suprema bioentry PLUS Installation Manual

Text of the manual

IP based Fingerprint Access Control

www.supremainc.com EN 101.00.BEP V1.22

ⒸCopyright 2007 Suprema Inc.

Contents Safety precautions 3 Basics of fingerprint recognition 5 How to place a finger 6 Product Contents 8 Front Side 10 Bottom and Back Side 11 Product Dimension 12 Cables and Connectors 13 Installation of Wall-mount Bracket 14 Power Connection 15 Ethernet Connection 16 RS485 Connection 18 Relay Connection 20 Digital Input Connection 23 Wiegand Output 25 Network Default Setting 26 Installation Reference 27 Electrical Specification 30 Troubleshooting 31 Device cleaning 32 FCC Rules 33 Specifications 34

ⒸCopyright 2007 Suprema Inc.

Safety precautions  The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not install the device in a place subject to direct sun light, humidity, dust or soot. Do not place a magnet near the pr oduct. Magnetic objects such as magnet, CRT, TV, monitor or spe aker may damage the device. Do not place the device next to heating equipments. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel.

ⒸCopyright 2007 Suprema Inc.

Safety precautions  The list below is to keep user’s safety and prevent any loss. Please read carefully before use. Do not drop the device. Do not damage the device. Do not disassemble, repair or alter the device. Do not let children touch the device without supervision. Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem.

ⒸCopyright 2007 Suprema Inc.

Basics of fingerprint recognition  What is fingerprint recognition? Fingerprint is an individual’s own biometric information and does not change throughout his/her life. Fingerprint recognition is a technology that verifies or identifies an individual using such fingerprint information. Free from the risk of theft or loss, fingerprint recognition technology is being widely used in security systems replacing PIN or cards.  Process of fingerprint recognition Fingerprint consists of ridges and valleys. Ridge is a flow of protruding skin in a fingerprint while valley is a hollow between two ridges. Each individual has different pattern of ridges and valleys and finger recognition makes use of such originality and uniqueness of these patterns. Fingerprint sensor generates 2-dimentional fingerprint image using different technology. According to the sensing technology, fingerprint sensors are classified into optical, capacitive, or thermal. Fingerprint template is a collection of numeric data representing the features of a fingerprint. Fingerprint templates are saved inside the memory of BioStation and used for identification.  Secure way to protect personal information To avoid privacy concern, Suprema’s fingerprint products do not save fingerprint images itself. It is impossible to reconstruct a fingerprint image from a fingerprint template which is just numeric data of the features of a fingerprint.

ⒸCopyright 2007 Suprema Inc.

How to place a finger Suprema’s fingerprint products show an outstanding recognition performance regardless of the user’s fingerprint skin condition or the way of fingerprint positioning. However, following tips are recommended to get more optimal fingerprint recognition performance.  Select a finger to enroll It is recommended to use an index finger or a middle finger. Thumb, ring or little finger is relatively more difficult to place in a correct position.  How to place a finger on a sensor Place a finger such that it completely covers the sensor area with maximum contact. Place core part of a fingerprint to the center of a sensor.  People tend to place upper part of a finger.  The core of a fingerprint is a center where the spiral of ridges is dense.  Usually core of fingerprint is the opposite side of the lower part of a nail.  Place a finger such that the bottom end of a nail is located at the center of a sensor. If a finger is placed as in the right picture, only a small area of a finger is captured. So it is recommended to place a finger as shown in the left picture.

ⒸCopyright 2007 Suprema Inc.

How to place a finger  Tips for different fingerprint conditions Suprema’s fingerprint products are designed to scan fingerprint smoothly regardless of the conditions of a finger skin. However, in case a fingerprint is not read well on the sensor, please refer to the followings tips.  If a finger is stained with sweat or water, scan after wiping moisture off.  If a finger is covered with dust or impurities, scan after wiping them off.  If a finger is way too dry, place after blowing warm breath on the finger tip.  Tips for fingerprint enrollment In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place a finger correctly with care. In case of low acceptance ratio, the following actions are recommended.  Delete the enrolled fingerprint and re-enroll the finger.  Enroll the same fingerprint additionally.  Try another finger if a finger is not easy to enroll due to scar or worn-out. For the case when an enrolled fingerprint cannot be used due to injury or holding a baggage, it is recommended to enroll more than two fingers per user.

ⒸCopyright 2007 Suprema Inc.

Product Contents  Basic Contents BioEntry Plus Wall-mounting metal bracket Wall mounting screws – 2 ea Star-shaped screws Star-shaped small wrench 3 pin, 4 pin, 5 pin, 7 pin cables – each 1 ea Software CD Diode (1 EA)

ⒸCopyright 2007 Suprema Inc.

Product Contents  Optional accessories USB fingerprint scanner for enrollment on PC 12V power adaptor Plastic stand Secure I/O

ⒸCopyright 2007 Suprema Inc.

 Front Front Side RF card reading part Place an RF card over the picture LED Display current status using seven different colors Fingerprint sensing part Place a finger on a sensor surface LED Status per Color  Green : Authorization Success  Red : Authorization Fail  Pink : On Processing  Flicker Blue/Sky-Blue Color per 2sec : Normal  Flicker Red/Pink Color per 2sec : Locked  Flicker Blue/Red Color per 2sec : Initialized Time due to the Internal Battery Discharge  Flicker Blue/Yellow Color per 2sec : DHCP Fail  Flicker Red Color per 2sec : Failed. Please contact to your distributor or Suprema  Flicker Yellow Color per 2sec : Waiting Input  Flicker Yellow Color per 1sec : Receiving IP Address from DHCP server

ⒸCopyright 2007 Suprema Inc.

Bottom and Back Side  Bottom  Back Star-shaped screw hole for fixing a body to a metal bracket 3 pin connector – wiegand input or wiegand output 5 pin connector – power and RS485 4 pin connector – ethernet (TCP/IP) 7 pin connector – digital input and relay output DIP switch : RS485 termination setting (Refer to “RS485 Connection” pages for details) Network default setting (Refer to “Network Default Setting” pages for details)

ⒸCopyright 2007 Suprema Inc.

Product Dimension Metal Bracket Front Side 160 50 37 150 40 135 (unit : mm) 160

ⒸCopyright 2007 Suprema Inc.

Cables and Connectors Power and RS485 TCP/IP Wiegand In/output (Switchable) Digital Inputs and Relay output PIN PIN DESCRIPTION WIRE 1 WIEGAND DATA0 GREEN 2 WIEGAND DATA1 WHITE 3 WIEGAND GND BLACK PIN PIN DESCRIPTION WIRE 1 POWER +12V RED 2 POWER GND BLACK 3 RS -485 GND GRAY 4 RS -485 TRX+ BLUE 5 RS -485 TRX- YELLOW PIN PIN DESCRIPTION WIRE 1 SW1 INPUT YELLOW 2 SW1 GND BLACK 3 SW2 INPUT GREEN 4 SW2 GND BLACK 5 RELAY NORMAL CLOSE ORANGE 6 RELAY COMMON BLUE 7 RELAY NORMAL OPEN WHITE PIN PIN DESCRIPTION WIRE RJ45 PIN 1 TX + YELLOW 6 2 TX - GREEN 3 3 RX + RED 2 4 RX - BLACK 1

ⒸCopyright 2007 Suprema Inc.

Installation of Wall-mount Bracket  Fix wall mount bracket on a wall using wall mounting screws  Hook BioEntry Plus on the wall mount bracket  Fix BioStation and wall mounting bracket using a star shape screw. Wall mounting screws Star-shaped screw Star-shaped wrench

ⒸCopyright 2007 Suprema Inc.

Power Connection  Recommended power supply 12V ± 10%, at least 500mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with higher current ratings. BioEntry Plus (5) TRX- (Yellow) (4) TRX+ (Blue) (3) Signal GND (Gray) (2) Power GND (Black) (1) Power 12V (Red) RS-485 DC Power supply UPS (optional)

ⒸCopyright 2007 Suprema Inc.

Ethernet Connection (Direct connection with PC)  To connect BioEntry Plus with a PC directly, connect both devices with a straight CAT-5 cable. As the BioEntry Plus supports auto MDI/MDIX feature, it is not necessary to use a crossover type cable.

ⒸCopyright 2007 Suprema Inc.

RS485 Connection for Secure I/O  Max number of devices Maximum numbers of devices in an RS485 loop are two(2) devices (BioStation or BioEntry Plus) and four(4) Secure I/Os

ⒸCopyright 2007 Suprema Inc.

Relay Connection – Fail safe lock Deadbolt / Door strike DC Power supply + - + - BioEntry Plus (7) Normally Open / N.O. (White) (6) Common (Blue) (5) Normally Closed / N.C. (Orange) • N.O. (Normally Open): A control signal closes the circuit. • N.C. (Normally Closed): A control signal opens the circuit. • Take care of the direction of the diode. • Make sure to install the diode near to the door lock. • Make sure to use different power supplies for the BioEntry Plus and the door lock. • Make sure to install the diode at both ends of the circuit as shown in the figure above in order to protect the relay contact from the reverse current that occurs when the door lock works.

ⒸCopyright 2007 Suprema Inc.

Relay Connection – Fail secure lock Deadbolt / Door strike DC Power supply + - + - BioEntry Plus (7) Normally Open / N.O. (White) (6) Common (Blue) (5) Normally Closed / N.C. (Orange) • Normally Open/N.O: When no control signal is received, the electricity does not flow. When control signals are received, the electricity continues flowing. • Normally Close/N.C: When no control signal is received, the electricity continues flowing. When control signals are received, the electricity does not flow. • Take care of the direction of the diode. • Make sure to install the diode near to the door lock. • Make sure to use different power supplies for the BioEntry Plus and the door lock. • Make sure to install the diode at both ends of the circuit as shown in the figure above in order to protect the relay contact from the reverse current that occurs when the door lock works.

ⒸCopyright 2007 Suprema Inc.

Relay Connection - Automatic door BioEntry Plus Automatic Door (7) Normally Open / N.O. (White) (6) Common (Blue) (5) Normally Closed / N.C. (Orange) Door Controller RTE Switch Presence Detector

ⒸCopyright 2007 Suprema Inc.

Digital Input Connection (RTE, Door sensor) Door Status BioEntry Plus (1) SW0 Input (Yellow) (2) SW0 GND (Black) (3) SW1 Input (Green) (4) SW1 GND (Black) Request To Exit

ⒸCopyright 2007 Suprema Inc.

Digital Input Connection (Alarm, Emergency sw) Switch #1 BioEntry Plus (1) SW0 Input (Yellow) (2) SW0 GND (Black) (3) SW1 Input (Green) (4) SW1 GND (Black) Switch #0

ⒸCopyright 2007 Suprema Inc.

Network Default Setting  In case of forgetting network setting of BioEntry Plus (TCP/IP or RS-485 setting) during installation or using BioEntry Plus, user can initialize network setting (TCP/IP or RS-485 setting) by using DIP SW installed on the back panel of BioEntry Plus. Please refer to the figures in below. How to initialize Network Setting 1. Turn off BioEntry Plus power. 2. Please make DIP SW #2 “ON” (Please refer to Fig.1) 3. After turning on BioEntry Plus power, user can modify TCP/IP or RS-485 setting what user wants. 4. Please modify TCP/IP or RS-485 setting and save it. 4. Please make DIP SW #2 “OFF” (Please refer to Fig.2) 5. After recycling BioEntry Plus power, please check the modified TCP/IP or RS-485 setting. 1 2 O N 1 2 O N 1 2 O N 1 2 O N Network Default Setting - TCP/IP Address : 192.168.0.1 - Not checked “Use Server” - RS-485 : PC Connection, 115200bps

ⒸCopyright 2007 Suprema Inc.

Installation Reference 1 - Stand alone Door Lock Door Sensor Exit Button Enroll Scanner PC LAN BioEntry Plus

ⒸCopyright 2007 Suprema Inc.

Installation Reference 2 – Secure Exit Button Enroll Scanner PC LAN BioEntry Plus RS485 Secure I/O Door Sensor Door Lock

ⒸCopyright 2007 Suprema Inc.

Installation Reference 3 – Network Door Zone 2 (Anti passback) Door Zone 1 (Anti passback) BioStation BioEntry Plus BioEntry Plus Secure I/O RS485 RS485 LAN BioStation Secure I/O BioEntry Plus Exit Button PC Server PC Client PC Client RS485 Enroll Scanner

ⒸCopyright 2007 Suprema Inc.

Electrical Specification Min. Typ. Max. Notes Power Voltage (V) 10.8 12 13.2 Use regulated DC power adaptor only Current (mA) - 250 Switch Input VIH (V) 2.0 - 10.0 VIL (V) - - 0.4 Pull-up resistance (Ω) - 4.7k - The input ports are pulled up with 4.7k resistors TTL/Wiegand Output VOH (V) - 5 - VOL (V) - 0.8 - Pull-up resistance (Ω) - 4.7k - The outputs ports are open drain type, pulled up with 4.7k resistors internally Relay Switching capacity (A) - - 1 0.3 30V DC 125V AC Switching power (resistive) - - 30W 37.5VA DC AC Switching voltage (V) - - 110 125 DC AC

ⒸCopyright 2007 Suprema Inc.

Troubleshooting  Fingerprint can not be read well or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust Retry after wiping off finger and fingerprint sensor with dry towel. If a fingerprint is way too dry, blow on the finger and retry.  Fingerprint is entered but authorization keeps failing. Check whether the user is restricted by door zone or time zone. Inquire of administrator whether the enrolled fingerprint has been deleted frin the device for some reason.  Authorized but door is not opened. Check whether the time is set as lock time. Check whether an antipass back mode is in use. In antipass back mode, only who entered can exit.  Device doesn’t operate though power is connected. Check whether a device and a bracket is well connected to each other. If not, a tamper switch is activated and the device doesn’t work.

ⒸCopyright 2007 Suprema Inc.

Device cleaning  Wipe out machine surface with dry towel or cloth.  In case there is dust or impurities on the sensor of the BioStation, wipe off the surface with dry towel.  Note that if the sensor is cleaned by detergent, benzene or thinner, surface is damaged and fingerprint can’t be entered.

ⒸCopyright 2007 Suprema Inc.

FCC Rules Caution Warning Information to User  Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment.  RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE  DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guaranteee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help

ⒸCopyright 2007 Suprema Inc.

Specifications Item Specification CPU 400MHz DSP Fingerprint sensor 500dpi Optical / Capacitive sensor User capacity 5000 users (10,000 templates) Log capacity 50,000 events Matching speed Less than 1 second Operation mode Fingerprint, RF Card, RF card + Fingerprint Network Interface TCP/IP, RS485 Internal relay Deadbolt, EM lock, door strike, automatic door TTL I/O 2 inputs for exit switch and door sensor Wiegand In/Out 1 Port (Wiegand Input or Wiegand Output is used according to the configuration.) Sound and Interface Multi-color LED and multi-tone buzzer Rated Voltage DC 12V (Min. 500mA and above) (When sharing the power with a device such as electric door lock, enough power is required considering the power requirement for the connected device.) Card option 125kHz EM card (EM4100) 125kHz HID Proximity Card 13.56MHz Mifare Card Size 50 x 160 x 37 mm (Width x Height x Depth) Certified KCC, CE, FCC

16F Parkview Office Tower, Jeongja-dong, Bundang-gu,

Seongnam, Gyeonggi, 463-863 Korea E-mail : [email protected] Website : www.supremainc.com Functions and specifications of the product are subject to changes without notice due to quality enhancement or function update. For any inquiry on the product, please contact Suprema Inc.