ACTpro mifare 1050 Pin and Proximity Reader (Entry)

ACTpro mifare 1040 Proximity Reader (Exit) Controller SENSE CLOCK DATA +5V 0V RED GREEN CARD/PROX READER 2 3 1 5 6 4 8 9 7 0 White Green Blue Red Black Brown Yellow Orange No Connect No Connect SENSE CLOCK / D1 DATA / D0 12V 0V RED GREEN BUZZER A B Wiring for Reader The standard wiring colours for ACTpro proximity and pin readers is shown above. 125V AC 30V DC +12V 0V Data Clock Sense Red Grn B uzz Connection block view of ACTpro mifare 1040/1050. Unit C1, S outh City Business Center, Tallaght, Dublin 24, Ireland. Telephone: +353 1 466 2570. Telefax: 353 1 452 0427. E-mail: sales@ accesscontrol.ie Web: www.accesscontrol.ie Wiring for Entry/Exit Readers ACTpro mifare product range 1040/1050 ACT mifare ACT mifare A B +12v 0V General Wiring information READER MUST BE POWERED FROM 12vDC ACTpro mifare 1040 Sector No: 00005 Test Powering on the reader requires 12V and 0V to be Connected. Data read from a card is presented on the Data/Clock pins. If configured for wiegand output the D0 signal is available on Data and D1 is available on Clock. The Sense signal is driven low when the reader outputs Clock and Data information, this can be used to distinguish between Entry and Exit (see below) The Internal buzzer is activated by applying 0V to the Buzz. The buzzer activates 4 seconds after the 0V is applied and sounds continuously till the 0V is removed. The Red/Green led is activated by applying 0V to the respective Red/Grn input. READER MUST BE POWERED FROM 12vDC To make a reader an exit reader leave the Sense line unconnected. To make a reader an entry reader ensure the Sense line is connected. Rev 1.3 27/04/2007 +12v 0V PAGE 1

Unit C1, South City Business Center, Tallaght, Dublin 24, Ireland.

Telephone: +353 1 466 2570. Telefax: 353 1 452 0427. E-mail: [email protected] Web: www.accesscontrol.ie ACTpro mifare product range 1040/1050 OUTPUT DATA FORMAT Default Output Format is Clock and Data (also know as Magnetic Stripe Track/2 or ABA). Using this default format the data is encoded as 10 BCD digits . Clock and Data Wiegand The reader can be configure to output the data in wiegand format instead of clock and data. Connecting the Sense line to OV before powering on the reader will switch the unit to wiegand output mode. The reader will output 37 bit wiegand. SECTOR/SERIAL OPERATION The default sector reader operation of ACTpro mifare readers is to read the batch numbers that are encoded into Sector 1 from the mifare Cards and Fobs issued by ACT. However the readers can be programmed to read any specified sector data, this allows the readers to be installed on sites that are already using mifare cards. See next page for more details on reader re-programming. Sector Reader Serial Reader When in Serial Reader mode the card serial number of any mifare card that is presented is read. The reader may be placed in serial mode linking pins 2 and 3 together and reapplying power to the board, link should be left in place. The ACTpro mifare reader can also provide the Serial number Byte Reversed, in this case remove the jumper and re-apply power to the reader. To select Wiegand Output connect SENSE and 0V together. Power must be reapplied for change to take effect, connection should be left in plac Sector/Serial Operation Jumper. Reader Configuration The ACTpro mifare 1040/1050 can operate as a sector or serial reader, selectable via a jumper. The default position of the jumper is for sector operation (jumper on pins 1 and 2). 1 Sector Operation: Jumper Pins 1 and 2 Serial Operation: Jumper Pins 2 and 3 Serial Operation (Byte Reversed): Remove Jumper PAGE 2 Clock Data 12Vdc Sense Buzz B A Grn Red 0V 3 2

Unit C1, S outh City Business Center, Tallaght, Dublin 24, Ireland.

Telephone: +353 1 466 2570. Telefax: 353 1 452 0427. E-mail: sales@ accesscontrol.ie Web: www.accesscontrol.ie ACTpro mifare product range 1040/1050 Reader Reprogramming The ACTpro mifare 1040/1050 readers ship from the factory pre-configured to read the mifare Cards and Fobs supplied by ACT. On sites with an existing installation of mifare cards, it will probably be necessary to reprogram the ACTpro mifare 1040/1050 so that the data on the existing cards maybe read. The configuration required by ACTpro mifare 1040/1050 to read the existing mifare cards is given to the ACTpro mifare 1040/1050 via a programming card. The programming card contains the complete information about how to access the data on the existing mifare cards. Programming cards may be supplied by ACT or they can be generated on site if ACTWinPro/ProLite is installed and an ACTpro mifare usb reader is used. To reprogram an ACTpro mifare reader the programming card must be presented to the ACTpro mifare reader after power up and while the Led is Red. The ACTpro mifare will acknowledge the re-programming by playing an ascending note tune. The configuration is held in non-volatile memory and so is held even if the reader is powered down. Readers that have been reprogrammed may be reset to read ACT issued mifare Cards and Fobs with a ACT Default Programming Card. ACTpro mifare readers that have been programmed to read none ACT mifare Cards and Fobs will play a series of ascending notes after being powered up in addition to the standard beep codes, this is to indicate that it no longer reads the mifare Cards and Fobs issued by ACT. Please see the "Application for an ACTpro mifare reader programming card" document for deatils on obtaining a programming card. Page 3 Power On Beep Codes The Output Data Format and the Sector/Serial Operation of the reader can be determined by the beeps generated by the reader after power is applied. The reader will generate two sets of beeps, the first indicating the Output Data Format and the second set of beeps indicates Sector or Serial Operation. The first set of beeps will occur while the Led is Green, the second set of beeps occur half a second later while the Led is Blue. First Beep Set: Double Beep: Sector Reader Single Beep: Serial Reader Triple Beep: Serial Reader (Byte Reverse) Second Beep Set: Double Beep: Clock and Data Output Single Beep: Wiegand 37 bit Output Note: If the reader has been re-programmed (see next page), then a serial of notes is played after the Second Beep Set, this indicates that the readers default programming to read ACT mifare cards has been changed.

Security screw supplied with

the unit. Place the Reader / Keypad onto the surface mount collar and clip down into place.Use the security screw supplied to attach the unit to the surface mount collar. Place the Reader / Keypad onto the surface mount collar and clip down into place.Use the security screw supplied to attach the unit to the surface mount collar. View showing mounting plate before spacers are broken away by installer. The surface mount collar is mounted on the wall using the fixing kit supplied in the box. Mounting plate is attached to the pattress ox using the screws supplied. Ensure the corect spacers have been used to bridge the gap between the mounting plate and the fixing wings of the pattress box to avoid the mounting plate being distorted. Standard pattress box. Spacers break away from main component when required by installer for use. Screws Security screw supplied with the unit. Place the cap onto the unit and push firmly into place. Note: Determine the distance between the patress box and the mounting plate, using the spacers that are labelled 1mm to 4mm. A spacer of the correct length is assembled by stacking the spacers together. Place the cap onto the unit and push firmly into place. View showing spacers stacking Mounting Instructions for Flush Mount Unit Mounting Instructions for Surface Mount Unit PAGE 4