Metapace reserves the right to make changes in specifications and other information

contained in this document without prior notice, and the reader should in all cases consult seller to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of seller. Seller shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of seller. © 2011 All rights reserved.

Table of Contents

iii Table of Contents Introduction ............................................................................................. 1 Components ..................................................................................................... 1 Maintenance ..................................................................................................... 1 Caution and Serial Number Labels ................................................................... 2 Cable Installation and Removal ........................................................................ 3 Scanner Operation Audible Indicators ............................................................................................. 4 Visual Indicators ............................................................................................... 5 Failure Modes ................................................................................................... 6 Typical Depth of Field ....................................................................................... 6 Troubleshooting Guide ........................................................................... 7 Design Specifications ........................................................................... 10 Configuration Introduction Bar Code Configuration Methods ................................................................... 12 Single-Code Method .................................................................................... 12 Multi-Code Method ...................................................................................... 12 Returning to Factory Defaults ......................................................................... 13 Code Types and Decode Rules 2 of 5 Codes ................................................................................................... 14 Additional Decode Features ........................................................................... 14 Supplements .......................................................................................... 15 Scanner Operation Redundant Scans ........................................................................................... 16 Data Transmission Delays .............................................................................. 16 Laser/Scan Modes ......................................................................................... 16 Prefixes/Suffixes User Configurable Prefixes, All Data .............................................................. 17 Standard Prefix Characters ............................................................................ 17 11 17 17 17 18 18 1 1 2 2 3 4 5 8 8 9 11 13 13 13 14 15 15 16

Standard Suffix Characters

............................................................................ 17 User Configurable Suffixes, All Data .............................................................. 18 Code Formatting UPC/EAN Formatting ..................................................................................... 19 Keyboard Enable Keyboard Emulation ........................................................................... 21 Code Bytes Usage Code Bytes 0-9 ............................................................................................... 23 Reserved Codes ............................................................................................. 24 Code Type Table ............................................................................................ 24 ASCII Reference Table ................................................................................... 25 Extended Key Code Reference Table ............................................................ 29 Limited Warranty ................................................................................... 31 iv Standard Suffix Characters ............................................................................ 17 User Configurable Suffixes, All Data .............................................................. 18 Code Formatting UPC/EAN Formatting ..................................................................................... 19 Keyboard Enable Keyboard Emulation ........................................................................... 21 Code Bytes Usage Code Bytes 0-9 ............................................................................................... 23 Reserved Codes ............................................................................................. 24 Code Type Table ............................................................................................ 24 ASCII Reference Table ................................................................................... 25 Extended Key Code Reference Table ............................................................ 29 Limited Warranty ................................................................................... 31 18 19 20 23 24 24 25 29 31

Red Output Window (Laser Aperture)

2 Trigger 3 Pinhole for Cable Release (see page 3) 4 10-Pin RJ45, Female Socket 5 Beeper Hole 6 LED Indicator (see page 5) Figure 1. Scanner Components Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non- abrasive cleaning cloth then gently wipe the window clean. If the unit’s housing requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit’s exterior. 1

Caution and Serial Number Labels

Figure 2. Label Location on the Bottom of the Scanner Caution: To maintain compliance with applicable standards, all circuits connected to the imager must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source. Item Number, Serial Number and Compliance Information location. 2

Cable Installation and Removal

Installation 1. Insert the cable’s modular connector into the socket on the scanner. 2. Pull gently on the cable strain relief to ensure the cable is installed. Figure 3. Removal Turn off power to the host system before removing the cable from the scanner. 1. Locate the small pinhole on the front side of the scanner near the end of the handle. 2. Bend an ordinary paper clip into the shape shown. 3. Insert the paper clip (or other small metallic pin) into the small pinhole. There will be a faint ‘click’ when the connector’s lock releases. 4. Pull gently on the cable’s strain relief to remove the cable. Figure 4. 3

When the scanner is operational, the scanner provides audible feedback to

indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). One Beep – On Power Up When the unit powers up, the green LED turns on, then the red LED flashes and the scanner beeps once. The red LED will remain on for the duration of the beep. The scanner is now ready to scan. One Beep – During Operation When the scanner successfully reads a bar code, the red LED will flash and the scanner beeps once (if programmed to do so). If the scanner does not beep once and the red light does not flash, then the bar code has not been successfully read. Three Beeps – During Operation When entering the configuration mode, the red LED flashes while the scanner simultaneously beeps three times. The red LED continues to flash until the unit exits configuration mode. Upon exiting configuration mode, the scanner beeps three times and the red LED stops flashing. When configured for communication timeout, three beeps during operation indicates that a communication timeout has occurred. 4

The scanner is equipped with a red LED and green LED, which indicate the

scanner’s state and the status of the current scan respectively when the unit is in operation. Figure 5. LED Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green Steady green indicates normal pulse or continuous laser operation. Accompanied by a razzberry tone, a steady green LED indicates that an invalid bar code has been scanned. Flashing Green After a period of inactivity, the ON time of the pulsing laser will be shortened. During this time the green LED will flash. This indicates that the scanner is in a power saver mode. When a bar code enters the laser field, the scanner will wake up and return to normal pulse mode. Steady Green and Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep. If the red LED does not flash and the scanner does not beep, the bar code has not been successfully read. Steady Green and Steady Red After a successful read, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted. Steady Green and Continuous Flashing Red When entering the configuration mode, the red LED will flash, the green LED will turn on and the scanner will beep three times. The red LED will continue to flash and the green LED will stay on until the unit exits the configuration mode. LED 5

One Razzberry Tone – On Power Up

This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to an Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an Authorized Service Center. Three Beeps – On Power Up If the scanner beeps three times on power up, then the non-volatile memory (NovRAM) that holds the scanner configuration has failed. You must return the unit for repair to an Authorized Service Center. Typical Depth of Field by Bar Code Element Width Bar Code Element Width Depth of Field Start (From Scanner Face) End (From Scanner Face) 0.13 mm 5.2 mil 76 mm (3") 127 mm (5") 0.19mm 7.5 mil 51 mm (2") 203 mm (8") 0.26 mm 10.4 mil 25 mm (1") 229 mm (9") 0.33 mm 13 mil 13 mm (0.5") 254 mm (10") 8

The following guide is for reference purposes only. Contact a customer service

representative to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces The unit has no LEDs, beep or laser. No power is being supplied to the unit. Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit. No power is being supplied to the unit from host. Some host systems cannot supply enough current to power the scanner. A power supply may be needed. At power up the unit beeps two times and alternately flashes the LEDs. There is a ROM failure. A flash ROM upgrade is required. At power up the unit beeps three times. There is a non- volatile RAM failure. Contact a customer service representative. At power up there is a continuous razz tone. There has been a diagnostic failure. At power up there is a razz tone and the green LED flashes. There is a VLD failure. At power up there is a razz tone and both LEDs flash. There is a scanning mechanism failure. The unit scans, communicates and beeps twice. The same symbol timeout is set too short. Adjust the same symbol timeout for a longer time. The unit powers up, but does not beep. The beeper may be disabled or no tone has been selected. Enable beeper and select a tone. 7 Troubleshooting Guide The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces The unit has no LEDs, beep or laser. No power is being supplied to the unit. Check the transformer, the outlet and power strip. Make sure the cable is plugged into the unit. No power is being supplied to the unit from host. Some host systems cannot supply enough current to power the scanner. A power supply may be needed. At power up the unit beeps two times and alternately flashes the LEDs. There is a ROM failure. A flash ROM upgrade is required. At power up the unit beeps three times. There is a non- volatile RAM failure. Contact a customer service representative. At power up there is a continuous razz tone. There has been a diagnostic failure. At power up there is a razz tone and the green LED flashes. There is a VLD failure. At power up there is a razz tone and both LEDs flash. There is a scanning mechanism failure. The unit scans, communicates and beeps twice. The same symbol timeout is set too short. Adjust the same symbol timeout for a longer time. The unit powers up, but does not beep. The beeper may be disabled or no tone has been selected. Enable beeper and select a tone. 8 9

The unit powers

up, but does not scan and/or beep. The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify the type of bar code being read has been selected. The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length. Verify the bar code being scanned falls into the configured criteria. The scanner defaults to a minimum of three-character bar code. Serial Emulation USB Interfaces The unit scans a bar code, but locks up after the first scan and the red LED stays on. The unit is configured to support some form of host handshaking but is not receiving the signal. If the unit is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly. The unit scans, but the data transmitted to the host is incorrect. The unit’s data format does not match the host system’s requirements. Verify the unit’s data format matches that required by the host. Make sure that the unit is connected to the proper host port. The unit beeps at some bar codes but NOT for others of the same bar code symbology. The bar code may have been printed incorrectly. Check if it is a check digit/character/or border problem. The unit is not configured correctly for the type of bar code being scanned. The minimum symbol length setting does not work with the bar code. Check if the correct minimum symbol length is set. Keyboard Wedge Interface The unit scans the bar code but there is no data. The unit’s configuration is not correct. Make sure the scanner is configured for the appropriate mode. 10

Visible Laser Diode (VLD) @ 650 nm

Laser Power: Less than 1.0 mW average Depth of Scan Field: 12.7 mm – 254 mm (0.5" – 10") 0.33 mm (13 mil) Bar Code Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.1016 mm (4 mil) Decode Capability: Reads standard 1D and GS1 DataBar symbologies. System Interfaces: USB, Keyboard Wedge Print Contrast: 35% minimum reflectance difference No. Characters Read: Up to 80 data characters. The maximum number will vary based on symbology and density. Scan Angle: 46° Horizontal Pitch, Yaw: 68°, 52° Beeper Operation: 7 tones or no beep Indicators (LED): Red = good read Green = laser on, ready to scan Mechanical Length: 110 mm (4.3") Width: 70 mm (2.8") Height: 153 mm (6.0") Weight: 120 g (4.23 oz) Specifications subject to change without notice. 11

5VDC ± 0.25V

Operating Power: Standby: 700 mW Decoding USB: 975 mW Decoding KBW: 875 mW Operating Current: Standby: 140 mA average @ 5VDC Decoding USB: 195 mA average @ 5VDC Decoding KBW: 175 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A Environmental Temperature: Operating: 0°C to 40°C (32°F to 104°F) Storage: -40°C to 60°C (-40°F to 140°F) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 4842 Lux (450 footcandles) Shock: Designed to withstand 1.0 m (3.3 ft.) drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications subject to change without notice. 11 Electrical Input Voltage: 5VDC ± 0.25V Operating Power: Standby: 700 mW Decoding USB: 975 mW Decoding KBW: 875 mW Operating Current: Standby: 140 mA average @ 5VDC Decoding USB: 195 mA average @ 5VDC Decoding KBW: 175 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A Environmental Temperature: Operating: 0°C to 40°C (32°F to 104°F) Storage: -40°C to 60°C (-40°F to 140°F) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 4842 Lux (450 footcandles) Shock: Designed to withstand 1.0 m (3.3 ft.) drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications subject to change without notice. 11 Electrical Input Voltage: 5VDC ± 0.25V Operating Power: Standby: 700 mW Decoding USB: 975 mW Decoding KBW: 875 mW Operating Current: Standby: 140 mA average @ 5VDC Decoding USB: 195 mA average @ 5VDC Decoding KBW: 175 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A Environmental Temperature: Operating: 0°C to 40°C (32°F to 104°F) Storage: -40°C to 60°C (-40°F to 140°F) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 4842 Lux (450 footcandles) Shock: Designed to withstand 1.0 m (3.3 ft.) drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications subject to change without notice. 11 Electrical Input Voltage: 5VDC ± 0.25V Operating Power: Standby: 700 mW Decoding USB: 975 mW Decoding KBW: 875 mW Operating Current: Standby: 140 mA average @ 5VDC Decoding USB: 195 mA average @ 5VDC Decoding KBW: 175 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A Environmental Temperature: Operating: 0°C to 40°C (32°F to 104°F) Storage: -40°C to 60°C (-40°F to 140°F) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 4842 Lux (450 footcandles) Shock: Designed to withstand 1.0 m (3.3 ft.) drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications subject to change without notice. 12

Your new scanner has been factory configured with a set of default parameters.

Since many host systems have unique formats and protocol requirements, a wide range of configurable features that may be selected using this bar code based configuration tool are provided. Once the configuration is completed, the scanner stores the settings in nonvolatile memory (NOVRAM). NOVRAM saves the settings when the power is off. Note: Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code configuration method. Bar Code Configuration Methods Scanners can be bar code configured in two ways: the Single-Code Method and the Multi-Code Method. Single-Code Method Most features can be enabled or disabled using the Single-Code Method. 1. Power up the scanner. 2. Scan the bar code for the desired feature. 3. The scanner will emit a multi-toned beep to indicate the configuration has been saved to NOVRAM. Multi-Code Method All features can be enabled or disabled using the Multi-Code Method. A feature marked with a tilde ( ~ ) requires the Multi-Code Method. 1. Power up the scanner. 2. Scan the Enter/Exit Configuration Mode bar code (3 beeps). 3. Scan the bar code for the desired feature (1 beep). Multiple features can be enabled/disabled before scanning the enter/exit configuration mode bar code. 4. Scan the Enter/Exit Configuration Mode bar code (3 beeps) and save the new configuration. To abort a configuration change, power off the scanner before scanning the Enter/Exit code. Enter/Exit Configuration Mode ³ 9 9 9 9 9 9 13

Returning to Factory Defaults

Scan the Recall Defaults bar code to erase all previous settings and return the scanner to its factory default communication protocol. Recall Defaults ³ 9 9 9 9 9 8 14

Code Types and Decode Rules

14 Code Types and Decode Rules Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code configuration method. 2 of 5 Codes ³ 9 0 1 6 0 0 ~ ITF Symbol Length Lock 1 – To specify a first ITF symbol length lock, scan this bar code and the appropriate code byte sequence located on page 23. ³ 9 0 1 7 0 0 ~ ITF Symbol Length Lock 2 – To specify a second ITF symbol length lock, scan this bar code and the appropriate code byte sequence located on page 23. ³ 9 0 3 4 0 0 ~ ITF Minimum Symbol Length – To specify a minimum number of ITF characters to be decoded, scan the appropriate code byte sequence located on page 23. Additional Decode Features ³ 9 0 1 8 0 0 ~ Minimum Symbol Length – Single-line default is 3. Combine this code with the proper code bytes (on page 23), to specify the minimum number of characters in all non-UPC/EAN bar codes. ³ 9 0 1 9 0 0 ~ Symbol Length Lock – Combine this code with the proper code bytes, to lock the bar code’s length into place. 14 15

Enable Bookland (979) Supplement Required

³ 1 2 5 1 0 4 * Disable Bookland (979) Supplement Required ³ 1 0 1 4 1 7 Enable Bookland (978) Supplement Required ³ 1 0 1 4 0 7 * Disable Bookland (978) Supplement Required ³ 1 0 1 3 1 4 Enable 977 (2 Digit) Supplement Required – The scanner will require a 2 digit supplement to be scanned when an EAN-13 code begins with 977. ³ 1 0 1 3 0 4 * Disable 977 (2 Digit) Supplement Required ³ 1 0 1 3 1 5 Enable ISBN Check Digit Transmission ³ 1 0 1 3 0 5 Disable ISBN Check Digit Transmission ³ 1 0 1 3 1 7 Enable Bookland to ISBN Conversion ³ 1 0 1 3 0 7 * Disable Bookland to ISBN Conversion 16

* 0 Redundant Scans – Requires 1 good decode

for a good scan. ³ 3 0 1 1 1 0 1 Redundant Scan – Requires 2 consecutive decodes of the same bar code data for a good scan. Data Transmission Delays Use these codes to select the amount of delay between sending data characters from the scanner to the host. This helps prevent the scanner from overflowing host-input buffers. ³ 8 1 8 8 1 0 * 1 msec Intercharacter Delay ³ 8 1 8 8 1 0 0 10 msec Intercharacter Delay ³ 8 1 8 8 2 5 0 25 msec Intercharacter Delay ³ 9 1 8 8 0 0 ~ Variable msec Intercharacter Delay – Scan this bar code and a sequence of code bytes on page 23 to set the delay between characters sent to the host system (range from 1 to 255 msecs.). Laser/Scan Modes ³ 1 1 8 7 0 3 Enable Automatic Scanning ³ 4 1 8 3 3 4 Continuous Blinky Scan – The laser blinks continuously and the IR is inactive. ³ 4 1 8 3 5 4 Enable Manual Trigger – The laser activates when the CodeGate button is pressed. 17

Scan the Enter Configuration Mode bar code before trying to set these features

(see the Multi-Code Method on page 12.) User Configurable Prefixes, All Data ³ 9 0 3 5 0 0 ~ Configurable Prefix Character #1 – A prefix ID can be added and assigned for data transmission. Use this code with a code byte sequence, on page 23, which represents the desired character. ³ 9 0 3 6 0 0 ~ Configurable Prefix Character #2 – Assigns a second configurable prefix character. Standard Prefix Characters ³ 1 1 6 6 1 5 Enable STX Prefix – The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. ³ 1 1 6 6 0 5 * Disable STX Prefix Standard Suffix Characters ³ 1 1 6 6 1 3 * Enable CR Suffix – The scanner transmits a carriage return after each bar code. ³ 1 1 6 6 0 3 Disable CR Suffix ³ 1 1 6 6 1 2 * Enable LF Suffix – The scanner transmits a line feed after each bar code. Disabled when keyboard wedge defaults are loaded. ³ 1 1 6 6 0 2 Disable LF Suffix 18

Enable Tab Suffix – The scanner will transmit a

TAB (ASCII 09H) after each bar code. ³ 1 1 6 6 0 0 * Disable Tab Suffix ³ 1 1 6 6 1 4 Enable ETX Suffix – The scanner will transmit End of TeXt (ASCII 03H) after the bar code date. ³ 1 1 6 6 0 4 * Disable ETX Suffix ³ 1 1 6 6 1 6 Enable UPC Suffix ID – The scanner will transmit a suffix after any UPC/EAN bar code. The suffixes are A (UPC-A), E (UPC-E), F (EAN-13) and F (EAN-8). ³ 1 1 6 6 0 6 * Disable UPC Suffix ID ³ 9 4 1 6 0 0 Enable NCR Suffix Character User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code Method on page 12. ³ 9 0 4 5 0 0 ~ Configurable Suffix Character #1 – A suffix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence, on page 23, which represents the desired character. ³ 9 0 4 6 0 0 ~ Configurable Suffix Character #2 – Assigns a second configurable suffix character. 19

* Transmit UPC-A Check Digit

³ 1 0 7 5 0 7 Do Not Transmit UPC-A Check Digit ³ 1 0 7 5 1 6 Transmit UPC-E Check Digit ³ 1 0 7 5 0 6 * Do Not Transmit UPC-E Check Digit ³ 1 0 7 5 1 5 Expand UPC-E to 12 Digits – Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes. ³ 1 0 7 5 0 5 * Do Not Expand UPC-E to 12 Digits ³ 1 0 7 6 0 2 * Send Number System on Expanded UPC E ³ 1 0 7 6 1 2 Do Not Send Number System on Expanded UPC E ³ 1 0 7 5 1 0 Enable GTIN Formatting ³ 1 0 7 5 0 0 * Disable GTIN Formatting ³ 1 0 7 5 1 4 Convert UPC-A to EAN-13 – The scanner converts UPC-A to EAN-13 by transmitting a leading zero before the bar code. ³ 1 0 7 5 0 4 * Do Not Convert UPC-A to EAN-13 20

Transmit Lead Zero on UPC-E – This option will

transmit a zero before each UPC-E bar code. ³ 1 0 7 5 0 3 Do Not Transmit Lead Zero on UPC-E ³ 1 0 7 5 1 2 Convert EAN-8 to EAN-13 – The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13. ³ 1 0 7 5 0 2 * Do Not Convert EAN-8 to EAN-13 21

Numeric Keypad + (Plus)

01H SOH Num Lock 02H STX Down Arrow 03H ETX Numeric Keypad - (Minus) 04H EOT Insert 05h ENQ Delete 06H ACK System Request 07H BEL  (Right Arrow) 08H BS  (Left Arrow) 09H TAB Tab 0AH LF Caps Lock 0BH VT Shift Tab 0CH FF Left Alt 0DH CR Enter 0EH SO Left Control OFH SI Up Arrow 10H DLE F1 11H DC1 F2 12H DC2 F3 13H DC3 F4 14H DC4 F5 15H NAK F6 16H SYN F7 17H ETB F8 18H CAN F9 19H EM F10 1AH SUB Home 1BH ESC Esc 1CH FS Page Up 1DH GS Page Down 1EH RS Print Screen 1FH US End 22

Code Bytes Usage

The scanner must be in Configuration Mode for the features requiring code bytes for configuration. The Enter/Exit Configuration Mode bar code must be scanned before starting the configuration cycle. User configurable prefix/suffix characters can then be saved by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes. Example: To add an asterisk (*) as a Prefix, scan the bar codes. 1. Enter/Exit Configuration Mode (3 beeps) 2. Configurable Prefix #1 (1 beep) 3. Code Byte 0 (1 beep) 4. Code Byte 4 (2 beeps) 5. Code Byte 2 (3 beeps) 6. Enter/Exit Configuration Mode (3 beeps) Code Bytes 0–9 ³ 0 Code Byte 0 ³ 1 Code Byte 1 ³ 2 Code Byte 2 ³ 3 Code Byte 3 ³ 4 Code Byte 4 ³ 5 Code Byte 5 ³ 6 Code Byte 6 ³ 7 Code Byte 7 Code Bytes Usage 22 23

Code Byte 8

³ 9 Code Byte 9 Reserved Codes ³ 9 9 9 9 8 8 ~ Enable Reserved Code ³ 9 9 9 9 8 7 ~ Disable Reserved Code Code Type Table Code Byte Code Types 004 UPC-A 002 UPC-E 003 EAN-8 005 EAN-13 080 Code 39 081 Codabar 082 Interleaved 2 of 5 083 Code 128 084 Code 93 091 MSI Plessey 092 Code 11 093 Airline 2 of 5 (15 digits) 094 Matrix 2 of 5 095 Telepen 096 UK Plessey 099 TRI-OPTIC 098 Standard 2 of 5 097 Airline (13 digits) 24

ASCII Reference Table

HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 000 NUL @ 01 001 SOH A 02 002 STX B 03 003 ETX C 04 004 EOT D 05 005 ENQ E 06 006 ACK F 07 007 BEL G 08 008 BS H 09 009 HT I 0A 010 LF J 0B 011 VT K 0C 012 FF L 0D 013 CR M 0E 014 SO N 0F 015 SI 0 10 016 DLE P 11 017 DC1 Q 12 018 DC2 R 13 019 DC3 S 14 020 DC4 T 15 021 NAK U 16 022 SYN V 17 023 ETB W 18 024 CAN X 19 025 EM Y 1A 026 SUB Z 1B 027 ESC [ 1C 028 FS \ 24 25

Code Byte Value

Character Control Keyboard Eqv 1D 029 GS ^ 1E 030 RS _ 1F 031 US 20 032 SP space,blank 21 033 ! 22 034 “ 23 035 # 24 036 $ 25 037 % 26 038 & 27 039 ‘ apostrophe 28 040 ( 29 041 ) 2A 042 * 2B 043 + 2C 044 , comma 2D 045 - minus 2E 046 . period 2F 047 / 30 048 0 number zero 31 049 1 number one 32 050 2 33 051 3 34 052 4 35 053 5 36 054 6 37 055 7 38 056 8 39 057 9 3A 058 : 3B 059 ; 26

Code Byte Value

Character Control Keyboard Eqv 3C 060 < less than 3D 061 = 3E 062 > greater than 3F 063 ? 40 064 @ shift P 41 065 A 42 066 B 43 067 C 44 068 D 45 069 E 46 070 F 47 071 G 48 072 H 49 073 I letter l 4A 074 J 4B 075 K 4C 076 L 4D 077 M 4E 078 N 4F 079 O letter O 50 080 P 51 081 Q 52 082 R 53 083 S 54 084 T 55 085 U 56 086 V 57 087 W 58 088 X 59 089 Y 26 27

Code Byte Value

Character Control Keyboard Eqv 5A 090 Z 5B 091 [ shift K 5C 092 \ shift L 5D 093 ] shift M 5E 094 ^ à,shift N 5F 095 _ ♣, shift 0, underscore 60 096 ‘ accent grave 61 097 a 62 098 b 63 099 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 I 6A 106 j 6B 107 k 6C 108 l 6D 109 m 6E 110 n 6F 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 28

Code Byte Value

Character Control Keyboard Eqv 79 121 y 7A 122 z 7B 123 { 7C 124 | vertical slash 7D 125 } alt mode 7E 126 ~ (alt mode) 7F 127 DEL delete, rubout Extended Key Code Reference Table Key At Scan Code PS2 Scan Code 3151 Prefix/Suffix Value Hex = Decimal  75H 48H 63H 80H = 128  72H 50H 60H 81H = 129  74H 4DH 6AH 82H = 130  6BH 4BH 61H 83H = 131 Insert 70H 52H 67H 84H = 132 Delete 71H 53H 64H 85H = 133 Home 6CH 47H 6EH 86H = 134 End 69H 4FH 00H 87H = 135 Page Up 7DH 49H 00H 88H = 136 Page Down 7AH 51H 00H 89H = 137 Right Alt 11H 38H 00H 8AH = 138 Right Ctrl 14H 1DH 39H 8BH = 139 Reserved 00H 00H 00H 8CH = 140 Reserved 00H 00H 00H 8DH – 141 Numeric Keypad Enter 5AH 1CH 79H 8EH = 142 Numeric Keypad/ 4AH 35H 00H 8FH = 143 F1 05H 3BH 07H 90H = 144 F2 06H 3CH 0FH 91H = 145 F3 04H 3DH 17H 92H = 146 F4 0CH 3EH 1FH 93H = 147 F5 03H 3FH 27H 94H = 148 F6 0BH 40H 2FH 95H = 149 F7 83H 41H 37H 96H = 150 28 29

Hex = Decimal

F8 0AH 42H 3FH 97H = 151 F9 01H 43H 47H 98H = 152 F10 09H 44H 4FH 99H = 153 F11 78H 57H 56H 9AH = 154 F12 07H 58H 5EH 9BH = 155 Numeric + 79H 4EH 00H 9CH = 156 Numeric - 7BH 4AH 7CH 9DH = 157 Numeric * 7CH 37H 00H 9EH = 158 Caps Lock 58H 3AH 14H 9FH = 159 Num Lock 77H 45H 00H A0H = 160 Left alt 11H 38H 00H A1H = 161 Left Ctrl 14H 1DH 11H A2H = 162 Left Shift 12H 2AH 12H A3H = 163 Right Shift 59H 36H 59H A4H = 164 Print Screen Multiple 00H 00H A5H = 165 Tab ODH OFH 0DH A6H = 166 Shift Tab 8DH 8FH 65H A7H = 167 Enter 5AH 1CH 5AH A8H = 168 ESC 76H 01H 08H A9H = 169 Left ALT Make 11H 36H 00H AAH = 170 Left ALT Break 11H B6H 00H ABH = 171 Left CTRL Make 14H 1DH 00H ACH = 172 Left CTRL Break 14H 9DH 00H ADH = 173 *Left ALT + 1 character 11H 36H 00H AEH = 174 *Left Crtl + 1 character 14H 1DH 00H AFH = 175 *Send 58H C0H = 192 Clear 6FH C1H = 193 Jump 76H C2H = 194 Send Line 7EH C3H = 195 Erase EOF 6DH C4H = 196 Send - Make Only 58H C5H = 197 * Example: 1st Configurable Prefix = 174 2nd Configurable Prefix = 065 Scanner will transmit “A” 30

Seller warrants its products to be free from defects in materials and workmanship

and to conform to seller’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any seller product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A) modification or alteration by the purchaser or other party, (B) excessive voltage or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the product by anyone other than seller or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by seller for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to seller factory or authorized service center for inspection. No product will be accepted by seller without a Return Materials Authorization, which may be obtained by contacting seller. In the event that the product is returned to seller or its authorized service center within the Warranty Period and seller determines to its satisfaction that the product is defective due to defects in materials or workmanship, seller, at its sole option, will either repair or replace the product without charge, except for return shipping to seller. EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NON- INFRINGEMENT. SELLER’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO EVENT SHALL SELLER BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF SELLER ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER (WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL AMOUNT PAID TO SELLER FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN SELLER MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. Limited Warranty 31

All provisions of this Limited Warranty are separate and severable, which means

that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. Seller extends these warranties only to the first end-users of the products. These warranties are non-transferable. The duration of the limited warranty is 90 days.

Other Barcode Reader Manuals