TPI 133 Instruction Manual

File Specifications

Brand: TPI
Category: Multimeter
Model: 133 (Instruction Manual), prARAYfWh83Xw
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 24 pages

Download PDF

Download TPI 133 Manual (24 pages)

Read Online:

Read the TPI 133 Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Fuse, 2 Amp

A102 Fuse, 10 Amp A110 Test Lead Set A040 Rubber Boot (133 only) A101 Optional Accessories Part No. Deluxe Test Lead Set SDK1C IEC 1010 Deluxe Test Lead Kit TLS2000BC Temperature Adapter A301 Boot Hook A103 Soft Carrying Case A100 *These accessories have not been evaluated by UL and are not considered as part of the UL Listing of this product. www.GlobalTestSupply.com Find Quality Products Online at: [email protected] ...

Disconnect power from the terminal

block, find the fuse or circuit breaker that controls the block and turn it off. Set up the meter following the steps under “Measurement Procedure” on page 13. Then proceed with the following: • Connect the red test lead to the hot side of the block and the black lead to the neutral side of the block. Reconnect power to the block and read the voltage on the meter. The reading should be approximately 110V to 130V. • Disconnect power from the block and move the red wire to ground. Reconnect power to the block and read the voltage on t ...

Fuse, 2 Amp

A102 Fuse, 10 Amp A110 Test Lead Set A040 Rubber Boot (133 only) A101 Optional Accessories Part No. Deluxe Test Lead Set SDK1C IEC 1010 Deluxe Test Lead Kit TLS2000BC Temperature Adapter A301 Boot Hook A103 Soft Carrying Case A100 *These accessories have not been evaluated by UL and are not considered as part of the UL Listing of this product. www.GlobalTestSupply.com Find Quality Products Online at: [email protected] ...

±0.5% Basic DCV Accuracy (also see pages 9-11)

Function Range Resolution DCV 200mV 0.1mV 2V 0.001V 20V 0.1V 200V 0.1V 1000V 1V ACV 200mV 0.1mV 2V 0.001V 20V 0.01V 200V 0.1V 750V 1V DCA 200µA 0.1µA 2mA 0.001mA 20mA 0.01mA 200mA 0.1mA 2A 0.001A 10A 0.01A ACA 200µA 0.1µA 2mA 0.001mA 20mA 0.01mA 200mA 0.1mA 2A 0.001A 10A 0.01A OHM 200 0.1 2k 0.001k 20k 0.01k 200k 0.1k 2M 0.001M 20M 0.01M Test Voltage Max. Test Current Diode 2.5V Approx. 1mA Test Voltage Threshold Continuity 2.5V <100 www.GlobalTestSupply.com Find Quality Products Online at: [email protected] ...

Battery Replacement: The 133 will display BAT when

the internal 9 Volt battery needs replacement. The battery is replaced as follows: a. Disconnect and remove all test leads from live circuits and from the 133. b. Remove the 133 from its protective boot. c. Remove the three screws from back of 133 housing. d. Carefully pull apart front and rear instrument housing. e. Remove old battery and replace it with new battery. f. Reassemble instrument in reverse order from above. 2. Fuse Replacement: Both of the 133 “A” and “mAµA input jacks are fuse protected. Use only Fa ...

CAUTION: RISK OF ELECTRIC SHOCK

AC (ALTERNATING CURRENT) DC (DIRECT CURRENT) REFER TO INSTRUCTION MANUAL GROUND FUSE DOUBLE INSULATION ON/OFF, PUSH BUTTON SWITCH C. TECHNICAL DATA 1. Features and Benefits Safety Meets CE and IEC 1010 requirements. UL Listed to U.S. and Canadian Safety Standards. Large LCD Easy to read at all angles and the majority of lighting levels. Rubber Boot Added protection when the instrument is dropped. (133NB does not include boot.) M ...

Perform the following tests and/or measurements

with the TPI 133 and the appropriate function: HVAC/R FUNCTION DCmV • Thermocouples in furnaces or gas applications. ACA • Heat anticipator current in thermostats. ACV • Line voltage. ACV or DCV • Control circuit voltage. DCµA • Flame safeguard control current. OHMS • Heating element resistance (continuity). OHMS • Compressor winding resistance. OHMS • Contactor and relay coil resistance. OHMS • Continuity of wiring. DCmV • Temperature with optional temperature adapter (A310). ELECTRICAL FUNCTION ACV � ...

TPI 133 user guide recommended for: 183A, 120, 135, 196, 183.

⚠️ Download Safety

The Multimeter Instruction manual (24 pages) is completely safe to download (last scan date: 14/02/2026).

Related PDF Instructions for TPI 133:

Multimeter Equipment: Frequently Requested

Have some Questions about TPI 133 Device?

Get valuable and actionable advices from other TPI 133 device users. Describe your problem or question, regarding the using of 133, in as much detail as possible, and other users will be able to answer you.