PDA Range PDA200/2 Installation Instructions Manual

Text of PDA Range PDA200/2 Installation Instructions Manual

PDA200/2, PDA500/2, PDA1000/2

INSTALLATION INSTRUCTIONS This equipment must be installed by a suitably skilled and technically competent person. Please read these instructions carefully before installation. Important notes .......................................................................................... 2 What is an audio frequency induction loop system? .............................. 3 Familiarisation with your PDA Pro-Range induction loop ampli

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 2

Important notes These instructions are general and cannot be considered to cover every aspect of audio-frequency induction loop system design and installation. We recommend you read BS7594 (The Code of Practice for Audio-Frequency Induction Loop Systems) and EN60118-4 (Magnetic field strength in audio frequency induction loop systems for hearing aid purposes), copies of which are

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 3

An audio-frequency induction loop system (AFILS) allows hearing impaired people to hear more clearly. Most hearing aids have a ‘T’ or ‘MT’ switch which allows them to pick up the electromagnetic field generated by an induction loop system. The hearing aid converts this signal into a sound suited to its user’s specific hearing requirements. Any hearing impaired person pos

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 4

INPUT MODE SELECT SWITCH Allows the MIC./LINE input to be configured for Mic or Line operation and for optional 11V phantom power to be switched to the inputs. SW1 1 2 3 4 Familiarisation with your Pro-Range induction loop amplifier MIC. INPUT Accepts standard three-pin male XLR type connectors. Optional 11V phantom power is available via input mode select switch 2. MIC./LINE INPU

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 5

COMPRESSION INDICATORS Give a visual indication of the amplifier’s compressor activity. Installers should refer to these indicators when using the amplifier’s input signal level controls. For best results, we recommend you set the inputs so that the LOW compression indicator is lit most of the time and the HIGH compressor indicator illuminates only with peaks in the input sign

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 6

Loop cable selection Almost any single core tri-rated cable can be used for the induction loop provided it is of the appropriate DC resistance (ideally 0.5 to 1 Ohm). The graph on the right shows the recommended CSA for different lengths of loop cable. Simply work out the length of the loop required and choose a cable size that falls into the non-shaded area of the graph. 50 100

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 7

In addition to the amplifier’s two XLR inputs (MIC. and MIC./LINE), up to 10 additional microphone or line level inputs (any mix) can be daisychained to the amplifier’s ‘OUTREACH’ connector via a range of specially designed wall, ceiling or desk mountable single gang plates. Several different Outreach plates are available covering the most common variants of audio connecto

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 8

Induction loop amplifier (1) Designed to be free-standing or, if required, wall or rack mounted using our optional PDA/WM or PDA/RM kits. Loop cable (4) Run the loop cable (see page 6 for recommended cable types) around the perimeter of the room at floor or ceiling height. Note that ceiling loops will not be practical in all applications, i.e. churches with high roofs. If install

PDA Range Amplifier Owners Instructions: