Medium Link MLS-200-C Operation & User’s Manual

Text of the manual

VDSL2 (Long Reach Ethernet)

Ethernet Bridge (Combo Interface For Copper or Coaxial) User’s Guide Version:1.0.E

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

or transmitted in any form or by any means, whether electronic, mechanical, photo copying, recording or otherwise, without the prior written permission of the publisher. FCC WARNING This equipment has been tested and found to comply with the limits for a class B device, pursuant to part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference, in which case, the user will be required to correct the interference at the user’s own expense. CE WARNING This is a Class B product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Take special care to read and understand all the content in the warning boxes: Warning

MLS-200-C is the LRE(Long Reach Ethernet) bridge that efficiently extends 10/100 Ethernet circuits

to 2 wire-Networking LAN for Internet and Intranet access. Over 915 meters (3,000feet) at 50/80Mbps using existing phone/Coaxial wire. This modem will allow Ethernet connectivity in existing facilities without pulling extra cable. This is perfect solution to Ethernet on the factory floor where systems have been upgraded from slower serial communication to Ethernet networking. Installation is easy with a single switch setting. One end is set for local and the other remote. This modem is used in phone/Coaxial wire to extend Ethernet connectivity over existing phone/Coaxial grade wire. Key Features  High-Speed 100/95Mbps communications link over existing phone line cable, Asymmetrical on LRE  50/80Mbps@ 915 meters (3,000feet), reach down to 20Mbps @ about 1.7Km(5,600feet)  Operates transparent to high layer protocols such as TCP/IP  Auto-MDIX and Auto-sensing 10Base-T or 100Base-TX and Full or Half-Duplex on the Ethernet port  Plug and Play design for simple installation, single DIP switch for configuration.  Status LEDs for simple monitoring of the device and connection status HARDWARE INSTALLATION

LED Indicators on the Front Panel

LED Status Glowing Dimming Flashing POWER DC 12 power feeding in Not powered N/A LAN1~4 Link/Act LAN Link Disconnected or Link failed Received or Transmit LINE CPE CPE side Mode CO side Mode N/A LINE Link/Act VDSL2 Link N/A Slow Flashing mean Link failed or Fast Flashing mean Received or Transmit

Ports on the Real Panel

Port Name Type Functions DC IN DC 12V Connects to the power adapter plug. CONFIG DIP SW CONFIG for MODEM LAN1~4 RJ45 Connects to Ethernet port on FTTx/xDSL Modem or Switch for Internet Access. Line/Phone RJ11 Pin 3-4 : Connects from wall outlet LINE in or connects to VDSL2 devices. Pin 5-6: Connects to PHONE or PSTN connects from wall outlet PSTN in DATA Coax Connects from wall outlet RF in or connects to VDSL2 devices. Note: RJ11 or Coax port can not using in the same time. MODEM CONFIG SETTING CONFIG DIP1 (Side) DIP2 (Interleave protection ) DIP3 (Band plan or Rate limit ) DIP4 (SNR margin) ON CPE Fast 100M/60M 6dB OFF CO Interleave 100M/95M 9dB Recommend CONFIG Setting CO [Master] CONFIG DIP1 DIP2 DIP3 DIP4 OFF ON OFF ON CPE [Slave] CONFIG DIP1 DIP2 DIP3 DIP4 ON ON OFF ON

VDSL2 Ethernet Bridge modem

Main Unit DC 12V Power Adapter (INPUT: 100~240V, 50~60Hz, 0.5A) Connects from Power Port of the main unit into a wall outlet

The figure about shows how to connect an xDSL modem to a phone line network. Follow the

same steps to connect and Ethernet device such as HUB or AP, to a phone line network. Now you should have connected the Ethernet port, Line port and the Power port to the appropriate devices or lines. LED will be as: POWER ON LAN1~4 Link/Act ON LINE Link/Act ON For more information on LEDs, see section “LED Indicators on the Front Panel”

The Bride had been designed to be a reliable and easy to use connection device. Please refer to

the list below to aid in troubleshooting. The Power (green) LED is off  Make sure the power adapter is properly plugged into a live electrical outlet. The LAN (Ethernet) or Line Link/Act LED is off.  The Ethernet or LRE device to which you are connected should be powered on and properly configured.

IEEE802.3 10BASE-T, 10Mbit/s

 IEEE802.3u 100BASE-TX, Fast Ethernet at 100Mbit/s, Auto-negoatiaton  IEEE802.3x Full Duplex and Flow Control  Protocol:  Transparent to higher layer protocols  Connectors  Fast Ethernet:Four RJ45 Connectors  RJ11:One RJ11 Female Connectors,pin 3-4 for Link line,pin 5-6 for Phone  Coaxial:One Coaxial Female Connectors for Link line  Transmission Speed and Distance  Within a distance of 300 meters maximum speed of 100/95Mbps [Copper AWG26]  Within a distance of 500 meters maximum speed of 100/95Mbps [Coaxial RG59]  Up to 5,600 Feet (-176dBm/Hz Noise Floor)  Fast Ethernet Interface  10/100 Mbps  MDI/MDI-X Auto Crossover  Network Management  Diagnosis of DSL link function  Line SNR select  Line Interleave protect  CO/CPE side select able  Band Plan profile select able  Indicators  Power LED  LAN 1~4 Link/Act LED  Line CPE/CO LED  Line Link/Act LED  Environmental Conditions  Operating Temperature :0℃ ~ 55℃ (32℉ ~ 131℉)  Storage Temperature: -10℃ ~ 65℃ (14℉ ~ 149℉)

Operating Humidity:10% ~ 90%,Non-condensing

 Power Requirement  External Power Supply:12V/1A  Power Consumption:< 5 Watts  Physical Dimension  155mm(W) x 83mm(D) x 30mm(H)  Unit Weight  380g  Emissions Compliance  FCC part 15 Class B, CE Mark  Ordering Information  MLS-200 : 1 WAN, 2 *10/100 TX Ethernet Extender over Copper Line  MLS-200-C : 1 WAN, 4 *10/100 TX Ethernet Extender over Copper/Coax Line  MLS-202-C : 2 WAN, 4 *10/100 TX Ethernet Extender over Copper/Coax Line Contact Information: Email: [email protected]

Appendix (PHY Link Rate reference Table) using AWG26 Copper

Communication distance(meter) 100M/95M Profile Line rate (Download Mbps) 100M/95M Profile Line rate (Upload Mbps) 100M/60M Profile Line rate (Download Mbps) 100M/60M Profile Line rate (Upload Mbps) 100 100 95 100 60 200 100 93 100 60 300 90 87 100 59 315 86.3 85.7 100 58 615 60.7 47.8 81.4 38.2 915 34.2 26.4 53.6 19.4 1215 26.1 20.3 37.3 8.2 1515 21.1 11.9 28.9 3.4 1615 19.4 8.6 25.5 2.3 1715 18.1 6 22.7 1.3 Appendix (PHY Link Rate reference Table) using RG59 Coaxial Communication distance(meter) 100M/95M Profile Line rate (Download Mbps) 100M/95M Profile Line rate (Upload Mbps) 100M/60M Profile Line rate (Download Mbps) 100M/60M Profile Line rate (Upload Mbps) 100 100 95 100 60 200 100 95 100 60 300 100 95 100 60 315 100 93 100 58 615 83 80 100 55 915 65 60 88 42 1215 40 50 70 29 1515 30 36 56 16 1615 25 34 51 14 1715 22 22 46 13 2000 18 20 31 9

100/60 PHY Link Rate Table

0 20 40 60 80 100 120 100 300 615 1215 1615 Distance Mbps Download Mbps Upload Mbps 100/95 PHY Link Rate Table 0 20 40 60 80 100 120 100 300 615 1215 1615 Distance Mbps Download Mbps Upload Mbps 100/95 PHY Link Rate Table 0 20 40 60 80 100 120 100 200 300 315 615 915 1215 1515 1615 1715 Distance Mbps Download Mbps Upload Mbps