HP Integrity rx4640 Operation Manual
Read Online
Read the HP Integrity rx4640 Operation Manual online using the built-in PDF viewer.
Text of the manual
hp Integrity rx4640
Operations Guide
Regulatory Model Number: RSVLA-0201
Version 1.0
Manufacturing Part Number: rx4640_op
April 2004
U.S.A.
© Copyright 2003-2004 Hewlett-Packard Development Company, L.P..
Copyright Notices. © Copyright 2003-2004 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products
and services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
Adobe and Acrobat are trademarks of Adobe Systems Incorporated. HP-UX Release 10.20 and later and
HP-UX Release 11.00 and later (in both 32 and 64-bit configurations) on all HP 9000 computers are Open
Group UNIX 95 branded products. Intel and Itanium are trademarks or registered trademarks of Intel
Corporation or its subsidiaries in the United States and other countries. Linux is a registered trademark of
Linus Torvalds. UNIX is a registered trademark of The Open Group. Windows is a registered trademark of
Microsoft Corporation.
Printed in the U.S.A.
Reproduction, adaptation, or translation of this document without prior written permission is prohibited,
except as allowed under the copyright laws.
Related Documents. The HP Server Documentation CD-ROM has been provided with the server. It contains
a documentation set for the server, including localized versions of key documents. Included on the CD-ROM
are the Site Preparation and Operations guides, which contain in-depth troubleshooting and installation
information.
The CD will autorun when you insert it into a Windows workstation, or, point your browser at the index.htm
file located under the Start directory of the CD. All users, including UNIX /Linux, can access a manual set
by viewing the directory manuals. The manuals are in Adobe Acrobat Reader (pdf) format.
IMPORTANT
The latest versions of these documents, and any updates to these documents, are posted under
the appropriate server at http://docs.hp.com.
Where to Get Help. For online access to technical support information, self-solve tools, online assistance,
community forums of IT experts, broad multivendor knowledge base, and monitoring and diagnostic tools, go
to http://www.hp.com/support.
1. About This Document
What’s in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
HP Encourages Your Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Where to Get Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Information to Collect Before You Contact Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2. Controls, Ports, and Indicators
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Switch/Button and Front Control Panel LED Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Additional Controls and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hot-Plug Disk Drive Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
DVD–ROM/DVD-R/DVD-RW Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
QuickFind Diagnostic Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Power Supply Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Management Processor LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Locator LED and Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Gigabit Ethernet Card LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3. External Connectors
Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Universal Serial Bus (USB) Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
VGA Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Management Processor LAN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Additional Ports on Accessory Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4. Utilities
Extensible Firmware Interface (EFI) Boot Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
EFI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
EFI/POSSE Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
baud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
boottest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
cpuconfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
errdump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
lanaddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
monarch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
pdt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
sysmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Specifying SCSI Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Using the SCSI Setup Utility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Management Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Accessing the Management Processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Management Processor Command Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Management Processor Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Reset BMC Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Configure Serial Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Certificate Generate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Console Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Command Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Connect to Service Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Default Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Display FRUID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Disconnect Remote or LAN Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Front Panel Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
MP Firmware Update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Display System ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Inactivity Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Configure LAN Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
LAN Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Return to Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Modem Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Modem Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Configure Paging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Power Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Reset BMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Reset System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Set Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Create Local Session. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Display Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Security Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Firmware Revision Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
System Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Transfer Of Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Tell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
User Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Virtual Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Who . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Exit from MP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Management Processor Help System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Troubleshooting Methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Possible Problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
The system will not power-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
The system will not boot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
The system has intermittent failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
The system LED or Diagnostic LEDs are not on and no error messages appear.. . . . . . . . . . . . . . . . 72
Power goes off on the server and does not come back on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Troubleshooting Using LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Front Control Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
QuickFind Diagnostic Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
I/O Baseboard LED Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Troubleshooting Using Online Support Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Support Tools Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Event Monitoring Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Instant Support Enterprise Edition (ISEE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Troubleshooting Using Offline Support Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Offline Diagnostic Environment (ODE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
e-Diagtools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Management Processor (MP) Event Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Other Event Logs and General Diagnostic Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
6. Specifications
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Dimensions and Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Server Component Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 2-1. Front View with Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 2-2. Accessing the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 2-3. Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 2-4. Hot-Swap Disk Drive LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 2-5. DVD–ROM Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 2-6. QuickFind Diagnostic Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 2-7. I/O Baseboard LEDs, Buttons, and Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2-8. Rack Mount and Pedestal Rear View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 2-9. Power Supply Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 2-10. MP LAN LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 2-11. Core I/O LAN Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 3-1. Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 3-2. USB Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 3-3. Video Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 3-4. Serial Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 3-5. Management Processor Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 3-6. LAN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 3-7. SCSI Port, Ultra 3, 68-Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 4-1. EFI Boot Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 4-2. MP Welcome Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 5-1. Front Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 5-2. QuickFind Diagnostic Label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 5-3. I/O Baseboard LEDs, Buttons and Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 5-4. Offline Diagnostic Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
About This Document
This document describes how to operate and maintain your hp Integrity rx4640 Server, Regulatory Model
Number: RSVLA-0201.
The document printing date and part number indicate the document’s current edition. The printing date will
change when a new edition is printed. Minor changes may be made at reprint without changing the printing
date. The document part number will change when extensive changes are made.
Document updates may be issued between editions to correct errors or document product changes. To ensure
that you receive the updated or new editions, you should subscribe to the appropriate product support service.
See your HP sales representative for details.
IMPORTANT
The latest version of this document can be found online at http://docs.hp.com.
What’s in This Document
The hp Integrity rx4640 Operations Guide contains these chapters:
•
Chapter 2, “Controls, Ports, and Indicators.” Use this chapter to learn about the front panel controls,
rear panel ports and connectors, and all system LED locations and functions.
•
Chapter 3, “External Connectors.” Use this chapter to learn about all external connectors, plugs, and
their pinouts.
•
Chapter 4, “Utilities.” Use this chapter to learn how to navigate in the EFI and management processor
environments.
•
Chapter 5, “Troubleshooting.” Use this chapter to learn how to perform minimal troubleshooting of
your system
•
Chapter 6, “Specifications.” Use this chapter to learn the basic mechanical specifications of your HP
Server.
Typographical Conventions
This document uses the following conventions.
Title
The title of a document or a CD.
KeyCap
The name of a keyboard key. Note that Return and Enter both refer to the same key.
Emphasis
Text that is emphasized.
Bold
Text that is strongly emphasized, such as the summary text in bulleted paragraphs.
ComputerOut
Text displayed by the computer.
UserInput
Commands and other text that you type.
Command
A command name or qualified command phrase.
About This Document
Related Documents
10
Related Documents
The HP Server Documentation CD-ROM has been provided with the server. It contains a documentation set
for the server, including localized versions of key documents. Included on the CD-ROM are the Site
Preparation and Operations guides, which contain in-depth troubleshooting and installation information.
The CD will autorun when you insert it into a Windows workstation, or, point your browser at the index.htm
file located under the Start directory of the CD. All users, including UNIX/Linux, can access a complete
manual set by viewing the directory manuals. The manuals are in Adobe Acrobat Reader (pdf) format.
IMPORTANT
The latest version of this document can be found online at http://docs.hp.com.
HP Encourages Your Comments
HP encourages your comments concerning this document. We are truly committed to providing
documentation that meets your needs.
Please send any comments by contacting us at http://docs.hp.com/assistance/index.html.
Please include document title, manufacturing part number, and any comment, error found, or suggestion for
improvement you have concerning this document.
Where to Get Help
For online access to technical support information, self-solve tools, online assistance, community forums of IT
experts, broad multivendor knowledge base, and monitoring and diagnostic tools, go to
http://www.hp.com/support.
For the latest information on HP-UX patches, check the HP IT Resource Center at http://itrc.hp.com.
Information to Collect Before You Contact Support
Before you contact HP support, you should:
Step 1. Check information on troubleshooting and attempt to solve the problem. See the hp Integrity
rx4640 Installation Guide.
•
Note failure symptoms and error indications (LEDs and messages) by checking the SEL and
FPL logs.
•
Try to determine precisely what did or did not happen.
Step 2. Collect the following information:
•
The model number of your server (for example, rx4640).
About This Document
Where to Get Help
11
•
The product number of your server. This can be found on the identification label, which is found
at the front of the unit (typically A6837B A6838B, and so on).
•
The serial number of your server. This can be found on the identification label.
Step 3. Become familiar with your system configuration:
•
Are you using the LAN, RS232, or web interface to monitor the server?
•
How many processors, DIMMs, and PCI cards have been installed?
•
What versions of processor, memory, and PCI cards are used and where are they installed?
•
What accessories are installed?
Step 4. Determine the following:
•
Which firmware versions are in use?
•
When did the problem start?
•
Have recent changes been made to the system?
•
Which operating system and version is in use?
Controls, Ports, and Indicators
Introduction
This chapter describes the controls, ports, and indicators found on the front panel, rear panel, and internal
locations of the hp Integrity rx4640 Server. The hp Integrity rx4640 Server comes in either rack mount or
pedestal configurations.
Controls, Ports, and Indicators
Front Panel
14
Front Panel
The front panel of the hp Integrity rx4640 Server provide the controls and indicators commonly used for
operation.
Figure 2-1
Front View with Bezel
Figure 2-2
Accessing the Control Panel
Control Panel
Controls, Ports, and Indicators
Front Panel
15
Figure 2-3
Control Panel
Table 2-1
Control Panel LED Definitions
LED/
Button
State
Flash Rate
Color
Description
System
Running
Steady
Green
Green: System normal—OS up and running
System
Booting
Flashing at
0.5Hz
Green
Flashing Green: OS booting or at EFI
System
Attention
Flashing at
1 Hz
Yellow
Flashing Yellow: Warning-system needs
attention. Redundancy lost, component
failure pending.
System
Fault
Flashing at
2 Hz
Red
Flashing Red: Hard fault. system halted
System
Off
Off
N/A
Off: System off
Power
On
Steady
Green
Green: Power normal
Power
On
Steady
Yellow
Flashing Yellow: Housekeeping voltage
present
Power
Off
Off
Off
Off: Power off
Disk LED
Flashing at
rate of disk
activity
Green
Flashing Green: Disk activity
Thermal
LED
OK
Steady
Green
Green: Thermal OK
Thermal
LED
Warning
Flashing at
1 Hz
Yellow
Flashing Yellow: Thermal warning
Locator
LED/Button
Flashing at
1 Hz
Blue
Flashing Blue: System locator LED may be
remotely or locally activated/deactivated
Power LED
Power Button
TOC/NMI Button
System LED
Disk LED
Thermal LED
Locator
Button/LED
Controls, Ports, and Indicators
Additional Controls and Indicators
16
Switch/Button and Front Control Panel LED Definitions
Additional Controls and Indicators
Storage devices have additional LEDs showing their status.
Hot-Plug Disk Drive Indicators
The hot-swap disk drives have two LEDs per drive, as described below.
•
Drive Status LED - The drive status LED is tri-color and may display green, amber, or yellow at any given
time. These colors indicate a normal, warning, or failure condition.
•
Drive Activity LED - The drive activity LED is green and indicates disk drive activity. This LED is
controlled by the disk drive directly and turns on when a drive is accessed.
Figure 2-4
Hot-Swap Disk Drive LED Indicators
Table 2-2
Switch/Button LED Definitions
Button/Switch
Description
Power Button
The power switch turns the HP Server power on or off. If sleep states are
available, it also transitions between power-on and sleep states.
Sleep states are NOS dependent and only available if your NOS supports
power management based on the ACPI (Advanced Configuration and Power
Interface) standard.
NMI Button
(Paper clip may be used to
depress button.)
Press the nonmaskable interrupt (NMI) switch before restarting the system
after a hung condition occurs. NMI provides crash dump capture capability.
Obtain a system hardware status dump to use in root cause analysis and
debugging.
Table 2-3
Hot-Swap Disk Drive LED Definitions
LED
Description
Activity LED
Flashing green
Drive access under hard drive control.
Status LED
Activity LED
Controls, Ports, and Indicators
Additional Controls and Indicators
17
DVD–ROM/DVD-R/DVD-RW Drives
The HP Server is delivered with one DVD-ROM drive (DVD-R and DVD-RW optional). Each of these devices
has one activity LED.
Figure 2-5
DVD–ROM Drive
QuickFind Diagnostic Panel
The QuickFind diagnostic panel has 27 single color LEDs and one multi-color LED for temperature. The
LEDs are normally off. The appropriate LED is turned on when an error is detected or a replacement part is
required.
Status LED
Solid Amber
Amber
Green
Blank
Drive fault.
Missing management board or jumper cable. For all HDD on
SCSI bus A and/or B.
Drive/Slot normal (drive present).
Pass through mode.
Table 2-4
DVD Drive LED Definitions
LED
Description
Activity LED
Flashing green
Drive access under hard drive control.
Table 2-3
Hot-Swap Disk Drive LED Definitions (Continued)
LED
Description
Eject Button
Activity LED
Emergency Eject
Controls, Ports, and Indicators
Additional Controls and Indicators
18
Accessing the QuickFind Diagnostic Panel
You can access the QuickFind diagnostic panel by removing the top cover (refer to the hp Integrity rx4640
Installation Guide). You can use the QuickFind diagnostic panel as an aid in troubleshooting. For a complete
description of QuickFind diagnostic LED states, see the hp Integrity rx4640 Installation Guide.
Figure 2-6
QuickFind Diagnostic Panel
Table 2-5
QuickFind Diagnostic Panel LEDs
Item
LED 0
LED 1
LED 2
LED 3
Details
Processor
Socket 0
Socket 1
Socket 2
Socket3
If the System LED (on front panel) is in
the attention or fault state and the
processor LED is lit, then the processor or
voltage regulator has failed—the
processor module in the specified socket
needs to be replaced.
If the thermal LED is in the warning or
critical state and the processor LED is lit,
then the processor exceeded the warning
or critical level.
Controls, Ports, and Indicators
Additional Controls and Indicators
19
Subsystem
CPU
board
Memory
board
I/O board
n/a
A soldered voltage regulator has
failed—the specified board must be
replaced.
I/O VRM
12 volt
5 volt
3 volt
n/a
A plug-in voltage regulator has
failed—specific VRM must be replaced.
CPU VRM
n/a
n/a
n/a
n/a
n/a
Fan Module
0
1
2
n/a
One or both fans in a fan module has
failed—the module must be replaced.
Fan 2 is in front of the power supplies.
Memory
Bank X
(0-7)
DIMM xA
DIMM
xB
DIMM xC
DIMM
xD
The specified DIMM has failed—the
DIMM must be replaced.
If all the LEDs for a rank (0-7) are lit and
the Memory Config Error LED is lit then
the DIMMs in the specified rank are
mismatched—replace mismatched DIMM.
Check
Power
Supply
n/a
n/a
n/a
One of the power supply or power supply
fans has failed—replace the power supply.
The faulty power supply LED (located on
power supply) will be lit.
Memory
Config
Error
n/a
n/a
n/a
The DIMMs in a rank are mismatched. All
the DIMMs in the specified rank (0-7) will
be lit.
Processor
Config
Error
n/a
n/a
n/a
The processors are mismatched—replace
mismatched processor.
Missing
Component
n/a
n/a
n/a
A required component(s) is not installed in
the system and thus preventing power up.
System
Temp
n/a
n/a
n/a
The internal temperature of the server
has exceeded the warning or critical level.
Check
Event Log
n/a
n/a
n/a
An event has occurred that requires
attention.
Table 2-5
QuickFind Diagnostic Panel LEDs (Continued)
Item
LED 0
LED 1
LED 2
LED 3
Details
Controls, Ports, and Indicators
Additional Controls and Indicators
20
I/O Baseboard LED Indicators
Various LEDs, sensors, reset, and attention buttons are found on the I/O baseboard.
Figure 2-7
I/O Baseboard LEDs, Buttons, and Sensors
Table 2-6
I/O Baseboard LEDs, Buttons, and Sensors
LED/Button
Color
Status
Condition
12V VRM
Power LED
Green
On
12V VRM is functioning.
5V VRM Power
LED
Green
On
5V VRM is functioning.
PCI Attention
LED
6X
PCI Attention
Button (Doorbell)
6X
PCI Power LED
6X
PCI Attention LED
6X
3.3VSB
Power
LED
BMC
Reset
Button
12V VRM LED
3.3V VRM LED
Locator Button/LED
5V VRM
LED
MP Soft
Reset
Button
MP Self-Test
LED
MP Heartbeat LED
BMC Heartbeat LED
Battery
Controls, Ports, and Indicators
Rear Panel
21
Rear Panel
The HP Server rear panel includes communication ports, I/O ports, AC power connectors, two power supply
bays, attention LED indicators for the hot-plug PCI boards, and the locator LED/button. LEDs located on the
rear panel of the HP Server signal the operational status of:
•
Power supplies
•
Management processor LAN
•
2 Port Gigabit Ethernet card LAN
3.3V VRM
Power LED
Green
On
3.3V VRM is functioning.
MP Heartbeat
Green
Blinking
The management processor is functioning correctly.
MP Self Test
LED
Amber
On
Off
The management processor is executing the internal self test.
The management processor has passed the internal self test.
BMC Heartbeat
Green
Blinking
The baseboard management controller is functioning correctly.
3.3VSB Power
LED
Green
On
Standby power is available.
MP Soft Reset
Button
N/A
Press
Resets the management processor values.
Table 2-6
I/O Baseboard LEDs, Buttons, and Sensors (Continued)
LED/Button
Color
Status
Condition
Controls, Ports, and Indicators
Rear Panel
22
•
PCI slots 3-8
Figure 2-8
Rack Mount and Pedestal Rear View
Gigabit Ethernet LAN LEDs
MP LAN LEDs
6 PCI Attention LEDs
Locator Button/LED
Controls, Ports, and Indicators
Rear Panel
23
Power Supply Status LEDs
Each 200-240 VAC power supply unit has three status LEDs located on the power supply rear side.
Consolidated status of all power supplies is reported by the front control panel by the power status LED.
Figure 2-9
Power Supply Status LED
Table 2-7
Power Supply Status LED
Power
LED-Green
Predict Fail
LED-Amber
Fail
LED-Amber
Status
Off
Off
Off
No AC power applied to all PSUs.
Off
Off
On
No AC power applied to this PSU only.
Blinking
Off
Off
AC present/standby outputs on.
On
Off
Off
PSU DC outputs on and OK.
Off
Off
On
Power supply failure.
On
Blinking
Off
Predictive failure—PSU about to fail because of poorly
performing fan.
On
Off
Blinking
Current limit on 48 VDC output.
Predict Fail
LED-Amber
Power LED-Green
Fail LED-Amber
Controls, Ports, and Indicators
Rear Panel
24
Management Processor LAN LEDs
The internal management processor (MP) LAN uses an RJ-45 type connector. This connector has two LEDs
(LAN link and LAN activity) that signal status and activity.
Figure 2-10
MP LAN LEDs
Locator LED and Button
An LED and button is provided on the rear panel of the server. Another single blue LED and button is on the
front control panel that enables/disables the locator function. See Figure 2-10, “MP LAN LEDs.”
Table 2-8
MP LED Status Descriptions
LED
Condition
Status
10M amber
On
Linked at 10MBps—no
activity
10M amber
Blinking
Linked at
10MBps—activity
present
100M green
On
Linked at
100MBps—no activity
100M green
Blinking
Linked at
100MBps—activity
present
10M Link/Activity, Amber LED
100M Link/Activity, Green LED
Locator Button and LED
USB Ports
Controls, Ports, and Indicators
Rear Panel
25
Gigabit Ethernet Card LAN LEDs
(Core I/O)
The 2-Port core I/O Gigabit Ethernet card uses an RJ-45 LAN connector. This connector has 4 LEDs (3 LAN
link and 1 LAN activity) that signal link speed and activity.
Figure 2-11
Core I/O LAN Port LEDs
Table 2-9
Core LED Status Descriptions
LED
Condition
Status
Activity
Green—on
Linked—no activity
Activity
Green—off
No link
Activity
Green—blinking
Linked—activity present
1000
Green—on
Link speed—1000 MBps
100
Green—on
Link speed—100 MBps
10
Green—on
Link speed—10 MBps
RJ-45 Connector
1000
100
Activity
10
The following ports and connectors are found on the rear panel of the hp Integrity rx4640 Server. The SCSI
Host Bus Adapter card in slot 1 and the Gigabit Ethernet card in slot 2 are factory installed.
Figure 3-1
Rear View
Universal Serial Bus (USB) Ports
Figure 3-2
USB Port Connector
Table 3-1
USB Pinouts
Pin Number
Signal Description
1
+5VDC
2
MR
HBA, Ultra 3 SCSI, 68 Pin
Gigabit Ethernet LAN Port
3 Serial Ports
VGA Port
Management Processor
LAN Port
USB Ports
Local
Ax
Remote
1
2
3
4
1
2
3
4
Video Port Connector
3
PR
4
Ground
Table 3-2
Video Connector Pinouts
Pin Number
Signal Description
Pin Number
Signal Description
1
Red
9
+5VDC
2
Green
10
Sync return (ground)
3
Blue
11
Not used
4
Not used
12
Monitor ID bit 1
5
Video Self Test (ground)
13
Horizontal sync (+)
6
Red return (ground)
14
Vertical sync (-)
7
Green return (ground)
15
Video ID bit 2
8
Blue return (ground)
Table 3-1
USB Pinouts (Continued)
Pin Number
Signal Description
Serial Port Connector
Management Processor LAN Port
Figure 3-5
Management Processor Port
Table 3-3
Serial Port Pinouts
Pin Number
Signal Description
1
Data carrier detect
2
Receive data
3
Transmit data
4
Data Term ready
5
Ground
6
Data set ready
7
Request to send
8
Clear to send
9
Ring indicator
Table 3-4
Management Processor LAN Port Pinouts
Pin Number
Signal Description
1
TXP
2
TXN
3
RXP
5
4
3
2
1
9
8
7
6
Green
1
Yellow
8
Additional Ports on Accessory Boards
Gigabit Ethernet (LAN) Port
Figure 3-6
LAN Port
4
Not used
5
Not used
6
RXN
7
Not used
8
Not used
Table 3-5
LAN Port Pinouts
Pin Number
Signal Description
1
RXP
2
RXN
3
TXP
4
Not used
5
Not used
6
TXN
7
Not used
8
Not used
Table 3-4
Management Processor LAN Port Pinouts (Continued)
Pin Number
Signal Description
1
8
SCSI Port, Ultra 3, 68-Pin
Two Ultra 3, 68-pin SCSI connectors are located on the host bus adapter (HBA) located in PCI slot 1. The
upper connector supports SCSI channel A and the lower connector supports SCSI channel B.
Figure 3-7
SCSI Port, Ultra 3, 68-Pin
Table 3-6
SCSI Port Pinouts
Pin Number
Signal Description
Pin Number
Signal Description
1
S1 (+DB 12)
35
S35 (-DB 12)
2
S2 (+DB 13)
36
S36 (-DB 13)
3
S3 (+DB 14)
37
S37 (-DB 14)
4
S4 (+DB 15)
38
S38 (-DB 15)
5
S5 (+DB P1)
39
S39 (-DB P1)
6
S6 (+DB 0)
40
S40 (-DB 0)
7
S7 (+DB 1)
41
S41 (-DB 1)
8
S8 (+DB 2)
42
S42 (-DB 2)
9
S9 (DB 3)
43
S43 (-DB 3)
10
S10 (+DB 4)
44
S44 (-DB 4)
11
S11 (+DB5)
45
S45 (-DB 5)
12
S12 (+DB 6)
46
S46 (-DB 6)
13
S13 (+DB 7)
47
S47 (-DB 7)
14
S14 (+DB P)
48
S48 (-DB P)
15
S15
49
S49
16
S16 (DIFFSENS)
50
S50
17
S17 (TERMPWR)
51
S51 (TERMPWR)
18
S18 (TERMPWR)
52
S52 (TERMPWR)
19
S19 (RESERVED)
53
S53 (RESERVED)
20
S20
54
S54
35
1
68
34
S31 (+DB 8)
65
S65 (-DB 8)
32
S32 (+DB 9)
66
S66 (-DB 9)
33
S33 (DB 10)
67
S67 (-DB 10)
34
S34 (DB 11)
68
S68 (-DB 11)
Table 3-6
SCSI Port Pinouts (Continued)
Pin Number
Signal Description
Pin Number
Signal Description
Extensible Firmware Interface (EFI) Boot Manager
EFI (Extensible Firmware Interface) is an OS and platform-independent boot and preboot interface. EFI lies
between the OS and platform firmware, allowing the OS to boot without having details about the underlying
hardware and firmware. EFI supports boot devices; uses a flat memory model; and hides platform and
firmware details from the OS.
NOTE
EFI and Pre-OS System Environment (POSSE) are similar. EFI is an Intel specification,
whereas POSSE is the HP implementation that aids HP support.
EFI consolidates boot utilities found in PA-RISC based systems, such as the Boot Console Handler (BCH),
and platform firmware into a single platform firmware. EFI allows the selection of any EFI OS loader from
any boot medium that is supported by EFI boot services. An EFI OS loader supports multiple options on the
user interface.
EFI supports booting from media that contain an EFI OS loader or an EFI-defined System Partition. An
EFI-defined System Partition is required by EFI to boot from a block device.
Figure 4-1
EFI Boot Sequence
EFI
Driver
EFI
Application
EFI
Bootcode
OS Loader
Retry
FAILURE
EFI API
Platform
Init
EFI Image
Load
EFI
OS Loader
Load
Boot Services
Terminate
Standard
firmware
platform
initialization
Drivers and
application
loaded
iteratively
Boot from
ordered list
of EFIOS
loaders
Operation
handed off to
OS Loader
API specified
Value add implementation
Boot manager
EFI transfers
Extensible Firmware Interface (EFI) Boot Manager
34
The EFI boot manager loads EFI applications (including OS first stage loader) and EFI drivers from an
EFI-defined file system or image loading service. NVRAM variables point to the file to be loaded. These
variables contain application-specific data that is passed directly to the EFI application. EFI variables
provides system firmware a boot menu that points to all the operating systems, even multiple versions of the
same operating systems.
The EFI boot manager allows you to control the server’s booting environment. Depending on how you have
configured the boot options, after the server is powered up the boot manager presents you with different ways
to bring up the system. For example, you can boot to the EFI shell, to an operating system located on the
network or residing on media in the server, or the Boot Maintenance menu.
•
Boot from a File—Automatically adds EFI applications as boot options or allows you to boot from a
specific file. When you choose this option, the system searches for an EFI directory. If the EFI directory is
found, then it looks in each of the subdirectories below EFI. In each of those subdirectories, it looks for the
first file that is an executable EFI application. Each of the EFI applications that meet this criterion can
be automatically added as a boot option. In addition, legacy boot options for A: and C: are also added if
those devices are present. You can also launch a specific application without adding it as a boot option. In
this case the EFI boot manager searches the root directories and the \EFI\TOOLS directories of all of the
EFI system partitions present in the system for the specified EFI application.
•
Add a Boot Option—Adds a boot option to the EFI boot manager. You specify the option by providing the
name of the EFI application. Along with the name you can also provide either ASCII or UNICODE
arguments the file might use. Given the EFI application name and any options, the EFI boot manager
searches for the executable file in the same directories as described in “Boot from a File” option. When the
file is found, it is executed.
•
Delete Boot Options—Deletes a specific boot option or all boot options
•
Change Boot Order—Controls the relative order in which the EFI boot manager attempts boot options.
For help on the control key sequences you need for this option, refer to the help menu.
•
Manage BootNext Setting—Selects a boot option to use one time (the next boot operation)
•
Set Automatic Boot Timeout—Defines the value in seconds that pass before the system automatically
boots without user intervention. Setting this value to zero disables the timeout feature.
•
Exit—Returns control to the EFI boot manager main menu. This displays the active boot devices,
including a possible integrated shell (if the implementation is so constructed).
EFI Commands
Table 4-1 lists EFI commands for the hp Integrity rx4640 Server. The equivalent BCH commands found in
PA-RISC based systems are also listed.
Table 4-1
EFI Commands
EFI Shell
Command
BCH
Command
Equivalent
BCH Command Parameters
Definition
These commands are found in all other menus
info boot
Boot
[PRI|HAA|ALT|]
Boot from specified path
help
HElp
[
Extensible Firmware Interface (EFI) Boot Manager
35
reset
RESET
Reset the system (to
allow reconfiguration of
complex
exit (at EFI shell)
MAin
Return to the main menu
MAin
EFI boot manager
“change boot
order”
PAth
[PRI|HAA|ALT|CON|KEY|
]
Display or modify a path
bcfg
SEArch
[ALL]
Search for boot devices
bcfg
SEArch
[DIsplay|IPL] []
Search for boot devices
many commands
offer a [-b]
parameter to cause
25 line breaks
ScRoll
[ON|OFF]
Display or change
scrolling capability
COnfiguration
autoboot
AUto
[BOot|SEarch|STart] [ON|OFF]
Display or set the auto
start flag
info boot
BootID
[[]]
Display or set processor
boot identifier
EFI boot manager
Boot info
Display boot-related
information
autoboot
BootTimer
[0-200]
Seconds allowed for boot
attempt
cpuconfig
CPUconfig
[][ON|OFF]]
Config/deconfig processor
boottest
FastBoot
[ON|OFF] or [test] [RUN|SKIP]
Display or set boot tests
execution
date
Time
[cn:yr:mo:dy:hr:mn[:ss]]
Read or set the date
time
Time
[cn:yr:mo:dy:hr:mn[:ss]]
Read or set the real time
clock
INformation
info all
ALL
Display all system
information
info boot
BootINfo
Display boot-releated
information
Table 4-1
EFI Commands (Continued)
EFI Shell
Command
BCH
Command
Equivalent
BCH Command Parameters
Definition
Extensible Firmware Interface (EFI) Boot Manager
36
info cpu
CAche
Display cache
information
info chiprev
ChipRevisions
Display revision number
of major VLSI
MP command
FRU
Display FRU information
info fw
FwrVersion
Display firmware version
for PDC, ICM, and
complex
info io
IO
Display firmware version
for PDC, ICM, and
complex
LanAddress
LanAddress
Display core LAN station
address
info mem
Memory
Display memory
information
info cpu
PRocessor
Display processor
information
SERvice
errdump clear
CLEARPIM
Clear (zero) the contents
of PIM
mm
MemRead
[] []
Read memory locations
scope of page
deallocation
PDT
PDT
Display or clear the page
deallocation table
errdump mca
errdump cmc
errdump init
PIM
[]
[HPMC|LPMC|TOC|ASIC]]
Display PIM information
(processor internal
memory)
Table 4-1
EFI Commands (Continued)
EFI Shell
Command
BCH
Command
Equivalent
BCH Command Parameters
Definition
This section describes the EFI/POSSE commands developed for the server.
NOTE
EFI and Pre-OS System Environment (POSSE) are similar. EFI is an Intel specification,
whereas POSSE is the HP implementation that aids HP support.
help
Provides information on the EFI shell commands. It also has an additional feature to aid those familiar with
the BCH menus to adjust to their equivalent functions in EFI.
Syntax
help [-b]
help [-b]
help [-b] bch
Parameters
-b
Enable page breaking
category
Category of commands to view help on commands
cmd
Shell command name on which to provide verbose information
bch
Display the list of BCH commands and their corresponding EFI
bchmenu
BCH menu name taken from the top level of the BCH menu
bchcmd
BCH command on which to display information
Operation
If help is invoked with no parameters, it displays a list of shell command categories. To list all of the
commands within a category, the user should type help (see examples). If invoked with the -b
switch, any output longer than one page pauses after each page is displayed. If a shell command name is used
as a parameter, verbose help is displayed for that command.
If help is invoked with the bch option, it displays a list of BCH commands and their corresponding
EFI/POSSE commands. It instructs the user to repeat the command line followed by a menu name for more
information on that menu. If help is invoked followed by bch and a menu name, it displays a list of commands
that appear under that BCH menu. The user may then invoke help followed by bch, the menu name, and a
BCH command name to display information on that command. This would point the user to the command
that has taken the place of that BCH functionality, or will inform the user that the functionality no longer
exists. As a shortcut, the user may enter help followed by bch and a BCH command name to go straight to
that command.
Example 4-1
help Command
Shell> help
List of classes of commands:
boot
-- Booting options and disk-related commands
configuration -- Changing and retrieving system information
devices
-- Getting device, driver and handle information
memory
-- Memory related commands
shell
-- Basic shell navigation and customization
-- EFI shell-script commandsType "help" followed by a class name for a list of commands in
that class
Type "help" followed by command name for full documentation
Example 4-2
help configuration Command
Shell> help configuration
Configuration commands:
cpuconfig
-- Deconfigure or reconfigure cpus
date
-- Display or set date
err
-- Display or set error level
esiproc
-- Make an ESI call
errdump
-- View/Clear logs
info
-- Display hardware information
monarch
-- View or set the monarch processor
palproc
-- Make a PAL call
salproc
-- Make a SAL call
time
-- Display or set time
ver
-- Displays version info
Type "help" followed by command name for full documentationon that command.
Type "help -a" to display a list of all commands.
Example 4-3
help cpuconfig Command
Shell> help cpuconfig
CPUCONFIG [cpu] [on|off]
cpu
Specifies which cpu to configure
on|off Specifies to configure or deconfigure a cpu
Notes:
1. Cpu status will not change until next boot
Examples:
* To deconfigure CPU 0
fs0:\> cpuconfig 0 off
CPU will be deconfigured on the next boot
* To display configuration status of cpus
fs0:\> cpuconfig
Example 4-4
help bch Command
COnfiguration
help bch co
INformation
help bch in
PAth
help bch pa
ScRool
help bch sr
SEArch
help bch sea
SERvice
help bch ser
BOot
help bch bo
HElp
help bch he
RESET
help bch reset
MAin
help bch ma
For more help on one of the commands above, at the prompt type:
help bch COMMAND
Sets the baud rate and communication settings for a UART.
Syntax
baud
Parameters
0 through the total number of UARTS minus one
baud rate.
Operation
This command is used to change the speed for a UART in the system. This command works for all UARTs
visible to EFI/POSSE. If the UART is part of PDH space and is initialized by the core firmware, this command
communicates the settings to core firmware so the UART can be initialized with the new settings on the next
boot. System default is 9600 baud.
Other Communication parameters are listed in Table 4-2.
boottest
Interacts with the speedy boot variable allowing it to be set appropriately.
Syntax
boottest
Displays status of all speedy boot bits
boottest on
Run all tests (for a normal boot time)
boottest off
Skip all tests (for a faster boot time)
boottest [test]
Displays status of specific Speedy Boot bit
boottest [test] [on|off]
Sets or clears a specific Speedy Boot bit
Parameters
[test]
Each test can be set or cleared:
booting_valid
Enable/disable system firmware response to BOOTING
bit. If OS Speedy Boot aware set to on.
early_cpu
Enable/disable early CPU selftests.
late_cpu
Enable/disable late CPU selftests.
platform
Enable/disable system board hardware tests.
chipset
Enable/disable CEC tests.
Table 4-2
Communications Parameters
Parameter
Value
RECEIVE_FIFO_DEPTH
1
TIMEOUT
1000000
PARITY
No parity
DATA_BITS
8
STOP_BITS
1
CONTROL_MASK
0
Enable/disable EFI driver Core I/O tests.
mem_init
Enable/disable memory initialization.
mem_test
Enable/disable full destructive memory tests.
Example 4-5
boottest Command
Shell> boottest
BOOTTEST Settings Default Variable
Selftest
Setting
-------------
-------------------------
booting_valid
On (OS speedy boot aware)
early_cpu
Run this test
late_cpu
Run this test
platform
Run this test
chipset
Run this test
io_hw
Run this test
mem_init
Run this test
mem_test
Run this test
Example 4-6
boottest early_cpu off Command
Shell> boottest early_cpu off
BOOTTEST Settings Default Variable
Selftest
Setting
-------------
-------------------------
booting_valid
On (OS speedy boot aware)
early_cpu
Skip this test
late_cpu
Run this test
platform
Run this test
chipset
Run this test
io_hw
Run this test
mem_init
Run this test
mem_test
Run this test
cpuconfig
Displays the config/deconfig state of processors in the system and allows the user to configure or reconfigure
processors.
Syntax
cpuconfig
Parameters
specify a processor
state to set the processor to
Operation
Issuing cpuconfig with no parameters displays the config/deconfig status of all processors. A user can
reconfigure CPUs by specifying a CPU number and a state (on or off). If a valid state is entered and is
different from the current state of a CPU, its status changes on the next boot. The last remaining configured
CPU in a system cannot be deconfigured.
Example 4-7
cpuconfig Command
Shell>
cpuconfig
PROCESSOR INFORMATION
# of
L3
L4
Family/
CPU
Logical
Cache
Cache
Model
Processor
cpuconfig 2 Command
Shell> cpuconfig 2 off
CPU will be deconfigured on next boot.
Shell> cpuconfig
PROCESSOR INFORMATION
# of
L3
L4
Family/
CPU
Logical
Cache
Cache
Model
Processor
Slot
CPUs
Speed
Size
Size
(hex.)
Rev
State
---
-------
---------
----
-----
------
----
----------
0
1
1 GHz
3 MB
None
1F/00
B2
Active
1
1
1 GHz
3 MB
None
1F/00
B2
Active
2
1
1 GHz
3 MB
None
1F/00
B2
Sched Deconf
3
1
1 GHz
3 MB
None
1F/00
B2
Active
default
Allows the user to restore NVM to default values and clear NVM storage values.
Syntax
default
[efi|sal]
default
clear [bmc|efi|sal]
Parameters
clear
clears NVM storage values
Operation
Default sets NVM and Stable Store values to predefined default values. To the normal user only a subset of
values are available for default. Executing “default clear” resets the system.
errdump
Displays the contents of processor internal memory logged on the first MCA for all processors present in the
system.
Syntax
errdump [mca | cpe | cmc | init | la | clear]
Parameters
mca
dumps the Machine Check Abort error log
cpe
dumps the Corrected Platform Error log
cmc
dumps the Corrected Machine Check log
init
dumps the Initialization log
la
dumps the Logic Analyzer log
clear
erases all of the logs (mca, cpe, cmc, init, la)
If a user enters no parameters, the usage is displayed. Otherwise, the specified error log is displayed. Adding
-n to the clear parameter disables the confirmation prompt. (The errdump command can also be accessed via
the System Configuration menu.)
info
Allows the user to display most system information.
Syntax
info [ -b] [target]
Parameters
target:
valid targets are:
all
display everything
cpu
display information on cpus
cache
display information on cache
mem
display information on memory
io
display information on io
boot
display boot-related information
chiprev
display information on chip revisions
fw
display firmware version information
sys
display system information
warning
display warning and stop boot information
Example 4-9
info -b all Command
Shell> info -b all
PROCESSOR INFORMATION
# of
L3
L4
Family/
CPU
Logical
Cache
Cache
Model
Processor
Slot
CPUs
Speed
Size
Size
(hex.)
Rev
State
----
-------
--------
------
------
-------
----
------- -
0
1
1 GHz
3 MB
None
1F/01
B2
Active
1
1
1 GHz
3 MB
None
1F/01
B2
Active
2
1
1 GHz
3 MB
None
1F/01
B2
Sched Deconf
3
1
1 GHz
3 MB
None
1F/01
B2
Active
MEMORY INFORMATION
Extender 0:
--- DIMM A -----
---- DIMM B -----
----DIMM C -----
---- DIMM D -----
DIMM
Current
DIMM
Current
DIMM
Current
DIMM
Current
---
------ ----------
------ -----------
------ ----------
----- -------------
0
256 MB
Active
256 MB
Active
256 MB
Active
256 MB
Active
1
----
----
----
----
2
----
----
----
----
3
----
----
----
----
4
----
----
----
----
5
----
----
----
----
Extender 1:
--- DIMM A -----
---- DIMM B -----
----DIMM C -----
---- DIMM D -----
DIMM
Current
DIMM
Current
DIMM
Current
DIMM
Current
---
------ ----------
------ -----------
------ ----------
----- -------------
0
256 MB
Active
256 MB
Active
256 MB
Active
256 MB
Active
1
----
----
----
----
2
----
----
----
----
3
----
----
----
----
: 1024 MB
Installed Memory : 1024 MB
I/O INFORMATION
BOOTABLE DEVICES
Order
Media Type
Path
----
---------- --------------------------------------------------------------------------------
1
HARDDRIVE
Acpi(HWP0002,0)/Pci(2|0)/Scsi(Puno,Luno)/HD(Part1,Sig3D1F1
86A-846F-11D1-FB49BB94A768)
2
HARDDRIVE
Acpi(HWP0002,0)/Pci(2|0)/Scsi(Pun2,Luno)/HD(Part1,Sig965900000
3
CDROM
Acpi(HWP0002,0)/Pci(2|1)/Scsi(Pun4,Luno)/CDROM(Entry0)
4
HARDDRIVE
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|1)Scsi(Pun2,Luno)/HD(Part2,SigA45AC380-2588
-11D6-B48C-806D6172696F)
5
HARDDRIVE
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|1)/Scsi(Pun2,Luno)/HD(Part2,Sig9C82CD80-70D
2-4E88-A374-B029EBF1D8E4)
Seg
Bus
Dev
Fnc
Vendor
Device
Slot
#
#
#
#
ID
ID
#
Path
---
---
---
---
------
-------
----
-------------
00
00
01
00
0x103C
0x1290
01
Acpi(HWP0002,0)/Pci(1|0)
00
00
01
01
0x103C
0x1048
01
Acpi(HWP0002,0)/Pci(1|1)
00
00
02
00
0x1000
0x000B
01
Acpi(HWP0002,0)/Pci(2|0)
00
00
02
01
0x1000
0x000B
01
Acpi(HWP0002,0)/Pci(2|1)
00
00
04
00
0x1011
0x0026
02
Acpi(HWP0002,0)/Pci(4|0)
00
01
04
00
0x1033
0x0035
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|0)
00
01
04
01
0x1033
0x0035
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|1)
00
01
04
02
0x1033
0x00E0
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|2)
00
01
05
00
0x1002
0x5159
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(5|0)
00
20
01
00
0x1014
0x01A7
03
Acpi(HWP0002,100)/Pci(1|0)
00
21
01
00
0x1000
0x0021
03
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|0)
00
21
01
01
0x1000
0x0021
03
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|1)
00
21
04
00
0x14E4
0x1645
03
Acpi(HWP0002,100)/Pci(1|0)/Pci(4|0)
BOOT INFORMATION
Monarch CPU :
Current Preferred
Monarch
Monarch
Possible Warnings
-------
-------
------------------
0
0
AutoBoot : ON - Timeout is : 7 sev
Boottest
:
OS is not speedy boot aware
Selftest
Setting
---------
--------------------
early_cpu
Skip this test
late_cpu
Run this test
platform
Run this test
chipset
Run this test
io_hw
Run this test
mem_init
Run this test
mem_test
Run this test
LAN Address Information :
Lan Address
Path
-------------
---------------------
*Mac(00306E05B950)
Acpi(HWP0002,100)/Pci(1|0)/Pci(4|0)/Mac(00306E05B950
AWARE INFORMATION
verscode
: 00.00 xxx
datecode
:
xxxx
built with : xxxxxxx
Firmware Revision
: 2.01 (xxxx)
PAL_A Revision
: 7.31
SAL Spec Revision
: 7.31
SAL_A Revision
: 7.41
SAL_B Revision
: 7.31
EFI Spec Revision
: 7.41
EFI INTEL Drop Revision
: 7.31
EFI Build Revision
: 7.41
POSSE Revision
: 7.31
ACPI Revision
: 7.41
BMC Revision
: 7.31
IPMI Revision
: 7.41
SMBIOS Revision
: 7.31
Management Processor Revision
: 7.41
WARNING AND STOP BOOT INFORMATION
Warning [52] : A ROM revision is inconsistant with FIT or REVBLOCK
CHIP REVISION INFORMATION :
CHIP
Logical
Device
Chip
Type
ID
ID
Revision
-------------
-------
-------
---------
Memory Controller
0
122b
0022
Root Bridge
0
1229
0022
Host Bridge
0000
122e
0022
Host Bridge
0001
122e
0022
Host Bridge
0002
122e
0022
Host Bridge
0003
122e
0022
Host Bridge
0004
122e
0022
Hot Plug Controller
0
0
0110
Host Bridge
0005
122e
0022
Host Bridge
0006
122e
0022
Hot Plug Controller
0
0
0110
Host Bridge
7
0
0110
Hot Plug Controller
0
0
0110
Other Bridge
0
0
0002
Other Bridge
0
0
0007
Baseboard MC
0
0
0130
Example 4-10
info cpu Command
Shell> info cpu
PROCESSOR INFORMATION
# of
L3
L4
Family/
CPU
Logical
Cache
Cache
Model
Processor
Slot
CPUs
Speed
Size
Size
(hex.)
Rev
State
---
-------
---------
------
------
-------
----
------------
0
1
1 GHz
3 MB
None
1F/01
B2
Active
1
1
1 GHz
3 MB
None
1F/01
B2
Active
2
1
1 GHz
3 MB
None
1F/01
B2
Sched Deconf
3
1
1 GHz
3 MB
None
1F/01
B2
Active
Example 4-11
info mem Command
Shell> info mem
MEMORY INFORMATION
Extender 0:
--- DIMM A -----
---- DIMM B -----
----DIMM C -----
---- DIMM D -----
DIMM
Current
DIMM
Current
DIMM
Current
DIMM
Current
---
------ ----------
------ -----------
------ ----------
----- -------------
0
256 MB
Active
256 MB
Active
256 MB
Active
256 MB
Active
1
----
----
----
----
--- DIMM A -----
---- DIMM B -----
----DIMM C -----
---- DIMM D -----
DIMM
Current
DIMM
Current
DIMM
Current
DIMM
Current
---
------ ----------
------ -----------
------ ----------
----- -------------
0
256 MB
Active
256 MB
Active
256 MB
Active
256 MB
Active
1
----
----
----
----
2
----
----
----
----
3
----
----
----
----
4
----
----
----
----
5
----
----
----
----
Active Memory
: 1024 MB
Installed Memory : 1024 MB
Example 4-12
info io Command
Shell> info io
BOOTABLE DEVICES
Order
Media Type
Path
-----
----------
-------------------------------------------------------------------------
1
HARDDRIVE
Acpi(HWP0002,0)/Pci(2|0)/Scsi(Pun0,Lun0)/HD(Part1,
Sig3D1F186A-846F-11D1-8780-FB49BB94A768)
2
HARDDRIVE
Acpi(HWP0002,0)/Pci(2|0)/Scsi(Pun2,Lun0)/HD(Part1,Sig9659000)
3
CDROM
Acpi(HWP0002,0)/Pci(2|1)/Scsi(Pun4,Lun0)/CDROM(Entry0)
4
HARDDRIVE
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|1)/Scsi(Pun2,Lun0)/HD(Part1,
SigA45AC380-2588-11D6-B48C-806D6172696F)
5
HARDDRIVE
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|1)/Scsi(Pun2,Lun0)/HD(Part1,
Sig9C82CD80-70D2-4E88-A374-B029EBF1D8E4)
Seg
Bus
Dev
Fnc
Vendor
Device
Slot
#
#
#
#
ID
ID
#
Path
---
---
---
---
--------
-------
---
----------
00
00
01
00
0x103C
0x1290
01
Acpi(HWP0002,0)/Pci(1|0)
00
00
01
01
0x103C
0x1048
01
Acpi(HWP0002,0)/Pci(1|1)
00
00
02
00
0x1000
0x000B
01
Acpi(HWP0002,0)/Pci(2|0)
00
00
02
01
0x1000
0x000B
01
Acpi(HWP0002,0)/Pci(2|1)
00
00
04
00
0x1011
0x0026
02
Acpi(HWP0002,0)/Pci(4|0)
00
01
04
00
0x1033
0x0035
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|0)
00
01
04
01
0x1033
0x0035
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|1)
00
01
04
02
0x1033
0x00E0
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(4|2)
00
01
05
00
0x1002
0x5159
02
Acpi(HWP0002,0)/Pci(4|0)/Pci(5|0)
00
20
01
00
0x1014
0x01A7
03
Acpi(HWP0002,0)/Pci(1|0)
00
21
01
00
0x1000
0x0021
03
Acpi(HWP0002,100)/Pci(1|0)/Pci(1|0)
00
21
01
01
0x1000
0x0021
03
Acpi(HWP0002,100)/Pci(1|1)/Pci(1|1)
00
21
04
00
0x14E4
0x1645
03
Acpi(HWP0002,100)/Pci(1|0)/Pci(4|0)
Example 4-13
info boot Command
Shell> info boot
BOOT INFORMATION
Monarch CPU:
Current
Preferred
Monarch
Monarch
Possible Warnings
--------
---------
------------------
0
0
AutoBoot: on - Timeout is : 7 SEC
Boottest:
boottest
Settings Default Variable
OS is not speedy boot aware.
Selftest
Setting
----------
--------------
early_cpu
Skip this test
late_cpu
Run this test
platform
Run this test
chipset
Run this test
io_hw
Run this test
mem_init
Run this test
mem_test
Run this test
LAN AddressInformation:
LAN Address
Path
-------------------
--------------
*Mac(00306E05B950)
Acpi(HWP0002,100)/Pci(1|0)/Pci(4|0)/Mac(00306E05B950B)
lanaddress
Allows the user to display the core I/O MAC address.
Syntax:
lanaddress
Parameters
none
Example 4-14
lanaddress Command
Shell> lanaddress
LAN Address
Information
LAN ADDRESS
Path
------------------
--------------------------
*Mac(00306E05B950)
Acpi(HWP0002,100)/Pci(1|0)/Pci(4|0)/Mac(00306E05B950)
monarch
Displays or modifies the ID of the bootstrap processor. The preferred monarch number is stored in NVM.
Syntax
monarch
Parameters
specifies a cpu
Operation
If specified with no parameters, monarch displays the Monarch processor for the system. Specifying a
processor number alters the preferred Monarch processor. None of these changes takes affect until after a
reboot.
To view monarch: fs0 :\ monarch
| Processor
-----------------+-----------
current status
|
0
next boot status |
0
To set the monarch processor to 1: fs0 :\ monarch 1
| Processor
-----------------+-----------
current status
|
0
next boot status |
1
pdt
Displays or clears the contents of the Page Deallocation Table.
Syntax
pdt (clear)
Parameters
clears the pdt
Operation
With no options specified, the command displays the PDT information for the system. The PDT is cleared and
a reboot is required for memory reallocation and safe booting.
Example 4-16
pdt Command
Shell> pdt
PDT Information
Last Clear time: PDT has not been cleared
Number of total entries in PDT:
50
Number of used entries in PDT:
0
Number of free entries in PDT:
50
Number of single-bit entries in PDT:
0
Number of multi-bit entries in PDT:
0
Address of first multi-bit error:
x0000000000000000
Example 4-17
pdt clear Command
Shell> pdt clear
Are you sure you want to clear the PDT? [y/N] y
Shell>
Shell> pdt
PDT Information
Last Clear time: 10/21/01
5:00p
Number of total entries in PDT:
50
Number of used entries in PDT:
0
Number of free entries in PDT:
50
Number of single-bit entries in PDT:
0
Number of multi-bit entries in PDT:
0
Address of first multi-bit error: 0x0000000000000000
sysmode
Display or modify the system mode.
Syntax
sysmode
Parameters
sets system mode to normal
sets system mode to admin
sets system mode to service
Operation
If specified alone, sysmode displays the system mode. If a mode is specified as a parameter, then the system
mode is changed. This new mode takes effect immediately. The system mode is retained on successive boots.
Interaction with sysmode in a variety of scenarios is outlined below.
Example 4-18
sysmode Command
Shell> sysmode
System Mode: NORMAL
Shell> sysmode admin
You are now in admin mode.
Shell> sysmode service
You are now in service mode.
Shell> sysmode normal
You are now in normal mode
Specifying SCSI Parameters
49
Specifying SCSI Parameters
The following SCSI parameters may be configured for the SCSI board:
•
SCSI ID (SCSI initiator ID)
•
Maximum data transfer rate (SCSI rate)
•
Bus width
•
Whether the HBA is bootable (driver support)
•
Avoid bus resets (secondary cluster server)
Using the SCSI Setup Utility
Step 1. At the EFI shell prompt, type this command to map the parameters for all PCI cards installed in
the system:
info io
A list of all the devices that are installed in the hp Integrity rx4640 Server and managed by EFI
drivers is displayed. The output may look like this:
Seg
Bus
Dev
Fnc
Vendor
Device Slot
#
#
#
#
ID
ID
#
Path
---
---
---
---
------
------
---
-----------
00
20
02
00
0x14E4
0x1645
XX
Acpi(HWP0002,100)/Pci(2|0)
00
00
01
00
0x1033
0x0035
XX
Acpi(HWP0002,0)/Pci(1|0)
00
00
01
01
0x1033
0x0035
XX
Acpi(HWP0002,0)/Pci(1|1)
00
00
01
02
0x1033
0x00E0
XX
Acpi(HWP0002,0)/Pci(1|2)
00
00
02
00
0x1095
0x0649
XX
Acpi(HWP0002,0)/Pci(2|0)
00
00
03
00
0x8086
0x1229
XX
Acpi(HWP0002,0)/Pci(3|0)
00
20
01
00
0x1000
0x0030
XX
Acpi(HWP0002,100)/Pci(1|0)
00
20
01
01
0x1000
0x0030
XX
Acpi(HWP0002,100)/Pci(1|1)
00
40
01
00
0x1000
0x0021
03
Acpi(HWP0002,200)/Pci(1|0)
00
40
01
01
0x1000
0x0021
03
Acpi(HWP0002,200)/Pci(1|1)
00
60
01
00
0x1000
0x0021
02
Acpi(HWP0002,300)/Pci(1|0)
00
60
01
01
0x1000
0x0021
02
Acpi(HWP0002,300)/Pci(1|1)
00
80
01
00
0x8086
0x1229
01
Acpi(HWP0002,400)/Pci(1|0)
00
C0
01
00
0x1000
0x0021
04
Acpi(HWP0002,600)/Pci(1|0)
00
E0
01
00
0x103C
0x1290
XX
Acpi(HWP0002,700)/Pci(1|0)
00
E0
01
01
0x103C
0x1048
XX
Acpi(HWP0002,700)/Pci(1|1)
00
E0
02
00
0x1002
0x5159
XX
Acpi(HWP0002,700)/Pci(2|0)
In the example above, two SCSI boards are in the listing. The information for both channels of both
SCSI boards is shown in bold, for highlighting purposes.
For each channel of the SCSI board, you need to note certain information. As an example, look at
the information for the first SCSI board (the first two bold lines). For each channel of this SCSI
board, note the following information:
•
Bus #—identifies the bus the device is on; for the SCSI board, this is the same for both
channels. In this example, the bus number is 40.
•
Dev #—the ID the device is assigned on the bus; for the SCSI board, this is the same for both
channels. In this example, the SCSI board is device 01.
Specifying SCSI Parameters
50
•
Fnc #—identifies the channel of the device (00 for channel A, 01 for channel B, and so on). In
this example, because the SCSI board has two channels, one channel is 00 and the other is 01.
•
Vendor ID—shows the device’s vendor ID; for the SCSI board, this is the same for both
channels. For all SCSI board HBAs, the ID is 0x1000.
•
Device ID—shows the device’s device ID; for the SCSI board, this is the same for both
channels. For all SCSI board HBAs, the ID is 0x0021.
•
Slot #—identifies the physical card slot in the system where the HBA is installed; for the SCSI
board, this is the same for both channels. In this example, the HBA is in slot 03.
•
Path—identifies the device’s path; for the SCSI board, this is the same for both channels. In
this example, the HBA’s path is Acpi(HWP0002,200)/Pci(1|0) for channel A and
Acpi(HWP0002,200)/Pci(1|1) for channel B.
Using the SCSI board’s information from the example above, the pieces of information that,
combined, tell you this is a SCSI board are the following (shown in bold, for highlighting purposes):
00
40
01
00
0x1000
0x0021
03
Acpi(HWP0002,200)/Pci(1|0)
00
40
01
01
0x1000
0x0021
03
Acpi(HWP0002,200)/Pci(1|1)
Looking at all of the above information together, the vendor (0x1000) and device (0x0021) are the
IDs for a SCSI board. Of the devices with those IDs, this device has two channels (Fnc # of 00
immediately followed by Fnc # of 01). Also, this SCSI board has a numeric (non-XX) slot # (03, in
this example).
Step 2. Still at the EFI shell prompt, type this command to obtain the controller’s handle for the SCSI card:
devtree
A tree of all EFI-capable devices installed in the system is displayed. The output could look like
this:
Device Tree
Ctrl[02]
Ctrl[04] Acpi(HWP0002,0)
Ctrl[76] Acpi(HWP0002,0)/Pci(1|0)
Ctrl[77] Acpi(HWP0002,0)/Pci(1|1)
Ctrl[78] Acpi(HWP0002,0)/Pci(1|2)
Ctrl[79] Acpi(HWP0002,0)/Pci(2|0)
Ctrl[7B] Acpi(HWP0002,0)/Pci(2|0)/Ata(Primary,Master)
Ctrl[7A] Acpi(HWP0002,0)/Pci(3|0)
Ctrl[7C] Acpi(HWP0002,0)/Pci(3|0)/Mac(00306E1ECE06)
Ctrl[05] Acpi(HWP0002,100)
Ctrl[32] Acpi(HWP0002,100)/Pci(2|0)
Ctrl[33] Acpi(HWP0002,100)/Pci(2|0)/Mac(00306E1E9EFA)
Ctrl[7D] LSI Logic Ultra320 SCSI Controller
Ctrl[7E] LSI Logic Ultra320 SCSI Controller
Ctrl[06] Acpi(HWP0002,200)
Ctrl[82] LSI Logic Ultra160 SCSI Controller
Ctrl[83] LSI Logic Ultra160 SCSI Controller
Ctrl[07] Acpi(HWP0002,300)
Ctrl[91] LSI Logic Ultra160 SCSI Controller
Ctrl[92] LSI Logic Ultra160 SCSI Controller
Ctrl[08] Acpi(HWP0002,400)
Ctrl[93] Acpi(HWP0002,400)/Pci(1|0)
Ctrl[94] Acpi(HWP0002,400)/Pci(1|0)/Mac(0002B35BE064)
Ctrl[09] Acpi(HWP0002,600)
Specifying SCSI Parameters
51
Ctrl[95] LSI Logic Ultra160 SCSI Controller
Ctrl[0A] Acpi(HWP0002,700)
Ctrl[96] Acpi(HWP0002,700)/Pci(1|0)
Ctrl[97] Acpi(HWP0002,700)/Pci(1|1)
Ctrl[98] Acpi(HWP0002,700)/Pci(2|0)
In the above example, this SCSI board’s information is shown in bold, for highlighting purposes.
You can tell the information is for this SCSI board because the path on the first
line—Acpi(HWP0002,200)— is the HBA’s path from the information displayed by the info io
command. The next two lines are for the SCSI board’s two channels, one line for each channel (they
contain the SCSI board’s description [LSI Logic Ultra160 SCSI Controller]). Note the value shown for
Ctrl—82 and 83—at the beginning of each of those lines; this is the controller’s handle for that
channel. You need to know it for the next step.
NOTE
The controller’s handle values will change on every boot.
Step 3. Still at the EFI shell prompt, type this command to obtain the EFI driver’s handle for the SCSI
card:
drvcfg
A list of all EFI-capable configurable components in the system is displayed. The output may look
like this:
Drv[26]
Ctrl[79]
Lang[eng]
Drv[34]
Ctrl[83]
Lang[eng]
Drv[35]
Ctrl[82]
Lang[eng]
Drv[36]
Ctrl[92]
Lang[eng]
Drv[37]
Ctrl[91]
Lang[eng]
Drv[38]
Ctrl[95]
Lang[eng]
Drv[71]
Ctrl[7D]
Lang[eng]
Drv[71]
Ctrl[7E]
Lang[eng]
This listing shows which driver controls which device (controller). In the above example, this SCSI
board’s information is shown in bold, for highlighting purposes. You can tell the information is for
this SCSI board because the values shown for Ctrl—82 and 83—are the controller’s handles for the
SCSI board’s two channels (from the information displayed by the devtree command).
NOTE
The EFI driver’s handle values will change on every boot.
TIP
From this command (drvcfg), we recommend you record these two pieces of
information for each channel of each SCSI board HBA you want to change the SCSI
parameters for:
•
Drv (the EFI driver’s handle)
•
Ctrl (the controller’s handle)
Step 4. Using the information (the driver’s handle [Drv] and the controller’s handle [Ctrl]) from the
drvcfg command, start the EFI SCSI Setup Utility for one channel of this SCSI board. Still at the
EFI shell prompt, type this command:
drvcfg -s drvr_handle cntrl_handle
Specifying SCSI Parameters
52
where
•
drvr_handle is the handle of the driver that controls the channel whose SCSI ID you want to
display or change
•
cntrl_handle is the handle of the controller for the channel whose SCSI ID you want to
display or change
So, continuing the example for channel A of this SCSI board, you would type:
drvcfg -s 35 82
Step 5. The EFI SCSI Setup Utility starts and its main menu is displayed, showing a list of all the EFI
capable HBAs in the system.
TIP
To move the cursor in the EFI SCSI Setup Utility, you can use these keys:
•
Arrow keys: ↑ ↓ ← →
•
Alternate keys:
H = left
J = down
K = up
L = right
I = home
O = end
Move the cursor to highlight this channel of this SCSI board; press Enter. (To determine which
channel of the HBA to highlight, match the PCI Bus, PCI Dev, and PCI Func values on this screen
to the Bus #, Dev #, and Fnc # values from the info io command.)
CAUTION
Do not select the option on the main menu.
Step 6. The “Adapter Properties” screen for this channel of this SCSI board is displayed. If you like, you can
make sure the utility is running for this channel of this SCSI board by comparing the values shown
for PCI Bus, PCI Device, and PCI Function to the Bus #, Dev #, and Fnc # values from the
info io command.
CAUTION
Do not change the value for any of these fields on the “Adapter Properties” screen:
•
Auto Termination
•
SCSI Parity
•
SCSI Bus Scan Order
•
Spinup Delay (Secs)
Changing any of these fields can cause unpredictable results.
Specifying SCSI Parameters
53
CAUTION
Do not change the value for any of these fields on the “Device Properties” screen:
•
Scan Id
•
Scan LUNs > 0
•
Disconnect
•
SCSI Timeout
•
Queue Tags
•
Format
•
Verify
Changing any of these fields can cause unpredictable results.
Step 7. You may display (and optionally change) any SCSI parameters listed below for this channel of this
SCSI board, or restore its SCSI parameters to their default values.
•
SCSI ID
•
Maximum data transfer rate
•
Bus width
•
Whether the HBA is bootable (driver support)
•
Avoid bus resets (secondary cluster server)
•
Restore Defaults
Step 8. Use the arrow keys to navigate to the appropriate SCSI parameter.
Step 9. Use the plus (+) and minus (-) keys to scroll through the values until the value you want is
displayed.
Step 10. Press Esc to exit the “Adapter Properties” screen. You are given these choices:
•
Cancel the exit from the screen (to stay in the “Adapter Properties” screen for this channel of
this SCSI board)
•
Save the changes you made and then exit the screen
•
Discard the changes you made and then exit the screen
Step 11. Move the cursor to the action (cancel, save, or discard) you want to take; press Enter.
If you selected cancel, you remain in the “Adapter Properties” screen for this channel of this SCSI
board. You can still change this channel’s parameters listed above.
If you selected save or discard, you are placed in the EFI SCSI Setup Utility’s main menu.
CAUTION
Do not select the option on the main menu.
Step 12. Press Esc to exit the main menu and the EFI SCSI Setup Utility.
Specifying SCSI Parameters
54
Step 13. Select the option for exiting the utility.
Step 14. When you are prompted to, press Enter to stop this SCSI board; you are now back at the EFI shell
prompt.
Step 15. At the EFI shell prompt, type this command:
reset
The system starts to reboot. This is required to cause the new SCSI setting.
The management processor is an independent support system for the server. It provides a way for you to
connect to a server and perform administration or monitoring tasks for the server hardware.
The management processor controls power, reset, Transfer of Control (TOC) capabilities, provides console
access, displays and records system events, and can display detailed information about the various internal
subsystems. The management processor also provides a virtual front panel that can be used to monitor
system status and see the state of front panel LEDs. All MP functions are available via the LAN, local RS-232
and remote RS-232 ports.
The management processor is available whenever the system is connected to a power source, even if the
server main power switch is in the off position.
Access to the management processor can be restricted by user accounts. User accounts are password
protected and provide a specific level of access to the server and management processor commands.
Multiple users can interact with the management processor. From the MP Main Menu users can select any of
the following options: enter management processor command mode, enter console, view event logs, view
console history, display virtual front panel, enter console session, or connect to another management
processor. Multiple users can select different options from the MP Main Menu at the same time. However,
management processor command mode and console mode are mirrored, The MP allows only one user at a
time to have write access to the shared console.
Accessing the Management Processor
You can connect to the management processor using the following methods:
•
The local RS-232C port using a local terminal
•
The remote RS-232C port using external modem (dial-up) access, if remote modem access is configured
•
The management processor LAN port using Web Console or telnet if login access through the
management processor LAN is enabled
Interacting with the Management Processor
To interact with the management processor, perform the following steps:
Step 1. Log in using your management processor user account name and password.
NOTE
If the management processor is not displaying the MP Main Menu, use CTRL+B to
access the MP Main Menu and the management processor (MP) prompt.
Step 2. Use the management processor menus and commands as needed. A list of available commands can
be displayed by using the management processor help function (in the MP Main Menu, enter HE
followed by LI at the MP HELP: prompt). Log out using the X command (in the MP Main Menu,
enter X at the MP> prompt) when done.
Management Processor Command Interface
56
Management Processor Command Interface
Use the management processor menus and commands as needed. The login screen, which includes the Main
Menu, is shown below. Main Menu commands (CO, VFP, CM, CL, CSP, SE, SL, HE, and X) can be entered after the
MP prompt. Commands not displayed in the MP Main Menu can be accessed in command mode by first using
the CM command at the MP prompt. (A list of available commands can be displayed by using the management
processor help function. Display the list of commands as follows: in the MP Main Menu, enter HE after the MP>
prompt, then enter LI after the MP HELP: prompt.) You can return to the MP Main Menu by typing CTRL+B.
Figure 4-2
MP Welcome Screen
MP Login: Admin
MP password: *****
Hewlett-Packard Management Processor
(C) Copyright Hewlett-Packard Company 1999-2003. All rights reserved
System Name: xxxxxxxxx
MP MAIN MENU:
CO:Console
VFP:Virtual Front Panel
CM:Command Menu
CL:Console Log
SL:Show Event Logs
CSP:Connect to Service Processor
MP commands are described in the following paragraphs.
Management Processor Command Interface
57
Management Processor Commands
Table 4-3
Management Processor Commands and Descriptions
Command
Description
BP
Reset BMC passwords
CA
Configure asynch/serial ports
CG
Certificate generator
CL
View console log
CM
Select command mode
Ctrl+B
Return to MP main menu
CO
Select console mode
CSP
Connect to service processor
DATE
Date display
DC
Default configuration
DF
Display FRU information
DI
Disconnect remote or LAN console
FW
Upgrade MP firmware
HE
Display help for menu or command
ID
System information
IT
Inactivity timeout settings
LC
LAN configuration
LOC
Locator LED display and configuration
LS
LAN Status
MR
Modem reset
MS
Modem status
PC
Remote power control
PG
Paging parameter setup
PS
Power management module status
RB
Reset BMC
RS
Reset system through RST signal
SA
Set access
SE
Enter OS session
SL
Show event logs
Management Processor Command Interface
58
Reset BMC Passwords
BP: Reset BMC Passwords
This command resets BMC passwords (both USER and ADMIN passwords).
Configure Serial Port Parameters
CA: Configure local and remote serial port parameters
Set up the local serial port parameters as follows:
•
TERMINAL TYPE: Vt100 vs HPterm
•
BAUD RATES: Input and output data rates are the same; 300, 1200, 2400, 4800, 9600, 38400, 115200
bit/sec.
•
FLOW CONTROL: Hardware uses RTS/CTS; Software uses Xon/Xoff.
•
TRANSMIT CONFIGURATION STRINGS: Disable this setting whenever the modem being used is not
compatible with the supported modem (MT5634ZBA).
IMPORTANT
Do not mix HP and vt100 terminal types at the same time.
Set up the remote serial port parameters as follows:
•
MODEM PROTOCOL: Bell or CCITT (CCITT is a European standard; RTS/CTS signaling is used, as well
as the Ring signal. Bell is a U.S. or simple mode).
•
BAUD RATES: Input and output data rates are the same; 300, 1200, 2400, 4800, 9600, 38400, 115200
bit/sec.
•
FLOW CONTROL: Hardware uses RTS/CTS; Software uses Xon/Xoff.
SO
Security options
SS
System processor status
SYSREV
Current system firmware revisions
TC
Reset via transfer of control (TOC)
TE
Tell- send a message to other users
UC
User configuration
VFP
Virtual front panel
WHO
Display connected management processor users
X
Exit management processor and disconnect
XD
Diagnostics and/or reset of management processor
Table 4-3
Management Processor Commands and Descriptions (Continued)
Command
Description
Management Processor Command Interface
59
•
TRANSMIT CONFIGURATION STRINGS: Disable this setting whenever the modem being used is not
compatible with the supported modem (MT5634ZBA).
•
MODEM PRESENCE: When the modem may not always be connected, set this parameter to “not always
connected”.
For example: A modem attached through a switch. In mode “not always connected,” no dial-out functions
are allowed: DIAL-BACK is disabled, and PAGING is not possible.
The MP mirrors the system console to the MP local, remote/modem, and LAN ports. One console output
stream is reflected to all of the connected console users. If several different terminal types are used
simultaneously by the users, some users may see strange results.
Example 4-19
HP-UX
Applications that care about the terminal type (install, SAM, vi, and so on) running on HP-UX use three
methods to determine the terminal type:
1. The application takes the terminal information from the OS. This value is set in the CA command and
takes effect for all MP ports.
2. The $TERM shell environment variable.
3. The application directly queries the terminal (in this case, the write enabled terminal establishes the
terminal type).
Make sure that settings #1 and #2 agree with your terminal type.
Certificate Generate
CG: Generate RSA key pair or Self Signed Certificate
This command generates a new RSA key pair and self signed certificate.
Console Log
CL: Console Log—view the history of the Console output
This command displays up to 60 Kilobytes of logged console data (about 60 pages of display in text mode) sent
from the system to the Console path.
Command Mode
CM: Command Mode—enter command mode
This command switches the console terminal from the MP Main Menu to mirrored command interface mode.
If the current mux authority is administrator and the new login is as an operator, the command mux will be
denied (remains in MP Main Menu mode). If a command is in progress, a message will be displayed warning
the new user of system status.
Console
CO: COnsole—leave command mode and enter console mode
This command switches the console terminal from the MP Main Menu to mirrored/redirected console mode.
All mirrored data is displayed. Type CTRL+B to return to the MP command interface.
For VT100 and HPTERM, verify that the MP setting in the CA command is correct and all mirrored consoles
are of the same terminal type for proper operation.
Management Processor Command Interface
60
Connect to Service Processor
CSP: Connect to remote management processor over the LAN
This command allows the local or remote port user to connect over the MP LAN to another MP on the
network. The user that launches the command is given a private connection to the other MP over the LAN. To
return to the original MP, type CTRL+] to disconnect the CSP session.
Date
DATE: Displays the current date, as generated in the MP real-time clock.
Default Configuration
DC: Default Configuration—reset all MP parameters to the default configuration
This command sets all MP parameters back to their default values. The user may reset all or a subset of the
following parameters:
•
IP configurations
•
Modem configuration
•
Paging configuration
•
Command Interface configuration
•
Disable remote access, security configuration
•
Session configuration. For example: setting the security configuration to default erases all users and
passwords.
There are three ways to reset passwords in the MP:
1. In the SO command, change individual users.
2. In the DC command choose “Reset Security Configuration”.
3. Forgotten passwords can be reset by pressing the reset button on the back panel of your HP Server. See
Figure 2-7 on page 20. After the MP reboots, the local console terminal displays a message for five
seconds. Responding to this message in time will allow a local user to reset the passwords.
Notice that all user information (logins, passwords, and so on) is erased in methods 2 and 3.
Display FRUID
DF: Display FRUID information
This command displays FRUID information from the BMC for FRU devices. Information provided includes
serial number; part number; model designation; name and version number; and manufacturer.
Disconnect Remote or LAN Console
DI: DIsconnect remote/modem or LAN/WEB console
This command disconnects (hang up) the remote/modem or LAN/WEB users from MP. It does not disable the
ports. The remote console is no longer mirrored.
Management Processor Command Interface
61
Front Panel Process
FP: Turn off front panel fault or attention LEDs
This command allows the user to control the state of front panel fault and attention LEDs, individually or
together.
MP Firmware Update
FW: Activates MP firmware upgrade mode
This command is available from either the LAN or local serial port. This command activates firmware
upgrade mode, which loads new firmware through the MP LAN by FTP (which must be operational). An MP
Reset is generated after the upgrade is complete.
Help
HE: Display help for menu or command
This command displays the MP hardware and firmware version identity, and the date and time of firmware
generation. If executed from the MP Main Menu, general information about the MP, and those commands
displayed in the MP Main Menu, will be displayed. If executed in command mode, this command displays a
list of command interface commands available to the user. It also displays detailed help information in
response to a topic or command at the help prompt.
Display System ID
ID: Display/modify system information
This command allows the user to display and modify the following:
•
SNMP contact information
•
SNMP server information
•
SPU hostname
Inactivity Timeout
IT: Inactivity Timeout settings
The session inactivity timeout is up to 1,440 minutes—default is 60 minutes. This timeout prevents sessions
to the system from being inadvertently left open. A session can be started by the SE command. An open
session can prevent users from logging onto the MP through a port and can also prevent system applications
from initiating an outbound connection.
MP inactivity timeout is up to 1,440 minutes - default is 5 minutes. This timeout prevents a user from
inadvertently keeping the MP locked in a MP Command Interface mode preventing other users from looking
at the console output. The MP Command Interface inactivity. timeout may not be deactivated.
Flow control timeout is 0 to 60 minutes. If set to 0, no timeout is applied. This timeout prevents mirrored flow
control from blocking other ports when inactive.
Configure LAN Console
LC: LAN configuration (IP address, and so on)
This command displays and allows modification of the LAN configuration. Configurable parameters include:
Management Processor Command Interface
62
•
MP IP Address
•
MP Host Name
•
Subnet Mask
•
Gateway Address
•
Web Console port number
•
Link State
The MP Host Name set in this command is displayed at the MP command interface prompt. Typically the
DNS name for the LAN IP is entered.
This field can be programmed to any useful name or phrase. For clarity, it is useful to enter MP-on-SYSTEM as
the MP Host name, so both names show up in the prompt (limit 19 characters, no spaces allowed.) The web
access port number is also set by this command.
LAN Status
LS: LAN Status
This command displays all parameters and the current status of the MP LAN connections. The LAN
parameters are not modified by the execution of this command.
Return to Main Menu
MA: Return to MP Main Menu
This command makes the MP return to the nonmirrored MP Main Menu. This is the same as executing
CTRL+B.
Modem Reset
MR: Modem Reset
This command makes the MP send an AT Z command to the modem, which resets it. Any modem connections
are lost. The initialization results can be viewed via the MS command.
Modem Status
MS: Modem Status—Display modem status
The MS command displays the state of the modem lines connected to the remote/modem serial port. The
display can be updated by pressing Enter. The current state of the status signals DCD, CTS, DSR, RI and the
last state of the control signals DTR, RTS set by the firmware are displayed.
Power Control
PC: Power Control—turn system power on and off
For proper system shutdown, shutdown the OS before issuing this command or use the commands graceful
shutdown option.
This command allows you to switch the system power on or off. the user can have the action take place
immediately or after a specified delay.
Management Processor Command Interface
63
Notice this is roughly the equivalent to turning the system power off at the front panel switch. There is no
signal sent to the OS to bring the software down before power is turned off. To turn the system off properly.
you must ensure that the OS is in the proper shutdown state before issuing this command. Use the proper OS
commands or use the graceful shutdown option of the Remote Power Control command.
Configure Paging
PG: Paging parameter setup—configures pagers
This command allows the user to configure the pagers and set triggering events.
A string description of the triggering event will be sent with the page.
Power Status
PS: Power status—display the status of the power management module
This command displays on the console the status of the power management module.
Reset BMC
RB: Reset BMC
This command resets the BMC by toggling a GPIO pin.
Reset System
RS: Reset system through RST signal
IMPORTANT
Under normal operation, shut down the OS before issuing this command.
This command causes the system (except the MP) to be reset through the RST signal.
Execution of this command irrecoverably halts all system processing and I/O activity and restarts the
computer system. The effect of this command is very similar to cycling the system power. The OS is not
notified, no dump is taken on the way down, and so on.
Set Access
SA: Set access options—configures access for LAN and remote/modem ports
This command will disconnect modem, LAN, and web users if access is disabled.
Create Local Session
SE: Log into the system on local or remote port
Only valid from the local or remote/modem port, SE allows the user to leave the MP Command Interface and
enter a system session. Other mirrored MP users are placed in console mode. The session user returns to the
mirrored MP session on exit.
The MP regularly checks the activity of the session, closes the connection with the system, and, if the timeout
period has elapsed, returns the port to mirroring. The timeout period is set with the IT command. On HP-UX,
the SE command works on the local and remote ports.
Management Processor Command Interface
64
In HP-UX, use the System Administration Manager (SAM) to add modem device files for the session UARTS.
The modem type, CCITT or Bell must agree with the remote port settings for the remote session port and
always be Bell mode for the local session port.
If the system and the MP Command Interface local or remote ports have been configured with different port
speeds, the baud rate changes to the rate specified by the OS for the duration of the session.
Display Logs
SL: Display contents of the system status logs
This command displays the contents of the event logs that have been stored in nonvolatile memory.
•
System Event Log (SEL)—High attention events and errors
•
Forward progress—All events
•
Current boot log—All events between “start of boot” and “boot complete”
•
Previous boot log—The events from the previous boot
Reading the system event log turns off the attention LED. Accessing this log is the only way to turn off the
attention LED when it is flashing and alerts have not been acknowledged at the alert display level.
Events are encoded data that provide system information to the user. Some well-known names for similar
data would be Chassis Codes or Post Codes. Events are produced by intelligent hardware modules, the OS,
and system firmware. Use VFP to view the live events. Use SL to view the event log.
Navigate within the logs as follows:
•
+ — View the next block (forward in time)
•
- — View the previous block (backward in time)
•
Enter () — View the next block in the previously selected direction (forward or backward in time)
•
D — Dump the entire log for capture or analysis
•
F — First entry
•
L — Last entry
•
J — Jump to entry number __
•
V — View mode configuration (text, keyword, hex)
•
? — Display this help menu
•
Q — Quit
Table 4-4 defines alert (or severity) levels.
Table 4-4
Alert Levels
Severity
Definition
0
Minor forward progress
1
Major forward progress
2
Informational
3
Warning
Management Processor Command Interface
65
Security Options
SO: Configure security options and access control (users, passwords, and so on)
This command modifies the security parameters of the MP, which include login timeouts and allowed
password faults.
If configured, when you access the MP via the modem port, the MP hangs up and dials the user back. This
does not work if Modem Presence is set to not always connected with the CA command.
If the mode is single, the state is changed to disabled after the first login.
A disabled user’s login is not accepted.
Firmware Revision Status
SYSREV: Displays the revision status of firmware in the system processors
This command displays the revision status of firmware in the system processors.
System Status
SS: Displays the status of the system processors
The SS command displays the status of the system processors and which processor is the monarch.
Transfer Of Control
TC: System reset through INIT or TOC (Transfer of Control) signal
Under normal operation, shut down the OS before issuing this command.
This command causes the system to be reset through the INIT (or TOC) signal. Execution of this command
irrecoverably halts all system processing and I/O activity and restarts the computer system. It is different
from the RS command in that the processors are signaled to dump state on the way down.
Tell
TE: TEll—sends a message to other terminals
Up to 80 characters can be typed in. The message is broadcast to the other mirrored clients. Users in a session
or CSP are not shown the message.
User Configuration
UC: User Configuration—controls user access
This command allows an administrator to add, modify, re-enable, or delete user logins. The administrator can
also enable or disable security warnings and change passwords.
5
Critical
7
Fatal
Table 4-4
Alert Levels (Continued)
Severity
Definition
Management Processor Command Interface
66
Virtual Front Panel
VFP: Display Virtual Front Panel
When invoked, this command displays a current summary of system status, including the state of front panel
LEDs.
There are two ways that the live display of events can be started:
1. Live Mode: Invoked from the VFP command at the MP prompt. To exit, type Q to quit the console.
2. Early Boot Mode: When the boot sequence for the system begins, the live VFP is invoked automatically.
When boot finishes, you are automatically switched to console mode.
The LWED state reflects the state of the front panel LEDs. When system power is off, the remote LED shows
“off” even thought remote access may be enabled with the EL or ER commands.
Who
WHO: Displays a list of MP connected users
This command displays the login name and operating mode (Main Menu, command, and so on) of the
connected console client users, and the port on which they are connected. For the LAN and WEB console
clients the remote IP address is also displayed.
If the local console client user did not originate the MP command interface session, there is always one
default user listed for the local serial port: local user i. If the local console operator types CTRL+B, then the
login name that the local operator used is displayed instead.
Exit from MP
X: Exit from MP command interface and disconnect from the system
This command disconnects the executing user from the system. This command is available from the local
port.
Diagnostics
XD: Diagnostics and/or Reset of MP
This command allows the user to perform some simple checks to confirm the MP's health and its connectivity
status. The following tests are available:
•
MP Parameter Checksum
•
Verify I2C connection (get BMC Device ID)
•
LAN connectivity test using ping
•
Modem self-tests
Also, the MP can be reset from this command. A MP reset can be safely performed without affecting the
operation of the server.
Management Processor Help System
The MP has a robust help system. To invoke MP HELP, enter he after the MP> prompt. The following is
displayed:
Management Processor Command Interface
67
HE
==== MP Help: Main Menu ============================================(Administrator)===
Hardware Revision a1 Firmware Revision E.02.20 May 30 2003,15:18:47
MP Help System
Use Ctrl-B to exit MP command interface and return to the main MP menu:
Enter a command at the help prompt:
OVerview
: Launch the help overview
LIst
: Show the list of MP commands
: Enter the command name for help on individual command
TOPics
: Show all MP Help topics and commands
HElp
: Display this screen
Q
: Quit help
Enter one of the commands described above: OV, LI, , TOP, HE, Q
Before removing a cover to service components that cannot be hot-swapped, always
disconnect the AC power cords and unplug telephone cables. Disconnect telephone
cables to avoid exposure to shock hazard from telephone ringing voltages.
Disconnect the AC power cords to avoid exposure to high energy levels that may
cause burns when parts are short-circuited by metal objects such as tools or jewelry.
CAUTION
Do not operate the HP Server for more than 10 minutes with any cover (including power
supplies and disk drives) removed. Otherwise, damage to system components may result due to
improper cooling airflow.
However, you can safely remove a cover while the HP Server is running to remove and replace
PCI hot-plug boards. For any other service activity requiring access to the system board or
power distribution board, power-down the HP Server and observe all safety precautions.
Troubleshooting Methodology
Step 1. This is the entry point to the troubleshooting process. Here, you pick from a set of symptoms,
ranging from very simple (System LED is blinking) to the most difficult Machine Check Abort
(MCA) has occured. The following is a list of symptom examples:
•
System LED blinking
•
System Alert present on console
•
System will not power-up
•
System will not boot
•
Event/Error Message received
•
Machine Check Abort (MCA)
Step 2. This step narrows down the observed problem to the specific troubleshooting procedure required.
Here you isolate the failure to a specific part of the server so that you can perform more detailed
troubleshooting. For example:
•
Problem-System LED blinking
—
System Alert on console?
—
Analyze the alert by using the system event log (SEL) to identify the last error logged by
the baseboard management controller. Use either the EFI shell command line interface
(CLI) or the optional management processor card is installed, use the MP commands to
view the SEL.
Step 3. At this point you will have a good idea about which area of the system requires further analysis.
For example, if the symptom was “system will not power-up” then the initial troubleshooting
procedure may have indicated a problem with the DC power supply not coming up after the power
switch was turned on.
Step 4. You have now reached the point where the failed Field Replaceable Unit (FRU or FRUs) have been
identified and need to be replaced. You must now perform the specific remove-and-replace
verification steps.
NOTE
If multiple FRUs are identified as part of the solution, a fix cannot be guaranteed
unless all identified failed FRUs are replaced.
Step 5. There may be specific recovery procedures you need to perform to finish the repair. For example, if
the display panel is replaced, you will need to restore customer-specific information.
This section contains example HP Server problems and their possible solutions.
The system will not power-up.
Step 1. Review the installation procedures for the server. See the hp Integrity rx4640 Installation Guide.
Step 2. Check all power connection cables.
Step 3. Verify that 200-240 VAC power is available at the AC power receptacle. Check the receptacle output
with another device.
Step 4. Check the power supply fans to see if they are operating. The fans will operate off the DC voltage
generated by the power supply.
Step 5. Check that the Power LED on Front Control Panel is illuminated. See“Front Control Panel LEDs”
on page 74.
Step 6. Check all connections from the power supply to the power distribution module.
Step 7. Verify that all cables and modules are correctly connected. Especially check the display panel
connection.
Step 8. If the system starts to power-on and then power-off, a voltage rail of the power supply may be out of
specification. The BMC monitors voltages and prevents power-on when power values are out of
specification.
The system will not boot.
Step 1. Examine the front panel LEDs for warning or fault indications. The system LED will be flashing
yellow with a warning indication and flashing red with a fault indication. See “Front Control Panel
LEDs” on page 74.
Step 2. Examine the QuickFind Diagnostic Panel for indications of specific warning or fault indications.
The diagnostic LEDs present patterns that categorize the source of the warning or fault. See
“QuickFind Diagnostic Panel LEDs” on page 76.
Step 3. Display and examine the system event log (SEL) and forward progress log (FPL) for further
information relating to warning or fault isolation.
Step 4. Review the firmware revisions of all firmware.
Step 5. Use the MP command to cycle the system power: pc off, pc on.
Step 6. Turn the server off, wait at least twenty seconds, then turn the server back on to see if the failure
can be cleared.
Step 7. Check that all DIMMs are seated properly.
Step 8. Check that the DIMM configuration on the system board matches those approved. A minimum of
one DIMM pair must be installed.
Step 9. Verify that the DIMMs are fully seated. When the DIMM is fully seated in the mating connector,
the retaining latches are closed (they should be flush with the front of the DIMM). If the latches are
not closed, reseat the DIMM fully by engaging the retaining latches and closing them fully.
Step 10. Check that the processors are installed in the correct sockets and that each processor has a power
pod installed. Also verify that the processors are of the same type.
Step 11. Check the boot order with the SCSI configuration utility.
Step 12. If there are no obvious errors, reflash the BMC firmware, Refer to Chapter 4, “Utilities.”
Step 13. If the system will still not boot, it may be necessary to replace the base unit.
The system has intermittent failures
Step 1. Examine the front panel LEDs for warning or fault indications. The system LED will be flashing
yellow with a warning indication and flashing red with a fault indication. See “Front Control Panel
LEDs” on page 74.
Step 2. Examine the QuickFind Diagnostic Panel for indications of specific warning or fault indications.
The diagnostic LEDs present patterns that categorize the source of the warning or fault. See
“QuickFind Diagnostic Panel LEDs” on page 76.
Step 3. Display and examine the system event log (SEL) and forward progress log (FPL) for further
information relating to warning or fault indications.
Step 4. Make sure that the system fan assemblies are fully seated.
Step 5. Verify that the server is plugged into a power source that is within specifications described on the
label of the power supply.
Step 6. Make sure that the internal SCSI chain is terminated and that termination is not enabled on any of
the drives. Note that LVD SCSI termination is provided on the cable.
Step 7. Check that the processors are installed in the correct sockets and that terminators are installed in
all unused sockets.
Step 8. Reset the main memory DIMMs.
Step 9. If date and time or customer settings are being cleared, the system board battery may need to be
replaced.
The system LED or Diagnostic LEDs are not on and no error messages appear.
If the server does not work (with no LEDs illuminated) and no error messages appearing, check the following:
Step 1. Make sure that all cables and the AC power cord are plugged into their proper receptacles.
Step 2. Make sure that the AC outlet is working. If the server is plugged into a switched multiple-outlet
box, make sure that the switch on the outlet box is turned on.
Step 3. Make sure that the server is turned on (the power-on light should be green and the fans should be
on).
Step 4. Turn the server off, wait at least twenty seconds, then turn the server back on to see if the failure
can be cleared.
Step 5. Make sure that all boards are installed properly and the processors are installed in the correct slot.
They must be seated firmly in their slots and any cables must be connected firmly.
Step 6. If the server stopped working after you installed a new board, remove the board and turn on the
server. If your server now works, check the installation instructions received with the new board for
correct installation method. If the new board is preventing the server from powering on, it is likely
to have a serious electrical problem.
Step 7. If the server still does not work, remove all boards and options that you have installed (do not
remove the hard disk drives) and turn on the server.
Step 8. Add boards and options one at a time to determine which one is causing the problem.
Step 9. If you have added any memory, make sure that the DIMMs are seated properly in the board. Also
check the DIMM configuration, and that the DIMMs are matched pairs.
Power goes off on the server and does not come back on
When certain critical conditions exist, the server shuts down all power.
The critical conditions that may shut down the server are:
•
Critical temperature fluctuations or changes
•
Voltage problems (external AC line)
•
Power supply failure
If the server powers-off, and before you try a restart, do the following:
Step 1. Examine the front panel LEDs for warning or fault indications. The system LED will be flashing
yellow with a warning indication and flashing red with a fault indication. See “Front Control Panel
LEDs” on page 74.
Step 2. Examine the QuickFind Diagnostic Panel for indications of specific warning or fault indications.
The diagnostic LEDs present patterns that categorize the source of the warning or fault. See
“QuickFind Diagnostic Panel LEDs” on page 76.
Step 3. Check to make sure power is getting to the server. Plug a known working device into the power
outlet.
Step 4. Check for proper ventilation for the server. The server should have at least three inches of space
around the front and rear for proper airflow when installed in a rack.
NOTE
Temperature problems may be caused by a fluctuating power supply.
Step 5. Check the system specifications and make sure the environmental temperature and voltage are in
the specified guidelines.
Step 6. Monitor the system to make sure you are not experiencing further temperature and voltage
problems.
Troubleshooting Using LED Indicators
74
Troubleshooting Using LED Indicators
Your hp Integrity rx4640 Server has LED indicators located on the front control panel and an internal
QuickFind diagnostic panel that you can use to determine what repair action is required. For descriptions of
all LEDs on your hp Integrity rx4640 Server see the hp Integrity rx4640 Operations Guide on the
documentation CD included with your system.
Front Control Panel LEDs
The front control panel LEDs show you the system status at a glance. If warning or attention lights are
flashing, then you should to query the QuickFind diagnostic panel or management processor for further
information.
Figure 5-1
Front Control Panel
Table 5-1
Front Control Panel LED Definitions
LED/
Button
State
Flash Rate
Color
Description
System
Running
Steady
Green
Green: System normal-OS up and running
System
Booting
Flashing at
0.5Hz
Green
Flashing green: OS booting or at EFI
System
Attention
Flashing at
1 Hz
Yellow
Flashing yellow: warning-system needs
attention. Redundancy lost, component
failure pending.
System
Fault
Flashing at
2 Hz
Red
Flashing red: hard fault, system halted
System
Off
Off
N/A
Off: system off
Power
On
Steady
Green
Green: power normal
Power
On
Steady
Yellow
Flashing yellow: Housekeeping voltage
present
Power
Off
Off
Off
Off: Power off
Power LED
Thermal LED
TOC/NMI Button
Power Button
Disk LED
System LED
Locator
Button/LED
Troubleshooting Using LED Indicators
75
Disk LED
Flashing at
rate of disk
activity
Green
Flashing green: disk activity
Thermal
LED
OK
Steady
Green
Green: thermal OK
Thermal
LED
Warning
Flashing at
1 Hz
Yellow
Flashing yellow-thermal warning
Locator
LED/Button
Flashing at
1 Hz
Blue
Flashing blue: system locator LED may be
remotely or locally activated/deactivated
Table 5-1
Front Control Panel LED Definitions (Continued)
LED/
Button
State
Flash Rate
Color
Description
Troubleshooting Using LED Indicators
76
QuickFind Diagnostic Panel LEDs
The QuickFind diagnostic panel is located under the top cover and is attached to the top of the power supply
cage. The following definitions describe the status of the various LEDs and what is wrong with the indicated
component.
Table 5-2
QuickFind Diagnostic Panel LED Definitions
Item
LED 0
LED 1
LED 2
LED3
Details
Processor
Socket 0
Socket
1
Socket
2
Socket
3
If the System LED (on front panel) is in the
attention or fault state and the processor
LED is on, then the processor or voltage
regulator has failed—the processor module
in the specified socket needs to be replaced.
If the thermal LED is in the warning or
critical state and the processor LED is on,
then the processor exceeded the warning or
critical level.
Subsystem
CPU
board
Memory
board
I/O
board
n/a
A soldered voltage regulator has failed—the
specified board must be replaced.
I/O VRM
12 volt
5 volt
3 volt
n/a
A plug-in voltage regulator has
failed—specific VRM must be replaced.
CPU VRM
n/a
n/a
n/a
n/a
n/a
Fan Module
0
1
2
n/a
One or both fans in a fan module have
failed—the module must be replaced.
Fan 2 is in front of the power supplies.
Memory
Bank X (0-7)
DIMM
xA
DIMM
xB
DIMM
xC
DIMM
xD
The specified DIMM has failed—the DIMM
must be replaced.
If all the LEDs for a rank (0-7) are lit and
the memory config error LED is lit, then the
DIMMs in the specified rank are
mismatched—replace mismatched DIMM.
Check Power
Supply
n/a
n/a
n/a
One of the power supply or power supply
fans have failed—replace the power supply.
The faulty power supply LED (located on
Power supply) will be lit.
Memory
Config Error
n/a
n/a
n/a
The DIMMs in a rank are mismatched. All
the DIMMs in the specified rank (0-7) will
be lit.
Processor
Config Error
n/a
n/a
n/a
The processors are mismatched—replace
mismatched processor.
Missing
Component
n/a
n/a
n/a
A required component(s) is not installed in
the system and thus preventing “power-up.”
Troubleshooting Using LED Indicators
77
Figure 5-2
QuickFind Diagnostic Label
System
Temp
n/a
n/a
n/a
The internal temperature of the server has
exceeded the warning or critical level.
Check Event
Log
n/a
n/a
n/a
An event has occurred that requires
attention.
Table 5-2
QuickFind Diagnostic Panel LED Definitions (Continued)
Item
LED 0
LED 1
LED 2
LED3
Details
Troubleshooting Using LED Indicators
78
I/O Baseboard LED Indicators
Various LEDs, sensors, and reset or attention buttons are found on the I/O baseboard.
Figure 5-3
I/O Baseboard LEDs, Buttons and Sensors
Table 5-3
I/O Baseboard LEDs, Buttons and Sensors
LED/Button
Color
Status
Condition
12V VRM Power
LED
Green
On
12V VRM is functioning.
5V VRM Power
LED
Green
On
5V VRM is functioning.
PCI Attention
LED 6X
PCI Attention
Button (Doorbell)
6X
PCI Attention LED 6X
3.3VSB
Power
LED
12V VRM LED
3.3V VRM LED
5V VRM
LED
MP Heartbeat LED
Battery
BMC
Reset
Button
MP Soft
Reset
Button
MP Self-Test
LED
BMC Heartbeat LED
Locator Button/LED
PCI Power LED
6X
Troubleshooting Using Online Support Tools
79
Troubleshooting Using Online Support Tools
The following online support tools are available from the HP-UX environment.
Support Tools Manager
Support Tools Manager (STM) is available in three user interfaces:
•
Graphical interface for X-based terminals (XSTM)
•
Menu interface for ASCII terminals (MSTM)
•
Command line interface for all ASCII terminals (CSTM)
You can use the graphical and menu interfaces intuitively and you can use the command line interface to
drive STM using scripts.
You can use diagnostics to thoroughly test a device and isolate failures down to the suspected Field
Replaceable Unit (FRU).
To access the Support Tools Manager from a terminal console, perform the following steps:
Step 1. In a terminal window type the following at the command prompt:
fs0:\> cstm
The following message appears:
3.3V VRM Power
LED
Green
On
3.3V VRM is functioning.
MP Heartbeat
Green
Blinking
The management processor is functioning
correctly.
MP Self Test LED
Amber
On
Off
The management processor is executing the
internal self test.
The management processor has passed the
internal self test.
BMC Heartbeat
Green
Blinking
The baseboard management controller is
functioning correctly.
3.3VSB Power
LED
Green
On
Standby power is available.
MP Soft Reset
Button
N/A
Press
Resets the management processors values.
Table 5-3
I/O Baseboard LEDs, Buttons and Sensors (Continued)
LED/Button
Color
Status
Condition
Troubleshooting Using Online Support Tools
80
Support Tools Manager Version A.01.00
Type ‘help’ for a list of available commands
CSTM>
Step 2. To verify the system operation, type the following at the CSTM> prompt:
CSTM> verify all
Messages similar to the following appear:
Verification has started on device (CPU)
Verification has started on device (FPU)
CSTM> Verification of (FPU) has completed)
CSTM> Verification of (CPU) has completed)
Step 3. Press Enter to return to CSTM> prompt after all test results are reported.
Step 4. To exit the Support Tools Manager, type the following:
CSTM> exit
Event Monitoring Service
Event Monitoring Service (EMS) is the framework for monitoring hardware and reporting events. You can use
EMS to eliminate most undetected hardware failures that cause data loss or interruptions of system
operation. You can monitor a hardware device (such as a disk) for the occurrence of any unusual activity
(called an event). When an event occurs, it is reported by a variety of notification methods such as e-mail.
Event detections are handled automatically with minimal involvement on your part.
The following monitors are available:
•
IA-64 core hardware monitor
•
CMC monitor
•
UPS monitor
•
FC hub monitor
•
FC switch monitor
•
Peripheral status monitor
•
Memory monitor
EMS comes with your HP-UX operating system. To bring up the event monitoring main menu, execute the
following command at the shell prompt:
/etc/opt/resmon/lbin/monconfig
From the list of main menu selections, choose:
(E) Enable Monitoring
Instant Support Enterprise Edition (ISEE)
ISEE is a remote monitoring software package that can operate on your hp Integrity rx4640. It can deliver,
via the Internet, remote system monitoring and secure remote access from your machine to HP support
engineers. It places a MAP (script) on your machine that can be turned on by HP support to gather system
information. This software can be obtained at http://www.software.hp.com.
Troubleshooting Using Offline Support Tools
81
Troubleshooting Using Offline Support Tools
You can use offline support tools to troubleshoot your hp Integrity rx4640 Server.
•
Offline Diagnostic Environment (ODE)—available on IPF Offline Diagnostics on the resource CD that
comes with your HP Server.
•
e-Diagtools—available from IPF Offline Diagnostics on the resource CD that comes with your server.
NOTE
For machines using HP-UX the HP service partition is not available and the IPF Offline
Diagnostics CD must be used.
•
Management Processor (MP) event logs—available by logging on to the management processor via the
MP LAN or MP remote serial connectors.
Offline Diagnostic Environment (ODE)
ODE is used to evaluate specific hardware components via a command line interface. To access ODE from the
IPF Offline Diagnostics CD, perform the following steps:
Step 1. Power on your HP Server and insert the IPF Offline Diagnostics CD.
Step 2. Do not permit the server to boot into an operating system and at the EFI boot manager, select EFI
shell.
Step 3. Determine the file system that represents the CD and enter the appropriate command to access the
CD.
e-Diagtools
e-Diagtools is used to evaluate the hardware integrity of your HP Server. To access e-Diagtools from the IPF
Offline Diagnostics CD, perform the following steps:
Step 1. Power on your HP Server and insert the IPF Offline Diagnostics CD.
Step 2. Do not permit the server to boot into an operating system and at the EFI boot manager, select EFI
shell.
Step 3. Determine the file system that represents the CD and enter the appropriate command to access the
CD.
Step 4. After accessing the CD diagnostic menu, launch e-Diagtools for IPF and run the basic and
advanced tests according to the menus.
Figure 5-4
Offline Diagnostic Main Menu
***************************************************************************
******
******
******
Offline Diagnostic Environment
******
******
******
******
(C) Copyright Hewlett-Packard Co 1993-2003
******
Troubleshooting Using Offline Support Tools
82
******
All Rights Reserved
******
******
******
******
HP shall not be liable for any damages resulting from the
******
******
use of this program.
******
******
******
******
TC
Version B.00.10
******
******
SysLib Version B.00.06
******
******
Mapfile Version B.01.05
******
******
******
***************************************************************************
Type HELP for command information.
ODE> ls
Modules on this boot media are:
filename
type
size
created
description
-----------------------------------------------------------------------------
CIODIAG2.EFI
TM
642560
06/06/2003
Core IO diagnostic
CPUDIAG.EFI
TM
737280
06/06/2003
Processor diagnostic
IODIAG.EFI
TM
143872
06/06/2003
Runs selftests on I/O modules
MAPPER.EFI
TM
1653248
06/06/2003
System mapping utility
MEMDIAG.EFI
TM
263168
06/06/2003
Memory diagnostic
PERFVER.EFI
TM
814592
06/06/2003
Runs ROM-based selftests on peripherals
PLUTODIAG.EFI TM
514560
06/06/2003
SBA/LBA diagnostic
COPYUTIL.EFI
TM
1041920
06/06/2003
Disk-to-tape copy utility
DFDUTIL.EFI
TM
850432
06/06/2003
Disk firmware download utility
FCFUPDATE.EFI TM
608256
06/06/2003
FW Update Utility for Fibre Channel
ODE>
Management Processor (MP) Event Logs
The MP interface provides diagnostic and configuration capabilities. To access your MP interface, perform the
following steps:
NOTE
The MP interface must be accessed from a terminal console that is attached to the MP via the
MP LAN or MP remote serial connector.
Step 1. If necessary, press CTRL+B to access the MP interface.
Step 2. Log in with proper user name and password.
Troubleshooting Using Offline Support Tools
83
Step 3. Press cl to display the console logs. This log displays console history from oldest to newest.
Step 4. Press sl to display the system logs. The system logs consist of:
•
System event
•
Forward progress
•
Current boot
•
Previous boot
•
Live events
•
Clear SEL/FPL logs
Step 5. For a complete explanation of the management processor and all commands see Chapter 4,
“Utilities.”
Disk and I/O Path Logging
Some failures result in I/O path logging. These paths help to indicate the source of the error and may be
included in the error message or logged into console or event logs. The following table describes the disk drive
and PCI slot paths for your HP Server.
Other Event Logs and General Diagnostic Tools
This section describes other general diagnostic tools that will be provided for your HP Server and how to
generate other event logs for troubleshooting diagnosis.
Table 5-4
Disk and DVD Paths
Slot
Path
Slot 1
Acpi(HWP0002,100)/Pci(1|0)
Slot 2
Acpi(HWP0002,100)/Pci(1|1)
DVD
Acpi(HWP0002,0)/Pci(3|0)
Table 5-5
I/O Paths
I/O Slot
Path
Slot 1
Acpi(HWP0002,100)/Pci(2|0)
Slot 2
Acpi(HWP0002,100)/Pci(1|0)
Slot 3
Acpi(HWP0002,400)/Pci(2|0)
Slot 4
Acpi(HWP0002,400)/Pci(1|0)
Slot 5
Acpi(HWP0002,500)/Pci(2|0)
Slot 6
Acpi(HWP0002,500)/Pci(1|0)
Slot 7
Acpi(HWP0002,200)/Pci(1|0)
Slot 8
Acpi(HWP0002,600)/Pci(1|0)
Troubleshooting Using Offline Support Tools
84
•
General diagnostic tools available to support your HP Server are:
—
MCA analyzer
•
Event logs not generated by the management processor include:
—
Machine check abort log (MCA)
—
Corrected machine check log (CMC)
—
Corrected platform error log (CPE)
To access these logs type in at the shell>command line prompt:
errdump mca
errdump cmc
errdump cpe
This chapter provides the power requirements, operating conditions (environmental requirements), physical
requirements, hardware specifications, and video resolutions of the hp Integrity rx4640. The following tables
provide the specifications required for normal operation of the hp Integrity rx4640.
NOTE
The specifications and requirements for the power supply and environment can vary if you
install a mass storage device in the server that has more stringent environmental limits than
required for the HP Server. Ensure that the operating environment for any mass storage
devices you intend to install are compatible with the server environmental requirements.
Hardware Specifications
Table 6-1
Hardware Specifications
Micro-processors
Intel Itanium (up to 4 processors):
1.1 GHz dual processor module 32MB Level 4 cache. Up to 4 modules or 8
processors
1.3 GHz/3MB
1.5 GHz/6MB
Memory
Supports up to eight Double Data Rate (DDR) registered ECC Memory, in PC1600
DIMMs. Supported DDR DIMM sizes: 128MB, 256MB, 513MB, 1GB, and 2GB.
Requires DIMMs to be added in quads of equal capacity.
Video
Embedded
SCSI
Integrated Ultra-3 SCSI dual channel controller; 80 MB/s transfer rate with two
68-pin connectors.
integrated hp raid
controller
Optional.
LAN
PCI Gigabit, Fast Ethernet Controller; with Wake-on-LAN enabled/disabled via
BIOS setup.
PCI Slots
Four 64-bit PCI slots, 66MHz slots
Two 64-bit PCI-X slots, 133 MHz slots.
Core I/O
Three serial ports, 2 USB ports, Integrated RJ-45 LAN .
DVD-ROM
DVD-R/CD-ROM drive; IDE interface; 48x speed.
Mass Storage
Maximum Internal Storage: Two 73MB, 15K drive.
External Storage
2 external SCSI ports
1+1 configuration, redundant 200-240 VAC power supply (optional).
Table 6-1
Hardware Specifications (Continued)
Dimensions and Weights
87
Dimensions and Weights
This section provides dimensions and weights of hp Integrity rx4640 Server components.
Server Component Dimensions
Table 6-2
Server Component Dimensions
Dimension
Value
Height
6.87 in. (17.46 cm)
Width
17.32 in. (44 cm)
Depth
27.1 in. (68.8 cm)
Weight
Unloaded 75 lbs (34 kg)
Fully loaded <95 lbs (43 kg)
slot number, determining with info command, 50
B
Boot
EFI boot manager, 33
C
commands
devtree
controller handle, determining, 51
EFI-capable devices and controller handles,
displaying, 50
drvcfg
EFI configurable components, displaying, 51
EFI driver handle, determining, 51
EFI SCSI Setup Utility, starting, 51
info
adapter slot number, determining, 50
adapter’s path, determining, 50
configurable components, EFI capable, displaying, 51
controller handle, determining, 51
D
devtree command
controller handle, determining, 51
EFI-capable devices and controller handles,
displaying, 50
Dimensions
hp Integrity rx4640, 87
drvcfg command
EFI configurable components, displaying, 51
EFI driver handle, determining, 51
EFI SCSI Setup Utility, starting, 51
dump capture, 16
E
E-Diag Tools, 81
EFI
capable devices
and controller handles, displaying, 50
configurable components, displaying, 51
driver handle, determining, 51
EFI SCSI Setup Utility
starting, 51
Event logs
CMC, 83
CPE, 83
Management processor, 82
MCA, 83
Event Monitoring Service, EMS, 80
Extensible Firmware Interface
commands, 34
Extensible Firmware Interface, EFI, 33
G
Gigabit Ethernet card LAN LEDs, 25
H
handle
controller, determining, 51
Hot-Plug disk drives
LEDs, 16
I
info command
adapter path, determining, 50
adapter slot number, determining, 50
Instant Support Enterprise Edition, ISEE, 80
L
LEDs
Control Panel, 15
DVD, activity, 17
locations and functions, 13
Power supply status, 23
M
Management processor
accessing, 55
commands, 56
LEDs, 24
N
NMI Button, 16
O
Offline Diagnostic Environment, ODE, 81
P
path, determining for adapter
with info command, 50
Pinouts
Connector, 27
LAN, 30
SCSI Port, 31
Power Button, Main, 16
Q
QuickFind Diagnostic Panel
LEDs, 17
S
SCSI
setup utility, 49
specifying parameters, 49
SCSI adapter
path
determining with info command, 50
slot number of adapter, determining with info
command, 50
Specifications
dimensions and weights, 87
Hardware, 85
Support Tools Manager, 79
System I/O board
LEDs, 20
T
Troubleshooting
Online Support Tools, 79
system I/O board, 78