WARNING!
Important instructions for the safety of people:
READ CAREFULLY!
Foreword
• Use of the products must be restricted to its intended use
(i.e. that for which it was expressly built for). Any other use is
to be considered dangerous. Came Cancelli Automatici S.p.A.
is not liable for any damage resulting from improper, wrongful
or unreasonable use • Keep these warnings with the installa-
tion and use manuals issued with the automated system.
Before installing
(preliminary check: in case of a negative
outcome, do not proceed before having
complied with the safety obligations)
• Make sure that the parts you intend to automate are in
good working order, and that they are properly balanced
and aligned. Also, make sure that proper mechanical stops
are already in place • If the operator will be installed at a
height of less than 2.5 m from the ground or other access
level, check whether you will need any protections and/or
warnings • Any gate leaves, fi tted with pedestrian entrances,
onto which you will install an operator, must have a blocking
mechanism when the gate is in motion • Make sure that the
opening of the automated gate is not an entrapment hazard
as regards any surrounding fi xed parts • Do not mount the
operator upside down or onto any elements that may fold
under its weight. If needed, add suitable reinforcements at
the points where it is secured • Do not install onto gates on
either an upward or downward slope (i.e. that are not on fl at,
level ground) • Check that any lawn watering devices will not
wet the gearmotor from the bottom up.
Installation
• Carefully section off the entire site to prevent unauthorised
access, especially by minors and children • Be careful when
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling
safety equipment • All opening commands (e.g. buttons, key
selectors, magnetic detectors, etc.) must be installed at least
1.85 m from the gate’s area of operation perimeter - or where
they cannot be reached from the outside of the gate. Also,
the direct commands (e.g. push button, or proximity devices,
etc.) must be installed at a height of at least 1.5 m and must
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release
mechanism • Before delivering to the client, verify that the
system is EN 12453 (impact test) standard compliant. Make
sure that the operator has been properly adjusted and that the
safety and protection devices, as well as the manual release
are working properly • Where necessary and in plain sight,
apply the Warning Sings (e.g. gate plate).
Special instructions and
advice for users
• Keep the gate’s area of operation clean and clear of any
obstacles. Trim any vegetation that may interfere with the
photocells • Do not allow children to play with the fi xed com-
mand devices, or in the gate’s area of operation. Keep any
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether
any anomalies or signs of wear and tear appear on the moving
parts, on the component parts, on the securing points, on the
cables and any accessible connections. Keep any joints (i.e.
hinges) lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on
photocells and sensitive edges, every six months. Keep glass
panels constantly clean (use a slightly water-moistened cloth;
do not use solvents or any other chemical products) • If the
system requires repairs or modifi cations, release the operator
and do not use it until safety conditions have been restored
• Cut off the power supply before releasing the operator for
manual openings. See instructions • Users are FORBIDDEN
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL
ASSISTANCE STAFF • On the periodic maintenance log, note
down the checks you have done.
Special instructions and
advice for all
• Avoid working near the hinges or moving mechanical parts
• Stay clear of the gate’s area of operation when in motion •
Do not resist the direction of movement of the gate; this may
present a safety hazard • At all times be extremely careful
about dangerous points that must be indicated by proper
pictograms and/or black and yellow stripes • When using
a selector or command in ‘maintained action’ mode, keep
checking that there are no people in the area of operation of
the moving parts. Do this until you release the command •
The gate may move at any time without warning • Always cut
the power when cleaning performing maintenance.
EN
1. GENERAL POINTS
These general conditions shall apply to all purchase agreements for Came Cancelli Automatici SpA materials, hereinafter called “the
company”.
2. OFFERS AND QUOTATIONS
The company’s quotations are valid for a 30-day period at the most starting from the date they are sent.
3. ORDERS
The sale agreement is executed once the written order is confirmed by Came Cancelli Automatici Spa or when the order is fulfilled by
the company. Orders that are addressed, and signed by clients, to Came Cancelli Automatici SpA are deemed to be firm and irrevocable
for 30 days starting from the date they are received by the company. Any change or addition to the single provisions of these general
conditions or single provisions of the order which was originally addressed by the client, shall have no validity unless otherwise approved
in writing by the company. For any changes to the order, the company reserves the right to cancel both the changes an the original order.
The delivery date for the goods appearing on the orders is always and in any case exclusively indicative, and any delays of such term may
never justify claims for compensation or cancellation of contract.
Particularly, the company reserves the right to extend the delivery terms or cancellation of order in the event of: force majeure or events
that are beyond the control of the company; change of the Client’s legal status; difficulty in sourcing raw materials and component parts.
4. DELIVERY AND FORWARDING
The place of production or registered office of the company shall be the place of fulfilment for delivery. The cost and risk of the travelling
goods is borne by the buyer ex works, pursuant to the 2000 incoterms. Unless otherwise agreed, the company establishes, for and on
behalf of the client, the type of shipping, the travel route and type of carrier. The company reserves the right to carry out partial deliveries
and fulfilment of orders, thereby issuing a separate invoice each time: in this case all partial deliveries shall be autonomously invoiced and
the terms of payment shall begin as of the date on each invoice; the client may not, therefore, defer payment of partial orders, until the last
delivery is made as concerns the original order.
5. PRICES AND PRICE LISTS
The prices are intended for goods delivered free to the company’s registered office, not including VAT, with normal packaging, and not
including forwarding expenses. Any reference to list prices shall refer to the latest price list published by the company, which theretofore
cancels any previous price lists.
6. PAYMENTS
Non-payment within the established terms, shall result in the application of interest pursuant to Lgs. Decr. 09/10/2002 n. 231 and
subsequent amendments and upgrades, with any possible greater damage unprejudiced. Any delay in payment, shall mean that the client
shall owe the company, any losses due to exchange rates. The client may not advance any demands nor raise any exceptions as concerns
the company, unless after having paid the goods it purchased. The company reserves the right to block all shipping and supply orders
underway in the face of any irregularities in the payments, without need of prior notice nor compensatory damages of any kind.
7. RETURNS AND CLAIMS
All claims must be filed in writing within 8 days of receiving the goods, whether such claims refer to the quantity or quality of the delivered
goods. Returned goods shall be accepted by company only following a written agreement, and only for new and packaged goods. Any
returned goods must be complete of their relative transport documents, showing the company’s written authorisation to accept the
returned goods including the quality and quantity of the returned goods.
The returned goods shall not be accepted by the company unless carried out in the above mentioned manner and, especially, returned
goods shall not be accepted if received at any of the company’s premises.
8. GUARANTEE
The company guarantees the proper functioning of the products that it provides, as per the technical characteristics that are expressly
shown on its products’ technical sheets. The guarantee shall not apply in the case of any environmental interferences of any nature, which
could cause disturbances in the functioning of any existing or future installations (radio frequencies – proximity of electric power lines…).
The guarantee does not cover the normal wear and tear of the equipment, or mistakes made during the mounting phase or due to
maintenance flaws, and in any case it does not cover any cases in which flaws in the functioning can be traced back to factors stemming
from anything other than manufacturing.
The deadlines for filing a claim for any flaws or for the statute of limitations for actions to which the buyer is entitled are those foreseen by
Italian law. The company at its own leisure, may decide to withdraw any goods supplied which it has ascertained as faulty, or decide to
repair said ascertained flaws. The client may not request to be compensated for any indirect damages, missed gains, production losses,
and in any case may not expect as compensation any sums greater than the value of the supplied components or products.
9. REPAIRS
Repairs to purchased items request by the client shall be carried out by the company following an agreement on the price of said repairs.
In any case the expenses for labour and shipping (roundtrip) shall be borne by the client.
10. RESERVATION OF TITLE
It is expressly agreed that, any delivered goods remain owned by the company until the client pays the entire balance, regardless of who
is in possession of said goods. Transport expenses and any other expenses needed to retrieve the equipment, therein including any
extraordinary expenses as well as any repeatable ones, shall be borne by the client.
11. APPLICCABLE LAW – SETTLEMENT OF ANY DISPUTES Any arising dispute resulting from the sale agreement, shall be settled
according to the Italian law, thereby excluding any other law and in supplement to the Vienna Convention on the international sale of
goods. All disputes shall be subject to Italian jurisdiction and come under the exclusive competence of the Tribunal of Treviso, Italy.
12. PROVISIONS ON THE SAFEGUARDING OF PERSONAL DATA.
Pursuant to current legislation for the safeguarding of personal data, clients are aware that their personal data is inputted into the
company’s databank, which is necessary for the proper carrying out of the contractual relationship and for compliance with certain
provisions of law, as well as for purposes of statistics, promotion, marketing, commercial, credit protection, management and transfer of
the same .
The personal data of the buying party are processed through automated and paper-based tools by authorised persons, by using safety
procedures designed to guarantee confidentiality. The personal data of the client may by shared with Public Bodies, companies of the
group, credit recovery firms, or consortiums or associations with business scopes, market research scopes, or marketing scopes. The
data processor shall be the company, and the client may address said company to uphold their own rights as per law. To this end the
buying party is aware that at any time it may access its personal data, ask that it be updated, corrected and/or prohibit it from being used.
General conditions of sale
Pag. 2 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
4.1 Automation
4 Description
2.1 Intended use
1 Legend
This symbol indicates sections to be read with particular care.
This symbol indicates sections concernig safety.
This symbol indicates notes to communicate to users.
This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.
2 Destination and limits of use
The V700E automated kit is designed to power sectional and overhead doors installed in condominiums and residential homes.
The use of this product for purposes other than as described above and installation executed in a manner other than as
instructed in this technical manual are prohibited.
3 Reference standards
“IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION”
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS”
2.2 Limits to use
24V (d.c.) gearmotor with lifting force of up to 850N for:
- counterweighted overhead doors up to 2.40m in height;
- spring-balanced overhead doors up to 3.25m in height;
- sectional doors up to 3.20m in height.
V700E was designed and manufactured by CAME CANCELLI AUTOMATICI S.p.A. and is compliant with the safety regulations in force.
Guaranteed 24 months if not tampered with.
The automation is mainly made up of an engine block, a transmission rail - with either a belt or chain transmission system - and a
transmission arm. Inside the ABS container which features a window for the courtesy light, we fi nd: the 24V gearmotor, the control
panel and the transformer.
The gearmotor is made up of an aluminium die cast casing, which houses a worm-screw and helical-crown gear irreversible reduction
system, lubricated by permanent fl uid grease.
The transmission guide is made of cold-pressed galvanised sheeting. At the front end there is belt/chain tension device; fastened to the
other end is an ABS support to hold up the gear motor.
Inside the transmission guide runs the traction slide which includes the emergency release mechanism and the bracket for fastening to
the transmission arm.
The transmission arm is available in several sizes and shapes depending on the type of garage door.
4.2 Description of the parts
GEARMOTOR SECTION
1) Protective cover
2) Gearmotor
3) Transformer
4) ZL56A circuit board
5) Standard transmission arm
Pag. 3 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Important! Check that the safety equipment and accessories are CAME originals; this is a guarantee that also makes the system easy
to set up and upkeep.
TRANSMISSION GUIDES
V0679 - Chain guide unit L= 3.02 m
V0684 - the same as the V0679 but two parts need assembling
- counterweighted overhead doors up to 2.40 m in height;
- Spring balanced overhead doors up to 2.25 m in height;
- sectional doors* up to 2.20 m in height.
V0682 - Chain guide unit L= 3.52 m
- Spring balanced overhead doors up to 2,75 m in height;
- sectional doors* up to 2.70 m in height.
V0683 - Chain guide unit L= 4.02 m
- Spring balanced overhead doors up to 3.25 m in height;
- sectional doors* up to 3.20 m in height.
V0685 - Belt guide unit L= 3.02 m
V0687 - the same as the V0685 but two parts need assembling
- counterweighted overhead doors up to 2.40 m in height;
- spring balanced overhead doors up to 2.25 m in height;
- sectional doors* up to 2.20 in height.
V0686 - Belt guide unit L= 3.52 m
- spring balanced overhead doors up to 2.75 m in height;
- sectional doors* up to 2.70 m in height.
V0688 - Belt guide unit L= 4.02 m
- spring balanced overhead doors up to 3.25 m in height;
- sectional doors* up to 3.20 m in height.
* see page 5 (5.4 Applicative examples).
4.3 Technical specifications
GEARMOTOR V700E
Power supply: 230V A.C. 50/60Hz
Motor power supply: 24V D.C.
Max. power of 24V accessories: 40W
Rated power: 260W
Max. torque: 850Nm
Average speed: 6m/min
Operative intermittence: 50 %
Protection level: IP40
Weight: 5,8 kg
Insulation class: ||
OPTIONAL TRANSMISSION ARMS
1) 001V201 - Transmission arm for counterweighted overhead garage doors.
2) 001V122 - Extra-strength transmission arm for sectional garage doors;
OPTIONAL ACCESSORIES
1) 001V121 - Pull-string release mechanism to affix onto the handle;
2) 001V0670 - Emergency battery start-up card, houses 2 (12V-1,2Ah not
included) batteries ;
Pag. 4 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
5 Installation
Make sure all tools and materials necessary are within reach to install the edge in total safety, and in compliance with the regulations
in force. The following figure illustrates the minimum equipment needed by the installer.
Before proceeding with the installation, it is necessary to:
• Make sure the area selected for the mounting of the base and for the unit itself is hazard free;
• Provide for a suitable omnipolar disconnection device with contacts more than 3 mm apart, and independent (sectioned off) power
supply;
• Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as
compared to the other conductive parts inside;
• Make sure that the point where the gearmotor is fastened is protected from impact and that it is sturdy. The fastening must be carried
out using screws and/or rivets that are suitable for the type of surface;
• Make sure that any connections inside the container (made for the continuity of the protection system) are provided with additional
insulation compared to the other conductive parts inside;
• Make sure that the door has a sturdy enough structure, that the hinges be in proper working order and that there is friction between
moving and fixed parts;
The installation must be carried out by export, qualified personnel in total compliance with the norms in effect.
5.1 Preliminary checks
5.2 Tools and materials
4.4 Dimensions
H - 100mm
H
Pag. 5 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual
power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.
When connecting products other than those mentioned in this manual please see the documents provided with the products themselves.
5.3 Cable list and minimum thickness
Connections
Type of cable
Length of cable 1 < 10 m
L. of cable 10 < 20 m
L. of cable 20 < 30 m
230V power supply
FROR CEI 20-22
CEI EN
50267-2-1
3G x 1,5 mm2
3G x 2,5 mm2
3G x 4 mm2
Flashing lamp
2 x 0,5 mm2
2 x 1 mm2
2 x 1,5 mm2
Photocell transmitters
2 x 0,5 mm2
2 x 0.5 mm2
2 x 0,5 mm2
Photocell receivers
4 x 0,5 mm2
4 x 0,5 mm2
4 x 0,5 mm2
24V power supply to accessories
2 x 0,5 mm2
2 x 0,5 mm2
2 x 1 mm2
Control and safety devices
2 x 0,5 mm2
2 x 0,5 mm2
2 x 0,5 mm2
Antenna connection
RG58
max. 10 m
1) Gearmotor unit
2) Incorporated control panel with radio transmitter
3) Transmission guide
4) Release device
5) Standard transmission arm
6) Key-switch selector
7) Flashing light movement indicator
8) Tuned antenna
9) Safety photocells
10) Indoor push button control
11) Safety sensitive profi le
5.4 Applicative examples
* single-guide sectional door
* double-guide sectional door
COUNTERWEIGHTED PARTIALLY RETRACTABLE SWING OUT
OVERHEAD DOOR
SPRING BALANCED FULLY RETRACTABLE SWING OUT OVERHEAD DOOR
SECTIONAL DOOR
M6 x 20
M6
����������
������������
����������
V122
V201
Pag. 6 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
The following applications are only examples, as the space required for unit installation and the accessories vary depending on
dimensions and therefore it is up to the installer to select the best solution.
2) Position the transmission guide in the following manner:
- for sectional doors directly above spring-release coiling shaft (between 20 and 30 mm of the shaft’s axis).
N.B.: if the distance between the coiling shaft and the top part of the door is between 300 and 600 mm, use the V122 arm (see
technical documentation attached);
1) Fasten the bracket to the tension device on the transmission guide using the supplied bolts and washers.
- for overhead doors between 10 and 20 mm from the highest sliding point of the door.
N.B.: for pratially-retractable swing out counterweighted garage doors, use the V201 arm (see technical documentation attached).
5.5 Preparing the transmission guide
M6 x 14
M6
Pag. 7 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
1) Fasten the transmission guide to the centre of the doorway using the proper screws.
Raise the guide until it is horizontal with the ceiling so as to choose the proper type of fastener.
2) If the angle brackets are not suffi cient, cut the tension brackets down to the right length and fasten them to the ceiling.
N.B.: to strengthen the bar additional angle or tension brackets may be installed (item code 119RIE024 and 119RIE028)
3) Fasten the transmission guide to the ceiling using the proper bolts.
5.6 Fastening the transmission guide
M6 x 20
Pag. 8 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
1) Fasten the guide arm to the top of the door frame, perpendicularly to the transmission guide. Use the supplied rivets and other
suitable bolts and screws.
5.7 Fastening the guide arm to the transmission guide
2) Release the traction slide by turning the small level clockwise.
Move the slide towards the door and hook it onto the guide arm with the supplied bolt.
UNI 6954 ø 3.9 x 13
UNI 6955 ø 6.3 x 45
�
�
Pag. 9 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
5.8 Fastening the gearmotor to the transmission guide
1) Remove the cover of the motor unit.
2) Fasten the motor unit to guide’s support racket using the three screws supplied with the kit.
N.B.: if needed, the unit may be fasten in the other three perpendicular positions, as per the drawings.
3) Affi x the cable gland in the hole used to convey the electrical cables.
10 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
6.1 General description
6 Electronic control panel
The control panel is powered by 230V on the L-N terminals, with a 50/60 Hz frequency.
The command devices and accessories run on 24V. Moreover, the total accessories cannot run on more than 40W.
The panel controls a service light to light up the service area; at each opening it lights up for 2 minutes and 30 seconds.
The V0670 card may be connected to operate the automation kit with emergency batteries (see the technical documentation attached).
The card automatically controls the following functions:
1) amperometric detection of obstructions during opening, closing and during slow down phases (with adjustable sensitivity);
2) automatic closing (adjustable);
3) working cycle (80”);
4) open-stop-close-stop command
5) reopening dueing the closing phase of the photocells.
in the closing phase: invert the direction of movement until
completely opened;
Warning! After three, consecutive inverted cycles,
the door will stay open excluding automatic closing
function: to close the door, use the remote control or a
command button.
in the opening phase: invert the direction of
movement until completely closed;
FUSES
Protection
Fuse type
Motor
7,5A
Circuit board (line)
1,6A
Accessories
3,15A
Command devices (control unit)
315mA
LIGHTS
Service
E14 24V 25W
Detail of the amperometric detection of obstructions:
11 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
6.2 Main components
1) Line fuse 1.6A
2) Emergency batteries’ slot
3) Gearmotor
4) Transformer
5) Transformer connection terminal board
6) Motor fuse 8A
7) Gearmotor connection terminal board
8) Encoder connection terminal board
9) Signal Led for radio-code and encoder programming
10) Radio-code save button
11) SLOW. SENS: adjustment of amperometric sensitivity during closing
phase
12) TCA Trimmer: adjustment of automatic closing cycle
13) CL. SENS Trimmer: adjustment of amperometric sensitivity during
closing phase
14) OP. SENS Trimmer: adjustment of amperometric sensitivity during
opening phase
15) Command buttons for end-stop adjustment
16) Function selector
17) Courtesy light
18) Accessories’ fuse 3,15A
19) Central control unit fuse 315mA
20) Accessories’ and control device connection terminal board
21) “AF” radiofrequency board socket
22) Electrical cable sockets
23) Led indicator for power-on
24) Power supply terminal board
25) Radio antenna terminal board
6.3 Electrical Connections
Power supply and accessories
Teminal board for accessories’ power supply:
- at 24V a.c. normally;
- at24V d.c. when the emergency batteries are in operation;
Maximum total power allowed: 40W.
Buttonhole terminal for earth connection
Power supply
230V a.c. - 50/60 Hz
Warning! Before doing any work on the automation kit, cut off the pwer
supplì and disconnect the emergency batteries (if connected).
12 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
RED
Gearmotor, encoder and transformer (only for possibile maintenance)
RED
BLACK
WHITE
BROWN
BROWN
GREEN
GREEN
BROWN
WHITE
Gearmotor
24V d.c. with
encoder
Transformer
Command and safety devices
Stop button (N.C. contact) - Stops movement, excludes the automatic closing functions. To restart
the automated kit, press a command button or a remote control button.
Key and/or push button selector switch (N.O. contact) - Opening and closing devices.
Command modes: open-stop-close-stop
N.C. Contact for “reopening during closing”
- Input for photocells, sensitive profi les and other devices
complying with EN 12978 standards.
During the closing phase, operating the device will invert the
motion until complete opening is achieved.
If a device is connected up,
remove the small bridge.
Key switch and/or button for partial opening (N.O. contact) - Partial opening devices
If a device is connected up,
remove the small bridge.
13 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Movement Flasher (contact capacity:
24V – 25W max.)
Flashes during the opening and closing
phases.
Warning devices
6.5 Adjustments
6.4 Function selection
Trimmer SLOW.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during different phases,
slow-down; if said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
Trimmer A.C.T. = Adjusts the waiting time in the opening position. Once this time frame has lapsed, an automatic closing procedure is
performed. The waiting time may be adjusted to between 1 second and 120 seconds. Adjusting to the minimum excludes the automatic
closing function.
Trimmer CL.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement closing; if
said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
Trimmer OP.SENS. = Adjusts the amperometric sensitivity that controls the force of the engine developed during movement opening; if
said force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.
1 ON - Activates the procedure for adjusting the opening and closing endpoints and the procedure for programming the decelerated
opening.
2 ON - Activates the procedure for adjusting the partial opening and the procedure for programming the decelerated endpoint
closing.
14 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
7 Programming
- Release the automation and position the door in the fully opened position.
IMPORTANT: before performing any programming, read the instructions carefully.
Carry out the following instructions in the proper order otherwise the programming will fail.
- When the door is fully opened, fasten the mechanical stop to the traction slide.
1 - Preliminary operations
- Position dip-switch n°1 to ON (the programming signal led fl ashes).
Push and keep pressed the AP/CH switch until the door closes...
2 - Programming the end-stop in the closing phase
- Manually close the door until the release is locked into place again.
7.1 Programming the end-stop in the closing and opening phase
ACC. FUSE 3,15A-F
LINE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
N
CL.SENS.
ZL56A
OP.SENS.
MOTOR FUSE
8A-F
2
1
ON
ACC. FUSE 3,15A-F
LINE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
CL.SENS.
ZL56A
OP.SENS.
MOTOR FUSE
8A-F
2
1
ON
ACC. FUSE 3,15A-F
E FUSE
6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
CL.SENS.
ZL56A
OP.SENS.
MOTOR FUSE
8A-F
2
1
ON
ACC. FUSE 3,15A-F
NE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
CL.SENS.
ZL56A
OP.SENS.
MOTOR FUSE
8A-F
2
1
ON
ACC. FUSE 3,15A-F
NE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
Pag. 15
15 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
...then press the ENC/RADIO button until the signalling led stays on for some seconds and then resumes blinking (the programming
operation is satisfactorily complete).
- Push and keep pressed the OPEN button until the door is fully open...
3 - Programming the end-stop in the opening phase
...then press the ENC/RADIO button until the signalling led stays on (the programming operations is satisfactorily complete).
Finally, set dip switch n°1 back to OFF.
TEST
Use the AP/CH button to command both an opening and a closing to verify whether the programming was successful.
ACC. FUSE 3,15A-F
NE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
��������
��������
�
����
�������
��
���������
������
���������
��������
��������
����
�������
��
���������
��������
��������
����
�������
��
���������
������
��������
��������
�
�
��
����
�������
��
�
�
�
�
�
���������
������
���������
�
�
Pag. 16
16 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
With the door is completely closed, set DIP switch 2 to ON (the signalling led fl ashes).
Press and keep the OPEN button pressed until the door reaches the desired point of opening...
7.3 Programming for decelerated opening when door is open (50% of the opening arc max.)
Note: before programming, deactivate the automatic closing by adjusting the A.C.T. Trimmer to its minimum setting.
With the gate completely open, press and keep pressed the ENC/RADIO button (the signalling programming led fl ashes quickly).
Set DIP switch 1 to ON (the signalling LED turns off).
Release the ENC/RADIO button (the signalling LED fl ashes slowly).
...then press the ENC/RADIO button (if the signalling LED stays on the programming procedure is successfully complete).
Set DIP switch 2 back to OFF
7.2 Programming for partial opening
17 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
7.4 Programming for closing deceleration (600 mm from the closing stop minimum, or 50% of the opening/closing arc)
With the door completely closed, press and keep pressed the ENC/RADIO button (the signalling programming LED fl ashes quickly).
Set DIP switch 2 to ON (the signalling LED turns off).
Release the ENC/RADIO button (the signalling LED fl ashes quickly).
Press the OP/CL button until the gate reaches the fi nal point of deceleration you require; then press the ENC/RADIO button until the
signalling LED staus on ( the programming procedure is completed succesfully).
Set DIP switch 1 back to OFF.
Press the OPEN button until the door reaches the point of beginning deceleration you require; then press the ENC/RADIO button until the
signalling LED stays on (the programming procedure is successfully completed).
Set DIP switch 2 back to OFF.
ACC. FUSE 3,15A-F
LINE FUSE
1,6A-F
OPEN
OP / CL
AF
26V 17V 0V
M
N
+
E
-
ENC/RADIO
A.C.T.
SLOW.SENS
C.BOARD FUSE 315mA-F
L1T
L
L2T
N
����
����������
�������
���������
���������
��
���
�
���
�
ATOMO
AT01 • AT02 • AT04
CAME
CAME
CAME
CAME
CAME
CAME
CAME
TOP
TOP-432NA • TOP-434NA
TOP-432S
TOP
TOP-302A • TOP-304A
TOP
TOP-432A • TOP-434A
TAM
T432 • T434 • T438
TAM-432SA
CAME
CAME
CAME
TOUCH
TCH 4024 • TCH 4048
TWIN
TWIN2 • TWIN4
CAME
CAME
CAME
CAME
CAME
CAME
TFM
T132 • T134 • T138
T152 • T154 • T158
AF43S
AF30
AF40
AF150
AF43TW
TWIN
TWIN2 • TWIN4
Pag. 18
18 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Radiofrequency card
Electrical board
8 Activating the remote control
Connect the radiofrequency card to the electrical board AFTER SHUTTING OFF THE POWER (or disconnecting the batteries).
N.B.: The circuit board recognizes the readiofrequency card only when it is running in electrical power.
Connect the antenna with the RG58 cable to the apposite terminals on the board.
1 - Antenna
2 - Radio frequency
3 - Transmitters
WARNING! Can memorise up to a maximum of 24 transmitters that have different codes.
Note: each transmitter that has a different code, may be duplicated for “n” transmitters (of the same series), except for the ATOMO
transmitter.
See attached
instructions
See attached
instructions
See attached
instructions
See attached
instructions
in Key-Block
Mode
in TOP or
TAM modes
See attached instructions
19 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Flashing LED
ENC/RADIO
Lit LED
AF Card
Keep the ENC/RADIO pressed on the circuit board. The led indicator will fl ash.
press the transmitter button (T1) to be memorised. The led indicator will stay on to confi rm memorisation.
Flashing LED
ENC / RADIO
Lit LED
AF Card
OP / CL
First, keep the ENC/RADIO button pressed (the led indicator fl ashes) and then press the OP/CL button on the control board.
Press the (T2) button of the transmitter you wish to memorise. The signalling LED stays on to signal the memorisation has taken place.
Set DIP switches 1 and 2 to ON (the signalling LED, starts to fl ash), keep the ENC/RADIO button pressed for 5 seconds (the signalling led
starts to fl ash quickly and stays on to signal that deletion has taken place).
Set the DIP switches back to OFF.
ENC / RADIO
Flashing LED
Lit LED
Activating the (2-3P) partial opening command
Deleting all of the memorised radio users
Activating the (2-7) sequential command
4 - Memorising and deleting radio users
20 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
10 Maintenance
10.1 Periodic maintenance
Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check
that the safety devices work properly; remove any obstructions.
We suggest checking the state of lubrication and tightness of the anchoring screws on the operator.
- To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing. If the operator inverts
the motion or stops, the photocells are working properly.
This is the only maintenance procedure to be carried out with the power source connected.
- Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to heavy door
movement.
9 Safety instructions
This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The
manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses.
Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in motion.
Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.
Do not allow children to play or loiter within the opening/closing arc of the operator. Keep remote controls and any other command
device out the reach of children, to prevent operator from being activated by accident.
In the event of anomalous behaviour, stop using the operator immediately.
Important safety instructions
Danger of crushing hands
Danger of crushing feet
Danger! High voltage
No transit during operation
21 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
- To clean the photocells use a water dampened cloth. Do not use solvents or other chemical products which may ruin the devices.
- In the event of any strange vibrations or squeaking, lubricate the joints with grease, as shown in the diagram.
- Make sure there are no plants within the photocell’s beam, and that the heavy door motion is free of any obstacles.
10.2 Problem solving
MALFUNCTIONS
REFERENCES
CHECKS
The automation does not open nor close
1-3
1 - Check the power supply and the line fuses
The automation opens but does not close
4-10-23
3 - The N.C. (1-2) safety contact is open
The automation closes but does not open
23
4 - The N.C. (2-C1) safety contact is open
The automation does not automatically close
9-10
5 - The N.C. safety contacts are open
The remote control does not work
12-14
6 - Deactivate the obstruction detection function using the dip-
switches
The automation exerts too much force
16
9 - Check that the A.C.T. trimmer is not set to minimum
The automation exerts too little force
16-17-23-24
10 - Check the proper direction of motion
The automation inverts the direction of movement
16-17-23-24
11 - N.C. command button instead of N.O.
Only one remote control works
18
12 - Check the fuse bridge on AF43S, remove/put power back on
The photocell does not work
4-19
14 - Memorise the radio code again
The led indicator flashes quickly
4-25-26
16 - Ad just the sensitivity using the TRIMMER
The led indicator stays on
11
17 - Eliminating mechanical friction
The led power-on indicator is off
3-1
18 - Insert (or duplicate) the same code in all the remote controls
The automation does not work with the
emergency batteries
6-21-22
19 - Check the proper functioning of the photocell
The automation inverts the direction of movement
at the end of the cycle
10-17-23
21 - Check the batteries
The automation starts slowly
17-23-24
22 - Respect the polarity of the photocells and accessories
23 - Checking the balancing of the overhead door
24 - Checking the tension of the belt/chain
25 - Encoder multifunctioning: cut off and give back power to the card
26 - Erroneous Encoder connection: check the connections
22 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
10.3 Extra-ordinary maintenance
The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised
firms.
N.B.: Any extraordinary maintenance must be performed by specialised technicians.
Extra-ordinary maintenance log
Date
Notes
Signature
Periodic maintenance log for end-user (every 6 moths)
Installer’s stamp
Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed ________________________________________________________________________________________
__________________________________________________________________________________________________
Installer’s stamp
Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed ________________________________________________________________________________________
__________________________________________________________________________________________________
Installer’s stamp
Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed ________________________________________________________________________________________
__________________________________________________________________________________________________
23 - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
MANUFACTURER’S DECLARATION OF CONFORMITY
Pursuant to annex II B of the Machinery Directive 98/37/EC
CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: [email protected]
Declares under its own responsibility that the equipments for automatic garage doors and gates listed below:
… comply with the National Law related to the following European Directives and to the applicable parts of the
following Standards.
98/37/CE - 98/79/CE
MACHINERY DIRECTIVE
98/336/CEE - 92/31/CEE
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE
73/23/CEE - 93/68/CE
LOW VOLTAGE DIRECTIVE
89/106/CEE
CONSTRUCTION PRODUCTS DIRECTIVE
EN 13241-1
EN 12635
EN 61000-6-2
EN 12453
EN 12978
EN 61000-6-3
EN 12445
EN 60335-1
EN 60204-1
IMPORTANT WARNING!
Do not use the equipment specifi ed here above, before completing
the full installation
In full compliance with the Machinery Directive 98/37/EC
MANAGING DIRECTOR
Mr. Gianni Michielan
12 Manufacturer’s warranty
Reference code to request a true copy of the original: DDF B EN V010d
AUTOMATION DRAW SYSTEM FOR V700E OVERHEAD AND SECTIONAL DOORS
CONTAINING SOME OF THE FOLLOWING ACCESSORIES
V201 - V121 - V122 - V0670 - V0679 - V0682 - V0683 - V0684
V0685 - V0686 - V0687 - V0688
11 Phasing out and disposal
CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at
its plants, to ensure that environmental safeguarding.
We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies,
by simply following these brief guidelines when disposing:
DISPOSING THE PACKING MATERIALS
The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty, by
simply separating them so that they can be recycled.
Before actions it is always advisable to check the pertinent legislation where installation will take place.
DO NOT DISPOSE OF IN NATURE!
DISPOSING OF THE PRODUCT
Our products are made using different types of materials. The majority of them (aluminium, plastic, iron, electric cables) can be conside-
red to be solid urban waste. They may be recycled at authorised firms.
Other components (electrical circuit board, remote control batteries etc.) may contain hazardous waste.
They must, thus, be removed and turned in to licensed firms for their disposal.
Before acting always check the local laws on the matter.
DO NOT DISPOSE OF IN NATURE!
Installer’s stamp
Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed ________________________________________________________________________________________
__________________________________________________________________________________________________
Installer’s stamp
Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed ________________________________________________________________________________________
__________________________________________________________________________________________________
English - Manual code: 119EU87
119EU87 ver. 0.1
0.1 01/2009 © CAME cancelli automatici s.p.a.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
CAME
CAME France
France S.a.
S.a.
FRANCE
7, Rue Des Haras
Z.i. Des Hautes Patures
92737 Nanterre Cedex
Nanterre Cedex
(+33) 1 46 13 05 05
(+33) 1 46 13 05 00
GERMANY
CAME Gmbh
CAME Gmbh
Kornwestheimer Str. 37
70825 Korntal
Korntal Munchingen Bei Stuttgart
(+49) 71 5037830
(+49) 71 50378383
CAME Automatismes S.a.
CAME Automatismes S.a.
FRANCE
3, Rue Odette Jasse
13015 Marseille
Marseille
(+33) 4 95 06 33 70
(+33) 4 91 60 69 05
GERMANY
CAME Gmbh Seefeld
CAME Gmbh Seefeld
Akazienstrasse, 9
16356 Seefeld
Seefeld Bei Berlin
(+49) 33 3988390
(+49) 33 39883985
CAME Automatismos S.a.
CAME Automatismos S.a.
SPAIN
C/juan De Mariana, N. 17-local
28045 Madrid
Madrid
(+34) 91 52 85 009
(+34) 91 46 85 442
U.A.E.
CAME Gulf Fze
CAME Gulf Fze
Offi ce No: S10122a2o210
P.O. Box 262853
Jebel Ali Free Zone - Dubai
Dubai
(+971) 4 8860046
(+971) 4 8860048
CAME United Kingdom Ltd.
CAME United Kingdom Ltd.
GREAT BRITAIN
Unit 3 Orchard Business Park
Town Street, Sandiacre
Nottingham
Nottingham - Ng10 5du
(+44) 115 9210430
(+44) 115 9210431
RUSSIA
CAME Russia
CAME Russia
Umc Rus Llc
Umc Rus Llc
Ul. Otradnaya D. 2b, Str. 2, offi ce 219
127273, Moscow
Moscow
(+7) 495 739 00 69
(+7) 495 739 00 69 (ext. 226)
CAME Group Benelux S.a.
CAME Group Benelux S.a.
BELGIUM
Zoning Ouest 7
7860 Lessines
Lessines
(+32) 68 333014
(+32) 68 338019
CHINA
CAME (Shanghai)
CAME (Shanghai)
Automatic Gates Co. Ltd.
Automatic Gates Co. Ltd.
1st Floor, Bldg 2, No. 1755, South Hongmei Road
Shanghai
Shanghai 200237
(+86) 021 61255005
(+86) 021 61255007
CAME Americas Automation Llc
CAME Americas Automation Llc
U.S.A
11405 NW 122nd St.
Medley
Medley, FL 33178
(+1) 305 433 3307
(+1) 305 396 3331
PORTUGAL
CAME Portugal
CAME Portugal
Ucj Portugal Unipessoal Lda
Ucj Portugal Unipessoal Lda
Rua Jùlio Dinis, N. 825, 2esq
4050 327 Porto
Porto
(+351) 915 371 396
CAME Cancelli Automatici S.p.a.
CAME Cancelli Automatici S.p.a.
ITALY
Via Martiri Della Libertà, 15
31030 Dosson Di Casier
Dosson Di Casier (Tv)
(+39) 0422 4940
(+39) 0422 4941
Informazioni Commerciali 800 848095
ITALY
CAME Sud s.r.l.
CAME Sud s.r.l.
Via F. Imparato, 198
Centro Mercato 2, Lotto A/7
80146 Napoli
Napoli
(+39) 081 7524455
(+39) 081 7529190
CAME Service Italia S.r.l.
CAME Service Italia S.r.l.
ITALY
Via Della Pace, 28
31030 Dosson Di Casier
Dosson Di Casier (Tv)
(+39) 0422 383532
(+39) 0422 490044
Assistenza Tecnica 800 295830
Assistenza Tecnica 800 295830