Monogram ZV925 Installation Instructions Manual
Text of the manual
BEFORE YOU BEGIN
Read these instructions
completelg
and
carefullg.
, IMPORTANT-Save these instructions
for local
inspector's
use.
"IM
PORTANT- Observe all governing
codes and
ordinances.
,
Note to Installer
- Be sure to leave these instructions
with the Consumer.
,
Note to Consumer
- Keep these instructions
for
future reference.
, Skill Level - Installation of this vent hood requires
basic mechanical
and electrical skills.
, Completion
time - i to 3 hours.
,
Proper installation
is the responsibilitg
of the installer.
,
Product failure clue to improper
installation is not
covered under the Warrantg.
ACAUTION:
Due to the weight and size of these vent hoods and
to reduce the risk of personal injurg or damage
to the
product, THREE PEOPLEARE REQUIRED FOR PROPER
INSTALLATION.
APRUDENCE :
A cause du poids et des dimensions du ces hottes et
pour r6duire les risques de blessures ou de dommages
du produit, IL FAUT TROIS PERSONNESPOUR FAIRE
UNE INSTALLATION CORRECTE.
AWARNING:
To reduce the risk of fire or electrical shock, do not use
this range hood with ang external solid-state speed
control device. Ang such alteration
from original factorg
wiring could result in damage to the unit and/or create
an electrical safetg hazard.
VERTISSENENT
:
Pour r6duire le risque d'incendie ou de choc 61ectrique,
il ne faut pas utiliser cette hotte avec un r6gulateur
de vitesse 61ectronique externe. Toute modification
de
ce tgpe du branchement
d'usine peute endommager
I'appareil ou cr6er un risque de choc 61ectrique.
TO REDUCETHE RISK OF FIRE, USEONLY METAL
DUCTWORK.
AIAm^n_ll_lf" r ,a: ToREDUCE
THE
RISK
OFFIRE,
ELECTRICALSHOCKOR INJURY,OBSERVETHEFOLLOWING:
A. Usethis unit onlg inthe manner intended bg the
manufacturer. Ifgou have ang questions,contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at the
service panel and lock service panel to prevent power from
being switched on accidentallg. Ifthe service panel cannot
be locked, fasten a tag or prominent warning labelto the
panel.
AAVERTISSEMENT:
POURRI_DUIRELERISQUED'INCENDIE,DECHOC
I_LECTRIQUEOU DEBLESSURES,IL FAUTOBSERVERLES
REGLESSUIVANTES:
A. Utilisezcet appareil uniquement de la mani@e pr@ue par
le fabricant. Encas de question, consultez lefabricant,
B. Avant toute intervention ou nettoyage, coupez
I'alimentation &lectrique au disjoncteur et verrouiller
le panneau du disjoncteur pour @iter la misesous
tension accidentelle.S'iln'est pas possiblede verrouiller
le panneau du disjoncteur, attachez un placard ou une
@iquettetr@svisible au panneau.
• For general ventilating use onlg. Do not use to exhaust
hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical wiring
must be done bg qualified person(s)in accordance with
all applicable codes and standards, including fire-rated
construction.
• Sufficientair is needed for proper combustion and
exhausting of gasesthrough the flue (chimneg)of fuel
burning equipment to prevent back drafting. Followthe
heating equipment manufacturer's guidelines and safetg
standards such as those published bg the National Fire
Protection Association (NFPA),and the American Societg
for Heating, Refrigerationand Air Conditioning Engineers
(ASHRAE),and the local code authorities.When applicable,
install ang makeup (replacement) air sgstem in accordance
with local building code requirements. VisitGffAppliances.
cam for available makeup air solutions.
• Local codes varg. Installation of electrical connections
and grounding must complg with applicable codes. In
the absence of local codes, the vent should be installed
in accordance with National Electrical CodeANSI/NFPA
70-1990 or latest edition.
A,,-^,
l-rl,,_
!_i
_lsL%_U|IUI_i:
To reduce riskof fire and to properlg
exhaust air, be sure to duct air outside. Do not vent exhaust
air into spaceswithin walls or ceilings or into attics, crawl
spaces or garages.
APRUDENCE :, fautprendre
soind'installer
un conduit vers I'ext@ieurpour r@duire le risque d'incendie
et pouvoir @acuer I'air correctement. IIne faut pas @acuer
I'air dans I'espaceentre les parois d'un mur, un plafond ou un
grenier, un espacesanitaire ou un garage.
Advance Planning ..................................................................................
/4
Power Supplg ...........................................................................................
4
Duct Fittings ............................................................................................
5
Installation
Preparation
Installation Height .................................................................................
6
Tools and Materials Required...........................................................
7
Remove the Packaging .......................................................................
7
Parts Provided ..........................................................................................
8
Step 10, Install Upper Duct Cover...............................................
16
Step 11, Install Lower Duct Cover...............................................
17
Step 12, Install Duct Cover Trim ...................................................
17
Step 13, Install Metal Filter..............................................................
17
Step 14, Finalize Installation ...........................................................
17
Installation
Instructions--Recirculating
Step 1, Mount Template ...................................................................
18
Step
Step
Step
Step
Installation
Preparation
Step
Construct Ceiling Support ...........................................................
9-11
Step
Installation
Instructions--Vented
to the Outside
Step
Step 1, Mount Template ...................................................................
12
Step
Step 2, Adjust Frame Height...........................................................
12
Step
Step 3, Cut Duct to Length for Vented Installation ............13
Step
Step 4, Install the Support Frame................................................
13
Step
Step 5, Install Hood Attachment Screws .................................
13
Step
Step 6, Mount the Hood onto the Support .............................
1/4
Step
Step 7, Connect Cables.....................................................................
1/4
Step
Step 8, Connect Electrical ................................................................
15
Step
Step 9, Prepare the Duct Covers..................................................
16
2, Adjust Frame Height...........................................................
18
3, Install Air Deflector, Cut Duct
for Recirculating Operation ............................................
19
4, Install Upper Support Frame..........................................
19
5, Install Lower Structure to Upper Structure ............20
6, Install Blower/Motor ...........................................................
20
7, Install Hood Attachment Screws .................................
21
8, Mount the Hood onto the Support .............................
21
9, Connect Cables.....................................................................
21
10, Connect Electrical .............................................................
22
11, Prepare the Duct Covers...............................................
23
12, Install Upper Duct Cover...............................................
23
!3, Install Lower Duct Cover...............................................
24
14, Install Duct Cover Trim ...................................................
24
15, Install Filters.........................................................................
25
16, Finalize Installation ...........................................................
25
PRODUCT DIMENSIONS
*Height
to
ceiling
T_
_
.......
£ 2 3/4"
27 9/16"
_ ................35 7/8"' ................ i
* The supplied
duct cover fits 7'-11" to 9' ceiling
heights. For 9'-1" to 10'-1" ceilings, order ZX92510.
These vent hoods
are supplied
with a support
frame
for ceiling
heights of 7'-11" to 10'-1".
Decorative
duct covers conceal
the ductwork
running
from the top of the hood to the ceiling.
ZX92510
accessorg
is available
for ceiling
heights
of
9'-1" to 10L1 ''.
24" min.*
30" max.*
/
* Exact installation
height depends
on ceiling height.
NOTE: Installation
height
should
be measured
from
the cooking
surface
to the bottom
of the outer
glass
portion
of the hood.
This hood must be installed
24" min. and 30" max.
above the cooking surface. The cooking surface
should
be at least 36" above the floor.
This hood mag be vented to the outdoors,
or it can be
installed for recirculating
operation.
This hood can be installed
over ang Monogram
electric
or gas cooktop.
It cannot
be installed
over a
Monogram
Professional
cooktop
or range.
vent hoods are equipped
for 8" round
ductwork.
, Determine
the exact
location
of the vent hood.
, Plan the route for venting
exhaust
to the outdoors.
, Use the shortest
and straightest
duct route
possible. For satisfactorg
performance,
duct run
should
not exceed
100 ft. equivalent
length for ang
duct configurations.
, Refer to "Duct Fittings" chart to compute
the
maximum
permissible
length for duct runs to the
outdoors.
, Use rigid metal ductwork
onlg.
, Install o roof cap with damper
at the exterior
opening.
Order the cap and ang transitions
needed
in advance.
,When applicable, install ang makeup (replacement)
air sgstem in accordance with local building code
requirements. Visit GEAppliances.com for available
makeup air solutions.
Ceiling
Framing
for Adequate
Support
,These
vent hoods are heavg. Adequate
structural
support
must be provided. The ceiling structure
must be capable
of supporting
the weight
of the
hood and ang inadvertent
user contact
loads
(approximatelg
200 pounds). The hood support
frame will be supported
bg 2 x 4 cross framing.
, Installation
will be easier if the vent hood is
installed
before the cooktop
or countertop
below is
installed.
Accessorg
Duct Cover
.All models are shipped with a duct cover for ceiling
heights of 7'-11" to 9'.
ZX92510
accessory
36-3/4"
duct cover is
available
to reach 9'-1" to 10'-1" ceiling
heights.
The accessory
should
be ordered
with the hood
and be on site before final framing
and wall
finishing.
POWER SUPPLY
IMPORTANT -(Please
read carefully)
AWARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE lUST
BE
PROPERLYGROUNDED.
AATTENTION
: POUR
DES
RAISONS
DE
SECURITE,CET APPAREIL DOlT ETRECORRECTEMENT
HIS A LATERRE.
Remove house fuse or open circuit
breaker
before
beginning
installation.
Do not use an extension
cord or adapter
plug with
this appliance.
Follow National
electrical
codes or
prevailing
local codes and ordinances.
Electrical
Supplg
This vent hood must be supplied
with
120V, 60Hz,
and connected
to an individual,
properly
grounded
branch
circuit, and protected
by a 15 or 20 amp
circuit
breaker
or time delay fuse.
, Wiring
must be 2 wire with ground.
, If the electrical
supply does not meet the above
requirements,
call a licensed electrician
before
proceeding.
, Route house wiring
in the ceiling, as close to the
installation
location
as possible. Allow additional
length from ceiling joists to reach the junction
box on the bottom
of the hood support
frame.
, Connect
the wiring
to the house wiring
in
accordance
with local codes.
Grounding
Instructions
The grounding
conductor
must
be connected
to
a ground
metal, permanent
wiring
system,
or an
equipment-grounding
terminal
or lead on the hood.
I
The mproper
connection
of
equipment-grounding
conductor
can result in a risk
of electric
shock. Check with a qualified
electrician
or service
representative
if gou ore in doubt
whether
the appliance
is properly
grounded.
AAVERTISSEMENT :
Le mauvais
branchement
du fil de mise 6 la terre
peut causer
un choc 61ectrique.
En cas de doute,
consultez
un 61ectricien qualifi6
ou un technicien
pour d6terminer
si I'appareil
est 6 la terre.
Use this chart to compute
maximum
permissible
lengths for
duct runs to outdoors.
NOTE: Do not exceed maximum
permissible
equivalent
lengths!
Maximum
duct
length:
lO0 foot for range
hoods.
Flexible ducting:
If flexible
metal ducting
is used,
all the equivalent
feet values in
the table should
be doubled.
The flexible
metal duct should
be straight
and smooth
and
extended
as much as possible.
DO NOT use flexible
plastic
ducting.
NOTE: Ang home ventilation
sgstem, such as a ventilation
hood, mag interrupt
the proper
flow of combustion
air and
exhaust
required bg fireplaces, gas
furnaces, gas water heaters and
other naturallg
vented sqstems.
To minimize
the chance of
interruption
of such naturalkd
vented sgstems, follow the
heating
equipment
manufacturer's
guidelines
and safetg standards
such as those published
bg NFPA
and ASHRAE. When applicable,
install ang makeup
(replacement)
air s.gstem in accordance
with local
building
code requirements.
Visit
GEAppliances.com
for available
makeup
air solutions.
Equivalent
Duct Piece
Dimensions
Length*
Round,
1 ft.
straight
(per foot
length)
Total
guantitg
Equivalent
Used
Length
3-1/4" x 12"
1 ft.
straight
(per foot
length)
90° elbow
!7ft.
!0 ft.
45° elbow
3-1/4" x 12"
90° elbow
43 ft.
3-i/4"
x 12"
45° elbow
26 ft.
3-i/4"
x 12"
90° flat elbow
102 ft.
_,_,_
8" round to
3-!/4"
x !2" transition
2 ft.
3-i/4"
x 12" to 8"
round transition
5 ft.
8" round
to 3-1/4" x 12"
transition 90° elbow
6 ft.
3-1/4" x 12" to 8" round
round transition 90° elbow
13 ft.
Round
wall cap
with damper
32 ft.
3-1/4,,×12,,wallcap
with damper
75 ft.
Round
roof cap
44 ft.
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted bLIGE Evaluation
Engineering and reflect requirements for good
venting performance with ang ventilation hood.
Total Duct
Run