PDA Range PDA200/2 Installation Instructions Manual
Text of PDA Range PDA200/2 Installation Instructions Manual
PDA200/2, PDA500/2, PDA1000/2
INSTALLATION INSTRUCTIONS
This equipment must be installed by a suitably skilled and technically
competent person. Please read these instructions carefully before installation.
Important notes .......................................................................................... 2
What is an audio frequency induction loop system? .............................. 3
Familiarisation with your PDA Pro-Range induction loop ampli
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 2
Important notes
These instructions are general and cannot be considered to cover every aspect of
audio-frequency induction loop system design and installation.
We recommend you read BS7594 (The Code of Practice for Audio-Frequency Induction
Loop Systems) and EN60118-4 (Magnetic field strength in audio frequency induction loop
systems for hearing aid purposes), copies of which are
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 3
An audio-frequency induction loop system (AFILS) allows hearing impaired
people to hear more clearly.
Most hearing aids have a ‘T’ or ‘MT’ switch which allows them to pick up the
electromagnetic field generated by an induction loop system. The hearing aid
converts this signal into a sound suited to its user’s specific hearing requirements.
Any hearing impaired person pos
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 4
INPUT MODE SELECT SWITCH
Allows the MIC./LINE input to be configured for
Mic or Line operation and for optional 11V phantom
power to be switched to the inputs.
SW1
1
2
3
4
Familiarisation with your Pro-Range induction loop amplifier
MIC. INPUT
Accepts standard three-pin male XLR
type connectors. Optional 11V
phantom power is available via input
mode select switch 2.
MIC./LINE INPU
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 5
COMPRESSION INDICATORS
Give a visual indication of the amplifier’s compressor activity.
Installers should refer to these indicators when using the
amplifier’s input signal level controls.
For best results, we recommend you set the inputs so that
the LOW compression indicator is lit most of the time and
the HIGH compressor indicator illuminates only with peaks in
the input sign
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 6
Loop cable selection
Almost any single core tri-rated
cable can be used for the
induction loop provided it is of
the appropriate DC resistance
(ideally 0.5 to 1 Ohm).
The graph on the right shows the
recommended CSA for different
lengths of loop cable. Simply
work out the length of the loop
required and choose a cable size
that falls into the non-shaded
area of the graph.
50
100
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 7
In addition to the amplifier’s two XLR inputs (MIC. and MIC./LINE), up to 10 additional
microphone or line level inputs (any mix) can be daisychained to the amplifier’s ‘OUTREACH’
connector via a range of specially designed wall, ceiling or desk mountable single gang plates.
Several different Outreach plates are available covering the most common variants of audio
connecto
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 3 • Page 8
Induction loop amplifier (1)
Designed to be free-standing or, if required, wall or rack
mounted using our optional PDA/WM or PDA/RM kits.
Loop cable (4)
Run the loop cable (see page 6 for recommended
cable types) around the perimeter of the room at
floor or ceiling height. Note that ceiling loops will
not be practical in all applications, i.e. churches with
high roofs.
If install