Axio MET AX-T903 Operating Instruction

Brand: Axio MET
Category: Multimeter
Model: AX-T903 (Operating Instruction)
File Type: PDF
File Size: —
Pages: 9
Text of Axio MET AX-T903 Operating Instruction

Axio MET AX-T903 International Safety Symbols

Warning of a potential danger, comply with instruction manual. Caution! Dangerous voltage. Danger of electrical shock. Double insulation SAFETY NOTES  Reference. Please use utmost attention.  Do not exceed the maximum allowable input range of any function  Insulated personnel body protective equipment up to 690V. WARNINGS In order to avoid electrical shock, the valid safety and VDE regulations regarding excessive co

Axio MET AX-T903 The voltage testers may no longer be used if one or several functions fail or if no

functionality is indicated. Do not use this instrument under damp conditions. Perfect display I sonly guaranteed within a temperature range of -10°C up to +55°C, at relative humidity question <85%. If the operator’s safety cannot be guaranteed, the instrument must be removed from service and protected against use. The safety can no longer be insured if the instrument:

Axio MET AX-T903 ACV: +1.5% of reading +5 digit

690VAC Max. measuring current approx. ≤3.0mA 690VDC Max. measuring current approx. ≤2.5mA Voltage detection: automatic Polarity detection: full range Range detection: automatic Response time: Updates 2~3 / sec. ACV Frequency range: 50/60Hz Internal impedance: approx. ≤1MΩ Operation time Long LCD on: >4. 5V AC/DC Single-pole Phase Test: Voltage range: 100…690V AC ACV Frequency range: 50/60Hz Continuity Test Resista

double-pole and contact electrode

Self-check test Auto Operation time 5s<250V AC/DC, Is< = 0.2A(690V)/30s max. Overvoltage protection: 3s<400V AC/690V DC Power supply 2x1.5V “AAA” Batteries Temperature range: -10°C up to +55°C Humidity: max.85% relative humidity Overvoltage class: CATIII -1000V age Tester Description: 1. Handle test probe – (L1) 2. Instrument test probe + (L2) 3. measurement point

Explanations of Symbols

The voltage tester shows the following symbols: Inserting/Changing the Batteries The voltage tester is operated with two micro-batteries (type AAA, in the scope of delivery). Proceed as follows to insert or change the batteries: • Loosen the screw on the battery compartment lid (9) with a suitable screwdriver and remove it. • Insert two micro-batteries (AAA) into the battery compartment. Observe the polarity information in the

To prevent damage to the device from leaking batteries, remove the batteries from the device if

you will not be using it for a longer period. For the same reason, we recommend that you remove flat batteries immediately. Function test / Self test: • Test the voltage tester on a known source. • Warning: To avoid electric shock, disconnect the test leads from any source of voltage before turn on the self-check test function. • The “!” LED will lig

Thanks to the input impedance of approx. 1MΩ, it is possible to perform voltage tests with high

input impedances without time restrictions. The voltage tester also indicates a rotating direction (L or R) with measurements on single-phase mains (L1 against N). This is not a device malfunction. Rotating field direction display The voltage tester can show the direction of the rotating field with three-phase systems. Hold the voltage tester by the handles

Axio MET Multimeter Owners Instructions: