Shuttle Brewers & Airpot/Shuttle Brewers

Troubleshooting (cont.) Brewing Problems Problem Possible Causes Service Check Remedy Brew volume too large or too small • Sprayhead clogged. • Brew valves clogged with lime deposits. • Water supply pressure or flow rate not adequate. • Visually check for clogging of holes in brewhead. • Visually inspect brew valve at hose connections. • Check to see that fill valve cycles on and off frequently during brew cycle when all brew heads are used simultaneously. Check to ensure that water supply line is 3/8” and pressure is between 30 an ...

Shuttle Brewers & Airpot/Shuttle Brewers

Page 9 Programming (All values are preset at the factory and may vary brewer to brewer.) Settings Routine Programming For All Brewer Settings and Large Portion (refer to Table 1) 11. Press and hold both “up” and “down” arrows for 5 seconds. 12. All three “brew” lights will flash. 13. Press “Large Brew” button. Only “Large” ready light illuminates during remaining steps. 14. Display will indicate either “d F” or “d C” (Fahrenheit or Celsius). Default is “d F”. 15. Press “up” or “down” arrow to change from one to an ...

Shuttle Brewers & Airpot/Shuttle Brewers

Troubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy Tank does not refill • No electrical power to equipment • No water supplied to equipment • No power to control board • No power to control board and transformer not powered. • No power to control board and transformer powered. • Check for proper voltage at terminal block. Check circuit breaker on supply circuit. • Disconnect water supply line and ensure that water is provided to unit. Check to see that any and all valves in water line are open. � ...

Shuttle Brewers & Airpot/Shuttle Brewers

VS-1.5S VS-S 3 1 8 5 2 9 6 7 4 5 1 4 6 2 3 7 8 ITEM NO. Title PART NUMBER VS-1.5S/QTY. 1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Vacuum Shuttle VS-1.5 1 4 Stand Base A548-158 1 5 Tray Top A517-018 1 6 Self-Tapping Screw .5" A539-217 4 7 Rubber Foot A548-161 4 8 Plastic Insert A548-162 3 9 Self-Tapping Scres .75" A539-218 3 ITEM NO. Title PART NUMBER VS-S/QTY. 1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Stand Base A548-158 1 4 Tray Top A517-018 1 5 Stand, Top Plate A517-019 1 6 NUT M4 W Nylon Insert A540-237 4 7 Self-Tappi ...

Shuttle Brewers & Airpot/Shuttle Brewers

Installation WARNING ELECTRIC SHOCK HAZARD! Installation of this appliance should be performed by qualified service personnel only. Improper installation could result in electrocution. Set-Up/Position 1) Remove the brewer from the packing material and attach its legs. 2) Position the brewer on a strong, stable table or counter. Check the level front to back and side to side. Adjust the legs to the correct level. IMPORTANT: THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE FOR ENSURING THAT ELECTRIC AND WATER CONNECTIONS MEET THE REQUIREMENTS ...

Shuttle Brewers & Airpot/Shuttle Brewers

Programming For All Brewer Settings and Large Portion (cont.) Table 1 TANK TEMP (170-205F) BYPASS TO LOW-TEMP/NO-BREW NO-BREW BYPASS RATIO ) L OR L L BYPASS % (OFF, 1-33) LOW-TEMP/ (OFF, 1 - 6) PULSE ON TIME (0:05-0:60) # OF PULSES OR OR PULSE OFF TIME (0:05-0:60) BYPASS RATIO (0.20-1.25) PULSE BREW BREW TIME TEMP SCALE ADJUST DISPLAY READING ADVANCE L L L L L BREW TIME (0:01-6:00) L L L L L L (MAX CHANGE DEPENDING ON RATIO (BYPASS FLOW RATE DIV. BY SPRAY HEAD FLOW RATE) 1. PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. 2. READY LIGHTS WILL FLAS ...

Shuttle Brewers & Airpot/Shuttle Brewers

Wiring Diagram - PB-430E 230V, PBVSA-430E230V, PBIC-430E 230V (Single or Three Phase Models) ...

Shuttle PB-330 user guide recommended for: Matic Elevation H1, 8558, Eclipse Hv16, XLE-MD-DF-AD-HS-BP, Series A.

⚠️ Download Safety

The Dispenser Operation and instruction manual (36 pages) is completely safe to download (last scan date: 28/02/2026).

Related PDF Instructions for Shuttle PB-330:

Dispenser Equipment: Frequently Requested

Have some Questions about Shuttle PB-330 Device?

Get valuable and actionable advices from other Shuttle PB-330 device users. Describe your problem or question, regarding the using of PB-330, in as much detail as possible, and other users will be able to answer you.