suprema bioentry PLUS Installation Manual
Text of the manual
IP based Fingerprint Access Control
www.supremainc.com
EN 101.00.BEP V1.22
ⒸCopyright 2007 Suprema Inc.
Contents
Safety precautions
3
Basics of fingerprint recognition
5
How to place a finger
6
Product Contents
8
Front Side
10
Bottom and Back Side
11
Product Dimension
12
Cables and Connectors
13
Installation of Wall-mount Bracket
14
Power Connection
15
Ethernet Connection
16
RS485 Connection
18
Relay Connection
20
Digital Input Connection
23
Wiegand Output
25
Network Default Setting 26
Installation Reference
27
Electrical Specification
30
Troubleshooting
31
Device cleaning
32
FCC Rules
33
Specifications 34
ⒸCopyright 2007 Suprema Inc.
Safety precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not install the device in a
place subject to direct sun light,
humidity, dust or soot.
Do not place a magnet near the pr
oduct. Magnetic objects such as
magnet, CRT, TV, monitor or spe
aker may damage the device.
Do not place the device next to
heating equipments.
Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.
Clean the device often to remove
dust on it.
In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.
ⒸCopyright 2007 Suprema Inc.
Safety precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before
use.
Do not drop the device.
Do not damage the device.
Do not disassemble, repair or
alter the device.
Do not let children touch the
device without supervision.
Do not use the device for any
other purpose than specified.
Contact your nearest dealer in
case of a trouble or problem.
ⒸCopyright 2007 Suprema Inc.
Basics of fingerprint recognition
What is fingerprint recognition?
Fingerprint is an individual’s own biometric information and does not change throughout his/her life.
Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint
information.
Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security
systems replacing PIN or cards.
Process of fingerprint recognition
Fingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while
valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys
and finger recognition makes use of such originality and uniqueness of these patterns.
Fingerprint sensor generates 2-dimentional fingerprint image using different technology. According
to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal.
Fingerprint template is a collection of numeric data representing the features of a fingerprint.
Fingerprint templates are saved inside the memory of BioStation and used for identification.
Secure way to protect personal information
To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is
impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data
of the features of a fingerprint.
ⒸCopyright 2007 Suprema Inc.
How to place a finger
Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint
skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal
fingerprint recognition performance.
Select a finger to enroll
It is recommended to use an index finger or a middle finger.
Thumb, ring or little finger is relatively more difficult to place in a correct position.
How to place a finger on a sensor
Place a finger such that it completely covers the sensor area with maximum contact.
Place core part of a fingerprint to the center of a sensor.
People tend to place upper part of a finger.
The core of a fingerprint is a center where the spiral of ridges is dense.
Usually core of fingerprint is the opposite side of the lower part of a nail.
Place a finger such that the bottom end of a nail is located at the center of a sensor.
If a finger is placed as in the right picture, only a small area of a finger is captured. So it is
recommended to place a finger as shown in the left picture.
ⒸCopyright 2007 Suprema Inc.
How to place a finger
Tips for different fingerprint conditions
Suprema’s fingerprint products are designed to scan fingerprint smoothly regardless of the
conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please
refer to the followings tips.
If a finger is stained with sweat or water, scan after wiping moisture off.
If a finger is covered with dust or impurities, scan after wiping them off.
If a finger is way too dry, place after blowing warm breath on the finger tip.
Tips for fingerprint enrollment
In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please
try to place a finger correctly with care.
In case of low acceptance ratio, the following actions are recommended.
Delete the enrolled fingerprint and re-enroll the finger.
Enroll the same fingerprint additionally.
Try another finger if a finger is not easy to enroll due to scar or worn-out.
For the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is
recommended to enroll more than two fingers per user.
ⒸCopyright 2007 Suprema Inc.
Product Contents
Basic Contents
BioEntry Plus
Wall-mounting metal bracket
Wall mounting screws – 2 ea
Star-shaped screws
Star-shaped small wrench
3 pin, 4 pin, 5 pin, 7 pin cables – each 1 ea
Software CD
Diode
(1 EA)
ⒸCopyright 2007 Suprema Inc.
Product Contents
Optional accessories
USB fingerprint scanner
for enrollment on PC
12V power adaptor
Plastic stand
Secure I/O
ⒸCopyright 2007 Suprema Inc.
Front
Front Side
RF card reading part
Place an RF card over the
picture
LED
Display current status using
seven different colors
Fingerprint sensing part
Place a finger on a sensor
surface
LED Status per Color
Green : Authorization Success
Red : Authorization Fail
Pink : On Processing
Flicker Blue/Sky-Blue Color per 2sec : Normal
Flicker Red/Pink Color per 2sec : Locked
Flicker Blue/Red Color per 2sec : Initialized
Time due to the Internal Battery Discharge
Flicker Blue/Yellow Color per 2sec : DHCP
Fail
Flicker Red Color per 2sec : Failed. Please
contact to your distributor or Suprema
Flicker Yellow Color per 2sec : Waiting Input
Flicker Yellow Color per 1sec : Receiving IP
Address from DHCP server
ⒸCopyright 2007 Suprema Inc.
Bottom and Back Side
Bottom
Back
Star-shaped screw hole for fixing a body to a metal bracket
3 pin connector – wiegand input or wiegand output
5 pin connector – power and RS485
4 pin connector – ethernet (TCP/IP)
7 pin connector – digital input and relay output
DIP switch : RS485 termination setting
(Refer to “RS485 Connection” pages for details)
Network default setting
(Refer to “Network Default Setting” pages for details)
ⒸCopyright 2007 Suprema Inc.
Product Dimension
Metal Bracket
Front
Side
160
50
37
150
40
135
(unit : mm)
160
ⒸCopyright 2007 Suprema Inc.
Cables and Connectors
Power and RS485
TCP/IP
Wiegand In/output (Switchable)
Digital Inputs and Relay output
PIN
PIN DESCRIPTION
WIRE
1
WIEGAND DATA0
GREEN
2
WIEGAND DATA1
WHITE
3
WIEGAND GND
BLACK
PIN
PIN DESCRIPTION
WIRE
1
POWER +12V
RED
2
POWER GND
BLACK
3
RS -485 GND
GRAY
4
RS -485 TRX+
BLUE
5
RS -485 TRX-
YELLOW
PIN
PIN DESCRIPTION
WIRE
1
SW1 INPUT
YELLOW
2
SW1 GND
BLACK
3
SW2 INPUT
GREEN
4
SW2 GND
BLACK
5
RELAY NORMAL CLOSE
ORANGE
6
RELAY COMMON
BLUE
7
RELAY NORMAL OPEN
WHITE
PIN
PIN DESCRIPTION
WIRE
RJ45 PIN
1
TX +
YELLOW
6
2
TX -
GREEN
3
3
RX +
RED
2
4
RX -
BLACK
1
ⒸCopyright 2007 Suprema Inc.
Installation of Wall-mount Bracket
Fix wall mount bracket on a wall using wall mounting
screws
Hook BioEntry Plus on the wall mount bracket
Fix BioStation and wall mounting bracket using a star
shape screw.
Wall mounting
screws
Star-shaped
screw
Star-shaped
wrench
ⒸCopyright 2007 Suprema Inc.
Power Connection
Recommended power supply
12V ± 10%, at least 500mA.
Comply with standard IEC/EN 60950-1.
To share the power with other devices, use a power supply with higher current ratings.
BioEntry Plus
(5) TRX- (Yellow)
(4) TRX+ (Blue)
(3) Signal GND (Gray)
(2) Power GND (Black)
(1) Power 12V (Red)
RS-485
DC
Power supply
UPS
(optional)
ⒸCopyright 2007 Suprema Inc.
Ethernet Connection (Direct connection with PC)
To connect BioEntry Plus with a PC directly, connect both devices with a straight CAT-5
cable. As the BioEntry Plus supports auto MDI/MDIX feature, it is not necessary to use a
crossover type cable.
ⒸCopyright 2007 Suprema Inc.
RS485 Connection for Secure I/O
Max number of devices
Maximum numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry
Plus) and four(4) Secure I/Os
ⒸCopyright 2007 Suprema Inc.
Relay Connection – Fail safe lock
Deadbolt /
Door strike
DC
Power supply
+
-
+
-
BioEntry Plus
(7) Normally Open / N.O. (White)
(6) Common (Blue)
(5) Normally Closed / N.C. (Orange)
•
N.O. (Normally Open): A control signal closes the circuit.
•
N.C. (Normally Closed): A control signal opens the circuit.
•
Take care of the direction of the diode.
•
Make sure to install the diode near to the door lock.
•
Make sure to use different power supplies for the BioEntry Plus and the door lock.
•
Make sure to install the diode at both ends of the circuit as shown in the figure above in order to protect the relay contact from the reverse current that
occurs when the door lock works.
ⒸCopyright 2007 Suprema Inc.
Relay Connection – Fail secure lock
Deadbolt /
Door strike
DC
Power supply
+
-
+
-
BioEntry Plus
(7) Normally Open / N.O. (White)
(6) Common (Blue)
(5) Normally Closed / N.C. (Orange)
•
Normally Open/N.O: When no control signal is received, the electricity does not flow. When control signals are received, the electricity continues
flowing.
•
Normally Close/N.C: When no control signal is received, the electricity continues flowing. When control signals are received, the electricity does not
flow.
•
Take care of the direction of the diode.
•
Make sure to install the diode near to the door lock.
•
Make sure to use different power supplies for the BioEntry Plus and the door lock.
•
Make sure to install the diode at both ends of the circuit as shown in the figure above in order to protect the relay contact from the reverse current that
occurs when the door lock works.
ⒸCopyright 2007 Suprema Inc.
Relay Connection - Automatic door
BioEntry Plus
Automatic
Door
(7) Normally Open / N.O. (White)
(6) Common (Blue)
(5) Normally Closed / N.C. (Orange)
Door
Controller
RTE Switch
Presence
Detector
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (RTE, Door sensor)
Door Status
BioEntry Plus
(1) SW0 Input (Yellow)
(2) SW0 GND (Black)
(3) SW1 Input (Green)
(4) SW1 GND (Black)
Request To
Exit
ⒸCopyright 2007 Suprema Inc.
Digital Input Connection (Alarm, Emergency sw)
Switch #1
BioEntry Plus
(1) SW0 Input (Yellow)
(2) SW0 GND (Black)
(3) SW1 Input (Green)
(4) SW1 GND (Black)
Switch #0
ⒸCopyright 2007 Suprema Inc.
Network Default Setting
In case of forgetting network setting of BioEntry Plus (TCP/IP or RS-485 setting) during
installation or using BioEntry Plus, user can initialize network setting (TCP/IP or RS-485
setting) by using DIP SW installed on the back panel of BioEntry Plus. Please refer to the
figures in below.
How to initialize Network Setting
1. Turn off BioEntry Plus power.
2. Please make DIP SW #2 “ON” (Please refer to Fig.1)
3. After turning on BioEntry Plus power, user can modify
TCP/IP or RS-485 setting what user wants.
4. Please modify TCP/IP or RS-485 setting and save it.
4. Please make DIP SW #2 “OFF” (Please refer to Fig.2)
5. After recycling BioEntry Plus power, please check the
modified TCP/IP or RS-485 setting.
1
2
O
N
1
2
O
N
1
2
O
N
1
2
O
N
Network Default Setting
- TCP/IP Address : 192.168.0.1
- Not checked “Use Server”
- RS-485 : PC Connection, 115200bps
ⒸCopyright 2007 Suprema Inc.
Installation Reference 1 - Stand alone
Door Lock
Door Sensor
Exit Button
Enroll Scanner
PC
LAN
BioEntry Plus
ⒸCopyright 2007 Suprema Inc.
Installation Reference 2 – Secure
Exit Button
Enroll Scanner
PC
LAN
BioEntry Plus
RS485
Secure I/O
Door Sensor
Door Lock
ⒸCopyright 2007 Suprema Inc.
Installation Reference 3 – Network
Door Zone 2 (Anti passback)
Door Zone 1 (Anti passback)
BioStation
BioEntry Plus
BioEntry Plus
Secure I/O
RS485
RS485
LAN
BioStation
Secure I/O
BioEntry Plus
Exit Button
PC Server
PC Client
PC Client
RS485
Enroll Scanner
ⒸCopyright 2007 Suprema Inc.
Electrical Specification
Min.
Typ.
Max.
Notes
Power
Voltage (V)
10.8
12
13.2
Use regulated DC power adaptor only
Current (mA)
-
250
Switch Input
VIH (V)
2.0
-
10.0
VIL (V)
-
-
0.4
Pull-up resistance (Ω)
-
4.7k
-
The input ports are pulled up with 4.7k resistors
TTL/Wiegand Output
VOH (V)
-
5
-
VOL (V)
-
0.8
-
Pull-up resistance (Ω)
-
4.7k
-
The outputs ports are open drain type, pulled up with 4.7k resistors
internally
Relay
Switching capacity (A)
-
-
1
0.3
30V DC
125V AC
Switching power
(resistive)
-
-
30W
37.5VA
DC
AC
Switching voltage (V)
-
-
110
125
DC
AC
ⒸCopyright 2007 Suprema Inc.
Troubleshooting
Fingerprint can not be read well or it takes too long.
Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
Retry after wiping off finger and fingerprint sensor with dry towel.
If a fingerprint is way too dry, blow on the finger and retry.
Fingerprint is entered but authorization keeps failing.
Check whether the user is restricted by door zone or time zone.
Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some
reason.
Authorized but door is not opened.
Check whether the time is set as lock time.
Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.
Device doesn’t operate though power is connected.
Check whether a device and a bracket is well connected to each other. If not, a tamper switch is
activated and the device doesn’t work.
ⒸCopyright 2007 Suprema Inc.
Device cleaning
Wipe out machine surface with dry towel or cloth.
In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with
dry towel.
Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and
fingerprint can’t be entered.
ⒸCopyright 2007 Suprema Inc.
FCC Rules
Caution
Warning
Information to User
Changes or modifications not expressly approved by the manufacturer responsible
for compliance could void the user's authority to operate the equipment.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limit of a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, user and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guaranteee that
interference will not occur in a particular installation; if this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1.
Reorient / Relocate the receiving antenna.
2.
Increase the separation between the equipment and receiver.
3.
Connect the equipment into an outlet on a circuit difference from that to
which the receiver is connected.
4.
Consult the dealer or an experienced radio/TV technician for help
ⒸCopyright 2007 Suprema Inc.
Specifications
Item
Specification
CPU
400MHz DSP
Fingerprint sensor
500dpi Optical / Capacitive sensor
User capacity
5000 users (10,000 templates)
Log capacity
50,000 events
Matching speed
Less than 1 second
Operation mode
Fingerprint, RF Card, RF card + Fingerprint
Network Interface
TCP/IP, RS485
Internal relay
Deadbolt, EM lock, door strike, automatic door
TTL I/O
2 inputs for exit switch and door sensor
Wiegand In/Out
1 Port (Wiegand Input or Wiegand Output is used according to the configuration.)
Sound and Interface
Multi-color LED and multi-tone buzzer
Rated Voltage
DC 12V (Min. 500mA and above)
(When sharing the power with a device such as electric door lock, enough power is
required considering the power requirement for the connected device.)
Card option
125kHz EM card (EM4100)
125kHz HID Proximity Card
13.56MHz Mifare Card
Size
50 x 160 x 37 mm (Width x Height x Depth)
Certified
KCC, CE, FCC
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
E-mail : [email protected]
Website : www.supremainc.com
Functions and specifications of the product are subject to changes without notice due to quality
enhancement or function update. For any inquiry on the product, please contact Suprema Inc.