JetNet 3008 / 3008f Series

www.korenix.com Quick Installation Guide Industrial Ethernet Switch

JetNet 3008/3008f Industrial Ethernet Switch, conforming IEEE 802.3 and 802.3u standard,

supports 8 10/100Base TX (JetNet 3008) or 6 10/100TX plus two 100FX Fast Ethernet fiber ports in either multi-mode type (JetNet 3008f-m) or single-mode type (JetNet 3008f-s). The JetNet3008/3008f adopts rugged metal case design to operate in harsh environments (-25oC~70oC); It also provides IP-30 standard protection. It features one relay output to alarm users if a port link fails or with the power fails. Alarms can be enabled/disabled by a 9-pin dip switch. JetNet 3008/3008f is recommended to be powered by DC 24V with 12~48V range from the 6-pin removable terminal block. Introduction Box contents � JetNet 3008/3008f Switch � Quick Installation Guide � CD User Manual Mounting the Unit � Din-Rail mount: Mount the din-rail clip screwed on the rear of JetNet 3008/3008f on the DIN rail. About the DIN Rail installation, please refer user’s manual. Grounding JetNet 3008 / 3008f Switch There is one grounding screw on the bottom side of JetNet 3008/3008f. Connect the earth ground screw of switch to the grounding surface to ensure safety and prevent noise. See, Figure-1 Package contents Check List PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Figure-1

Wiring the Power Inputs

1. Insert the positive and negative wires into the V+ and V- contact on the terminal block connector. 2. Tighten the wire-clamp screws to prevent the DC wires from being loosened. See Figure-2 Notes: The recommended working voltage is DC24V (DC12~ 48V). The relay output alarm contacts are in the middle of the terminal block connector as shown in the figure below. By inserting the wires and set the DIP switch of the respective Port Alarm to “ON”, relay output alarm will detect any port failures, and form a short circuit. The alarm relay output is “Normal Open”. See, Figure -3. Wiring the Earth Ground In an industrial environment, there might have a lot of devices that generate electromagnetic noise, such as AC motors, electric welding machine, power generator. These devices will generate electric noise or surges that might disturb communications. To prevent those noises, the switch should be well earthed. In the figure- shows how to make connection. See, Figure -4. Wiring the Relay Output Maximum 1A current / DC 24V Figure-3 PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Figure-4 Figure-2

Connecting to Network

1. Connecting the Ethernet Ports: Connect one end of an Ethernet cable into the UTP port of JetNet 3008/3008f, while the other end is connected to the attached networking device. All UTP ports support auto MDI/MDIX function. The Speed LED will turn on for 100M link and turn off for 10Mbps link, the LNK/ACT LED will turn on for link up and blinking for packet transmit and receive. The fiber port only support 1 LED for Link and Activity. 2. Connecting the Fiber Port (JetNet 3008f) : Connect the fiber port on your JetNet 3008f to another Fiber Ethernet device, by following the figure below. Wrong connection will cause the fiber port not working properly. Korenix Customer Service KoreCARE is Korenix Technology’s global service center, where our professional staff are ready to solve your problems at any time Korenix global service center’s e-mail is [email protected] DIP Switch Settings for Alarm Relay Output � This is a Class 1 Laser/LED product. Don't stare into the Laser/LED Beam. ATTENTION RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # Status Description ON To enable port link down alarm at this port. ON To enable power failure alarm. Off To disable port link down alarm at this port. Off To disable power failure alarm.

JetNet 3008/3008f �����������IEEE 802.3�802.3u�����8�10/100Base

TX��(JetNet 3008)�6�10/100TX���2�100FX ����������������� (JetNet 3008f-m)�������(JetNet 3008f-s)���JetNet 3008/3008f �������� ��������������������(-25~70 oC)�������IP31������� �������������������/���������������������� ���������Dip����������JetNet 3008/3008f ������������ ������������12~48V ��������24V��������� �� �� � JetNet 3008/3008f ��� � ������ � ����CD� ���� � ���������������JetNet 3008/3008f ���������������� ������������������ JetNet 3008 / 3008f ���� �JetNet 3008/3008f�������������� ���������������������� ���������-1 ������ PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural �-1

�V+ �V- ���

2. ��������DC������������-2 ��������(DC12~ 48V)�����DC24V� ���������������������� ��� �������� ������������DIP�����“ON”� ���������������������� ���������������������� ������-3. ���� ��������������������� ��������������������� ��������������������� ��������������������� ����4��������� ���� 1. �������UTP��������JetNet 3008/3008f��������������� ��������UTP�������MDI/MDIX���100M������LED������ ���10M�����������LNK/ACT LED������������������� ��������������LED�������������������� ��������� Maximum 1A current / DC 24V PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural �-2 �-3 �-4

2. ����(JetNet 3008f) : ��������JetNet 3008f ���������������

����������������������� Korenix ���� KoreCARE����������������������������������� Korenix����������������[email protected] DIP ������ � ����Class 1 ��/LED ��� ��������� �� RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # �� �� ON ������������ ON �������� Off ������������ Off ��������

JetNet 3008/3008f �����������IEEE 802.3�802.3u�����8�10/100Base

TX�(JetNet 3008)�6�10/100TX��2�100FX ������������������� (JetNet 3008f-m)��������(JetNet 3008f-s)���JetNet 3008/3008f ������� ���������������������(-25~70 OC)�������IP31������ ��������������������/��������������������� ����������Dip止���������JetNet 3008/3008f ����������� �������������12~48V ��������24V��������� �� �� � JetNet 3008/3008f ��� � ������ � ����CD ���� � ���������������JetNet 3008/3008f ���������������� ������������������ JetNet 3008 / 3008f ���� �JetNet 3008/3008f�������������� ���������������������� ����������� ������ PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural �-1

�V+ �V- ���

2. ��������DC������������-2 ��: ����(DC12~ 48V)�����DC24V� ��������������������� ������������ ��������������������“ON”� ���������������������� ���������������������� ������-3� ���� ���������������������� ��������������������� ���������������������� ��������������������� �4��������� ���� 1. �������UTP��������JetNet 3008/3008f��������������� ��������UTP����MDI/MDIX���100M������LED��������� 10M�����������LNK/ACT LED���������������������� ������������LED�������������������� ��������� Maximum 1A current / DC 24V PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural �-2 �-3 �-4

2. �����(JetNet 3008f) : ��������JetNet 3008f ��������������

��������������������������� Korenix ���� KoreCARE���������������������������������� Korenix���������������[email protected] DIP ������ � ����Class 1 ��/LED ��� ��������� �� RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # �� �� ON ������������ ON �������� Off ������������ Off ��������

Die JetNet 3008/3008f Industrial Ethernet Switches entsprechen dem IEEE 802.3 und 802.3u

Standard. Sie bieten 8 x 10/100Base TX (JetNet 3008) oder 6 x 10/100TX + 2 x 100FX Fast Ethernet LWL-Anschlüsse (JetNet 3008f), entweder als Multi-Mode Typ (JetNet 3008f-m) oder Single-Mode Typ (JetNet 3008f-s). Der JetNet 3008/3008f bietet ein robustes Metallgehäuse (IP-30) für den Betrieb in einer rauen Umgebung (-25~70 OC). Wenn die Versorgungsspannung oder ein Port ausfällt, wird über einen Relaisausgang ein Alarm ausgegeben. Dieser Alarm kann über DIP-Schalter ein- oder ausgeschaltet werden. Als Versorgungsspannung sind 12~48VDC erforderlich. Empfohlen werden 24VDC, die an einem 6-PIN abnehmbaren Schraubklemmbock angeschlossen werden. Einführung Die Lieferung besteht aus � JetNet 3008/3008f Switch � Quick Installation Guide � CD mit Handbuch Montageanleitung � Hutschienenmontage: Haken Sie den auf der Rückseite des JetNet 3008/3008f befindlichen Hutschienen-Clip auf der Hutschiene ein. Weitere Informationen zur Hutschienenmontage entnehmen Sie bitte dem Handbuch Erdung des JetNet 3008 / 3008f Switches An der Unterseite des JetNet 3008/3008f befindet sich die Erdungs-Schraube. Verbinden Sie den Switch mit einem geeigneten Erdanschluss. Abbildung 1 Packungsinhalt PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Abbildung 1

Anschluss der Spannungsversorgung

1. Verschrauben Sie Leitungen der Netzteile gemäß nebenstehender Abbildung. Abbildung 2 2. Achten Sie darauf, die Schrauben fest anzuziehen. Hinweis: Versorgungsspannung beträgt DC24V (DC12~ 48V). Der Relaisausgang für den Alarm befindet sich in der Mitte der Steckerleiste (siehe Skizze). Bei angeschlossener Leitung und über DIP-Schalter aktiviertem Alarm, reagiert er auf Unterbrechungen bei den Ports und der Versorgungsspannung. Die Werkseinstellung ist „Alarm Aus“. Abbildung 3. Anschluss der Erde Im industriellen Umfeld können eine Menge an EMV-Störungen auftreten. Diese können von Wechselstrommotoren, E-Schweißautomaten oder Generatoren stammen. Solche Geräte erzeugen EMV-Störungen oder Spannungsspitzen, die unter Umständen die Kommunikation stören können. Zum Schutz vor solchen Störungen, sollte der Switch geerdet werden. Abbildung 4 Verdrahtung des Relaisausgangs Maximum 1A current / DC 24V PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Abbildung 2 Abbildung 3 Abbildung 4

Anschluss an das Netzwerk

1. Anschluss des Ethernet Ports: Stecken Sie den RJ-45 Stecker des einen Endes des Ethernetkabels in den UTP Port des JetNet 3008 / 3008f, und verbinden Sie das andere Ende des Kabels mit dem entsprechenden Netzwerk-Gerät. Alle UTP Ports unterstützen Auto MDI/MDIX. Die Geschwindigkeits-LED leuchtet bei einer 100M Verbindung und ist bei einer 10Mbps Verbindung aus. Die LNK/ACT LED leuchtet bei einer funktionierenden Verbindung und blinkt beim Empfang oder Versand von Datenpaketen. Der LWL Port unterstützt nur 1 LED für Link and Activity. 2. Anschluss des LWL Ports (JetNet 3008f) : Verbinden Sie den LWL-Port Ihres JetNet 3008f mit dem anderen LWL-Gerät. Beachten Sie dabei nebenstehende Abbildung Ein falscher Anschluss des LWL führt zu einer fehlerhaften Verbindung. Korenix Kundenservice KoreCARE ist ein weltweites Korenix Technology’s Servicecenter, wo Ihnen zu jeder Zeit fachkundige Mitarbeiter bei der Lösung Ihrer Probleme behilflich sind. Die Email-Adresse des Korenix Global Service Center lautet [email protected]. DIP Schalter-Stellung für den Relais-Alarmausgang � Dies ist ein Class 1 Laser/LED Produkt. Nicht in den Laser/LED Strahl schauen ATTENTION RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # Status Beschreibung ON Alarm “Ein” bei Verbindungsverlust auf diesem Port ON Alarm “Ein” bei Unterbrechung der Spannungsversorgung Off Alarm “Aus” bei Verbindungsverlust auf diesem Port Off Alarm “Aus” bei Unterbrechung der Spannungsversorgung

Les switchs Industriels Ethernet JetNet 3008/3008f sont conformes aux normes IEEE 802.3

et 802.3u. Ils proposent 8 ports 10/100Base TX (JetNet 3008) ou 6 ports 10/100TX plus 2 ports 100FX Fibre Ethernet Rapide en multi-mode type (JetNet 3008f-m) ou single-mode type (JetNet 3008f-s). Les JetNet 3008/3008f sont intégrés dans un Boitier métallique pour supporter les environnements industriels et ils peuvent fonctionner dans une plage de température de (-25~70oC. Ils proposent aussi en standard une protection IP-30. Une alarme par relais permet d’alerter les utilisateurs dans le cas de défauts de communication ou d’alimentation. Les alarmes peuvent être désactivées par dip switch. L’alimentation des 3008/ 3008f est de 24V DC avec une plage de 12 à 48V et une connectique par bornier amovible. Introduction � Switch JetNet 3008/3008f � Guide Installation Rapide � CD Manuel Utilisateur Montage du Switch � Montage duRail-Din: Monter le Rail-Din par les vis de fixation à l’arrière du Jetnet, ensuite vous pouvez clipser l’unité sur le Rail. Au sujet de l'installation du Rail-Din, vous pouvez faire référence au manuel d'utilisateur. Raccordement à la Masse du JetNet3008 / 3008f Il y a une vis sur le côté inférieur du switch qui permet le raccordement à la masse pour assurer la sécurité et prévenir des problèmes de bruit électromagnétique. Voir, Figure-1 Liste du Package PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Figure-1

Cablâge de l’alimentation

1. Insérer les fils d’alimentation dans les bornes positive (V+) et négative (V-) du bornier de raccordement. 2. Serrez les vis pour bloquer les fils. Voir Figure-2 Note: Il est recommandé d’utiliser une tension de 24V DC(DC12~ 48V). Le contact d’alarme du relais est positionné au milieu du bornier de raccordement comme le montre le croquis ci-dessous. Raccordez les fils et placer le switch correspondant sur ON. Une alarme se produira sur chaque défaut et le contact sera actionné. L’état du contact est " Normale Ouvert ". Voir Figure-3. Cablâge de la Masse Dans un environnement industriel, beaucoup d’appareils peuvent produire un bruit électromagnétique, tel que moteurs AC, poste de soudure, générateur d’alimentation. Ces appareils produisent un bruit important qui peut perturber les communications. Pour prévenir ces problèmes, le switch doit être raccordé à la masse. Sur la figure 4, vous verrez comment réaliser cette connexion. Cablâge du relais de sortie Maximum 1A current / DC 24V Figure-3 PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Figure-4 Figure-2

Raccordement au réseau

1. Connexion des ports Ethernet : Connectez une extrémité Ethernet sur le port UTP du JetNet 3008/3008f, et l’autre sur le périphérique attaché au réseau. Tous les ports UTP supportent la fonction auto MDI/MDIX. Un voyant Led sera allumé si la vitesse du lien est de 100 Mb et sera éteint pour 10 Mb, le voyant LNK/ACT LED sera allumé pour signaler un lien actif et clignotera pendant les transmissions et réceptions de paquets. Seul le port fibre possède un voyant LED pour le lien et pour la signalisation de l’activité. 2. Connexion du Port fibre (JetNet 3008f) : Connectez le port fibre sur le JetNet 3008f et l’autre extrémité à un périphérique Ethernet fibre, suivant l’image ci-dessous. Une mauvaise connexion entrainera une communication défectueuse du port fibre. � This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam. ATTENTION RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B DIP Switch Paramétrage Relais de sortie d’Alarme Service après vente Korenix KoreCARE est le service central de Korenix Technology’s, ou des professionnels sont prêt à résoudre vos problèmes à tout moment. Adresse e-mail du Centre de service Korenix : [email protected] P1 to P8 (Pin1 ~ 8) P9 Pin No. # Status Description ON Mise en fonction Alarme port de Communication ON Mise en Fonction Alarme d’Alimentation Off Mise hors fonction Alarme port de Communication Off Mise hors fonction du défaut d’Alimentation

El switch ethernet industrial JetNet3008/3008f, conforme a los estándar IEEE 802.3 y 802.3u,

soporta 8 puertos 10/100 Base TX (JetNet 3008) o 6 puertos 10/100TX mas dos 100FX en fibra multimodo (JetNet 3008f-m) o monomodo (JetNet 3008f-s). Incorpora un robusto chasis metálico que posibilita temperaturas de trabajo extremas (-20º a 70º) al tiempo que ofrece protección IP-30. Dispone de una salida por relé para alertar al usuario ante posibles fallos en el link de un puerto o de alimentación. Dichas alarmas pueden ser habilitadas mediante un DIP-switch de 9 pins. Para el JetNet 3008/3008f se recomienda una alimentación de 24V DC, siendo su rango admisible entre 12 y 48V. Dicha alimentación se suministra a través de un terminal removible de 6 pins. Introducción La caja contiene � Switch JetNet 3008 / 3008f � Guía de instalación rápida � Manual de usuario en CD Montaje de la unidad � Montaje en carril DIN: Ajustar en el carril DIN el clip instalado en la parte trasera del JetNet 3008/3008f Para instalación en el carril DIN, por favor consulte el manual de usuario Conexión a tierra del JetNet 3008 / 3008f Existe un tornillo de conexión a tierra en la parte trasera del JetNet 3008/3008f. Utilice este tornillo para unir el chasis a tierra por motivos de seguridad y para prevenir ruido. Ver Fig. 1. Contenido del embalaje PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Fig. 1

Conexión de la alimentación

1. Inserte las líneas positivo y negativo en los terminales V+ y V- del conector de entrada. 2. Ajuste los tornillos del terminal para asegurar la conexión (Ver Fig. 2) Nota: El voltaje recomendado de trabajo es 24VDC (12-48 VDC) Los contactos de la salida de alarma por relé se encuentran en la parte central del bloque de conexión, tal como se muestra en la figura. Realizando las conexiones indicadas y configurando el DIP Switch del puerto respectivo a ON, el relé conectará sus terminales de salida ante cualquier fallo en el puerto. La salida por relé es del tipo “Normalmente Abierto” (Ver Fig. 3) Conexión a Tierra En un entorno industrial puede haber muchos dispositivos que generen ruido electromagnético, como por ejemplo motores AC, maquinas de soldadura eléctrica o generadores de corriente. Este ruido eléctrico o picos de tensión pueden afectar a las comunicaciones. Para prevenir esos efectos, el switch debería estar correctamente conectado a tierra, tal como muestra la figura 4. Cableado de la salida por relé Maximum 1A current / DC 24V Fig. 3 PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Fig. 4 Fig. 2

Conexión a la red

1. Conectando los puertos ethernet: Conectar un extremo del cable ethernet al puerto UTP del JetNet 3008/3008f y el otro al dispositivo a conectar a la red. Todos los puertos UTP soportan la función auto MDI/MDIX. El led Speed se iluminará para conexiones a 100M y permanecerá apagado para enlaces a 10M, el led LNK/ACT se ilumina al establecer el enlace y parpadea con el envío y recepción de datos. El puerto de fibra dispone de un único led para el enlace y la actividad del puerto. 2. Conectando los puertos de fibra (JetNet 3008f) : Conectar los puertos de fibra del JetNet 3008f a otro dispositivo ethernet siguiendo el esquema de la figura adjunta. Una conexión errónea provocará un funcionamiento incorrecto en el puerto óptico. Servicio Técnico Korenix KoreCARE es el centro de servicio global de Korenix, donde nuestros profesionales se encuentran disponibles para resolver sus problemas en cualquier momento. La dirección de correo electrónico del servicio es [email protected]. Configuración del DIP-switch para la salida de alarma por relé � Esto es un dispositivo Láser/Led clase 1. No mire fijamente el haz Láser/Led ATTENTION RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # Estado Descripción ON Habilita alarma por pérdida de link en ese Puerto. ON Habilita alarma por fallo en alimentación. Off Deshabilita alarma por pérdida de link en ese Puerto. Off Deshabilita alarma por fallo en alimentación.

Lo Switch Industriale Ethernet JetNet 3008/3008f , conforme agli standard IEEE 802.3 e

802.3u, supporta 8 porte 10/100Base TX (JetNet 3008) o 6 porte 10/100TX più due porte fibra Fast Ethernet 100FX, sia monomodale (JetNet 3008f-s) che multimodale (JetNet 3008f-m). Lo chassis del JetNet 3008/3008f è realizzato in metallo resistente per operare in condizioni ambientali difficili (-25~70oC); prevede inoltre la protezione standard IP-30. E’ caratterizzato da una uscita a relè che avvisa l’utente di eventuali interruzioni del collegamento ad una porta o all’alimentazione. L’allarme può essere abilitato o disabilitato con un DIP– switch. E’ consigliabile alimentare il JetNet 3008/3008f a 24VDC con range 12~48V dalla morsettiera rimovibile a 6 pin. Introduzione La confezione contiene: � JetNet 3008 / 3008f Switch � Guida rapida � CD Manuale Utente Montaggio dell’unità � Montaggio su guida Din: Montate la clip avvitata sul retro del JetNet 3008/3008 sulla guida Din. A proposito dell’installazione della guida Din, riferirsi al manuale utente. Messa a terra JetNet 3008 / 3008f Switch C’è una vite per messa a terra nel lato sottostante del JetNet 3008/3008f. Connettere questa vite dello switch con il terreno per operare in sicurezza e prevenire disturbi. Vedi fig. 1 Contenuto dell’imballo. PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural fig.1

1. Inserire i cavi positivo e negativo nel contatto

V+ e V- sul connettore della morsettiera. 2. Stringere le viti del morsetto per evitare lo scollegamento dei cavi DC. Vedi fig.2 Note: La tensione operativa raccomandata è 24 Vdc (DC12~ 48V). I contatti di allarme si trovano nella morsettiera come mostrato nella figura sotto. Inserendo i cavi e settando il DIP– switch della rispettiva porta di allarme su “ON”, il contatto di allarme controllerà ogni porta prevenendo guasti e corto circuiti. L’uscita relè del contatto di allarme è “Normalmente Aperta” vedi fig. 3 Cablaggio a terra In un contesto industriale, si trovano molti dispositivi che generano disturbi elettromagnetici, come i motori AC, saldatrici elettriche, generatori. Questi dispositivi generano disturbi o sovraccarichi che potrebbero disturbare le comunicazioni. Per prevenire queste problematiche, è necessaria la messa a terra. Vedi fig.4 per effettuare la connessione. Cablaggio uscita a relè Maximum 1A current / DC 24V fig. 3 fig. 4 PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural fig. 2

Connessione alla Rete

1. Connessione delle porte Ethernet: Connettere una estremità del cavo Ethernet nella porta UTP del JetNet 3008/3008f, mentre l’altra estremità è connessa con il dispositivo di rete collegato. Tutte le porte UTP supportano la funzione auto MDI/MDIX. Il LED di velocità si accenderà per il collegamento 100M e si spegnerà per il collegamento 10Mbps. Il LED di LNK/ACT si accenderà per il collegamento e lampeggerà per il pacchetto trasmesso e ricevuto. La versione fibra supporta soltanto 1 LED per il collegamento e l’attività. 2. Connessione della versione Fibra Ottica (JetNet 3008f): Connettere la porta fibra del vostro Jet Net 3008f ad un altro dispositivo Fibra – Ethernet, seguendo la figura sotto. Una cattiva connessione causerà il cattivo funzionamento della porta. Servizio Clienti Korenix KoreCARE è il Servizio Clienti globale di Korenix Technology, dove il nostro staff tecnico è pronto e sempre disponibile a risolvere i vostri problemi. La e-mail del Servizio Clienti Korenix è: [email protected] Settaggi del Commutatore per i contatti di allarme � Questo è un prodotto LASER/LED Classe 1. Non sostare nell’emissione del Laser ATTENZIONE RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin No. # Stato Descrizione ON Per attivare allarme su questa porta ON Per attivare l’allarme guasto alimentazione Off Per disattivare allarme su questa porta Off Per disattivare l’allarme guasto alimentazione

Промышленный коммутатор сети Ethernet JetNet 3008/3008f соответствует стандартам

IEEE 802.3 и 802.3u и поддерживает 8 портов 10/100Base TX (JetNet 3008) или 6 портов 10/100TX плюс 2 оптоволоконных порта 100FX Fast Ethernet в любом режиме - многомодовом (JetNet 3008f-m) или одномодовом (JetNet 3008f-s). JetNet3008/3008f выполнен в прочном металлическом корпусе для работы в окружающей среде с температурами -25~70 OC и имеет стандартную степень защиты IP30. В коммутаторе предусмотрен один вывод реле для информирования пользователя о сбое передачи данных по портам или о сбое питания. Разрешить/запретить сигналы тревоги можно с помощью 9-pin dip-переключателя. JetNet 3008/3008f рекомендуется запитывать постоянным током с напряжением 24В из диапазона 12~48В через съемный терминальный 6-pin клеммный блок. Введение Комплект содержит � JetNet 3008 / 3008f коммутатор � Руководство по быстрой установке � CD с руководством пользователя Установка устройства � Крепление на DIN рейку: защелкните установленную на тыльной стороне коммутатора JetNet 3008/ 3008f клипсу крепления на DIN рейке. Более полное описание установки на DIN рейку читайте в руководстве пользователя. Заземление коммутатора JetNet 3008 / 3008f На задней стороне коммутатора JetNet 3008/3008f находится винт заземления, который необходимо соединить с системой заземления для гарантии безопасности работы и устранения шумов (см. рис. 1). Описание комплекта поставки PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Рис. 1

Подключите «плюс» и «минус» питания к

соответствующим контактам V+ и V- на съемном клеммном блоке. Тщательно затяните винтами концы проводов. См. рис. 2 Примечание: Рекомендованное напряжение питания постоянного тока 24В (12~ 48В). Как показано на рисунке 3, релейный вывод расположен по центру съемного клеммного блока и является нормально открытым. После подключения проводов к контактам и установки соответствующего DIP переключателя (Port Alarm в состояние «On») релейный вывод тревог замкнется в случае ошибки любого порта. Подключение заземления В промышленности существует довольно большой ряд устройств (двигатели переменного тока, сварочные аппараты, источники питания), производящих электромагнитные шумы, способные существенно снизить и даже прервать связь. Для устранения влияния таких шумов коммутатор должен быть заземлен, как показано на рис. 4. Подключение релейного выхода Maximum 1A current / DC 24V Рис. 3 PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural Рис. 4 Рис. 2

Соединение с сетью

1. Соединения по порту Ethernet: Подключите один конец кабеля Ethernet с портом UTP коммутатора JetNet 3008/3008f, а другой конец кабеля - к требуемому сетевому устройству. Все порты UTP автоматически поддерживают функцию MDI/MDIX. Индикатор скорости будет гореть, если связь осуществляется на скорости 100Mb, и будет выключен, если на скорости 10Mb. Индикатор LNK/ACT будет гореть при наличии связи и мигать в момент приема/передачи пакетов данных. Оптический порт поддерживает только 1 индикатор для контроля Связи и Активности. 2. Соединение по оптоволоконному порту (JetNet 3008f) : Подключите оптоволоконный порт Вашего JetNet 3008f к другому оптоволоконному устройству Ethernet как показано на рисунке справа. Неправильное подключение приведет к некорректной работе линии связи. Установки DIP переключателей для релейного выхода тревог � Не смотрите в направлении лазерного/светодиодного луча. ВНИМАНИЕ RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B P1 to P8 (Pin1 ~ 8) P9 Pin №. Статус Описание Включен Включена тревога ошибки передачи данных по порту. Включен Включена тревога сбоя питания. Выключен Выключена тревога ошибки передачи данных по порту. Выключен Выключена тревога сбоя питания.

JetNet 3008/3008f 産業用イーサネットスイッチはIEEE 802.3と802.3uの規格に適合し 8ポート

の 10/100Base TX (JetNet 3008) または 6ポートの10/100TX と2ポートの100FX Fastイーサ ネットマルチモードファイバ(JetNet 3008f-m) または シングルモードファイバ (JetNet 3008f-s) の3種類があります。JetNet 3008/3008fは厳しい環境(-25~70 OC)で動作するように頑丈なメタル のケースの設計を採用してます。また、IP-30の保護規格に適合してます。ポートのリンクに失敗し たり、電源がうまく供給されない時は、ユーザにアラームを知らせるための1つのリレー出力を持 っているということが特長です。これらのアラームは9ピンのDIPスイッチによって、エネーブル/ デセーブルにセット出来ます。JetNet 3008/3008f は6ピンの取り外し可能はターミナルブロック の電源を供給しますが、12~48V のレンジで、DC 24V の電源を供給することをお勧めします。 はじめに � JetNet 3008/3008f スイッチ � クイック・インストレーション・ガイド � CD ユーザマニュアル マウントについて � Din-Rail マウント: JetNet 3008/3008f の後 にねじりこんであるDIN rail クリップをDIN rail 上 にマウントしてください。 DIN Railのインストールに関しては、ユーザマニュアルを 参照してください。 JetNet 3008 / 3008fスイッチのアースの取り方 JetNet 3008/3008f の下側に1つのグランド用 のねじがあります。安全で、ノイズを防ぐために図-1 のようにグランドの表面とこのグランド用ねじの間 をワイヤで接続ください。 パッケージの中身(チェックリスト) PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural 図-1

1. ターミナルブロックのコネクタ上のV+ と V- の

コンタクトへプラスとマイナスのワイヤを挿入ください。 2. DC のワイヤが緩むのを防ぐため、ワイヤクランプの ねじをきつく締めてください。 図-2をご覧ください。 注記: 推奨する動作電圧はDC24V (DC12~ 48V)です. リレー出力のアラームのコンタクトは、図のように、終 端のブロックコネクタを真ん中にあります。 ワイヤを 挿入し、それぞれのポートアラームのDIPスイッチ ONにセットすることによりリレー出力アラーム はどんなポートの不具合も見つけて、回路の短絡を 作ります。アラームリレー出力は、“Normal Open”.です。 図-3をご覧ください。 アースグランドのワイヤリング 産業用途の環境において、電磁波ノイズを発生 させる多くのデバイスがあります。例えば、 ACモータ、電気溶接機、発電機です。 これらの デバイスは通信を妨げる電気ノイズやサージを 発生させます。 これらのノイズを防ぐためにこの スイッチはよくアースされていなければいけません。 図にどうのようにアースするかが示されています。 図-4をご覧ください。 リレー出力のワイヤリング Maximum 1A current / DC 24V PW1 Alm PW2 Alarm Control port 1~8 power Alarm System Extra Power System PW1 Alm PW2 Alarm Control port 1~8 power Earth Ground Screw Earth Ground Warning: Do not connect to AC line-Natural 図-2 図-3 図-4

1. 1.イーサネットポートの接続: JetNet 3008/3008fのUTPポートに、イーサネットケーブルの

片側の端をつないでください。反対側の端はネットワークデバイスに接続してください。 すべての UTPポートは、自動MDI/MDIX機能をサポートします。速度を示すLEDは100Mbpsのリンクの時は 点灯し、10Mbpsのリンク時は非点灯です。LNK/ACT用のLEDがリンクアップの時は点灯し、デー タを送受信している時は点滅します。ファイバポートだけ1つのリンクとアクティビティのLEDを サポートしています。 2. 光ファイバポートの接続(JetNet 3008f) : 図に従って, JetNet 3008fの上にファイバポートをイ ーサネットデバイスのファイバポートにつないでください。 間違った接続をするとファイバポート がただしく動作しません。 Korenixのカスタマ・サービス KoreCARE は Korenix のグローバルなサービスセンタです。ここには専門的なスタッフがいつで もあなたの問題を解決する準備が出来ています。 Korenix のグローバルなサービスセンタのE-mailアドレスは [email protected]です。 � これはクラス1の Laser/LED 製品です。 Laser/LEDのビームを目に入れては いけません。 注意 RX TX RX TX Cable Wiring(SC to SC) RX A TX B TX A RX B DIP スイッチのアラーム・リレー出力の設定 P1 to P8 (Pin1 ~ 8) P9 Pin No. # ステータス 説明 ON ポートリンクアラームをイネーブルにする。 ON パワーフェイルのアラームをイネーブルにする。 Off ポートリンクアラームをデセーブルにする。 Off パワーフェイルのアラームをデセーブルにする。

Tel:+886-2-82193000 Fax:+886-2-82193300 Business service:[email protected] Customer service:[email protected] CPQ000N3008000 V0.2 Jet Indu