Risco GARDTEC 872 User Instructions

Text of the manual

User Information .........................................................

2 Using LCD Keypads Introduction ................................................................... 3 User Code Types.......................................................... 3 Duress Codes ............................................................... 4 Setting The System ...................................................... 5 Setting & Unsetting via a Keyswitch ............................. 5 Unsetting The System .................................................. 6 Part Setting The System............................................... 6 - 7 Area Setting .................................................................. 8 Removing Zones........................................................... 9 Testing The System...................................................... 10 Viewing The Event Log................................................. 11 - 12 Changing The Chime Status......................................... 12 - 13 Programming User Codes ............................................ 14 - 16 Programming Time & Date ........................................... 17 User Initiating Remote Access ..................................... 18 Resetting After An Alarm .............................................. 19 - 20 Using LED Keypads.................................................... 21 Setting The System ...................................................... 21 Unsetting The System .................................................. 21 Part Setting The System............................................... 22 Area Setting .................................................................. 23 Removing Zones........................................................... 23 - 24 Testing The System...................................................... 24 Viewing The Event Log................................................. 25 Changing The Chime Status......................................... 26 Programming User Codes ............................................ 26 User Initiating Remote Access...................................... 27 Resetting After An Alarm .............................................. 28 LED Display Glossary................................................... 29 - 30 System Attributes.......................................................... 31 - 34 Service Record ............................................................. 34 User Chart .................................................................... 35 - 36 ACE Instructions ........................................................... 37 Programming ACE Keyfobs onto your System............. 38 Page 1 GARDTEC 872 User Manual

GARDTEC 800 Series

User Manual User Information Customer Name:- Customer Address:- Control Panel Model No of Keypads Keypad 1 Location Type Keypad 2 Location Type Keypad 4 Location Type Keypad 5 Location Type Keypad 6 Location Type Keypad 7 Location Type Keypad 8 Location Type ACE Mode (if fitted) Normal Security High Security Keyswitch 1 Location Reserved User Code User No. Keyswitch 2 Location Reserved User Code User No. Keyswitch 3 Location Reserved User Code User No. Keyswitch 4 Location Reserved User Code User No. Keyswitch 5 Location Reserved User Code User No. Keyswitch 6 Location Reserved User Code User No. Keyswitch 7 Location Reserved User Code User No. Keyswitch 8 Location Reserved User Code User No. Installation Company Name:- Installation Company Address:- Installation Company Tel. Fax. Other Information:- Note: Please ensure this section is completed by the installation engineer

GARDTEC 800 Series

User Manual Introduction The Gardtec 872 control panel is a multi zone microprocessor controlled unit. Two types of display are available for the system keypads, a) LCD offering a 32 character display with zone descriptors and user names or, b) Twin seven segment LED displays offering limited control/user programming options. The LED type displays normally used for setting and unsetting at secondary points. Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual. User Code Types 99 user codes are available offering 19 code types with varying levels of access to the system. User number 1 will always be a Master Level User but the remaining User Codes may be programmed (by a Master Code) to the required level of access. These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are:- Master Allows Setting, Unsetting, Zone Remove (if programmed by engineer), Test System, View Log, Chime On/Off, User Codes, Set Time/Date, Reset After Alarm (if programmed by engineer), Unsetting. Cleaner Full System Setting (from unset system), Cleaner Area Unsetting (from set system), Cleaner Part Set (from part cleaner set system). Area 1 to 7 User Allows Area 1 to 7 Setting, Area 1 to 7 Part Setting, Area 1 to 7 Unsetting. Main User Allows Setting, Part Setting, Zone Remove (if programmed & Main User 1 to 7 by engineer), System Test, Unsetting, Reset after Alarm (if programmed by engineer). Main User 1 to 7 are specific to their area. Control Used for control of other equipment (see installation company for details). Set Only Only Allows for the setting of the system. Note: For information on using Duress on the Gardtec 872 see Using Duress Section.

Duress Codes may be programmed onto your GardTec 872 system. When used a

Duress code will appear to operate the security system in the normal way but will also send a PA (personal attack) signal to central station (if programmed). One of two types of Duress codes may be programmed onto your system. a) Add 1 to the first digit of any User Code e.g the normal User Code is 5678 so the Duress code for this User would be 6678. If programmed to this type of Duress by the engineer the 1 digit increment will apply to all User Codes on the system. b) User 7 Duress. Any code that is programmed as User number 7 will be the Duress code for that system. Your installation company will advise you on the type of Duress codes that are programmed on your system and the correct use of those codes.

Setting The System

1) With the display showing:- 2) Enter the User code (followed by YES if Master or Main type code has been used). The display will show for example:- and a continuous exit tone will sound 3) Exit the premises via the authorised exit route (the exit tone will change if any detectors are violated during exit) 4) Once the premises are secure listen that the exit tone returns to the continuous tone. 5) Wait until the exit tone finishes before leaving. Note: Setting the system with an area code will set only the area associated with that code. Note: Setting an unset system with a cleaner code will set the full system. Setting & Unsetting the System via a Keyswitch One of two types of keyswitch(es) may have been fitted to your system. Normal To set the system with a normal keyswitch, insert the key and turn to the ON position then remove the key. To unset insert the key and turn to the OFF position. Biased To set the system with a biased keyswitch, insert the key and turn it then return the key to the original position and remove. To unset repeat this operation. < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 EXIT Now ! 1 2 3 C All Zones ON 15

Unsetting The System

1) Enter the premises via the authorised entry route (the broken entry tone will sound), proceed to the keypad. 2) At the keypad enter a valid code, the display will show:- 3) The system is now unset. Note: If an Area Code has been entered only the area associated with that code will be unset. Note: If a Cleaner Code has been entered only the cleaner area will be unset. Note: For DD243 systems ACE keyfobs may have to be used to unset the system, chexk with your installation company. Note: In the event of the system being set using ACE when the battery is low the display will show ACE Battery Low when the system is unset press Yes to clear the display and change the battery in the keyfob. Part Setting The System (using Master & Main type codes) 1) With the display showing:- 2) Enter a Master or Main type code, the display will show for example:- 3) Press 1, 2 or 3 (for Part 1, 2 or 3), the display will show for example:- Note: If a Global code (Master or Main) has been used all areas that are being set will be Part 1 set. Note: If an Area Main code has been used only Part 1 set for that associated area will occur. < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set , STUART ? EXIT Now! 1 2 3 C Part 1 15

The exit tone may or may not be heard

dependant on the system settings. 5) Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (dependant on system settings). Part Setting System (using Area 1 to 7 codes) 1) With the display showing:- 2) Enter an Area Code (1to 7), the exit tone will sound and the display will show for example:- 3) Press NO then 1, 2 3 (for the Part Set you require), the display will show for example:- 4) The exit sounders may or may not go silent this will depend on the system settings. 5) Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (dependant on system settings). < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 EXIT Now ! 1 All Zones ON 15 EXIT Now ! 1 Part 1 20

(using Master or global Main codes)

Areas will need to have been set up by the installation company. 1) With the display showing:- 2) Enter a Master or global Main code, the display will show for example:- 3) Press YES to start setting the system, the exit tone will sound and the display will show:- 4) To turn Area 1 Off press YES, 1 and / or To turn Area 2 Off press YES, 2 and / or To turn Area 3 Off press YES, 3 and / or To turn Area 4 Off press YES, 3 and / or To turn Area 5 Off press YES, 3 and / or To turn Area 6 Off press YES, 3 and / or To turn Area 7 Off press YES, 3 and / or To turn the Cleaner Area Off press YES, 0 As areas are turned off they will be removed from the display. 5) Exit the premises or retire to an un-protected area (as detectors are violated the continuous exit tone will change). Note: Areas must first be programmed by the installation company before they will appear on the display. Area Setting (using Area codes) Area codes are only effective to their own area with the exception of the cleaner area. This may be turned off by an area code (only if all areas are in the unset condition). Use is the same as Setting the system shown on page 5 but only the relevant area will be set < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set. ELIZABETH ? EXIT Now ! 1 2 3 C All Zones ON 30

Removing Individual Zones

(Master & Main codes only) If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. It should be noted that if an Area Main code is being used, only zones associated with that area may be removed. 1) With the display showing:- 2) Enter a Master or Main level code, the display will show:- 3) Press NO, the display will show:- 4) Press YES, the display will show:- 5) Enter the zone number you wish to remove followed by YES (pressing NO will 'un-remove' a zone), the display will show:- 6) Repeat step 5 until you have removed all the required zones. 7) Press 0 to escape, the display will show:- 8) Press YES, the continuous exit tone will sound. 9) Exit the premises via the authorised exit route ( the exit tone will change as detectors are violated). When the premises are secure listen that the exit tone returns to the continuous tone. Wait until the exit tone finishes before leaving. Note: Zone remove is only effective for the one set. < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . Set . STUART ? Do you want to . . REMOVE Zones ? Enter Zone No. - - then + YES or - NO Enter Zone No. - - then + YES or - NO

Testing The System

(Master & Main codes only) 1) With the display showing:- 2) Enter a Master or Main level code, the display will show:- 3) Press NO, the display will show:- 4) Press NO, the display will show:- 5) Press YES, the display will show:- 6) Press YES to test the full system or NO until the area you wish to test is shown 7) Press YES, the display will show:- for 3 seconds Then for example:- 8) Pressing 1 will enter zone Status mode (All zones will show on the display and will be deleted as each zone is triggered). Press 0 to escape. Pressing 6 will silence the internal sounder, Pressing 4 will toggle the Strobe On/Off, Pressing 9 will toggle the Bell On/Off < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . REMOVE Zones ? Do you want to . . TEST the System ? Test ALL Areas ? 1=Status 4 = Strobe 6 = Sounder 9 = Bell < All Zones OK > TESTING . . .

Whilst in Test mode any zones violated

will sound the internal sounder (if it has not been silenced) and show on the display. 10) When you have finished testing the system press 0 twice, the display will show:- Viewing The Event Log (Master code only) 1) With the display showing:- 2) Enter a Master Code, the display will show for example:- 3) Press NO three times, the display will show:- 4) Press YES, the display will show:- for 3 seconds Then, for example:- < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . View the LOG ? While Viewing . . . 1 = Printer On / Off Read Log 01 JAN 18 : 58 : 01

This is the most recent event in the log.

Whilst viewing the Log, Pressing NO will move back to the previous event. Pressing YES will move forward to the next event. Pressing 7 will take you to back to the last event of the previous day. Pressing 9 will take you forward to the first event of the next day. 6) When you have finished viewing the Log press 0 twice the display will show:- Changing The Chime Status (Master code only) The Chime zones will have previously been programmed by the installation company. A Master level code may change the status of the Chime between On and Off. To do so proceed as follows:- 1) With the display showing:- 2) Enter a Master Code, the display will show for example:- 3) Press NO four times, the display will show:- < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . Change Chime ?

Press YES the display will show for example:-

Or:- 5) Press NO to change the status of the Chime, then press YES, the display will show:- 6) Press 0 to escape, the display will show:- Chime is Off ok ? Chime is On ok ? Do you want to . . Change Chime ? < < < < UN-SET > > > > 01 JAN 18 : 58 : 01

Programming User Codes

(Master code only) The charts on pages 2 & 35 should be completed by the engineer/user for future reference of what codes have been allocated on your system. Under no circumstances should the actual user code be written down. If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches. If your engineer has indicated (see pages 2 & 35) that some of the user numbers on your system have been reserved you should not use them whilst programming user codes. If you do so your system may be adversely affected 1) With the display showing:- 2) Enter a Master Code, the display will show:- 3) Press NO five times, the display will show:- 4) Press YES, the display will show:- 5) Enter the user number (1 to 99 ) that you wish to program followed by YES, the display will show:- At this point the display may ask if this code is for ACE (Keyfob) dependant on the system settings. Press Yes or No as required if this question is asked. < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . Prog. USER CODES ? Enter User No. - - (1- 99) Then YES Now Enter Code . . - - - - - - Then YES

Enter the code you require (codes may be 4,

5 or 6 digits) followed by YES. (Entering 000000 will delete an existing code) Note: If the code already exists or is a duress of another code an error will be shown, choose another code and return to step 6 7) The display will show:- (not if user 1 is being programmed). 8) Press No until the level of code you require is displayed then press Yes. The display will show for example:- 9) If you wish to accept the name shown press YES and jump to step 13 Or If you wish to change the name shown press NO, the display will show:- 10) You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters. User 02 Name = USER 02 User 1 Name > 1 2 3 4 5 6 7 8 9 0 YES NO ABC DEF GHI JKL MNO PQR STU VWX YZ 0-9 Code Type = Master ok ?

Referring to the character map enter the required

character (pressing the 3 key will display 'G', pressing it again will show 'H' and again will show 'I '), once the correct character is displayed press YES and the display will move on to the next position. 12) Continue entering characters (up to 9). If you require a blank space press YES while the '-' is displayed to show the space this will not be displayed after programming is completed. 13) As you press YES for the ninth character (or if you have jumped from step 9) the display will change to:- 14) If you wish to program other User Codes return to step 4 Or Press 0 to return to:- Do you want to . . Prog. USER CODES ? < < < < UN-SET > > > > 01 JAN 18 : 58 : 01

Programming Time & Date

1) With the display showing:- 2) Enter a Master Code, the display will show:- 3) Press NO six times, the display will show:- 4) Press YES the display will show:- 5) For UK use press Yes. The display will show:- 6) Press No. The display will show:- 7) Enter the last two digits of the year e.g 03 if the year is 2003 then Yes. The display will show:- 8) Press Yes. Display will show:- 9) Enter the Day and Month e.g 11 / 09 for the 11th September then press Yes. The display will show:- 10) Enter the current Time using the 24Hr format e.g 20:30 for 8:30pm then press Yes. The display will show:- 11) Press 0 the display will show:- < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . Set DATE / TIME ? Summer - Adjust is On ok ? Year is 2000 ok ? Enter Year 20-- Then YES Year is 2003 ok ? Enter Day / Month - - / - - Then YES Enter Hours : Mins - - / - - Then YES Do you want to . . . Set Time / Date

User Initiating Remote Access (Optional)

Access Remote allows your installation company to examine your system and re- program system settings as you need the changes without the need for an engineer to visit your premises. If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call (usually on lines with incoming calls barred). To initiate the Remote Call follow the instructions below. 1) Negotiate with your installation company when you should initiate the Remote Call. 2) With the display showing:- 3) Enter a Master Code, the display will show for example:- 4) Press NO seven times, the display will show:- 5) Press YES the display will show:- Until Dialling commences Then:- Until Connection Then:- 6) When your installation company has finished the display will show:- Note: In the event of any errors the display will show:- < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 Do you want to . . Set . STUART ? Do you want to . . Access Remote ? Please WAIT Please WAIT Dialling Please WAIT Connect < < < < UN-SET > > > > 01 JAN 18 : 58 : 01 ! ! ! ! ERROR ! ! ! ! Try Again . . . .

Resetting After an Alarm

Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements. Your installation company will have informed you as to the type of reset that your system is set for. Before attempting to reset your system ensure that the system is Un-set. 1) If the system is programmed for any code reset enter a user (followed by YES if Master or Main code is used), the exit tone will sound and the display will show for example:- 2) Enter the code again to abort the setting 3) The system is now reset Or If a higher level of code is required one of the following displays will be shown:- Use a Master code to reset the system. Or:- Call the installation company Or:- Call the installation company and quote the number given Or:- Call the installation company and quote the number given Or:- Can't Set Use Master Code Can't Set Use ENGNR Code Can't Set Use ENG +Anti Code 1234 Can't Set Use Anti Code 1234 EXIT Now ! 1 2 3 C All Zones ON 15

To reset the system with an anti-Code, contact

the central station or engineer (as instructed by the installation company) and quote the source given by the display. 5) The central station or engineer will give a return Anti-Code ( this may contain the YES & NO keys) for example 5, YES, 2, 4. 6) Enter this Anti-Code into the keypad 7) The system is now reset.

Using LED Keypads

This section is dedicated to using LED keypads (Twin Seven Segment). Setting The System 1) With the display showing T M 2) Enter the User Code (followed by YES if Master or Main type code has been used). 3) The display will show D $ and the exit tone will sound. Exit the premises via the authorised exit route (the exit tone will change if any detectors are violated during exit). 4) Once the premises are secure listen that the exit tone returns to the continuous tone. 5) Wait until the exit tone finishes before leaving. Note: Setting the system with an area code will set only the area associated with that code. Note: Setting an unset system with a cleaner code will set the full system. Unsetting The System 1) Enter the premises via the authorised entry route (the broken entry tone will sound). 2) Proceed to the keypad, enter a valid user code, the display will show T M. 3) The system is now Unset. Note: If an area code has been entered only the area associated with that code will be Unset. Note: If a cleaner code has been entered only the cleaner area will be Unset. Note: In the event of the system being set using ACE when the battery is low the display will show A B when the system is unset press Yes to clear the display and change the battery in the keyfob.

Part Setting The System

(using Master & Main type codes) 1) With the display showing T M Enter a Master or Main type code 2) The display will show R D (flashing). Press 1, 2 or 3 (for Part 1, 2 or 3) the display will show the D and:- The two bottom bars if Part 1 has been selected (D %) The top and bottom bars if Part 2 has been selected (D &) The bottom bar only if Part 3 has been selected (D ]) Note: If a Global code (Master or Main) has been used all areas that are being set would be Part Set. Note: If an Area Main code has been used only the Part Set associated with that area would be Part Set. 3) The exit tone may or may not be heard dependant on the system settings. 4) Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit tone will stop or a single beep will be emitted (dependant on system settings). Part Setting System (using Area 1, 2 or 3 codes) 1) With the display showing ' Un ' Enter an Area code (1, 2,3, 4, 5, 6, 7). 2) The exit tone will sound and the display will show D $ 3) Press NO, then 1, 2 or 3 (for Part 1, 2 or 3). The bars on the display will change to:- The two bottom bars if Part 1 has been selected (D %) The top and bottom bars if Part 2 has been selected(D &) The bottom bar only if Part 3 has been selected (D ]) 4) The exit tone may or may not be heard dependant on the system settings. 5) Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit tone will stop or a single beep will be emitted (dependant on system settings).

Area Setting (using Master or Global Main codes)

1) With the display showing T M Enter a Master or global Main code. 2) The display will show R D (flashing) Press YES to start setting the system, the exit tone will sound. 3) To turn Area 1 Off press YES, 1 and / or To turn Area 2 Off press YES, 2 and / or To turn Area 3 Off press YES, 3 and / or To turn Area 4 Off press YES, 4 and / or To turn Area 5 Off press YES, 5 and / or To turn Area 6 Off press YES, 6 and / or To turn Area 7 Off press YES, 7 and / or To turn the Cleaner Area Off press YES, 0 4) Exit the premises or retire to an unprotected part of the system. At the end of the exit time the exit tone will stop provided the system was clear. Note: Areas must first be programmed by the installation company. Area Setting (using Area codes) Area codes are only effective to their own area with the exception of the cleaner area which may be turned off by an area code (only if all areas are in the unset condition). Removing Zones (Master & Main codes only) If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. It should be noted that if an Area Main code is being used only zones associated with that area may be removed. 1) With the display showing T M Enter a Master or Main level code. 2) The display will show R D (flashing), press NO. 3) The Display will show L D (flashing), press YES. 4) The display will show L - 5) Enter the zone number you wish to remove followed by YES.

The display will show L -

7) If you wish to remove other zones return to step 5 Or To escape press 0 the display will show R D (flashing). 8) Press YES to start setting the system. 9) Exit the premises or retire to an unprotected part of the system. At the end of the exit time the exit tone will stop provided the system was clear. Note: Zone remove is only effective for the one set. Testing The System (Master & Main codes only) 1) With the display showing T M 2) Enter a Master or Main level code, the display will show R D (flashing). 3) Press NO twice, the display will show   D (flashing). 4) Press YES, the display will show   A press YES if you wish to test all areas (or press NO until the area you wish to test is displayed then press YES) 5) The display will show   A (if all zones are clear). 6) Whilst in test mode:- Pressing 6 will silence the internal sounders Pressing 4 will toggle the strobe On / Off Pressing 9 will toggle the Bells On / Off 7) When you have finished testing the system press 0 twice to return to the Unset condition.

Viewing The Event Log (Master code only)

To get the full capability from the Log we recommend using an LCD keypad 1) With the display showing T M enter a Master code. 2) The display will show R D (flashing), press NO three times. 3) The display will show K N (flashing). 4) Press YES, the display may show for example A K this is the most recent event. 5) If you have a printer connected pressing 1 will toggle the printer On/Off 6) Whilst viewing the Log :- Pressing NO will move back to the previous event. Pressing YES will move forwards to the next event. Pressing 7 will take you back to the first event of the previous day. Pressing 9 will take you forwards to the first event of the next day. Pressing 3 will display the Date / Time in the format Day of month (two digits) Month (two digits) Hour (two digits) Seconds (two digits) 7) When you have finished viewing the Log press 0 twice to return to the Unset condition. Note: A complete list of possible LED displays is given in the section LED Display Glossary.

Changing The Chime Status

(Master code only) The Chime zones will have previously been programmed by your installation company. A Master level code may change the status of the chime between On and Off. To do so proceed as follows:- 1) With the display showing T M enter a Master code 2) The display will show R D (flashing) 3) Press NO four times the display will show ( G 4) Press YES, the display will show N E or N M 5) Press NO to change the Chime status. 6) When you have finished press 0 twice to return to the Unset condition. Programming User Codes User Codes may only be programmed via an LCD keypad

Programming Date & Time

Date & Time may only be programmed via an LCD keypad User Initiating Remote Access Users should only initiate Remote Access when instructed to do so by the installation company. 1) With the display showing T M enter a master level code then press NO seven times the display will flash A Q 2) Press YES the display will show VW (Wait) then C H (Dialling) then ( M (Connected). 3) When the installation company has finished the display will return to T M In the event of an error the display will show D Q you should try again

Resetting After An Alarm

Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements. Your installation company will have informed you as to the type of reset that your system is set for. Before attempting to reset your system ensure that the system is Un-set. 1) If the system is programmed for any code reset enter a user (followed by YES if Master or Main code is used), the exit tone will sound and the display will show for example D $ 2) Enter the code again to abort the setting. 3) The system is now reset. Or If the display shows D Q when you attempt to reset it refer to the programmed reset mode and take the appropriate action as follows:- Reset Type Action Master Code Use a Master code to set and abort setting Engineer Code Call the installation company. Engineer + Anti-Code Call the installation company. Anti-Code When you try to set the system make a note of the four digit number given on the display, call the installation company or central station for an Anti-Code and proceed as shown from step 4 4) To reset the system with an Anti-Code enter the number given by the central station or installation company into the keypad (this may contain the YES & NO keys). 5) The system is now reset.

LED Display Glossary

Displays During Normal Use T M System Unset. D $ The system is full setting. $ The system is fully set. D % The system is part 1 setting. % The system is part 1 set. D & The system is part 2 setting. & The system is part 2 set. D ] The system is part 3 setting ] The system is part 3 set B$ The system is cleaner setting. B$ The system is cleaner set. AK An alarm has occurred press NO to view. E B Fuse blown or battery volts low. ( B Control box tamper. B B bell box tamper. D 1 Expander1 tamper (may show 1 to 16). O K Telephone Line fault (or coms fail). O B Power Cut. S 4 Tamper keypad 4 (may show 1 to 4). D Q Reset is required by a higher level code or an error has occurred whilst programming. A B Reset by Anti-Code is required. R D (flashing) Do you want to Set. rD Remove zones.   D Test system. ( G Change Chime. T B Program User codes. C S Program date time. K N Log ] ] Waiting for numeric input. VW Wait, system in use. D M Engineer code reset required. D M (flashing) Call Engineer

Displays Whilst Viewing Log

Please be aware not all Log Events can be viewed on an LED keypad. We recommend the use of an LCD keypad. 04 Alarm occurred because of zone 4 was activated. 04 Alarm occurred because of tamper on zone 4. 04 (flashing) zone 4 was removed. K Q Telephone Line restored. O Q Power restored. C 3 Duress code by user 3. 'rD ' Watchdog reset. A r Alarm was reset. B N bells on. 0 1 User code 1 used (may show 1 to 47). E 2 Fire activated from alert keys on keypad 2. A 2 Alert activated from alert keys on keypad 2. O 2 Panic activated from alert keys on keypad 2.   E A zone on test has failed. Q K read Log.

Page 31 GARDTEC 872 User Manual System Attributes Zone No. Zone Type Descriptor Areas Part Info Example E/E Front Door 1&2 A1 Pt2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 21 22 23 24 25 26 27 28 31 32 33 34 35 36 37 38 41 42 43 44 45 46 47 48

Page 32 GARDTEC 872 User Manual 51 52 53 54 55 56 57 58 61 62 63 64 65 66 67 68 71 72 73 74 75 76 77 78 81 82 83 84 85 86 87 88 91 92 93 94 95 96 97 98 101 102 103 104 105 106 107 108

Page 33 GARDTEC 872 User Manual 111 112 113 114 115 116 117 118 121 122 123 124 125 126 127 128 131 132 133 134 135 136 137 138 141 142 143 144 145 146 147 148 151 152 153 154 155 156 157 158 161 162 163 164 165 166 167 168

Alarm Reset Type:-

Tamper Reset Type:-

Please use this chart to indicate what user names have been programmed onto your

system and those that are in use. Page 35 GARDTEC 872 User Manual In Use Name User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12 User 13 User 14 User 15 User 16 User 17 User 18 User 19 User 20 User 21 User 22 User 23 User 24 User 25 User 26 User 27 User 28 User 29 User 30 User 31 User 32 User 33 User 34 User 35 User 36 User 37 User 38 User 39 User 40 User 41 User 42 User 43 User 44 User 45 User 46 User 47 User 48

In Use Name

User 49 User 50 User 51 User 52 User 53 User 54 User 55 User 56 User 57 User 58 User 59 User 60 User 61 User 62 User 63 User 64 User 65 User 66 User 67 User 68 User 69 User 70 User 71 User 72 User 73 User 74 User 75 User 76 User 77 User 78 User 79 User 80 User 81 User 82 User 83 User 84 User 85 User 86 User 87 User 88 User 89 User 90 User 91 User 92 User 93 User 94 User 95 User 96 User 97 User 98 User 99

ACE User Instructions

ACE (Advanced Control Equipment) allows control of your Gardtec 872 system via Infra-Red Remote control. Ace is available built in to a range of keypads or as a stand alone unit, control is via neat remote keyfob(s). We strongly advise that User Number 1 is not used for ACE in order that the user retains control of the programming functions. Setting the System with ACE 1) Point the keyfob at the ACE receiver and press the button. 2) When the exit tone sounds exit the premises in the usual way. Part Setting the System with ACE 1) Point the keyfob at the ACE receiver and press the button. 2) When you hear the exit tone press the keyfob button again (within 3 seconds) for Part Set 1. or Press 1, 2 or 3 on the receiver/keypad for the Part Set you require. Unsetting the System with ACE 1) Enter the premises via an authorised entry point. 2) Point the keyfob at the receiver and press the button. User Manual

Keyfobs onto your System

Two modes are available for ACE, these are ‘Normal’ & ‘High’ Security. Please check the User Information Chart on page 2 noting the mode of your ACE control. Normal Security In this mode up to fourteen keyfobs may be programmed onto a single user number 1) Follow the procedure for programming user codes to the point when the user code is entered. 2) Point the keyfob at the ACE unit and press the button on the fob. 3) Repeat this procedure for any other fobs you wish to be programmed using the same user number each time (e.g User 1 or User 2 etc.) each time. 4) If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers, yet again the same user number should be used. Note: When programming the fob onto more than one receiver (on the same system) the button on the fob MUST be held down continuously between programming onto the first and subsequent ACE receivers. High Security In this mode each keyfob will occupy a User number. The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen. 1) Follow the procedure for programming user codes to the point when the user code is entered. 2) Point the keyfob at the ACE unit and press the button on the fob. 3) Repeat this procedure for any other fobs you wish to be programmed using a different user number each time (e.g User 1 or User 2 etc.) each time. 4) If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers, retaining the same user number for each individual fob. Note: When programming the fob onto more than one receiver (on the same system) the button on the fob MUST be held down continuously between programming onto the first and other ACE receivers. Note: In all cases when the ACE is used only Master & Main user levels will allow part setting via the keyfob. Other code levels will only allow part setting in conjunction with the keypad. Page 38 GARDTEC 872 User Manual

Other Keypad Manuals