Risco GARDTEC 872 User Instructions
Text of the manual
User Information .........................................................
2
Using LCD Keypads
Introduction ...................................................................
3
User Code Types..........................................................
3
Duress Codes ...............................................................
4
Setting The System ......................................................
5
Setting & Unsetting via a Keyswitch .............................
5
Unsetting The System ..................................................
6
Part Setting The System...............................................
6 - 7
Area Setting ..................................................................
8
Removing Zones...........................................................
9
Testing The System......................................................
10
Viewing The Event Log.................................................
11 - 12
Changing The Chime Status.........................................
12 - 13
Programming User Codes ............................................
14 - 16
Programming Time & Date ...........................................
17
User Initiating Remote Access .....................................
18
Resetting After An Alarm ..............................................
19 - 20
Using LED Keypads....................................................
21
Setting The System ......................................................
21
Unsetting The System ..................................................
21
Part Setting The System...............................................
22
Area Setting ..................................................................
23
Removing Zones...........................................................
23 - 24
Testing The System......................................................
24
Viewing The Event Log.................................................
25
Changing The Chime Status.........................................
26
Programming User Codes ............................................
26
User Initiating Remote Access......................................
27
Resetting After An Alarm ..............................................
28
LED Display Glossary...................................................
29 - 30
System Attributes..........................................................
31 - 34
Service Record .............................................................
34
User Chart ....................................................................
35 - 36
ACE Instructions ...........................................................
37
Programming ACE Keyfobs onto your System.............
38
Page 1
GARDTEC 872
User Manual
GARDTEC 800 Series
User Manual
User Information
Customer Name:-
Customer Address:-
Control Panel Model
No of Keypads
Keypad 1 Location
Type
Keypad 2 Location
Type
Keypad 4 Location
Type
Keypad 5 Location
Type
Keypad 6 Location
Type
Keypad 7 Location
Type
Keypad 8 Location
Type
ACE Mode (if fitted)
Normal Security
High Security
Keyswitch 1 Location
Reserved User Code User No.
Keyswitch 2 Location
Reserved User Code User No.
Keyswitch 3 Location
Reserved User Code User No.
Keyswitch 4 Location
Reserved User Code User No.
Keyswitch 5 Location
Reserved User Code User No.
Keyswitch 6 Location
Reserved User Code User No.
Keyswitch 7 Location
Reserved User Code User No.
Keyswitch 8 Location
Reserved User Code User No.
Installation Company Name:-
Installation Company Address:-
Installation Company Tel.
Fax.
Other Information:-
Note: Please ensure this section is completed by the installation engineer
GARDTEC 800 Series
User Manual
Introduction
The Gardtec 872 control panel is a multi zone microprocessor controlled unit. Two
types of display are available for the system keypads, a) LCD offering a 32 character
display with zone descriptors and user names or, b) Twin seven segment LED displays
offering limited control/user programming options. The LED type displays normally
used for setting and unsetting at secondary points.
Please take time to familiarise yourself with the type of equipment fitted to your
premises as it will prove invaluable whilst using this manual.
User Code Types
99 user codes are available offering 19 code types with varying levels of access to the
system. User number 1 will always be a Master Level User but the remaining User
Codes may be programmed (by a Master Code) to the required level of access. These
may be changed at any time via a Master level code
The User Code levels available and the functions available for the levels are:-
Master
Allows Setting, Unsetting, Zone Remove (if programmed by
engineer), Test System, View Log, Chime On/Off, User
Codes, Set Time/Date, Reset After Alarm (if programmed
by engineer), Unsetting.
Cleaner
Full System Setting (from unset system),
Cleaner Area Unsetting (from set system),
Cleaner Part Set (from part cleaner set system).
Area 1 to 7 User
Allows Area 1 to 7 Setting, Area 1 to 7 Part Setting,
Area 1 to 7 Unsetting.
Main User
Allows Setting, Part Setting, Zone Remove (if programmed
& Main User 1 to 7
by engineer), System Test, Unsetting, Reset after Alarm (if
programmed by engineer). Main User 1 to 7 are specific to
their area.
Control
Used for control of other equipment (see installation
company for details).
Set Only
Only Allows for the setting of the system.
Note:
For information on using Duress on the Gardtec 872 see Using
Duress Section.
Duress Codes may be programmed onto your GardTec 872 system. When used a
Duress code will appear to operate the security system in the normal way but will also
send a PA (personal attack) signal to central station (if programmed).
One of two types of Duress codes may be programmed onto your system.
a)
Add 1 to the first digit of any User Code e.g the normal User Code is 5678 so
the Duress code for this User would be 6678.
If programmed to this type of Duress by the engineer the 1 digit
increment will apply to all User Codes on the system.
b)
User 7 Duress. Any code that is programmed as User number 7 will be the
Duress code for that system.
Your installation company will advise you on the type of Duress codes that are
programmed on your system and the correct use of those codes.
Setting The System
1)
With the display showing:-
2)
Enter the User code (followed by YES if
Master or Main type code has been used).
The display will show for example:-
and a continuous exit tone will sound
3)
Exit the premises via the authorised exit
route (the exit tone will change if any detectors
are violated during exit)
4)
Once the premises are secure listen that the exit
tone returns to the continuous tone.
5)
Wait until the exit tone finishes before leaving.
Note:
Setting the system with an area code will set only the area
associated with that code.
Note:
Setting an unset system with a cleaner code will set the full system.
Setting & Unsetting the
System via a Keyswitch
One of two types of keyswitch(es) may have been fitted to your system.
Normal
To set the system with a normal keyswitch, insert the key and turn to the ON position
then remove the key. To unset insert the key and turn to the OFF position.
Biased
To set the system with a biased keyswitch, insert the key and turn it then return the key
to the original position and remove. To unset repeat this operation.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
EXIT Now ! 1 2 3 C
All Zones ON 15
Unsetting The System
1)
Enter the premises via the authorised entry route
(the broken entry tone will sound),
proceed to the keypad.
2)
At the keypad enter a valid code, the display
will show:-
3)
The system is now unset.
Note:
If an Area Code has been entered only the area associated
with that code will be unset.
Note:
If a Cleaner Code has been entered only the cleaner area will be unset.
Note:
For DD243 systems ACE keyfobs may have to be used to unset the
system, chexk with your installation company.
Note:
In the event of the system being set using ACE when the battery is low
the display will show ACE Battery Low when the system is unset press
Yes to clear the display and change the battery in the keyfob.
Part Setting The System
(using Master & Main type codes)
1)
With the display showing:-
2)
Enter a Master or Main type code, the
display will show for example:-
3)
Press 1, 2 or 3 (for Part 1, 2 or 3), the
display will show for example:-
Note:
If a Global code (Master or Main) has been used all areas that
are being set will be Part 1 set. Note: If an Area Main code has
been used only Part 1 set for that associated area will occur.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set , STUART ?
EXIT Now! 1 2 3 C
Part 1
15
The exit tone may or may not be heard
dependant on the system settings.
5)
Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop or a single
beep will be emitted (dependant on system
settings).
Part Setting System
(using Area 1 to 7 codes)
1)
With the display showing:-
2)
Enter an Area Code (1to 7), the exit
tone will sound and the display
will show for example:-
3)
Press NO then 1, 2 3 (for the Part Set
you require), the display will show for example:-
4)
The exit sounders may or may not go silent
this will depend on the system settings.
5)
Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop or a single
beep will be emitted (dependant on system
settings).
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
EXIT Now ! 1
All Zones ON 15
EXIT Now ! 1
Part 1
20
(using Master or global Main codes)
Areas will need to have been set up by the installation company.
1)
With the display showing:-
2)
Enter a Master or global Main code, the
display will show for example:-
3)
Press YES to start setting the system,
the exit tone will sound and the display
will show:-
4)
To turn Area 1 Off press YES, 1
and / or
To turn Area 2 Off press YES, 2
and / or
To turn Area 3 Off press YES, 3
and / or
To turn Area 4 Off press YES, 3
and / or
To turn Area 5 Off press YES, 3
and / or
To turn Area 6 Off press YES, 3
and / or
To turn Area 7 Off press YES, 3
and / or
To turn the Cleaner Area Off press YES, 0
As areas are turned off they will be removed
from the display.
5)
Exit the premises or retire to an un-protected
area (as detectors are violated the continuous
exit tone will change).
Note:
Areas must first be programmed by the installation company before
they will appear on the display.
Area Setting (using Area codes)
Area codes are only effective to their own area with the exception of the cleaner area.
This may be turned off by an area code (only if all areas are in the unset condition).
Use is the same as Setting the system shown on page 5 but only the relevant area will
be set
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set. ELIZABETH ?
EXIT Now ! 1 2 3 C
All Zones ON 30
Removing Individual Zones
(Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code. It should be noted that if an Area
Main code is being used, only zones associated with that area may be removed.
1)
With the display showing:-
2)
Enter a Master or Main level code,
the display will show:-
3)
Press NO, the display will show:-
4)
Press YES, the display will show:-
5)
Enter the zone number you wish to
remove followed by YES (pressing
NO will 'un-remove' a zone), the
display will show:-
6)
Repeat step 5 until you have removed all
the required zones.
7)
Press 0 to escape, the display will show:-
8)
Press YES, the continuous exit tone will
sound.
9)
Exit the premises via the authorised
exit route ( the exit tone will change as detectors
are violated). When the premises are secure
listen that the exit tone returns to the continuous
tone. Wait until the exit tone finishes before leaving.
Note:
Zone remove is only effective for the one set.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Set . STUART ?
Do you want to . .
REMOVE Zones ?
Enter Zone No. - -
then + YES or - NO
Enter Zone No. - -
then + YES or - NO
Testing The System
(Master & Main codes only)
1)
With the display showing:-
2)
Enter a Master or Main level code,
the display will show:-
3)
Press NO, the display will show:-
4)
Press NO, the display will show:-
5)
Press YES, the display will show:-
6)
Press YES to test the full system
or
NO until the area you wish to test is shown
7)
Press YES, the display will show:-
for 3 seconds
Then for example:-
8)
Pressing 1 will enter zone Status mode (All zones will show on the display
and will be deleted as each zone is triggered). Press 0 to escape.
Pressing 6 will silence the internal sounder,
Pressing 4 will toggle the Strobe On/Off,
Pressing 9 will toggle the Bell On/Off
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
REMOVE Zones ?
Do you want to . .
TEST the System ?
Test ALL Areas ?
1=Status 4 = Strobe
6 = Sounder 9 = Bell
< All Zones OK >
TESTING . . .
Whilst in Test mode any zones violated
will sound the internal sounder (if it has
not been silenced) and show on the
display.
10)
When you have finished testing the
system press 0 twice, the display will show:-
Viewing The Event Log
(Master code only)
1)
With the display showing:-
2)
Enter a Master Code, the display
will show for example:-
3)
Press NO three times, the display
will show:-
4)
Press YES, the display will show:-
for 3 seconds
Then, for example:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
View the LOG ?
While Viewing . . .
1 = Printer On / Off
Read Log
01 JAN 18 : 58 : 01
This is the most recent event in the log.
Whilst viewing the Log,
Pressing NO will move back to the previous event.
Pressing YES will move forward to the next event.
Pressing 7 will take you to back to the last event of
the previous day.
Pressing 9 will take you forward to the first event of
the next day.
6)
When you have finished viewing the Log press 0
twice the display will show:-
Changing The Chime Status
(Master code only)
The Chime zones will have previously been programmed by the installation company.
A Master level code may change the status of the Chime between On and Off. To do
so proceed as follows:-
1)
With the display showing:-
2)
Enter a Master Code, the display will
show for example:-
3)
Press NO four times, the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Change Chime ?
Press YES the display will show for example:-
Or:-
5)
Press NO to change the status of the Chime,
then press YES, the display will show:-
6)
Press 0 to escape, the display will show:-
Chime is Off ok ?
Chime is On ok ?
Do you want to . .
Change Chime ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Programming User Codes
(Master code only)
The charts on pages 2 & 35 should be completed by the engineer/user for future
reference of what codes have been allocated on your system. Under no
circumstances should the actual user code be written down.
If your installation company has given you keyswitches for the operation of your
system the last five user codes may have been reserved for use by these keyswitches.
If your engineer has indicated (see pages 2 & 35) that some
of the user numbers on your system have been reserved
you should not use them whilst programming user codes. If
you do so your system may be adversely affected
1)
With the display showing:-
2)
Enter a Master Code, the display will show:-
3)
Press NO five times, the display will show:-
4)
Press YES, the display will show:-
5)
Enter the user number (1 to 99 ) that you
wish to program followed by YES, the
display will show:-
At this point the display may ask if this code is
for ACE (Keyfob) dependant on the system
settings. Press Yes or No as required if this
question is asked.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Prog. USER CODES ?
Enter User No. - -
(1- 99) Then YES
Now Enter Code . .
- - - - - - Then YES
Enter the code you require (codes may be 4,
5 or 6 digits) followed by YES.
(Entering 000000 will delete an existing code)
Note:
If the code already exists or is a duress of
another code an error will be shown,
choose another code and return to step 6
7)
The display will show:-
(not if user 1 is being programmed).
8)
Press No until the level of code you require is
displayed then press Yes. The display will
show for example:-
9)
If you wish to accept the name shown press
YES and jump to step 13
Or
If you wish to change the name shown press
NO, the display will show:-
10)
You may now enter up to nine characters for
the user name using the layout shown below
for the allocation of characters.
User 02 Name
= USER 02
User 1 Name
>
1
2
3
4
5
6
7
8
9
0
YES
NO
ABC
DEF
GHI
JKL
MNO
PQR
STU
VWX
YZ
0-9
Code Type
= Master ok ?
Referring to the character map enter the required
character (pressing the 3 key will display 'G', pressing
it again will show 'H' and again will show 'I '), once
the correct character is displayed press YES and the
display will move on to the next position.
12)
Continue entering characters (up to 9). If
you require a blank space press YES while
the '-' is displayed to show the space this will not
be displayed after programming is completed.
13)
As you press YES for the ninth character
(or if you have jumped from step 9) the
display will change to:-
14)
If you wish to program other User Codes
return to step 4
Or
Press 0 to return to:-
Do you want to . .
Prog. USER CODES ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Programming Time & Date
1)
With the display showing:-
2)
Enter a Master Code, the display will show:-
3)
Press NO six times, the display will show:-
4)
Press YES the display will show:-
5)
For UK use press Yes. The display will show:-
6)
Press No. The display will show:-
7)
Enter the last two digits of the year e.g 03 if the
year is 2003 then Yes. The display will show:-
8)
Press Yes. Display will show:-
9)
Enter the Day and Month e.g 11 / 09 for the
11th September then press Yes. The display
will show:-
10)
Enter the current Time using the 24Hr format
e.g 20:30 for 8:30pm then press Yes. The
display will show:-
11)
Press 0 the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Set DATE / TIME ?
Summer - Adjust is
On ok ?
Year is 2000
ok ?
Enter Year
20-- Then YES
Year is 2003
ok ?
Enter Day / Month
- - / - - Then YES
Enter Hours : Mins
- - / - - Then YES
Do you want to . . .
Set Time / Date
User Initiating Remote Access (Optional)
Access Remote allows your installation company to examine your system and re-
program system settings as you need the changes without the need for an engineer to
visit your premises.
If your system has remote communications fitted your installation company may have
programmed the system so that you initialise the Access Remote call (usually on lines
with incoming calls barred).
To initiate the Remote Call follow the instructions below.
1)
Negotiate with your installation company when you should
initiate the Remote Call.
2)
With the display showing:-
3)
Enter a Master Code, the display will show
for example:-
4)
Press NO seven times, the display will show:-
5)
Press YES the display will show:-
Until Dialling commences
Then:-
Until Connection
Then:-
6)
When your installation company has finished
the display will show:-
Note:
In the event of any errors the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Access Remote ?
Please WAIT
Please WAIT
Dialling
Please WAIT
Connect
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
! ! ! ! ERROR ! ! ! !
Try Again . . . .
Resetting After an Alarm
Your installation company will have programmed the reset modes for your system so
that it complies to your insurance company and legislation requirements.
Your installation company will have informed you as to the type of reset that your
system is set for.
Before attempting to reset your system ensure that the system is Un-set.
1)
If the system is programmed for any code reset
enter a user (followed by YES if Master or Main
code is used), the exit tone will sound and the
display will show for example:-
2)
Enter the code again to abort the setting
3)
The system is now reset
Or
If a higher level of code is required one of
the following displays will be shown:-
Use a Master code to reset the system.
Or:-
Call the installation company
Or:-
Call the installation company and quote
the number given
Or:-
Call the installation company and quote
the number given
Or:-
Can't Set Use
Master Code
Can't Set Use
ENGNR Code
Can't Set Use
ENG +Anti Code 1234
Can't Set Use
Anti Code 1234
EXIT Now ! 1 2 3 C
All Zones ON 15
To reset the system with an anti-Code, contact
the central station or engineer (as instructed by
the installation company) and quote the source
given by the display.
5)
The central station or engineer will give a return
Anti-Code ( this may contain the YES & NO keys)
for example 5, YES, 2, 4.
6)
Enter this Anti-Code into the keypad
7)
The system is now reset.
Using LED Keypads
This section is dedicated to using LED keypads (Twin Seven Segment).
Setting The System
1)
With the display showing T M
2)
Enter the User Code (followed by YES if Master or Main type code has been
used).
3)
The display will show D $ and the exit tone will sound. Exit the premises via
the authorised exit route (the exit tone will change if any detectors are
violated during exit).
4)
Once the premises are secure listen that the exit tone returns to the
continuous tone.
5)
Wait until the exit tone finishes before leaving.
Note:
Setting the system with an area code will set only the area associated
with that code.
Note:
Setting an unset system with a cleaner code will set the full system.
Unsetting The System
1)
Enter the premises via the authorised entry route (the broken entry tone will
sound).
2)
Proceed to the keypad, enter a valid user code, the display will show T M.
3)
The system is now Unset.
Note:
If an area code has been entered only the area associated with that code
will be Unset.
Note:
If a cleaner code has been entered only the cleaner area will be Unset.
Note:
In the event of the system being set using ACE when the battery is low
the display will show A B when the system is unset press Yes to clear
the display and change the battery in the keyfob.
Part Setting The System
(using Master & Main type codes)
1)
With the display showing T M Enter a Master or Main type code
2)
The display will show R D (flashing). Press 1, 2 or 3 (for Part 1, 2 or 3) the
display will show the D and:-
The two bottom bars if Part 1 has been selected (D %)
The top and bottom bars if Part 2 has been selected (D &)
The bottom bar only if Part 3 has been selected (D ])
Note:
If a Global code (Master or Main) has been used all areas that are being
set would be Part Set.
Note:
If an Area Main code has been used only the Part Set associated with
that area would be Part Set.
3)
The exit tone may or may not be heard dependant on the system settings.
4)
Exit the premises or retire to an unprotected part of the system. At the end
of the exit time either the exit tone will stop or a single beep will be emitted
(dependant on system settings).
Part Setting System (using Area 1, 2 or 3 codes)
1)
With the display showing ' Un ' Enter an Area code (1, 2,3, 4, 5, 6, 7).
2)
The exit tone will sound and the display will show D $
3)
Press NO, then 1, 2 or 3 (for Part 1, 2 or 3). The bars on the display will
change to:-
The two bottom bars if Part 1 has been selected (D %)
The top and bottom bars if Part 2 has been selected(D &)
The bottom bar only if Part 3 has been selected (D ])
4)
The exit tone may or may not be heard dependant on the system settings.
5)
Exit the premises or retire to an unprotected part of the system. At the end
of the exit time either the exit tone will stop or a single beep will be emitted
(dependant on system settings).
Area Setting (using Master or Global Main codes)
1)
With the display showing T M Enter a Master or global Main code.
2)
The display will show R D (flashing) Press YES to start setting the system,
the exit tone will sound.
3)
To turn Area 1 Off press YES, 1 and / or
To turn Area 2 Off press YES, 2 and / or
To turn Area 3 Off press YES, 3 and / or
To turn Area 4 Off press YES, 4 and / or
To turn Area 5 Off press YES, 5 and / or
To turn Area 6 Off press YES, 6 and / or
To turn Area 7 Off press YES, 7 and / or
To turn the Cleaner Area Off press YES, 0
4)
Exit the premises or retire to an unprotected part of the system. At the end
of the exit time the exit tone will stop provided the system was clear.
Note:
Areas must first be programmed by the installation company.
Area Setting (using Area codes)
Area codes are only effective to their own area with the exception of the cleaner area
which may be turned off by an area code (only if all areas are in the unset condition).
Removing Zones
(Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code. It should be noted that if an Area
Main code is being used only zones associated with that area may be removed.
1)
With the display showing T M Enter a Master or Main level code.
2)
The display will show R D (flashing), press NO.
3)
The Display will show L D (flashing), press YES.
4)
The display will show L -
5)
Enter the zone number you wish to remove followed by YES.
The display will show L -
7)
If you wish to remove other zones return to step 5
Or
To escape press 0 the display will show R D (flashing).
8)
Press YES to start setting the system.
9)
Exit the premises or retire to an unprotected part of the system. At the end
of the exit time the exit tone will stop provided the system was clear.
Note:
Zone remove is only effective for the one set.
Testing The System
(Master & Main codes only)
1)
With the display showing T M
2)
Enter a Master or Main level code, the display will show R D (flashing).
3)
Press NO twice, the display will show D (flashing).
4)
Press YES, the display will show A press YES if you wish to test all areas
(or press NO until the area you wish to test is displayed then press YES)
5)
The display will show A (if all zones are clear).
6)
Whilst in test mode:-
Pressing 6 will silence the internal sounders
Pressing 4 will toggle the strobe On / Off
Pressing 9 will toggle the Bells On / Off
7)
When you have finished testing the system press 0 twice to return to the
Unset condition.
Viewing The Event Log (Master code only)
To get the full capability from the Log we recommend using an LCD keypad
1)
With the display showing T M enter a Master code.
2)
The display will show R D (flashing), press NO three times.
3)
The display will show K N (flashing).
4)
Press YES, the display may show for example A K this is the most recent
event.
5)
If you have a printer connected pressing 1 will toggle the printer On/Off
6)
Whilst viewing the Log :-
Pressing NO will move back to the previous event.
Pressing YES will move forwards to the next event.
Pressing 7 will take you back to the first event of the previous day.
Pressing 9 will take you forwards to the first event of the next day.
Pressing 3 will display the Date / Time in the format
Day of month (two digits)
Month (two digits)
Hour (two digits)
Seconds (two digits)
7)
When you have finished viewing the Log press 0 twice to return to the Unset
condition.
Note:
A complete list of possible LED displays is given in the section LED
Display Glossary.
Changing The Chime Status
(Master code only)
The Chime zones will have previously been programmed by your installation company.
A Master level code may change the status of the chime between On and Off. To do
so proceed as follows:-
1)
With the display showing T M enter a Master code
2)
The display will show R D (flashing)
3)
Press NO four times the display will show ( G
4)
Press YES, the display will show N E or N M
5)
Press NO to change the Chime status.
6)
When you have finished press 0 twice to return to the Unset condition.
Programming User Codes
User Codes may only be programmed via an LCD keypad
Programming Date & Time
Date & Time may only be programmed via an LCD keypad
User Initiating Remote Access
Users should only initiate Remote Access when instructed to do so by the installation
company.
1)
With the display showing T M enter a master level code then press NO
seven times the display will flash A Q
2)
Press YES the display will show VW (Wait) then C H (Dialling) then
( M (Connected).
3)
When the installation company has finished the display will return to T M
In the event of an error the display will show D Q you should try again
Resetting After An Alarm
Your installation company will have programmed the reset modes for your system so
that it complies to your insurance company and legislation requirements.
Your installation company will have informed you as to the type of reset that your
system is set for.
Before attempting to reset your system ensure that the system is Un-set.
1)
If the system is programmed for any code reset enter a user (followed by YES
if Master or Main code is used), the exit tone will sound and the display will
show for example D $
2)
Enter the code again to abort the setting.
3)
The system is now reset.
Or
If the display shows D Q when you attempt to reset it refer to the
programmed reset mode and take the appropriate action as follows:-
Reset Type
Action
Master Code
Use a Master code to set and abort setting
Engineer Code
Call the installation company.
Engineer + Anti-Code
Call the installation company.
Anti-Code
When you try to set the system make a note of
the four digit number given on the display,
call the installation company or central station for
an Anti-Code and proceed as shown from step 4
4)
To reset the system with an Anti-Code enter the number given by the central
station or installation company into the keypad (this may contain the YES &
NO keys).
5)
The system is now reset.
LED Display Glossary
Displays During Normal Use
T M
System Unset.
D $
The system is full setting.
$
The system is fully set.
D %
The system is part 1 setting.
%
The system is part 1 set.
D &
The system is part 2 setting.
&
The system is part 2 set.
D ]
The system is part 3 setting
]
The system is part 3 set
B$
The system is cleaner setting.
B$
The system is cleaner set.
AK
An alarm has occurred press NO
to view.
E B
Fuse blown or battery volts low.
( B
Control box tamper.
B B
bell box tamper.
D 1
Expander1 tamper (may show
1 to 16).
O K
Telephone Line fault (or coms
fail).
O B
Power Cut.
S 4
Tamper keypad 4 (may show
1 to 4).
D Q
Reset is required by a higher
level code or an error has
occurred whilst programming.
A B
Reset by Anti-Code is required.
R D
(flashing) Do you want to Set.
rD
Remove zones.
D
Test system.
( G
Change Chime.
T B
Program User codes.
C S
Program date time.
K N
Log
] ]
Waiting for numeric input.
VW
Wait, system in use.
D M
Engineer code reset required.
D M
(flashing) Call Engineer
Displays Whilst Viewing Log
Please be aware not all Log Events
can be viewed on an LED keypad. We
recommend the use of an LCD keypad.
04
Alarm occurred because of zone
4 was activated.
04
Alarm occurred because of
tamper on zone 4.
04
(flashing) zone 4 was removed.
K Q
Telephone Line restored.
O Q
Power restored.
C 3
Duress code by user 3.
'rD '
Watchdog reset.
A r
Alarm was reset.
B N
bells on.
0 1
User code 1 used (may show
1 to 47).
E 2
Fire activated from alert keys on
keypad 2.
A 2
Alert activated from alert keys on
keypad 2.
O 2
Panic activated from alert keys
on keypad 2.
E
A zone on test has failed.
Q K
read Log.
Page 31
GARDTEC 872
User Manual
System Attributes
Zone No.
Zone Type
Descriptor
Areas
Part Info
Example
E/E
Front Door
1&2
A1 Pt2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
21
22
23
24
25
26
27
28
31
32
33
34
35
36
37
38
41
42
43
44
45
46
47
48
Page 32
GARDTEC 872
User Manual
51
52
53
54
55
56
57
58
61
62
63
64
65
66
67
68
71
72
73
74
75
76
77
78
81
82
83
84
85
86
87
88
91
92
93
94
95
96
97
98
101
102
103
104
105
106
107
108
Page 33
GARDTEC 872
User Manual
111
112
113
114
115
116
117
118
121
122
123
124
125
126
127
128
131
132
133
134
135
136
137
138
141
142
143
144
145
146
147
148
151
152
153
154
155
156
157
158
161
162
163
164
165
166
167
168
Alarm Reset Type:-
Tamper Reset Type:-
Please use this chart to indicate what user names have been programmed onto your
system and those that are in use.
Page 35
GARDTEC 872
User Manual
In Use Name
User 1
User 2
User 3
User 4
User 5
User 6
User 7
User 8
User 9
User 10
User 11
User 12
User 13
User 14
User 15
User 16
User 17
User 18
User 19
User 20
User 21
User 22
User 23
User 24
User 25
User 26
User 27
User 28
User 29
User 30
User 31
User 32
User 33
User 34
User 35
User 36
User 37
User 38
User 39
User 40
User 41
User 42
User 43
User 44
User 45
User 46
User 47
User 48
In Use Name
User 49
User 50
User 51
User 52
User 53
User 54
User 55
User 56
User 57
User 58
User 59
User 60
User 61
User 62
User 63
User 64
User 65
User 66
User 67
User 68
User 69
User 70
User 71
User 72
User 73
User 74
User 75
User 76
User 77
User 78
User 79
User 80
User 81
User 82
User 83
User 84
User 85
User 86
User 87
User 88
User 89
User 90
User 91
User 92
User 93
User 94
User 95
User 96
User 97
User 98
User 99
ACE User Instructions
ACE (Advanced Control Equipment) allows control of your Gardtec 872 system via
Infra-Red Remote control. Ace is available built in to a range of keypads or as a stand
alone unit, control is via neat remote keyfob(s).
We strongly advise that User Number 1 is not used for ACE in order that the user
retains control of the programming functions.
Setting the System with ACE
1)
Point the keyfob at the ACE receiver and press the button.
2)
When the exit tone sounds exit the premises in the usual way.
Part Setting the System with ACE
1)
Point the keyfob at the ACE receiver and press the button.
2)
When you hear the exit tone press the keyfob button again
(within 3 seconds) for Part Set 1.
or
Press 1, 2 or 3 on the receiver/keypad for the Part Set you require.
Unsetting the System with ACE
1)
Enter the premises via an authorised entry point.
2)
Point the keyfob at the receiver and press the button.
User Manual
Keyfobs onto your System
Two modes are available for ACE, these are ‘Normal’ & ‘High’ Security. Please check
the User Information Chart on page 2 noting the mode of your ACE control.
Normal Security
In this mode up to fourteen keyfobs may be programmed onto a single user number
1)
Follow the procedure for programming user codes to the point when the user
code is entered.
2)
Point the keyfob at the ACE unit and press the button on the fob.
3)
Repeat this procedure for any other fobs you wish to be programmed using
the same user number each time (e.g User 1 or User 2 etc.) each time.
4)
If more than one ACE receiver is fitted fobs need to be programmed onto all
ACE receivers, yet again the same user number should be used.
Note:
When programming the fob onto more than one receiver (on the same
system) the button on the fob MUST be held down continuously
between programming onto the first and subsequent ACE receivers.
High Security
In this mode each keyfob will occupy a User number. The number of keyfobs that may
be used is limited by the maximum number of user codes available on the system up
to a maximum of fourteen.
1)
Follow the procedure for programming user codes to the point when the user
code is entered.
2)
Point the keyfob at the ACE unit and press the button on the fob.
3)
Repeat this procedure for any other fobs you wish to be programmed using
a different user number each time (e.g User 1 or User 2 etc.) each time.
4)
If more than one ACE receiver is fitted fobs need to be programmed onto all
ACE receivers, retaining the same user number for each individual fob.
Note:
When programming the fob onto more than one receiver (on the same
system) the button on the fob MUST be held down continuously
between programming onto the first and other ACE receivers.
Note:
In all cases when the ACE is used only Master & Main user levels will
allow part setting via the keyfob. Other code levels will only allow part
setting in conjunction with the keypad.
Page 38
GARDTEC 872
User Manual