Nielsen-Kellerman Kestrel 4300 Instruction Manual

Specifications

Brand: Nielsen-Kellerman
Category: Weather Station
Model: Kestrel 4300 (Instruction Manual)
File Type: PDF
File Size: —
Pages: 10

Read Online

Read the Nielsen-Kellerman Kestrel 4300 Instruction Manual online using the built-in PDF viewer.

Text of the manual

Instruction Manual For Kestrel 4300

4300 Construction Weather Tracker with Backlight www.kestrelweather.com 800.784.4221 In a hurry? Be sure to read pages 5-7 to ensure that your Kestrel is setup properly!

Kestrel® 4300 Construction Weather Tracker

BACKLIGHT BUTTON Press to activate backlight for 1 minute. MODE BUTTONS Press to change mode of measurements: Current, Min/Max/Avg, Chart. COMMAND BUTTON In Chart Screens, press to view data points. In Setup Menus, press to make selection. MANUAL MEMORY BUTTON Press to manually store current conditions to memory. MEASUREMENT BUTTONS Press to scroll between screens: Date/Time, Measurements, User Defi ned Screens. POWER/SETUP BUTTON Hold to turn power on or off . Press to enter and exit Main Setup Menu. FRONT 3 IMPELLER Sapphire jewel bearings on a user- replaceable impeller. IMPELLER COVER Swivel cover protects impeller when not in use. DATA UPLOAD OPTICAL COUPLER Software and serial port interface sold separately. BATTERY DOOR Sealed with o-ring to keep product watertight. TEMPERATURE SENSOR Hermetically sealed precision thermistor coiled to isolate from case temperature. HUMIDITY SENSOR Capacitive sensor with secondary thermistor to improve accuracy and response. SERIAL NUMBER PRESSURE SENSOR Monolithic silicon piezoresistive sensor. Do NOT insert any objects into this hole. AAA BATTERIES BACK Kestrel® 4300 Construction Weather Tracker TABLE OF CONTENTS GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 NAVIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SPECIAL FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 MAIN SETUP MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 APPLICATION EXAMPLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 MEMORY CAPABILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 DEFAULT SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FREQUENTLY ASKED QUESTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 CUSTOMER SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Congratulations on the purchase of your Kestrel 4300 Construction Weather Tracker! The Kestrel 4300 not only measures EVERY environmental condition easily, accurately, and right in the palm of your hand, but now also allows users to input a concrete temperature and determine the evaporation rate. While the Kestrel 4300 is user-friendly and simple to use, reading the instruction manual is recommended in order to use the Kestrel 4300 to its fullest potential. NK, manufacturer of Kestrel Pocket Weather Meters, is available to answer questions and provide support. Contact NK by phone: 610.447.1555, fax: 610.447.1577, email: [email protected], or web: www.nkhome.com. 5 GETTING STARTED Pouch and Lanyards A neck lanyard and wrist and a small pouch have been provided. To install the lanyard, feed the thin end of the lanyard around the metal post on the battery door (as shown in diagram). Feed the thick end of the lanyard through the loop on the thin end. Using tweezers can help. Battery Installation Use only AAA batteries. Install batteries as indicated on the battery door. After installing the batteries, the Kestrel 4300 will automatically start in the Date and Time Setting mode. (See Date and Time Setup below.) Custom settings and chart data will be saved during a battery change; only the date/time and MMA values will be lost. Turning the Kestrel Meter ON and OFF To turn the Kestrel Meter ON, press the button. To turn the Kestrel Meter OFF, hold the button for two seconds. Or, press the button, then press the button with the word OFF highlighted. (Note: your unit will continue to automatically store data when the power is turned off .) When fi rst turned on, the Kestrel Meter will display a splash screen displaying the model number, the battery indicator, and the code version. This battery indicator will indicate the percentage of battery life remaining, which is helpful in preventing unexpected dead batteries. Date and Time Setup The fi rst time that you turn on your Kestrel Meter, as well as after a battery change, you will need to set the date and time. The Introduction Screen will appear for 3 seconds, followed by the Date/ Time Setup Screen. Press the and buttons to scroll through the settings. Press the and buttons to scroll through the setting options. After entering the date and time, press the button to exit the Date/Time Setup. Then press the button again to exit the Main Setup Menu.

Kestrel® 4300 Construction Weather Tracker

NAVIGATION Measurements use and Wind Speed Temperature Wind Chill Humidity Evaporation Rate Heat Index Dew Point Wet Bulb Barometric Pressure Altitude Density Altitude The Kestrel 4300 is set up to display 11 Measurements (some are calculations) in 3 Modes. The Measurements are listed here with their corresponding screen icon. In addition to these Measurements and Modes, there are also 3 User Screens, which simultaneously show 3 current measurements, and the Date & Time Screen, which gives the current date and time. Use the and buttons to scroll through the various Measurements, followed by the 3 User Screens and the Date/Time Screen. Any of these screens can be turned off so that you can customize your Kestrel Meter to show the screens that your application requires. (See the Measurements section in the Main Menu.) The Modes are displayed below. Use the and buttons to scroll through the various Modes. From any mode, you may still scroll to a diff erent Measurement by pressing the and buttons. Current - Displays the instantaneous reading. Min/Max/Avg - Displays the Minimum/Maximum/Average readings from stored data. If there is no stored data, the values will be displayed as --.-. Chart - Displays a graphical representation of up to 1800 stored data points for each measurement. If there is no stored data, the axis will appear, but the chart will be blank. (See the following section for information on Chart Navigation.) D HI WB DP 7 Modes use and Navigation of Charts The Kestrel 4300 is capable of storing up to 1800 data points for each measurement. To review the data, press the button while viewing a chart. A cursor will appear on the most recent data point. Press the and buttons to scroll through the data points. The date and time at which the data was stored will be displayed at the bottom of the screen, and the data value will be displayed at the top of the screen. Hold down the or button to scroll quickly through the data points. Press the or button to review the data for the other measurements. Please note that the cursor will remain at the same date and time. If new data is stored while viewing chart data, the entire chart will shift left with the new data point charted on the right. The cursor will not shift with the chart. Press the button to return to the Chart Mode. Value Chart Cursor Date & Time Kestrel® 4300 Construction Weather Tracker SPECIAL FUNCTIONS Evaporation Rate The Kestrel 4300 will display the evaporation rate, based on the instantaneous air velocity, relative humidity, ambient temperature and concrete temperature. The 4300 eliminates the need to reference the American Concrete Institute issued charts. To measure the evaporation rate, you will need to input the concrete temperature. The Kestrel 4300 does not measure this, you will need to use a separate temperature measuring device to obtain the concrete temperature. Once you have measured the concrete temperature, scroll to the evaporation rate screen, then press the button. Now you can use the and buttons to enter the concrete temperature. Press the button again to exit the setting screen. To accurately measure the evaporation rate, a few precautions must be taken. The readings must be taken into the wind, approximately 20 inches above the concrete. Additionally, it is extremely important that the temperature reading is not taken in direct sunlight. You may need to shade the Kestrel Meter if the area is not normally in the shade. For example, hold a notebook or piece of plywood above the Kestrel so that it is shaded while taking the readings. (Be careful not to obstruct the air fl ow while doing so.) Failure to shade the unit may cause inaccurate Evaporation Rate readings, and will not meet the criteria in the ACI 308. Find the direction that the wind is blowing from and hold the Kestrel 4300 into the wind. You may want to scroll up to the Current Wind Speed Screen to fi nd the direction that the wind is strongest. Hold the unit vertical, and rotate it slightly to fi nd the maximum wind speed. Then scroll back to the evaporation 9 rate screen and hold the Kestrel 4300 facing that direction. The Kestrel 4300 will automatically display the instantaneous evaporation rate. Since the wind rarely blows at a constant rate, you may notice that the evaporation rate fl uctuates. For the most accurate evaporation rate readings, press the button to enter the averaging screen. This allows you to average the evaporation rate over a set time. The ACI recommends averaging for 6-10 seconds. On the average screen, press the button to start the averaging. Position the Kestrel into the wind, 20 inches above the concrete and shaded, and count 6-10 seconds, then press the – button again to stop. The screen will display the average and minimum evaporation rate readings. To clear the data, press the – button again. Press the < button to return to the current evaporation rate screen, or the > button to view the chart. Note that you may change the units of measure for Evaporation Rate under the Main Setup Menu (see the Main Menu setup section instructions). Choices are lb/ft2/hr and kg/m2/hr. User Screens The Kestrel Meter has three User Screens that can be customized to display three current measurements simultaneously. These screens can also be turned off . (See the Main Menu section for setup instructions.) Max/Avg for Wind Speed & Wind Chill The Max/Avg values for the wind speed and wind chill values are measured independently from the stored and charted data. This allows the user to start and stop the averaging period in the most appropriate manner for their application. Averaging on all wind-related values (Wind Speed and Wind Chill) will be started and stopped together.

Kestrel® 4300 Construction Weather Tracker

While viewing the Min/Max/Avg screen for any of these measurements, hold the unit into the wind, and press the button when the screen displays “--average” to begin collecting data for all measurements, and again when the screen displays “--stop” to stop collecting data and hold the values on the display. Press the button when the screen displays “--clear” to clear the data. This routine will work simultaneously for all measurements, regardless of which one is displayed while the routine is run. The Max/Avg for these wind values will not aff ect any other Min/Max/Avg or stored data. Manual Data Storage To manually store data, press the button. One of the following will appear: Data Stored (data has been captured and will appear on chart), Full (Overwrite is off and data log is full), or Off (Manual Store button has been disabled). (See the Main Setup Menu section for more information on memory.) Backlight The Kestrel Meter has a high-visibility green backlight, which makes the display easily read in low–light conditions. Press the button to activate the backlight. The light will remain activated for one minute. Press the button within one minute to deactivate the light manually. Relative Humidity The Kestrel Meter is capable of measuring RH to a high accuracy: +/– 3% RH between 5 and 95%. To ensure operation within these specifi cations, please follow these recommendations: • Avoid taking measurements in direct sunlight, which will heat the air inside the humidity sensor enclosure and cause inaccurate readings. • If your circumstances force you to expose the Kestrel Meter to a large temperature swing prior to taking a relative humidity reading (such as when taking a Kestrel Meter stored inside at 70° F outside to a temperature of 40° F), you will need to take additional steps to ensure that the Kestrel Meter’s external temperature sensor is in thermal equilibrium. 11 - Ideally, provide an airfl ow of at least 1 M/S (2.2 MPH), over the temperature sensor—point the Kestrel Meter into the airfl ow. If there is no airfl ow, simply wave the unit back and forth so air passes over the sensors. With airfl ow over the temperature sensors and humidity chambers, readings within specifi cations will be provided within two to three minutes, even after a large temperature shift. - If no airfl ow can be provided, you must allow suffi cient time for the RH value to stabilize. This can take as long as 20 minutes—the greater the temperature change, the greater the time. You can use the logging capability of the Kestrel Meter to confi rm that the unit has stabilized to a correct reading: Set the memory options to a relatively short logging interval (20 seconds works well), select the graphical display of RH, and you can see when the value is no longer changing signifi cantly. At that point, the RH value is stable and can be relied upon to be within the accuracy specifi cations. Barometric Pressure and Altitude Adjustment The Kestrel Meter measures station pressure—the actual air pressure in the measurement location—and uses this value to calculate barometric pressure and altitude. Station pressure changes in response to two things—changes in altitude and changes in the atmosphere. Because the Kestrel Meter is constantly changing location and altitude, it is important to enter adjustments or “references” when accurate pressure and altitude readings are needed. Barometric pressure is station pressure corrected to sea level. In order to make the correction, the Kestrel Meter needs an accurate reference altitude. Altitude is the height above sea level. In order to correctly calculate altitude, the unit needs an accurate barometric pressure reference, also known as an “altimeter setting”. You only need to know ONE of these values (current barometric pressure or current altitude) in order to set your Kestrel Meter up to show accurate readings. Kestrel® 4300 Construction Weather Tracker Starting with the known barometric pressure for your location You can obtain your current barometric pressure by checking an internet weather site for a nearby location, or contacting a local airport. Set this value as your reference pressure on the ALTITUDE screen to determine your correct altitude: Press the button to enter the reference setting mode. Press the button to increase the reference pressure or the button to decrease the reference pressure. You will notice that the altitude will change with changes in the reference pressure. Press the button to exit the adjustment mode. Set your Kestrel Meter down on a table and allow the altitude reading to stabilize. (Note: very small changes in pressure generate noticeable changes in altitude. In order to provide meaningful readings for activities where altitude changes quickly, the Kestrel Meter features rapid altitude response. This is why the altitude readings tend to fl uctuate by a few feet.) After obtaining a current altitude from the ALTITUDE screen, move to the BARO screen and enter this value as your reference altitude by following the same procedure. Both readings will now be accurate. Starting with a known altitude for your location You can obtain your altitude from a topographical map or local landmark. Google Earth is an excellent free program that provides the exact altitude for any given address: www.earth.google.com/. Set this value as your reference altitude on the BARO screen to determine your barometric pressure: Press the button to enter the reference setting mode. Press the button to increase the reference altitude or the button to decrease the reference altitude. You will notice that the barometric pressure will change with changes in the reference altitude. Press the button to exit the adjustment mode. Again, allow the Kestrel Meter to stabilize, then enter the value from the BARO screen as your reference pressure on the ALTITUDE screen by following the same procedure. Both readings are now accurate. 13 When reviewing stored data, remember that changes in pressure AND changes in location/altitude will aff ect the stored values. When tracking pressure changes relative to weather, set the reference altitude on the BARO screen and keep the Kestrel Meter in one location. Your graph history will now show trends in barometric pressure. Your altitude as shown on the ALTITUDE screen will change as the weather changes, but you can ignore this screen for this purpose. If you are planning a day hike would like to track your altitude, you’ll need to enter the correct reference pressure on the ALTITUDE screen as described above in “starting with the known barometric pressure.” You can now track the altitude changes as you hike. In this instance, you should ignore the values on the BARO screen, since the pressure changes will be due to changes in elevation far more than to changes in the weather. In general, changes in barometric pressure associated with weather changes are small over the course of one day, but they will aff ect the accuracy of the altimeter over time. This is why aircraft reset their altimeters at every airfi eld by entering the fi eld’s “altimeter setting” or reference pressure. Accordingly, if accurate altitude readings are your primary interest, you should reset the reference pressure on your Kestrel Meter regularly. If you encounter an elevation landmark, you can adjust the reference pressure until the altitude matches the landmark elevation. This will correct the altitude for any pressure changes due to the weather. (Or, you can obtain an updated reference pressure from the sources described above.) Some fi nal notes - If you wish to know the actual or station pressure for your location (such as for engine tuning), simply set the reference altitude on the BARO screen to “0”. In this case, the Kestrel Meter will not make any adjustment and will display the measured value. Also, the above discussion applies to ALL pressure altimeters, including one you may have in a watch or other device, but not to GPS altimeters, which use satellite triangulation to determine altitude. Note that

Kestrel® 4300 Construction Weather Tracker

with present GPS technology, pressure altimeters remain more accurate for measuring altitude change. This is why airplanes still rely on pressure altimeters, not GPS. Finally, the DENSITY ALTITUDE screen is calculated from the absolute values of station pressure, relative humidity and temperature, and is not aff ected by the reference values entered in the BARO and ALTITUDE screens. MAIN SETUP MENU You can customize your Kestrel Meter in multiple ways. Press the button to access the Main Setup Menu. Press the button to select the highlighted setting. The Main Setup Menu contains: OFF, Memory Options, Measurements, Graph Scale, Units, User Screens, System, Date & Time, Language and Restore. Off Press the then the button to turn the display off . Even when the Kestrel Meter’s display is turned off , the unit will continue to automatically store data at the defi ned Store Rate. The battery life will be decreased if data is stored frequently. The only way to completely shut off the unit is to remove the batteries. Custom settings and data will be stored when the batteries are removed. Memory Options These settings control the data storage properties. 15 Setting Description Operation Clear Log (Go/Done) All stored data is cleared. This will also clear Min/Max/Avg data. Press or to clear the log. Reset MMA (Go/Done) All Min/Max/Avg data is cleared. Chart data will remain intact. Press or to clear the MMA. Auto Store (On/Off ) When On, data is automatically stored at preset Store Rate. When Off , data is only stored when manually captured with the button. Press or to toggle between On and Off . Store Rate* (2 sec – 12 hr) The frequency at which data sets are automatically stored. (Battery life may be shortened if data is stored frequently.) Press or to increase or decrease Store Rate frequency. Overwrite (On/Off ) This setting only applies when the data log is full. When On, oldest data point is discarded to allow memory for the new data point. When Off , new data points are not saved. Press or to toggle between On and Off . Man Store (On/Off ) When On, data is stored when the button is pressed. When off , the button is disabled. Press or to toggle between On and Off . * When unit is off , data is NOT stored for 2 sec and 5 sec Store Rates. Kestrel® 4300 Construction Weather Tracker Measurements Measurement screens can be turned off , or “hidden” from the normal measurement navigation. For example, if wind chill is not of interest, it can be hidden. Press the or button to toggle between ON and OFF for each individual measurement. Press the or button to highlight the desired measurement. Press the button to return to the Main Setup Menu. Even when measurements are hidden, the Kestrel Meter will continue to log data for all measurements. If you wish to see the logged data for measurements that are hidden, simply enter the Measurement screen and turn them back on. The data will be stored in the same manner as all other measurements, as specifi ed in the Store Rate. Graph Scale These settings control the chart limits of your Kestrel Meter. Depending on the conditions, the lower and upper limits of the chart scale may need to be adjusted in order to get the best view of the data. Highlight the desired measurement by pressing the or button. Select the highlighted measurement by pressing the button. Press the or button to increase or decrease the value of the limits. Press the or button to change between the upper and lower limits. Press the button to exit and return to the Measurement Selection screen. Press the button to return to the Main Setup Menu. 17 Units The units of measure can be adjusted to best suit the application. The following units are available: Highlight the desired measurement by pressing the or button. Press the or button to scroll through the available units. Press the button to return to the Main Setup Menu. Wind Speed Temperature, Dewpoint, Wet Bulb Temp, Wind Chill & Heat Index Evaporation Rate Pressure Altitude, Density Altitude m/s meters per second km/h kilometers per hour kt knots mph miles per hour ft/m feet per minute Bft Beaufort °C Celsius °F Fahrenheit lb/ft2/hr pounds per square feet per hour kg/m2/hr kilograms per square meter per hour InHg inches mercury HPa hectopascals psi pounds per square inch mb milibar m meters ft feet

Kestrel® 4300 Construction Weather Tracker

User Screens The three User Screens can be reconfi gured to display the most appropriate information for your application. For example, if you need to monitor the wind speed, humidity and barometric pressure, a User Screen can display these current measurement values on the same screen for quick reference. Only current measurements can be selected for the User Screens - Min/Max/Avg and Charts are not available. From the Main Setup Menu, highlight the desired User Screen by pressing the or button. Press the button to select the highlighted User Screen. Press the or buttons to change lines, and the or button to scroll through the available measurements for each highlighted line. Press the button to return to the User Screen Setup Menu. Repeat above process for the other User Screens or press the button to return to the Main Setup Menu. The User Screens may also be hidden if not needed. System The display Contrast and Auto Shutdown can be reconfi gured as required. The relative humidity and pressure sensors can also be recalibrated. Press the or buttons to highlight the appropriate selection, and the or button to adjust or select. The Contrast can be adjusted for better visibility depending on the ambient lighting conditions. Press the or button to increase or decrease the contrast from 0 to 20 (0 is lightest, 20 is darkest). The display can be set to automatically turn off in order to conserve the battery life. Auto Shutdown will only occur after the preset time has elapsed without any button presses. Press the or button to scroll through the Auto Shutdown options (15 minutes, 60 minutes, Off ). Battery life will be shortened if the Auto Shutdown is turned to Off . Baro Cal - Recalibration of this sensor is not typically required, and it is not recommended that you recalibrate without speaking to an NK technician. The pressure sensor can be calibrated if necessary. It is extremely important to know the precise altitude and mean sea level barometric pressure at the time of calibrating 19 the sensor. First, set the reference altitude on the BARO measurement screen to the known altitude (see Pressure Adjustment section for instructions). Then adjust the calibrating setting on the Baro Cal screen to the known mean sea level barometric pressure. If recalibration is desired, the unit may also be returned to NK for service. Humidity Cal - Recalibration of this sensor is not typically required, and it is not recommended that you recalibrate without speaking to an NK technician. The humidity sensor can be calibrated by “teaching” it the correct humidity. Some special equipment is required for this calibration, including two hermetically sealed containers and saturated salt solutions. NK off ers a calibration kit, and instructions are available on www.nkhome.com. If recalibration is desired, the unit may also be returned to NK for service. Date & Time The date and time, as well as date and time formats, can be adjusted. The Time Formats available are 12 hour and 24 hour. The Date formats available are day/month/year and month/day/year. (See the Date and Time Set Up section for instructions.) Press the button to return to the Main Setup Menu. Language Displayed text can be set in one of fi ve languages: English, French, German, Italian or Spanish. To choose a language, use the or buttons to highlight the desired language. Press the button to select the language and return to the Main Setup Menu. Otherwise, press the button to return to the Main Setup Menu without changing languages. Restore Default settings for units of measure, date and time formats, and system settings can be restored. (See the Factory Default Settings section for more information.) Press the or button to highlight the desired default setting: Metric, Imperial or Defaults. Press the or button to reset the factory setting. Press the button to return to the Main Setup Menu. Kestrel® 4300 Construction Weather Tracker APPLICATION EXAMPLES This section provides examples of applications where a Kestrel Meter might be used, and the appropriate memory settings. Concrete Placement Auto Store On Store Rate 1 minute Overwrite On Manual Store On These settings will record continuously so you can monitor the conditions on the job site. With the automatic store rate set to 1 minute, you can store over 24 hours of data for later review. Use the manual store button to capture individual evaporation rate readings when you are measuring right over the concrete. Weather Monitoring Auto Store On Store Rate 1 hr Overwrite On Man Store Off These settings will allow you to track conditions for 2 months. When the memory is full, each new measurement will be stored in place of the oldest data point. The charts will provide a quick look at the recent weather conditions. Keep an eye out for falling barometric pressure, which indicates that a storm is coming. 21 Hiking/Camping for the Weekend Auto Store On Store Rate 20 min Overwrite Off Man Store On These settings will allow you to track the conditions for over 20 days. Measurements will be stored every 20 minutes, and stop storing when the log is full. This will let you review the trip at your convenience when you return. You can also manually store the conditions, in case you get caught in 40 mile per hour winds or make it to the top of a mountain. For more detailed information on your trip, set the Store Rate to 2 hours overnight, and 10 minutes during the day. Soaring/Hang Gliding Auto Store On Store Rate 2 min Overwrite Off Man Store On These settings will allow you to track all conditions for 46 hours. Chart your altitude changes, watch how the temperature and humidity vary with altitude, and log your apparent speed. Data will no longer be stored once the log is full, in order to preserve it until it can be reviewed later. Be sure to clear the data log just before your fl ight.

Kestrel® 4300 Construction Weather Tracker

Skydiving Auto Store On Store Rate 2 sec Overwrite Off Man Store Off These settings will allow you to record a detailed account of your jump. Be sure to clear the data log just before jumping. As you descend toward the ground, you will be tracking the altitude every two seconds, as well as the conditions at that altitude. The chart will clearly show the point at which the parachute opens, as well as the point you get back on the ground. HVAC - Environmental Monitoring Auto Store On Store Rate 5 min Overwrite On Man Store Off These settings will record conditions every fi ve minutes, for a total storage of almost 6 days. You can monitor the conditions in a laboratory or manufacturing plant, both day and night, to determine if the climate control is working properly. Or you can examine the eff ect on the environment when employees enter and exit the building. 23 HVAC/R - System Balancing Auto Store Off Store Rate — Overwrite Off Man Store On These settings will require you to press the Manual Store Button in order to store any data at a duct, hood, vent, or other air system. The meter will not store any data automatically. Be sure to record the location and date/time of storage for reference when reviewing the data. After storing the conditions at each location, simply review the data and balance the system. Kestrel® 4300 Construction Weather Tracker MEMORY CAPABILITIES Store Rate Total Memory 2 sec 59 minutes, 44 seconds 5 sec 2 hours, 2 min, 20 sec 10 sec 4 hours, 58 min, 40 sec 20 sec 9 hours, 57 min, 20 sec 30 sec 14 hours, 56 min 1 min 1 day, 5 hours, 52 min 2 min 2 days, 11 hours, 44 min 5 min 6 days, 5 hours, 20 min 10 min 12 days, 10 hours, 40 min 20 min 24 days, 21 hours, 20 min 30 min 37 days, 8 hrs 1 hr 74 days, 16 hrs 2 hr 149 days, 8 hrs 5 hr 373 days, 8 hrs 12 hr 896 days 25 GLOSSARY The below defi nitions have been greatly simplifi ed in order to keep this section brief. We strongly recommend that anyone who wishes to make use of these measurements refer to one of the many excellent weather references available for a more in-depth defi nition. On the internet, visit www.usatoday.com or www.noaa.gov. Or, locate the USA Today publication, The Weather Book. Please note that any words in a defi nition printed in italics are themselves defi ned in this glossary. Altitude The distance above sea level. The Kestrel Meter calculates altitude based on the measured station pressure and the input barometric pressure - or “reference pressure”. Barometric Pressure The air pressure of your location reduced to sea level. Pressure will change as weather systems move into your location. Falling pressure indicates the arrival of a low pressure system and expected precipitation or storm conditions. Steady or rising pressure indicates clear weather. A correct altitude must be input for the Kestrel Meter to display barometric pressure correctly. Density Altitude The altitude at which you would be, given the current air density. Often used by pilots in order to determine how an aircraft will perform. Also of interest to individuals who tune high performance internal combustion engines, such as racecar engines. Dewpoint The temperature to which air must be cooled in order for condensation to occur. The diff erence between dewpoint and temperature is referred to as the “temperature/dew point spread”. A low dewpoint spread indicates high relative humidity, while a large dewpoint spread indicates dry conditions.

Kestrel® 4300 Construction Weather Tracker

Heat Index A practical measure of how hot the current combination of relative humidity and temperature feels to a human body. Higher relative humidity makes it seem hotter because the body’s ability to cool itself by evaporating perspiration is reduced. Reference Pressure The local barometric pressure. Input to the altitude screen to provide correct altitude readings. Also known as the altimeter setting. Relative Humidity The amount of water vapor actually in the air divided by the maximum amount of water vapor the air could hold at that temperature, expressed as a percentage. Station Pressure The air pressure of your location, NOT reduced to the sea level equivalent. Temperature The ambient air temperature. Wet Bulb Temperature The lowest temperature to which a thermometer can be cooled by evaporating water into the air at constant pressure. This measurement is a holdover from the use of an instrument called a sling psychrometer. To measure wet bulb temperature with a sling psychrometer, a thermometer with a wet cloth covering over the bulb is spun rapidly through the air. If the relative humidity is high, there will be little evaporative cooling and the wet bulb temperature will be quite close to the ambient temperature. Some exercise physiology guides use wet bulb temperature, rather than heat index, as a measure of the safety of exercise in hot and humid conditions. Wind Chill The cooling eff ect of combining wind and temperature. The wind chill gives a more accurate reading of how cold it really feels to the human body. The Kestrel Meter’s wind chill is based on the National Weather Service standards as of November 1, 2001. 27 DEFAULT SETTINGS UNIT METRIC IMPERIAL Wind Functions M/s mph Temperature Functions °C °F Barometric Pressure hPa inHg Altitude Functions M Ft Time Format 24 hour 12 hour Date Format Day/month/year Month/day/year SETTING FACTORY DEFAULT Automatic Data Store On Data Store Rate 1 hour Data Overwrite On Manual Data Store On User Screen 1 Wind speed, temperature, humidity User Screen 2 Humidity, dewpoint, wet bulb User Screen 3 Pressure, altitude, density altitude Display Contrast 10 Automatic Shutdown 15 minutes Language English PC Upload Stored data may be uploaded to a PC with the optional Kestrel Interface. Kestrel® 4300 Construction Weather Tracker FREQUENTLY ASKED QUESTIONS How can a Kestrel 4300 help prevent plastic shrinkage cracks? Plastic shrinkage cracks occur when the surface of the concrete dries rapidly and shrinks before it can gain suffi cient tensile strength to resist cracking. When ambient conditions and concrete temperatures combine to produce conditions that create a high evaporation rate, the chances of the surface drying prematurely and shrinkage cracks forming increases. Although most people associate high evaporation rates with hot, dry weather, it’s important to note that placing hot concrete on a cold, dry day can actually create a much worse condition. A Kestrel 4300 measures the ambient temperature, wind speed and relative humidity with great accuracy. With the manual input of the concrete temperature, it can calculate the evaporation rate which can help determine how prone the job is to plastic shrinkage cracks. Evaporation rate can also be determined from the ACI 308 charts, though the Kestrel Meter provides a more accurate, convenient way to take the measurement. How do I set my Kestrel Meter to read the correct barometric pressure and altitude? To measure these values accurately, you must know either your current pressure or altitude. If you know the current barometric pressure, go to the altitude screen, and press the – button to enter the reference pressure. As you adjust the reference pressure, you will notice that the altitude will change. Once the reference pressure is entered, note the new altitude, and go to the barometric pressure screen. Press the – button to enter this altitude as the reference altitude. Your Kestrel Meter is now displaying the accurate pressure and altitude. (If you start with a known altitude, simply start with entering this value as the reference altitude on the barometric pressure screen. The adjust the reference barometric pressure on the altitude screen.) You will need to update the reference pressure and altitude as you change altitude or the weather changes. For more information on this topic, see the Barometric Pressure and Altitude Adjustment section under “Special Functions.” 29 Why is my Kestrel Meter is not registering wind speed? It probably just needs a replacement impeller. You can verify this by removing the impeller (press fi rmly on the sides of the impeller), and turn the unit on to the wind speed screen. Hold the Kestrel Meter near a television, computer monitor or some electronic device and it will display a wind speed. Or, wave a magnet (like a refrigerator magnet) back and forth by the Kestrel Meter. If the Kestrel Meter is working properly, you will register a wind speed reading, even though there is no impeller installed. Simply purchase a new impeller and your Kestrel Meter’s wind speed readings will be restored to factory calibration. What is the best way to take accurate temperature and humidity readings? Avoid taking measurements in direct sunlight, and be sure there is airfl ow over the sensors. Especially if you expose the Kestrel Meter to a large temperature swing prior to taking a reading (such as taking a Kestrel Meter from the indoors to the outdoors in the winter), airfl ow over the sensors is necessary to measure accurate temperature and humidity readings. You can ensure airfl ow by either placing the Kestrel Meter in a breeze, or by waving it back and forth. If no airfl ow can be provided, you must allow up to 20 minutes for the values to stabilize and accurate readings to be displayed. Can my Kestrel Meter measure water speed by placing it in wind speed mode and submerging it? Even though your Kestrel Meter is fully waterproof and can be submerged without damage, the viscosity of water is diff erent than that of air. The Kestrel Meter will display a value, but the readings will not be the accurate water speed. Why does my screen turn black in the heat? Why does screen become sluggish or blank in the cold? The liquid crystal display used in Kestrel Meters has an operational temperature range of -49.0 to 257.0°F (-45.0 to 125.0°C). Above this temperature, the whole screen will turn black. Below this temperature, the

Kestrel® 4300 Construction Weather Tracker

liquid crystals will freeze and not display a reading. Even in these conditions, your Kestrel Meter will still continue to measure and record readings as specifi ed by the automatic and manual data storage rates, you will just not be able to read the display until the environment’s temperature is within the operational range. In cold environments, you can keep the Kestrel Meter warm in your pocket and remove it only to take readings. Be sure to wave the unit back and forth to create airfl ow over the sensors to ensure the most accurate reading possible. Why doesn’t my Kestrel Meter match the local Weather Report? Obtaining a weather report from a local television station, airport or internet site will give you the weather where those instruments are, which is not necessarily the same as where you are. Your Kestrel Meter is measuring the conditions right where you are. The nature of microclimates and weather fronts is that they are varied, and even locations as close as a mile apart can have diff erent weather readings. You can certainly use these weather reporting services for good estimates of what the conditions will be, but for the most accurate readings at your particular location, the Kestrel Meter is better. 31 CUSTOMER SERVICE Kestrel Pocket Weather Meters Warranty NK does not believe in “disposable electronics.” We know that Kestrel Meters don’t typically lead pampered lives, and we design them for years of performance in tough conditions. Every Kestrel Meter is designed and manufactured at NK’s facility in Boothwyn, Pennsylvania, USA. We guarantee every Kestrel Pocket Weather Meter to be free of defects in materials and workmanship for a period of FIVE YEARS from your date of purchase. We will repair or replace any defective product or part when notifi ed within the warranty period, and will return the product via domestic ground shipping at no charge. Additionally, each Kestrel Meter has a 30-day money back guarantee. The following issues do not result from a manufacturing defect and are not covered under this warranty: damage due to improper use or neglect (including corrosion), impact damage, modifi cations or attempted repairs by someone other than an authorized NK repair agent, impeller failure not caused by a manufacturing defect, normal wear from use of the product, failed batteries, and re-calibration beyond 30 days from your date of purchase. Your warranty period will be measured from your date of purchase. The best way to ensure full warranty coverage is to REGISTER your NK product promptly on our website: www.kestrelweather.com. We keep your registration information strictly confi dential and do not sell it, share it, or use it for anything but product- related information bulletins (which you may decline receiving). If you do not register and cannot provide proof of purchase, your warranty period will be measured from our date of manufacture, determined by serial number. Kestrel® 4300 Construction Weather Tracker We request that you contact NK if you feel your product is not working properly. We can often solve product issues by phone or e-mail, saving you the time and expense of returning the unit. If we require the product to be returned, we will issue a Return Authorization to expedite the handling of your warranty claim. The Kestrel 4300 is covered by the following US patents: 5,783,753, 5,939,645, 6,257,074, and 7,059,170. Calibrations, Certifi cations and Service Every NK product is tested and calibrated before it leaves our factory. We guarantee that it will perform within specifi cations when you receive it. Each Kestrel Meter comes with a Certifi cate of Conformity, with the stated specifi cations for that product on the back. If you feel an NK product is not meeting specs when you receive it, call us and we’ll make sure you are operating it correctly. If it still appears that it may be out of spec, return it to us within 30 days of purchase and we will test and recalibrate all values at no charge. Beyond 30 days, we off er reasonably-priced tests, calibration services and N.I.S.T. certifi ed calibrations as well as Kestrel Meter tune-ups. All of our measurements are traceable to the National Institute of Standards and Technology, ensuring the highest level of accuracy. Our primary Calibration Standards are sent for calibration in accordance with N.I.S.T. requirements and based on a regular schedule. Only approved laboratories and N.I.S.T themselves are used for these calibration services. Incoming and outgoing data is supplied with the certifi cate of calibration. We also off er full factory service on every product we manufacture for as long as we make the product (and as long after as component availability permits). If we can’t repair a product, we will off er you a brand-new replacement under our Customer Care Program (even for accidental damage and misuse). Cost of repairs and other important information can be found on our website. 33 We request that you contact NK if you feel your product is not working properly. We can often solve product issues by phone or e-mail, saving you the time and expense of returning the unit. If we require the product to be returned, we will issue a Return Authorization to expedite the handling of your claim. Visit www.kestrelweather.com for more information and pricing for these services. Lifetime Customer Care Warranty NK wants you to be an NK customer for life, so we take care of you even beyond the terms of the above warranty with our Customer Care Program. Trade-in any Kestrel Pocket Weather Meter, no matter the age or condition, and receive a generous discount on the replacement product (same model only). Our Customer Care Program applies only as long as we manufacture the product, and does not cover product upgrades.

Kestrel® 4300 Construction Weather Tracker

Need Help? Our NK Knowledge Center has answers to many common questions, along with tips and tricks for using NK products. It’s available 24-7 at www.nkhome.com/knowledgecenter/. For email assistance with the installation or operation of your NK product, write [email protected]. For help with an apparent malfunction, or to arrange or inquire about a repair, write [email protected]. Or call 800.784.4221 (610.447.1555 outside of the USA), Monday to Friday, 9 to 5, East Coast Time. 35 Kestrel® Pocket Weather® Meters are designed and manufactured in the USA by: Instruction Manual for Kestrel 4300 version: 4.23 ALL Please register your Kestrel Meter at www.KestrelWeather.com NIELSEN-KELLERMAN 21 Creek Circle, Boothwyn, PA 19061 Phone: (610) 447-1555 Fax: (610) 447-1577 Web: www.kestrelweather.com Email: [email protected] Kestrel® 4300 Construction Weather Tracker Kestrel® Pocket Weather® Meters are designed and manufactured in the USA by: Instruction Manual for Kestrel 4300 version: 4.23 ALL NIELSEN-KELLERMAN 21 Creek Circle, Boothwyn, PA 19061 Phone: (610) 447-1555 Fax: (610) 447-1577 Web: www.kestrelweather.com Email: [email protected] Please register your Kestrel Meter at www.KestrelWeather.com