Cajun P332MF User’s Guide

i Contents List of Figures.......................................................................................... ix List of Tables............................................................................................ xi Chapter 1 Overview.................................................................................................. 1 Cajun P330 Family Features .................................................................... 1 Layer 2 Features....................................................................................... 2 Auto-Negotiation ...........................................................................2 Congestion Control ........................................................................ 2 VLANs ............................................................................................ 2 Link Aggregation Group (LAG) ..................................................... 2 IP Multicast Filtering ...................................................................... 2 Radius Security .............................................................................. 3 Port Redundancy ...........................................................................3 Intermodule Redundancy ..............................................................3 Stack Redundancy ......................................................................... 3 Hot-Swappable ............................................................................... 4 Backup Power Supply ....................................................................4 Fans ................................................................................................ 4 Network Management Agent (NMA) Redundancy .......................4 Software Download ....................................................................... 4 Cajun P330 Standards Supported ............................................................ 5 IEEE ............................................................................................... 5 IETF ................................................................................................ 5 Cajun P330 Network Management.......................................................... 5 Cajun P330 Device Manager (Embedded Web) ............................. 5 Cajun P330 Command Line Interface (CLI) .................................. 5 CajunView™ .................................................................................. 5 Cajun P330 Network Monitoring............................................................. 6 RMON MIBs - RFC 1757 ............................................................... 6 SMON MIBs - RFC 2613 ................................................................ 6 Port Mirroring ................................................................................ 6 SMON ............................................................................................ 6 Chapter 2 Cajun P332MF Front and Back Panels..................................................... 7 Cajun P332MF Front Panel...................................................................... 7 Cajun P330 Back Panel .......................................................................... 11 BUPS Input Connector .................................................................11

Cajun P332MF User’s Guide

Chapter 3 Applications............................................................................................ 13 Application 1 .......................................................................................... 13 Application 2 .......................................................................................... 14 Application 3 .......................................................................................... 15 Chapter 4 Installation and Setup ............................................................................ 17 Installing Stacking Sub-modules............................................................ 17 Installing the Stacking Sub-module in the Cajun P330 ...............17 Positioning.............................................................................................. 17 Rack Mounting....................................................................................... 18 Connecting Stacked Switches................................................................. 19 To connect stacked switches: .......................................................19 Installing Expansion Sub-modules......................................................... 21 Installing the Expansion Sub-module into the Cajun P330 .........21 Removing an Existing Expansion Sub-module ............................21 Powering On – Cajun P330 Module AC................................................. 22 Powering On – Cajun P330 Module DC................................................. 22 Configuring the Switch .......................................................................... 23 Cajun P330 Default Settings ........................................................23 Switch Settings ...................................................................23 Port Settings .......................................................................24 Cabling .........................................................................................25 Connecting to the Serial Port .............................................26 Assigning Cajun P330’s IP Stack Address .....................................26 Changing the IP Address using Command Line Interface (CLI, Terminal Emulation) ..........................................................26 Chapter 5 Cajun Campus CLI - Architecture, Access & Conventions..................... 29 CLI Architecture..................................................................................... 29 Establishing a Serial Connection............................................................ 30 Establishing a Telnet Connection........................................................... 30 Command Line Prompt.......................................................................... 31 Cajun P330 Sessions............................................................................... 31 Security Levels ....................................................................................... 32 Entering the Supervisor Level ......................................................32 Defining new users ............................................................32 Exiting the Supervisor Level ..............................................32 Entering the CLI ...........................................................................33 Entering the Technician Level .....................................................33 Conventions Used .................................................................................. 33 Navigation, Cursor Movement and Shortcuts........................................ 34 Getting Help ........................................................................................... 34 Command Syntax................................................................................... 34 Command Abbreviations .............................................................34 Universal Commands ............................................................................. 35

Cajun P332MF User’s Guide

iii Top and Up commands ................................................................35 Retstatus command ......................................................................35 Tree command .............................................................................35 Chapter 6 Cajun Campus CLI – Layer 2 ................................................................. 37 User Level Commands ........................................................................... 37 Session Command ........................................................................38 Terminal Commands ....................................................................38 Clear screen Command ................................................................39 Ping Command ............................................................................39 Show Commands Summary Table ...............................................39 Show time Command ..................................................................41 Show timezone Command ..........................................................41 Show ntp Command ....................................................................41 Show ip route Command .............................................................42 Show image version Command ...................................................42 Show snmp Command ................................................................43 Show snmp retries Command .....................................................43 Show snmp timeout Command ...................................................43 Show timeout Command .............................................................44 Show interface Command ...........................................................44 Show port Command ...................................................................45 Show port trap Command ...........................................................46 Show port channel Command .....................................................46 Show port redundancy Command ..............................................47 Show port mirror Command .......................................................47 Show module Command .............................................................47 Show flowcontrol Command .......................................................48 Show cam Commands .................................................................49 Show trunk Command ................................................................50 Show spantree Command ............................................................51 Show autopartition Command ....................................................53 Show license Command ..............................................................53 Show system Command ..............................................................53 Show internal buffering Command .............................................54 Show intermodule port redundancy Command ..........................54 RMON Tools .................................................................................55 Show rmon statistics Command ..................................................55 Show rmon history Command ....................................................55 Show rmon alarm Command ......................................................56 Show rmon event Command ......................................................56 Show tftp download/upload status Command ............................57 Show tftp download software status Command ..........................57 Show web aux-files-url Command ..............................................57 Show intelligent-multicast command ..........................................58

Cajun P332MF User’s Guide

Show intelligent-multicast hardware-support Command ...........58 Show secure mac Command ........................................................59 Show security mode Command ...................................................59 Show port security Command .....................................................59 Dir Command ...............................................................................60 Privileged Level Commands ................................................................... 62 No hostname Command ..............................................................63 No rmon history Command .........................................................63 No rmon alarm Command ...........................................................63 No rmon event Command ...........................................................63 Hostname Command ...................................................................64 Clear Commands Summary Table ...............................................64 Clear timezone Command ...........................................................64 Clear ip route Command ..............................................................64 Clear snmp trap Command ..........................................................65 Clear vlan Command ...................................................................65 Clear cam Command ....................................................................66 Clear log Command .....................................................................66 Clear port mirror Command ........................................................66 Clear secure mac Command ........................................................66 Set Commands Summary Table ...................................................67 Set logout Command ...................................................................69 Set timezone Command ...............................................................70 Set ntp server Command .............................................................70 Set ip route Command .................................................................70 Set snmp trap Commands ............................................................71 Set snmp trap auth Command .....................................................72 Set snmp retries Command ..........................................................72 Set snmp timeout Command .......................................................73 Set system location Command .....................................................73 Set system name Command .........................................................73 Set system contact Command ......................................................73 Set interface Command ................................................................74 Set port level Command ..............................................................74 Set port negotiation Command ....................................................75 Set port enable Command ...........................................................75 Set port disable Command ...........................................................75 Set port speed Command .............................................................76 Set port duplex Command ...........................................................76 Set port name Command .............................................................76 Set port trap Command ................................................................77 Set port vlan Command ...............................................................77 Set port channel Command .........................................................78 Set port redundancy on/off Command ........................................78

Cajun P332MF User’s Guide

v Set port redundancy Commands .................................................79 Set port mirror Command ...........................................................79 Set inband vlan Command ..........................................................80 Set flowcontrol Command ...........................................................80 Set auto-negotiation-flowcontrol-advertisement Command .......81 Set trunk Command ....................................................................82 Set spantree Commands ..............................................................82 Set spantree priority Command ...................................................83 Set autopartition Command ........................................................83 Set license Command ...................................................................83 Set internal buffering Command .................................................84 Set intermodule port redundancy Command ..............................84 Set web aux-files-url Command ..................................................85 Set intelligent-multicast Command .............................................85 Set intelligent-multicast client port pruning time Command ......85 Set intelligent-multicast router port pruning time Command .....86 Set intelligent-multicast group filtering delay time Command ...86 Set secure mac Command ............................................................86 Set security mode Command .......................................................87 Set port security Command .........................................................87 Sync time Command ...................................................................87 Get time Command ......................................................................88 Reset Command ...........................................................................88 Nvram initialize Command ..........................................................89 Configure Command ...................................................................89 Rmon history Command .............................................................89 Rmon alarm Command ...............................................................90 Rmon event Command ................................................................91 Copy stack-config tftp Command ................................................91 Copy module-config tftp Command ............................................92 Copy tftp stack-config Command ................................................93 Copy tftp module-config Command ............................................93 Copy tftp EW_archive Command ................................................94 Copy tftp SW_image Command ..................................................94 Supervisor Level Commands ................................................................. 95 Username Command ...................................................................95 No username Command ..............................................................95 Show username Command .........................................................95 Show radius authentication Command .......................................96 Set radius authentication Command ...........................................96 Set radius authentication secret Command .................................96 Set radius authentication server Command ................................97 Clear radius authentication server Command .............................97 Set radius authentication retry-time Command ..........................97

Cajun P332MF User’s Guide

Set radius authentication retry-number Command ....................97 Set radius authentication udp-port Command ............................98 Appendix A Cajun P330 Embedded Web Manager ................................................................ 99 System Requirements............................................................................. 99 Running the Embedded Manager ........................................................ 100 Installing the Java Plug-in.................................................................... 103 Installing the On-Line Help and Java Plug-In on your Web Site......... 104 Documentation..................................................................................... 104 Software Download.............................................................................. 104 Appendix B Specifications .................................................................................................... 105 Cajun P332MF Switch.......................................................................... 105 Physical ......................................................................................105 Power Requirements – AC .........................................................105 Power Requirements – DC .........................................................105 Laser Data ..................................................................................106 Environmental ...........................................................................106 Safety .........................................................................................106 Cajun P330 DC Input Version ....................................................106 EMC Emissions ...........................................................................107 Emissions .........................................................................107 Immunity .........................................................................107 Interfaces ....................................................................................107 Standards Compliance ................................................................107 IEEE .................................................................................107 IETF ..................................................................................107 Basic MTBF ................................................................................107 Stacking Sub-module ........................................................................... 108 Expansion Sub-modules....................................................................... 108 Gigabit Ethernet Expansion Sub-modules .................................108 Laser Safety ......................................................................108 Laser Classification ...........................................................109 Usage Restriction ..............................................................109 Laser Data ........................................................................109 Fast Ethernet Fiber Expansion Sub-module ..............................110 Ethernet/Fast Ethernet Expansion Sub-module ........................110 GBIC Expansion Sub-module ....................................................110 Safety Information ...........................................................110 Usage Restriction ..............................................................111 Lucent Approved GBIC Transceivers ...............................111 Specifications ...................................................................112 Agency Approval .............................................................112 MTBF ...............................................................................112 X330GT2 Gigabit Ethernet Expansion Sub-module ..................112

Cajun P332MF User’s Guide

vii Installing the Expansion Sub-module in the Cajun P330 113 Removing an Existing Expansion Sub-module ............... 113 Cabling .............................................................................113 ATM Expansion Sub-modules ...................................................114 Safety Information ........................................................... 114 Backup Power Supply (BUPS) ............................................................. 115 Physical ...................................................................................... 115 Power Requirements .................................................................. 115 Environmental ........................................................................... 116 Safety ......................................................................................... 116 EMC Emissions .......................................................................... 116 Emissions ......................................................................... 116 Immunity ......................................................................... 116 BUPS MTBF ............................................................................... 116 MTBF in Various Configurations ......................................................... 117 Appendix C How to Contact Us............................................................................................ 119 From the United States: ...................................................119 From South America, and Central & Latin America (CALA): ........................................... 119 Outside North America: ...................................................119

Cajun P332MF User’s Guide

ix List of Figures Figure 2.1 Cajun P332MF Front Panel .................................................. 7 Figure 2.2 Cajun P332MF LEDs............................................................. 8 Figure 2.3 Cajun P330 AC and DC Back Panels ..................................11 Figure 3.1 Cajun P330 stacks with a Cajun P550 Backbone ...............13 Figure 3.2 Cajun P330 stacks with a Cajun 330 backbone..................14 Figure 3.3 Cajun P332MF with a Cajun P880 backbone.....................15 Figure 4.1 Cajun P330 Rack Mounting ...............................................18 Figure 4.2 Incorrect Stack Connection ................................................20 Figure 4.3 Cajun P330 Stack Connections...........................................20 Figure A.1 The Welcome Page............................................................ 100 Figure A.2 Web-based Manager ......................................................... 101 Figure A.3 Options for Installing the Java Plug-in ............................. 102

Cajun P332MF User’s Guide

xi List of Tables Table 2.1 Cajun P332MF LED Descriptions.......................................... 9 Table 2.2 Cajun P330 <- -> Select buttons.........................................10 Table 4.1 Default Switch Settings.......................................................23 Table 4.2 Default Port Settings...........................................................24 Table 4.3 Gigabit Ethernet Cabling ....................................................25 Table 5.1 Navigation, Cursor Movement and Shortcuts ....................34 Table B.1 Stacking Sub-module........................................................ 108 Table B.2 Gigabit Ethernet Expansion Sub-modules........................ 108 Table B.3 Fiber Fast Ethernet Expansion Sub-module..................... 110 Table B.4 Ethernet/Fast Ethernet Expansion Sub-module............... 110 Table B.7 MTBF for the Cajun P332MF in Various Configurations . 117

Cajun P332MF User’s Guide

1 Chapter 1 Overview The Cajun™ P330 family of stackable Ethernet workgroup switches includes a range of modules with 10/100/1000 Mbps ports and a Layer 3 capability/ATM Expansion sub-module. The Cajun P332MF switch has 12x100BaseFX MT-RJ ports and an Expansion sub-module slot. The optional expansion sub-modules provide additional Ethernet, Fast Ethernet, and Gigabit Ethernet connectivity. A Cajun P330 stack can contain up to 10 switches and up to 3 backup power supply units. The stacked switches are connected using the Cajun X330STK stacking sub- modules which plug into a slot in the back of the Cajun P330. They are connected using the X330SC or X330LC cable (if the stack is split between 2 racks). The Cajun X330RC cable connects the top and bottom switches in the stack and provides redundancy and hot-swappability in the same way that modules can be swapped in a modular switching chassis. The Cajun P330 is fully compliant with IEEE standards for VLAN Tagging, Gigabit Ethernet, Spanning Tree and Flow Control. This full standards-compliance, combined with auto-negotiation for 10/100/1000 Mbps and half/full duplex facilitates the expansion of your network to match your company's growing needs. Cajun P330 Family Features • You can connect up to 10 Cajun P330 switches in a stack. Moreover, this stack can be either in one rack or split over several racks using the X330LC Long Cable, according to your requirements. • Cajun X330STK - this stacking sub-module is used to connect Cajun P330 switches in a stack, via the Octaplane. • Cajun P330 BUPS - this back-up power supply module supports up to four Cajun P330 switches. • One RJ-45/RS232 front panel console connector for both terminal and modem (future) sessions. • Two fan units in every switch, with operation sensors. • One virtual IP address for managing the whole stack, the P330 stack is managed as a single entity. • Hot-swapping of one switch at a time - by activation of the redundant cable: — Does not disrupt the operation of other Cajun P330 switches. — Does not change stack configuration. — Does not require network downtime. • Connection through Telnet from the front panel ports of any switch, with: — multiple levels of password protection — login and inactivity timeouts

Cajun P332MF User’s Guide

Layer 2 Features Auto-Negotiation Every 10/100 port on the Cajun P330 supports Auto-Negotiation which automatically detects and supports the operating mode and speed of a connected device. Auto-negotiation is also supported on the Gigabit Ethernet ports for flow control mode only. This means that you can simply connect the Cajun P330 to Ethernet or Fast Ethernet equipment at full or half duplex without configuration. Congestion Control Congestion control is a key element of maintaining network efficiency as it prevents resource overload. The Lucent Cajun P330 supports congestion control on all Ethernet ports, using the following: • Back Pressure in half duplex mode • IEEE 802.3x Flow Control in full duplex mode VLANs The Cajun P330 VLANs are fully IEEE 802.1Q compliant and can handle up to 3k tagged VLANs. Special VLAN (Virtual Sideband) for management provides physical security for key applications. Link Aggregation Group (LAG) LAG provides increased bandwidth and redundancy for critical high-bandwidth applications such as inter-stack links and connections to servers. You can aggregate the bandwidth of up to eight 10/100Base-Tx ports, two 100Base-FX or 1000Base-X ports. Load sharing ensures that if one of the port connections fails, the other connections will assume the load seamlessly. Load balancing guarantees that the traffic load at any level will be evenly divided among all the LAG links. IP Multicast Filtering IP Multicast allows you to send a single copy of an IP packet to multiple destinations, and can be used for various applications including video streaming and video conferencing. On LANS, IP Multicast packets are transmitted in MAC Multicast frames. Traditional LAN switches flood these Multicast packets to all stations in the VLAN.

Cajun P332MF User’s Guide

3 Multicast filtering functions may be added to the Layer 2 switches to avoid sending Multicast packets where they are not required. Layer 2 switches capable of Multicast filtering send the Multicast packets only to ports that connect members of that Multicast group. This is typically based on IGMP snooping, GMRP or CGMP. Note: To operate IP Multicast filtering with IGMP snooping, Hardware Ver. C/S 2.0 or higher is mandatory. Radius Security The Remote Authentication Dial-In User Service (RADIUS) is an IETF standard (RFC 2138) client/server security protocol. Security and login information is stored in a central location known as the RADIUS server. RADIUS clients such as the Cajun P330, communicate with the RADIUS server to authenticate users. All transactions between the RADIUS client and server are authenticated throught the use of a “shared secret” which is not sent over the network. The shared secret is an authentication password configured on both the RADIUS client and its RADIUS servers. The shared secret is stored as clear text in the client’s file on the RADIUS server, and in the non-volatile memory of the Cajun P330. In addition, user passwords are sent between the client and server are encrypted for increased security. Port Redundancy Redundancy can be implemented between any two ports in the same stack at the link level. You can also assign redundancy between any two LAGs in the stack or between a LAG and a port. One port or LAG is defined as the primary port, and the other as the secondary port. In case the primary port link fails, the secondary port takes over. Intermodule Redundancy Intermodule redundancy includes all Port Redundancy functionality. Intermodule redundancy maintains port integrity even when the primary port link fails as the result of a failure of the module. If the module on which the primary port in an Intermodule Port Redundancy is powered down or removed from the device, the secondary port in the Intermodule Port Redundancy takes over. Only one module per stack must be set for Intermodule Port Redundancy. Stack Redundancy In the unlikely event that a Cajun P330 switch or Octaplane link should fail, stack integrity is maintained. The broken link is bypassed and data transmission

Cajun P332MF User’s Guide

continues uninterrupted. The single management IP address for the stack is also preserved for uninterrupted management and monitoring. Hot-Swappable You can remove or replace any unit within the stack without disrupting operation or performing stack-level reconfiguration. You can therefore adapt the P330 to your requirements on the fly and with a down-time which is second to none. Backup Power Supply Each Cajun P330 basic unit comes with a Backup Power Supply (BUPS) connector. If the internal power supply should fail, the Cajun P330 BUPS (available separately,) will automatically supply power to the switch for uninterrupted operation. Fans The Cajun P330 base unit fans have integrated sensors which provide advance warnings of fan failure via management. Network Management Agent (NMA) Redundancy Since each Cajun P330 module has an integral SNMP agent, any module in a stack can serve as the stack NMA while other NMAs act as redundant agents in “hot” standby. If the “live” NMA fails then a backup is activated instantaneously. Software Download Safe S/W download procedure – backup code always present.

Cajun P332MF User’s Guide

5 Cajun P330 Standards Supported The Cajun P330 complies with the following standards. IEEE • 802.3x Flow Control on all ports • 802.1Q VLAN Tagging support on all ports and 802.1p compatible • 802.1D Bridges and STA • 803.2z Gigabit Ethernet ports • 803.2u Ethernet/Fast Ethernet ports IETF • MIB-II - RFC 1213 • Bridge MIB for Spanning Tree - RFC 1492 • RMON - RFC 1757 • SMON - RFC 2613 Cajun P330 Network Management Comprehensive network management is a key component of today’s networks. Therefore we have provided multiple ways of managing the Cajun P330 to suit your needs. Cajun P330 Device Manager (Embedded Web) The built-in Cajun P330 Device Manager (Embedded Web Manager) allows you to manage a Cajun P330 stack using a Web browser without purchasing additional software. This application works with the Microsoft® Internet Explorer and Netscape® Navigator web browsers and Sun Microsystems Java™ Plug-in. Cajun P330 Command Line Interface (CLI) The Cajun P330 CLI provides a terminal type configuration tool for local or remote configuration of Cajun P330 features and functions. CajunView™ When you need extra control and monitoring or wish to manage other Cajun Campus equipment, then the CajunView network management suite is the answer. This suite provides the ease-of-use and features necessary for optimal network utilization. • CajunView is available for Windows® 95/NT®. • CajunView operates under HP OpenView.

Cajun P332MF User’s Guide

Cajun P330 Network Monitoring RMON MIBs - RFC 1757 • RMON support for groups 1,2,3 and 9 — Statistics — History — Alarms — Events SMON MIBs - RFC 2613 • SMON support for groups — Data Source Capabilities — Port Copy — VLAN and Priority Statistics Port Mirroring The Cajun P330 provides port mirroring for additional network monitoring functionality. You can filter the traffic and mirror either incoming traffic to the source port or both incoming and outgoing traffic. This allows you to monitor the network traffic you need. SMON The Cajun P330 supports Lucent’s ground-breaking SMON Switched Network Monitoring, which the IETF has now adopted as a standard (RFC2613). SMON provides an unprecedented top-down monitoring of switched network traffic at the following levels: • Enterprise Monitoring • Switch Monitoring • VLAN Monitoring • Port-level Monitoring This top-down approach gives you rapid troubleshooting and performance trending to keep the network running optimally. Note: CajunView is required to run SMON monitoring. Note: You need to purchase one SMON License per Cajun P330 Stack.

Cajun P332MF User’s Guide

7 Chapter 2 Cajun P332MF Front and Back Panels Cajun P332MF Front Panel The Cajun P332MF front panel contains LEDs, controls, connectors and an expansion sub-module slot, as well as a console connector. The status LEDs and control buttons provide at-a-glance information. The front panel LEDs consist of Port LEDs and Function LEDs. The Port LEDs display information for each port according to the illuminated function LED. The function is selected by pressing the left or right button until the desired parameter LED is illuminated. For example, if the COL LED is illuminated, then all Port LEDs show the collision status of their respective port. If you wish to select the LAG function, then press the right button until the LAG Function LED is lit; if you then wish to select Rx then press the left button several times until the Rx function LED lights. Figure 2.1 shows the Cajun P332MF front panel. Figure 2.2 shows a detailed view of the LEDs (described in Table 2.1), pushbuttons, the Expansion sub-module slot, and the RJ-45 console connector at the bottom right. Figure 2.1 Cajun P332MF Front Panel

Cajun P332MF Front and Back Panels

8 Cajun P332MF User’s Guide Figure 2.2 Cajun P332MF LEDs Note: All LEDs are lit during a reset. 1 2 3 4 5 6 7 8 9 10 11 12 FC Hspd LAG PWR OPR SYS LNK COL Tx FDX Rx FIV Function LEDs Port LEDs Left/Right and Reset (both) Switches FIV Switch EXPANSION SLOT 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66

Cajun P332MF Front and Back Panels

Cajun P332MF User’s Guide 9 Table 2.1 Cajun P332MF LED Descriptions LED Name Description LED Status PWR Power status OFF – power is off ON – power is on Blink – using BUPS only OPR CPU operation OFF – Module is booting ON – Normal operation SYS System Status OFF – Module is a slave in a stack ON – Module is the Master of the stack and the Octaplane and Redundant cable are connected correctly. This LED will also light in Standalone mode. Blink – Box is the Master of the stack and the stack is in redundant mode. The following Function LEDs apply to ports 1 to 66 LNK Port status OFF – Port disabled ON – Port enabled and link OK Blink – Port enabled and the link is down COL Collision OFF – No collision or FDX port ON – Collision occurred on line Tx Transmit to line OFF – No transmit activity ON – Data transmitted on line from the module Rx Receive from line OFF – No receive activity ON – Data received from the line into the module FDX Half/Full Duplex OFF – Half duplex mode ON – Full duplex mode

Cajun P332MF Front and Back Panels

10 Cajun P332MF User’s Guide Note: To perform “Force Initial Version” reset the module and at the same time press the FIV reset button (use an opened paper clip or other pointed object). Release the reset buttons first and 1 or 2 seconds later, release the FIV button. Note: The Port LEDs of the P332MF are numbered from 1-12. Expansion sub- module ports are numbered from 51. Port LED numbers 49-50 are reserved. FC Symmetric Flow Control OFF – No Flow Control only and/or while in half duplex mode ON – Symmetric/Asymmetric Flow Control mode is enabled and port is in full duplex mode. Hspd High Speed 10/100 1000 OFF: 10 N/A ON: 100 1000 LAG Link Aggregation Group (Trunking) OFF – No LAG defined for this port ON – Port belongs to a LAG Table 2.2 Cajun P330 <- -> Select buttons Description Function Left/Right Individual – select LED function (see table above). Reset module Press both right and left buttons together for approximately two seconds. All LEDs on module light up until buttons are released. Reset stack Press both right and left buttons together for 4 seconds. All LEDs on stack light up until buttons are released. FIV Force Initial Version – boot from backup initial version of the Cajun P330 software, from Bank A (see Note below). Table 2.1 Cajun P332MF LED Descriptions LED Name Description LED Status

Cajun P332MF Front and Back Panels

Cajun P332MF User’s Guide 11 Cajun P330 Back Panel The Cajun P330 back panel contains a stacking sub-module slot, power supply and BUPS connector. Figure 2.3 shows the back panel of the AC switch (top) and the DC switch (bottom) with a stacking sub-module installed. Figure 2.3 Cajun P330 AC and DC Back Panels Note: Any further illustrations of the Cajun P330 Back Panel will be that of the AC model, the topmost panel in Figure 2.3. BUPS Input Connector The BUPS input connector (see Figure 2.3) is a 5 V DC connector for use with the Cajun P330 BUPS unit only. BUPS Input

Cajun 332MF User’s Guide

13 Chapter 3 Applications The following sections describe typical applications for the Cajun P330 in a network with other Cajun Campus products. Application 1 This application shows Cajun P550 as the network backbone with Cajun P330 stacks as closet devices with LAG and redundant links. Figure 3.1 Cajun P330 stacks with a Cajun P550 Backbone Cajun P550 Cajun P330 Cajun P330 10/100 Mbps Ethernet 10/100 Mbps Ethernet 10/100 Mbps Ethernet Gigabit Ethernet with LAG Redundant LAG 100 Mbps Ethernet (Fiber) with LAG Gigabit Ethernet with LAG 4x100 Mbps LAG 4x100 Mbps LAG

Cajun P332MF User’s Guide

Application 2 This application shows a Cajun P330 stack forming the backbone of a Small/ Medium-sized Enterprise (SME) network with CajunP330 stacks as closet devices with LAN and redundant links. Figure 3.2 Cajun P330 stacks with a Cajun 330 backbone Cajun P330 10/100 Mbps Ethernet 10/100 Mbps Ethernet 10/100 Mbps Ethernet Gigabit Ethernet with LAG 4x100 Mbps LAG 4x100 Mbps LAG Cajun P330 Gigabit Ethernet with LAG LAG Redundancy

Cajun 332MF User’s Guide

15 Application 3 This application shows Cajun P880 as the network backbone with Cajun P332MF deployed as a distribution switch. A Cajun P333R multilayer switch provides local IP routing. The Cajun P333T stacks act as closet devices with LAG and redundant links. Figure 3.3 Cajun P332MF with a Cajun P880 backbone Cajun P332MF 10/100 Mbps Ethernet 10/100 Mbps Ethernet Cajun P880 Cajun P332MF Cajun P333R Server Farm 10/100 Mbps Eth 100 Mbps Fiber Optic Ethernet with LAG 100 Mbps Fiber Optic Ethernet with LAG 10/100 Mb Ethernet 10/100 Mbps Ethernet Gigabit Ethernet with LAG LAG Redundancy LAG Redundancy LAG Redundancy Gigabit Ethernet with LAG 4x100 Mbps LAG Cajun P880

Cajun P332MF User’s Guide

17 Chapter 4 Installation and Setup The Cajun P332MF is ready to work after you carry out the installation instructions given below. All the Cajun P332MF ports provide complete connectivity and no configuration is required to make the system work. Installing Stacking Sub-modules Caution: The stacking sub-modules contain components sensitive to electrostatic discharge. Do not touch the circuit board unless instructed to do so. Installing the Stacking Sub-module in the Cajun P330 1 Remove the blanking plate from the back of the Cajun P330 switch. 2 Insert the stacking sub-module gently into the slot, ensuring that the metal base plate is aligned with the guide rails. The metal plate of the X330STK (and not the PCB) fits onto the guide rails. 3 Press the sub-module in firmly until it is completely inserted into the Cajun P330. 4 Gently tighten the two screws on the side panel of the stacking sub-module by turning them. Note: The Cajun P330 switch must not be operated with the back-slot open; the stacking sub-module should be covered with the supplied blanking plate if necessary. Positioning Cajun P330 can be mounted alone or in a stack in a standard 19-inch equipment rack in a wiring closet or equipment room. Up to 10 units can be stacked in this way. When deciding where to position the unit, ensure that: • It is accessible and cables can be connected easily and according to the configuration rule. • Cabling is away from sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines and fluorescent lighting fixtures. • Water or moisture cannot enter the case of the unit. • Air-flow around the unit and through the vents in the back and sides of the case is not restricted.

Installation and Setup

18 Cajun P332MF User’s Guide Note: Use Octaplane cables to interconnect with other switches. Rack Mounting The Cajun P330 case fits in most standard 19-inch racks. Cajun P330 is 2U (88mm, 3.5”) high. Place the Cajun P330 in the rack as follows: 1 Snap open the hinged ends of the front panel to reveal the fixing holes. 2 Insert the unit into the rack. Ensure that the four Cajun P330 screw holes are aligned with the rack hole positions as shown in Figure 4.1. Figure 4.1 Cajun P330 Rack Mounting 3 Secure the unit in the rack using the screws. Use two screws on each side. Do not overtighten the screws. 4 Snap closed the hinged ends of the front panel. 5 Ensure that ventilation holes are not obstructed.

Installation and Setup

Cajun P332MF User’s Guide 19 Connecting Stacked Switches Note: The two ends of the Octaplane cable terminate with different connectors. Each connector can only be connected to its matching port. The following cables are used to connect stacked switches: • Short Octaplane cable (X330SC) – ivory-colored, used to connect adjacent switches (Catalog No. CB0223) or switches separated by a BUPS unit. • Long Octaplane cable (X330LC) – ivory-colored, used to connect switches from two different physical stacks, or switches separated by a BUPS unit (Catalog No. CB0225). • Redundant cable (X330RC) – black, used to connect the top and bottom switches of a stack (Catalog No. CB0222). To connect stacked switches: 1 Plug the light grey connector of the Short Octaplane cable into the port marked “to upper unit” of the bottom Cajun P330 switch. 2 Plug dark grey connector of same Short Octaplane cable to the port marked “to lower unit” in the unit above. The connections are illustrated in Figure 4.3. 3 Repeat Steps 1 and 2 until you reach the top switch in the stack. Note: If you have split the stack, use the Long Cable instead of the Short Cable where required. 4 If you wish to implement stack redundancy, use the Redundant Cable to connect the port marked “to lower unit” on the bottom switch to the port marked “to upper unit” on the top switch of the stack. Caution: Do not cross-connect two Cajun P330 switches with two Octaplane (light- colored) cables. If you wish to cross-connect for redundancy, use one light-colored Octaplane cable and one black redundancy cable. Figure 4.2 shows an incorrect connection. Note: You can build a stack of up to 10 Cajun P330 switches. If you do not wish to stack all the switches in a single rack, use long Octaplane cables to connect two physical stacks as shown in Figure 4.3.

Installation and Setup

20 Cajun P332MF User’s Guide Figure 4.2 Incorrect Stack Connection Figure 4.3 Cajun P330 Stack Connections Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector 5 4 3 2 1 Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Cable to Upper Unit Cable to Lower Unit Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector Power Supply Connector BUPS Connector 10 9 8 7 6 X330RC X330SC X330LC

Installation and Setup

Cajun P332MF User’s Guide 21 Installing Expansion Sub-modules Caution: The expansion sub-modules contain components sensitive to electrostatic discharge. Do not touch the circuit board unless instructed to do so. Installing the Expansion Sub-module into the Cajun P330 1 Remove the blanking plate or other sub-module (if installed). 2 Insert the sub-module gently into the slot, ensuring that the Printed Circuit Board (PCB) is aligned with the guide rails. The PCB not the metal base plate fits into the guide rail. 3 Firmly press the sub-module until it is completely inserted into the Cajun P330. 4 Gently tighten the two screws on the front panel of the expansion sub-module by turning them. Removing an Existing Expansion Sub-module 1 Loosen the screws by turning the knobs. 2 Take hold of the two knobs (one near each side of the front panel) and pull gently but firmly towards yourself. 3 Insert another expansion sub-module or the blanking plate. Note: The Cajun P330 switch must not be operated with the expansion slot open; the expansion sub-module slot should be covered with the supplied blanking plate if necessary. Note: Expansion sub-modules are hot-swappable and can be inserted or removed in an operating base unit.

Installation and Setup

22 Cajun P332MF User’s Guide Powering On – Cajun P330 Module AC For the AC input version of the Cajun P330, insert the power cord into the power inlet in the back of the unit. The unit powers up. 1 If you are using a BUPS, insert a power cord from the BUPS into the BUPS connector in the back of the unit. The unit powers up. 2 After power up or reset, the Cajun P330 performs a self test procedure. Powering On – Cajun P330 Module DC For the DC input version of the Cajun P330, connect the power cable to the switch at the input terminal block. 1 The terminals are marked “+”, “-“ and with the IEC 5019a Ground symbol. 2 The size of the three screws in the terminal block is M3.5. 3 The pitch between each screw is 9.5mm. Warning: Before performing any of the following procedures, ensure that DC power is OFF. Caution: This product is intended for installation in restricted access areas and is approved for use with 18 AWG copper conductors only. The installation must comply with all applicable codes. 4 Attach the appropriate lugs at the wire end of the power supply cord. 5 Wire the DC power supply to the terminal block. Warning: The proper wiring sequence is ground to ground, positive to positive (line to L), and negative to negative (neutral to N). Note that the ground wire should always be connected first and disconnected last.

Installation and Setup

Cajun P332MF User’s Guide 23 Configuring the Switch The Cajun P330 may be configured using the text-based Command Line Interface (CLI) utility, the built-in Cajun P330 Device Manager (Embedded Web) or CajunView™. For instructions on the text-based utility, see the CLI chapter. For instructions on installation of the graphical user interfaces, see the Cajun P330 Device Manager Appendix. For instructions on the use of the graphical user interfaces, refer to the Manager User’s Guide on the Management CD. Cajun P330 Default Settings The default settings for the Cajun P330 switch and its ports are determined by the Cajun P330 software. These default settings are subject to change in newer versions of the Cajun P330 software. See the Release Notes for the most up-to-date settings. Switch Settings Table 4.1 Default Switch Settings Function Default Setting Cajun P330 IP address 149.49.32.134 Default gateway 0.0.0.0 VLANs VLAN 1 Spanning tree Enabled Bridge priority for Spanning Tree 32768 NTP server IP address 0.0.0.0 Timezone offset 0 hours Read-only SNMP community string Public Read-write SNMP community string Public Trap SNMP community string Public SNMP retries number 3 SNMP timeout 2000 Seconds SNMP authentication trap Disabled CLI timeout 15 Minutes

Installation and Setup

24 Cajun P332MF User’s Guide Port Settings Note: Functions operate in their default settings unless configured otherwise. Table 4.2 Default Port Settings Function Default Setting 10/100Base-TX ports 100Base-F ports 1000 Base-X ports Duplex mode Full duplex Full duplex Full duplex only Speed mode 100M 100M 1000M Flow control Off Off Off Flow control advertisement Off N/A Off (No pause) Backpressure On (only in Half duplex) Not Applicable Not Applicable Autopartitioning Disabled (only in Half duplex) N/A N/A Auto-negotiation Enable Not Applicable Enable1 1Ensure that the other side is also set to Autonegotiation Enabled Administration status Enable Enable Enable Port VLAN 1 1 1 Tagging mode Clear Clear Clear Port priority Regular Regular Regular Spanning Tree cost 20 20 4 Spanning Tree port priority 128 128 128

Installation and Setup

Cajun P332MF User’s Guide 25 Cabling Cajun P330 modules include the following types of ports (according to the speed and standard they support): 10Base-T, 100Base-TX, 100Base-FX, 1000Base-SX and 1000Base-LX. Note: To interconnect Cajun P330 switches with twisted pairs, crossed cables are required. • The maximum UTP cable length connected to a 10/100 Mbps port operating as 10Base-T, is 100 m (328 ft.). • A UTP Category 5 cable must be connected to any 100Base-TX port, via an RJ45 connector. The maximum UTP cable length connected to a 10/100 Mbps port operating as 100Base-TX, is 100 m (328 ft.). • A fiberoptic cable must be connected to any 100Base-FX port, via a pair of SC connectors. The maximum fiber cable length connected to a 100Base-FX port is 412 m (1,352 ft) when operating in half duplex, and 2 km (6,562 ft) when operating in full duplex. • The maximum length of fiber optic cable connected to a 12 fiber MT-RJ port is 2 km (6,562 ft). Appropriate cables are available from your local supplier. *1000BASE-LX over Multimode fiber requires a special Patch cord cable which you can obtain from your local cable supplier. Table 4.3 Gigabit Ethernet Cabling Gigabit Interface Fiber Type Diameter (m) Modal Bandwidth Maximum Distance (m) 1000BASE-SX MM 62.5 160 220 1000BASE-SX MM 62.5 200 275 1000BASE-SX MM 50 400 500 1000BASE-SX MM 50 500 550 1000BASE-LX MM 62.5 500 550 1000BASE-LX MM 50 500 550 1000BASE-LX SM 9 NA 5,000 1000BASE-SLX SM 9 NA 10,000

Installation and Setup

26 Cajun P332MF User’s Guide Connecting to the Serial Port Cajun P330 has one serial port on the front of the switch for connecting a terminal, a terminal emulator, or a modem (future) using the supplied adapter. The RJ-45 port on the front of the switch is labeled “Console”, and may be used to configure the switch using the built-in Command Line Interface (CLI, Terminal Emulation). In the future, this connector will also be used for out-of-band SNMP management, via a modem. The port settings are as follows: • Baud Rate - 9600 bps • Character Size - 8 • Parity - None • Stop Bit - 1 • Flow Control - None • We recommend using a VT-100 terminal to enable access to all CLI features. The terminal connected to the serial port must be configured with the same settings; this setting will work with any PC COM port over a DB9 to RJ45 connector. Assigning Cajun P330’s IP Stack Address Note: All Cajun P330 switches are shipped with the same default IP address. In order to ensure that the stack has its own unique IP address in the network, you must change the IP address of the Master Cajun P330 switch in the stack . Changing the IP Address using Command Line Interface (CLI, Terminal Emulation) Use the CLI to assign the Cajun P330 stack an IP address and net mask. The CajunView station may establish communications with the stack once this address had been assigned and the stack inserted into the network. 1 Establish a serial connection by connecting a terminal to the Master Cajun P330 switch as described in the “Command Line Interface” chapter. 2 When the “Welcome to P330” menu appears and you are prompted for a Login Name, enter the default name root 3 When you are prompted for a password, enter the password root. You are now in Supervisor Level 4 At the prompt, type: set interface inband Replace , and with the VLAN, IP address and net mask of the stack. 5 Press Enter to save the IP address and net mask. 6 At the prompt, type reset and press Enter to reset the stack. After the Reset, log in again as described above.

Installation and Setup

Cajun P332MF User’s Guide 27 7 At the prompt, type set ip route and replace and with the destination and gateway IP addresses. 8 Press Enter to save the destination and gateway IP addresses. Note: If there are any errors, the new configuration settings will not be saved. To save the new configuration settings, you must correct the errors by repeating the command. 9 At the prompt, type exit to exit the CLI session. 10 Insert the Cajun P330 stack into your network.

Cajun P332MF User’s Guide

29 Chapter 5 Cajun Campus CLI - Architecture, Access & Conventions This chapter describes the Cajun P330 CLI architecture and conventions, and provides instructions for accessing the Cajun P330 for configuration purposes. The configuration procedure involves establishing a Telnet session or a serial connection and then using the Cajun P330’s internal CLI. The CLI is command-line driven and does not have any menus. To activate a configuration option, you must type the desired command at the prompt and press Enter. You can also configure your Cajun P330 using the Cajun P330 Manager with its graphical user interface. For details, see the Cajun P330 Device Manager Appendix and the CajunView P330 Manager User Guide on the Management CD. CLI Architecture The P330 stack supports both Layer 2 switching and Layer 3 switching. The P333R CLI includes two CLI entities to support this functionality. • The Switch CLI entity is used to manage Layer 2 switching of the entire stack. The Switch CLI entity is identical to the CLI of a P330 Layer 2 modules. CLI commands for managing Layer 2 switching are described in Chapter 6. • The Router CLI entity is used to manage Layer 3 switching of a single module. The Router CLI entity exists only in P330R Layer 3 modules and supports different sets of commands depending on the device mode of the P333R module. If the P333R module is the Master of the stack, then the Switch CLI entity and the Router CLI entity co-exist on the same module. To switch between the entities, use the session command. Refer to Cajun P330 Sessions. Initial access to the stack can be established via a serial connection or a Telnet connection to any one of the entities.

Cajun Campus CLI - Architecture, Access & Conventions

30 Cajun P332MF User’s Guide Establishing a Serial Connection Perform the following steps to connect a terminal (physical or emulation) to the Cajun P330 Master Switch Console port for configuration of Stack or Router parameters: 1 Use the serial cable supplied to attach the RJ-45 console connector to any Console port of the Cajun P330 Master Switch. Connect the DB-9 connector to the serial (COM) port on your PC/terminal. 2 Ensure that the serial port settings on the terminal are 9600 baud, 8 bits, 1 stop bit and no parity. 3 When you see the “Welcome to Cajun P330” menu and are prompted for a Login Name, enter the default login. The default login is root. 4 When you are promoted for a password, enter the password root. 5 Now you can establish a connection to the Router or the Master switch (indicated when the SYS front panel LED is ON) using the Session commands (see Cajun P330 Sessions on Page 31 for details) and begin configuration of Stack or Router parameters. Establishing a Telnet Connection Perform the following steps to establish a Telnet connection to the Cajun P330 for configuration of Stack or Router parameters. You can Telnet either the Stack Master IP address or directly to one of the Router IP address: 1 Connect your station to the network. 2 Verify that you can communicate with the Cajun P330 using Ping to the IP of the Cajun P330. If there is no response using Ping, check the IP address and default gateway of both the Cajun P330 and the station Note: The Cajun P330 default IP address is 149.49.32.134 and default subnet mask is 255.255.255.0. 3 From the Microsoft Windows® taskbar of your PC click Start and then Run (or from the DOS prompt of your PC), then start the Telnet session by typing: telnet For example: telnet 149.49.32.134 4 If the IP Address in Telnet command is the IP address of the stack, then connection is established with the Switch CLI entity of the Master module. If you want to connect to the Router CLI entity, use the session command. If the IP address in the Telnet command is of the router, connection is established to the Router CLI entity in the router module.When you see the “Welcome to P330” menu and are prompted for a Login Name, enter the default name root 5 When you are prompted for a password, enter the password root in lower

Cajun Campus CLI - Architecture, Access & Conventions

Cajun P332MF User’s Guide 31 case letters (do NOT use uppercase letters). The prompt will appear when you have established communications with the Cajun P330. Command Line Prompt When you start the CLI, the initial prompt shows the number of the Master module in the Cajun P330 stack. For example, if the stack Master is Module 5, counting from the bottom up, then the prompt is: Cajun_P330-5> In this document the Module number in the prompt is generic and is represented by “N”. If you wish to open a session with a Cajun P333R routing module in the stack or reopen a session with the Master module, use the session command (see below). The command prompt is not hierarchical in structure. If you wish to use several commands, each beginning with the same keyword, you must retype all parts of the command each time. For example, if after you want to set the system contact and the system name you must type both set system contact and set system name. However, you can use command abbreviations – see page 34. Cajun P330 Sessions You can use sessions to switch between P330 modules or to switch between Layer 2 and Layer 3 commands in the P333R CLI. To switch between P330 modules use the command: session [] The is the number of the module in the stack, counting from the bottom up. The can be either switch or router. When Module Number is not specified, the command switches between the modes in the local module. Use switch mode to configure layer 2 and EZ2route commands. Use router mode to configure routing commands. Examples: To configure router parameters in the module that you are currently logged into, type the following command: session router To configure the switch parameters, on module 6, type the command: session 6 switch Note: When you use the session command the security level stays the same.

Cajun Campus CLI - Architecture, Access & Conventions

32 Cajun P332MF User’s Guide Security Levels There are four security access levels – User, Privileged, Configure and Supervisor. • The User level is a general access level used to show system parameter values. • The Privileged level is used by site personnel to access stack configuration options. • The Configure level is used by site personnel for Layer 3 configuration. • The Supervisor level is used to define user names, passwords, and access levels of up to 10 local users. A login name and password are always required to access the CLI and gain access to the commands. The login names and passwords, and security levels are established using the username command (see page 95). Switching between the entities does not effect the security level since security levels are established specifically for each user. For example, if the operator with a privileged security level in the Switch entity switches to the Router entity the privileged security level is retained. Entering the Supervisor Level The Supervisor level is the level in which you first enter Cajun Campus CLI and establish user names for up to 10 local users. When you enter the Supervisor level, you are asked for a Login name. Type root as the Login name and the default password root (in lowercase letters): Welcome to Cajun P330 Login: root Password:**** Password accepted. Cajun_P330-N(super)# Defining new users Define new users and access levels using the username command in Supervisor Level. (see page 95). Exiting the Supervisor Level To exit the Supervisor level, type the command exit.

Cajun Campus CLI - Architecture, Access & Conventions

Cajun P332MF User’s Guide 33 Entering the CLI To enter the CLI, enter your username and password. Your access level is indicated in the prompt as follows: The User level prompt is shown below: Cajun_P330-N> The Privileged level prompt is shown below: Cajun_P330-N# The Configure level prompt for Layer 3 configuration is shown below: Cajun_P330-N(configure)# The Supervisor level prompt is shown below: Cajun_P330-N(super)# Entering the Technician Level This level is can only be accessed from the Privileged and Supervisor levels not from the User level. This feature is not documented and is for use by Lucent Technical Support only. Conventions Used The following conventions are used in this chapter to convey instructions and information: • Mandatory keywords are in boldface. • Variables that you supply are in pointed brackets <>. • Optional keywords are in square brackets []. • Alternative but mandatory keywords are grouped in braces {} and separated by a vertical bar |. • If you enter an alphanumeric string of two words or more, enclose the string in inverted commas. • Information displayed on screen is displayed in text font.

Cajun Campus CLI - Architecture, Access & Conventions

34 Cajun P332MF User’s Guide Navigation, Cursor Movement and Shortcuts The CLI contains a simple text editor with these functions: Getting Help On-line help may be obtained at any time by typing a question mark (?), or the word help on the command line or by pressing the F1 key. To obtain help for a specific command, type the command followed by a space and a question mark. Example: Cajun_P330-N(super)# show? Command Syntax Commands are not case-sensitive. That is, uppercase and lowercase characters may be interchanged freely. Command Abbreviations All commands and parameters in the CLI can be truncated to an abbreviation of any length, as long as the abbreviation is not ambiguous. For example, version can be abbreviated ver. For ambiguous commands, type the beginning letters on the command line and then use the Tab key to toggle through all the possible commands beginning with these letters. Table 5.1 Navigation, Cursor Movement and Shortcuts Keyboard Functions Backspace Deletes the previous character Up arrow/Down arrow Scrolls back and forward through the command history buffer Left arrow/Right arrow Moves the cursor left or right Tab Completes the abbreviated command. Type the minimum number of characters unique to the command. An exception is the Reset System command which you must type in full. Enter Executes a single-line command “ “ If you type a name with quotation marks, the marks are ignored.

Cajun Campus CLI - Architecture, Access & Conventions

Cajun P332MF User’s Guide 35 Universal Commands Universal commands are commands that can be issued anywhere in the hierarchical tree. Top and Up commands The Up command moves you up to the next highest level in the CLI command hierarchy. The Top command moves you to the highest level. Retstatus command Use the retstatus command to show whether the last CLI command you performed was successful. It displays the return status of the previous command. The syntax for this command is: retstatus Output Example: Cajun_P330-N# set port negotiation 2/4 disable Link negotiation protocol disabled on port 2/4. Cajun_P330-N# retstatus Succeeded Tree command The tree command displays the commands that are available at your current location in the CLI hierarchy. The syntax for this command is: tree

Cajun P332MF User’s Guide

37 Chapter 6 Cajun Campus CLI – Layer 2 This chapter provides instructions for the configuration of your Cajun P330 using the text-based Cajun Campus Command Line Interface (CLI or Terminal Emulation). You can also configure your Cajun P330 using the Cajun P330 Manager with its graphical user interface (see Appendix A). The configuration procedure involves establishing a Telnet session or a serial connection and then using the Cajun P330’s internal CLI. See Chapter 5 for instructions on how to establish a Telnet session or serial connection, and for a description of CLI conventions. The CLI is command-line driven and does not have any menus. To activate a configuration option, you must type the desired command at the prompt and press Enter. User Level Commands This section describes all commands that are available from the User level. Following is a table of the User Level commands and command groups (all commands are also available at the higher levels). • session Opens a session to another Cajun P330 module or X330 ATM Access module Page 38 • terminal width Display or set the width of the terminal display Page 38 • terminal length Display or set the length of the terminal display Page 38 • clear screen Clears the current terminal display Page 39 • show1 1 This command corresponds to a group of commands and is shown in a separate Table on Page 39 Shows the current switch parameters Page 39 • ping Sends ICMP echo request packets to another node on the network Page 39 • dir Show files in the System Page 60

Cajun Campus CLI – Layer 2

38 Cajun P332MF User’s Guide Session Command Use the session command to open a session with a specific entity in a module of the stack. For example, you can open a session with the Routing entity of a Cajun P333R module in the stack, or with an the X330 ATM module entity plugged into a specific module. The syntax for this command is: session [ [switch|router|atm]] Note: Layer 2 commands are only available if you open a switch session with the Master module. Router commands are described in the Cajun P333R User’s Guide. Example: Cajun_P330-N# session 2 router Note: When you use the session command the security level stays the same. Terminal Commands Use the terminal width and terminal length commands to set the width and length of the terminal display in characters. The syntax for this command is: terminal {width|length} [] mod_num (optional) Number of the module. If you do not specify this parameter, you will get the default entity of the stack (Layer 2 session to the Master) switch|router|atm (optional) The entity to which you want to open a session If you do not specify this parameter, you will get the default entity of the specific module: switch - Layer 2 entity of the module (see Note below) router - Cajun P333R Routing entity atm - X330 Access module ATM entity

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 39 Clear screen Command The clear screen command clears the current terminal display. The syntax for this command is: clear screen Ping Command Use the ping command to send ICMP echo request packets to another node on the network. The syntax for this command is: ping [host[number]] Note: You can use this command via the Master module only. Example: To ping the IP number 149.49.48.1 ten times: Cajun_P330-N> ping 149.49.48.1 10 ping 149.49.48.1 10: 56 databytes 64 bytes from 149.49.48.1: icmp_seq=0. time=8 ms Show Commands Summary Table Following is a table of the show commands: host Host IP address/Internet address of route destination. If missing then the last host IP is used. number Number of packets to send. If missing then the last number is used • show time Show current time Page 41 • show timezone Show the current timezone offset Page 41 • show ntp Display the current Network Time Protocol (NTP) status and parameters Page 41 • show ip route Show IP routing table entries Page 42 • show image version Show the image version Page 42 • show snmp Show SNMP community strings Page 43 • show snmp retries Show SNMP retries number Page 43 • show snmp timeout Show SNMP timeout Page 43

Cajun Campus CLI – Layer 2

40 Cajun P332MF User’s Guide • show timeout Show CLI timeout setting Page 43 • show interface Show the interfaces of the device Page 44 • show port Show settings and status for all ports Page 45 • show port trap Show port trap Page 46 • show port channel Show port channel Page 46 • show port redundancy Display information on redundancy schemes Page 47 • show port mirror Show mirroring info Page 47 • show module Show module Page 47 • show flowcontrol Show flowcontrol Page 48 • show cam Show CAM Page 49 • show trunk Show trunk (VLAN tagging) Page 50 • show spantree Show Spanning Tree Protocol (STP) setting Page 51 • show autopartition Shows the autopartition settings. Page 53 • show license Shows the license Page 53 • show system Show system parameters Page 53 • show internal buffering Show current internal buffering capacity Page 54 • show intermodule port redundancy Show the stack’s intermodule redundancy Page 54 • show rmon statistics Show the traffic statistics of an interface Page 55 • show rmon history Show the existing history entries Page 55 • show rmon alarm Shows the existing alarm entries Page 56 • show rmon event Shows the existing event entries Page 56 • show tftp upload/ download status Show status of the TFTP upload/ download configuration per module Page 57 • show tftp download software status Show status of the TFTP software download of the Device Manager software to the module Page 57 • show web aux-files-url Show the location (url/directory) of the Cajun P330 Device Manager Help files Page 57

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 41 Show time Command Use the show time command to display the current stack time. The syntax for this command is: show time Example: Cajun_P330-N> show time 10:32:34 27 JAN 2000 GMT Show timezone Command Use the show timezone command to display the current stack timezone. The syntax for this command is: show timezone Example: Cajun_P330-N> show timezone Timezone set to 'GMT', offset from UTC is 0 hours Show ntp Command Use the show ntp command to display the address of the Network Time Protocol (NTP) server in addition to other time related status information. The syntax for this command is: show ntp • show intelligent multicast Shows the status IP multicast filtering application Page 58 • show intelligent multicast hardware support Shows whether the connected unit’s hardware supports IP multicast filtering Page 58 • show secure mac Shows the secure MAC addresses of a port Page 59 • show security mode Displays the status of the MAC security feature (enabled/disabled) Page 59 • show port security Lists the security mode of the ports of a module or stack. Page 59

Cajun Campus CLI – Layer 2

42 Cajun P332MF User’s Guide Example: Cajun_P330-N> show ntp Current time: 10:37:04 27 JAN 2000 GMT Timezone set to 'GMT', offset from UTC is 0 hours NTP-Server: 149.49.52.134 Show ip route Command Use the show ip route command to display IP routing table entries. The syntax for this command is: show ip route Example: Cajun_P330-N> show ip route Show image version Command Use the show image version command to display the software version of the image on both memory banks of a specified module. The syntax for this command is: show image version [] If no module number is specified, the image version of the all modules will be displayed. Example: Cajun_P330-N> show image version 1 Destination Gateway ----------- ----------- 149.49.1.1 172.20.22.201 190.20.0.0 172.20.22.202 172.20.0.0 172.20.22.96 Mod Module-Type Bank Version ----- ---------------- ----- ------- 1 12x100Base-F (MT-RJ) with optional expansion slot A 3.0.4 1 12x100Base-F (MT-RJ) with optional expansion slot B 3.0.4

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 43 Show snmp Command Use the show snmp command to display SNMP information. The syntax for this command is: show snmp Example: Cajun_P330-N> show snmp Authentication trap disabled Community-Access Community-String ---------------- ---------------- read-only public read-write public trap public Trap-Rec-Address Traps Enabled ---------------- ---------------- 1.1.1.1 config fault etc... Show snmp retries Command Use the show snmp retries command to display the number of retries initiated by the Device Manager application when it tries to send SNMP messages to the device. The syntax for this command is: show snmp retries Example: Cajun_P330-N> show snmp retries the SNMP Retries Number is 3 Show snmp timeout Command Use the show snmp timeout command to display the default SNMP timeout in seconds. This command is useful for access using the Device Manager. The syntax for this command is: show snmp timeout

Cajun Campus CLI – Layer 2

44 Cajun P332MF User’s Guide Example: Cajun_P330-N> show snmp timeout the SNMP Timeout is 2000 Show timeout Command Use the show timeout command to display the amount of time the CLI can remain idle before timing out in minutes. If the result is 0, there is no timeout limit. The syntax for this command is: show timeout Example: Cajun_P330-N> show timeout CLI timeout is 10 minutes Show interface Command Use the show interface command to display information on network interfaces. The syntax for this command is: show interface Example: To display the interface: Cajun_P330-N> show interface Interface Name VLAN IP address Netmask -------------- ---- --------------- --------------- inband 1 149.49.42.252 255.255.255.0 ppp 1 0.0.0.0 0.0.0.0

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 45 Show port Command Use the show port command to display port status. The syntax for this command is: show port [[/]] Example: To display the status for port 4 on module 3: Cajun_P330-N> show port 3/4 Port Name Status Vlan Level Neg Dup. Spd. Type ------ --------------- --------- ---- ------ ------- ---- ---- ------------- 3/4 John connected 1 normal enable half 10M 10/100Base-Tx Show Port Output Fields mod_num (Optional) Number of the module. If you do not specify a number, the ports on all modules are shown. port_num (Optional) Number of the port on the module. If you do not specify a number, all the ports on the module are shown. You can also specify a range of ports separated by a dash, e.g. 5-13 for ports 5 to 13. Field Description Port Module and port number Name The name you assigned to the port Status Status of the port (connected, faulty, disabled) VLAN VLAN ID of the port Level Priority level of the port (normal or high) Neg The autonegotiation status of the port (enable, disable) Duplex Duplex setting for the port (fdx, hdx) Speed Speed setting for the port (10, 100). Type Port type, for example, 10BaseT, 10BaseFL, 100BaseTX, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX

Cajun Campus CLI – Layer 2

46 Cajun P332MF User’s Guide Show port trap Command Use the show port trap command to display information on SNMP generic link up/down traps sent for a specific port. The syntax for this command is: show port trap [[/]] Example: Cajun_P330-N> show port trap 1/1 Port 1/1 up/down trap is disabled Show port channel Command Use the show port channel command to display Link Agreggation Group (LAG) information for a specific module or port. The syntax for this command is: show port channel [[/]] Example: show port channel 1 Port Channel Status Channel Name ------ --------------- -------------------------------- 1/1 off 1/2 off 1/3 on server1 1/4 on server1 1/13 off 1/14 off 1/15 off 1/16 off ------ --------------- -------------------------------- 1/5 off etc... Note: Ports are listed and grouped according to the possible LAG membership.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 47 Show port redundancy Command Use the show port redundancy command to display information about all redundancy schemes defined for this stack. The syntax for this command is: show port redundancy Example: Cajun_P330-N> show port redundancy Redundancy Name Primary Port Secondary Port Status ----------------- -------------- ---------------- -------- uplink 1/7 2/12 enable Show port mirror Command Use the show port mirror command to display mirroring information for the stack. The syntax for this command is: show port mirror [[/]] Example: Cajun_P330-N> show port mirror port mirroring Mirroring both Rx and Tx packets from port 1/2 to port 1/4 is enabled Show module Command Use the show module command to display module status and information. For each module with an expansion sub-module installed, both module and sub- module type and information are shown. The syntax for this command is: show module [] mod_num (Optional) Number of the module. If you do not specify a number, all modules are shown.

Cajun Campus CLI – Layer 2

48 Cajun P332MF User’s Guide Example: Cajun_P330-N> show module Mod Type Ports Serial-Num C/S Sw Boot Ver --- ---------- ----- ---------- --- ----- -------- 1 CajunP332MF 12 4171661 1.1 2.0.3 0.0.0 Mod Sub-Type Sub-Ports Sub-C/S --- ------------------- --------- ------- 1 CajunX330S2 2 1.1 Output Fields Show flowcontrol Command Use the show port flowcontrol command to display per-port status information related to flow control. The syntax for this command is: show flowcontrol [[/]] Example: Cajun_P330-N> show flowcontrol 3/2 Port Send-Flowcontrol Receive-Flowcontrol Admin Oper Admin Oper ------ ----- ---- ----- ---- 3/2 off off off off Field Description Mod Module number Module-Type/Sub-Type Module Type/Expansion sub-module type Ports/Sub-Ports Number of ports on the module/Expansion sub- module. Serial-Num Serial number of the module C/S / Sub-C/S (Hardware) Configuration Symbol of the module/ Expansion sub-module Sw Software version loaded into the module Boot Ver Boot software version loaded into the module

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 49 Output Fields Show cam Commands Use the show cam commands to display the CAM table entries for a specific port or MAC Address. The syntax for this command is: show cam [[/]] and show cam mac Field Description Port Module and port number Send- Flowcontrol- Admin Send flow-control administration. Possible settings: • ON indicates that the local port is allowed to send flow control frames to the far end. • OFF indicates that the local port is not allowed to send flow control frames to the far end. Send- Flowcontrol- Oper Send flow-control operation mode. Possible modes: • ON indicates that the local port will send flow control frames to the far end. • OFF indicates that the local port will not send flow control frames to the far end. Receive- Flowcontrol- Admin Receive flow-control administration. Possible settings: • ON indicates that the local port will act upon flow control indications if received from the far end. • OFF indicates that the local port will discard flow control frames if received from the far end. Receive- Flowcontrol- Oper Receive flow-control operation mode. Possible modes: • ON indicates that the local port will act upon flow control indications received from the far end. • OFF indicates that the local port will discard flow control frames received from the far end.

Cajun Campus CLI – Layer 2

50 Cajun P332MF User’s Guide Example: Cajun_P330-N> show cam 1/1 Dest MAC/Route Dest Destination Ports ------------------- ----------------- 00-40-0d-59-03-78 1/1 00-d0-79-0a-0a-da 1/1 00-40-0d-43-1e-e9 1/1 etc... Cajun_P330-N> show cam mac 00-40-0d-88-06-c8 Dest MAC/Route Dest Destination Ports ------------------- ----------------- 00-40-0d-88-06-c8 1/1 Total Matching CAM Entries Displayed = 1 Show trunk Command Use the show trunk command to display VLAN tagging information of the ports. The syntax for this command is: show trunk [[/]] Example: Cajun_P330-N> show trunk 1/22 show trunk 1/22 Port Mode Native vlan Vlans allowed on trunk ------ ----- ----------- ---------------------- 1/22 dot1q 1 1-3071

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 51 Following are the show trunk command output fields: Show spantree Command Use the show spantree command to display spanning-tree information. The syntax for this command is: show spantree [[/]] Example: Cajun_P330-N> show spantree Spanning tree enabled Designated Root: 00-40-0d-88-06-c8 Designated Root Priority: 32768 Designated Root Cost: 20 Designated Root Port: 1/1 Root Max Age: 20 Hello Time: 2 Bridge ID MAC ADDR: 00-40-0d-92-04-b4 Bridge ID priority: 32768 Port State Cost Priority ------ ------------- ---------- ------------ 1 /1 Forwarding 20 128 1 /2 not-connected 20 128 1 /3 LAG-member 20 128 1 /4 LAG-member 20 128 1 /5 not-connected 20 128 Field Description Port Module and port number(s) Mode Tag status of the port (ON - dot1Q tagging mode, OFF - clear mode). Native VLAN Number of the Port VLAN ID (the VLAN to which received untagged traffic will be assigned). If the Port is in “clear mode” only frames of this VLAN will be transmitted. VLANs allowed on trunk Range of values allowed for the Native VLAN (1 to 3071)

Cajun Campus CLI – Layer 2

52 Cajun P332MF User’s Guide 1 /6 not-connected 20 128 etc... Output Fields: Field Description Spanning tree Status of whether Spanning-Tree Protocol is enabled or disabled. Designated Root MAC address of the designated spanning-tree root bridge Designated Root Priority Priority of the designated root bridge Designated Root Cost Total path cost to reach the root Designated Root Port Port through which the root bridge can be reached (shown only on nonroot bridges). Root Max Age Amount of time a BPDU packet should be considered valid. Hello Time Number of times the root bridge sends BPDUs. Bridge ID MAC ADDR Bridge MAC address used in the sent BPDUs. Bridge ID Priority Bridge priority Port Port number State Spanning-tree port state (disabled, inactive, not-connected, blocking, listening, learning, forwarding, bridging, or type- pvid-inconsistent). Cost Cost associated with the port. Priority Priority associated with the port.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 53 Show autopartition Command Use the show autopartition command to display the automatic partition. The syntax for this command is: show autopartition Example: Cajun_P330-N> show autopartition Auto-partition is enabled. Show license Command Use the show license command to display a module license. The syntax for this command is: show license [module] module module number Example: Cajun_P330-N> show license 1 Cajun_P330-N> Module 1 License: Application License Key ----------------- ----------------------------- SMON 0000 0000 0000 0000 0000 0000 Show system Command Use the show system command to display the up time, system name, location, and contact person. The syntax for this command is: show system Example: Cajun_P330-N> show system Uptime d,h:m:s ------------------------ 0,2:40:55 System Name System Location System Contact --------------------- ------------------------- ------------------------- P330T_version_2.0.3 Alpha LAB Ygdal Naouri

Cajun Campus CLI – Layer 2

54 Cajun P332MF User’s Guide Switch MAC address ------------------ 00 40 0d 8a 04 b4 Module Main Backup Main Backup PS Number Power Supply Power Supply Fans Fans ------ ------------ ------------ ------------ ------------ 1 active n/a ok n/a Show internal buffering Command This shows the size options (Maximum, Minimum, or Dynamic) of the Receive (Rx) buffer allocated to each port of the specified module. The syntax for this command is: show internal buffering [] Example: Cajun_P330-N> show internal buffering 1 Module Internal Buffer ------ --------------- 1 dyn Show intermodule port redundancy Command Use the show intermodule redundancy command to to display the intermodule redundancy entry defined for the stack. The syntax for this command is: show intermodule port redundancy Example: Cajun_P330-N> show intermodule port redundancy Primary-Port : 1/1 Primary-Port status : Disable Secondary-Port : 1/2 Secondary-Port status : Disable

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 55 RMON Tools Following are a series of RMON commands, however we recommend using the Cajun P330 Device Manager. Show rmon statistics Command This command shows the RMON statistics counters for a certain interface number according to the MIB-2 interface table numbering scheme. The syntax for this command is: show rmon statistics Example: Cajun_P330-N> show rmon statistics 1026 statistics Interface 1026 is active, owned by Monitor Monitors ifEntry.1.1026 which has Received 26375085 octets, 222536 packets, 154821 broadcast and 53909 multicast packets, 0 undersize and 0 oversize packets, 0 fragments and 0 jabbers, 1 CRC alignment errors and 0 collisions, # of dropped packet events (due to a lack of resources): 0 # of packets received of length (in octets): 64:94530, 65-127:85124, 128-255:25896, 256-511:10440, 512-1023:6057, 1024-1518:489, Show rmon history Command This command shows the most recent RMON history log for a given History Index. The history index is defined using the rmon history command on Page 89 or using an RMON management tool. The syntax for this command is: show rmon history [] Example: Cajun_P330-N> show rmon history 1026 history Entry 1026 is active, owned by amir

Cajun Campus CLI – Layer 2

56 Cajun P332MF User’s Guide Monitors ifEntry.1.1026 every 30 seconds Requested # of time intervals, ie buckets, is 20 Granted # of time intervals, ie buckets, is 20 Sample # 1 began measuring at 2:53:9 Received 62545 octets, 642 packets, 391 broadcast and 145 multicast packets, 0 undersize and 0 oversize packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions, # of dropped packet events (due to a lack of resources): 0 Network utilization is estimated at 0 Show rmon alarm Command This command shows the parameters set for a specific alarm entry that was set using the rmon alarm command on Page 90 or using the Cajun P330 Device Manager. The syntax for this command is: show rmon alarm [] Example: Cajun_P330-N> show rmon alarm 1026 alarm alarm 1026 is active, owned by amir Monitors ifEntry.1.1026 every 60 seconds Taking delta samples, last value was 1712 Rising threshold is 10000, assigned to event # 1054 Falling threshold is 10, assigned to event # 1054 On startup enable rising or_falling alarms Show rmon event Command This command shows the parameters of an Event entry defined by the rmon event command on Page 91 or using the Cajun P330 Device Manager. The syntax for this command is: show rmon event [] Example: Cajun_P330-N> show rmon event 1054 event

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 57 Event 1054 is active, owned by amir Description is event for monitoring amir's co Event firing causes log and trap to community public,last fired 0:0:0 Show tftp download/upload status Command Use the show tftp download status and show tftp upload status commands to display the status of the current TFTP configuration file copy process into/from the device. The syntax for this command is: show tftp {download|upload} status [] Example: Cajun_P330-N> show tftp upload status 1 Module : 1 Source file : stack-config Destination file : c:\conf.cfg Host : 149.49.36.200 Running state : Executing Failure display : (null) Last warning : No-warning Show tftp download software status Command Use the show tftp download software status commands to display the status of the current TFTP Device Manager S/W (Embedded Web) download process into the device. The syntax for this command is: show tftp download software status [] Show web aux-files-url Command Use the show web aux-files-url command to display the URL/Directory from where the Cajun P330 can access the Device Management auxiliary files (for example help files). The syntax for this command is: show web aux-files-url

Cajun Campus CLI – Layer 2

58 Cajun P332MF User’s Guide Show intelligent-multicast command Use the show intelligent-multicast Command to display the intelligent multicast configuration. The syntax for this command is: show intelligent-multicast Example: Cajun_P330-N> show intelligent-multicast Intelligent-multicast configuration: ------------------------------------ intelligent-multicast state --------------------- Disabled Intelligent-multicast client-port-pruning time --- 600[Sec] Intelligent-multicast router-port-pruning time ---1800[Sec] intelligent-multicast group-filtering-delay time - 10[Sec] Intelligent-multicast HW configuration: # Module Sub-Module Cascade ------- ---------- -------- 1 No IPMc Support Not Installed No IPMc Support Show intelligent-multicast hardware-support Command Use the show intelligent-multicast hardware-support command to display the intelligent multicast hardware support configuration. The syntax for this command is: show intelligent-multicast hardware-support Example: Cajun_P330-N> show intelligent-multicast hardware support Intelligent-multicast HW configuration: # Module Sub-Module Cascade ------- ---------- -------- 1 No IPMc SupportNot Installed No IPMc Support

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 59 Show secure mac Command Use the show secure mac command to display the secure MAC addresses of a port from the sub-agent CLI. This command is accessed only through connection to a particular module. The syntax for this command is: show secure mac port / Example: Cajun_P330-N> show secure mac port 1 Port Secure-Src-Addrs ------ ----------------- 1/17 00-50-04-07-6a-fa 01-02-03-04-05-06 Show security mode Command Use the show security mode command to display the status of the MAC security feature. The syntax for this command is: show security mode Example: Cajun_P330-N> show security mode Security mode enabled. Show port security Command Use the show port security command to list the security mode of the ports of a module or stack. When no port number is specified, this command displays all the secured ports in the stack. The syntax for this command is: show port security [[/]] Example: Cajun_P330-N> show port security 1 Port 1/1 port security disabled. Port 1/2 port security disabled. Port 1/3 port security disabled.

Cajun Campus CLI – Layer 2

60 Cajun P332MF User’s Guide Port 1/4 port security disabled. Port 1/5 port security disabled. Port 1/6 port security disabled. Port 1/7 port security disabled. Port 1/8 port security disabled. Port 1/9 port security disabled. Port 1/10 port security disabled. Port 1/11 port security disabled. etc. Dir Command The dir command is used to show the file types that have been downloaded to the module. The syntax for this command is: dir [] Example: Cajun_P330-N> dir M# file ver num file type file location file description -- ---- -------- ---------- ------------- ---------------- 1 module-config N/A Running Conf Ram Module Configuration 1 stack-config N/A Running Conf Ram Stack Configuration 1 EW_Archive N/A SW Web Image Nv-Ram WEB Download Note: The message “Operation Failed” appears when the dir command is entered for the lowest module on a stack. Output Fields: Field Description M# Module number

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 61 Note: If the N/A is displayed for the EW_Archive file this means that the Device Manager S/W is not loaded correctly. Download the Device Manager S/W again. file There are several files loaded into modules memory: • module-config – file which contains the configuration settings made to this module. • stack-config – file which contains the configuration settings made at the stack level (for example IP address of the stack) • EW_Archive – file which contains the Device Manager (Embedded Web) software. ver num S/W Version number – relevant only for the Device Management S/W file type There are several file types: • Running Conf – the configuration currently in use. This is also the startup configuration in the Cajun P332MF. • SW Web Image – Device Manager S/W archive file file location Type of internal memory into which the file is loaded file description Description of the file

Cajun Campus CLI – Layer 2

62 Cajun P332MF User’s Guide Privileged Level Commands Following is a table of the Privileged Level commands. This level includes all the commands from the User Level described above (see the User Level Commands Section for a description of these common commands). • no hostname Return the prompt to its default Page 63 • no rmon history Deletes an existing history entry Page 63 • no rmon alarm Deletes an existing alarm entry Page 63 • no rmon event Deletes an existing event entry Page 63 • hostname Displays or sets a new prompt Page 64 • clear1 Clears current settings (group of commands) Page 64 • set2 Set the module parameters (group of commands) Page 67 • sync time Synchronizes the time between modules Page 85 • get time Gets the time from the time server Page 88 • reset Restarts the system or a module Page 88 • nvram initialize Initialize the NVRAM to its factory defaults Page 89 • configure Currently not used in the Layer 2 CLI. Page 89 • tech Enter Technician level – Lucent personnel only – • rmon history Creates a history entry Page 89 • rmon alarm Creates an alarm entry Page 90 • rmon event Creates an event entry Page 91 • copy stack- config tftp Upload stack configuration to a file (using tftp). The file must exist before you Upload. Page 91 • copy module- config tftp Upload module configuration to a file (using tftp). The file must exist before you Upload. Page 92 • copy tftp stack-config Download a stack configuration file (using TFTP) into the device Page 93

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 63 No hostname Command Use the no hostname command to return the CLI prompt to its default. The syntax for this command is: no hostname No rmon history Command Use the no rmon history command to delete an existing RMON history entry. The syntax for this command is: no rmon history No rmon alarm Command Use the no rmon alarm command to delete an existing RMON alarm entry. The syntax for this command is: no rmon alarm No rmon event Command Use the no rmon event command to delete an existing RMON event entry. The syntax for this command is: no rmon event • copy tftp module-config Download a module configuration file (using TFTP) Page 93 • copy tftp EW_Archive Download the Device Manager S/W (Embedded Web Archive file), using TFTP, into the device Page 94 • copy tftp SW_image Updates the software image and device manager application of a designated module Page 94 1 The clear command corresponds to a group of commands and is shown in a separate Table on Page 64. 2 The set command corresponds to a group of commands and is shown in a separate Table on Page 67.

Cajun Campus CLI – Layer 2

64 Cajun P332MF User’s Guide Hostname Command Use the hostname command to change the Command Line Interface (CLI) prompt. The current module number always appears at the end of the prompt. The syntax for this command is: hostname [] Clear Commands Summary Table Following is a Table of the Privileged Level clear commands. Clear timezone Command Returns the timezone to its default, Coordinated Universal Time (UTC) Clear ip route Command Use the clear ip route command to delete IP routing table entries. The syntax for this command is: clear ip route hostname_string none – displays current hostname string – the string to be used as the hostname (up to 20 characters). • clear timezone Returns the timezone to its default, UTC Page 64 • clear ip route Clear IP routing table entries Page 64 • clear snmp trap Clear SNMP trap on the system Page 65 • clear vlan Clears VLAN entries Page 65 • clear cam Clears all the CAM entries Page 66 • clear log Clears the Log entries of a module Page 66 • clear port mirror Cancel port mirroring Page 66 • clear secure mac Clear a MAC address Page 66 destination IP address of the network, or specific host to be added gateway IP address of the router.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 65 Example: To delete the route table entries using the clear ip route command: Cajun_P330-N# clear ip route 134.12.3.0 192.1.1.1 Route deleted. Clear snmp trap Command Use the clear snmp trap command to clear an entry from the SNMP trap receiver table. The syntax for this command is: clear snmp trap {|all} Example: Cajun_P330-N# clear snmp trap 192.122.173.82 SNMP trap receiver deleted. Clear vlan Command Use the clear vlan command to delete an existing VLAN and return ports from this VLAN to the default VLAN #1. When you clear a VLAN, all ports assigned to that VLAN are assigned to the default VLAN #1. The syntax for this command is: clear vlan [VLAN_num] Example: This example shows how you can delete an existing VLAN (VLAN 4) from a management domain: Cajun_P330-N# clear vlan 4 This command will assign all ports on VLAN 4 to their default in the entire management domain Do you want to continue (y/n) [n]? y VLAN 4 deletion successful rcvr_addr IP address or IP alias of the trap receiver (the SNMP management station) to clear. all Keyword that specifies every entry in the SNMP trap receiver table VLAN_num Number of the VLAN (range is 1to 3071).

Cajun Campus CLI – Layer 2

66 Cajun P332MF User’s Guide Clear cam Command Use the clear cam command to delete all entries from the CAM table. The syntax for this command is: clear cam Example: Cajun_P330-N# clear cam CAM table entry cleared. Clear log Command Use the clear log command to delete the Log file of a module. The syntax for this command is: clear log [] Clear port mirror Command Use the clear port mirror command to cancel port mirroring. The syntax for this command is: clear port mirror /// Example: Cajun_P330-N# clear port mirror 1/2/1/4 this command will delete the port mirror entry - do you want to continue (Y/N)? y Mirroring packets from port 1/2 to port 1/4 is cleared Clear secure mac Command Use the clear secure mac command to remove a MAC address from the CAM table of a secured port. The syntax for this command is: clear secure mac port / Example: Cajun_P330-N> clear secure mac 1-2-3-4-5 port 1/17 01-02-03-04-05 cleared from secure address list for port 1/17

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 67 Set Commands Summary Table Following is a Table of the Privileged Level set commands. • set logout Set the number of minutes before an inactive CLI session automatically logs out Page 69 • set timezone Set the timezone for the system Page 70 • set ntp server Set the NTP server address Page 70 • set ip route Add IP addresses to the IP routing table Page 70 • set snmp trap Set the SNMP trap of the system or add/ delete an entry into/from the SNMP trap receiver table Page 71 • set snmp trap auth Enable/Disable the SNMP authentication trap Page 72 • set snmp retries Set the number of SNMP retries Page 72 • set snmp timeout Set the SNMP timeout Page 73 • set system location Set the system location Page 73 • set system name Set the system name Page 73 • set system contact Set the system contact person Page 73 • set interface Configure the management interface of the device Page 74 • set port level Set the priority level of a port Page 74 • set port negotiation Set the autonegotiation mode of a port Page 75 • set port enable Administratively enable a port Page 75 • set port disable Administratively disable a port Page 75 • set port speed Set the speed for a 10/100 port Page 76 • set port duplex Set the duplex mode of a port Page 76 • set port name Assign a name to a port Page 76 • set port trap Enable/Disable the SNMP up/down link traps sent for port Page 77

Cajun Campus CLI – Layer 2

68 Cajun P332MF User’s Guide • set port vlan Assign the Port VLAN ID (PVID) Page 77 • set port channel Define a LAG interface Page 78 • set port redundancy on/off Define/Delete a link redundancy entry Page 78 • set port redundancy Enables/Disables all the defined link redundancy schemes Page 79 • set port mirror Set a port mirroring source-destination pair in the stack Page 79 • set inband vlan Set the management VLAN ID Page 80 • set flowcontrol Set the flow control mode of a port Page 80 • set auto-negotiation-flowcontrol-advertisement Set the flowcontrol advertising capabilities of a Gigabit port Page 81 • set trunk Set the tagging mode of a port Page 82 • set spantree Enable/Disable Spanning Tree Protocol (STP) Page 83 • set spantree priority Set the STP Bridge priority level Page 83 • set autopartition To enable or disable autopartitioning for all the ports in half-duplex mode Page 83 • set license Enter a license number for the stack Page 83 • set internal buffering Set internal buffering capacity to maximum/minimum Page 84 • set intermodule port redundancy Defines the stack’s unique fast redundancy scheme Page 84 • set web aux-files-url Set the location (url/directory) of the Cajun P330 Device Manager Help files Page 85 • set intelligent- multicast Enables or disables the IP multicast filtering application Page 85 • set intelligent- multicast client- port-pruning time Sets the aging time for client ports Page 85

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 69 Set logout Command The set logout command is used to set the number of minutes until the system automatically disconnects an idle session. The syntax for this command is: set logout Example: To set the number of minutes until the system disconnects an idle session automatically: Cajun_P330-N# set logout 20 Sessions will be automatically logged out after 20 minutes of idle time. To disable the automatic disconnection of idle sessions: Cajun_P330-N# set logout 0 Sessions will not be automatically logged out. • set intelligent- multicast router- port-pruning time Sets the aging time for router ports Page 86 • set intelligent- multicast group- filtering-delay time Sets the time delay before a filter is applied to a specific group Page 86 • set secure mac Adds a unicast MAC addres into the CAM table of a secured port Page 86 • set security mode Enables or disables the stack’s MAC security Page 87 • set port security Enables MAC security on a range of ports Page 87 timeout Number of minutes (0 to 999) until the system automatically disconnects an idle session. Setting the value to 0 disables the automatic disconnection of idle sessions (default is 15 minutes).

Cajun Campus CLI – Layer 2

70 Cajun P332MF User’s Guide Set timezone Command Use the set timezone command to assign a timezone name and set the time difference of your Cajun P330 relative to the Coordinated Universal Time (UTC/ GMT). The minutes paramater can only be set to 30. The syntax for this command is: set timezone [-][:30] Example: set timezone GMT -3:30 Timezone set to 'GMT', offset from UTC is -3:30 hours Set ntp server Command The set ntp server command is used to set the NTP server address. The syntax for this command is: set ntp server Set ip route Command Use the set ip route command to add IP addresses to the IP routing table. You can configure from one to ten (10) default gateways for a Cajun P330 stack. The syntax for this command is: set ip route ip IP address of the ntp server. destination IP address of the network, or specific host to be added gateway IP address of the router.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 71 Example: This example shows how to add a default route to the IP routing table: Cajun_P330-N# set ip route 149.49.42.54 149.49.42.200 destination = 149.49.42.54 gateway = 149.49.42.200 ROUTE NET TABLE destination gateway flags Refcnt Use Interface ------------------------------------------------------------------------ 149.49.42.0 149.49.42.205 1 1 3199 se0 127.1.1.0 127.1.1.1 1 8 7606 se1 ------------------------------------------------------------------------ ROUTE HOST TABLE destination gateway flags Refcnt Use Interface ------------------------------------------------------------------------ 127.0.0.1 127.0.0.1 5 2 131 lo0 149.49.42.54 149.49.42.200 7 0 0 se0 ------------------------------------------------------------------------ Set snmp trap Commands Use the set snmp trap commands to add an entry into the SNMP trap receiver table and to enable or disable the different SNMP traps for a specific receiver. First add the rcvr_addr and then enable/disable the different traps for it. The syntax for this command is: set snmp trap set snmp trap {enable|disable} {all|config|fault|...} enable Activate SNMP traps disable Deactivate SNMP traps all (Optional) Specify all trap types config (Optional) Specify the ConfigChange trap from the TRAP-MIB. fault (Optional) Specify the Fault trap from the TRAP-MIB. rcvr_addr IP address or IP alias of the system to receive SNMP traps

Cajun Campus CLI – Layer 2

72 Cajun P332MF User’s Guide Example: To enable SNMP ConfigChange traps to a specific manager: Cajun_P330-N# set snmp trap 192.122.173.42 enable config SNMP config change traps enabled. To enable all traps to a specific manager: Cajun_P330-N# set snmp trap 192.122.173.42 enable all All SNMP traps enabled. To disable SNMP config traps to a specific manager: Cajun_P330-N# set snmp trap 192.122.173.42 disable config SNMP config traps disabled. To add an entry in the SNMP trap receiver table with default: Cajun_P330-N# set snmp trap 192.122.173.42 SNMP trap receiver added. Set snmp trap auth Command Use the set snmp trap auth commands to enable/disable the sending of SNMP traps upon SNMP authentication failure. The syntax for this command is: set snmp trap {enable|disable} auth Example: Cajun_P330-N# set snmp trap enable auth Authentication trap enabled Set snmp retries Command Use the set snmp retries command to set the number of retries initiated by the Device Manager application when it tries to send SNMP messages to the device. The syntax for this command is: set snmp retries

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 73 Set snmp timeout Command Use the set snmp timeout command to set the SNMP timeout in seconds. This command is useful for access using the Device Manager. The syntax for this command is: set snmp timeout Set system location Command Use the set system location command to set the mib2 system location MIB variable. The syntax for this command is: set system location [] Set system name Command Use the set system name command to set mib2 system name MIB variable. The syntax for this command is: set system name [] Set system contact Command Use the set system contact command to set mib2 system contact MIB variable. The syntax for this command is: set system contact [] string Location name. The location name is cleared if this field is left blank. A string of 2 words or more must be type in quotation marks – e.g. “Operations Floor”. string System name. The system name is cleared if this field is left blank. A string of 2 words or more must be type in quotation marks – e.g. “Backbone Stack”. string Contact person. The contact person field is cleared if this field is blank. A string of 2 words or more must be type in quotation marks – e.g. “Ygdal Naouri”.

Cajun Campus CLI – Layer 2

74 Cajun P332MF User’s Guide Set interface Command Use the set interface command to configure the management interface on the Master agent of the stack. The syntax for this command is: set interface inband Example: Cajun_P330-N# set interface inband 1 149.49.42.252 255.255.255.0 Interface inband IP address set. You must reset the device in order for the change to take effect. Set port level Command Use the set port level command to set the priority level of a port. Packets traveling through a port set at normal priority should be served only after packets traveling through a port set at high priority. Packets traveling with a 802.1p priority header are not affected by this command. The syntax for this command is: set port level / {normal|high} Example: To set the priority level for port 2 on module 1 to high: Cajun_P330-N# set port level 1/2 high Port 1/2 port level set to high. inband Interface name used for the management vlan The number of the VLAN to be used for management ip_addr IP address used for managing the stack netmask Subnet mask of the management interface normal Set the port priority to regular. high Set the port priority to high.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 75 Set port negotiation Command Use the set port negotiation command to enable or disable autonegotiation on a port. For 10/100Base-T ports, autonegotiation determines the speed and the duplex mode; for 1000Base-X ports it will determine the flow control (pause) mode only; meaningless for 100Base-F ports. If autonegotiation is disabled, you can set these port parameters using the relevant CLI commands (if autonegotiation is enabled, these commands have no effect). The syntax for this command is: set port negotiation / {enable|disable} Example: To disable autonegotiation on port 1, module 4: Cajun_P330-N# set port negotiation 4/1 disable Link negotiation protocol disabled on port 4/1. Set port enable Command Use the set port enable command to enable a port or a range of ports. The syntax for this command is: set port enable [mod_num/port_num] Example: To enable port 3 on module 2: Cajun_P330-N# set port enable 2/3 Port 2/3 enabled. Set port disable Command Use the set port disable command to disable a port. The syntax for this command is: set port disable / Example: Cajun_P330-N# set port disable 5/10 Port 5/10 disabled. mod _num Number of the module port_num Number of the port.

Cajun Campus CLI – Layer 2

76 Cajun P332MF User’s Guide Set port speed Command Use the set port speed command to configure the speed of a 10/100Base-T port. You can configure the speed to either 10 Mbps or 100 Mbps. If autonegotiation mode is enabled for such ports, the port's speed is determined by autonegotiation, an error message is thus generated if you attempt to set the speed in this case. The syntax for this command is: set port speed / {10MB|100MB} Example: To configure port 2 on module 2 port speed to 10 Mbps: Cajun_P330-N# set port speed 2/2 10MB Port 2/2 speed set to 10 Mbps. Set port duplex Command Use the set port duplex command to configure the duplex mode of a 10/ 100Base-T port. You can configure the duplex mode to either Half or Full duplex. If autonegotiation mode is enabled for such ports, the port’s duplex mode is determined by autonegotiation, an error message is thus generated if you attempt to set the duplex mode in this case. The syntax for this command is: set port duplex / {full|half} Example: To set port 1 on module 2 to full duplex: Cajun_P330-N# set port duplex 2/1 full Port 2/1 set to full-duplex. Set port name Command Use the set port name to configure a name for a port. If you do not specify a name, the port name remains empty. The syntax for this command is: set port name / [] name Name assigned to the port.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 77 Example: Cajun_P330-N# set port name 1/21 arthur Port 1/21 name set. Set port trap Command Use the set port trap command to enable/disable generic SNMP uplink/ downlink traps from a port. The syntax for this command is: set port trap / {enable|disable} Example: Cajun_P330-N# set port trap 1/21 enable Port 1/21 up/down trap enabled. Set port vlan Command Use the set port vlan command to set the Port’s VLAN ID (PVID). The VLAN number must be within the range 1 to 3071. The syntax for this command is: set port vlan / Example: To set VLAN 850 to include ports 4 through 7 on module 3. Cajun_P330-N# set port vlan 850 3/4-7 VLAN 850 modified. VLAN Mod/Ports ---- ----------------------- 850 3/4-7 VLAN_num Number between 1 and 3071, identifying the VLAN.

Cajun Campus CLI – Layer 2

78 Cajun P332MF User’s Guide Set port channel Command Use the set port channel command to enable or disable a Link Aggregation Group (LAG) interface on the module. You can also add or remove a port from an existing LAG. Ensure that all ports in the LAG are configured with the same ports’ parameters such as port speed, duplex mode, VLAN ID, tagging mode, priority level. When adding a port to an existing LAG, type the same LAG-name (or no LAG-name), otherwise you will get an error message. The added port must belong to the same connector octet - refer to the “LAG” indication on device’s front panel. The syntax for this command is: set port channel / {on|off} [] Example: Cajun_P330-N# set port channel 1/6,18 on server2 Port 1/6 channel mode set to on Port 1/18 was added to channel Set port redundancy on/off Command Use the set port redundancy command to define/remove redundancy schemes between a Primary and a Secondary link. The link can be any port that does not belong to a LAG, or a LAG interface. In either case, there should not be any redundancy scheme already defined on any of the links. The syntax for this command is: set port redundancy / / {on/off} [] Example: Cajun_P330-N# set port redundancy 1/7 2/12 on red1 uplink: Port 2/12 is redundant to port 1/7. Port redundancy is active - entry is effective immediately port_list A list of ports to be aggregated, separated by commas LAG-name Optional name for the LAG interface prim_port_num Primary link of the redundancy scheme second_port_num Secondary link of the redundancy scheme redundancy_name Name for the redundancy scheme (optional)

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 79 Set port redundancy Commands Use the set port redundancy commands to enable or disable the defined redundancy schemes. Using this command will not delete existing redundancy entries. Note: You must disable Spanning Tree before you can enable redundancy. The syntax for this command is: set port redundancy {enable|disable} Example: Cajun_P330-N# set port redundancy enable All redundancy schemes are now enabled Set port mirror Command Use the set port mirror command to define a port mirroring source- destination pair in the stack. The syntax for this command is: set port mirror source-port / mirror-port / sampling {always|disable} direction {rx|both} Example: Cajun_P330-N# set port mirror source-port 1/9 mirror-port 1/10 sampling always direction both Mirroring both Rx and Tx packets from port 1/9 to port 1/10 is enabled always Keyword to activate the port mirroring entry disable Keyword to change the status of the port mirroring entry to “not ready” rx Keyword to copy only incoming traffic both Keyword to copy both incoming and outgoing traffic

Cajun Campus CLI – Layer 2

80 Cajun P332MF User’s Guide Set inband vlan Command Use the set inband vlan command to set a value for the management vlan (from 1 to 3071). The syntax for this command is: set inband vlan Example: Cajun_P330-N# set inband vlan 1 Management VLAN number set to 1 Set flowcontrol Command Use the set flowcontrol command to set the send/receive mode for flow- control frames (IEEE 802.3x or Lucent proprietary) for a full duplex port. Each direction (send or receive) can be configured separately only for Gigabit ports. Lucent proprietary flow control cannot be configured on Gigabit ports. The set flowcontrol command cannot be used on Gigabit ports for which autonegotiation is enabled. The syntax for this command is: set flowcontrol {receive|send|all} / {on|off|proprietary} value A VLAN number between 1 and 3071. Field Description receive Controls the receipt of IEEE802.3x flow-control frames on Gigabit ports only: • ON indicates that the local port will act upon flow control frames received from the far end • OFF indicates that the local port will discard flow control frames received from the far end send Controls the sending of IEEE802.3x flow-control frames from Gigabit ports only: • ON indicates that the local port is allowed to send flow control frames to the far end • OFF indicates that the local port is not allowed to send flow control frames to the far end

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 81 Example: These examples show how to use the set port flowcontrol command set: Cajun_P330-N# set flowcontrol receive 1/51 on Port 1/51 flow control receive administration status set to on (port will require far end to send flowcontrol) Cajun_P330-N# set flowcontrol send 1/51 off Port 1/51 flow control send administration status set to off (port will send flowcontrol to far end) Cajun_P330-N# set flowcontrol all 1/17 proprietary Port 1/17 flow control administration status set to proprietary Set auto-negotiation-flowcontrol-advertisement Command The set auto-negotiation-flowcontrol-advertisement command sets the flowcontrol advertisement for a Gigabit port when performing autonegotiation. The syntax for this command is: set auto-negotiation-flowcontrol-advertisement / {no-flowcontrol|asym-tx-only|sym-only|sym-and-asym-rx} all Controls the sending and receipt of flow-control frames for any type of ports: • ON indicates that the local port will both act upon and send IEEE802.3x flow control frames • OFF indicates that the local port will both discard and not send flow control frames (of any type) • PROPRIETARY indicates that the local port will both act upon and send Lucent proprietary flow control frames. no-flowcontrol The port will advertise no pause capabilities asym-tx-only The port will advertise asymmetric Tx pause capabilites only sym-only The port will advertise symmetric pause capabilites only sym-and-asym-rx The port will advertise both symmetric and asymmetric Rx pause capabilites

Cajun Campus CLI – Layer 2

82 Cajun P332MF User’s Guide Example: Cajun_P330-N# set auto-negotiation-flowcontrol-advertisement 1/51 asym-tx-only Cajun_P330-N# Port 1/51 pause capabilities was set Set trunk Command Use the set trunk command to configure the tagging mode. The syntax for this command is: set trunk / {off|dot1q} Example: Cajun_P330-N# set trunk 1/19 dot1q Dot1Q VLAN tagging set on port 1/19. Cajun_P330-N# set trunk 1/19 off No VLAN tagging set on port 1/19. Set spantree Commands Use the set spantree command to enable/disable the spanning-tree protocol for the stack. The syntax for this command is: set spantree {enable|disable} Example: Cajun_P330-N# set spantree enable bridge spanning tree enabled. off Forces the port to become a non-tagging port. The port is in the clear (tagging) mode: it will never send frames as tagged, but it will correctly interpret received tagged frames. dot1q Forces the port to become a 802.1Q tagging port. The port is in the tagging mode: it will send frames as tagged and will correctly interpret received untagged frames.

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 83 Set spantree priority Command Use the set spantree priority command to set the bridge priority for STP. The syntax for this command is: set spantree priority Example: This example shows how to set the bridge priority to 45000: Cajun_P330-N# set spantree priority 45000 Bridge priority set to 45000. Set autopartition Command Use the set autopartition command to enable or disable auto-partitioning on all the half duplex ports of the stack. The syntax for this command is: set autopartition {enable|disable} Example: Cajun_P330-N# set autopartition enable Auto-partition is enabled. Set license Command The set license command enables you to activate the SMON capability of the Cajun™ P330 stack. A Cajun P330 stack can include several Cajun P330 modules. One SMON license is required per Cajun P330 stack. Installing the license is very simple. It involves connecting a terminal to one of the Cajun P330 modules and typing in a valid license number (included in the SMON License pack) using the CLI. For a full description of the SMON License and the installation procedure please refer to the Installation Guide provided with the SMON License. bridge_priority Number representing the priority of the bridge. The priority level is from 0 to 65535, with 0 indicating high priority and 65535 indicating low priority.

Cajun Campus CLI – Layer 2

84 Cajun P332MF User’s Guide Set internal buffering Command The set internal buffering command allows you to set the size (either Maximum or Minimum) of the Receive (Rx) buffer allocated to each port of the specified module. This command is meaningless when any port of the module is operating with flow control ON. The syntax for this command is: set internal buffering {max|med|min} Example: Cajun_P330-N> set internal buffering 1 max Done. Set intermodule port redundancy Command Use the set intermodule port redundancy command to define or delete the stack’s unique intermodule redundancy scheme. The defined scheme can be enabled or disabled using the reversed set port spantree enable/disable command. The syntax for this command is: set intermodule port redundancy { on | off } []} Example: Cajun_P330-N> set intermodule port redundancy 1/7 2/12 on backbone backbone: port 2/12 is intermodule redundant to port 1/7 max Sets the internal receive buffer to its maximum size. med Sets the internal receive buffer capacity dynamically min Sets the internal receive buffer to its minimum size (this is the Default). the primary port number the secondary port number { on | off } set (on) or clear(off) the intermodule redundancy [] the name of the fast redundancy (default is 'fast')

Cajun Campus CLI – Layer 2

Cajun P332MF User’s Guide 85 Set web aux-files-url Command Use the set web aux-files-url command to allow the Device Manager to automaticaly locate the URL (the http://www address and path) of the Web server containing the Device Manager help files and Java plug-in. Note: Ensure that the Web server is always accessible otherwise Web access to the device may take a few minutes. The syntax for this command is: set web aux-files-url Example: Cajun_P330-N# set web aux-files-url //149.93.47.25/emweb-aux-files Set intelligent-multicast Command Use the set intelligent-multicast command to enable or disable the IP- multicast filtering application. The syntax for this command is: set intelligent-multicast {enable|disable} Example: Cajun_P330-N> set intelligent-multicast enable Done! Set intelligent-multicast client port pruning time Command Use the set intelligent-multicast client-port-pruning time command to define aging time for client ports. The syntax for this command is: set intelligent-multicast client-port-pruning time

Cajun Campus CLI – Layer 2

86 Cajun P332MF User’s Guide Set intelligent-multicast router port pruning time Command Use the set intelligent-multicast router-port-pruning time command to define aging time for router ports. The syntax for this command is: set intelligent-multicast router-port-pruning time