Key Pages of Document

Visit ni.com/register to register your National Instruments product. Product registration

facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certifica ...

Hardware Front Panel Connectors and Indicators

NI PXI-5690 IN CH 0 OUT IN +20 dBm MAX With ATTN 50 Ω +20 dBm MAX With ATTN 50 Ω -20 dBm MAX With ATTN 50 Ω +20 dBm MAX With ATTN 50 Ω CH 1 OUT 100 kHz-3.0 GHz ACCESS ACTIVE Table 1. NI 5690 Front Panel Connectors Connector Access Function CH 0 IN Input CH 0 IN and CH 0 OUT each function as a fixed-gain amplifier. These channels offer a low noise figure and a flat frequency response. CH 0 IN and CH 0 OUT are AC-coupled. CH 0 OUT Output 8 | ni.com | NI PXI-5690 Getting Started Guide ...

In the Configuration pane, double-click Devices and Interfaces to see the list of installed

devices. Installed devices appear under the name of their associated chassis. Note If you are using the NI 5690 with the LabVIEW Real-Time Module, expand Remote Systems. Find your target IP address or name, expand it, and then expand Devices and Interfaces. 3. Expand your Chassis tree item. MAX lists all devices installed in the chassis. Your default device names may vary. Note If you do not see your hardware listed, press to refresh the list of installed devices. If the device is still not li ...

Table 1. NI 5690 Front Panel Connectors (Continued)

Connector Access Function CH 1 IN Input CH 1 IN and CH 1 OUT each function as a programmable amplifier with switchable main and direct paths. The main path offers fixed gain amplification preceded by a step attenuator that is adjustable in 1 dB nominal steps.1 The direct path bypasses the programmable circuitry and routes the signal directly to the output. The direct path passes DC level to output, whereas the main path is AC-coupled. CH 1 OUT Output Table 2. NI 5690 Front Panel LED Indicators LED Indications ACCESS Indicates the basic hardwa ...

Perform the self-test again.

Why Is the ACCESS LED Off When the Chassis is On? The LEDs may not illuminate until the device has been configured in MAX. Before proceeding, verify that the NI 5690 appears in MAX. If the ACCESS LED fails to illuminate after you power on the chassis, a problem may exist with the chassis power rails, a hardware module, or the LED. Caution Apply external signals only while the NI 5690 is powered on. Applying external signals while the device is powered off may cause damage. 1. Disconnect any signals from the module front panels. 2. Power off the chassis. 3. Remo ...

Perform the self-test again.

Why Is the ACCESS LED Off When the Chassis is On? The LEDs may not illuminate until the device has been configured in MAX. Before proceeding, verify that the NI 5690 appears in MAX. If the ACCESS LED fails to illuminate after you power on the chassis, a problem may exist with the chassis power rails, a hardware module, or the LED. Caution Apply external signals only while the NI 5690 is powered on. Applying external signals while the device is powered off may cause damage. 1. Disconnect any signals from the module front panels. 2. Power off the chassis. 3. Remo ...

There are several required items not included in your device kit that you need to install or

operate the NI 5690. Required Items • A PXI chassis and chassis documentation. The NI PXI-1045 chassis is one available option for your device. For more information about compatible chassis options, refer to ni.com. • A PXI embedded controller or MXI controller system that meets the system requirements specified in this guide and chassis documentation. Optional Items • A 1 N · m standard SMA torque wrench (NI part number 780487-01). Installing the Software You must be an Administ ...

Hardware Front Panel Connectors and Indicators

NI PXI-5690 IN CH 0 OUT IN +20 dBm MAX With ATTN 50 Ω +20 dBm MAX With ATTN 50 Ω -20 dBm MAX With ATTN 50 Ω +20 dBm MAX With ATTN 50 Ω CH 1 OUT 100 kHz-3.0 GHz ACCESS ACTIVE Table 1. NI 5690 Front Panel Connectors Connector Access Function CH 0 IN Input CH 0 IN and CH 0 OUT each function as a fixed-gain amplifier. These channels offer a low noise figure and a flat frequency response. CH 0 IN and CH 0 OUT are AC-coupled. CH 0 OUT Output 8 | ni.com | NI PXI-5690 Getting Started Guide ...

National Instruments NI PXI-5690 user guide recommended for: SM40, SCXI-1102, FORZA, 120 Combo, LRX D01.

⚠️ Download Safety

The Amplifier Getting started manual (14 pages) is completely safe to download (last scan date: 29/04/2026).

Related PDF Instructions for National Instruments NI PXI-5690:

Amplifier Equipment: Frequently Requested

Have some Questions about National Instruments NI PXI-5690 Device?

Get valuable and actionable advices from other National Instruments NI PXI-5690 device users. Describe your problem or question, regarding the using of NI PXI-5690, in as much detail as possible, and other users will be able to answer you.