Euro Video EVD-16/400A16HC Installation & Operation Manual

Text of the manual

DIGITAL VIDEO RECORDER

(H.264 – 4/8/16 CHANNEL) Quantum PLUS – Installation and User manual

Installation and Operation

EVD-16/400A16HC 2 www.eurovideo-cctv.com WARNING: To prevent a risk of fire of electric shock, do not expose this product to rain or moisture. • This installation should be made by a qualified service person and should conform to all local codes. • This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Copyright This manual is the intellectual property of Manufacturer and is protected by copyright. All rights are reserved. No part of this document may be reproduced or transmitted for any purpose, by whatever means, be they electronic or mechanical, without the express written permission of Manufacturer. Edition : Aug.2009 � Copyright 2009 Manufacturer Note This Manual was compiled with the greatest of care and all information double checked. At the time of printing the description was complete and correct. Because of the further development of products, the content of the manual might change without prior notice. Manufacturer will not be liable for damage which is directly or indirectly due to errors, incompleteness, or discrepancies the manual and the product described. Trade marks All names used in this manual for hardware and software are very probably

Installation and Operation

EVD-16/400A16HC 3 www.eurovideo-cctv.com registered trade marks and must be treated as such.

Installation and Operation

EVD-16/400A16HC 4 www.eurovideo-cctv.com CE INFORMATION The product must be installed according to the currently valid installation regulations for EMC to guarantee the designed use and to prevent EMC problems. The device supplied with this manual is according to the EC, EMC Directive, 89/336/EEC & LVD 73/23/EEC Standard used for showing compliance with the essential requirements of the device: EN 55022 EN 61000-3-2 EN 61000-3-3 EN 50130-4 EN 55024 LVD: EN60950-1 ELECTRICAL SAFETY Explanation of electrical safety symbols

Installation and Operation

EVD-16/400A16HC 5 www.eurovideo-cctv.com Contents Description Page No Safety Precautions 8 Contents of packaging 9 Features 10 Front Panel 11 Rear Panel connections 14 System Connection diagram 16 Remote Control 17 OSD Description ( On Screen Display ) 18 Menu Tree 19 Default Password 21 Main Menu 22 Menu Navigation 22 DISPLAY 23 Camera Setting 23 Camera Covert 23 Spot Setting 24 OSD on/off 24 Event Clear 25 Apply 25 RECORDING 25 Global 25 Normal 26 Alarm Recording 26 Motion Recording 27 Schedule Recording 28

Installation and Operation

EVD-16/400A16HC 6 www.eurovideo-cctv.com Audio Event 29 Time Lapse 30 Recording Priority 30 SYSTEM 31 Basic 35 Disk Format 35 Password Change 36 Client Account 36 Program Update 37 Sensor 38 PTZ Setup PTZ Controller NETWORK 39 DDNS 39 IP SET 40 NTP 41 LIVE 42 EVENT NOTIFICATION 43 E-Mail Registration 43 SMTP Mode 44 Email Out 45 Beep/Alarm Out 46 SEARCHING VIDEO FOOTAGE 47 Date / Time Search 47 EVENT 47 Calendar Search 48 DOWNLOADING EVIDENCE 51 LOG 53 CLIENT SOFTWARE / IE Viewer 54 Minimum PC Specification 54 Explanation of Screen buttons 55

Installation and Operation

EVD-16/400A16HC 7 www.eurovideo-cctv.com Live monitoring 56 REMOTE SEARCH 59 Remote Setup 66 Local Search 81 Local Setup 84 Pan, Tilt, Zoom, Focus 85 Firmware Upgrade 86 Quit(Stop Client Program/IE Viewer) 86 APPENDIX 1 – Alarm Sensor Installation 87 APPENDIX 2 _ Installing Grypes WEB Client 90 APPENDIX 3 – DYNAMIC IP (Supporting DDNS) 94 APPENDIX 4 – Setup for DVR port / Web server port using IP Sharing router ( Port Forwarding) 97 APPENDIX 5 – Making a partition on an External USB hard drive 99 APPENDIX 6 – System Specification 106

Installation and Operation

EVD-16/400A16HC 8 www.eurovideo-cctv.com SAFETY PRECAUTIONS CAUTION BEFORE USE Please read this manual before installing or using this DVR. Please keep this manual in a safe place, to allow for future reference For the safety and proper use, The DVR is marked with various symbols. Please read these to prevent injury of financial loss. INSTALLATION SITE Ensure installation position is level, secure and adequately ventilated. Avoid installing close to sources of humidity or water.

Installation and Operation

EVD-16/400A16HC 9 www.eurovideo-cctv.com CONTENTS OF PACKAGING Power Cable Digital Video Recorder System Please read this manual before using User Manual Remote Controller Battery

Installation and Operation

EVD-16/400A16HC 10 www.eurovideo-cctv.com FEATURES ● Convenience - User-friendly GUI( Graphic Based User Interface) - Easy-to-use menu structure - Easy-to-use recorded data search (Time, Date, Motion, Alarm) - Easy-to control via Front Panel, IR remote control and USB 2.0 MOUSE . ● Stability - Auto restart after power interruption - DB structure offers data stabilization and best storage utilization ● Expandability -Various remote multi DVR’s can be controlled by Web browser (PC Client System) ● Technology -Embedded LINUX OS -Totally maximum recording rate 480/400 fps -High-resolution & high-quality MPEG-4 algorithm -Using Water marking & scrambling technologies, -Strong protection recorded data -MPEG-4 : 1 ~ 2 Kbytes per image with resolution 360x240 ● Functionality - Variable recording function (normal, alarm, motion, schedule, audio, Time Lapse,) - Full channel real-time monitoring - Live monitoring, recording, playback, backup, remote access simultaneously - Multi channel playback - Variable events notification to e-mail, buzzer or PC Client system - PTZ & PTZ Controller is available by RS485

Installation and Operation

EVD-16/400A16HC 11 www.eurovideo-cctv.com FRONT PANEL 1) LED - REC: Recording status (When recording is on, the red light is blinking) - POWER: System Power On/Off (When power is on, the green light is lit up) (2) USB 2.0 PORT - USB2.0 connector, for downloading to USB pens / drives (plus upgrading firmware ) (3) POWER BUTTON - System Power On/Off (4) NUMERIC & CHARACTER - Input for numeric’s & letters (5) MENU - Displays the menu on the screen (6) SEARCH - Entering search mode

Installation and Operation

EVD-16/400A16HC 12 www.eurovideo-cctv.com (7) PLAY ( ) - Playback of the recorded data - When in play mode press again to enter fast forward mode. (8) REWIND ( )� - Playback on the reverse (9) PAUSE ( ▌▌) - To freeze picture on playback mode and live mode. (10) STOP / EJECT ( █ ) - To stop playback and go back to live mode. - To eject DVD-RW (11) REC (●) - It starts & stop manual recording of relevant camera in a full screen live mode. (12) ARROW KEY - Moves the cursor while in menu mode (13) SELECT - Menu selection (14) Camera Selection - Camera Channel section (15) Screen Split - Selection of multi screen functions (16) PTZ - To control P/T/Z, press this button to browse virtual key on screen.

Installation and Operation

EVD-16/400A16HC 13 www.eurovideo-cctv.com REAR PANEL CONNECTIONS (1) VIDEO IN (BNC) - 16/8/4 Camera input (1.0v p-p, 75Ω) (2) VIDEO OUT - 16/8/4 LOOP / SPOT / Composite / S-VIDEO / VGA (3) LINE AUDIO INPUT - 16/8/4 Audio input through line (4) AUDIO OUTPUT - 1 Audio output (5) RS232 - 1 Serial Communication (6) Network Port (RJ-45) - Available to monitor live screen and recorded data on the HDD through Internet or LAN

Installation and Operation

EVD-16/400A16HC 14 www.eurovideo-cctv.com (7) USB 2.0 -USB 2.0 connector (8) ALARM / SENSOR - ALARM / 16/8/4 SENSOR INPUT / 1 OUTPUT PORT (9) CAMERA / KEYBOARD CONTROLLER - 1 Serial Communication for Pan / Tilt Camera - 1 Serial Communication for P/T/Z Control Keyboard (10) AC POWER - AC 110~240 V (Free Voltage) ATTENTION When the video format is changed, the system should be re-booted The video format should be selected before booting

Installation and Operation

EVD-16/400A16HC 16 www.eurovideo-cctv.com REMOTE CONTROL 1. Power: Power ON/OFF 2. Rec: Start & Stop Recording 3.�~�: Key for figure and character 4. P/T/Z: Entering PTZ menu directly 5. OSD: Operating OSD ON/OFF 6. SEQ: Key for SEQ operation 7. LOG: Direct access Log list 8. INFO: Direct access system Info. 9. ID: Reserved. 10. MUTE: Audio Mute 11. AUDIO: Available audio switching when user select this key 12. MENU: Entering system menu 13. SEARCH: Entering search 14. ARROW & SPLIT: Key moving left, right, up and down. Also, Screen split display shows 15. VOL”+,-“ : Up, down volume 16. CH “+,-“ : Up, down channel(s) 17. ▶(▶) : Play(or fast forward) 18. � (� ) : Reverse play 19 II : Pause 20. █: Stopping playback 21. Cam: Changing PTZ icon 22. P/T: Pan &Tilt 23. Z/F: Zoom/ & Focus 24. DIS: Channel Division

Installation and Operation

EVD-16/400A16HC 17 www.eurovideo-cctv.com OSD DESCRIPTION : Status Bar is shown HDD capacity, Event, Network connection, Time, etc using by icons. -HDD Capacity : 1.7GB is used out of 298.0GB -Event(i.e. Power Fail ) : Power Fail, Video loss, etc will be shown when it is occurred. -Network connection : It is shown that admin or user is connected. -Date/Time *Others : -Backup -Mute -USB Stick: It shows PTZ controlling, as CH2 is Speed Dome input. It is able using by arrow keys. Record Standby: It is shown when recording is not activated. PTZ icon

Installation and Operation

EVD-16/400A16HC 18 www.eurovideo-cctv.com M MEENNUU TTRREEEE Menu tree Display Recording System Camera Setting Camera Covert Camera Name Spot Setting Event Clear Basic Disk Format Password Change Client Account Program Update Main Menu Video Type Time/DST Set System ID Date Format Sensor Live Resolution User Name New Password Confirm PW OSD Setting Apply Apply Time Lapse Priority Apply Frame rate Recording Sound On/Off Setup Motion Setup Schedule Auto Delete Mode Language Global Normal Alarm Motion Schedule Audio Event PTZ Setup PTZ Controller Post Duration Quality Pre Resolution Watermark HDD Overwrite Pre FPS Pre Duration

Installation and Operation

EVD-16/400A16HC 19 www.eurovideo-cctv.com Network Set DDNS LIVE Search E-Mail Registration SMTP Mode Beep Out Event DDNS User ID User Password Domain Dynamic IP IP Gate Way Net Mask DNS Server DSL ID DSL PW DVR Port Web Port Apply Alarm Out Apply Search Menu Date/Time Event Calendar Backup Log Record Operation Client Event All Power IP SET NTP Power Loss Motion Video Loss Alarm E-Mail Out

Installation and Operation

EVD-16/400A16HC 20 www.eurovideo-cctv.com DEFAULT PASSWORDS Front Panel Password is required if you need to enter the menus; down power; stop recording or changing an IP setting. A prompt will be displayed asking for password. The default Password is: 00000000 (8 zeros) Client Program / IE When using the supplied browser software the following password will be required. User ID is “admin” (not case sensitive). Password is “00000000” i.e. 8x Zero’s (Admin ID cannot be changed, as this is the full administrator ID)

Installation and Operation

EVD-16/400A16HC 22 www.eurovideo-cctv.com MAIN MENU NOTE Before usage, be sure to setup the unit properly. To enter the set-up menu press the Menu button and enter the password (default password is 00000000 – 8 zeros). The following screen will be displayed. Menu Navigation To step back through the menus press MENU button -Front Panel or IR remote control All menus are navigated around using the left / Right / Up / Down and the Select button. -MOUSE(USB 2.0) Via USB2.0 Mouse, please press right button to launch all menu option.

Installation and Operation

EVD-16/400A16HC 23 www.eurovideo-cctv.com DISPLAY Camera Setting : Bright, Saturation, Contrast, Hue, default The picture displayed from each camera can be individually adjusted to balance the multi screen view. Please use UP(�) / DOWN(�) or Numeric buttons on the front panel or left button on the Mouse to move to next menu. To move to the submenu, use the SELECT button. It will be applied instantly without “Apply”. Camera Covert Cameras can be hidden from the viewer in live or play back mode. Turn the camera on or off using the left and right buttons around the SELECT button. Camera Name Each camera can be titled using the Alphanumeric buttons on the front panel or Mouse. It will be available upto 32 characters, if the monitor couldn’t show it in 1 line, it will be shown as _... For example, ‘FIRST MEETING ROOM’ -> ‘FIRST MEETIN…’

Installation and Operation

EVD-16/400A16HC 24 www.eurovideo-cctv.com Spot Setting <9 Channel Divisions> <16 Channel Divisions> Spot output is used when user would like to see event channel instantly. For example, if you want to see ‘Motion’ event channel, please set as ‘Motion’ in the ‘Mode’ section then, select duration. Spot Mode is available from ‘Single/Quad/9Channel/16Channel/Alarm/Motion/Audio. OSD Setting OSD Setting: Selecting whether the time and date etc is shown on the screen or not. New setting value will be applied instantly without pressing “Apply”.

Installation and Operation

EVD-16/400A16HC 25 www.eurovideo-cctv.com Event Clear This is used to erase the list, in the memory, of previous events such as alarm activations. APPLY : In order to save any modified setting value, please press “SEL” key in the “APPLY” section. NOTE In every first sub menu_ Display, Recording, System, Network, Event has “APPLY” feature in the above. If any setting value is changed, “Apply” is required to save the new value. User can simply save new value pressing “Apply” once in one sub menu. Camera Setting & OSD Setting doesn’t need to be pressed “ Apply” RECORDING In our system, all recorded data can be saved in the format of watermark or scrambling when user select “watermark : On” So, After downloading the saved data you want to check , user can confirm whether it is changed by someone using our PC software we provided. Also, individual recording resolution is available to set in each mode and channel. Global Within this section: 1. Watermarking should be set to on, this allows the supplied software to verify the downloaded information to ensure it has not been tampered with or changed. 2. Repeat recording can be set to continually overwrite or stop when the drives are full. 3. Pre Recording resolution can be set to 4CIF – 720 X 576/ 720 X 480 (giving 120/100fps recording ) or 2CIF -720 X 288 / 720 X 240 (240/200fps) or CIF - 360 X 288 / 360 X 240 (480/400fps). 4. Pre FPS/Pre Duration/Post Duration are recommended to set active to get data just before event occurs. Post Duration are selectable. -Pre FPS : 0/1/3/5 fps -Pre Duration & Post Duration : 5/30/60/90/120/150/180/210/240 sec. 5. Quality can be set among High/Middle/Low. These settings are applied to all

Installation and Operation

EVD-16/400A16HC 26 www.eurovideo-cctv.com channels. Normal It executes the continuous recording according to the designated set-up value. The above shows available frame rate each channel. In 360x240 modes, 30 fps is available each channel (totally 480fps), 720x 240 is 15 fps each (Totally 240fps), 720x480 is 7.5 fps each(Totally 120fps). Individual frame rate control is available and selecting audio on/off individually as well. Figures can be changed pushing the “↑,↓” button. Alarm

Installation and Operation

EVD-16/400A16HC 27 www.eurovideo-cctv.com It executes the recording when sensor is taken. There are 16 Alarm inputs on the rear of the DVR, these can be used to initiate the Alarm record mode. How to set is same as Normal. Motion Motion on any channel can trigger recording of that camera User can select Recording Frame and Audio On/Off, same as Normal and Alarm recording. Moreover, Motion Sensitivity and Motion Region is available. Motion Sensitivity It consists of High, Mid, Low. Motion Region The following will be displayed when user selects the menu. 1 2 3 4 5 6 7 8 9 10

Installation and Operation

EVD-16/400A16HC 28 www.eurovideo-cctv.com The detection area is divided 11x8 cells. Default is all-cells activating mode. 1~10 cells(white color background) is disabled area. “SEL” button is required for selecting some area. NOTE When you record the camera image with the motion recording mode, the data file will be saved depending on the motion sensitivity. So, higher caution is required to apply the sensitivity to the actual recording. Schedule recording It executes the recording as per the programmed time table. The above shows available frame rate each channel. In 360x288 mode, 25 fps is available each channel (totally 400fps), 720x 288 is 12.5 fps each (totally 200fps), and 720x576 is 6.25fps (totally 100fps) . Individual frame rate control is available as above image. Setting values will be changed pushing the “↑,↓” button

Installation and Operation

EVD-16/400A16HC 29 www.eurovideo-cctv.com “SEL” button is used for selecting relevant time and day. Arrow Key will be used for movement. Audio Event 16 Audio Inputs and 1 Output are available. User can select Fps, Audio On/Off, Recording

Installation and Operation

EVD-16/400A16HC 30 www.eurovideo-cctv.com Quality in the Audio Event menu. NOTE Audio output channel is able to select by clicking USB Mouse to each channel or by IR remote controller. Time Lapse It helps user to set FPS automatically if user select Recording & Audio On/Off in each channel and days to record. So, if the user set Recording & Audio On/Off in the channel and set the days, it will show the assigned FPS. NOTE: If recording is in Standby mode, the icon is as follows. Priority The RECORD PRIORITY allows the mixing of the various record methods to customize the individual site requirements. Recording Quality Three levels of compression: High, Mid, Low. Save and Exit

Installation and Operation

EVD-16/400A16HC 31 www.eurovideo-cctv.com All the values set-up will be stored and screen will step back to higher level menu..

Installation and Operation

EVD-16/400A16HC 32 www.eurovideo-cctv.com SYSTEM The SYSTEM menu is where all the non-recording based settings are configured Basic User can set Language, Auto Delete Mode, Date Format, Time/DST Set, Video Type, System ID, Live Resolution in the Basic. Also, Initialization and checking Information is available. Language The default is English. Italian, French, Hungarian, Slovak, German, Russian, Chinese, Dutch, Spanish, Portuguese, Japanese and Polish are available. Auto Delete Mode Auto Delete Mode will remain recorded data only for specified days and the rest days will be erased automatically. User can select from 00days to 99days. Date Format The default is dd-mm-yyyy. The date format is available among mm-dd-yyyy / dd-mm-yyyy / yyyy-mm-dd.

Installation and Operation

EVD-16/400A16HC 33 www.eurovideo-cctv.com Time / DST Set NOTE PLAYBACK FOLLOWING TIME CHANGE The DVR uses the time and date to index video on the hard disk drive so you can find it later. Changing the time can cause the DVR to work improperly when you try to play back video. If you set the hour ahead, this is not a problem. But, if you set the hour back, there will be more than one recording at the same time. Such as during the October Daylight Saving Time changeover, if you try to search for video between 1 am and 2 am, the recorder may not operate properly because there will be two hours of recorded video during this time period. To view video during this overlapping time period, you must start playback before 1 am, then recorder will play both hours between 1 am and 2 a.m. You cannot do a backward search through the overlapping time. But, you can do forward search. User can change Time for DVR and able to set DST in this menu. Time Set It is available as left image, after changing the year, date & time “Apply” is required to be applied. The default is DST OFF

Installation and Operation

EVD-16/400A16HC 34 www.eurovideo-cctv.com -Virtual Keyboard (Mouse user only) DST Set It will be available either by Day or Date. When user press ‘User Define’, available country will be shown. Then, select Start & End Time and Offset as well. At last, press ‘Apply’ to save the figures. Video Type Video Type is able to set by software, it can be simply done in this menu without rebooting or initialization. The default is PAL.

Installation and Operation

EVD-16/400A16HC 35 www.eurovideo-cctv.com SYSTEM ID The remote control can be used to control up to 16 DVRs, the ID number on each can be set to a unique address so that the remote will only control one at a time if they are in close proximity. The default is 11. Use the right arrow to change the ID number. To select a unit on the remote control press the ID button, followed by the number, followed by the ID button again. The LED will flash slowly. Initialization All the menu value will be returned to the factory default. To carry out this function the system recording will have to be turned off. ID Button

Installation and Operation

EVD-16/400A16HC 36 www.eurovideo-cctv.com Information The Information Screen shows the hard disk size, current firmware revisions, IP address and MAC address Disk Format Formatting of the drive is used when new drives are installed or you need to wipe all information on the disk.

Installation and Operation

EVD-16/400A16HC 37 www.eurovideo-cctv.com Password Change The password can be change from the factory default to a more secure one, a note of any new password should be taken and stored in a secure place. CLIENT ACCOUNT When viewing over a network up to 6 connections can be made simultaneously, one can have complete control e.g. view live and playback, and the other 5 can view live only. ADD NEW ACCOUNT Network users can be set up under this menu; a name and password need to be entered for each account. Once setup they will appear in the User1~5.

Installation and Operation

EVD-16/400A16HC 39 www.eurovideo-cctv.com Program Update Always turn off: Recording, Playback and Network access while upgrading the unit The latest firmware version can be upgraded through USB 2.0 Port using Memory Stick or CD/DVD Media. When memory stick connects USB port, will be shown on the status bar of the screen. Enter “menu”-> “System Set”-> “Program Update”. If the system recognizes the new firmware then, “New program found” will be displayed on the screen. Next press the “SELECT” button. Processing percentage will be displayed. NOTE. 1. If the system doesn’t recognize the new firmware, “New program not found” will be displayed. 2. USB compatibility has been tested successfully with: Lexar Jumpdrive 128/256MB, Sandisk Mini Cruzer & Cruzer Micro 2GB, KINGSTONE 2GB, A-DATA 2GB, SANDISK 1GB, SANDISK 512MB, MARUZEN 1GB 3. For system stability, please off 1) recording 2) playback 3) network connection during upgrading. 4. After updating program, reboot should be required. The simplest way is press POWER button once as shown on the message.

Installation and Operation

EVD-16/400A16HC 41 www.eurovideo-cctv.com SENSOR The 16 alarm inputs and 1 output on the rear of the DVR can be configured to be normally open or closed. Sensor Input is selectable N.C, N.O, None.

Installation and Operation

EVD-16/400A16HC 42 www.eurovideo-cctv.com NETWORK (If you connect network, this icon will be shown) To enter Network set menu, system ask password (Default is 00000000). With in the Network menu the DDNS (Dynamic Domain Named Server), IP addresses, NTP and Live can be set. DDNS What is DDNS? DDNS is a service that maps Internet domain names to IP addresses. DDNS serves a similar purpose to DNS: DDNS allows anyone hosting a Web or FTP server to advertise a public name to prospective users. Unlike DNS that only works with static IP addresses, DDNS works with dynamic IP addresses, such as those assigned by an ISP or other DHCP server. What this means is that the DVR does not need a Static IP address to be available for viewing remotely over the World Wide Web. Please refer to Appendixes 4 on how to set up the DDNS service.

Installation and Operation

EVD-16/400A16HC 43 www.eurovideo-cctv.com DDNS ON DDNS OFF IP SET When a fixed IP address is being used, the Use Dynamic IP should be set to No The IP Address, Gateway and Subnet Mask need to be set, these will generally be given by the Network Manager. DSL refers to all types of Digital Subscriber Line such as ADSL and SDSL

Installation and Operation

EVD-16/400A16HC 44 www.eurovideo-cctv.com NTP It supports keep matching local time from internet to the DVR. The default is NTP OFF.

Installation and Operation

EVD-16/400A16HC 45 www.eurovideo-cctv.com LIVE It allows individual Live resolution regardless of System Recording and gives Quality option as well to have better network streaming. Ie) In order to get the fastest Network Live transmission, please choose ‘Resolution’ : CIF and ‘Quality’ : Low.

Installation and Operation

EVD-16/400A16HC 46 www.eurovideo-cctv.com Event This section is used to inform the user as to an event occurring, this can simply be by the sounding of a buzzer or by sending an E-mail to a predefined address. E-Mail Registration Within this section up to 3 users can be set-up to receive an email on the occurrence of an event such as Video Loss / Alarm / Motion or Power Loss. An E-mail will only be sent if the DVR is sitting on a network with access to the Internet, e.g. through a router. The e-mail addresses are set via the alphanumeric buttons on the front panel.

Installation and Operation

EVD-16/400A16HC 47 www.eurovideo-cctv.com For SENDER MAIL ID and SENDER DOMAIN, this is best explained by an example, if the following is input: SENDER MAIL ID: DVR1 SENDER DOMAIN: GOOGLE.COM Then the receiver will receive a mail from [email protected] Note: This is not a valid e-mail address for replies. SEND TEST MAIL sends a test E-mail to the addresses so allowing the installer to verify if the setup is correct. SMTP Mode It allows email can be run in LAN as well. The default is SMTP Mode “OFF”. In order to activate SMTP Mode, choose SMTP Mode either IP or Domain first. Then, put ID, Password, IP address, and port. Finally press “SMTP Status Check” to see whether it works. Please see the images as follows.

Installation and Operation

EVD-16/400A16HC 48 www.eurovideo-cctv.com E-mail Out As well as e-mail on event activations the DVR can be set to send a report of what has happened daily / weekly or immediately. This sends a mail containing the log report.

Installation and Operation

EVD-16/400A16HC 49 www.eurovideo-cctv.com Beep / Alarm Out When an event (e.g. Video loss, Alarm, Motion or power loss) occurs the following actions can be triggered: E-mail – As described in previous section Beep – The buzzer can be sounded. Alarm out – The relay contact on the rear of the unit can be closed.

Installation and Operation

EVD-16/400A16HC 51 www.eurovideo-cctv.com SEARCHING VIDEO FOOTAGE To access the search option, press the SEARCH button on the front panel. The following screen will be displayed. Date / Time Search If you select date/time search, the following will be shown. EVENT: Allows the user to select between ALL, MOTION or ALARMS. Select required option by pressing the right arrow. ALL – The search is for a block of video within the times defined MOTION – The search is for any motion events within the times defined ALARMS – The search is for any alarm activation within the times defined

Installation and Operation

EVD-16/400A16HC 52 www.eurovideo-cctv.com HDD: Allows searching on either the INTERNAL hard drive or an EXTERNAL device plugged onto the USB port. Select required option by pressing the right arrow. DATE: Allows the user to select the start time required for the search. Set the date by highlighting the DATE option , then press SEL the select button, use the alphanumeric buttons to select the time and date required. Once the selection criteria are entered move to play by pressing the down button and press SEL to play the video. Calendar Search Following screen shows when “Calendar search” is selected. The Calendar search gives a graphical representation of when video is recorded on the hard drive. The year and month can be selected, this month is shown as a calendar on the screen, any day which contains recorded video will be indicated by a highlighted number in white. Move to the desired day by using the up / down / left / right buttons, Select the day by

Installation and Operation

EVD-16/400A16HC 54 www.eurovideo-cctv.com The following screen will be displayed. The hours which has the recorded data are displayed as the color bar of each event and if the hours which you want to play are selected, the following sub-menu will be displayed The following screen will be displayed The minutes which have recorded data will be displayed as the color bar of each event and if the minutes which user wants to play is selected, the playback is operated. Video will start playing from the selected time.

Installation and Operation

EVD-16/400A16HC 55 www.eurovideo-cctv.com * Preview function Before user searches recorded data on the calendar menu, user can preview the recorded data behind window on the screen after pressing “PTZ” button in minute of Calendar Search. In addition, user can choose each minute to preview.

Installation and Operation

EVD-16/400A16HC 56 www.eurovideo-cctv.com DOWN LOADING EVIDENCE(Backup) Once the required video has been found, it may be necessary to down load it for evidential purposes. This can be done either onto the internal CD/DVD-R writer or via the USB port on the front of the DVR. To do this press the SEARCH button and using the down button move to BACK UP, once highlighted press SEL, the following screen will be displayed. Backup Device This allows selection between the internal CD /DVD-R writer and the FLASH option via the USB port, when highlighted use the right arrow to toggle between the options. Device Format Format for CD/DVD-R is not needed. When using CD/DVD-R or USB, format should be done first. Type EXCLUSIVE is available for File format.

Installation and Operation

EVD-16/400A16HC 57 www.eurovideo-cctv.com If evidence is downloaded as an Exclusive file, the DVR will download bespoke player software on to the CD / DVD or USB device along with the evidence. This means that no special software is required, by the reviewing PC. This format is secure and watermarked. LOG Log list is available for downloading in this menu. If only want to download LOG LIST, check the box and do not select any channel for downloading. From/ To You can set up the start and stop time which is required to be backed up to the internal CD/DVD-R or USD device. Highlight this option, then press SEL, then use the alphanumeric buttons to set the time and date. Repeat for the end time. Channel For EXCLUSIVE file format, the number of channels to be down loaded can be selected. Anything from a single channel to all 16 can be selected. Calculated Backup size Once the time and date and file format have been entered, it is necessary to confirm that the size of file created will not exceed the size of memory available on the disk or USB device. Move to Calculated Back Up Size and press SEL. The unit will then calculate storage space required for download file. This will be displayed in the required space section. AS long as the Required space size is smaller than the Free/ total space, then move to Transfer. Transfer When Transfer is highlighted press SEL, the downloading will start. Percentage done during downloading will be shown. * USB compatibility: the following have been tested Lexar JumpDrive 128/256MB SanDisk Mini Cruzer 128MB

Installation and Operation

EVD-16/400A16HC 58 www.eurovideo-cctv.com SanDisk Cruzer Micro 256MB, 512GB, 1GB KINGSTONE 8GB A-DATA 2GB MARUZEN 1GB DVD/RW Plextor PX-716UFL Lite-On CD/RW (LTR-52327SX) LOG The log file contains information on the following: Power : Power on, Power off, Power fail Reocrd : Rec fail, Rec start, Rec stop, Rec error, Rec full Operation : Play start, Play stop, HDD format, Menu set Client : R_Login, R_Logout, R_Logfail, R_Play, R_Transfer, R_Rec on, R_Rec off, R_Upgrade Event : Alarm, Motion, Audio, Videoloss, Email_fail A total of 2500 events can be recorded the oldest being overwritten when a new one occurs, the can be viewed all together or individual types as a list.

Installation and Operation

EVD-16/400A16HC 59 www.eurovideo-cctv.com Client Program / IE Minimum PC specification (4, 8/16CH) > CPU : Core 2 Duo 1.8GHz, > Graphic Memory : 256MB (Please upgrade Graphic Card to latest software) Installing software When you put ‘Network installation CD’ into your PC, it will auto run and lead you through an installation wizard. Follow the instructions. Once the software is loaded it will automatically run. Connection When User click the button of ‘Connection’, , of Network installation program, the IP SET window will be appeared to connect to a DVR.

Installation and Operation

EVD-16/400A16HC 60 www.eurovideo-cctv.com LOG IN The following window will appear. To connect to the GDVR, types in the units IP address, DVR Port and ID & Password. Then, click “OK”, which starts the live monitoring. Explanation of Screen Buttons

Installation and Operation

EVD-16/400A16HC 61 www.eurovideo-cctv.com Live Monitoring The software is best viewed on the monitor resolution, 1024 x 768. Multiscreen (1, 4, 6, 7, 8, 9, 10, 13, 16) : Multiscreen division can be done during both live and playback. As seen in picture, 1,4,6,7, 8,9,10,13,16 division are available. 1) Single 2) Multi

Installation and Operation

EVD-16/400A16HC 62 www.eurovideo-cctv.com Full Screen on/ off The small pop-up box is shown when user change to Full screen or point below parts on the screen, and it will be disappeared after 4 seconds. OSD on/off :

Installation and Operation

EVD-16/400A16HC 63 www.eurovideo-cctv.com (SMART)ARRANGE ON/OFF : When Channel direction is mixed on the screen, it makes the camera channel in order. Image Save / Load

Installation and Operation

EVD-16/400A16HC 64 www.eurovideo-cctv.com SAVE : This is for saving format either JPEG or BMP or TIF. There is no change on the main screen when user press “Save” button. LOAD : When user click “Load”, there are lists of saved images. If user selects one of the lists, there will be shown the image with data information (Status-Live/Playback, IP address, CH No.) Playback (Step Backward, Backward, Playback, Pause, Recording, Stop, Step Forward) Audio (Mute, Volume, Select Audio, Microphone) ※ Select Audio : Select Audio from the channels, it toggles in order. ※ Microphone : It is used for transmitting sound to System through microphone. Quit (Stop Client program) Remote search Search (Date/Time/Event/Calender), Backup(Remote Backup), Log(Remote Log) are available. SEARCH This Remote Search is able to play back video on the PC direct from the hard disk storage on the unit. There are 3 options for as follows. 1) Date/Time 2) Event 3) Calendar - Remote search – Date/Time - Remote search – Event

Installation and Operation

EVD-16/400A16HC 65 www.eurovideo-cctv.com When user click “Play” button, this window disappears and Remote Playback will be started. If user clicks one of the lists, “Play” button will be activated. Then click “Play” for Remote Playback. - Remote search – Calendar If user click one of the date in blue (recorded data), user can see the details as follow picture. There are 2 options for Remote Playback. 1) Drag the Red line to the color bar(I.e. Blue : Normal Recording) 2) Click the point which user want to playback on the blue bar then the red line will be dragged to the point. Then click the “Play” button for Remote Playback. Or, click “Prev” to go back to previous stage.

Installation and Operation

EVD-16/400A16HC 67 www.eurovideo-cctv.com User can simply include/exclude channel dependent on own query. It is available for Search, Backup and Log as well. BACK-UP - Remote backup – Date/Time - Remote backup – Event

Installation and Operation

EVD-16/400A16HC 68 www.eurovideo-cctv.com Select Start Date&Time and End Date&Time as well through the light grey bar for backup. Then, click “Calculate” to check the data size. At last, when the data size is shown beside the “Calculate” bow, please click “Backup” button to make backup data. If user select one of the lists, then “Calculate” button will be activated. Then, press “Calculate” to check the data size and press “Backup” finally. - Remote backup – Calendar If user click one of the date in blue (recorded data and able to make backup file), user can see the details as follow picture. There are 2 options for Set Start backup time. 1) Drag the Red line to the color bar(I.e. Blue : Normal Recording) 2) Select specific time on “Start”, then the Red line will move to the selected time. Please, click “Next” button to set “End Backup SET” as follows.

Installation and Operation

EVD-16/400A16HC 69 www.eurovideo-cctv.com The backup procedure is same as Date/Time & Event backup as previous page. * “Prev” to go back to previous stage *The downloaded data is saved in as follows root. C:\Realtime

Installation and Operation

EVD-16/400A16HC 70 www.eurovideo-cctv.com Remote Log User can play the data for Record part log or Log list printing is also available. User can see the “log list” as “ALL” or relevant log only by choosing it’s sub-menu. ※ Sub Menu of Remote Log Power : Power on, Power off, Power fail Reocrd : Rec fail, Rec start, Rec stop, Rec error, Rec full Operation : Play start, Play stop, HDD format, Menu set Client : R_Login, R_Logout, R_Logfail, R_Play, R_Transfer, R_Rec on, R_Rec off, R_Upgrade Event : Alarm, Motion, Audio, Videoloss, Email_fail

Installation and Operation

EVD-16/400A16HC 71 www.eurovideo-cctv.com Info - “System Info” of the Remote Log - “Status Info” of the Remote Log User can see Mac address / System version information. It is shown status of both HDD disk and recording mode by channel.

Installation and Operation

EVD-16/400A16HC 72 www.eurovideo-cctv.com Remote Setup : Checking settings menu (Same as DVR) 1) Display – Camera Setting – Camera Covert

Installation and Operation

EVD-16/400A16HC 73 www.eurovideo-cctv.com Camera Covert is only applied for System Live and User login in ‘Realtime’. - Camera Name Upto 32 Characters are available for Camera Name. - Spot Setting Multi Channel Spot

Installation and Operation

EVD-16/400A16HC 74 www.eurovideo-cctv.com 1) Please set “Mode” first then click “OK” 2) Select Duration using the white bar, user can select/unselect all simultaneously. Event Spot OSD On/Off

Installation and Operation

EVD-16/400A16HC 75 www.eurovideo-cctv.com Recording Global Normal User can set Normal Recording Resolution, Recording Rate and Audio On/Off. -Resolution

Installation and Operation

EVD-16/400A16HC 76 www.eurovideo-cctv.com -Rate -Audio Alarm Alarm setting is same as Normal(Page67) Motion

Installation and Operation

EVD-16/400A16HC 77 www.eurovideo-cctv.com -Resolution -Rate -Audio -Sensitivity -Region

Installation and Operation

EVD-16/400A16HC 78 www.eurovideo-cctv.com User can set Recording Resolution, Recording Rate, Audio, Sensitivity and Region in each channel. The motion area will be displayed when user click the “Region” button. The detection area is divided 11x8 cells and default is all-cells activation mode. The transparent cells are disabled area but, it can be changed able area after clicking on it. Schedule -Resolution -Rate -Audio - Set Schedule

Installation and Operation

EVD-16/400A16HC 79 www.eurovideo-cctv.com Audio Event Please refer previous page to see how to set.

Installation and Operation

EVD-16/400A16HC 80 www.eurovideo-cctv.com Time Lapse -Resolution -Video -Audio -Days Priority

Installation and Operation

EVD-16/400A16HC 82 www.eurovideo-cctv.com Client Account Auto Delete Mode

Installation and Operation

EVD-16/400A16HC 85 www.eurovideo-cctv.com DST Setup -OFF(Default) -USER Define

Installation and Operation

EVD-16/400A16HC 87 www.eurovideo-cctv.com NTP Setup -NTP OFF(Default) -NTP ON

Installation and Operation

EVD-16/400A16HC 88 www.eurovideo-cctv.com EVENT Email Registration Email Out

Installation and Operation

EVD-16/400A16HC 89 www.eurovideo-cctv.com Beep Out Alarm Out

Installation and Operation

EVD-16/400A16HC 90 www.eurovideo-cctv.com Local Search It is available to play downloaded data in PC. Search Date/Time

Installation and Operation

EVD-16/400A16HC 94 www.eurovideo-cctv.com Opacity Audio Buffer PAN& TILT

Installation and Operation

EVD-16/400A16HC 95 www.eurovideo-cctv.com ZOOM&FOCUS Firmware Upgrade User can select Firmware Upgrade menu, if new version exits in C:/Realtime/Upgrade fold, ‘New program found!’ and if not ‘New program not found!’ message will be displayed. User can proceed upgrading after pressing OK button and select each firmware to upgrade it to the system.

Installation and Operation

EVD-16/400A16HC 96 www.eurovideo-cctv.com User can see the display ‘Firmware upgrade success!’ after upgrading it successfully. User have to press OK button to reboot the DVR since the firmware will be applied completely to the system after rebooting it. Quit (Stop Client program) APPENDIX 1 ALARM SENSOR INSTALLATION 1. Components 1) External Sensor: 1 2) DVR System: 1 2. Inner Circuit for Sensor Input The inner circuit of Quantum DVR is as follows,

Installation and Operation

EVD-16/400A16HC 97 www.eurovideo-cctv.com � PC817 : Photo Coupler � The Specification of PC817 � Absolute Maximum Ratings Parameter Symbol Rating Unit Input Forward current IF 50 mA *1Peak forward current I FM 1 A Reverse voltage V R 6 V Power dissipation P 70 mW Output Collector-emitter voltage V CEO 35 V

Installation and Operation

EVD-16/400A16HC 98 www.eurovideo-cctv.com Emitter-collector voltage V ECO 6 V Collector current IC 50 mA Collector power dissipation P C 150 mW Total power dissipation P tot 200 mW *2Isolation voltage V iso 5 000 V rms Operating temperature T opr -30 to + 100 °C Storage temperature T stg -55 to + 125 °C *3Soldering temperature T sol 260 °C *1 Pulse width<=100�s, Duty ratio : 0.001 *2 40 to 60% RH, AC for 1 minute *3 For 10 seconds � Electro-optical Characteristics Parameter Symbol Conditions MIN. TYP. MAX. Unit Input Forward voltage V F IF = 20mA - 1.2 1.4 V Peak forward voltage V FM IFM = 0.5A - - 3.0 V Reverse current IR V R =4V - - 10 µ A Terminal capacitance Ct V = 0, f = 1kHz - 30 250 pF Output Collector dark current ICEO V CE = 20V - - 10 -7 A Transfer charac- teristics *4Current transfer ratio CTR IF = 5mA, V CE = 5V 50 - 600 % Collector-emitter saturation voltage V CE( sat) IF = 20mA, I C = 1mA - 0.1 0.2 V Isolation resistance R ISO DC500V, 40 to 60% RH 5 x 1010 1011 - Ω Floating capacitance Cf V = 0, f = 1MHz - 0.6 1.0 pF Cut-off frequency fc V CE = 5V, I C = 2mA, R L = 100 W, -3dB - 80 - kHz Response time Rise time t r V CE = 2V, I C = 2mA, R L = 100 Ω - 4 18 µ s Fall time tf - 3 18 µ s

Installation and Operation

EVD-16/400A16HC 99 www.eurovideo-cctv.com 1. SENSOR Install Processing � Please refer the below block diagram. PC817 3.3k Or 10k N.C SENSOR 12V DC 2.2k AC Outlet Point ?? V DC SENSOR IN DVR GND

Installation and Operation

EVD-16/400A16HC 100 www.eurovideo-cctv.com APPENDIX 2 INSTALLING REALTIME WEB CLIENT ON WINDOW XP/2000 & WINDOW VISTA SERVICE PACK 2. 1) Security Setup > Window XP / 2000 > Window Vista Tools-> Internet Options-> Security -> Select “Customer Level” Select “ Allow script-initiated windows Without Size or position constraints”-> Enable. Tools-> Internet Options-> Security -> Unselect square box -> Select “Customer Level”

Other DVR Manuals