Dell S5000 Configuration Manual

Text of the manual

A Dell Deployment and Configuration Guide

Dell Networking S5000 Switch Configuration Guide for SC Series iSCSI SANs Dell Storage Engineering February 2016

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

Revisions Date Description August 2014 Initial release February 2016 Update for FW version 9.9.0.0 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. © 2014–2016 Dell Inc. All rights reserved. Dell, the DELL logo, and the DELL badge are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims any proprietary interest in the marks and names of others.

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

Table of contents Revisions ............................................................................................................................................................................................. 2 1 Introduction ................................................................................................................................................................................ 4 1.1 Audience ........................................................................................................................................................................... 4 1.2 Switch details ................................................................................................................................................................... 4 1.3 Cabling diagram .............................................................................................................................................................. 5 2 Dell recommended switch configuration ............................................................................................................................. 6 2.1 Hardware configuration ................................................................................................................................................. 6 2.2 Delete startup configuration ......................................................................................................................................... 6 2.3 Disabling Data Center Bridging (DCB) configuration ............................................................................................... 6 2.4 Configure out of band (OOB) management port ..................................................................................................... 7 2.5 Configure route for OOB management port (optional) .......................................................................................... 7 2.6 Configure login credentials ........................................................................................................................................... 7 2.7 Enable switch ports ........................................................................................................................................................ 7 2.8 Enable Jumbo Frames.................................................................................................................................................... 8 2.9 Enable flow control ........................................................................................................................................................ 8 2.10 Configure spanning tree on edge ports ...................................................................................................................... 8 2.11 Configure VLAN ............................................................................................................................................................... 8 2.12 Save configuration .......................................................................................................................................................... 9 2.13 Configure additional switch .......................................................................................................................................... 9 3 Configure UPM ports as Ethernet Pass-through (Optional) ............................................................................................ 10 3.1 View the current configuration .................................................................................................................................. 10 3.2 Configure port group 0 as Ethernet Pass-through ................................................................................................. 10 3.3 To revert Ethernet Pass-through to FC ports ........................................................................................................... 11 Additional resources ....................................................................................................................................................................... 12

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

1 Introduction This document shows how to configure Dell™ Networking S5000 switches for use as a dedicated iSCSI SAN with Dell SC Series storage using Dell best practices. 1.1 Audience This switch configuration guide describes an optimal configuration following Dell best practices for an SC Series iSCSI SAN and is intended for storage or network administrators and deployment personnel. 1.2 Switch details The table below provides an overview of the switch configuration. Table 1 Switch specifications Dell Networking S5000 Switch vendor Dell Switch model S5000 Switch firmware 9.9.9.0 or later Note: For proper functionality, the switch must be at the firmware version shown in the table above before proceeding with this configuration. Using previous firmware versions may have unpredictable results. The latest firmware updates and documentation can be found at: www.force10networks.com. This site requires a login.

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

1.3 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and SC Series. Figure 1 Cabling diagram SC Series

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

2 Dell recommended switch configuration These steps outline how to configure two S5000 switches for use as an iSCSI SAN with SC Series storage. 2.1 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using any terminal utility, open a serial connection session to the switch. 4. Open the terminal emulator and configure it to use the serial port (usually COM1, but this may vary depending on the system). Configure serial communications for 9600,N,8,1 and no flow control. 2.2 Delete startup configuration Note: This example assumes a switch at its default configuration settings. Using the delete startup- config command will set the startup configuration file to its default settings. You should always backup your configuration settings prior to performing any configuration changes FTOS>enable FTOS#delete startup-config Proceed to delete startup-config [confirm yes/no]yes FTOS#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 2.3 Disabling Data Center Bridging (DCB) configuration Note: For non-DCB environments, DCB must be manually disabled using the following steps: FTOS>enable FTOS#configure FTOS(conf)#no dcb enable FTOS(conf)#exit FTOS#copy running-config startup-config

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

2.4 Configure out of band (OOB) management port FTOS>enable FTOS>#config FTOS(conf)#interface Managementethernet 0/0 FTOS(conf-if-ma-0/0)#no shutdown FTOS(conf-if-ma-0/0)#ip address ipaddress mask FTOS(conf-if-ma-0/0)#exit 2.5 Configure route for OOB management port (optional) FTOS (conf)#management route X.Y.Z.0 /24 A.B.C.1 Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The example above assumes a class C subnet mask. 2.6 Configure login credentials FTOS(conf)#username admin password yourpassword privilege 15 FTOS(conf)#enable password yourpassword 2.7 Enable switch ports Option 1: You can enable ports individually by entering the port number FTOS(conf)#interface tengigabitethernet 0/0 FTOS(conf-if-te-0/0)#switchport FTOS(conf-if-te-0/0)#no shutdown FTOS(conf-if-te-0/0)#exit Option 2: You can enable multiple ports at once using the “range” parameter FTOS(conf)#interface range tengigabitethernet 0/0 – 47 Note: The message below will be displayed if there are FC ports. % Warning: Non-existing ports (non configured) are ingnored by interface-range

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

FTOS(conf-if-range-te-0/0-47)#switchport FTOS(conf-if-range-te-0/0-47)#no shutdown 2.8 Enable Jumbo Frames FTOS(conf-if-range-te-0/0-47)#mtu 12000 2.9 Enable flow control FTOS(conf-if-range-te-0/0-47)#flowcontrol rx on tx off 2.10 Configure spanning tree on edge ports Note: Use the following command only on server- and storage-connected edge ports. FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port FTOS(conf-if-range-te-0/0-47)#exit FTOS(conf)#protocol spanning-tree rstp FTOS(conf-rstp)#no disable FTOS(conf-rstp)#exit 2.11 Configure VLAN Note: Dell recommends assigning a unique vlan_id (between 2-4094) for each switch fabric. For example, assign VLAN 100 on the first switch and VLAN 200 on the second switch. The following example assigns all the ports to the VLAN, however, you may also assign individual ports to the VLAN after they are enabled (Section 2.7). If you prefer to use the default VLAN, then you may skip this section entirely. FTOS(config)#interface vlan vlan_id FTOS#(config-if-vl-###)#no shutdown FTOS#(config-if-vl-###)#untagged tengigabitethernet 0/0-47 FTOS#exit

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

2.12 Save configuration FTOS#copy running-config startup-config 2.13 Configure additional switch Repeat the commands from Section 2 to configure the second switch.

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

3 Configure UPM ports as Ethernet pass-through (optional) The FC ports on the Unified Port Module (UPM) can be configured as Ethernet pass-through. Use this section only if the UPM module is used. The 12 ports are divided into six port groups numbered 0-5. Two ports in each port group can be configured separately as FC or Ethernet pass-through. Note: This operation requires a reload for the changes to take effect. 3.1 View the current configuration Use this command to view the current mode of the ports and also the port group mapping. FTOS# show system stack-unit 0 port-group portmode PortGroupId Ports Mode(Curr Boot) Mode(Next Boot) 0 0,1 FC FC 1 2,3 FC FC 2 4,5 FC FC 3 6,7 FC FC 4 8,9 FC FC 5 10,11 FC FC 3.2 Configure port group 0 as Ethernet pass-through FTOS(conf)# stack-unit 0 port-group 0 portmode Ethernet Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required.

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

3.3 To revert Ethernet pass-through to FC ports FTOS(conf)# no stack-unit 0 port-group 0 portmode ethernet Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1 obsolete after a save and reload. [confirm yes/no]:yes Please save and reload for the changes to take effect. Note: Save and reload is required.

Dell Networking S5000 Switch Configuration Guide for SC Series SANs

Additional resources Dell.com/support is focused on meeting your needs with proven services and support. DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications:  Dell Storage Compatibility Matrix: http://en.community.dell.com/techcenter/storage/w/wiki/5069.dell-storage-compatibility-matrix- ps-series-sc-series-fs-series  For SC Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to SC Series Technical Documents: http://en.community.dell.com/techcenter/storage/w/wiki/5018.sc-series-technical-documents