Pen Vibration Meter

Model VB400 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com

Extech Instruments VB400 Congratulations on your purchase of this Extech Meter. The VB400 is designed to provide easy

and accurate velocity and acceleration measurements on industrial machinery. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features • Applications for industrial vibration monitoring : • All in one pen type digital vibration meter. • Acceleration, Velocity measur

HOLD has been activated

ACC Acceleration with units : m/s2, ft/s2, g VEL Velocity with units: mm/s, cm /s, inch/s Low battery 1 2 3 4 5 6 7 8

Preparation for measurements

1. Press the POWER button to turn the meter on. 2. Check that the display is on and that the low battery icon is not on. 3. If the low battery icon appears, replace the batteries. 4. Attach either the sensing head or the magnetic base by screwing it into the vibration sensor. Measurements 1. Press the MODE button to step through and set the function (velocity or acceleration) and the units desired.

Extech Instruments VB400 Zero Adjustment Procedure

Over time the meter ‘0” may drift by a few digits. This is caused by temperature change, battery voltage and other ageing factors. Usually this small change is not of significance for typical measurements. To remove the error: 1. Open the battery compartment 2. Hold the battery lid down so contact is made and the meter can be turned on. 3. With no vibration, adjust the meter zero adjustment until the display

LCD, 20 mm x 28 mm.

Measurement Velocity, Acceleration. (RMS value). Mode Acceleration: g, m/s 2, ft/s 2 Velocity: mm/s, cm/s, inch/s Frequency range 10 Hz to 1 KHz Sampling time Approx. 1 second. Operating temperature 0 to 50°C ( 32 to 122°F ). Operating humidity < 80% RH. Power supply DC 1.5V battery ( UM-4/AAA ) x 4 PCs. Power consumption Approx. DC 12 mA. Weight 240 g ( 0.53 lb ). Dimen