Monogram ZV925 Installation Instructions Manual

Text of the manual

BEFORE YOU BEGIN

Read these instructions completelg and carefullg. , IMPORTANT-Save these instructions for local inspector's use. "IM PORTANT- Observe all governing codes and ordinances. , Note to Installer - Be sure to leave these instructions with the Consumer. , Note to Consumer - Keep these instructions for future reference. , Skill Level - Installation of this vent hood requires basic mechanical and electrical skills. , Completion time - i to 3 hours. , Proper installation is the responsibilitg of the installer. , Product failure clue to improper installation is not covered under the Warrantg. ACAUTION: Due to the weight and size of these vent hoods and to reduce the risk of personal injurg or damage to the product, THREE PEOPLEARE REQUIRED FOR PROPER INSTALLATION. APRUDENCE : A cause du poids et des dimensions du ces hottes et pour r6duire les risques de blessures ou de dommages du produit, IL FAUT TROIS PERSONNESPOUR FAIRE UNE INSTALLATION CORRECTE. AWARNING: To reduce the risk of fire or electrical shock, do not use this range hood with ang external solid-state speed control device. Ang such alteration from original factorg wiring could result in damage to the unit and/or create an electrical safetg hazard. VERTISSENENT : Pour r6duire le risque d'incendie ou de choc 61ectrique, il ne faut pas utiliser cette hotte avec un r6gulateur de vitesse 61ectronique externe. Toute modification de ce tgpe du branchement d'usine peute endommager I'appareil ou cr6er un risque de choc 61ectrique. TO REDUCETHE RISK OF FIRE, USEONLY METAL DUCTWORK. AIAm^n_ll_lf" r ,a: ToREDUCE THE RISK OFFIRE, ELECTRICALSHOCKOR INJURY,OBSERVETHEFOLLOWING: A. Usethis unit onlg inthe manner intended bg the manufacturer. Ifgou have ang questions,contact the manufacturer. B. Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentallg. Ifthe service panel cannot be locked, fasten a tag or prominent warning labelto the panel. AAVERTISSEMENT: POURRI_DUIRELERISQUED'INCENDIE,DECHOC I_LECTRIQUEOU DEBLESSURES,IL FAUTOBSERVERLES REGLESSUIVANTES: A. Utilisezcet appareil uniquement de la mani@e pr@ue par le fabricant. Encas de question, consultez lefabricant, B. Avant toute intervention ou nettoyage, coupez I'alimentation &lectrique au disjoncteur et verrouiller le panneau du disjoncteur pour @iter la misesous tension accidentelle.S'iln'est pas possiblede verrouiller le panneau du disjoncteur, attachez un placard ou une @iquettetr@svisible au panneau. • For general ventilating use onlg. Do not use to exhaust hazardous or explosive materials or vapors. • Structural framing, installation work and electrical wiring must be done bg qualified person(s)in accordance with all applicable codes and standards, including fire-rated construction. • Sufficientair is needed for proper combustion and exhausting of gasesthrough the flue (chimneg)of fuel burning equipment to prevent back drafting. Followthe heating equipment manufacturer's guidelines and safetg standards such as those published bg the National Fire Protection Association (NFPA),and the American Societg for Heating, Refrigerationand Air Conditioning Engineers (ASHRAE),and the local code authorities.When applicable, install ang makeup (replacement) air sgstem in accordance with local building code requirements. VisitGffAppliances. cam for available makeup air solutions. • Local codes varg. Installation of electrical connections and grounding must complg with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical CodeANSI/NFPA 70-1990 or latest edition. A,,-^, l-rl,,_ !_i _lsL%_U|IUI_i: To reduce riskof fire and to properlg exhaust air, be sure to duct air outside. Do not vent exhaust air into spaceswithin walls or ceilings or into attics, crawl spaces or garages. APRUDENCE :, fautprendre soind'installer un conduit vers I'ext@ieurpour r@duire le risque d'incendie et pouvoir @acuer I'air correctement. IIne faut pas @acuer I'air dans I'espaceentre les parois d'un mur, un plafond ou un grenier, un espacesanitaire ou un garage.

Advance Planning ..................................................................................

/4 Power Supplg ........................................................................................... 4 Duct Fittings ............................................................................................ 5 Installation Preparation Installation Height ................................................................................. 6 Tools and Materials Required........................................................... 7 Remove the Packaging ....................................................................... 7 Parts Provided .......................................................................................... 8 Step 10, Install Upper Duct Cover............................................... 16 Step 11, Install Lower Duct Cover............................................... 17 Step 12, Install Duct Cover Trim ................................................... 17 Step 13, Install Metal Filter.............................................................. 17 Step 14, Finalize Installation ........................................................... 17 Installation Instructions--Recirculating Step 1, Mount Template ................................................................... 18 Step Step Step Step Installation Preparation Step Construct Ceiling Support ........................................................... 9-11 Step Installation Instructions--Vented to the Outside Step Step 1, Mount Template ................................................................... 12 Step Step 2, Adjust Frame Height........................................................... 12 Step Step 3, Cut Duct to Length for Vented Installation ............13 Step Step 4, Install the Support Frame................................................ 13 Step Step 5, Install Hood Attachment Screws ................................. 13 Step Step 6, Mount the Hood onto the Support ............................. 1/4 Step Step 7, Connect Cables..................................................................... 1/4 Step Step 8, Connect Electrical ................................................................ 15 Step Step 9, Prepare the Duct Covers.................................................. 16 2, Adjust Frame Height........................................................... 18 3, Install Air Deflector, Cut Duct for Recirculating Operation ............................................ 19 4, Install Upper Support Frame.......................................... 19 5, Install Lower Structure to Upper Structure ............20 6, Install Blower/Motor ........................................................... 20 7, Install Hood Attachment Screws ................................. 21 8, Mount the Hood onto the Support ............................. 21 9, Connect Cables..................................................................... 21 10, Connect Electrical ............................................................. 22 11, Prepare the Duct Covers............................................... 23 12, Install Upper Duct Cover............................................... 23 !3, Install Lower Duct Cover............................................... 24 14, Install Duct Cover Trim ................................................... 24 15, Install Filters......................................................................... 25 16, Finalize Installation ........................................................... 25 PRODUCT DIMENSIONS *Height to ceiling T_ _ ....... £ 2 3/4" 27 9/16" _ ................35 7/8"' ................ i * The supplied duct cover fits 7'-11" to 9' ceiling heights. For 9'-1" to 10'-1" ceilings, order ZX92510. These vent hoods are supplied with a support frame for ceiling heights of 7'-11" to 10'-1". Decorative duct covers conceal the ductwork running from the top of the hood to the ceiling. ZX92510 accessorg is available for ceiling heights of 9'-1" to 10L1 ''. 24" min.* 30" max.* / * Exact installation height depends on ceiling height. NOTE: Installation height should be measured from the cooking surface to the bottom of the outer glass portion of the hood. This hood must be installed 24" min. and 30" max. above the cooking surface. The cooking surface should be at least 36" above the floor. This hood mag be vented to the outdoors, or it can be installed for recirculating operation. This hood can be installed over ang Monogram electric or gas cooktop. It cannot be installed over a Monogram Professional cooktop or range.

vent hoods are equipped

for 8" round ductwork. , Determine the exact location of the vent hood. , Plan the route for venting exhaust to the outdoors. , Use the shortest and straightest duct route possible. For satisfactorg performance, duct run should not exceed 100 ft. equivalent length for ang duct configurations. , Refer to "Duct Fittings" chart to compute the maximum permissible length for duct runs to the outdoors. , Use rigid metal ductwork onlg. , Install o roof cap with damper at the exterior opening. Order the cap and ang transitions needed in advance. ,When applicable, install ang makeup (replacement) air sgstem in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. Ceiling Framing for Adequate Support ,These vent hoods are heavg. Adequate structural support must be provided. The ceiling structure must be capable of supporting the weight of the hood and ang inadvertent user contact loads (approximatelg 200 pounds). The hood support frame will be supported bg 2 x 4 cross framing. , Installation will be easier if the vent hood is installed before the cooktop or countertop below is installed. Accessorg Duct Cover .All models are shipped with a duct cover for ceiling heights of 7'-11" to 9'. ZX92510 accessory 36-3/4" duct cover is available to reach 9'-1" to 10'-1" ceiling heights. The accessory should be ordered with the hood and be on site before final framing and wall finishing. POWER SUPPLY IMPORTANT -(Please read carefully) AWARNING: FOR PERSONAL SAFETY,THIS APPLIANCE lUST BE PROPERLYGROUNDED. AATTENTION : POUR DES RAISONS DE SECURITE,CET APPAREIL DOlT ETRECORRECTEMENT HIS A LATERRE. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances. Electrical Supplg This vent hood must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. , Wiring must be 2 wire with ground. , If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. , Route house wiring in the ceiling, as close to the installation location as possible. Allow additional length from ceiling joists to reach the junction box on the bottom of the hood support frame. , Connect the wiring to the house wiring in accordance with local codes. Grounding Instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood. I The mproper connection of equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if gou ore in doubt whether the appliance is properly grounded. AAVERTISSEMENT : Le mauvais branchement du fil de mise 6 la terre peut causer un choc 61ectrique. En cas de doute, consultez un 61ectricien qualifi6 ou un technicien pour d6terminer si I'appareil est 6 la terre.

Use this chart to compute

maximum permissible lengths for duct runs to outdoors. NOTE: Do not exceed maximum permissible equivalent lengths! Maximum duct length: lO0 foot for range hoods. Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible. DO NOT use flexible plastic ducting. NOTE: Ang home ventilation sgstem, such as a ventilation hood, mag interrupt the proper flow of combustion air and exhaust required bg fireplaces, gas furnaces, gas water heaters and other naturallg vented sqstems. To minimize the chance of interruption of such naturalkd vented sgstems, follow the heating equipment manufacturer's guidelines and safetg standards such as those published bg NFPA and ASHRAE. When applicable, install ang makeup (replacement) air s.gstem in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. Equivalent Duct Piece Dimensions Length* Round, 1 ft. straight (per foot length) Total guantitg Equivalent Used Length 3-1/4" x 12" 1 ft. straight (per foot length) 90° elbow !7ft. !0 ft. 45° elbow 3-1/4" x 12" 90° elbow 43 ft. 3-i/4" x 12" 45° elbow 26 ft. 3-i/4" x 12" 90° flat elbow 102 ft. _,_,_ 8" round to 3-!/4" x !2" transition 2 ft. 3-i/4" x 12" to 8" round transition 5 ft. 8" round to 3-1/4" x 12" transition 90° elbow 6 ft. 3-1/4" x 12" to 8" round round transition 90° elbow 13 ft. Round wall cap with damper 32 ft. 3-1/4,,×12,,wallcap with damper 75 ft. Round roof cap 44 ft. *Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted bLIGE Evaluation Engineering and reflect requirements for good venting performance with ang ventilation hood. Total Duct Run