OHAUS SD35 Operation & User’s Manual

Text of the manual

This product conforms to the EMC Directive 89/336/EEC and the Low

Voltage Directive 73/23/EEC. The complete Declaration of Conformity is available from Ohaus Corporation.

In conformance with the European Directive 2002/96 EC on Waste Electrical and Elec-

tronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfer- ence by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con- nected. • Consult the dealer or an experienced radio/TV technician for help Industry Canada Note This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. EMC Australia / New Zealand: AS/NZS4251.1, AS/NZS4252.1 ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veri- tus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard’s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard. Registro ISO 9001 En 1994, Bureau Veritus Quality International (BVQI) le otorgó a Ohaus Corporation, EE.UU., un certifi- cado de registro ISO 9001 el cual confirma que el sistema administrativo de calidad de Ohaus cumple con los requerimientos del estándar ISO 9001. En mayo 15 del 2003, Ohaus Corporation, EE.UU., fue registrada nuevamente al estándar ISO 9001:2000. Enregistrement ISO 9001 En 1994, le Bureau Veritus Quality International (BVQI) a octroyé la certification d’enregistrement ISO 9001 à Ohaus Corporation, États-Unis d’Amérique, confirmant que le système de gestion de la qualité Ohaus était conforme aux conditions normalisées de l’ISO 9001. Le 15 mai 2003, Ohaus Corporation, États-Unis d’Amérique, a été ré-enregistrée à la norme ISO 9001:2000. Registrierung nach ISO 9001 Im Jahr 1994 wurde der Ohaus Corporation, USA, ein Zertifikat der Registrierung nach ISO 9001 vom Bureau Veritus Quality International (BVQI) verliehen, in dem bestätigt wird, dass das Ohaus-Qualitäts- managementsystem den Anforderungen der Norm ISO 9001 entspricht. Am 15. Mai 2003 wurde die Ohaus Corporation, USA, gemäß der Norm ISO 9001:2000 neu registriert. Registrazione ISO 9001 Nel 1994, Ohaus Corporation, USA, ha ricevuto il certificato di registrazione ISO 9001 da Bureau Veritus Quality International (BVQI), come conferma che il sistema di gestione della qualità Ohaus risponde alle caratteristiche standard di ISO 9001. Il 15 Maggio 2003, Ohaus Corporation, USA, è stata riregistrata per la normativa ISO 9001:2000.

SD SERIES BENCH SCALE EN-1

Ohaus SD Series Bench Scale INSTRUCTION MANUAL • The contents of this manual applies to all models of the SD Series Bench Scale. • Calibration weights are not provided with this product. • For best results, use the product within the specified operating temperature range. • For best accuracy, perform your measurements in a clean environment, free of electrostatic and magnetic fields, dust and dirt, moisture, vibration and air currents. • Use your SD Series Bench Scale with care, gently loading items to be weighed on the center of the platform. Avoiding rough treatment will aid in extending the life of your Scale.

EN-2 SD SERIES BENCH SCALE

Introduction This manual covers operation for the Ohaus SD Series Bench Scales. Unpacking SD Series Bench Scale is shipped with the following components: • Indicator • AC Power Adapter • Scale Base • This Instruction Manual • Mounting Brackets • Warranty Card Leveling Scale Platform The Scale Base should be placed on a level, stable surface before operation. Models SD75L and SD200L are equipped with adjustable leveling feet. Adjust the four leveling feet under the platform to level it. Power Options AC Adapter Operation • The AC Adapter (included) may be used to power the system when battery power is not available. • Check that the AC input power as marked on the Adapter matches the available power source. • Connect the round plug of the AC Adapter to the power input jack at the side of the Indicator housing. See Figure 1. • Plug the AC Adapter into an AC power outlet. Figure 1. Connecting Adapter Plug to Indicator.

SD SERIES BENCH SCALE EN-3

Battery Installation (Optional) • Open the battery cover on the bottom of the Indicator and install three “C” size (LR14) alkaline batteries into the compartment. Orient the batteries as shown on the inside cover. Close the battery cover. NOTE: Batteries are not included. Figure 2. Battery Installation. CAUTION: Do not dispose of used batteries in domestic waste. Follow the proper disposal or recycling requirements in accordance with local laws and regulations. Indicator Mounting and Placement Options • Table Top Placement: The Indicator may be placed on a flat table surface without additional hardware. Four rubber feet provide reduced slippage on most surfaces. • Direct Wall Mounting: The Indicator may be mounted directly to a wall using two screws (not included). Select appropriate size screws that fit into the holes at the bottom of the Indicator housing. See Figure 3. When mounting to a wall without a solid backing, use appropriate anchoring hardware.

EN-4 SD SERIES BENCH SCALE

Figure 3. Direct Wall Mount Arrangement. • Bracket Wall Mounting/Table Mounting: Attach the two mounting brackets as shown in Figure 4. Position the Indicator where desired on the wall or table. Install 2 screws (not supplied) into the ends of each bracket to secure them to the surface. When mounting to a wall without solid backing, use appropriate anchoring hardware. MOUNTING NOTES: 1. When attaching brackets: Insert round pins into holes at bottom of Indicator, slide each bracket back to lock in place. 2. Mounting brackets may be attached in two different orientations to provide optimum viewing angle. 3. Some mounting positions may require that the brackets be attached to the work surface before being attached to the indicator. Figure 4. Bracket Wall & Table Mount Arrangements. 120mm / 4.72” 120mm / 4.72” 90mm / 3.54”

SD SERIES BENCH SCALE EN-5

Product Features & Operation Figure 5. Indicator Panel Controls. Two Button Keypad • ON/ZERO Off : A short press turns on the scale when it is off. When the scale is on, a short press zeroes the scale, and a long press turns the scale off. • UNITS Cal : A short press changes the weighing unit and weighing mode. A short press initiates countdown during Dynamic Weighing Mode. A long press initiates the calibration process. Display Window • Large 7-Segment Numeric Characters: Weight (mass) values are shown using 4 digits including negative sign and decimal places. Prompts for calibration and possible error conditions are also shown using these digits. • Stable Reading Indication: A * will appear in the lower left corner of the display to indicate when the reading is stable. • Weighing Unit Indication: The weighing unit selected appears on the right side of the display. • Dynamic Weighing Mode Indication: A • will flash next to the selected unit during this mode. SD

EN-6 SD SERIES BENCH SCALE

• Low Battery Indication: The battery symbol on the left side of the display indicates a low battery condition. When first displayed , approximately 12 hours of operation remain. When the battery is fully depleted, the scale will momentarily display “Lo bAt” and shut off. Operation • Power Up Test: When the ON/ZERO Off button is pressed, the scale is turned on, all display segments will appear for a short time, followed by the software version. The display will then reset to zero. • Zero Function: By pressing the ON/ZERO Off button, the scale display returns to zero. When adding additional mass, the ON/ZERO Off button may be used repeatedly until the full capacity of the scale is reached. When a container is used, the ON/ZERO Off button may be used to simulate a Tare function. Additional mass may then be added as a NET weight. When removing both the sample and container from the scale, a negative value may be displayed. Zero the scale again before subsequent usage. NOTE: The ON/ZERO Off button will perform a true zero setting function when displayed values are within +2% of full capacity. Above 2%, the range is limited to full capacity by subtraction. • Negative Values: When a load is removed from the scale, any previously zeroed value will be displayed as a negative number. To return to normal operation, the negative value is cleared from the display by pressing the ON/ZERO Off button. • Overload: If the applied load exceeds the capacity of the scale, an “E” is displayed. Remove the load and the scale will return to normal operation.

SD SERIES BENCH SCALE EN-7

• Auto Shut-Off: To extend battery life, the scale will automatically turn off after approximately four minutes of inactivity. This feature is only active during battery operation. Dynamic Weighing 1. With platform empty, press the UNITS Cal button until the indicator • flashes next to the desired measuring unit. 2. Place a mass on the platform. The scale will show “-A-”. NOTE: If using a container, press ON/ZERO Off to tare the weight and return to zero. 3. With a mass on the platform or container, a short press of UNITS Cal will start the averaging countdown from 5 seconds. 4. The averaged weight is then displayed. The indicator • stops flashing when the process is complete. 5. The display will hold until a button is pressed. 6. To repeat the process press UNITS Cal with a mass on the platform or container. 7. To Exit, remove the mass from the platform or container and press UNITS Cal.

EN-8 SD SERIES BENCH SCALE

Calibration For best results, calibrate the scale at regular intervals. (Calibration weights are not supplied with the scale.) CAUTION USE EXTREME CARE WHEN HANDLING CALIBRATION WEIGHTS AS THEY ARE VERY HEAVY. IMPROPER LIFTING METHODS OR MISUSE OF CALIBRATION WEIGHTS MAY RESULT IN PERSONAL INJURY. MULTIPLE WEIGHTS MAY BE USED TO EQUAL THE REQUIRED CALIBRATION WEIGHT. 1. Allow the scale to warm up and stabilize for a least two minutes before commencing the calibration procedure. 2. To select the weighing unit to be used for calibration, press the UNITS Cal button until the correct unit is displayed. NOTE: The calibration process can be stopped at any time by pressing the UNITS Cal button or by turning the scale off. The correct span calibration weights will need to be available before starting the calibration (see specification table). Calibration is unavailable in Dynamic Weighing Mode. 3. Press and hold the UNITS Cal button until “CAL” is displayed. 4. With the platform empty, press the ON/ZERO Off button to capture the scale zero. The display will show “-C-”

SD SERIES BENCH SCALE EN-9

5. After the zero is captured, the required span calibration weight in the selected unit is displayed. 6. Place the calibration weight on the platform and press ON/ZERO Off button. The display will again show “-C-”. 7. After span capture, the display will return to the normal weighing mode. NOTE: The message “CAL E” will appear if an incorrect calibration weight was applied. Repeat the procedure using the correct calibration weight. Calibration Locking: By use of an internal switch, the calibration function may be locked (disabled), and unauthorized recalibration prevented. 1. With the scale powered off, remove the back housing section of the indicator by unscrewing the four screws at the bottom. 2. Slide the switch on the PCB (marked SW3) to the position marked “CAL LOCK”. 3. Reassemble the housing. 4. If required, place tamper evident sealing labels over the screw holes or over the housing edges. If later recalibration is required, the housing will need to be reopened and the lock switch returned to the original position. NOTE: When the lock switch is set to the CAL LOCK position, the power-on zero range is reduced to 10% of full capacity.

EN-10 SD SERIES BENCH SCALE

Model SD35 SD75 SD200 Capacity x Readability 35 x 0.02kg 77 x 0.05lb 75 x 0.05kg 165 x 0.1lb 200 x 0.1kg 440 x 0.2lb Weighing Units kg, lb Modes Simple Weighing, Dynamic Weighing Calibration Weights 25kg/50lb 50kg/100lb 100kg/200lb Stabilization Time Within 3 seconds Zero Range To capacity by subtraction Maximum Overload 150% Error Indications: “E” “CALE” “UnSt” “ErrE” “Lo bat OFF” “Lo Line OFF” - Over load, Under load, Power on Over/Under load - Calibration Error - Unstable at Power on - Memory Error - Low battery shut down - Low line voltage shut down (Power Adapter) Underload Indication Negative value Auto Shut-Off 4 minutes no activity (battery operation only) Battery Operating Time 360 hours Operating Temperature Range 41° to 104° F / 5° to 40°C at 10% to 80% relative humidity, non-condensing Cable Length 1.8m / 72” (uncoiled) Display 4 Digit, LCD, 0.8”/20mm high Scale Base Size 316mm L x 280mm W x 45mm H / 12.4” x L x 11” W x 1.77” H Indicator Size 210mm L x 91mm W x 39mm H / 8.27” L x 3.58” W x 1.54” H Battery power requirements 3 “C” Alkaline batteries (LR14) AC Adapter 9-12 Volt DC, 100mA Net Weight 2.6kg / 5.8lb 3.3kg / 7.3lb Shipping Weight 3.7kg / 8.1lb 4.3kg / 9.5lb Shipping Carton Size 380mm L x 100mm W x 465mm H / 15” L x 3.94” W x 18.3” H Specifications (Standard Base Models)

SD SERIES BENCH SCALE EN-11

Model SD75L SD200L Capacity x Readability 75 x 0.05kg 165 x 0.1lb 200 x 0.1kg 440 x 0.2lb Weighing Units kg, lb Modes Simple Weighing, Dynamic Weighing Calibration Weights 50kg/100lb 100kg/200lb Stabilization Time Within 3 seconds Zero Range To capacity by subtraction Maximum Overload 150% Error Indications: “E” “CALE” “UnSt” “ErrE” “Lo bat OFF” “Lo Line OFF” - Over load, Under load, Power on Over/Under load - Calibration Error - Unstable at Power on - Memory Error - Low battery shut down - Low line voltage shut down (Power Adapter) Underload Indication Negative value Auto Shut-Off 4 minutes no activity (battery operation only) Battery Operating Time 360 hours Operating Temperature Range 41° to 104° F / 5° to 40°C at 10% to 80% relative humidity, non-condensing Cable Length 1.8m / 72” (uncoiled) Display 4 Digit, LCD, 0.8”/20mm high Scale Base Size 520mm L x 400 mm W x 75 mm H / 20.5” L x 15.7” W x 3” H Indicator Size 210mm L x 91mm W x 39mm H / 8.27” L x 3.58” W x 1.54” H Battery power requirements 3 “C” Alkaline batteries (LR14) AC Adapter 9-12 Volt DC, 100mA Net Weight 14kg / 31lb Shipping Weight 15.5kg / 34lb Shipping Carton Size 600mm L x 480mm W x 230mm H / 24” L x 19” W x 9” H Specifications (Large Base Models)

EN-12 SD SERIES BENCH SCALE

Figure 6. Scale Base Overall Dimensions. 53mm /2.09” 69mm / 2.72” 39mm / 1.54” 210mm / 8.27” 91mm / 3.58” 280mm / 11.02” 45mm / 1.77” Figure 5. Indicator Overall Dimensions, Available Viewing Angles. 0º 50º 70º Standard Base Large Base 316mm / 12.44” 400 mm / 15.7” 520mm / 20.5” 75mm / 3”

SD SERIES BENCH SCALE EN-13

LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship for duration of the warranty. During the warranty period Ohaus will repair, or, at its option, replace any components) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of product registration, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details.