Sartorius Basiclite Series

Sartorius Gemlite Series Electronic Precision Balances and Precious Metal Scales Operating Instructions 98648-008-55

The Basiclite Series and Gemlite Series

from Sartorius offer precision balances/ scales with capacities ranging from 0.1 mg to 12 kg. These balances/ scales meet the highest requirements on the accuracy and reliability of weighing results through the following features:  Efficient filtering-out of unfavorable ambient conditions such as vibrations, drafts, etc.  Stable and reproducible results  Rugged, durable weighing system Basiclite balances and Gemlite scales save work and speed up simple routine applications through:  Ultrafast response times  Easy operation You can also choose from the following extra functions for simple applications:  Toggling between weight units  Net-total formulation (tare memory)  Counting  Weighing in percent  Averaging Contents Practical Use .................................. 2 Contents ........................................ 2 Warning and Safety Information ........ 2 Getting Started ................................ 3 Operating the Balance/ Scale Basic Weighing Function .................... 8 Calibration/ Adjustment ...................... 9 Application Programs Counting ........................................10 Weighing in Percent ..........................12 Weigh Averaging ............................14 Net-Total Formulation/ Second Tare Memory ........................16 Toggle Between Weighing Units ..........17 Configuring the Balance/ Scale Setting the Parameters (Menu Codes) ....18 Balance/ Scale Operating Menu (Overview) ......................................19 Error Codes ....................................20 Care and Maintenance ....................21 Instructions for Recycling ....................22 Overview Specifications....................................23 Accessories (Options) ........................26 C Marking ......................................27 Warning and Safety Information Read these operating instructions thoroughly before using your balance/ scale to prevent damage to the equipment. Keep these instructions in a safe place. Follow the instructions below to ensure safe and trouble-free operation of your balance/ scale: ! Make sure that the voltage rating printed on the AC adapter is identical to your local line voltage ! Use only a commercially available 9-volt battery or rechargeable battery ! Do not use this balance/ scale in a hazardous area/ location  The only way to turn the power off completely is to disconnect the AC adapter  Connect only Sartorius accessories and options, as these are optimally desi- gned for use with your balance/ scale.  Protect the AC adapter from contact with liquid. Do not open the balance/ scale housing. If the seal is broken, this will result in forfeiture of all claims under the manufacturer's warranty.

Do not miss out on the benefits of our

full warranty. Please contact your local Sartorius office or dealer for further information. Complete the warranty registration card, if available indicating the date of installation, and return the card to your Sartorius office or dealer. Storage and Shipping Conditions Do not expose the balance/ scale to shocks, vibration, moisture or extreme temperatures. Unpacking the Balance/ Scale  After unpacking the balance/ scale, check it immediately for any visible damage as a result of rough handling during shipment. $ If you see any sign of damage, proceed as directed in the chapter entitled Care and Maintenance, under the section on Safety Inspection. Save the box and all parts of the packaging until you have successfully installed your balance/ scale. Only the original packaging provides the best protection for shipment. Before packing your balance/ scale, unplug all connected cables to prevent damage. Equipment Supplied The equipment supplied includes the components listed below: BL210S, BL120S, BL60S, GC503  Balance/ scale  Weighing pan  Pan support  Shield ring  Shield plate  Dust cover  AC adapter  Gem tray (only with model GC503)  Calibration weight 100 g, F1 (only with model GC503) BL150S  Balance/ scale  Weighing pan  Pan support  Glass draft shield with cover  AC adapter Balances/ scales with a readability of 0.01g  Balance/ scale  Weighing pan  Pan support (only on models with a round weighing pan)  AC adapter

Your balance/ scale is designed to

provide reliable weighing results under normal ambient conditions. W hen choosing a location to set up your balance/ scale, observe the following so that you will be able to work with added speed and accuracy:  Set up the balance/ scale on a stable, even surface  Avoid placing the balance/ scale in close proximity to a heater or otherwise exposing the balance/ scale to heat or direct sunlight  Protect the balance/ scale from drafts that come from open windows or doors  Avoid exposing the balance/ scale to extreme vibrations during weighing  Protect the balance/ scale from aggressive chemical vapors  Do not expose the balance/ scale to extreme moisture over long periods Conditioning the Balance/ Scale: Moisture in the air can condense on the surfaces of a cold balance/ scale whenever it is brought into a substantially warmer place. If you transfer the balance/ scale to a warmer area, make sure to condition it for about 2 hours at room temperature, leaving it unplugged from AC power. Information on Radio Frequency Interference Warning! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference, when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference.

Setting up the Balance/ Scale

Balances/ Scales with an Analytical Draft Shield Chamber:  Place the components listed below inside the chamber in the order given:  Shield plate  Shield ring  Pan support  Weighing pan  Gem tray (only with model GC503) Balances/ Scales with a Glass Draft Shield:  Place the components listed below inside the chamber in the order given:  Draft shield base  place it on the balance so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place  Pan support  Weighing pan  Glass draft shield  Draft shield cover  place it on the balance so that the edge faces downwards Balances/ Scales with a Round Weighing Pan  Place the components listed below inside the chamber in the order given:  Pan support  Weighing pan Balances/ Scales with a Rectangular Weighing Pan:  Place the weighing pan on the balance/ scale

Connecting the Balance/ Scale to AC Power/

Safety Precautions Use only original Sartorius AC adapters:  for Europe: 6971948  for the RSA: 6971949  for the U.S.: 6971947  for Australia: 6971950  Insert the right-angle plug into the jack  The AC adapter rated to Class 2 can be plugged into any wall outlet without requiring any additional safety precautions The ground is connected to the balance/ scale housing, which can be additionally grounded for operation. Using a Non-Rechargeable/ Rechargeable Battery (not for models BL210S, BL120S, BL60S, BL150S, BL1500S, GC503, GM1502) $ A non-rechargeable or rechargeable battery is not included with the equipment supplied ! Use only a commercially available non- rechargeable or rechargeable 9-volt battery ! W hen using a rechargeable battery, always use an external charger to recharge the battery  Lay the balance/ scale on its side  Open the battery compartment: Lift the compartment cover  Insert the 9-volt (rechargeable) battery in the compartment $ Make sure to connect the positive and negative poles correctly ! All used batteries are classified as waste that requires special handling (not household waste). Dispose of rechargeable batteries in accordance with the applicable special waste disposal regulations.  Close the battery compartment: Press down on the cover until it clicks into place

Selecting the Line Voltage (Mains Voltage)

Use the following original AC adapters for selecting the line voltage:  AC adapter TNG8, order no. 6971951 (universal) or  AC adapter TNG8, order no. 6971952 (for the U.K.) Use the switch to toggle between 230 V and 115 V Leveling the Balance/ Scale (only for models BL210S, BL120S, BL60S, BL150S, BL1500S, GC503, GM1502) Level the balance/ scale any time you set it up in a new location. Use only the 2 front feet of the balance/ scale for leveling.  Turn the 2 rear feet until they are in position (only on models BL1500S and GM1502)  Turn the 2 front feet as shown here in the illustration until the air bubble is centered in the level indicator > In most cases, this will require several adjustment steps Anti-theft Locking Device To protect against theft, use the mounting lug on the rear panel of the balance/ scale. Secure the balance/ scale at the place of installation, for example with a chain or a lock

Operating the Balance/ Scale

Basic Weighing Function Available Features  Taring the balance/ scale You can tare the balance/ scale within the entire weighing range. Preparation  Turn on the balance/ scale: Press e  To change configurations: See the chapter entitled Configuring the Balance/ Scale  To load factory-set configurations: See Configuring the Balance/ Scale, parameter 9  1 $ To tare the balance/ scale: Press t Additional Functions  To turn off the balance/ scale: Press e Example Basic weighing Menu code settings: Factory-set codes Step Key (or instruction)Display/ Printout 1. Turn on the balance/ scale e Self-test is performed 2. Place container on balance/ + 52.0 g scale (here: 52 g) 3. Tare the balance/ scale t + 0.0 g 4. Place sample in container on +150.2 g balance/ scale (here: 150.2 g)

Always calibrate/ adjust the balance/ scale after setting it up in a new location.

Available Features Calibration/ adjustment can only be performed when  there is no load on the balance/ scale,  the balance/ scale is tared,  the internal signal is stable. If these conditions are not met, an error message is displayed. The weight required for calibration/ adjustment is displayed (see Accessories for calibration weights; for model GC503 see Equipment Supplied). On Basiclite balances, calibration/ adjustment can be performed with any of three weight units: g, kg* * , or lb (menu code 1. 4. x) Factory setting: Grams (menu code 1. 4. 1) Example Calibrate the balance/ scale Menu code settings: Factory-set codes Step Key (or instruction)Display/ Printout 1. Turn on the balance/ scale e 2. Tare the balance/ scale t 0.0 g 3. Begin calibration t >2 sec. +1000.0 Calibration weight is displayed without weight unit (here: 1000 g) 4. Place the indicated calibration 1000.0 weight on the balance/ scale After calibration, the calibration +1000.0 g weight is displayed with wt. unit 5. Remove the calibration weight 0.0 g * Calibration technically means to determine the difference between the balance/ scale readout and the actual weight on the pan to determine the accuracy. Adjustment means to bring a balance/ scale into the state of accuracy required for its use. Therefore, calibration, as used in this manual, actually means adjustment. * * = not on models with a readability of 0.1 mg

W ith the Counting program you can determine

the number of parts that each have approximately equal weight. Available Features  Store the current weight value to have it loaded as the preset reference sample quantity next time you initialize the Counting application  The reference sample quantity can be changed in the operating menu: See Configuring the Balance/ Scale  The average piece weight is automatically output via the optional data interface port after initialization, if the menu code for Printout with data ID codes is set  Press v to toggle the display between piece count and weight Factory Settings Reference sample quantity: 10 (menu code 3. 3. 2) Preparation  Configure the Counting application in the operating menu: See Configuring the Balance/ Scale Menu code 2. 1. 4 Counting  Reference sample quantity: Menu code 3. 3. 1 5 pcs Menu code 3. 3. 2 10 pcs Menu code 3. 3. 3 20 pcs Menu code 3. 3. 4 50 pcs Menu code 3. 3. 5 100 pcs See also Configuring the Balance/ Scale

Determine an unknown piece count; weigh the preset reference sample quantity

Settings (changes in the factory settings required for this example): Menu: Application program: Counting (menu code 2. 1. 4) Reference sample quantity: 20 pcs (menu code 3. 3. 3) Step Key (or instruction)Display/ Printout 11. Turn on the balance/ scale e 12. Tare the balance/ scale t 0.0 g 13. Display the reference sample v >2 sec. r ef 20 (briefly) quantity (here: 20 pcs) 14. Place the reference sample + 66.0 g quantity (20 pcs) on the balance/ scale (here: 66 g) 15. Start the application; if the v + 20 pcs print format is set to include data ID codes, the following is printed: wRef + 3.300 g 16. Weigh uncounted parts + 174 pcs (here: 174 pcs) 17. Display weight v + 574.2 g 18. Display quantity v + 174 pcs 19. Unload the balance/ scale 0 pcs 10. Delete the reference value c 11. Repeat the procedure starting from step 6, if desired.

Weighing in Percent

Purpose This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight. Available Features  Store the current weight value to have it loaded as the preset reference percentage next time you initialize the Weighing in Percent application  The reference percentage can be changed in the operating menu: See Configuring the Balance/ Scale  The reference percentage is automatically output via the optional data interface port after initialization, if the menu code for Printout with data ID codes is set  Press v to toggle the display between percentage and weight Factory Settings Reference percentage: 10 (menu code 3. 3. 2) Preparation  Configure the Weighing in Percent application in the operating menu: See Configuring the Balance/ Scale Menu code 2. 1. 5 Weighing in percent  Reference percentage: Menu code 3. 3. 1 5 % Menu code 3. 3. 2 10 % Menu code 3. 3. 3 20 % Menu code 3. 3. 4 50 % Menu code 3. 3. 5 100 % See also Configuring the Balance/ Scale

Determine an unknown percentage; store the weight on the balance/ scale

as a reference percentage Settings (changes in the factory settings required for this example): Menu: Application program: Weighing in percent (menu code 2. 1. 5) Menu: Reference percentage 100 % (menu code 3. 3. 5) Step Key (or instruction)Display/ Printout 11. Turn on the balance/ scale e 12. Tare the balance/ scale t 0.0 g 13. Display the reference percentage v > 2 sec. r ef 100 14. Place the reference weight +222.50 g for 100% on the balance/ scale (here: 222.5 g) 15. Start application; if the print v +100.00 % format is set to include data ID codes, the following is printed: Wxx% + 222.500 g 16. Place an unknown weight +144.94 % on the balance/ scale (here: 322.5 g) 17. Display weight v + 322.5 g 18. Display percentage v +144.94 % 19. Unload the balance/ scale 0.00 % 10. Delete the reference percentage c 11. Repeat the procedure starting from step 6, if desired.

Use this program to determine weights under

unstable ambient conditions. In this program, the balance/ scale calculates the weight as the average value from a defined number of individual weighing operations. These weighing operations are also known as subweighing operations or subweighs. Available Features  The measured result displayed is the arithmetic mean shown in the selected weight unit; a triangle indicates that this is a calculated value  You can set the number of subweighing operations performed in the operating menu: See Configuring the Balance/ Scale  Press v for at least 2 sec. to display the preset number of subweighing operations  Press v to toggle the display between the calculated result and the weight Factory Settings Number of subweighs for averaging: 10 (3. 3. 2) Preparation  Configure the Weigh Averaging application in the operating menu: See Configuring the Balance/ Scale Menu code 2. 1.12 Averaging  Number of subweighs for weigh averaging: 3. 3. 1 5 subweighs 3. 3. 2 10 subweighs 3. 3. 3 20 subweighs 3. 3. 4 50 subweighs 3. 3. 5 100 subweighs See also Configuring the Balance/ Scale

Determine the weight of a sample in extremely unstable ambient conditions

by calculating the average of 10 subweighing operations. Settings (changes in the factory settings required for this example): Menu: Application program: Weigh Averaging (menu code 2. 1.12) Step Key (or instruction)Display/ Printout 1. Turn on the balance/ scale e 2. Tare the balance/ scale t 0.0 g 3. Display the number of subweighs (here: 10) v >2 sec. r ef 10 (briefly) 4. Place sample on the balance/ + 8888 scale (weight readout fluctuates; here: about 275 g) 5. Start measurement v + 8888 10 9 8 ... 1 After 10 subweighs + 275.5 g G If the print format is set to include data ID codes, the following is printed: RES + 275.5 g 6. Unload the balance/ scale + 275.5 g G (stable display) 7. Delete the result c 8. Repeat the procedure starting from step 4, if desired.

Net-Total Formulation/ Second Tare Memory

W ith this application program you can weigh in components for formulation of a mixture. Preparation Configure the Net-Total Formulation/ Second Tare Memory application in the operating menu: See Configuring the Balance/ Scale Menu code 2.1.3 Example Step Key (or instruction)Display/ Printout 1. Turn on the balance/ scale e 2. Place an empty container on + 65.0 g the balance/ scale 3. Tare the balance/ scale t 4. Add the first component + 120,5 g 5. Store the first component weight v 0.0 gNET If the print format is set to include data ID codes, the following is printed: N1 + 120.5 g 6. Add the next component + 70,5 g 7. Store the 2nd component weight v 0.0 gNET 8. Add further components, As described if desired for steps 5 and 6 9. Display total weight c + 191,0 g and fill to desired final weight

Toggle Between Weight Units

W ith this application program you can toggle the display of a weight value back and forth between two weight units. Configure the Toggle Weight Units application in the operating menu: See Configuring the Balance/ Scale, menu code 2.1. 2 Toggle weight units (Factory setting on Gemlite models) Menu code Unit Conversion factor Abbr. on printout 1. 7. 1 3. 1. 1 Taiwanese taels 4) 0.02666666000 o (only selectable on Gemlite scales) 1. 7. 2 o 3. 1. 2 o Grams 1.00000000000 g 1. 7. 3 1) 3. 1. 3 1) Kilograms 0.00100000000 kg 1. 7. 4 2) 3. 1. 4 Carats 5.00000000000 ct 1. 7. 5 3. 1. 5 Pounds 0.00220462260 lb 1. 7. 6 3. 1. 6 Ounces 0.03527396200 oz 1. 7. 7 3. 1. 7 3) Troy ounces 0.03215074700 ozt 1. 7. 8 3. 1. 8 Hong Kong taels 0.02671725000 tlh 1. 7. 9 3. 1. 9 Singapore taels 0.02645544638 tls 1. 7. 10 3. 1. 10 Taiwanese taels 0.02666666000 tlt 1. 7. 11 3. 1. 11 Grains 15.43235835000 GN 1. 7. 12 3. 1. 12 Pennyweights 0.64301493100 dwt 1. 7. 13 3. 1. 13 Milligrams 1000.00000000000 mg 1. 7. 14 3. 1. 14 Parts per pound 1.12876677120 / lb 1. 7. 15 3. 1. 15 Chinese taels 0.02645547175 tlc 1. 7. 16 3. 1. 16 Mommes 0.26670000000 mom 1. 7. 17 3. 1. 17 Austrian carats 5.00000000000 K 1. 7. 18 3. 1. 18 Tola 0.08573333810 tol 1. 7. 19 3. 1. 19 Baht 0.06578947437 bat 1. 7. 20 3. 1. 20 Mesghal 0.21700000000 MS 1. 7. 22 3. 1. 22 lb/ oz  Gemlite scales only 0.03527396200 o  = Factory setting 1) = not for models with a readability of  0.2 mg 2) = Factory setting only for model GC503 3) = Factory setting only for GM models 4) = Readability in increments of 1 digit Function To toggle the display between the 1st and 2nd weight units: Press the v key

Configuring the Balance/ Scale

Setting the Parameters (Menu Codes) You can configure your Basiclite balance or Gemlite scale to meet individual requi- rements by selecting from the parameters available in the menu. Example: Adapt the balance/ scale to unstable ambient conditions: Menu code 1 1 4 Step Key (or instruction)Display 1. Turn off the balance/ scale e 2. Turn the balance/ scale back on; e while all segments are displayed: t briefly 1. $ To navigate within a menu t 2. level; the last menu option is repeatedly ... followed by the first option 9. 1. 3. Select the 2nd menu level p 1. 1. 4. Select the 3rd menu level p 1. 1. 2 o 5. In Menu Level 3: t Select the desired option repeatedly 1. 1. 4 6. Confirm new setting; the o indicates the currently set p option for 2 sec. 1. 1. 4 o $ Select the next menu level (here: move from the 3rd to the 1st level) p 1. $ Set other menu codes, if desired p , t 7. Store parameter settings t and exit operating menu for 2 sec. or $ Exit operating menu without storing changes e > Restart the application 0.0 g

Balance/ Scale Operating Menu (Overview)

 Factory setting User setting Menu 1. Balance/ 1.1. Adapt filter 1.1.1 Minimum vibration scale functions 1.1.2  Normal vibration 1.1.3 Strong vibration 1.1.4 Extreme vibration 1.3. Stability range 1.3.1 1/ 4 digit 1.3.2 1/ 2 digit 1.3.3 1 digit 1.3.4  2 digits 1.3.5 4 digits 1.4. Weight unit for 1.4.1  Grams calibration weight* 1.4.2 Kilograms* * 1.4.3 Pounds 1.6. Auto zero 1.6.1  On 1.6.2 Off 1.7. Weight unit 1 See Toggle between Weight Units 2. Application 2.1. Program selection see the desired application program programs description 3. Application 3.1. Weight unit 2 see Toggle between Weight Units parameters 3.3. Reference qty or % see the desired application program description 5. through 7. applies only if an interface is installed; see the corresponding instructions 8. Extra functions 8.1. Menu 8.1.1  Parameter settings: alterable 8.1.2 Parameter settings: read only 8.2. External switch function applies only if an interface is installed; see the corresponding instructions 8.3. Power-on mode 8.3.1 Off/ on (battery shuts off automatically after 3 min) 8.3.2  Standby/ on 9. Reset menu 9. Factory settings 9. 1 Reset 9. 2  Do not reset * = only for BL models * * = not for models with a readability of 0.1 mg Menu level 1 Menu level 2 Menu level 3 Factory setting Menu level 4

Error codes are shown on the main display for approx. 2 seconds, after which the program automati-

cally returns to the weighing mode. Display Cause Solution No segments appear on No AC power is available Check the AC power supply the display The AC adapter is not Plug in the AC adapter plugged in Battery is dead Replace the battery Recharge the battery using an external charger h The load exceeds the Unload the balance/ scale balance/ scale capacity l The weighing pan is not in place Place the weighing pan on the balance/ scale Something is touching Move the object that is the weighing pan touching the weighing pan e 01 Display capacity exceeded: Decrease the weight on Value to be output cannot be the balance/ scale shown on the display e 02 Calibration parameter Calibrate only when zero requirement not met; e.g.: is displayed  balance/ scale not zeroed Press t to tare the balance/ scale  balance/ scale is loaded Unload the balance/ scale e 09 W hen gross value  zero, no tare Tare the balance/ scale e 10 The t key is blocked when Press c to clear the there is data in the second tare tare memory and release the memory (net-total)  only 1 tare tare key function can be used at a time e 11 Value input is not allowed for Press t second tare memory e 22 Weight is too light or there is Increase the reference quantity no sample on the balance/ scale or sample amount e 30 Interface port for printer Contact your local Sartorius output is blocked Service Center Max. weighing capacity is less The balance/ scale was Place the weighing pan on the than indicated under turned on without the weighing balance/ scale and press e Specifications pan in place to turn the balance/ scale back on The weight readout The balance/ scale has not Calibrate/ adjust the balance/ is obviously wrong been calibrated/ adjusted scale The balance/ scale was not Tare before weighing tared before weighing If any other errors occur, please contact your local Sartorius Service Center.

Care and Maintenance

Service Regular servicing by a Sartorius technician will extend the service life of your balance/ scale and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from1 month to 2 years. The frequency of the maintenance intervals depends on the user's operating conditions and the tolerance limits. Repairs Repair work must be performed by trained service technicians. Any attempt by untrained persons to perform repairs may lead to hazards for the user. Cleaning ! Disconnect the balance/ scale from the AC adapter and unplug any interface cables that are connected to the balance/ scale ! Make sure that no liquid enters the balance/ scale housing ! Do not use any aggressive cleaning agents (solvents or similar agents)  Clean the balance/ scale using a piece of cloth which has been wet with a mild detergent (soap)  After cleaning, wipe down the balance/ scale with a soft, dry cloth Removing and Cleaning the Weighing Pan: Lift up and remove the weighing pan together with the pan support by gripping them from under the shield ring. Make sure that you do not damage the weighing system in doing so.

If there is any indication that safe operation of the

balance/ scale with the AC adapter is no longer warranted:  Turn off the power and disconnect the equipment from AC power immediately > Lock the equipment in a secure place to ensure that it cannot be used for the time being Safe operation of the balance/ scale with the AC adapter is no longer ensured when:  there is visible damage to the AC adapter  the AC adapter no longer functions properly  The AC adapter has been stored for a relatively long period under unfavorable conditions In this case, notify your nearest Sartorius Service Center or the International Technical Support Unit based in Goettingen, Germany. Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius and who  have access to the required maintenance manuals  have attended the relevant service training courses Instructions for Recycling the Packaging To ensure adequate protection for safe shipment, your balance/ scale has been packaged to the extent necessary using environmentally friendly materials. After successful installation of the balance/ scale, you should return this packaging for recycling because it is a valuable source of secondary raw material. For information on recycling options, including recycling of old weighing equipment, contact your municipal waste disposal center or local recycling depot.

Basiclite Series and Gemlite Series

Model BL210S BL120S BL60S GC503 GM1205 Weighing capacity g 210 120 60 505 ct/ 101 1200 Readability mg 0.1 0.1 0.1 0.001 ct/ 0.2 50 Tare range (subtractive) g 210 120 60 505 ct/ 101 1200 Repeatability mg 0.1 0.1 0.1 0.001 ct/ 0.2 50 Linearity mg 0.2 0.2 0.2 0.002 ct/ 0.4 100 Operating temperature range +10 +30C 0 +40C (50F86F) (32F104F) Sensitivity drift within +10 +30C / K 2106 2106 2106 2106 2105 Response time (average) s 3 3 3 3 2 Adaptation to ambient conditions By selection of 1 of 4 optimized filter levels Display update (depends on the filter level selected) s 0.10.4 External calibration weight g 200 (E2) 100 (E2) 50 (E2) 100 (F1) 1000 (F2) (of at least accuracy class ) lb 0.4 (E2) 0.2 (E2) 0.1 (E2)   Net weight, approx. kg/ lb 3.0/ 6.6 3.0/ 6.6 3.0/ 6.6 2.8/ 6.2 1.4/ 3.1 Pan size mm 80  80  80  80  174 x 143 inches 3.3  3.3  3.3  3.3  6.9 x 5.6 Weighing chamber height mm 200 200 200 133  inches 7.9 7.9 7.9 5.2  Dimensions (WxDxH) mm 200x251x299 200x251x233 189x250x70 inches 7.9x9.9x11.8 7.9x9.9x9.2 7.4x9.8x2.8 AC power source/ power requirements AC adapter, 230 V or 115 V, +15% 20% Frequency 4860 Hz Power requirements, direct current V 10 to 20 Power consumption (average) W 1 1 1 1 0.75 Approx. hours of operation with:  9-volt battery, approx. h     11  fully charged rechargeable battery h     2.5 Hours of operation with the YRB07Z rechargeable battery pack h 20 20 20 20 25

Basiclite Series and Gemlite Series

Model BL150S BL1500S, BL610, BL310, GM212 BL150, BL6100, GM1502 GM612 GM312 GM152 GM6101 Weighing capacity g 150 1500 610 310 210 150 6100 Readability g 0.001 0.01 0.01 0.01 0.01 0.01 0.1 Tare range (subtractive) g 150 1500 610 310 210 150 6100 Repeatability g 0.0015 0.015 0.01 0.01 0.01 0.01 0.1 Linearity g 0.003 0.03 0.02 0.02 0.02 0.02 0.2 Operating temperature range 0 +40C (263 313 K, 32F 104F) Sensitivity drift within  +10 +30C / K 3.3106 3.3106 0.5105 1105 1105 2105 0.5105 Response time (average)s 2.5 2.5 2 2 2 1.5 2 Adaptation to ambient conditions By selection of 1 of 4 optimized filter levels Display update (depends on the filter level selected) s 0.20.8 External calibration weight g 100 (F1) 1000 (F1) 500 (F2) 100 (F2)100 (F2) 100 (M1) 5000 (F2) (of at least accuracy class ) lb* 0.2 (F1) 2 (F1) 1 (F2) 0.2 (F2) 0.2 (F2) 0.2 (M1) 10 (F2) Net weight, approx. kg / lb 1.6/ 3.5 1.4/ 3.1 1.1/ 2.4 1.1/ 2.4 1.1/ 2.4 1.1/ 2.4 1.4/ 3.1 Pan size mm 100  174x143 116  116  116  116  174x143 inches3.9  6.9x5.6 4.6  4.6  4.6  4.6  6.9x5.6 AC power source/ power requirements AC adapter, 230 V or 115 V, +15%  20% Frequency 4860 Hz Power requirements, direct current V 10 to 20 Power consumption (average) W 0.75 Approx. hours of operation with:  9-volt battery, approx. h   11 11 11 11 11  fully charged rechargeable battery h   2.5 2.5 2.5 2.5 2.5 Hours of operation with the YRB07Z rechargeable battery pack h 25 * = only for BL models

Basiclite und Gemlite Serie

Model BL3100, BL1500 BL600, BL12 BL6 BL3 GM3101 GM601 Weighing capacity g 3100 1500 610 12000 6000 3000 Readability g 0.1 0.1 0.1 1 1 1 Tare range (subtractive) g 3100 1500 610 12 6 3 Repeatability g 0.1 0.1 0.1 1 1 1 Linearity g 0.2 0.2 0.2 2 2 2 Operating temperature range 0 +40C (263 313 K, 32F 104F) Sensitivity drift within +10 +30C / K 1105 2105 5105 2.5105 5105 10 105 Response time (average) s 2 1.5 1.5 1.5 1.5 1.5 Adaptation to ambient conditions By selection of 1 of 4 optimized filter levels Display update (depends on the filter level selected) s 0.20.8 External calibration weight kg 1 (F2) 1 (M1) 0.5 (M1) 5 (M1) 5 (M1) 1 (M1) (of at least accuracy class ) lb* 2 (F2) 2 (M1) 1 (M1) 10 (M1) 10 (M1) 2 (M1) Net weight, approx. kg/ lb 1.4/ 3.1 Pan size mm 174x143 (6.9x5.6 inches) AC power source/ power requirements AC adapter, 230 V or 115 V, +15%  20% Frequency 4860 Hz Power requirements, direct current V 10 to 20 Power consumption (average) W 0.75 Approx. hours of operation with:  9-volt battery, approx. h 11  fully charged rechargeable battery h 2.5 Hours of operation with the YRB07Z rechargeable battery pack h 25 * = only for BL models

Interface port, installation kit

for models with a readability 1mg YDO01BL for models BL210S, BL120S, BL60S, GC503 YDO02BL Data printer YDP04 Data printer YDP03-0CE with date/ time, statistics evaluation and transaction counter functions and LCD (data interface required) Paper (5 rolls) 6906937 Remote display (data interface required) reflective YRD12Z for overhead projectors, transmissive YRD13Z External rechargeable battery packYRB08Z with external battery charger (hours of operation: 20 or 40. depending on balance/ scale model) SartoWedge data transfer softwareYSW01 for on-line storage of weighing data Interface cable 7357312 for connecting a PC; 25-pin Universal remote control switch: (data interface required) Foot switch with T-connector YFS01 Hand switch with T-connector YHS01 T-connector YTC01 for connecting 2 peripheral devices (data interface required) Carrying case for models with a readability 1mg YDB01BL for models BL210S, BL120S, BL60S YDB02BL Product Order No. Dust cover, for use during weighing  for models with a rectangular weighing pan 6960BC02 for models with a round weighing pan 6960BC03 Attaching the dust cover to models with a glass draft shield: Remove adhesive strip from balance/ scale housing Place dust cover on balance/ scale Stick adhesive strip on dust cover Gem trays 300 ml, weight: 86 g, stainless steel 6407 1000 ml, wt.: 240 g, stainless steel 641211 300 ml, wt.: 22 g, aluminum 69641304 110 ml, 90  mm, aluminum YWP02G 270 ml, wt.: 62 g, 137  mm stainless steel YWP03G Calibration weights for BL210S (200 g; E2) YCW5228 for BL120S, BL150S, GC503* (100 g; E2) YCW5128 for BL60S (50 g; E2) YCW4528 for the BL150, BL310, GM512, GM212, GM312 (100 g; F2) YCW5148 for the BL610, BL600, GM612, GM601, (500 g; F2) YCW5548 for the BL1500S, GM1502 (1 kg; F1) YCW6138 for the BL1500, BL3100, BL3, GM3101, GM1205 (1 kg; F2) YCW6148 for the BL6100, BL6, BL12, GM6101 (5 kg; F1) YCW6538 or alternative YSS653-00 * = F1 100-g weight supplied with the GC503 scale

The C marking affixed to the equipment indicates that the equipment

meets the requirements of the following Directive(s): Council Directive 89/ 336/ EEC Electromagnetic compatibility (EMC) Applicable European Standards: Limitation of emissions: EN 50081-1 Residential, commercial and light industry EN 50081-2 Industrial environment Defined immunity to interference: EN 50082-1 Residential, commercial and light industry EN 50082-2 Industrial environment Important Note: The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equipment not supplied by Sartorius and must check and, if necessary, correct these modifications and connections. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the Standards listed above for defined immunity to interference). Council Directive 73/ 23/ EEC Electrical equipment designed for use within certain voltage limits Applicable European Standards: EN 60950 Safety of information technology equipment including electrical business equipment EN 61010 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements If you use electrical equipment in installations and under ambient conditions requiring higher safety standards, you must comply with the provisions as specified in the applicable regulations for installation in your country.

37070 Goettingen, Germany

p Weender Landstrasse 94108, 37075 Goettingen, Germany t (+49/ 551) 308-0, f (+49/ 551) 308-32 89 Internet: http:// www.sartorius.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. Status: July 2000, Sartorius AG, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine  W 199-A00  KT Publication No.: W BL6005-e00072