Metrix MX 23 Operation & User’s Manual

File Specifications

Brand: Metrix
Category: Multimeter
Model: MX 23 (Operation & User’s Manual), prrwLQ5SQiUP.
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 19 pages

Download PDF

Download Metrix MX 23 Manual (19 pages)

Read Online:

Read the Metrix MX 23 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Portable digital multimeters

5.2.10. Environment Reference temperature : 23°C ± 5°C Limit range of operation : 0°C to 40°C Rated range of use : -10°C to 55°C Storage temperature range : -20°C to 70°C Temperature coefficient : max. 0.1 x (accuracy) / K • additional error in Ω : 50 D from -5°C to 0°C • frequency sensitivity : max. 0.3 x (sensitivity) / K Relative humidity : 0 to 80 % from 0 to 35°C (70 % max. for 5 / 50 MΩ) 0 to 70 % from 35°C to 50°C Protection rating : IP 40 Max. influence in electro-magnetic fields acc. to NF EN 61000-4-3 Sept 06: from 80 ...

Portable digital multimeters

23 3.4.3. Replacing the battery or fuses (except MX 23)  Caution ! Disconnect test leads from any circuit under test, turn the meter off and remove test leads from the input terminals . Use the following procedure: 1 - Disconnect test leads from any inputs terminals 2 - Using a appropriate tool, make slide the case bottom of the instrument 3 - Replace the battery or fuse (respect the value and the type). 4 - Replace the immovable part.  Fitting the fuses : Those fuses are correctly fitted ; those ones are not. 3.4.4. Cleaning Clean the instrument usi ...

Portable digital multimeters

4. FUNCTIONAL DESCRIPTION 4.1. RANGE / AC+DC key The RANGE key is operative in following positions of the selector switch : VLOW Z, VAC+DC, VDC, Ω, . This key makes it possible : • In AUTO (Autoraging) mode to switch to MANUAL mode (short press). • In MANUAL mode, to select the next range (short press) or return to AUTO mode (long press), the AUTO sign appears on the display. This can be used to switch on the multimeter again after an automatic shutdown. It can also be used to access secondary functions associated with the selector switch posit ...

Portable digital multimeters

23 3.4.3. Replacing the battery or fuses (except MX 23)  Caution ! Disconnect test leads from any circuit under test, turn the meter off and remove test leads from the input terminals . Use the following procedure: 1 - Disconnect test leads from any inputs terminals 2 - Using a appropriate tool, make slide the case bottom of the instrument 3 - Replace the battery or fuse (respect the value and the type). 4 - Replace the immovable part.  Fitting the fuses : Those fuses are correctly fitted ; those ones are not. 3.4.4. Cleaning Clean the instrument usi ...

Portable digital multimeters

USER’S MANUAL CONTENTS 1. GENERAL INSTRUCTIONS ..........................................................................................17 1.1. Symbols used on the instrument .............................................................................17 1.2. Precautions and safety measures ...........................................................................17 1.3. Safety features.........................................................................................................18 1.4. Protection devices ................................ ...

Portable digital multimeters

29 5.2.8. Frequencies Selector switch position Ranges Accuracy Input impedance Protection Resolution 0.62 to 5 Hz 0.0001 Hz 5 to 50 Hz 0.001 Hz 50 to 500 Hz 0.01 Hz 500 to 5 kHz 0.1 Hz 5 to 50 kHz 0.03 % R + 2 D 1 Hz FREQ 50 to 500 kHz 0.05 % R + 1 D 10 MΩ 600 VRMS 10 Hz Number of count : 5000 / 50 000 Range selection : automatic The frequency is based on 5000 count. With the "Range" button, it is based on 50 000 count.  Warning : time measurement [50 000 count] = 10 x measurement time [5000 count] Frequency band Sinus Square 10 Hz to 100 kHz 100 mVe ...

Portable digital multimeters

31 5.3. Accessories 5.3.1. Supplied with the multimeter 1 set of test leads with safety probes AG0475AZ 1 6LF22 9 V battery P01100620 1 user’s manual 1 verification certificate 1 protective elastomer case AE0237 1 carrying case 280 x 210 x 80 with foam (with some models only) 5.3.2. Optional Measuring accessories Set of accessories for electronics P01101894 Set of accessories for electricity P01101895 Probes CA801, TC K temperature adapter, 1 channel, 1 mV/°C P 01652401Z CA802, TC K temperature adapter, 2 channels, 1 mV/°C with differential m ...

Metrix MX 23 user guide recommended for: ScopiX IV, MTX 3292, MTX 1032-B, MX 350, MTX 202.

⚠️ Download Safety

The Multimeter Operation & user’s manual (19 pages) is completely safe to download (last scan date: 11/01/2026).