Sharp AE-X2M14LR Service Manual
Text of the manual
Parts marked with "
" are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
CHAPTER 1. SPECIFICATIONS
[1]
SPECIFICATION ...........................................1-1
[2]
EXTERNAL DIMENSION ..............................1-2
[3]
CAPACITY TABLE.........................................1-3
[4]
ELECTRICAL PARTS....................................1-3
[5]
WIRING DIAGRAMS.....................................1-4
CHAPTER 2. EXPLANATION OF CIRCUIT AND OP-
ERATION
[1]
BLOCK DIAGARM ........................................2-1
[2]
FUNCTIONS .................................................2-2
[3]
ACTIVE FILTER CIRCUIT.............................2-4
[4]
EXPLANATION OF IPM DRIVE CIRCUIT
........2-6
CHAPTER 3. FUNCTION AND OPERATION OF PRO-
TECTIVE PROCEDURES
[1]
PROTECTIVE FUNCTIONS AND OPERA-
TIONS............................................................ 3-1
[2]
TROUBLESHOOTING GUIDE ...................... 3-2
CHAPTER 4. REFRIGERATION CYCLE
[1]
REFRIGERATION SYCLE............................. 4-1
[2]
REFRIGERANT PIPE INSTALLATION
WORKS ......................................................... 4-2
CHAPTER 5. DISASSEMBLING PROCEDURE
[1]
OUTDOOR UNIT ........................................... 5-1
Parts Guide
TopPage
CONTENTS
MULITI SPLIT TYPE
ROOM AIR CONDITIONERS
(OUTDOOR UNIT)
AE-X2M14LR
MODEL
In the interests of user-safety (Required by safety regulations in some
countries) the set should be restored to its original condition and only
parts identical to those specified should be used.
1 – 1
AEX2M14LR
Service Manual
CHAPTER 1. SPECIFICATIONS
[1] SPECIFICATION
NOTE: The condition of star “✩“marked item are ‘ISO5151’:
*: Representative connection
ITEMS
INDOOR UNIT
AY-XPM7FR/9FR/12FR
OUTDOOR UNIT
AE-X2M14LR
Cooling capacity
kW
2-INDOOR OPERATION
7K & 7K
3.8(1.8 – 4.3)*
Heating capacity
kW
2-INDOOR OPERATION
7K & 7K
4.4 (1.9 – 5.4)*
Moisture removal
Liters/h
1.6
✩ Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
230V
Rated current
Cool
A
4.1 (1.6 – 5.3)*
Heat
A
4.4 (1.7 – 5.9)*
Rated input
Cool
W
900(350– 1160)*
Heat
W
950 (370 – 1300)*
Power factor
Cool
%
95
Heat
%
94
Compressor
Type
Hermetically sealed DC twin rotary
Model
DA130A1F-28F
Oil charge
Ester oil VG74
Refrigerant system
Evaporator
Silt Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Name of refrigerant
R410A
Refrigerant volume
1680g
Noise level (at cooling)
dB(A)
High/Med/Low
7FR: 37/34/28
45
9FR: 39/36/28
12FR: 40/37/29
Fan system
Drive
Direct drive
Air flow quantity (at cooling)
.
m3/min.
High/Med/Low
7FR: 8.0/7.4/5.4
33
9FR: 8.6/7.9/5.6
12FR: 10.2/8.6/6.1
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8”, 1/4”
Maximum length (per unit)
m
25
Maximum length (total)
m
40
Maximum charge-less length
m
25
Maximum height difference
m
10
Additional Charge (per m)
g
15
Drain joint
mm
Connected part O.D.16
Others
Safety device
Compressor: Thermistor
Fan motors: Thermal fuse (indoor unit).
Thermal protector (Out door unit)
Fuse, Micro computer control
Air filters
Anti-mold polypropylene net of injection type (Washable)
Net dimensions
Width
mm
790
950 (890+60)
Height
mm
278
645
Depth
mm
198
323 (290+33)
Net weight
kg
10
51
1 – 2
[2] EXTERNAL DIMENSION
117
320
24
24
52
284
645
621
210
151
940
323
890
290
50
5
570
170
52
179
320
645
527
890
950
60
1 – 3
[3] CAPACITY TABLE
COOLING CAPACITY TABLE
HEATING CAPACITY TABLE
[4] ELECTRICAL PARTS
Recommended Combination
Outdoor Units
Indoor Units
AY-XPM7/9/12FR, GS-XPM9/12, GS-XPM7/9/12FR
AE-X2M14LR
12
7
9
9
9
7
7
7
Operating
Status
Combination of
Indoor Units
Cooling Capacity (kW)
Running Current (A)
Power Consumption (W)
A
B
A
B
RATING (Min. - Max.)
RATING (Min. - Max.)
RATING (Min. - Max.)
2-Room
12
09
2.2
1.6
3.8 (1.8 - 4.3)
4.1 (1.6 - 5.3)
900 (350 - 1160)
12
07
2.4
1.4
3.8 (1.8 - 4.3)
4.1 (1.6 - 5.3)
900 (350 - 1160)
09
09
1.9
1.9
3.8 (1.8 - 4.3)
4.1 (1.6 - 5.3)
900 (350 - 1160)
09
07
2.1
1.7
3.8 (1.8 - 4.3)
4.1 (1.6 - 5.3)
900 (350 - 1160)
07
07
1.9
1.9
3.8 (1.8 - 4.3)
4.1 (1.6 - 5.3)
900 (350 - 1160)
1-Room
12
OFF
3.4
OFF
3.4 (1.4 - 4.0)
4.2 (1.5 - 6.0)
900 (320 - 1320)
09
OFF
2.6
OFF
2.6 (1.4 - 3.3)
3.0 (1.5 - 4.2)
660 (320 - 920)
07
OFF
2.0
OFF
2.0 (1.4 - 2.7)
2.3 (1.5 - 3.2)
510 (320 - 700)
Operating
Status
Combination of
Indoor Units
Heating Capacity (kW)
Running Current (A)
Power Consumption (W)
A
B
A
B
RATING (Min. - Max.)
RATING (Min. - Max.)
RATING (Min. - Max.)
2-Room
12
09
2.5
1.9
4.4 (1.9 - 5.4)
6.6 (1.7 - 5.9)
950 (370 - 1300)
12
07
2.8
1.6
4.4 (1.9 - 5.4)
6.6 (1.7 - 5.9)
950 (370 - 1300)
09
09
2.2
2.2
4.4 (1.9 - 5.4)
6.6 (1.7 - 5.9)
950 (370 - 1300)
09
07
2.5
1.9
4.4 (1.9 - 5.4)
6.6 (1.7 - 5.9)
950 (370 - 1300)
07
07
2.2
2.2
4.4 (1.9 - 5.4)
6.6 (1.7 - 5.9)
950 (370 - 1300)
1-Room
12
OFF
3.9
OFF
3.9 (1.2 - 4.6)
5.2 (1.5 - 7.2)
1140 (320 - 1570)
09
OFF
3.0
OFF
3.0 (1.2 - 4.2)
3.8 (1.5 - 6.4)
830 (330 - 1400)
07
OFF
2.4
OFF
2.4 (1.2 - 3.3)
3.1 (1.5 - 4.6)
680 (320 - 1010)
Compressor
DA130A1F-28F
Hermetically sealed DC twin rotary
Outdoor fan motor
MLB051
Fuse 1, 101
—
QFS-GA065JBZZ(20A,250V)
Fuse 6
—
QFS-GA064JBZZ(1A,250V)
Fuse 3, 4
—
QFS-GA062JBZZ(3.15A,250V)
Fuse 5
—
QFS-GA063JBZZ(2A,250V)
1 – 4
[5] WIRING DIAGRAMS
IPM P.W.B.
from ELECTROLYTIC CAPACITOR C10(+)
from ELECTROLYTIC
CAPACITOR C10(-)
from COMPRESSOR TERMINAL
W "ORANGE"
from COMPRESSOR TERMINAL
V "WHITE"
from COMPRESSOR TERMINAL
U "RED"
from CONTROL PWB CN14
from CONTROL PWB BCN1