Install the stand-alone BLUEbox device to the installation place.

A 12 V supply voltage is provided by a CPS22x mains adapter. Switch on the system power and see that the “module”, “link” and “video” -indicators on the front panel of the device are lit. The “module” should lit green to show that hardware is operating properly. Connect all needed audio/data signals to their respective connectors on the device’s rear panel. Connect either a CVBS video signal to the BNC connector or a S-VIDEO signal to the mini-DIN connector of the device. Connect the Ethernet ...

Technical Specifi cations

Parameter Specifi cation Note Ethernet Number of ports 1 half/full duplex Standard 10/100Base-TX CAT-5 Protocols Video/Audio/Data UDP, IP, TCP/IP Management SNMP, HTTP, Telnet, DHCP, SAP Generic ICMP, IGMP, ARP Connectors RJ-45 CAT-5 Video Number of channels 1 Standard PAL/NTSC selectable CVBS/S-video selectable Nominal level 1.0 Vpp CVBS, Y 0.3 Vpp C Impedance 75 ohms Encoding/decoding MPEG-2 MP@ML ISO/IEC 13818 Resolution H: 720, V: 576 (PAL) max H: 720,V: 480 (NTSC) max Frame rate 25 (PAL), 30 (NTSC) GOP structure I, IP, IPB, IPBB selectable at encoder Output bit ...

BLUEbox Mechanical Connections

1. Composite (CVBS) video input / output (BBE / BBD), BNC female connector. 2. S-video (Y/C) input / output (BBE / BBD), 4 pin min-DIN female connector. 3. 2 audio inputs / outputs (BBE / BBD), RJ-45 female connector. 4. 3 EIA-RS data interfaces, RJ-45 female connector. 5. Management interface for device’s local management operation, RJ-45 female connector. 6. Ethernet 10/100Base interface (CAT-5), RJ-45 female connector. 7. Supply voltage connector (+ 12 VDC) Indicator Leds There is three dual colour leds on the front panel; video-led indicates state of video, ...

On enable level the user is able to view device settings

(and on admin rights it is also possible to update the device software version). Enable level is activated by entering command enable (or en) on disable level --> “IPx#” text appears on the screen. Entering ? displays a list of commands for enable level. CLI session is terminated by entering command exit or quit. Commands: confi gure terminal (c t) - Activate confi g level disable (d) - Back to disable level end (en) - Back to enable level (no operation in this level) exit (ex) -Terminate CLI session ping (p) [IP addr ...

TCP/IP (Transmission Control Protocol/

Internet Protocol) The basic communication language or protocol of the Internet. It can also be used as a communica- tions protocol in a private network (either an intranet or an extranet). When you are set up with direct access to the Internet, your computer is provided with a copy of the TCP/IP program just as every other computer that you may send messages to or get information from also has a copy of TCP/IP. Telnet (“Terminal Emulation”) Protocol that enables you to log in to other computer systems on the Internet. Terminal Computer terminal; a de ...

Confi g-line level

On confi g-line level the user is able to change terminal view settings. Confi g-line level is activated by entering command line-console (or l c) on confi g level --> “IPx(config-line)#” text appears on the screen. Entering ? displays a list of commands for confi g-line level. To read device settings, the user must return to enable level by entering command end (or en). Commands: end (en) - Back to enable level exec-timeout (exe) [timeout in min] [timeout in sec] - Sets the exec timeout in minutes and secunds exit (ex) - Back to confi g level no exec-timeout (n e) ...

To change the password, fi rst click

heading “Change Password” under the Administration menu on the left column. Administration / change password window appears on the right side of page (picture 21). On this page you can change your username and password. Note! Use only characters and numbers. Do not use special characters! Username: Username of which you are logged in to the interface. Old Password: Current password. New Password: New password. Retype New Password: Verifi cation of the new password. User management To access user management functions, adm ...

Teleste EASI IP Series user guide recommended for: P73928EH, EASI INE101, Fritz!Box 7490, M200, MCC101.

⚠️ Download Safety

The Media Converter Operation & user’s manual (44 pages) is completely safe to download (last scan date: 06/03/2026).

Related PDF Instructions for Teleste EASI IP Series:

Media Converter Equipment: Frequently Requested

Have some Questions about Teleste EASI IP Series Device?

Get valuable and actionable advices from other Teleste EASI IP Series device users. Describe your problem or question, regarding the using of EASI IP Series, in as much detail as possible, and other users will be able to answer you.