The sensor must be grounded. You can ground the sensor via the piping if the joints in the pipeline are ground-bonded. If

the sensor is not grounded via the piping, connect a ground wire to the internal or external grounding screw, which is located on the transmitter, core processor, or junction box. Ground the flowmeter to earth, or follow ground network requirements for the facility. Improper grounding can cause measurement error. If national standards are not in effect, follow these guidelines to ground the sensor: • Use copper wire, 14 AWG (2,0 mm²) or larger wire size. • Ke ...

Environmental Limits for Typical Sensors

Notes • When ambient temperature is below –40 °F (–40 °C), a core processor or Model 2400S transmitter must be heated to bring its local ambient temperature to between –40 °F (–40 °C) and +140 °F (+60 °C). Long-term storage of electronics at ambient temperatures below –40 °F (–40 °C) is not recommended. • Temperature limits may be further restricted by hazardous area approvals. Refer to the hazardous area approvals documentation shipped with the sensor or available from the Micro Motion web site (www.micromotion ...

EN-1092 Flange Pressure Ratings

Pressure Rating (bar) Flange Type ASTM Material ≤50C 100C 150C 200C 250C 300C 350C 400C 427C EN 1092-1 PN40 Form B1 11 weld neck 304 40.0 34.4 30.8 28.0 26.0 24.1 23.0 22.0 21.4 EN 1092-1 PN40 Form B1 & D 11 weld neck 316 40.0 40.0 36.3 33.7 31.8 29.7 28.5 27.4 26.9 EN 1092-1 PN100 Form B2 & D 11 weld neck 316 100.0 100.0 90.9 84.2 79.5 74.2 71.4 68.5 67.3 EN 1092-1 PN40 Form B1 32/02 lap joint C-22 collar/ 304 flange 40.0 34.4 30.8 28.0 26.0 24.1 23.0 22.0 21.4 22 Micro Motion ELITE Coriolis Flow and Density Sensors ...

© 2009, Micro Motion, Inc. All rights reserved. P/N 20002158, Rev. DA

*20002158* For the latest Micro Motion product specifications, view the PRODUCTS section of our web site at www.micromotion.com. Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T +1 303–527–5200 +1 800–522–6277 F +1 303–530–8459 Micro Motion Europe Micro Motion Asia Emerson Process Management Emerson Process Management Neonstraat 1 1 Pandan Crescent 6718 WX Ede Singapore 128461 The Netherlands Republic of Singapore T +31 (0) 318 495 555 T +65 6777–8211 F +31 (0) 318 ...

© 2009, Micro Motion, Inc. All rights reserved. P/N 20002158, Rev. DA

*20002158* For the latest Micro Motion product specifications, view the PRODUCTS section of our web site at www.micromotion.com. Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T +1 303–527–5200 +1 800–522–6277 F +1 303–530–8459 Micro Motion Europe Micro Motion Asia Emerson Process Management Emerson Process Management Neonstraat 1 1 Pandan Crescent 6718 WX Ede Singapore 128461 The Netherlands Republic of Singapore T +31 (0) 318 495 555 T +65 6777–8211 F +31 (0) 318 ...

Mounting a CMF010 Sensor to a Wall or Pole

The CMF010 sensor has an optional mounting configuration for use with small or flexible pipeline. If the pipeline adequately supports the sensor, this procedure can be skipped. Procedure 1. Locate the optional mounting holes. For sensors with a junction box, the junction box must be rotated to the side to expose the mounting holes. See Figure 5. Figure 5 Optional Mounting for CMF010 Sensors A B C A Two user-supplied 5/16″ (M8) bolts B Junction box or core processor (junction box shown) C Mounting surface 2. If necessary, install rigid stand ...

Emerson Micro Motion ELITE user guide recommended for: Rosemount Model 500, Fisher 249, Daniel 3812, X-STREAM Series, Rosemount CT5800.

⚠️ Download Safety

The Measuring Instruments Installation manual (26 pages) is completely safe to download (last scan date: 30/01/2026).

Related PDF Instructions for Emerson Micro Motion ELITE:

Measuring Instruments Equipment: Frequently Requested

Have some Questions about Emerson Micro Motion ELITE Device?

Get valuable and actionable advices from other Emerson Micro Motion ELITE device users. Describe your problem or question, regarding the using of Micro Motion ELITE, in as much detail as possible, and other users will be able to answer you.