni.
AVVERTENZA: Le porte RJ-45 sono prese dati RJ-45 schermate. Non è
pertanto possibile utilizzarle come normali prese telefoniche né per
collegare l'unità a un PBX (Private Branch Exchange, centralino telefonico
privato) o a una rete telefonica pubblica. Collegare a queste porte solo
prese dati RJ-45, sistemi di telefonia o telefoni di rete. A queste prese
dati è possibile collegare cavi dati schermati o non schermati con prese
dati schermate o non schermate.
AVVERTENZA: Porte a fibre ottiche - Protezione degli occhi
Non guardare mai il laser di trasmissione attraverso uno strumento ottico
di ingrandimento quando è acceso. Non guardare mai direttamente la
porta TX a fibre ottiche e le estremità del cavo a fibre ottiche quando
sono accese.
AVVERTENZA: Il dispositivo presenta più punti di alimentazione. Per
spegnere il dispositivo, scollegare tutti i punti di alimentazione.
AVVERTENZA: le operazioni di installazione dell'RPS (Redundant Power
Supply) devono essere eseguite esclusivamente da personale qualificato e
opportunamente addestrato.
AVVERTENZA: queste istruzioni devono essere lette insieme alle
istruzioni di sicurezza e installazione fornite con l'RPS.
AVVERTENZA: se si accende uno Switch 5500 da un RPS, l'unità deve
disporre di messa a terra. Per accendere lo switch, è possibile collegare il
cavo di alimentazione all'unità, collegare il terminale di terra situato sul
retro dell'unità a una presa elettrica di terra sicura oppure collegarli
PRODOTTO LASER
CLASSE 1
DUA1715-0AAA02.book Page 95 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
entrambi. Prima di collegare l'alimentazione CC dell'RPS, è necessario
verificare la messa a terra.
AVVERTENZA: tutti gli RPS devono essere approvati come dispositivi di
uscita SELV non messi a terra in conformità con le norme IEC 60950-1/UL
60950-1/EN 60950-1.
AVVERTENZA: queste istruzioni devono essere lette insieme ai valori di
ingresso dell'alimentazione CC dello Switch 5500 che vengono forniti
nell'Appendice C, Specifiche tecniche.
AVVERTENZA: quando si collega il cavo all'RPS, si consiglia di rispettare
le raccomandazioni fornite dal fabbricante.
AVVERTENZA: durante il collegamento del cavo all'RPS, verificare che il
salvavita dell'RPS si trovi in posizione Acceso (spento).
AVVERTENZA: è necessario verificare che il polo positivo sullo switch sia
collegato al polo positivo (comune) dell'RPS e che il polo negativo sullo
switch sia collegto al polo negativo (salvavita) dell'RPS.
AVVERTENZA: prima di collegare il cavo RPS e il connettore allo switch
3Com, verificare che il salvavita si trovi in posizione Acceso (spento).
Ważne informacje o zabezpieczeniach
OSTRZEŻENIE: Instalacja i demontaż urządzenia mogą być
wykonywane tylko przez wykwalifikowany personel.
OSTRZEŻENIE: Podczas instalacji Switch 5500 w stosie z urządzeniami
SuperStack II lub SuperStack 3, które są węższe niż Switch 5500,
urządzenie Switch 5500 musi być zainstalowane pod węższym urządze-
niem.
OSTRZEŻENIE: Urządzenie musi być uziemione lub musi być
podłączone do uziemionego źródła zasilania w celu zapewnienia zgod-
ności z wymogami bezpieczeństwa.
OSTRZEŻENIE: Zestaw przewodów zasilania:
DUA1715-0AAA02.book Page 96 Wednesday, March 23, 2005 11:17 AM
Wa¿ne informacje o zabezpieczeniach
97
Niezbędna jest zgodność z przepisami kraju, w którym jest stosowany:
OSTRZEŻENIE: Złączka urządzenia (podłączona do przełącznika, a nie
do wtyczki ściennej) musi być odpowiednio dopasowana do normy
EN60320/IEC320 otworu wlotowego.
OSTRZEŻENIE: Gniazdo zasilające musi być umieszczone w pobliżu
urządzenia i musi być łatwo dostępne.
OSTRZEŻENIE: Urządzenie to pracuje w warunkach SELV (Safety Extra
Low Voltage – Bezpieczne niskie napięcie) zgodnie z normą IEC 60950.
Takie warunki są zachowane tylko, jeśli osprzęt, do którego jest
podłączone, również pracuje w warunkach SELV.
OSTRZEŻENIE: Sólo para Francia y Perú:
Esta unidad no puede recibir corriente de fuentes IT†. Si las fuentes de
suministro de corriente son de tipo IT, esta unidad debe recibir 230V
(2P+T) a través de un transformador aislador con relación 1:1, con el pun-
to de conexión secundario etiquetado como neutro conectado directa-
Stany
Zjednoczone i
Kanada
■
Zestaw przewodów musi posiadać zezwolenie UL oraz
certyfikat CSA.
■
Minimalna specyfikacja przewodu giętkiego: Przewód typu
SV lub SJ 3 o średnicy 18 wg specyfikacji AWG.
■
Zestaw przewodów musi posiadać pojemność prądu
znamionowego przynajmniej 10A.
■
Wtyczka musi być uziemiająca z układem typu NEMA
5-15P (15A, 125V) lub NEMA 6-15P (15A, 250V).
Wielka Brytania
■
Wtyczka musi być zgodna z normą BS1363 (3-pinowa 13
amperów) i musi być wyposażona w bezpiecznik 5A zgodny
z normą BS1362.
■
Przewód sieci zasilającej musi być oznaczony lub
i musi być typu H03VVF3g0.75 (minimum).
Europa
■
Wtyczka zasilająca musi być zgodna z normą CEE 7/7
(„SCHUKO”).
■
Przewód sieci zasilającej musi być oznaczony lub
i musi być typu H03VVF3g0.75 (minimum).
Dania
■
Wtyczka zasilająca musi być zgodna z sekcją 107-2-D1
normy DK2-1a lub DK2-5a.
Szwajcaria
■
Wtyczka zasilająca musi być zgodna z normą SEV/ASE
1011.
DUA1715-0AAA02.book Page 97 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
mente a tierra. †Impédance ŕ la terre.
OSTRZEŻENIE: Tylko Wielka Brytania:
Podczas podłączania modemu do portu konsoli Switch 5500 należy
stosować tylko modem odpowiedni do podłączenia do sieci telekomuni-
kacyjnej.
OSTRZEŻENIE: Porty RJ-45. Są to ekranowane gniazda danych RJ-45.
Nie mogą być używane jako tradycyjne gniazda telekomunikacyjne lub
stosowane do podłączenia urządzenia do publicznej sieci telefonicznej
lub centrali PBX. Do tych gniazd należy podłączać jedynie łącza danych
RJ-45, sieciowe systemy telefoniczne lub telefony sieciowe. Zarówno
osłonięte, jak i nieosłonięte przewody z danymi wraz z osłoniętymi lub
nieosłoniętymi wtykami mogą być podłączone do tych gniazd.
OSTRZEŻENIE: Porty światłowodowe – bezpieczeństwo
Nie wolno nigdy patrzeć na włączoną diodę laser transmisyjny przez
urządzenie wzmacniające. Nie wolno nigdy patrzeć bezpośrednio na port
włókna TX i końcówki światłowodów, jeśli są zasilane.
OSTRZEŻENIE: To urządzenie ma kilka punktów podłączenia zasilania.
Aby wyłączyć urządzenie, należy odłączyć wszystkie punkty zasilania.
OSTRZEŻENIE: Instalacja zasilacza nadmiarowego (RPS) powinna być
wykonywana przez odpowiednio przeszkolony i wykwalifikowany person-
el.
OSTRZEŻENIE: Te instrukcje należy przeczytać razem z instrukcjami
dotyczącymi bezpieczeństwa i instalacji dostarczonymi z systemem zasi-
lania nadmiarowego.
OSTRZEŻENIE: Jeśli dowolny przełącznik Switch 5500 jest zasilany z
zasilacza RPS, urządzenie musi być uziemione. Można to uzyskać przez
podłączenie przewodu zasilającego do urządzenia lub przez podłączenie
końcówki uziemienia z tyłu urządzenia do dobrego elementu uziemi-
ającego. Należy upewnić się, że urządzenie zostało uziemione przed
podłączeniem zasilacza prądu stałego do zasilacza RPS.
LASER PRODUKT
KLASA 1
DUA1715-0AAA02.book Page 98 Wednesday, March 23, 2005 11:17 AM
Wa¿ne informacje o zabezpieczeniach
99
OSTRZEŻENIE: Wszystkie zasilacze RPS muszą mieć certyfikat nieuzi-
emionego źródła zasilania SELV zgodny z normami IEC 60950-1/UL
60950-1/EN 60950-1.
OSTRZEŻENIE: Te instrukcje należy przeczytać razem z charaktery-
styką zasilającego prądu stałego przełącznika Switch 5500 opisaną w
Dodatku C, Specyfikacja techniczna.
OSTRZEŻENIE: Podczas podłączania kabla do zasilacza RPS należy
przestrzegać zaleceń producenta.
OSTRZEŻENIE: Podczas podłączania kabla do zasilacza RPS należy
upewnić się, że wyłącznik w zasilaczu jest w pozycji otwartej (wyłączony).
OSTRZEŻENIE: Należy upewnić się, że końcówka dodatnia przełącznika
jest podłączona do dodatniej (wspólnej) końcówki zasilacza RPS, a ujem-
na końcówka przełącznika jest podłączona do ujemnej końcówki
(wyłącznika) zasilacza RPS.
DUA1715-0AAA02.book Page 99 Wednesday, March 23, 2005 11:17 AM
APPENDIX A: SAFETY INFORMATION
DUA1715-0AAA02.book Page 100 Wednesday, March 23, 2005 11:17 AM