DynaLock 2280 Installation Manual
Text of the manual
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
HANDLING
MECHANICAL INSTALLATION
ELECTRICAL INSTALLATION
INSTALLATION DESCRIPTION
The Series 2280 is a 1200 pound holding force
electromagnetic lock designed to secure a single
outswinging door. The lock requires installation
procedures as described herein and in the separate
wiring instructions included.
Typical installation of the lock on a
RHR single outswinging door:
Care must be taken that the lock face and armature face are kept free of dirt, rust, paint, or any other obstruction
which may interfere with the lock and armature making good contact. These faces may be cleaned with a non-
abrasive pad and wiped with an oil dampened cloth.
Familiarize yourself with the door and frame conditions. The lock must mount rigidly to the under side of the door
frame header. The door mounted armature is supplied with hardware that allows it to pivot slightly to compensate
for reasonable misalignment.
NOTE: If this lock is supplied with the DSM option be certain that magnets are present inside the armature
housing.
After mechanical installation is complete the lock needs to be wired to a 12 or 24 VDC/VAC power source. Once low
voltage power is supplied the unit is fully operational. All other wiring is for selected options. Refer to the separate
wiring instructions included for further information.
2280 LOCK ASSEMBLY
ARMATURE
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
(1) Electric Drill
(1) #2 Phillips Screw Driver
(1) Soft Faced Mallet
(1) Hammer
(1) Center Punch
(1) Pencil & Tape
Drill Bits: 1/8”, 17/64”, 11/32”, 1/2”, 9/16”, 21/32”
REQUIRED TOOLS
HARDWARE KIT CONTENTS
(P/N 301304)
General Information........................................... 1
Bill Of Materials................................................. 2
Mounting Considerations................................... 3
Using The Template........................................... 3
Mounting The Armature..................................... 4
Mounting The Lock............................................ 5
Exploded Parts View.......................................... 6
Exploded Parts Legend...................................... 7
Support............................................................... 8
TABLE OF CONTENTS
MODEL #2280
BILL OF MATERIALS
(1) 2280 LOCK ASSEMBLY
(1) ARMATURE
(1) ARMATURE HOUSING
(1) HARDWARE KIT
(1) MOUNTING TEMPLATE
(1) INSTALLATION MANUAL
(1) WIRING MANUAL
QTY.
ITEM
DESCRIPTION
7
Baseplate Mounting Screws
#10x1” phillips pan head sheet metal screw
7
Baseplate Mounting Screws
#10-24x1/2” phillips pan head machine screw
1
Armature Mounting Screw
5/16-18x2” hex � at head machine screw, turned
4
Armature Housing Screws
#8x1” phillips � at head sheet metal screw
4
Armature Housing Screws
8-32x3/8” phillips � at head machine screw
1
Armature Spacer
3/8”Dx0.360”L spacer
1
Steel Washer
1/4” � at steel washer
1
Door Spacer
5/8”Dx1-11/16”L spacer
1
Sex Nut
5/16-18 sex nut
2
Anti-Tamper Plug
1
3/16” Hex Wrench
NOTE: For further parts clari� cation refer to the Exploded Parts View on page 6 or consult factory.
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Inspect the door frame and determine if an angle bracket, � ller or spacer plate will be required for installation.
Note: Remember to leave space so that the door hits the stop
the maglock, to prevent loosening over time.
MOUNTING CONSIDERATIONS
USING THE TEMPLATE
Fold the template on the dotted line to form a 90 degree
angle. Scoring the template with a straight edge and a
screwdriver will make it fold easier.
With the door in the closed and latched position, from
the push side, place the template against the header
and door with one edge against the vertical strike jamb
and tape in place.
Transfer all hole locations to both the door and header
with a center punch, then remove the template from
the door.
Referring to the template drill two 1/8” dia. lock
mounting holes (or tap for 10-24) and one 9/16” dia.
wiring hole in the top of the frame, at the transferred
locations. Remaining mounting holes will be drilled
after lock is � rst mounted and adjusted (page 5).
1.
2.
3.
4.
Drill the remaining transferred holes in the face of the door to accept the Armature, following the instructions
on page 4 for your speci� c door type.
5.
*See Price Book or visit www.dynalock.com - 4000 Series Mounting Accessories
���������
��������
����� ����
�� ����
�� �� �� ������ ���� ���� ��
�� ������� ���� ��
���� ������� ������� ��
��� ��� ���� ����� ��� �
���� ������� ������ �
���� ������� ������� �
��� ���� ��� ���� ���� ���� ��
�� �� ����� ���� ������ ����� ��� �� ������
����� ��� ����� ��� ������ ��� ������ �
�� �� ������� ���� ������ ������ ������ ��� �� ���� �
�� �� �� �� �������� �� ��� �� ���� ��� ������� ����� ��
����� ���������� ���
�����������
���������������
����
��������
������������������������������������������������������������������������
����������������������������������������������������������
���� ������� ������ �
���� ������� ������� �
�� ���� ��� ��� ������� �����
NORMAL
MOUNTING
FILLER PLATE
REQUIRED*
SPACER PLATE
REQUIRED*
ANGLE BRACKET
REQUIRED*
2-3/8”
2-3/8”
2-1/8”
2-1/8”
1/2”
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
MOUNTING THE ARMATURE
Mount the Armature Housing to the door using four (4) #8 x 1” sheet metal screws or #8-32 x 3/8” machine
screws.
Place the Armature inside the Armature Housing and secure using the proper hardware, according to the above
illustrations. Firmly tighten the Armature mounting screw with a 3/16” hex wrench.
Failure to properly secure the Armature to the door could result in serious injury or possible security
breach.
From the three illustrations below, select the one that resembles your door type and follow the instructions for drilling
the Armature Mounting Screw hole. (See Template)
Drill four (4) 1/8” dia. holes for #8 x 1” sheet metal screws or drill and tap for #8-32 x 3/8” machine screws (See
Template).
GLASS AND ALUMINUM
OR HOLLOW METAL DOOR
SOLID CORE DOOR
REINFORCED DOOR
Drill an 11/32” diameter hole
through the door. From the
sex nut side only enlarge the
hole to 21/32” diameter.
Drill an 11/32” diameter hole
through the door. From the
sex nut side drill 1/2” diameter
hole to 1” depth.
Drill a 17/64” diameter hole
and tap for 5/16-18 thread
��������
����� ������
��������
�����
� � � �
������
���
���
������
��������
�������
��������
������
����� ������
��������
�����
��������
������
����
��
��������
��������
�������
����� ������
��������
�����
��������
������
�������� ������
��������
��������
�������
1/4” MIN
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
MOUNTING THE LOCK
2. Align the Lock and Armature. Close
and latch the door. Temporarily mount the
lock to the baseplate and verify:
a) the lock face and armature are
making full contact for the entire length
of the armature
b) the armature is horizontally centered
on the lock face
c) the door hits the frame just before the
maglock (not slamming on the lock)
If any adjustment is required, gently tap the
baseplate with a soft mallet until full contact
is achieved. Mark two baseplate corner
locations lightly with a pencil for reference.
Remove the lock from baseplate and
tighten both adjustment screws. Drive the
remaining 5 screws into the header using
the baseplate as a physical template.
Screw heads must not project above the
baseplate.
ARMATURE AND
LOCK FACE MUST
MAKE FULL CONTACT
MAGLOCK
SHOULD BE PARALLEL
HEADER
3. Attach the Lock to the Baseplate. With the
3/16” Hex wrench, permanently fasten the lock to
the Baseplate with the two 1/4"-20 x 1-1/4" ma-
chine screws removed earlier.
BASEPLATE
1. Mount the Baseplate to the header. Separate the
baseplate from the lock housing with a 3/16” Hex wrench.
Place the Baseplate against the header with the counter
sunk slots visible, and the large slot over the wire
hole. Attach the baseplate to the header at both slotted
locations using the holes drilled on page 3. Tighten the
screws just snug enough to allow for � nal adjustment.
4. Install the tamper plugs. Gently tap the two
Anti-Tamper Plugs into the Mounting Screw Holes
using a soft faced mallet.
5. Complete Wiring. See separate wiring instructions.
LOCK
ANTI-TAMPER PLUG
SOCKET HEAD
MOUNTING SCREW
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
EXPLODED PARTS VIEW
LEGEND ON
NEXT PAGE
12-3/4"
1-13/16"
1-1/2"
7-3/8"
2-3/8"
10"
2"
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
1/4”
11/16”
1/2”
17
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
ITEM
DESCRIPTION
PART #
1
Baseplate
301264
2
#10x1” Self-Tapping Screw
*
2
10-24x1/2” Machine Screw
*
3
Lock Housing
301297
4
Access Cover
301296
5
8-32x3/8” Machine Screw
300608
6
Anti-Tamper Plug
*
7
1/4-20x1-1/4” Socket Head Screw
300603
8
5/16-18x2” Arm. Screw, Turned
*
9
Armature
300968
ITEM
DESCRIPTION
PART #
10
#8x1” Self-Tapping Screw
*
10
8-32x3/8” Machine Screw
*
11
Armature Housing
301245
12
0.360”L Armature Spacer
*
14
Steel Washer
*
15
Door Spacer Tube
*
16
Sex Nut
*
17
Disc Magnet (DSM only)
301289
PARTS LEGEND
* Part of Hardware Kit (301304)
Refer to Page 6 for parts locations.
2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
UL
C
R
US
LISTED
PLEASE DELIVER THIS MANUAL
TO THE END-USER UPON COMPLETION
OF THE INSTALLATION
GWXT Auxiliary Lock
FOR PRODUCT SUPPORT AND PARTS
ORDERING INFORMATION CONTACT:
DynaLock Corp.
705 Emmett Street
Bristol, CT 06010
Bus: (877) DYNALOCK, Toll-Free USA
(860) 582-4761
Fax: (860) 585-0338
DYNALOCK ON THE INTERNET:
E-mail: [email protected]
Website: www.dynalock.com
CSFM
NYC Mea #23-92-E
THE FOLLOWING LISTINGS ARE PENDING