Kramer VS-42UHD Operation & User’s Manual

Specifications

Brand: Kramer
Category: Matrix Switcher
Model: VS-42UHD
File Type: PDF
File Size: —
Pages: 71

Read Online

Read the Kramer VS-42UHD Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

VS-42UHD – Contents

i Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions DC 2 2.3 Recycling Kramer Products 3 3 Overview 4 3.1 Using the IR Transmitter 5 3.2 Defining the VS-42UHD 4x2 HDMI Matrix Switcher 6 4 Connecting the VS-42UHD 8 4.1 Connecting a Serial Controller via RS-232 9 4.2 Connecting to the VS-42UHD via Ethernet 9 4.3 Connecting the Remote Contact-Closure Switches 12 5 Principles of Operation 14 5.1 Automatic Signal Detection 14 5.2 Input Switching Modes 14 5.3 EDID Operation 15 5.4 Step-in Functionality 15 6 Operating the VS-42UHD 4x2 HDMI Matrix Switcher 16 6.1 Switching an Input to an Output 16 6.2 Acquiring an EDID from an Output 16 6.3 Muting and Unmuting the Outputs 17 6.4 Locking and Unlocking the Front Panel Buttons 18 6.5 Generating a Test Pattern 18 7 Configuring and Maintaining the VS-42UHD 19 7.1 Setting the DIP-Switches 19 7.2 Resetting the VS-42UHD to Factory Default Settings 20 7.3 Upgrading the Firmware 20 8 Operating the VS-42UHD Remotely via the Web Pages 21 8.1 Browsing the VS-42UHD Web Pages 21 8.2 Routing Page 23 8.3 EDID Page 27 8.4 Device Setting Page 29 8.5 Firmware Upgrade Page 30 8.6 About Us Page 31 9 Wiring the Twisted Pair RJ-45 Connectors 32 10 Technical Specifications 33 11 Default Communication Parameters 34 12 Default EDID 35 13 Protocol 3000 39 13.1 Understanding Protocol 3000 40 13.2 Kramer Protocol 3000 Syntax 42 13.3 Protocol 3000 Commands 43

VS-42UHD – Contents

Figures Figure 1: VS-42UHD 4x2 HDMI Matrix Switcher Front 6 Figure 2: VS-42UHD 4x2 HDMI Matrix Switcher Rear 7 Figure 3: Connecting the VS-42UHD 4x2 HDMI Matrix Switcher 9 Figure 4: Local Area Connection Properties Window 10 Figure 5: Internet Protocol Version 4 Properties Window 11 Figure 6: Internet Protocol Properties Window 12 Figure 7: Remote Contact-closure Switch Connections 13 Figure 8: Available Test Patterns 18 Figure 9: The Loading Page 22 Figure 10: The General Info Page 22 Figure 11: The Routing Page 23 Figure 12: The Output Buttons 24 Figure 13: The Input Buttons 24 Figure 14: The Remote Device Control Window 25 Figure 15: Test Pattern Tab 26 Figure 16: The EDID Page 27 Figure 17: The Device Setting Page 29 Figure 18: The Firmware Upgrade Page 30 Figure 19: The About Us Page 31 Figure 20: TP Pinout Wiring 32

VS-42UHD - Introduction

1 1 Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 14 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Video Products; GROUP 12: Digital Signage; GROUP 13: Audio; and GROUP 14: Collaboration. Congratulations on purchasing your Kramer VS-42UHD 4x2 HDMI Matrix Switcher. This product, which incorporates HDMI™ technology, is ideal for: • Conference rooms • Education • Hospitality

VS-42UHD - Getting Started

2 Getting Started We recommend that you: • Unpack the equipment carefully and save the original box and packaging materials for possible future shipment • Review the contents of this user manual Go to www.kramerav.com/downloads/VS-42UHD to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate). 2.1 Achieving the Best Performance To achieve the best performance: • Use only good quality connection cables (we recommend Kramer high- performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables) • Do not secure the cables in tight bundles or roll the slack into tight coils • Avoid interference from neighbouring electrical appliances that may adversely influence signal quality • Position your VS-42UHD away from moisture, excessive sunlight and dust This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building. 2.2 Safety Instructions DC Caution: There are no operator serviceable parts inside the unit Warning: Use only the Kramer Electronics power supply that is provided with the unit Warning: Disconnect the power and unplug the unit from the wall before installing

VS-42UHD - Getting Started

3 2.3 Recycling Kramer Products The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at www.kramerav.com/support/recycling/.

VS-42UHD - Overview

3 Overview The VS-42UHD is a high quality, 4x2 matrix switcher for HDMI signals. It reclocks and equalizes the signals and can route any input to either or both outputs simultaneously. In particular, the VS-42UHD features: • Up to 8.91Gbps data rate (2.97Gbps per graphics channel) Suitable for resolutions up to UXGA and 4K x 2K • Support for HDCP (High Definition Digital Content Protection) • True video clock detection • Automatic switching modes (last connected and priority switching) • HDMI Support – 3D, Deep Color, x.v.Color™, Lip Sync , ARC, HEAC pass- through, Dolby® TrueHD, Dolby Digital Plus, DTS−HD®, and 7.1 multi- channel audio • I-EDIDPro™ Kramer Intelligent EDID Processing™ – Intelligent EDID handling & processing algorithm ensures Plug and Play operation for HDMI systems • Programmable step-in functionality when used in conjunction with compatible step-in devices, such as SID-X3N, DIP-30 and DIP-31 (using an HDMI cable that supports HEC, the HDMI Ethernet Channel) • Non-volatile EDID storage • Kramer reKlocking™ & Equalization Technology that rebuilds the digital signal to travel longer distances • Static or dynamic DHCP IP addressing • Embedded Web pages that provide remote configuration and operation • A lock button to prevent unwanted tampering with the buttons on the front panel • Support for Kramer Protocol 3000

VS-42UHD - Overview

5 You can control the VS-42UHD using the front panel buttons, or remotely via: • RS-232 serial commands transmitted by a PC, touch screen system or other serial controller • The Kramer RC-IR3 infrared, remote control transmitter • A PC connected via a LAN to the Ethernet port on the VS-42UHD • An optional, external, remote IR receiver (see Section 3.1) 3.1 Using the IR Transmitter You can use the RC-IR3 IR transmitter to control the machine via the built-in IR receiver on the front panel or, instead, via an optional external IR receiver (for example, P/N C-A35M/IRR-50). The external IR receiver can be located up to 15m away from the machine. This distance can be extended to up to 60m when used with three extension cables (for example, P/N C-A35M/A35F-50). Before using the external IR receiver, be sure to arrange for your Kramer dealer to insert the internal IR connection cable (for example, P/N: 505-70434010-S) with the 3.5mm connector that fits into the REMOTE IR opening on the rear panel. Connect the external IR receiver to the REMOTE IR 3.5mm connector.

VS-42UHD - Overview

3.2 Defining the VS-42UHD 4x2 HDMI Matrix Switcher This section defines the VS-42UHD. Figure 1: VS-42UHD 4x2 HDMI Matrix Switcher Front # Feature Function 1 IR LED Lights yellow when receiving an IR signal 2 IR Sensor Signal receiver for the infrared remote control transmitter 3 ON LED Lights green when the device is powered on 4 INPUT SELECTOR TO OUT 1 1~4 Press one of the four inputs to switch it to Output 1 Press the currently selected input button to mute the output 5 INPUT SELECTOR TO OUT 2 1~4 Press one of the four inputs to switch it to Output 2 Press the currently selected input button to mute the output 6 LOCK Button Press and hold to lock the front panel buttons. Press and hold again to unlock (see Section 6.4) 7 MUTE Button Press to toggle mute of both output signals (see Section 6.3) 8 EDID Button Press to capture the EDID (see Section 6.2) 9 FUNCTION Button Press to activate the test pattern generator. When the generator is active, press one of the input buttons to select a test pattern (see Section 6.5)

VS-42UHD - Overview

7 Figure 2: VS-42UHD 4x2 HDMI Matrix Switcher Rear # Feature Function 10 INPUT 1~4 HDMI Input Connectors Connect to up to four HDMI sources (see Section 6.1) 11 REMOTE IR Opening Connect to an external IR receiver for controlling the device via an IR remote controller (see Section 3.1). Covered by a cap. The 3.5mm mini jack at the end of the internal IR connection cable fits into this opening 12 REMOTE INPUT To OUT 1 4-pin Terminal Block Connect to up to four remote, contact-closure input selection switches for Output 1 (see Section 4.3) 13 REMOTE INPUT To OUT 2 4-pin Terminal Block Connect to up to four remote, contact-closure input selection switches for Output 2 (see Section 4.3) 14 RS-232 3-pin Terminal Block Connect to a PC/serial controller (see Section 4.1) 15 SETUP 8-way DIP-switch Sets the device configuration (see Section 7.1) 16 PROG VIA USB Connector Connect to a PC to upgrade the firmware (see Section 7.3) 17 PROG VIA RS-232 Upgrade Switch Press to upgrade the firmware via the RS-232 port, release for normal operation 18 ETHERNET RJ-45 Connector Connect to a PC via a LAN (see Section 4.2) 19 RESET Switch Press while power-cycling the device to reset to factory default parameters (see Section 7.2) 20 5V DC Connector Connect to the power adapter, center pin positive 21 OUT 1 and OUT 2 HDMI Output Connectors Connect to up to two HDMI acceptors

VS-42UHD - Connecting the VS-42UHD

4 Connecting the VS-42UHD Always switch off the power to each device before connecting it to your VS-42UHD. After connecting your VS-42UHD, connect its power and then switch on the power to each device. You do not have to connect all the inputs and outputs, connect only those that are required. To connect the VS-42UHD, as illustrated in the example in Figure 3, do the following: 1. Connect up to four HDMI sources, (for example, Blu-ray Disc players) to the HDMI Input connectors. 2. Connect the two OUT HDMI connectors to up to two HDMI acceptors, (for example, LCD displays with built-in speakers). 3. If required, connect a PC/controller to the RS-232 port (see Section 4.1) and/or the Ethernet port (see Section 4.2). 4. Connect the power adapter to the device and plug the power adapter into the mains electricity (not shown in Figure 3). 5. If required, acquire the EDID (see Section 6.1).

VS-42UHD - Connecting the VS-42UHD

9 Figure 3: Connecting the VS-42UHD 4x2 HDMI Matrix Switcher 4.1 Connecting a Serial Controller via RS-232 To connect a serial controller to the VS-42UHD: • From the RS-232 9-pin D-sub serial port on the serial controller connect:  Pin 2 to the TX pin on the VS-42UHD RS-232 terminal block  Pin 3 to the RX pin on the VS-42UHD RS-232 terminal block  Pin 5 to the GND pin on the VS-42UHD RS-232 terminal block 4.2 Connecting to the VS-42UHD via Ethernet You can connect to the VS-42UHD via Ethernet using either of the following methods: • Directly to the PC using a crossover cable (see Section 4.2.1) • Via a network hub, switch, or router, using a straight-through cable (see Section 4.2.2)

VS-42UHD - Connecting the VS-42UHD

Note: If you want to connect via a router and your IT system is based on IPv6, speak to your IT department for specific installation instructions. 4.2.1 Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the VS-42UHD directly to the Ethernet port on your PC using a crossover cable with RJ-45 connectors. This type of connection is recommended for identifying the VS-42UHD with the factory configured default IP address. After connecting the VS-42UHD to the Ethernet port, configure your PC as follows: 1. Click Start > Control Panel > Network and Sharing Center. 2. Click Change Adapter Settings. 3. Highlight the network adapter you want to use to connect to the device and click Change settings of this connection. The Local Area Connection Properties window for the selected network adapter appears as shown in Figure 4. Figure 4: Local Area Connection Properties Window

VS-42UHD - Connecting the VS-42UHD

11 4. Highlight Internet Protocol Version 4 (TCP/IPv4) by clicking on the item. 5. Click Properties. The Internet Protocol Properties window appears as shown in Figure 5. Figure 5: Internet Protocol Version 4 Properties Window 6. Select Use the following IP Address for static IP addressing and fill in the details as shown in Figure 6. For TCP/IPv4 you can use any IP address in the range 192.168.1.1 to 192.168.1.255 (excluding 192.168.1.39) that is provided by your IT department.

VS-42UHD - Connecting the VS-42UHD

Figure 6: Internet Protocol Properties Window 7. Click OK. 8. Click Close. 4.2.2 Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the VS-42UHD to the Ethernet port on a network hub or using a straight-through cable with RJ-45 connectors. 4.3 Connecting the Remote Contact-Closure Switches You can connect up to four remote, contact-closure switches per output to control the VS-42UHD remotely. These switches replicate the Input selection buttons on the front panel of the VS-42UHD.

VS-42UHD - Connecting the VS-42UHD

13 Figure 7 illustrates the wiring of the switch connections to the terminal block. Figure 7: Remote Contact-closure Switch Connections

VS-42UHD - Principles of Operation

5 Principles of Operation This section describes the operating theory of the VS-42UHD and includes: • Automatic signal detection (see Section 5.1) • Input switching modes (see Section 5.2) • EDID operation (see Section 5.3) 5.1 Automatic Signal Detection The VS-42UHD can automatically detect the presence of a video signal on an input based on the presence of a video sync or clock signal. 5.2 Input Switching Modes 5.2.1 Manual Mode In Manual switching mode, routing is performed according to the front panel button selection or according to the remote command selection. 5.2.2 Automatic Mode Automatic switching can be performed in either of the following ways: • Input priority. Upon detection of an active input, the input with the highest priority is automatically selected. Input priority is from the lowest input number (1) to the highest (4) • Last Connected. The device automatically selects the most recently connected input. Should this source become inactive, the device automatically switches to the last connected input that was active. When turning the device on and more than one input is active, the input with the highest priority is selected If a manual selection is made when the device is in Automatic mode, the device enters Manual Override mode. The manually selected input remains selected as long as it is active. When a manually selected input becomes inactive, the device returns to Automatic mode.

VS-42UHD - Principles of Operation

15 5.3 EDID Operation The VS-42UHD has a default EDID (see Section 12) stored on all inputs. This EDID can be exchanged for either: • A custom EDID which is uploaded to one or more inputs using Protocol 3000 commands (see Section 13.3.5) –OR– • The EDID of a display device connected to an output by using either the front panel buttons (see Section 6.2), a Protocol 3000 command, or the Web pages The EDID is non-volatile and the last valid EDID is used when the device is powered up. 5.4 Step-in Functionality The VS-42UHD can function as a step-in switcher when connected to a suitable HDMI transmitter, (for example, the SID-X3N, DIP-30 or DIP-31) using the correct HDMI cable with HEC support. Use the Web pages (see Section 8.2.2) to assign remote device button actions. The default button actions are shown in the following table. Up to three buttons can be active at the same time. Command Action Echo Allows a connected controller to be programmed to perform a variety of tasks triggered by the user buttons, such as, room control, (lights, screen, and so on) Out1 Step in current input to Output 1 Out2 Step in current input to Output 2

VS-42UHD - Operating the VS-42UHD 4x2 HDMI Matrix Switcher

6 Operating the VS-42UHD 4x2 HDMI Matrix Switcher This section describes operating the VS-42UHD and consists of: • Switching an input to an output (see Section 6.1) • Acquiring an EDID from an output (see Section 6.2) • Muting and unmuting the outputs (see Section 6.3) • Locking and unlocking the front panel buttons (see Section 6.4) • Generating a test pattern (see Section 6.5) 6.1 Switching an Input to an Output To switch an input to an output, (for example, Input 4 to Output 2): • Press the Input 4 button in the bottom Output (To OUT 2) row. The LED lights red and Input 4 is switched to Output 2 6.2 Acquiring an EDID from an Output You can acquire the EDID from OUT 1 or OUT 2 and copy it to any or all of the four inputs to be stored in non-volatile memory. You can also reset any or all of the inputs to the default EDID. To copy the EDID from an Output to one or more Inputs: 1. Press the EDID button to enter the EDID setting mode. The EDID button lights. Note: If there is no button activity for 10 seconds, the device automatically exits the EDID setting mode to normal operation, the EDID button no longer lights and any changes made are lost. 2. From the To OUT 1 (top) row, press each of the Inputs to which you want to copy the EDID from Output 1. Each selected Input LED lights.

VS-42UHD - Operating the VS-42UHD 4x2 HDMI Matrix Switcher

17 3. From the To OUT 2 (bottom) row, press each of the Inputs into which you want to copy the EDID from Output 2. Each selected Input LED lights. 4. Press the EDID button. The button no longer lights and the EDID changes are saved. To copy the default EDID to one or more Inputs: 1. Press the EDID button to enter the EDID setting mode. The EDID button lights. 2. For each Input to which you want to copy the default EDID, press both the To OUT 1 and To OUT 2 buttons simultaneously. Both top row and bottom row Input LEDs light. 3. Press the EDID button. The button no longer lights and the EDID changes are saved. 6.3 Muting and Unmuting the Outputs To mute and unmute both outputs simultaneously: 1. Press the Mute button. The Mute button lights and the outputs are muted. 2. Press the lit Mute button. The outputs are unmuted and the button no longer lights. To mute and unmute one output: 1. Press the currently selected (and lit) input button. The output is muted and the button flashes. 2. Press the currently muted (and flashing) input button. The output is unmuted and the button lights solid.

VS-42UHD - Operating the VS-42UHD 4x2 HDMI Matrix Switcher

6.4 Locking and Unlocking the Front Panel Buttons To lock and unlock the front panel buttons: 1. Press and hold the Lock button. The front panel buttons are locked and the button lights. 2. Press and hold the Lock button again. The front panel buttons are unlocked and the button no longer lights. 6.5 Generating a Test Pattern For diagnostic purposes, the VS-42UHD can generate a number of test patterns on the outputs. Figure 8 shows the test patterns available. To generate a test pattern on the outputs: 1. Press the Function button. The button lights. 2. Press any of the Input buttons to select a test pattern. The selected test pattern is generated on the outputs. To exit the test pattern generator: • Press the lit Function button. The test pattern generation ceases and the button no longer lights. Figure 8: Available Test Patterns

VS-42UHD - Configuring and Maintaining the VS-42UHD

19 7 Configuring and Maintaining the VS-42UHD This section describes the configuration and maintenance of the VS-42UHD and consists of: • Setting the DIP-switches (see Section 7.1) • Resetting the device to factory default settings (see Section 7.2) • Upgrading the firmware (see Section 7.3) 7.1 Setting the DIP-Switches The DIP-switches dictate the behavior of the VS-42UHD. All DIP-switches are off by default. # Feature Description 1 HDCP support on inputs On—Disable HDCP support on all inputs Off—Enable HDCP support which is defined by P3000 commands 2 Video mode switching Output 1 On—Auto Off—Manual 3 Last connected/Priority mode Output 1 When DIP-switch 2 is set to Auto (ON): On—Enable Last Connected mode Off—Enable Priority mode where the priority of each input is defined by the input number, (1 is the highest priority) 4 Video mode switching Output 2 On—Auto Off—Manual 5 Last connected/Priority mode Output 2 When DIP-switch 4 is set to Auto (ON): On—Enable Last Connected mode Off—Enable Priority mode where the priority of each input is defined by the input number, (1 is the highest priority) 6 N/A – 7 N/A – 8 N/A –

VS-42UHD - Configuring and Maintaining the VS-42UHD

7.2 Resetting the VS-42UHD to Factory Default Settings To reset the device to factory default settings: 1. Power the device off. 2. Press and hold down the Reset button on the rear panel. 3. While holding down the Reset button, power on the device. 4. Wait a few seconds and release the button. The device is reset to its factory settings. 7.3 Upgrading the Firmware The VS-42UHD can be upgraded via any of the following: • Mini USB • RS-232 • Ethernet For instructions on upgrading the firmware see “K-Upload Software”.

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

21 8 Operating the VS-42UHD Remotely via the Web Pages The VS-42UHD can be operated remotely using the embedded Web pages. The Web pages are accessed using a Web browser and an Ethernet connection. Before attempting to connect: • Perform the procedures in Section 4.2 • Ensure that your browser is supported (see Section 10) • Ensure that JavaScript is enabled There are six Web pages: • Browsing and General Info (see Section 8.1) • Routing (see Section 8.2) • EDID (see Section 8.3) • Device Setting (see Section 8.4) • Firmware Update (see Section 8.5) • About Us (see Section 8.6) 8.1 Browsing the VS-42UHD Web Pages Note: In the event that a Web page does not update correctly, clear your Web browser’s cache (by pressing CTRL-F5). To browse the VS-42UHD Web pages: 1. Open your Internet browser. 2. Type the IP number of the device (see Section 4.2) in the Address bar of your browser.

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

The Loading page appears: Figure 9: The Loading Page Immediately after the Loading page, the General Info page appears which displays information related to the device and the Web page version. Figure 10: The General Info Page

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

23 8.2 Routing Page The VS-42UHD Routing page lets you perform operational actions, such as, switching inputs/outputs and selecting HDCP support. Figure 11: The Routing Page Item Description Output Buttons 1 and 2 2 Buttons for output selection, signal identification, and audio and video muting (see Section 8.2.1) Inputs Tab 6 Buttons for input selection, and port and signal identification (see Section 8.2.1) Patterns Button Tab 6 Buttons for video pattern generation (see Section 8.2.3)

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

Figure 12: The Output Buttons Item Description Output Button Number Identifies the Output number HDCP Indicator Indicates whether the Output port supports HDCP Video Mute Button Click the button to mute the video Signal Indicator Indicates whether or not there is a device connected to the output Mode Indicator Indicates the switching mode currently employed Figure 13: The Input Buttons

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

25 Item Description Input Button Number Identifies the Input number Input Type and Signal Indicator Indicates the type of input and whether there is a signal present on the Input HDCP Selection Button Click the button to turn HDCP support for the Input on and off HDCP Content Indicator Indicates whether or not the Input signal is HDCP protected Remote Device Control Button Click the button to display the control window for the remote device connected to this Input (see Section 8.2.2) 8.2.1 Switching an Input to an Output To switch an Input to an Output, (for example, Input 2 to Output 2): 1. Click on Output button 2. The button changes color to purple and the Output is selected. 2. Click on Input button 2. The button changes color to purple and the output is switched. 8.2.2 Controlling a Remote Transmitter Compatible remote transmitters, (for example, the SID-X3N, DIP-30 or DIP-31) that are connected to the VS-42UHD can be controlled using the Web pages, (see Section 8.2, Figure 13). Figure 14: The Remote Device Control Window

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

The VS-42UHD allows you to program the general purpose buttons on remote modules. The table shows the functionality defined for each button. The options are: • HDMI—selects one of the four inputs • Echo—allows a connected controller to be programmed to perform a variety of tasked triggered by the user buttons, such as, room control, (lights, screen, and so on) • Out 1—step-in current input to output 1 • Out 2—step-in current input to output 2 Note: These settings are per input and remain valid even if the remote SID-X3N is exchanged for another SID-X3N. Up to three of the Echo, Out 1 and Out 2 buttons can be active at the same time. 8.2.3 Using Test Patterns as Video Inputs You can use one of four built-in, video test patterns as a video Input. Figure 15: Test Pattern Tab

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

27 To select a test pattern as an Input for an Output: 1. Click the Patterns tab. The four test pattern buttons are shown. 2. Click the required Output to select it. The button changes color. 3. Click the required test pattern button. The button changes color and the selected test pattern is switched to the Output. 8.3 EDID Page The VS-42UHD EDID page lets you copy EDID data to one or more Inputs from an: • Output • Input • EDID data file Figure 16: The EDID Page

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

Note: The display is not updated automatically when the status of an EDID changes on the device due to outputs being exchanged. Click Refresh to update the display. To copy EDID data from an Output or Input to one or more inputs: 1. Click the source button from which to copy the EDID (Output or Input). The button changes color and the EDID summary information reflects the EDID data. 2. Click one or more destination Inputs, or select all Inputs by checking the Inputs check-box. All selected Input buttons change color and the EDID summary information reflects the Input selection(s). 3. Click the Copy button. The “EDID was copied” success message is displayed and the EDID data are copied to the selected Input(s). 4. Click OK. To copy EDID data to an Input from an EDID data file: 1. Click the source Browse button. The Windows Browser opens. 2. Browse to the required file. 3. Select the required file and click Open. The EDID summary information reflects the selection. 4. Click one or more destination Inputs, or select all Inputs by checking the Inputs check-box. All selected Input buttons change color and the EDID summary information reflects the Input selection(s). 5. Click the Copy button. The “EDID was copied” success message is displayed and the EDID data are copied to the selected Input(s).

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

29 6. Click OK. 8.4 Device Setting Page The VS-42UHD Device Settings page lets you modify some communication parameters and view others. Figure 17: The Device Setting Page To modify serial or Ethernet communication parameters: 1. Adjust the parameters as required, either by entering the parameters directly or by using the drop-down list. 2. Click Set. The changes are saved.

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

8.5 Firmware Upgrade Page The Firmware Upgrade page lets you perform a firmware upgrade from a firmware file. Figure 18: The Firmware Upgrade Page To upgrade the firmware: 1. Click the Choose File button. The Windows Browser opens. 2. Browse to the required file. 3. Select the required file and click Open. The firmware file name is displayed in the Firmware Upgrade page. 4. Click Start Upgrade. The firmware file is loaded and a progress bar is displayed. Do not interrupt the process or the VS-42UHD may be damaged. 5. When the process is complete reboot the device. The firmware is upgraded.

VS-42UHD - Operating the VS-42UHD Remotely via the Web Pages

31 8.6 About Us Page The VS-42UHD About Us page displays the Web page version and Kramer Electronics Ltd company details. Figure 19: The About Us Page

VS-42UHD - Wiring the Twisted Pair RJ-45 Connectors

9 Wiring the Twisted Pair RJ-45 Connectors Connect/solder the cable shield to the RJ-45 connector shield. Do not use a crossed TP cable with this product. Using a TP cable that is incorrectly wired may cause permanent damage to the device Do not use unshielded TP cables with this product The following figure defines the TP pinout using a straight pin-to-pin cable with RJ-45 connectors. EIA /TIA 568B Pin Wire Color 1 Orange / White 2 Orange 3 Green / White 4 Blue 5 Blue / White 6 Green 7 Brown / White 8 Brown Pair 1 4 and 5 Pair 2 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Figure 20: TP Pinout Wiring

VS-42UHD - Technical Specifications

33 10 Technical Specifications INPUTS: 4 HDMI Connectors OUTPUTS: 2 HDMI Connectors PORTS: 1 Ethernet on an RJ-45 connector 1 IR on a 3.5mm mini jack 12 Remote selection contact-closure switches on 13 terminal block pins 1 Serial port on a 3-pin terminal block 1 Program port on a mini USB BANDWIDTH: Up to 8.91Gbps data rate (2.97Gbps per graphic channel) COMPLIANCE WITH HDMI STANDARD: HDMI and HDCP RESOLUTION: Up to UXGA; 4K x 2K SUPPORTED BAUD RATES: 9600, 115200bps SUPPORTED WEB BROWSERS: The following operating systems and Web browsers are supported: Windows 7: • Google Chrome v25 • FireFox v15 • Opera v12 • Microsoft Internet Explorer v9 Windows XP: • Google Chrome v25 • FireFox v15 Apple Mac: • Google Chrome v25 • FireFox v20 • Opera v12.14 • Safari v6 POWER CONSUMPTION: 5V DC, 880mA CONTROLS: Front panel buttons, infrared remote control transmitter, RS-232, Ethernet, Remote input selection switches OPERATING TEMPERATURE: 0° to +40°C (32° to 104°F) STORAGE TEMPERATURE: -40° to +70°C (-40° to 158°F) HUMIDITY: 10% to 90%, RHL non-condensing POWER CONSUMPTION: 100-240V AC, 65VA max. DIMENSIONS: 21.5cm x 16.6cm x 4.4cm (8.46" x 6.54" x 1.73") W, D, H WEIGHT: 0.9kg (2.0lbs) approx. SHIPPING DIMENSIONS: 35.1cm x 21.2cm x 7.2cm (13.8" x 8.4" x 2.8") W, D, H SHIPPING WEIGHT: 1.6kg (3.5lbs) approx. INCLUDED ACCESSORIES: Power supply, RC-IR3 remote control OPTIONS: External remote IR receiver cable, RK-1 Specifications are subject to change without notice For the most updated resolution list, go to our Web site at www.kramerav.com

VS-42UHD - Default Communication Parameters

11 Default Communication Parameters RS-232 Protocol 3000 Baud Rate: 115,200 Data Bits: 8 Stop Bits: 1 Parity: None Command Format: ASCII TCP/IP Parameters IP Address: 192.168.1.39 Netmask: 255.255.0.0 Gateway: 0.0.0.0 TCP Port #: 5000 UDP Port #: 50000

VS-42UHD - Default EDID

35 12 Default EDID Monitor #1 [Real-time 0x0100] Model name............... DELL U2410 Manufacturer............. Dell Plug and Play ID......... DELF015 Serial number............ F525M0562VNL Manufacture date......... 2010, ISO week 19 Filter driver............ None ------------------------- EDID revision............ 1.3 Input signal type........ Digital Color bit depth.......... Undefined Display type............. RGB color Screen size.............. 520 x 320 mm (24.0 in) Power management......... Standby, Suspend, Active off/sleep Extension blocs.......... None ------------------------- DDC/CI................... Supported MCCS revison............. 2.0 Display technology....... TFT Controller............... Genesis 0x10000 Firmware revision........ 9.1 Firmware flags........... 0x006645CC Active power on time..... Not supported Power consumption........ Not supported Current frequency........ 74.10kHz, 60.00Hz Color characteristics Default color space...... sRGB Display gamma............ 2.20 Red chromaticity......... Rx 0.680 - Ry 0.310 Green chromaticity....... Gx 0.206 - Gy 0.693 Blue chromaticity........ Bx 0.151 - By 0.055 White point (default).... Wx 0.313 - Wy 0.329 Additional descriptors... None Timing characteristics Horizontal scan range.... 30-81kHz Vertical scan range...... 56-76Hz Video bandwidth.......... 170MHz CVT standard............. Not supported GTF standard............. Not supported Additional descriptors... None Preferred timing......... Yes Native/preferred timing.. 1920x1200p at 60Hz (16:10) Modeline............... "1920x1200" 154.000 1920 1968 2000 2080 1200 1203 1209 1235 +hsync -vsync Standard timings supported 720 x 400p at 70Hz - IBM VGA 640 x 480p at 60Hz - IBM VGA 640 x 480p at 75Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 75Hz - VESA 1024 x 768p at 60Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1280 x 1024p at 60Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1920 x 1200p at 60Hz - VESA STD 1152 x 864p at 75Hz - VESA STD Report information Date generated........... 8/11/2016 Software revision........ 2.60.0.972 Data source.............. Real-time 0x0100 Operating system......... 6.1.7601.2.Service Pack 1 Raw data 00,FF,FF,FF,FF,FF,FF,00,10,AC,15,F0,4C,4E,56,32,13,14,01,03,80,34,20,78,EE,1E,C5,AE,4F,34,B1,26, 0E,50,54,A5,4B,00,81,80,A9,40,D1,00,71,4F,01,01,01,01,01,01,01,01,28,3C,80,A0,70,B0,23,40,30,20, 36,00,06,44,21,00,00,1A,00,00,00,FF,00,46,35,32,35,4D,30,35,36,32,56,4E,4C,0A,00,00,00,FC,00,44, 45,4C,4C,20,55,32,34,31,30,0A,20,20,00,00,00,FD,00,38,4C,1E,51,11,00,0A,20,20,20,20,20,20,00,39 ---------------------------

VS-42UHD - Default EDID

Monitor #2 [Real-time 0x1300] Model name............... DELL U2410 Manufacturer............. Dell Plug and Play ID......... DELF015 Serial number............ F525M2ARAE4L Manufacture date......... 2012, ISO week 43 Filter driver............ None ------------------------- EDID revision............ 1.3 Input signal type........ Digital Color bit depth.......... Undefined Display type............. RGB color Screen size.............. 520 x 320 mm (24.0 in) Power management......... Standby, Suspend, Active off/sleep Extension blocs.......... None ------------------------- DDC/CI................... Supported MCCS revison............. 2.0 Display technology....... TFT Controller............... Genesis 0x10000 Firmware revision........ 17.1 Firmware flags........... 0x006645CC Active power on time..... Not supported Power consumption........ Not supported Current frequency........ 73.90kHz, 59.80Hz Color characteristics Default color space...... sRGB Display gamma............ 2.20 Red chromaticity......... Rx 0.680 - Ry 0.310 Green chromaticity....... Gx 0.206 - Gy 0.693 Blue chromaticity........ Bx 0.151 - By 0.055 White point (default).... Wx 0.313 - Wy 0.329 Additional descriptors... None Timing characteristics Horizontal scan range.... 30-81kHz Vertical scan range...... 56-76Hz Video bandwidth.......... 170MHz CVT standard............. Not supported GTF standard............. Not supported Additional descriptors... None Preferred timing......... Yes Native/preferred timing.. 1920x1200p at 60Hz (16:10) Modeline............... "1920x1200" 154.000 1920 1968 2000 2080 1200 1203 1209 1235 +hsync -vsync Standard timings supported 720 x 400p at 70Hz - IBM VGA 640 x 480p at 60Hz - IBM VGA 640 x 480p at 75Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 75Hz - VESA 1024 x 768p at 60Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1280 x 1024p at 60Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1920 x 1200p at 60Hz - VESA STD 1152 x 864p at 75Hz - VESA STD Report information Date generated........... 8/11/2016 Software revision........ 2.60.0.972 Data source.............. Real-time 0x1300 Operating system......... 6.1.7601.2.Service Pack 1 Raw data 00,FF,FF,FF,FF,FF,FF,00,10,AC,15,F0,4C,34,45,41,2B,16,01,03,80,34,20,78,EE,1E,C5,AE,4F,34,B1,26, 0E,50,54,A5,4B,00,81,80,A9,40,D1,00,71,4F,01,01,01,01,01,01,01,01,28,3C,80,A0,70,B0,23,40,30,20, 36,00,06,44,21,00,00,1A,00,00,00,FF,00,46,35,32,35,4D,32,41,52,41,45,34,4C,0A,00,00,00,FC,00,44, 45,4C,4C,20,55,32,34,31,30,0A,20,20,00,00,00,FD,00,38,4C,1E,51,11,00,0A,20,20,20,20,20,20,00,2D ---------------------------

VS-42UHD - Default EDID

37 Monitor #3 [Real-time 0x2500] Model name............... VS-42UHD Manufacturer............. KMR Plug and Play ID......... KMR1200 Serial number............ 505-709990100 Manufacture date......... 2011, ISO week 255 Filter driver............ None ------------------------- EDID revision............ 1.3 Input signal type........ Digital Color bit depth.......... Undefined Display type............. RGB color Screen size.............. 520 x 320 mm (24.0 in) Power management......... Standby, Suspend, Active off/sleep Extension blocs.......... 1 (Reserved - 0x00) ------------------------- DDC/CI................... Not supported Color characteristics Default color space...... Non-sRGB Display gamma............ 2.20 Red chromaticity......... Rx 0.674 - Ry 0.319 Green chromaticity....... Gx 0.188 - Gy 0.706 Blue chromaticity........ Bx 0.148 - By 0.064 White point (default).... Wx 0.313 - Wy 0.329 Additional descriptors... None Timing characteristics Horizontal scan range.... 30-83kHz Vertical scan range...... 56-76Hz Video bandwidth.......... 170MHz CVT standard............. Not supported GTF standard............. Not supported Additional descriptors... None Preferred timing......... Yes Native/preferred timing.. 1280x720p at 60Hz (16:10) Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync Standard timings supported 720 x 400p at 70Hz - IBM VGA 720 x 400p at 88Hz - IBM XGA2 640 x 480p at 60Hz - IBM VGA 640 x 480p at 67Hz - Apple Mac II 640 x 480p at 72Hz - VESA 640 x 480p at 75Hz - VESA 800 x 600p at 56Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 72Hz - VESA 800 x 600p at 75Hz - VESA 832 x 624p at 75Hz - Apple Mac II 1024 x 768i at 87Hz - IBM 1024 x 768p at 60Hz - VESA 1024 x 768p at 70Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1152 x 870p at 75Hz - Apple Mac II 1280 x 1024p at 75Hz - VESA STD 1280 x 1024p at 85Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1024 x 768p at 85Hz - VESA STD 800 x 600p at 85Hz - VESA STD 640 x 480p at 85Hz - VESA STD 1152 x 864p at 70Hz - VESA STD 1280 x 960p at 60Hz - VESA STD Report information Date generated........... 8/11/2016 Software revision........ 2.60.0.972 Data source.............. Real-time 0x2500 Operating system......... 6.1.7601.2.Service Pack 1 Raw data 00,FF,FF,FF,FF,FF,FF,00,2D,B2,00,12,01,01,01,01,FF,15,01,03,80,34,20,78,EA,B3,25,AC,51,30,B4,26, 10,50,54,FF,FF,80,81,8F,81,99,A9,40,61,59,45,59,31,59,71,4A,81,40,01,1D,00,72,51,D0,1E,20,6E,28, 55,00,07,44,21,00,00,1E,00,00,00,FF,00,35,30,35,2D,37,30,39,39,39,30,31,30,30,00,00,00,FC,00,56, 53,2D,34,32,55,48,44,00,00,00,00,00,00,00,00,FD,00,38,4C,1E,53,11,00,0A,20,20,20,20,20,20,01,5D ---------------------------

VS-42UHD - Default EDID

Hardware data BUS_SLOT = PCI00000.PCI00004.PCI00008.PCI0000C.PCI00010.PCI00014.PCI00018.PCI0001C 00000000 = 01508086.20900006.06000009.00000000.00000000.00000000.00000000.00000000 00000008 = 01518086.00100007.06040009.00810010.00000000.00000000.00010100.2000E0E0 00000010 = 01528086.00900407.03800009.00000000.F7400004.00000000.D000000C.00000000 000000A0 = 1E318086.02900406.0C033004.00000000.F7A20004.00000000.00000000.00000000 000000B0 = 1E3A8086.00100006.07800004.00800000.F7A3C004.00000000.00000000.00000000 000000B3 = 1E3D8086.00B00400.07000204.00000000.0000F0E1.F7A3A000.00000000.00000000 000000C8 = 15028086.00100406.02000004.00000000.F7A00000.F7A39000.00000001.00000000 000000D0 = 1E2D8086.02900006.0C032004.00000000.F7A38000.00000000.00000000.00000000 000000D8 = 1E208086.00100006.04030004.00000010.F7A30004.00000000.00000000.00000000 000000E0 = 1E108086.00100004.060400C4.00810010.00000000.00000000.00020200.200000F0 000000E8 = 1E268086.02900006.0C032004.00000000.F7A37000.00000000.00000000.00000000 000000F0 = 244E8086.00100007.060401A4.00010000.00000000.00000000.20040400.2280C0C0 000000F8 = 1E478086.02100007.06010004.00800000.00000000.00000000.00000000.00000000 00000100 = 118710DE.00100007.030000A1.00800010.F6000000.E000000C.00000000.E800000C 00000101 = 0E0A10DE.00100006.040300A1.00800010.F7080000.00000000.00000000.00000000 00000300 = 10D38086.00100406.02000000.00000010.F7900000.00000000.00000001.F7920000 00000400 = 98359710.02800001.07800001.00002010.0000C051.0000C041.0000C031.0000C021 00000418 = 581111C1.02900006.0C001070.00002010.F7800000.00000000.00000000.00000000 --------

VS-42UHD - Protocol 3000

39 13 Protocol 3000 The VS-42UHD can be operated using the Kramer Protocol 3000 serial commands. The command framing varies according to how you interface with the VS-42UHD. For example, a basic video input switching command that routes a layer 1 video signal to HDMI out 1 from HDMI input 2 (ROUTE 1,1,2), is entered as follows: • Terminal communication software, such as Hercules: The framing of the command varies according to the terminal communication software. • K-Touch Builder (Kramer software):

VS-42UHD - Protocol 3000

• K-Config (Kramer configuration software): All the examples provided in this section are based on using the K-Config software. You can enter commands directly using terminal communication software (e.g., Hercules) by connecting a PC to the serial or Ethernet port on the VS-42UHD. To enter CR press the Enter key (LF is also sent but is ignored by the command parser). Commands sent from various non-Kramer controllers (e.g., Crestron) may require special coding for some characters (such as, /X##). For more information, refer to your controller’s documentation. For more information about: • Understanding Protocol 3000, see Section 13.1 • General syntax used for Protocol 3000 commands, see Section 13.2 • Protocol 3000 commands available for the VS-42UHD, see Section 13.3 13.1 Understanding Protocol 3000 Protocol 3000 commands are structured according to the following: • Command – A sequence of ASCII letters (A-Z, a-z and -). A command and its parameters must be separated by at least one space. • Parameters – A sequence of alphanumeric ASCII characters (0-9, A-Z, a-z and some special characters for specific commands). Parameters are separated by commas. • Message string – Every command entered as part of a message string begins with a message starting character and ends with a message closing character.

VS-42UHD - Protocol 3000

41 A string can contain more than one command. Commands are separated by a pipe (|) character. The maximum string length is 64 characters. • Message starting character:  # – For host command/query  ~ – For device response • Device address – K-NET Device ID followed by @ (optional, K-NET only) • Query sign – ? follows some commands to define a query request • Message closing character:  CR – Carriage return for host messages (ASCII 13)  CR LF – Carriage return for device messages (ASCII 13) and line-feed (ASCII 10) • Command chain separator character – Multiple commands can be chained in the same string. Each command is delimited by a pipe character (|). When chaining commands, enter the message starting character and the message closing character only at the beginning and end of the string. Spaces between parameters or command terms are ignored. Commands in the string do not execute until the closing character is entered. A separate response is sent for every command in the chain.

VS-42UHD - Protocol 3000

13.2 Kramer Protocol 3000 Syntax The Kramer Protocol 3000 syntax uses the following delimiters: • CR = Carriage return (ASCII 13 = 0x0D) • LF = Line feed (ASCII 10 = 0x0A) • SP = Space (ASCII 32 = 0x20) Some commands have short name syntax in addition to long name syntax to enable faster typing. The response is always in long syntax. The Protocol 3000 syntax is in the following format: • Host Message Format: Start Address (optional) Body Delimiter # Device_id@ Message CR • Simple Command – Command string with only one command without addressing: Start Body Delimiter # Command SP Parameter_1,Parameter_2,… CR • Command String – Formal syntax with command concatenation and addressing: Start Address Body Delimiter # Device_id@ Command_1 Parameter1_1,Parameter1_2,…| Command_2 Parameter2_1,Parameter2_2,…| Command_3 Parameter3_1,Parameter3_2,…|… CR • Device Message Format: Start Address (optional) Body Delimiter ~ Device_id@ Message CR LF • Device Long Response – Echoing command: Start Address (optional) Body Delimiter ~ Device_id@ Command SP [Param1 ,Param2 …] result CR LF

VS-42UHD - Protocol 3000

43 13.3 Protocol 3000 Commands This section includes the following commands: • System Commands (see Section 13.3.1) • Switching/Routing Commands (see Section 13.3.2) • Video Commands (see Section 13.3.3) • Communication Commands (see Section 13.3.4) • EDID Handling Commands (see Section 13.3.5) 13.3.1 System Commands Command Description # Protocol handshaking (system mandatory) BUILD-DATE Get device build date (system mandatory) FACTORY Reset to factory default configuration HELP Get command list (system mandatory) LOCK-FP Set/get front panel lock MODEL Get device model (system mandatory) PROT-VER Get device protocol version (system mandatory) RESET Reset device (system mandatory) SN Get device serial number (system mandatory) VERSION Get device firmware version (system mandatory) DISPLAY Get output HPD status (system) HDCP-MOD Set/get HDCP mode (system) HDCP-STAT Get HDCP signal status (system) NAME Set/get machine (DNS) name (system – Ethernet) NAME-RST Reset machine (DNS) name to factory default (system – Ethernet) PRIO? Get priority for an input (system) SIGNAL Get input signal lock status (system)

VS-42UHD - Protocol 3000

13.3.1.1 # Functions Permission Transparency Set: # End User Public Get: - - - Description Syntax Set: Protocol handshaking #CR Get: - - Response ~nn@SPOKCR LF Parameters Response Triggers Notes Validates the Protocol 3000 connection and gets the machine number Step-in master products use this command to identify the availability of a device K-Config Example “#”,0x0D 13.3.1.2 BUILD-DATE Functions Permission Transparency Set: - - - Get: BUILD-DATE? End User Public Description Syntax Set: - - Get: Get device build date #BUILD-DATE?CR Response ~nn@BUILD-DATESPdateSPtimeCR LF Parameters date – Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day time – Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds Response Triggers Notes K-Config Example “#BUILD-DATE?”,0x0D

VS-42UHD - Protocol 3000

45 13.3.1.3 FACTORY Functions Permission Transparency Set: FACTORY End User Public Get: - - - Description Syntax Set: Reset device to factory default configuration #FACTORYCR Get: - - Response ~nn@FACTORYSPOKCR LF Parameters Response Triggers Notes This command deletes all user data from the device. The deletion can take some time. Your device may require powering off and powering on for the changes to take effect. K-Config Example “#FACTORY”,0x0D 13.3.1.4 HELP Functions Permission Transparency Set: - - - Get: HELP End User Public Description Syntax Set: - - Get: Get command list or help for specific command 1. #HELPCR 2. #HELPSPCOMMAND_NAMECR Response 1. Multi-line: ~nn@Device available protocol 3000 commands:CR LFcommand,SP command...CR LF 2. Multi-line: ~nn@HELPSPcommand:CR LFdescriptionCR LFUSAGE:usageCR LF Parameters COMMAND_NAME – name of a specific command Response Triggers Notes To get help for a specific command use: HELPSPCOMMAND_NAMECR LF K-Config Example “#HELP”,0x0D

VS-42UHD - Protocol 3000

13.3.1.5 LOCK-FP Functions Permission Transparency Set: LOCK-FP End User Public Get: LOCK-FP? End User Public Description Syntax Set: Set front panel lock Option 1: #LOCK-FP␠lock_mode␍ Get: Get front panel lock state Option 1: #LOCK-FP?␍ Response Set: ~nn@LOCK-FP␠lock_mode␠OK␍␊ Get: ~nn@LOCK-FP␠lock_mode␍␊ Parameters lock_mode - 0/OFF - unlocks the front panel buttons, 1/ON - locks the front panel buttons Response Triggers Notes Lock the front panel buttons: “#LOCK-FP 1”,0x0D

VS-42UHD - Protocol 3000

47 13.3.1.6 MODEL Functions Permission Transparency Set: - - - Get: MODEL? End User Public Description Syntax Set: - - Get: Get device model #MODEL?CR Response ~nn@MODELSPmodel_nameCR LF Parameters model_name – String of up to 19 printable ASCII chars Response Triggers Notes This command identifies equipment connected to Step-in master products and notifies of identity changes to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests K-Config Example “#MODEL?”,0x0D 13.3.1.7 PROT-VER Functions Permission Transparency Set: - - - Get: PROT-VER? End User Public Description Syntax Set: - - Get: Get device protocol version #PROT-VER?CR Response ~nn@PROT-VERSP3000:versionCR LF Parameters version - XX.XX where X is a decimal digit Response Triggers Notes K-Config Example “#PROT-VER?”,0x0D

VS-42UHD - Protocol 3000

13.3.1.8 RESET Functions Permission Transparency Set: RESET Administrator Public Get: - - - Description Syntax Set: Reset device #RESETCR Get: - - Response ~nn@RESETSPOKCR LF Parameters Response Triggers Notes To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the port was locked, disconnect and reconnect the cable to reopen the port. K-Config Example “#RESET”,0x0D 13.3.1.9 SN Functions Permission Transparency Set: - - - Get: SN? End User Public Description Syntax Set: - - Get: Get device serial number #SN?CR Response ~nn@SNSPserial_numberCR LF Parameters serial_number – 11 decimal digits, factory assigned Response Triggers Notes This device has a 14 digit serial number, only the last 11 digits are displayed K-Config Example “#SN?”,0x0D

VS-42UHD - Protocol 3000

49 13.3.1.10 VERSION Functions Permission Transparency Set: - - - Get: VERSION? End User Public Description Syntax Set: - - Get: Get firmware version number #VERSION?CR Response ~nn@VERSIONSPfirmware_versionCR LF Parameters firmware_version – XX.XX.XXXX where the digit groups are: major.minor.build version Response Triggers Notes K-Config Example “#VERSION?”,0x0D 13.3.1.11 DISPLAY Functions Permission Transparency Set: - - - Get DISPLAY? End User Public Description Syntax Set: - - Get: Get output HPD status #DISPLAY?SPout_idCR Response ~nn@DISPLAYSPout_id,statusCR LF Parameters out_id – 1 (HDMI Out) status – HPD status according to signal validation : 0 (Off), 1 (On), 2 (On and all parameters are stable and valid) Response Triggers A response is sent to the com port from which the Get was received, after command execution and: After every change in output HPD status from On to Off (0) After every change in output HPD status from Off to On (1) After every change in output HPD status form Off to On and all parameters (new EDID, etc.) are stable and valid (2) Notes K-Config Example Get the output HPD status of HDMI Out: “#DISPLAY? 1”,0x0D

VS-42UHD - Protocol 3000

13.3.1.12 HDCP-MOD Functions Permission Transparency Set: HDCP-MOD Administrator Public Get: HDCP-MOD? End User Public Description Syntax Set: Set HDCP mode #HDCP-MODSPinp_id,modeCR Get: Get HDCP mode #HDCP-MOD?SPinp_idCR Response Set / Get: ~nn@HDCP-MODSPinp_id,modeCR LF Parameters inp_id – input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) mode – HDCP mode: 0 (HDCP Off), 3 (Mirror output – MAC mode) Response Triggers A response is sent to the com port from which the set (before execution) / get command was received A response is sent to all com ports after command execution if HDCP-MOD was set by any other external control device (device button, device menu or other) or if the HDCP mode changed Notes Set HDCP working mode on the device input: HDCP not supported - HDCP Off HDCP support changes following detected sink - MIRROR OUTPUT K-Config Example Disable HDCP mode on HDMI In 2: “#HDCP-MOD 2,0”,0x0D

VS-42UHD - Protocol 3000

51 13.3.1.13 HDCP-STAT Functions Permission Transparency Set: - - - Get: HDCP-STAT? End User Public Description Syntax Set: - - Get: Get HDCP signal status #HDCP-STAT?SPstage,stage_idCR Response ~nn@HDCP-STATSPstage,stage_id,statusCR LF Parameters stage – 0 (input), 1 (output) stage_id – for input stage: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) for output stage: 1 (HDMI 1 Out), 2 (HDMI 2 Out) status – signal encryption status: 0 (On), 1 (Off) Response Triggers A response is sent to the com port from which the Get command was received Notes Output stage (1) – get the HDCP signal status of the sink device connected to HDMI Out Input stage (0) – get the HDCP signal status of the source device connected to the specified input K-Config Example Get the HDCP input signal status of the source device connected to HDMI In 1: “#HDCP-STAT? 0,1”,0x0D

VS-42UHD - Protocol 3000

13.3.1.14 NAME Functions Permission Transparency Set: NAME Administrator Public Get: NAME? End User Public Description Syntax Set: Set machine (DNS) name #NAMESPmachine_nameCR Get: Get machine (DNS) name #NAME?CR Response Set: ~nn@NAMESPmachine_nameCR LF Get: ~nn@NAME?SPmachine_nameCR LF Parameters machine_name - String of up to 14 alpha-numeric characters (can include hyphens but not at the beginning or end) Response Triggers Notes The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use (with DNS feature on). K-Config Example Set the DNS name of the device to “room-442”: “#NAME room-442”,0x0D 13.3.1.15 NAME-RST Functions Permission Transparency Set: NAME-RST Administrator Public Get: - - - Description Syntax Set: Reset machine (DNS) name to factory default #NAME-RSTCR Get: - - Response ~nn@NAME-RSTSPOKCR LF Parameters Response Triggers Notes Factory default of machine (DNS) name is “KRAMER_” K-Config Example Reset the DNS name of the device to the factory default: “#NAME-RST”,0x0D

VS-42UHD - Protocol 3000

53 13.3.1.16 PRIO Functions Permission Transparency Set: – – – Get PRIO? Administrator Public Description Syntax Set: – – Get: Get input priority #PRIO?SPinput_idCR Response ~nn@PRIOSPinput_id,prioCR LF Parameters input_id - input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) prio - assigned priority (1.. max priority) Response triggers After execution, response is sent to the com port from which the command was received After execution, response is sent to all com ports if PRIO was set by any other external control device (button press, device menu and similar) Notes The PRIO max value may vary for different devices K-Config Example Get the input priority of HDMI In 2: “#PRIO? 2”,0x0D

VS-42UHD - Protocol 3000

13.3.1.17 SIGNAL Functions Permission Transparency Set: - - - Get SIGNAL? End User Public Description Syntax Set: - - Get: Get input signal lock status #SIGNAL?SPinp_idCR Response ~nn@SIGNALSPinp_id,statusCR LF Parameters inp_id – input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) status – lock status according to signal validation: 0 (Off), 1 (On) Response Triggers After execution, a response is sent to the com port from which the Get was received A response is sent after every change in input signal status from On to Off or from Off to On Notes K-Config Example Get the input signal lock status of HDMI In 2: “#SIGNAL? 2”,0x0D

VS-42UHD - Protocol 3000

55 13.3.2 Switching/Routing Commands Command Description MTX-MODE? Get switch mode ROUTE Set/get layer routing VID Set/get video switch state 13.3.2.1 MTX-MODE Functions Permission Transparency Set: – – – Get: MTX-MODE? End User Public Description Syntax Set: – – Get : Get auto-switch mode #MTX-MODE?SPoutput_idCR Response ~nn@MTX-MODESPoutput_id,modeCR Parameters output_id: 1 (Out1), 2 (Out2) mode - 0 (manual), 1 (auto priority), 2 (auto last connected) Response Triggers After execution, a response is sent to the com port from which the Get was received After execution, a response is sent to all com ports if MTX-MODE was set by any other external control device (button press, WEB, device menu and similar) K-Config Example Get auto switch mode of Out 2: “#MTX-MODE? 2,0”,0x0D

VS-42UHD - Protocol 3000

13.3.2.2 ROUTE Functions Permission Transparency Set: ROUTE End User Public Get: ROUTE? End User Public Description Syntax Set: Set layer routing #ROUTESPlayer,dest,srcCR Get: Get layer routing #ROUTE?SPlayer,destCR Response ~nn@ROUTESPlayer,dest,srcCR LF Parameters layer – 1 (video) dest – for video layer: 1 (HDMI Out 1), 2 (HDMI Out 2) src – for video layer: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) Response Triggers Notes The get command identifies input switching on Step-in clients The set command is for remote input switching on Step-in clients (essentially via by the Web) K-Config Example Set the remote input switching of HDMI In 3 to HDMI Out 1: “#ROUTE 1,1,3”,0x0D

VS-42UHD - Protocol 3000

57 13.3.2.3 VID Functions Permission Transparency Set: VID End User Public Get: VID? End User Public Description Syntax Set: Set video switch state #VIDSPin>outCR Get: Get video switch state #VID?SPoutCR Response Set: ~nn@VIDSPin>outCR LF Get: ~nn@VIDSPin>outCR LF Parameters in – input number: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4) > – connection character between in and out parameters out – output number: 1 (HDMI Out 1), 2 (HDMI Out 2), * (for all outputs) Response Triggers Notes K-Config Example Set the video switch state from HDMI In 4 to HDMI Out 2: “#VID 4>1”,0x0D

VS-42UHD - Protocol 3000

13.3.3 Video Commands Command Description DEF-RES Set/get custom defined scaled video output resolution to “VIC” index VID-PATTERN Set/get video test pattern VMUTE Set/get video on output mute 13.3.3.1 DEF-RES Functions Permission Transparency Set – – – Get DEF-RES? End User Public Description Syntax Set: – – Get: Get custom defined video resolution #DEF-RES?SPTable_id,stage,stage_idCR Response ~nn@DEF-RESSP Table_id,Width,Height,Htotal,VTotal,HSyncW,HSyncBackPorch,VSyncW,VSyncBackPorch, FrRate,InterlacedCR LF Parameters Table_id – 2 (HDMI) Stage – 0 (input), 1 (output) Stage_id – for input stage: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4), for output stage: 1 (HDMI Out 1), 2 (HDMI Out 2) Response Triggers After execution, response is sent to the com port from which the Set/Get was received After execution, response is sent to all com ports if DEF-RES was set by any other external control device (button press, device menu and similar) Notes If a requested custom resolution is not defined, yet is in the device, it returns ERRSP003 (out of range) Only indexes 100-104 are valid for custom defined resolution In Get command when sending: index 0 - device replies with detailed info of native resolution index 255 - device replies with detailed info of current resolution K-Config Example Get the detailed custom defined resolution from HDMI Out 2: “#DEF-RES? 255,0,2”,0x0D

VS-42UHD - Protocol 3000

59 13.3.3.2 VID-PATTERN Functions Permission Transparency Set: VID-PATTERN End User Public Get: VID-PATTERN? End User Public Description Syntax Set: Set test pattern on output #VID-PATTERNSPoutput_id,pattern_idCR Get : Get test pattern on output #VID-PATTERN?SPoutput_idCR Response ~nn@VID-PATTERNSPoutput_id,pattern_idCR Parameters output_id - 1 (HDMI Out 1), 2 (HDMI Out 2) pattern_id - 1 (Pattern 1: vertical color bars), 2 (Pattern 2: checkerboard), 3 (Pattern 3: gradient), 4 (Pattern 4: white) Response Triggers After execution, response is sent to the com port from which the Set/Get was received After execution, response is sent to all com ports if VID-PATTERN was set by any other external control device (button press, WEB, device menu and similar) Notes K-Config Example Set HDMI Out 2 to pattern 2 (checkerboard): “#VID-PATTERN,2,2”,0x0D 13.3.3.3 VMUTE Functions Permission Transparency Set: VMUTE End User Public Get: VMUTE? End User Public Description Syntax Set: Set enable/disable video on output #VMUTESPoutput_id,flagCR Get: Get video on output status #VMUTE?SPoutput_idSP CR Response Set / Get: ~nn@VMUTESPoutput_id,flagCR LF Parameters output_id – 1 (HDMI Out) flag – 0 (disable video on output), 1 (enable video on output), 2 (blank video) Response Triggers K-Config Example Disable the video output on HDMI Out: “#VMUTE 2,0”,0x0D

VS-42UHD - Protocol 3000

13.3.4 Communication Commands Command Description ETH-PORT Set/get Ethernet port protocol NET-DHCP Set/get DHCP mode NET-GATE Set/get gateway IP NET-IP Set/get IP address NET-MAC Get MAC address NET-MASK Set/get subnet mask 13.3.4.1 ETH-PORT Functions Permission Transparency Set: ETH-PORT Administrator Public Get: ETH-PORT? End User Public Description Syntax Set: Set Ethernet port protocol #ETH-PORTSPportType,ETHPortCR Get: Get Ethernet port protocol #ETH-PORT?SPportTypeCR Response ~nn@ETH-PORTSPportType,ETHPortCR LF Parameters portType – string of 3 letters indicating the port type: TCP, UDP ETHPort – TCP / UDP port number: 0-65565 Response Triggers Notes If the port number you enter is already in use, an error is returned The port number must be within the following range: 0-(2^16-1) K-Config Example Set the Ethernet port protocol for TCP to port 12457: “#ETH-PORT TCP,12457”,0x0D

VS-42UHD - Protocol 3000

61 13.3.4.2 NET-DHCP Functions Permission Transparency Set: NET-DHCP Administrator Public Get: NET-DHCP? End User Public Description Syntax Set: Set DHCP mode #NET-DHCPSPmodeCR Get: Get DHCP mode #NET-DHCP?CR Response ~nn@NET-DHCPSPmodeCR LF Parameters mode – 0 (do not use DHCP. Use the IP address set by the factory or the NET-IP command), 1 (try to use DHCP. If unavailable, use the IP address set by the factory or the NET-IP command) Response Triggers Notes Connecting Ethernet to devices with DHCP may take more time in some networks To connect with a randomly assigned IP by DHCP, specify the device DNS name (if available) using the NAME command. You can also get an assigned IP by direct connection to USB or RS-232 protocol port if available Consult your network administrator for correct settings K-Config Example Enable DHCP mode, if available: “#NET-DHCP 1”,0x0D

VS-42UHD - Protocol 3000

13.3.4.3 NET-GATE Functions Permission Transparency Set: NET-GATE Administrator Public Get: NET-GATE? End User Public Description Syntax Set: Set gateway IP #NET-GATESPip_addressCR Get: Get gateway IP #NET-GATE?CR Response ~nn@NET-GATESPip_addressCR LF Parameters ip_address – gateway IP address, in the following format: xxx.xxx.xxx.xxx Response Triggers Notes A network gateway connects the device via another network, possibly over the Internet. Be careful of security problems. Consult your network administrator for correct settings. K-Config Example Set the gateway IP address to 192.168.0.1: “#NET-GATE 192.168.000.001”,0x0D 13.3.4.4 NET-IP Functions Permission Transparency Set: NET-IP Administrator Public Get: NET-IP? End User Public Description Syntax Set: Set IP address #NET-IPSPip_addressCR Get: Get IP address #NET-IP?CR Response ~nn@NET-IPSPip_addressCR LF Parameters ip_address – IP address, in the following format: xxx.xxx.xxx.xxx Response Triggers Notes Consult your network administrator for correct settings K-Config Example Set the IP address to 192.168.1.39: “#NET-IP 192.168.001.039”,0x0D

VS-42UHD - Protocol 3000

63 13.3.4.5 NET-MAC Functions Permission Transparency Set: - - - Get: NET-MAC? End User Public Description Syntax Set: - - Get: Get MAC address #NET-MAC?CR Response ~nn@NET-MACSPmac_addressCR LF Parameters mac_address – unique MAC address. Format: XX-XX-XX-XX-XX-XX where X is hex digit Response Triggers Notes K-Config Example “#NET-MAC?”,0x0D 13.3.4.6 NET-MASK Functions Permission Transparency Set: NET-MASK Administrator Public Get: NET-MASK? End User Public Description Syntax Set: Set subnet mask #NET-MASKSPnet_maskCR Get: Get subnet mask #NET-MASK?CR Response ~nn@NET-MASKSPnet_maskCR LF Parameters net_mask - format: xxx.xxx.xxx.xxx Response Triggers The subnet mask limits the Ethernet connection within the local network Consult your network administrator for correct settings Notes K-Config Example Set the subnet mask to 255.255.0.0: “#NET-MASK 255.255.000.000”,0x0D

VS-42UHD - Protocol 3000

13.3.5 EDID Handling Commands Additional EDID data functions can be performed via the VS-42UHD Web pages or a compatible EDID management application, such as Kramer EDID Designer (see www.kramerav.com/product/EDID%20Designer). Command Description CPEDID Copy EDID data from the output to the input EEPROM 13.3.5.1 CPEDID Functions Permission Transparency Set: CPEDID End User Public Get: - - - Description Syntax Set: Copy EDID data from the output to the input EEPROM #CPEDIDSPsrc_type,src_id,dst_type, dest_bitmapCR Get: - - Response ~nn@CPEDIDSPsrc_type,src_id,dst_type,dest_bitmapCR LF Parameters src_type – EDID source type (usually output): 0 (input), 1 (output), 2 (default EDID) src_id – for input source: 1 (HDMI In 1), 2 (HDMI In 2), 3 (HDMI In 3), 4 (HDMI In 4), for output source: 1 (HDMI Out 1), 2 (HDMI Out 2), for default EDID source: 0 (default EDID) dst_type – EDID destination type (usually input): 0 (input), 1 (output), 2 (default EDID) dest_bitmap – bitmap representing destination IDs. Format: XXXX…X, where X is hex digit. The binary form of every hex digit represents corresponding destinations. Setting ‘1’ indicates that EDID data is copied to this destination. Setting ‘0’ indicates that EDID data is not copied to this destination. Response Triggers Response is sent to the com port from which the Set was received (before execution) Notes Destination bitmap size depends on device properties (for 64 inputs it is a 64-bit word) Example: bitmap 0x0013 means inputs 1, 2 and 5 are loaded with the new EDID. In this device, if the destination type is input (0), the bitmap size is 3 bits, for example bitmap 0x5 means inputs 1 and 3 are loaded with the new EDID. K-Config Example Copy the EDID data from the HDMI Out output (EDID source) to the HDMI In 1 input: “#CPEDID 1,1,0,0x1”,0x0D Copy the EDID data from the default EDID source to HDMI In 1 and PC In inputs: “#CPEDID 2,0,0,0x5”,0x0D

Disconnect the unit from the power supply before opening and servicing

For the latest information on our products and a list of Kramer distributors, visit our Web site to find updates to this user manual. We welcome your questions, comments, and feedback. www.kramerAV.com [email protected] P/N: 2900-300609 Rev: 1

Other Matrix Switcher Manuals