G E M - X 2 5 5

CONTROL PANEL/COMMUNICATOR W1092B 9/02 © Napco 2002 Quick Start: 1. Refer to the wiring diagram, connect the keypad(s), siren, aux. power, aux. output, remote bus, earth ground, zone and telephone wiring. NOTE: See Installation Instructions (WI1093). 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 52). 4. Access the Easy Menu Driven (Dealer Program) Mode: Press EEEEEE A Press NO (g) Until “ACTIVATE PROGRAM Y/N” appears on the keypad display. Press YES (F) To Enter Dealer Program Mode. (see page 6 for programming guide). Master Security Code (on microshield) GEM-RP1CAe2 R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA SYSTEM ARMED 01/01/00 12:00 AM

NAPCO Security Systems, Inc.

333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com GEM-X255 Notes: ! For a GEM-X255 system comprising 96 zones or less, the system may be keypad programmed. A system larger than 96 zones must be downloaded with NAPCO PCD-Windows Version 4.1. This manual contains Easy Program Mode instructions, which allows the the first 96 zones to be completely programmed through Menu Driven Easy Program Mode. ! The GEM-X255 requires the use of version 7 firmware GEM-RP1CAe2 7 keypads: The keypad version can be identified by a compatibility sticker on keypad carton as well as a product version number of 07. The product version number appears as a 2 digit number which follows a 5 digit date code stamped on the the inside end flap of the carton (ex: XXXXX07DR). This number will also appear on the product on a triangular shaped sticker. The firmware version of the keypad can also be ascertained by entering the program mode—it will read [2307 Program Mode]. ! The GEM-X255 requires the use of version 7 firmware GEM-EZM-8 zone expansion modules. This version zone expansion modules can be identified by a compatibility sticker on the keypad carton as well as a product version number of 11. The product version number appears as a 2 digit number which follows a 5 digit date code stamped on the carton (ex: XXXXX11DR). This number will also appear on the on the the inside end flap of the carton as well as on the circuit board on a triangular shaped sticker. System features ! Chime 2 zone provides second distinct pulsating “Chime Zone” tone ! Set System Time and Date in User Program Mode ! System Trouble Audible Automatic Timeout ! Inhibit System Trouble Audible ! Easy Programming of PC Preset Auto download ID and Callback Numbers ! Support of GEM-PRINT module ! Cancel Reporting Code ! Wireless Trouble Reporting by Zone ! Pager (Telco 3) Reporting Delay ! Pager - Programmable Number of Reports of Same Signal ! Pager - Maximum Number of Consecutive Pages ! Specific Logging of Communication Failure Modes ! New Relay Event “Area Disarmed” (PCD- Windows programmable only) ! Programmable DST start date (PCD-Windows programmable only) CHANGES FROM PREVIOUS EDITION The following changes have been made to this manual (WI1092B) since the previous edition (WI1092A): Page 22, Address 4089 – Answer on Rings changed from “1-9” to “3-9”. Page 25, CS REPORTING CODES – Addresses added for “Telemetry Trouble” and “Telemetry Fail”. Page 25, CS REPORTING CODES, Address 0896 – Changed “RF Receiver Tamper” to “RF Tamper”. Pages 33-37, ZONE OPTIONS: Duplicate addresses corrected. Page 39, Address 2417 – “Ans. Machine P/U w/o Line Seizure” deleted. Page 40, Address 2421, Bit 1 – Changed “Don’t Clear Aux. Relay with Arm/Disarm” to “Don’t Clear Aux. Relay with Disarm” Page 40, Address: 2421, Bit 8 – Changed “Aux. Output Chirp on Keyfob Arming” to “Aux. Output Chirp on Keyfob Arm/ Disarm”

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 3 SYSTEM PROGRAMMING OPTIONS.............................4 Introduction ..................................................................4 Downloading from a Computer ....................................4 EASY MENU DRIVEN PROGRAM MODE.......................5 Dealer Program - Preliminary Information ...................5 Accessing Dealer Program Mode ................................5 Customizing a Default Program...................................5 GEM-RP1CAe2 KEYPAD............................................6 Number of Zones & Keypads per Area...................6 Local or Central Station Reporting System.............6 Central Station Receiver 1 Tel. Number.................7 Central Station Receiver 1 Account Number..........7 Central Station Receiver 1 Format .........................8 Enter User Codes ...................................................9 RF Transmitter Points.............................................11 Key Fob Transmitters .............................................12 Enter Zone Descriptions .........................................12 Enter Date...............................................................12 Enter Time .............................................................13 Enter Dealer Code..................................................13 Clear Dealer Program.............................................13 DIRECT ADDRESS PROGRAM MODE...........................14 Accessing Direct Address Program Mode ...................14 Direct Address Program Mode Keypad Commands....15 Programming Overview ...............................................15 Direct Address Programming Example...................16 PROGRAMMING OPTIONS & WORKSHEETS ..............19 System Delays (Addr 0000-0002, 2402, 2406 & 2414)20 System Delays (Addr 2407, 2408 & 4088)...................20 System Delays (Addr 2400, 2401, 2403-2405 & 4083)21 Keypad System Codes (Addr 0490, 0495 & 0500)......21 CS Receiver Opt. (Addr 0520, 0521, 0525, 0526, 0550, 0551, 0575 & 0576) .....................................................22 CS Receiver Tel. Numbers (Addr 0527-0546, 0552-0571, 0577-0596)...................................................................23 Download/Callback Options (Addr 4089, 0600-0619, 0625-0647, 1022 & 1023) ............................................23 CS Subscriber ID Numbers (Addr 0650-0857) ............24 CS Reporting Codes (Addr 0860-0869) ......................25 CS Reporting Codes (Addr 0870-0904) ......................26 CS Area & System Reporting Opt. (Addr 1024-1027).26 CS Zone Reporting Codes (Addr 0910-0904) .............27 CS User Reporting Codes (Addr 1030-1081)..............28 Global System Trbl. Reporting Opt. (Addr 1082-1116)29 Area System Trbl. Reporting Opt. (Addr 1120-1137) ..30 Zones 1-96 Options (Addr 1200-2376)........................32 System Options (Addr 2415-2419)..............................39 System Options (Addr 2420-2422 & 4084)..................40 Keypad Options (Addr 2425-2454)..............................43 User Area Options (Addr 2500-2595)..........................43 EZM Group Options (Addr 2600-2643) .......................45 Area Arming Options (Addr 2650-2657)......................46 Remote Access Logging (Addr 3184)..........................46 Area Output Control Options (Addr 2700-2739)..........46 RF Rcvrs. & Sup. Timers (Addr 3776 & 3760-3775) ...47 System Reset Features (Addr 4091-4093)..................48 USER PROGRAM MODE ................................................49 Preliminary Information................................................49 Accessing User Program Mode...................................49 User Codes..................................................................49 Zone Descriptions........................................................50 KEYPAD CONFIGURATION MODE................................51 Keypad Installation ......................................................51 Configuring the Keypads .............................................51 KEYPAD PROGRAMMING MODES ...............................53 PROGRAMMING OPTIONS INDEX ................................58 GEM-X255 WIRING DIAGRAM .......................................63 LIMITED WARRANTY .....................................................64 TABLE OF CONTENTS Refer to accompanying GEM-X255 Installation Instructions (WI1093) for installation information. NOTE: THESE INSTRUCTIONS ARE INTENDED AND WRITTEN FOR PROFESSIONAL INSTALLATION PERSONNEL HAVING SUITABLE TRAINING, EXPERIENCE AND INSTALLATION EQUIPMENT. IT IS RECOMMENDED THAT AFTER PROGRAMMING, THE ERROR CHECK UTILITY OF THE PCD3000 DOWNLOADER BE USED TO VERIFY THAT THE CONTROL PANEL PROGRAM CONTAINS NO ERRORS OR CONFLICTS WHICH MAY INHIBIT ITS INTENDED OPERATION.

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 4 SYSTEM PROGRAMMING OPTIONS INTRODUCTION The GEM-X255 control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown are for a GEM-RP1CAe2 (Version 7), ! Downloading From a Computer. This is the preferred method. The panel may be downloaded from (or uploaded to) an IBM PC-compatible computer, with a 386 (or higher) microprocessor, either locally or remotely. NAPCO's PCD-Windows software, Version 4.1 or later features context-sensitive help screens as well as an error-checking utility that prevents programming of incompatible or conflicting data to ensure proper panel operation. ! Easy Menu Driven Program (Dealer Program) Mode - Keypad Programming. The Easy Menu Driven Program Mode allows the programming of up to a 96 zone, 2 area system. A system larger than 96 zones must be programmed via the PCD-Windows program. Keypad programmable features include number of zones in area 1, number of zones in area 2, fire zone numbers (both 4-wire and 2-wire), central station reporting, entry/exit zone numbers, interior zone numbers, number of keypads in area 1, number of keypads in area 2, central station telephone number, central station account number, auto download id number & PC preset callback telephone number, central station receiver format, user codes, RF transmitter points, RF key fob transmitters,zone descriptions,date and time. For new panels, a custom default program may be created at the keypad. A menu-driven utility prompts the installer to configure the system. Further detailed customization is done in the Direct Address Program Mode. ! Direct Address (Dealer Program) Program Mode - Keypad Programming. The Direct Address Program Mode is an extension of the Dealer Program Mode wherein data is entered at the keypad by location. This mode is accessed from the Easy Menu Driven Program Mode by pressing the C button at any time. ! User Program Mode - Keypad programming. The User Program Mode is intended for authorized users and is limited to keypad programming of User Codes, Zone Descriptions, Time and Date. DOWNLOADING FROM A COMPUTER The control-panel program may be downloaded from the computer by either of the following methods. Local Downloading (Note: This procedure should be used after installation, after peripheral devices are connected.) For a direct high-speed data transfer to the control panel from a desktop computer, connect the download jack (J1) on the panel to the LOCAL jack (J3) on the Napco PCI2000/3000 computer interface using the supplied 6-conductor cable. (Refer to PCI2000/3000 Installation Instructions WI443 for wiring diagram and procedures.) Similarly, a high-speed local download may be made in the field using a notebook or laptop computer. Connect J1 on the control panel to a Napco PCI-MINI computer interface using the 6-conductor cable supplied. (Refer to PCI-MINI Installation Instructions WI767.) Remote Downloading (Also see PCI2000/3000 Installation Instructions WI443.) Function Mode. During this procedure, voice contact will be lost, therefore both the installer and the computer operator should be familiar with the operation. When a steady high-pitched tone is heard at the site phone, access the “ACTIVATE DOWNLOAD” Function (see Keypad Programming Modes), then press the J button or the YES (E) button; the site phone will go dead. Hang up the phone and wait for a call from the central station confirming a successful download. Callback Method. An installed, unattended panel may be programmed or reprogrammed remotely using the Callback- Method Download feature of PCD-Windows software. Remote downloading requires a modem compatible with the PCI2000/3000. Upon answering the call from the computer, the panel will verify the Download Security Code and, if confirmed, will establish a connection. If a Callback Number is programmed into the panel, the panel will automatically disconnect and call the computer at this number before establishing a connection. The panel can support two Callback Numbers to allow downloads from two different offices.

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 5 EASY MENU DRIVEN PROGRAM MODE DEALER PROGRAM - PRELIMINARY INFORMATION ! Only Keypad #1 may be used for both dealer and user programming, however this keypad may be located in any area. ! The Master Security Code is printed on the panel’s microprocessor can. Use this code to enter the Dealer Program Mode to program a custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized access to the panel. If you forget your Dealer Security Code, use the Master Security Code to enter programming. ! After entering codes or data, press the save Jbutton. Data will not be stored into memory unless it is pressed. ! If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound. Silence the sounder by pressing the G button to continue, or by pressing the C button to exit. ! A panel that has been COLD STARTED (Address Location 4093) performs identically to a new panel. ! When programming more than 2 areas, Direct Address Programming Mode must be used to complete the program. ACCESSING DEALER PROGRAM MODE CUSTOMIZING A DEFAULT PROGRAM For any new panel, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for: This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been loaded, you may alter it as necessary in the Direct Address Program Mode. NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any means, the number of areas, number of zones, fire zones, entry/exit zones and interior zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the C button to enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the J button and start over. Accessing Dealer Program Mode 1. Press EEEEEE A 2. Press g Until “ACTIVATE PROGRAM Y/N” appears on the keypad display. 3. Press F To Enter Dealer Program Mode. 4. Press CC To Exit Dealer Program Mode when finished. Master Security Code (on microshield) R GEM-P3200 CONTROL COMMUNCIATOR MASTER SECURITY CODE # - # - # - # - # - # GEM- R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X AI #ZN=08 #KP=1 ���������������� A2 #ZN=00 #KP=0 ! Number of Zones in Area 1 ! Number of Zones in Area 2 ! Fire Zones ! 2-Wire Fire Zones ! Local System or Central Station Reporting ! Exit/Entry Zones ! Interior Zones ! Number of Keypads in Area 1 ! Number of Keypads in Area 2 ! CS Receiver 1 Telephone Number ! Auto Download ID Number & P ! C Preset Callback Telephone Number ! CS Receiver 1 Account Number ! CS Receiver 1 Format ! User Codes ! RF Transmitter Points ! Key Fob Transmitters ! Zone Descriptions * ! Date * ! Time * ! Dealer Code * NOTE: GEM-RP1CAe2 Keypad Only

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 6 GEM-RP1CAe2 Keypad: Zones per Area, Fire Zones, 2-Wire Fire Zones & CS Reporting A. GEM-RP1CAe2 Keypad To create your customized default program using a GEM-RP1CAe2 keypad, enter the following parameters. In each of the following steps, press the A button to set cursor, the NEXT (E) button to go forwards, the PRIOR (F) button to go backwards, the Jbutton to save and the C button twice to exit at any time. Total Number of Zones in Area 1 & Area 2 (Appears for New Panel Only) Directly enter the total number of zones to be programmed for Area 1 and Area 2, respectively. Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros. Use number buttons 1 through 9. NOTE: Press the 0 button for a zero. The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the next group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press Jto save. Press NEXT (E) button to proceed. Note: The GEM-X255 is limited to a maximum of 96 zones and 15 keypads. All 96 zones and 15 keypads may be programmed in the EZ Program Mode. For larger systems, refer to the PCD-Windows downloader. Fire Zones (Appears for New Panel Only) Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless). Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros, and press Jto save, and then repeat for any additional zone(s). Press NEXT (E) button to proceed. NOTE: If you are programming a 2 Area system, enter the zone number of zones required for Areas 1 & 2. All fire zones are common to areas 1 and 2. The Direct Address Program Mode can then be used to customize them as needed. See Zone Options. 2-Wire Fire Zones (Appears for New Panel Only) Enter the zone number of any Fire Zones (from previous question) which are to be used with 2-wire smoke detectors. The only valid entries are 01 through 08. Directly enter each zone number, including leading zeros. Press Jto save, and then repeat for any additional zone(s). NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones. Press NEXT (E) button to proceed. NOTE: JP7 must be set to “2-WF” position for 2-wire fire zones 7 and 8 (refer to Installation Instructions). Local System or C.S. Reporting System (Appears for New Panel Only) Press YES (E) button for all zones to report; press NO (F) button for no zones to report (LOCAL SYSTEM). R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X AI #ZN=08 #KP=1 ����������������� A2 #ZN=00 #KP=0 (Direct Entry) #OF ZNS IN AREA1 ENTER # ZONES 08 (Direct Entry) #OF ZNS IN AREA2 ENTER # ZONES 00 (Direct Entry) F I R E Z O N E S ENTER ZONE # 00 (Direct Entry) 2 - W I R E F I R E Z N S ENTER ZONE # 00 (Press YES or NO) REPORT ALL ZONES TO CENTRAL? Y/N

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 7 Exit/Entry Zones (Appears for New Panel Only) Directly enter the zone numbers which are to be used as Exit/Entry zones. Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros. Use number buttons 1 through 9. NOTE: Press the 0 button for a zero. Press Jto save and then repeat for any additional zone(s). Press NEXT (E) button to proceed. NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exit delay of 60 seconds. Chime will automatically be programmed for all E/E zones. If you are programming a 2 Area system, enter all of the zones required for Areas 1 & 2. Interior Zones (Appears for New Panel Only) Directly enter the zone numbers which are to be used as Interior Zones. Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros. Use number buttons 1 through 9. NOTE: Press the 0 button for a zero. Press Jto save and then repeat for any additional zone(s). Press NEXT (E) button to proceed. NOTE: All Interior zones will also be automatically programmed as “Exit/Entry Follower” zones. If you are programming a 2 Area system, enter all the zones required for Areas 1 & 2. Number of Keypads in Area 1 Directly enter the total number of Keypads to be installed in Area 1. Valid entries are from 01 to 15. Directly enter the number of keypads, including leading zeros. Use number buttons 1 through 9. NOTE: Press the 0 button for a zero. Press Jto save. Press NEXT (E) to proceed. Number of Keypads in Area 2 Directly enter the total number of Keypads to be installed in Area 2. Valid entries are from 01 to 15. Central Station Receiver 1 Telephone Number Using number buttons, enter telephone number of up to 16 digits including prefix letters, if necessary, for receiver 1. Use number buttons 1 through 9 for digits 1–9; press the G 0 button for a zero and G 1 through G 5 for letters B–F, respectively. NOTE: Pre-Dial Delay = “D”; Dial-Tone Detection = “E”. Pressing the 0 button will produce a blank space (•). Press Jto save. Press NEXT (E) to proceed. NOTE: Central Station Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address Programming. See CS Receiver Options. (Direct Entry) EXIT/ENTRY ZONES ENTER ZONE # 00 (Direct Entry) INTERIOR ZONES ENTER ZONE # 00 (Direct Entry) # AREA 1 KEYPADS E N T E R # K P S 0 1 (Direct Entry) # AREA 2 KEYPADS E N T E R # K P S 0 0 (Direct Entry) CENTRAL PHONE # _ _ _ _ _ _ _ _ _ _ _ _ _ GEM-RP1CAe2 Keypad: Exit/Entry Zones, Interior Zones, Keypads per Area, CS Tel. No. & CS Acct. No. Easy Programming of Auto download ID #'s and PC Preset Callback Numbers For unattended PC Preset downloading, it is now possible to set the Auto download ID #’s and PC Preset Callback from the Keypad Easy Program Mode. • At the field for CENTRAL PHONE #, program an "F" followed by the Auto Download ID # (2 digits) and then the Callback Telco # (up to 13 digits). • Press [ON/OFF] to save. • Exit Program Mode ([RESET] [RESET]). • Enter Master Code • Press [FUNCTION] • Go to Function "ACTIVATE DOWNLOAD Y/N" and press YES (INTERIOR). • The panel will automatically call the PC Preset computer and download the program on the specified Auto Download line # of PC Preset. Example: Program an Auto download ID # of 07 and a PC Preset Callback # of 1-516-842-9400 • Go to Central Phone # input screen and press: [*] [5] [0] [7] [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] [ON/OFF] CENTRAL PHONE # F 0 7 1 5 1 6 8 4 2 9 4 0 0

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 8 Central Station Receiver 1 Account Number Enter an account number of up to four digits. Use number buttons 1 through 9 for digits 1–9. NOTE: Press the 0 button for a zero and press the G 0 buttons for a blank space (•).G 1 through G 5 for letters B–F, respectively. Press Jto save . Press NEXT (E) button to proceed. NOTE: Central Station Receiver 2 and 3 Account Numbers can only be entered in Direct Address Programming. See CS Reporting Options. Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9. NOTE: Press the 0 button for a zero. and press the G 0 buttons for a blank space (•). Press G 1 through G 4 for letters B–E, respectively. Press Jto save. Press NEXT (E) button to proceed. DATA ENTRY CS RECEIVER 1 FORMAT blank(•) Ademco Slow, Silent Knight Slow 1 Sescoa, Vertex, DCI, Franklin Fast 2 Radionics Fast 3 Silent Knight Fast 4 Radionics, DCI, Franklin Slow 5 Universal High Speed 8 Radionics BFSK DATA ENTRY CS RECEIVER 1 FORMAT 9 FBI 4/3/1 0 Radionics Modem 2 B SIA C Ademco Point ID D Ademco Express E Pager NOTE: Modem IIe is available only in Direct Address Programming. Central Station Receiver 2 and 3 Formats can only be entered in Direct Address Programming. See CS Receiver Options. (Direct Entry) SEE WI FOR INFO RCVR FORMAT (0) GEM-RP1CAe2 Keypad: CS Format (Direct Entry) CENTRAL STATION ACCOUNT #(____ )

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 9 GEM-RP1CAe2 Keypad: User Codes Enter User Codes (Press the (A) button to set cursor.) Enter up to 195 User Codes with User Options, Authority Level and Access Control Options (if necessary) for each code. Refer to the tables below and on the next page for available data entries for User Options, Authority Level and Access Control Options. Note: The 195 Users must be assigned to areas in “Enable User Code by Area” (Address 2500-2595) in Direct Address Programming. By default, only User 1 is enabled in Area 1 and Area 2. User 2 - 8 are enabled in Area 1 and user 9 - 16 are enabled in Area 2. ! Press the (A) button to set the cursor to the User Code. Use the number buttons 1 through 9 to enter a code of up to 6 digits. Enter up to 6 digits (4 digits is recommended) in the first six boxes from left to right for each user code. Valid entries are: 0-9. Note: Press the 0 button for a zero. No blank spaces in between; leave blank (•) any trailing boxes. If an “Ambush Code” (Address 0495) is entered, do not program the first two digits of ANY User Code as the same digits entered for the “Ambush Code”. ! If the programmed code is less than 6 digits, press the A button to set the cursor to the OPTION/LEVEL. Refer to the tables below for the available User Option and User Level data entries. Enter the user options data in the left digit. Enter the level data (with arming options, if any, added) in the right digit. Note: For entries greater than 9, press the G1 buttons through the G5 buttons for B through F, respectively. ! For Keypad Access Control, press the A button once again to program applicable keypads. Refer to the tables below, use the number buttons to enter the data for Keypad 1–4 in the right digit; and the data for Keypad 5–8 data in the left digit. (Press the 0 buttons for blank.) User# User Code Option Access /Level Control ENTER USER CODE 001 123___ -F3- __ USER OPTIONS USER CODE (UP TO 6 DIGITS) USER OPTION USER LEVEL ACCESS CONTROL KEYPADS DATA ENTRIES AUTHORITY LEVEL CODE TYPE blank (•) NONE ARM/DISARM 1 LEVEL 1 ARM/DISARM 2 LEVEL 2 ARM/DISARM 3 LEVEL 3 ARM/DISARM 4 NONE ARM ONLY 5 LEVEL 1 ARM ONLY 6 LEVEL 2 ARM ONLY 7 LEVEL 3 ARM ONLY 8 NONE SERVICE 9 LEVEL 1 SERVICE 0 LEVEL 2 SERVICE B LEVEL 3 SERVICE Note: “Y” indicates option is enabled. USER OPTIONS DATA ENTRIES BLOCKED VIEW USER PROGRAM BYPASS OVERVIEW blank (•) DISABLED 1 Y 2 Y 3 Y Y 4 Y 5 Y Y 6 Y Y 7 Y Y Y 8 Y 9 Y Y 0 Y Y B Y Y Y C Y Y D Y Y Y E Y Y Y F Y Y Y Y Note: “Y” indicates option is enabled. ACCESS CONTROL KEYPADS DATA ENTRIES K.P. 1 K.P. 2 K.P. 3 K.P. 4 blank (•) NONE 1 Y 2 Y 3 Y Y 4 Y 5 Y Y 6 Y Y 7 Y Y Y 8 Y 9 Y Y 0 Y Y B Y Y Y C Y Y D Y Y Y E Y Y Y F Y Y Y Y Example: Enter a code of “123456” as “123456” (from left to right). Note: “Y” indicates option is enabled. ACCESS CONTROL KEYPADS DATA ENTRIES K.P. 5 K.P. 6 K.P. 7 K.P. 8 blank (•) NONE 1 Y 2 Y 3 Y Y 4 Y 5 Y Y 6 Y Y 7 Y Y Y 8 Y 9 Y Y 0 Y Y B Y Y Y C Y Y D Y Y Y E Y Y Y F Y Y Y Y

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 10 ! Press Jto save each code. To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program a new User Code as previously described. Press NEXT (E) button to proceed. GEM-RP1CAe2 Keypad: User Codes Example: Program a code of “2222” for user 02, with User Option of “User Program”, User “Level 3” and Access Control Option “Keypad No. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for access control option. CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press Jto save. Similarly, to cancel a code, blank out each number of the code and press Jto save to save. USER AUTHORITY LEVEL KEYPAD DISPLAY FUNCTION MENU FUNCTION LEVEL* DISPLAY ZN FAULTS 1 DISPLAY ZN BYPASSED 1 DISPLAY ZN DIRECTORY 1 ACTIVATE BELL TEST 1 DISPLAY PHONE #’S 1 DISPLAY SYS TRBL 1 DISPLAY FIRE ALARM 1 DISPLAY FIRE TRBL 1 DISPLAY OP/CL 3 ACTIVATE OVERVIEW 3** ACTIVATE CHIME 1 ACTIVATE WATCH 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND *** ACTIVATE LOCATE *** EZM ZONE FIND *** ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG 3 DISPLAY TOTAL LOG 3 DISPLAY FIRE LOG 3 DISPLAY OP/CL LOG 3 DISPLAY SYSTEM LOG 3 AUTOARM IN 1-4HRS 2 DISPLAY AUTOARM SCHD 3 ACTIVATE PROGRAM 3** ACTIVATE DOWNLOAD 3 DISPLY RF XMITTER STAT 1 RELAY CONTROL 1 NOTES: * Minimum Level required to access function ** Level-3 Code with appropriate user option *** Requires Dealer Code Related User Options: “Ambush Code” (Address 0495), “Panel Access Code” (Address 0490), “Dealer Security Code” (Address 0500) & “Enable User Code by Area” (Address 2500-2595). USER OPTIONS OPTIONS EXPLANATION Disabled User Code not active in this area. Blocked View Allows User Code to block another code from being viewed by another user. An unblocked code cannot view a blocked code, but a blocked code can view all codes. The master user code and the dealer program code can view all codes. User Program User Program Option is enabled for Keypad 1 only, wherever it is connected (any area). If enabled, Level 3 must also be enabled. Bypass Allows User Code to bypass zones. Overview This option, along with Level 3 Authorization, enables selection of OVERVIEW mode at a keypad. This Mode provides a system status display of all areas at a glance. Arm Only Prevents User Code from disarming this area. Service A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, a “SERVICE ON” appears on the GEM-RP2ASe2 keypad (a “S” on the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid User Code, including a Service Code. If the area is armed with OTHER than a Service Code, it CANNOT be disarmed with a Service Code. This is typically used to allow tradesmen access to premises under control of the owner. Access This is normally used to activate a door striker while an area is disarmed. A code with the access option will not function as an arm/disarm code. When the code is entered, the keypad will display “ENTER NOW” and the Brown Wire on the keypad will become Active Low (Ground Potential) for 7 seconds.

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 11 RF Transmitter Points (Press the (A) button to set cursor.) (For wireless systems only. Also see Quick Method, which follows) For each transmitter (key fob transmitters also), enter the zone number (01–96) to which the transmitter will be mapped, the 6-digit RF ID #:1-digit checksum number printed on the transmitter and box, the point number (1–4); enter “9” for unsupervised (all points). NOTE: When programming the ID Code number, “A” = G 0; “B” = G 1; “C” = G 2; “D” = G 3; “E” = G 4; “F” = G 5. Press Jto save. Press NEXT (E) button to proceed. Quick Method. If a receiver is already installed in the panel, Napco transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled only if the signal strength is 3 or greater. 1. Enter the zone number to which the transmitter point will be mapped. 2. Press the B button to enter the Enroll Mode. The red and green LEDs on the keypad will flash and the window will display as shown at left. 3. Open the loop of the point that is to be programmed (GEM-TRANS2 or GEM-TRANS4 only). 4. Install the transmitter battery. The keypad will beep to indicate that the point has been successfully enrolled. Multi-point transmitters can be mapped to successive zones simultaneously (Example 1) or to selected zones point by point (Example 2). Example 1. A 4-point transmitter has the RF ID number 410078:1. Map the first three points to Zones 11–13, respectively. 1. Enter the Enroll mode as described in step 2 above. 2. Enter Zone “11”. 3. Open the loops of points 1, 2 and 3. 4. Install the transmitter battery. The keypad will beep 3 times to indicate that three points have been programmed. ! Transmitter 410078:1, point 1 will be mapped to Zone 11. ! Transmitter 410078:1, point 2 will be mapped to Zone 12. ! Transmitter 410078:1, point 3 will be mapped to Zone 13. The keypad will now display Zone 13, the last zone enrolled. Example 2. A 2-point transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9. 1. Enter the Enroll mode as described above. 2. Enter Zone “06”. 3. Open point-1 loop. 4. Install the battery. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1, point 1 will be mapped to Zone 6.) 5. Enter Zone “09”. 6. Close point-1 loop and open point-2 loop. 7. Remove the transmitter battery, then re-install it. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1, point 2 is mapped to Zone 9.) Zone # Xmitter Check Point Mapped to ID Sum # ZN# XMIT#+CS P ZN01-000000: 0- 0 ZN# XMIT#+CS P ZN01-000000: 0- 0 ZN# XMIT#+CS P ZN01-ENROLL:A-- KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm system, each reporting to a central station, a pager or having a description on the keypad that describes the person holding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the key fob button being depressed. See the next page on Key fob Zone Assignment. GEM-RP1CAe2 Keypad: RF Transmitter Points

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 12 Key Fob Transmitters (Press the (A) button to set cursor.) Keyfobs can be programmed as “Arm/Disarm” devices.(refer to WI752). For each Key Fob Transmitter, enter: ! the Key Fob Transmitter number (01–16). ! area number to which transmitter is assigned (1-8); enter 0 to disable keyfob. ! the 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including leading “0”s, if any). ! 1-digit checksum number printed on the transmitter (enter all numbers and/or letters, including leading “0”s, if any). ! Aux-1 Option (see key fob aux 1 & aux 2 options). ! Aux-2 Option (see key fob aux 1 & aux 2 options). Note: If the Key Fob is converted for Two Button “Emergency Use” (by cutting an internal jumper), both top or bottom buttons must be depressed to activate an alarm. In this case, Aux-1 and Aux-2 cannot be programmed. Press Jto save. Press NEXT (E) button to proceed. Key Fob Zone Assignment (refer to display as shown on the previous page: press the (F) button to go backwards.) Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point 3; A2 = point 4. Up to 96 key fobs (using 1 button) or 48 key fobs (using 2 buttons) or 28 key fobs (using all 4 buttons) or any combination up to a maximum of 96 controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone number with description/location. To assign a key fob to a zone: program the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: If assigning a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is converted to a “panic only” device. Enter Zone and Interior Descriptions Press the 1 and 2 buttons to place the cursor; press the 3 and 6 buttons to select the character. For each zone, enter a description of up to two lines. Press Jto save each description. To proceed to the next description, place the cursor under the Zone Number (e.g. “01”) and change the Zone Number using the 3 and 6 buttons. Program a new description as above. NOTE: Zone Descriptions can only be entered through the GEM-/RP1CAe2 Keypad or by using the Napco Quickloader Software. Press NEXT (E) button to proceed. Enter Date (Press the (A) button to set cursor.) Enter the current date in the format MM/DD/YY, where MM = the month (01–12); DD=the day (01–31); and YY=the year. Press Jto save. Press NEXT (E) button to proceed. KF Area Xmitter Check Aux # ID Sum 1&2 KF A XMIT#+ CS OP 0 1 - 0 0 0 0 0 0 0 : 0 0 0 DATA ENTRY AUX 1/AUX 2 OPTIONS 0 None 1 Relay Group 1 Toggle 2 Relay Group 2 Toggle 3 Relay Group 3 Toggle 4 Relay Group 4 Toggle 5 Relay Group 5 Toggle 6 Relay Group 6 Toggle 7 Relay Group 7 Toggle 8 Relay Group 8 Toggle 9 Panic A Auxiliary B Instant C Aux. Output Toggle D Access on Aux. Output NOTE: Key fobs 1-16 report openings and closings as Users 180-195. GEM-RP1CAe2 Keypad: Keyfob Transmitters, Zone Descriptions & Date (Direct Entry) 001-_____________ ________________ (Direct Entry) E N T E R D A T E ( 0 1/ 0 1/ 9 9 )

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 13 Enter Time (Press the (A) button to set cursor.) Enter the current time in the format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59). Select Am or Pm by pressing any number button, then press Jonce again to save. Dealer Code Directly enter the Dealer Code, including leading zeros. Use the 1 through 9 buttons. NOTE: Press the 0 button for a zero. Press Jto save. Re-enter the Dealer Code to verify the previous code. Press Jto save. Press NEXT (E) button to proceed. NOTE: The Dealer Code can be two or more digits (up to 6 digits). CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the C button to enter the Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (Cold Start); (c) press Jand then (d) press the C button to exit the Dealer Program Mode. A “SYSTEM TROUBLE/E09-00 SERVICE” will occur. Press the C button to silence the keypad. (Direct Entry) E N T E R T I M E ( 1 2 : 0 5 A ) (Direct Entry) DEALER CODE •••••• (Direct Entry) DEALER CODE RE-ENTER EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the C button to enter the Direct Address Program Mode for further programming or press the C button once again to end all programming and resume normal keypad operation. Clear Dealer Program (Erases Dealer Program) This erases the dealer program. Use this feature to start a customized default program. Program Data and System Status Memory is erased where Scheduled Data and Zone Descriptions are maintained. Access address 4091, then press the Jbutton. Data entry is not allowed. NOTE: Enter Easy Menu Driven Program Mode to program system again. GEM-RP1CAe2 Keypad 4091 •• Cold Start (Erases Entire Program) This erases the entire program including Program Data, Zone Description Data, System Status Data, Schedule Data and Foreign Language configuration(similar to a new panel). Access address 4093, then press the Jbutton. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software. GEM-RP1CAe2 Keypad 4093 •• GEM-RP1CAe2 Keypad: Time, Dealer Code & Exit Dealer Program Mode

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 14 Accessing Direct Address Program Mode DIRECT ADDRESS PROGRAM MODE DISPLAY & COMMANDS 0000 3C 0 0 0 0 3 C ( S E C O N D S ) 1 2 = DATA ENTRY LOCATION (Left and Right 2 = ADDRESS 1 1. Press EEEEEE A 2. Press g Until “ACTIVATE PROGRAM Y/N” appears on the keypad display. 3. Press F To Enter Dealer Program Mode Master Security Code (printed on microprocessor can) or Dealer Security Code (Address 0500) DIRECT ADDRESS PROGRAM MODE R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X AI #ZN=08 #KP=1 ��������������� A2 #ZN=00 #KP=0 This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad Programming Worksheets that follow. Refer to these worksheets to identify the 4-digit location (address) of the feature to be programmed. An illustrative example is provided on the next page. KEYPAD PROGRAMMING OVERVIEW Direct Address Programming allows you to go directly to the address locations and change the data entries to customize your control panel options. Whereas the Easy Menu Program Mode is a simple quick start guide with limited options, the Direct Address Program Mode is more flexible allowing you to change all the options. It consists of multiple address locations (up to 4093) with two data entry locations each (left and right) as shown in the adjacent diagram. ACCESSING DIRECT ADDRESS PROGRAM MODE DATA ENTRY LOCATIONS LEFT DIGIT RIGHT DIGIT 3 C ADDRESS LOCATIONS 0000 0000 TO 4093 HEXADECIMAL DATA: BLANK (•) = No Options 1 to 9 = Entries 1 to 9 0 = Entry of 10 B to F = Entries 11 to 15

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 15 The displays shown on the previous page will appear after a brief delay. ! Use the the A button to toggle the cursor between the 4-digit address field and the data entry locations. ! Enter the address directly using the number buttons. ! The contents of the address will be read automatically, along with the feature name and programming information. The cursor will advance to the data field. Enter the required data directly using the number buttons. ! Press Jto save the contents of each address. PROGRAMMING OVERVIEW The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the installer modify his custom default program or to make minor field alterations to an existing panel program. It is recommended that the panel be uploaded to NAPCO's Quickloader software following any keypad programming and that the PCD-Window's error-check feature be utilized to reduce the possibility of programming omissions or conflicts. Note: Most of the addresses shown comprise two data entry locations, left and right digits. Program the left digits on the left data-display segment, and the right digit on the right segment. For those addresses having only one programmable nibble, program the right segment only; the left segment should display a blank (•). Keep the Keypad Programming Worksheets on file for future reference. General Programming Steps ! 1. Contact the central station to ascertain receiver format, data format, event codes, subscriber numbers and telephone number(s). ! 2. Select the desired features by circling " the respective “address” boxes. Refer to the Programming Options and Worksheets for guidance in selecting the “data” (1,2,4,8) to be entered into those boxes. ! 3. Program the data entered in the boxes on the worksheets into the respective addresses. The display will show the entry numerically, but will display “0” for the number 10, and letters “B”, “C”, “D”, “E”, and “F” for the numbers 11 through 15, respectively. To program a 10, press G 0. To program 11 through 15, press G 1 through G 5, respectively. NOTE: See the Direct Address Programming Example on the following page. EXIT DIRECT ADDRESS PROGRAM MODE: When done, press C to exit and resume normal keypad operation. Direct Address Program Mode: Program Overview & General Programming Steps DATA ENTRY SELECTIONS (BINARY VALUE CIRCLED) " ENTRY TOTAL PRESS N KEYPAD DISPLAY 8 4 2 1 blank 0 • 8 4 2 ! 1 1 1 8 4 " 1 2 2 2 8 4 " ! 3 3 3 8 # 2 1 4 4 4 8 # 2 ! 5 5 5 8 # " 1 6 6 6 8 # " ! 7 7 7 $ 4 2 1 8 8 8 $ 4 2 ! 9 9 9 $ 4 " 1 10 G 0 0 $ 4 " ! 11 G 1 B $ # 2 1 12 G 2 C $ # 2 ! 13 G 3 D $ # " 1 14 G 4 E $ # " ! 15 G 5 F Table 1. Determining data entry for a location (each “nibble”). Numbers in parentheses indicate data for selected zones or features. (See Programming Worksheets that follow.)

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 16 Direct Address Programming Example Example: Program Zones 6, 7 and 8 as Exit/Entry Follower Zones. DETERMINE THE DATA ENTRIES ! 1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5 through 8 are located at address 1218, left digit. Circle " the data values for Zones 5–8. ! 2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, “14” (E) is entered as press G4. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as a blank (•). PROGRAM THE DATA ENTRIES ! 1. Enter the panel's Dealer Security Code (Address 0500), then press the A button. ! 2. Answer NO (F) to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES (E). NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using the the B button. ! 3. Press the C button to enter the Address Program Mode. Address "0000" will display. ! 4. Press 1 2 1 8 to access Address 1218. The data for both digits will display and the cursor will advance to the data field. ! 5. Press G 4 to enter an “E” in the left digit and press 0 to enter a blank (•) in the right digit. ! 6. Press Jto save. Address 1218 is now programmed with “E•”. ZONE OPTION EXIT/ENTRY FOLLOWER ZONES LEFT DATA VALUES SUM = 14 (CIRCLE ") ZN08 ZN07 ZN06 ZN05 $ # " 1 ADDRESS 1218 L ADDR R E 1218 blank (•) ZONES RIGHT DATA VALUES SUM = 0 (CIRCLE ") ZN04 ZN03 ZN02 ZN01 8 4 2 1 ENTER DATA " Direct Address Program Mode: Programming Example

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 17 PROGRAMMING OPTIONS & WORKSHEETS R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X AI #ZN=08 #KP=1 ��������������� A2 #ZN=00 #KP=0 1. Press EEEEEE A 2. Press g Until “ACTIVATE PROGRAM Y/N” appears on LCD screen. 3. Press F To Enter Dealer Program Mode 4. Press C To Exit Easy Menu Driven Program Mode & Enter Direct Address Program Mode Dealer Code (Address 0500) Determining data entry for a location (each “nibble”). Numbers in parentheses indicate data for selected zones or features. (See Programming Worksheets that follow.) DEFAULTS: The defaults shown on the following pages are automatically set after exiting the Easy Menu Driven ENTER DATA " ADDRESS LOC. LEFT RIGHT Program Option PROGRAMMING STEPS: 1. Lookup desired Programming Option by Address Location (highlighted in black). 2. Select the programming option data entry from the tables shown, by direct entry or by adding binary values. 3. Enter the selected data entry in the boxes shown. 4. For more information on a programming option refer to the Glossary at the end of this manual. ENTRY TOTAL PRESS N KEYPAD DISPLAYS blank 0 • 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 G 0 0 11 G 1 B 12 G 2 C 13 G 3 D 14 G 4 E 15 G 5 F Direct Address Program Mode: Programming Options & Worksheets

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 18 R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X AI #ZN=08 #KP=1 ��������������� A2 #ZN=00 #KP=0 THIS PAGE INTENTIONALLY LEFT BLANK

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 19 SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 2402, 2406, 2414 & 3902) ADDRESS 0000 LEFT RIGHT EXIT DELAY (sec.) [Default = 3C] ADDRESS 0001 LEFT RIGHT ENTRY DELAY 1 (sec.) [Default = 1E] ADDRESS 0002 LEFT RIGHT ENTRY DELAY 2 (sec.) [Default = 1 E] PROGRAMMING TIMEOUTS: Either use the tables provide or calculate your own timeout using the steps indicated. WARNING: Timers have uncertainty of +/-1sec, so a "time" of 1 second may actually timeout IMMEDIATELY. ADDRESS 2406 LEFT RIGHT ABORT DELAY (sec.) [Default = blank (•) blank (•)] DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) F 1 E 2 D 3 C 5 0 7 8 F F DELAY/ TIMEOUT 0 sec. 15 sec. 30 sec. 45 sec. 60 sec. 90 sec. 120 sec. 255 sec. ! 1. Select delay/timeout (0-255 sec.) from the table shown. ! 2. Enter in corresponding address locations above (left and right digits). ! 3. For a desired delay/timeout not listed do the following: A. Choose a desired delay/timeout, ex: 20 sec. B. Divide it by 16 EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options “Entry/Exit 1, Entry/Exit 2, Exit/Entry Follower”. For UL Installations, the maximum exit delay is 60 seconds and the maximum entry delay is 45 seconds. 1 Quotient Left Digit 16 20 16 4 Remainder Right Digit SYSTEM DELAYS & TIMEOUTS (ADDRESS 2407, 2408 & 4088) ADDRESS 2407 LEFT RIGHT CHIME TIMEOUT (¼sec.) [Default = blank (•) 2] DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 blank (•) 7 blank (•) 8 F F TIMEOUT 0 ¼sec. = 0 sec. 2 ¼sec. = ½ sec. 3 ¼sec. = ¾ sec. 4 ¼sec. = 1 sec. 5 ¼sec. = 1.25 sec. 6 ¼sec. = 1.5 sec. 7 ¼sec. = 1.75 sec. 8 ¼sec. = 2 sec. 255 ¼sec. = 63.25 sec. CHIME TIMEOUT OPTIONS [Default = blank (•) blank (•)] ADDRESS 2408 LEFT RIGHT AC Fail Report Delay (min.) DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 blank (•) 7 F F DELAY 0 min. 10 min. 20 min. 30 min. 40 min. 50 min. 60 min. 70 min. 2550 min. = 42 Hr., 30 min. AC FAIL REPORT DELAY OPTIONS ! 1. Select delay/timeout from the table shown. ! 2. Enter in corresponding address locations above (left and right digits). ! 3. For a desired delay/timeout not listed do the following: A. Choose a desired delay/timeout , ex: 20. Note: For Sensor Watch only divide it by 10, ex: 20/10 = 2 B. Divide it by 16 1 Quotient Left Digit 16 20 16 4 Remainder Right Digit ADDRESS 2402 LEFT RIGHT Aux. Output Access Control Timeout (sec.) [Default = blank (•) blank (•)] ADDRESS 4088 LEFT RIGHT Sensor Watch Delay (Hr.) DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 blank (•) 7 F F DELAY 0 Hr. 1 Hr. 2 Hr. 3 Hr. 4 Hr. 5 Hr. 6 Hr. 7 Hr. 255 Hr. SENSOR WATCH OPTIONS [Default = blank (•) blank (•)] ADDRESS 2414 LEFT RIGHT Telephone Line Test Delay (sec.) System Delays/Timeouts [Default = blank (•) blank (•)] ADDRESS 3902 LEFT RIGHT CS Telco 3 Report Delay (sec.)

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 20 [Default = blank (•) blank (•) from address 0490-0492] SYSTEM DELAYS & TIMEOUTS (ADDRESS 2400, 2401, 2403-2405, 4082 & 4083) DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 1 blank (•) F F DELAY/ TIMEOUT 0 min. 1 min. 2 min. 3 min. 4 min. 5 min. 6 min. 16 min. 255 min. [Default = blank (•) blank (•)] ADDRESS 2400 LEFT RIGHT Reset Output Timeout (min.) [Default = blank (•) blank (•) ] ADDRESS 2401 LEFT RIGHT Aux. Output Timeout (min.) [Default = 1 blank (•)] ADDRESS 2403 LEFT RIGHT Burg. Alarm Output Timeout (min.) ! 1. Select delay/timeout (0-255 min.) from the table shown. ! 2. Enter in corresponding address locations above (left and right digits). ! 3. For a desired delay/timeout not listed do the following: A. Choose a desired delay/timeout, ex: 20 min. B. Divide it by 16 OUTPUT TIMEOUTS: If a timeout of “0 min.” is selected, then the output will remain active (ON) until the system is reset or disarmed. For UL Residential Installations, the minimum timeout is 4 minutes. For UL Commercial Installations, the minimum timeout is 15 minutes. [Default = blank (•) 1] ADDRESS 2404 LEFT RIGHT Pulse Alarm Output Timeout (min.) [Default = blank (•) blank (•) ] ADDRESS 2405 LEFT RIGHT Fire Output Timeout (min.) [Default = blank (•) blank (•)] ADDRESS 4083 LEFT RIGHT Auto Disarm Rearm Delay (min.) KEYPAD SYSTEM CODES (ADDRESS 0490, 0495 & 0500) DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming. ! 1. Enter in both left and right digits of address locations. ! 2. Valid entries are: 0-9. Note: If left blank, the Master Security Code must then be used to enter programming. AMBUSH CODE: Enter a 2-digit code used just prior to disarming and will activate an Ambush Condition, causing a SILENT report to be sent to the central station. ! 1. Enter in both left and right digits of address locations. ! 2. Valid entries are: 0-9. Note: Also, “Enable Keypad Ambush” (Address 2440-2446), “Report on Ambush Alarm” (Address 1125, 1127, 1135 & 1137) and “Ambush Code” (Address 0900) must all be enabled. Panel Access Code ADDRESS 0490-0492 0490 0491 0492 L R L R L R PANEL ACCESS CODE: Enter up to 6 digits to activate a door strike while the area is disarmed. ! 1. Enter in both left and right digits of address locations. ! 2. Valid entries are: 0-9. Note: Also, “Access Control on Aux. Output” (Address 2418) and “Aux. Output Access Control Timeout” (Address 2402) must both be enabled. ADDRESS 0495 LEFT RIGHT Ambush Code [Default = blank (•) blank (•)] [Default = blank (•) blank (•) from address 0500-0502] Dealer Security Code ADDRESS 0500-0502 0500 0501 0502 L R L R L R System Delays/Timeouts & Keypad Codes [Default = blank (•) blank (•)] ADDRESS 4082 LEFT RIGHT Report Cancel Window (sec.) 1 Quotient Left Digit 16 20 16 4 Remainder Right Digit

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 21 Default for CS Receiver 1 Format depends on Easy Menu Question “RCVR FORMAT”. [Default = •(blank) •(blank)] for CS Receivers 2 and 3 Formats. CS RECEIVER FORMAT OPTIONS (ADDRESS 0520, 0521, 0525, 0526, 0550, 0551, 0575 & 0576) ADDRESS 0525 LEFT RIGHT CS Receiver 1 Format CS RECEIVER FORMATS: Up to 3 CS Formats may be programmed. ! 1. Select the desired CS Receiver Format from the table shown. ! 2. Enter in the corresponding left and right digit address locations for each CS Receiver. NOTE: Dark shaded data value box shows option not available. ADDRESS 0550 LEFT RIGHT CS Receiver 2 Format ADDRESS 0575 LEFT RIGHT CS Receiver 3 Format [Default = blank (•) blank (•)] [Default = blank (•) blank (•)] [Default = blank (•) blank (•)] ADDRESS 0526 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 1 OPTIONS 1400Hz Handshake/Kissoff * 2300Hz Handshake/Kissoff * Enable Zone Number on Pulse Alarm Single Digit Only LEFT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 1 OPTIONS Sum Check 3/1 with Extended Restores RESERVED RESERVED CS RECEIVER OPTIONS: Select options for any of the three CS Receivers. ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. NOTE: * If both are selected, 1400Hz has priority over 2300Hz. ADDRESS 0551 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 2 OPTIONS 1400Hz Handshake/Kissoff * 2300Hz Handshake/Kissoff * Enable Zone Number on Pulse Alarm Single Digit Only LEFT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 2 OPTIONS Sum Check 3/1 with Extended Restores RESERVED RESERVED ADDRESS 0576 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 3 OPTIONS 1400Hz Handshake/Kissoff * 2300Hz Handshake/Kissoff * Enable Zone Number on Pulse Alarm Single Digit Only LEFT DATA VALUES (CIRCLE ") 1 2 4 8 CS RECEIVER 3 OPTIONS Sum Check 3/1 with Extended Restores RESERVED RESERVED CS RECEIVER FORMATS Ademco Slow, Silent Knight Slow Sescoa, Vertex, DCI, Franklin Fast Radionics Fast Silent Knight Fast Radionics, DCI, Franklin Slow Universal High Speed Radionics BFSK FBI 4/3/1 Radionics Modem 2 SIA Ademco Point ID Ademco Express Pager Radionics Modem IIe DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 8 blank (•) 9 blank (•) 0 blank (•) B blank (•) C blank (•) D blank (•) E 1 blank (•) LEADING DIGITS FOR PAGER FORMAT: In Pager Format reporting, the message typically begins with “00”. However, for some pager services, this will cause the Pager's Voice Mail feature to activate. This option allows you to program these digits to any number desired. Typical Pager report is “003 022 1234”, where 3 is the Event, 22 is the zone, and 1234 is the Subscriber ID number. For example, if the Leading Digits are programmed as “98”, the Pager report will now appear as “983 022 1234”. ! 1. Enter in 1st and 2nd Leading Digits in right digit only (left digit is not used) as shown. ! 2. Valid entries are: 0-9. [Default = blank (•) blank (•)] Leading Digits for Pager Format (1st Digit) ADDRESS 0520 LEFT RIGHT blank (•) [Default = blank (•) blank (•)] Leading Digits for Pager Format (2nd Digit) ADDRESS 0521 LEFT RIGHT blank (•) CS Receiver Format Options

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 22 CS Receiver 1 Telephone Number (Digits 1-20) ADDRESS 0527-0546 (RIGHT DIGITS 1-20) 0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545 0546 R R R R R R R R R R R R R R R R R R R R CS Receiver 2 Telephone Number (Digits 1-20) ADDRESS 0552-0571 (RIGHT DIGITS 1-20) 0552 0553 0554 0555 0556 0557 0558 0559 0560 0561 0562 0563 0564 0565 0566 0567 0568 0569 0570 0571 R R R R R R R R R R R R R R R R R R R R CS Receiver 3 Telephone Number (Digits 1-20) ADDRESS 0577-0596 (RIGHT DIGITS 1-20) 0577 0578 0579 0580 0581 0582 0583 0584 0585 0586 0587 0588 0589 0590 0591 0592 0593 0594 0595 0596 R R R R R R R R R R R R R R R R R R R R CS RECEIVER TELEPHONE NUMBERS: Enter telephone numbers for any of the three CS Receivers (Telco 1, 2 & 3). ! 1. Enter in right digit only (left digit is not used). ! 2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•). ! 3. Valid entries are: 1-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location Default for CS Receiver 1 Telephone Number depends on Easy Menu Question “CENTRAL PHONE #”. [Default = blank (•)] across digits 1-20 for CS Receiver Telephone Numbers 2 and 3. CS RECEIVER TELEPHONE NUMBERS (ADDRESS 0527-0546, 0552-0571, 0577-0596) DOWNLOAD/CALLBACK OPTIONS (ADDRESS 4089, 0600-0619, 0625-0647, 1022 & 1023) NUMBER OF RINGS BEFORE PICKUP: Enter the number of rings before automatic pickup by the control panel when downloading from a computer (see Glossary at the back for more information). ! 1. Enter in right digit only (left digit is not used). ! 2. Valid entries are: 3-9, 0 = 10, B = 11, C = 12, D = 13, E = 14, F = 15 NOTE: Default is 15 Rings. Dark shaded data shows option not available. CALLBACK TELEPHONE NUMBERS: Enter telephone numbers to be used when downloading from a computer. ! 1. Enter in right digit only (left digit is not used). ! 2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•). ! 3. Valid entries are: 0-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location [Default = blank (•) for all digits 1-20] ADDRESS 0600-0619 (RIGHT DIGITS 1-20) 0600 0601 0602 0603 0604 0605 0606 0607 0608 0609 0610 0611 0612 0613 0614 0615 0616 0617 0618 0619 R R R R R R R R R R R R R R R R R R R R Callback Telephone Number 1 (Digits 1-20) ADDRESS 4089 LEFT RIGHT blank (•) No. Rings Before Pickup [Default = blank (•) F] [Default = blank (•) for all digits 1-20] ADDRESS 0625-0644 (RIGHT DIGITS 1-20) 0625 0626 0627 0628 0629 0630 0631 0632 0633 0634 0635 0636 0637 0638 0639 0640 0641 0642 0643 0644 R R R R R R R R R R R R R R R R R R R R Callback Telephone Number 2 (Digits 1-20) [Default = blank (•) blank (•)] Download Security Code ADDRESS 0645-0647 0645 0646 0647 L R L R L R DOWNLOAD SECURITY CODE: Enter up to 6 digits to be used for remote access when downloading from a computer. ! 1. Enter in both left and right digits of address locations. ! 2. Valid entries are: 0-9. Note: Download Security Code must match the code entered in the PCD3000 Software. ADDRESS 1022 LEFT RIGHT blank (•) Callback Telephone No. Select [Default = blank (•) blank (•)] CALLBACK TELEPHONE NO. SELECT: Enter either “1” for Callback Telephone Number 1 or “2” for Callback Telephone Number 2. ! 1. Enter in right digit only (left digit is not used). ! 2. Valid entries are: 1 or 2. CS Receiver Telephone Numbers & Download/Callback Options ADDRESS 1023 LEFT RIGHT Auto Download ID No. [Default = blank (•) blank (•)] Valid entries - 01-99

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 23 CS SUBSCRIBER ID NUMBERS (ADDRESS 0650-0787) CS Subscriber ID Numbers (TELCO 1 & 2) AREA 1 ADDRESS 0650-0653 (RIGHT DIGITS 1-4) 0650 0651 0652 0653 R R R R CS TELCO 1 SUBSCRIBER OPENING/CLOSING ID NUMBERS AREA 2 ADDRESS 0654-0657 (RIGHT DIGITS 1-4) 0654 0655 0656 0657 R R R R AREA 3 ADDRESS 0658-0661 (RIGHT DIGITS 1-4) 0658 0659 0660 0661 R R R R AREA 4 ADDRESS 0662-0665 (RIGHT DIGITS 1-4) 0662 0663 0664 0665 R R R R AREA 5 ADDRESS 0666-0669 (RIGHT DIGITS 1-4) 0666 0667 0668 0669 R R R R AREA 6 ADDRESS 0670-0673 (RIGHT DIGITS 1-4) 0670 0671 0672 0673 R R R R AREA 7 ADDRESS 0674-0677 (RIGHT DIGITS 1-4) 0674 0675 0676 0677 R R R R AREA 8 ADDRESS 0678-0681 (RIGHT DIGITS 1-4) 0678 0679 0680 0681 R R R R AREA 1 ADDRESS 0682-0685 (RIGHT DIGITS 1-4) 0682 0683 0684 0685 R R R R CS TELCO 1 SUBSCRIBER EVENT ID NUMBERS AREA 2 ADDRESS 0686-0689 (RIGHT DIGITS 1-4) 0686 0687 0688 0689 R R R R AREA 3 ADDRESS 0690-0693 (RIGHT DIGITS 1-4) 0690 0691 0692 0693 R R R R AREA 4 ADDRESS 0694-0697 (RIGHT DIGITS 1-4) 0694 0695 0696 0697 R R R R AREA 5 ADDRESS 0698-0701 (RIGHT DIGITS 1-4) 0698 0699 0700 0701 R R R R AREA 6 ADDRESS 0702-0705 (RIGHT DIGITS 1-4) 0702 0703 0704 0705 R R R R AREA 7 ADDRESS 0706-0709 (RIGHT DIGITS 1-4) 0706 0707 0708 0709 R R R R AREA 8 ADDRESS 0710-0713 (RIGHT DIGITS 1-4) 0710 0711 0712 0713 R R R R SYSTEM ADDRESS 0714-0717 (RIGHT DIGITS 1-4) 0714 0715 0716 0717 R R R R AREA 1 ADDRESS 0720-0723 (RIGHT DIGITS 1-4) 0720 0721 0722 0723 R R R R CS TELCO 2 SUBSCRIBER OPENING/CLOSING ID NUMBERS (BACKUP REPORTING AREA 2 ADDRESS 0724-0727 (RIGHT DIGITS 1-4) 0724 0725 0726 0727 R R R R AREA 3 ADDRESS 0728-0731 (RIGHT DIGITS 1-4) 0728 0729 0730 0731 R R R R AREA 4 ADDRESS 0732-0735 (RIGHT DIGITS 1-4) 0732 0733 0734 0735 R R R R AREA 5 ADDRESS 0736-0739 (RIGHT DIGITS 1-4) 0736 0737 0738 0739 R R R R AREA 6 ADDRESS 0740-0743 (RIGHT DIGITS 1-4) 0740 0741 0742 0743 R R R R AREA 7 ADDRESS 0744-0747 (RIGHT DIGITS 1-4) 0744 0745 0746 0747 R R R R AREA 8 ADDRESS 0748-0751 (RIGHT DIGITS 1-4) 0748 0749 0750 0751 R R R R AREA 1 ADDRESS 0752-0755 (RIGHT DIGITS 1-4) 0752 0753 0754 0755 R R R R CS TELCO 2 SUBSCRIBER EVENT ID NUMBERS (BACKUP REPORTING) AREA 2 ADDRESS 0756-0759 (RIGHT DIGITS 1-4) 0756 0757 0758 0759 R R R R AREA 3 ADDRESS 0760-0763 (RIGHT DIGITS 1-4) 0760 0761 0762 0763 R R R R AREA 4 ADDRESS 0764-0767 (RIGHT DIGITS 1-4) 0764 0765 0766 0767 R R R R AREA 5 ADDRESS 0768-0771 (RIGHT DIGITS 1-4) 0768 0769 0770 0771 R R R R AREA 6 ADDRESS 0772-0775 (RIGHT DIGITS 1-4) 0772 0773 0774 0775 R R R R AREA 7 ADDRESS 0776-0779 (RIGHT DIGITS 1-4) 0776 0777 0778 0779 R R R R AREA 8 ADDRESS 0780-0783 (RIGHT DIGITS 1-4) 0780 0781 0782 0783 R R R R SYSTEM ADDRESS 0784-0787 (RIGHT DIGITS 1-4) 0784 0785 0786 0787 R R R R

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 24 CS REPORTING CODES (ADDRESS 0859-0869) ADDRESS 0864-0869 LEFT ADDR RIGHT blank (•) 0864 blank (•) 0865 blank (•) 0866 blank (•) 0867 0868 0869 OPENING/CLOSING REPORTING CODES Closing Conditional Closing Opening Opening after Alarm Fail to Close Fail to Open ADDRESS 0860-0862 LEFT ADDR RIGHT blank (•) 0859 blank (•) 0860 blank (•) 0861 blank (•) 0862 ALARM/TROUBLE REPORTING CODES Cancel Alarm Restore Trouble Trouble Restore [Default = blank (•) blank (•) from address 0859-0869] CS REPORTING CODES: ! 1. Enter in corresponding address location (left and right digits). ! 2. Valid entries are: 1-9, 0 and B-F. NOTE: Dark shaded data value box shows option not available. Default for CS Telco 1 Subscriber Event ID Number (Area 1) depends on Easy Menu Question “ACCOUNT #”. [Default = blank (•) blank (•) blank (•) blank (•)] for all other ID Numbers. CS TELCO SUBSCRIBER ID NUMBERS: Enter the Subscriber Opening/Closing and Event ID Numbers for any of the 3 CS Receivers. ! 1. Enter in corresponding right digit address location (left digit is not used). ! 2. Enter 3 or 4 digits (depending on the CS receiver format) for each subscriber number from left to right. NOTE: Leave trailing boxes blank (•). ! 3. Valid entries are: 0-9, 0 and B-F. CS SUBSCRIBER ID NUMBERS (ADDRESS 0790-0857) AREA 1 ADDRESS 0790-0793 (RIGHT DIGITS 1-4) 0790 0791 0792 0793 R R R R CS TELCO 3 SUBSCRIBER OPENING/CLOSING ID NUMBERS AREA 2 ADDRESS 0794-0797 (RIGHT DIGITS 1-4) 0794 0795 0796 0797 R R R R AREA 3 ADDRESS 0798-0801 (RIGHT DIGITS 1-4) 0798 0799 0800 0801 R R R R AREA 4 ADDRESS 0802-0805 (RIGHT DIGITS 1-4) 0802 0803 0804 0805 R R R R AREA 5 ADDRESS 0806-0809 (RIGHT DIGITS 1-4) 0806 0807 0808 0809 R R R R AREA 6 ADDRESS 0810-0813 (RIGHT DIGITS 1-4) 0810 0811 0812 0813 R R R R AREA 7 ADDRESS 0814-0817 (RIGHT DIGITS 1-4) 0814 0815 0816 0817 R R R R AREA 8 ADDRESS 0818-0821 (RIGHT DIGITS 1-4) 0818 0819 0820 0821 R R R R AREA 1 ADDRESS 0822-0825 (RIGHT DIGITS 1-4) 0822 0823 0824 0825 R R R R CS TELCO 3 SUBSCRIBER EVENT ID NUMBERS AREA 2 ADDRESS 0826-0829 (RIGHT DIGITS 1-4) 0826 0827 0828 0829 R R R R AREA 3 ADDRESS 0830-0833 (RIGHT DIGITS 1-4) 0830 0831 0832 0833 R R R R AREA 4 ADDRESS 0834-0837 (RIGHT DIGITS 1-4) 0834 0835 0836 0837 R R R R AREA 5 ADDRESS 0838-0841 (RIGHT DIGITS 1-4) 0838 0839 0840 0841 R R R R AREA 6 ADDRESS 0842-0845 (RIGHT DIGITS 1-4) 0842 0843 0844 0845 R R R R AREA 7 ADDRESS 0846-08449 (RIGHT DIGITS 1-4) 0846 0847 0848 0849 R R R R AREA 8 ADDRESS 0850-0853 (RIGHT DIGITS 1-4) 0850 0851 0852 0853 R R R R SYSTEM ADDRESS 0854-0857 (RIGHT DIGITS 1-4) 0854 0855 0856 0857 R R R R CS Subscriber ID Numbers (TELCO 3) & CS Reporting Codes

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 25 CS REPORTING CODES: ! 1. Enter in corresponding address location (left and right digits). ! 2. Valid entries are: 1-9, 0 and B-F. NOTE: Dark shaded data value box shows option not available. ADDRESS 0870-0880 LEFT ADDR RIGHT 0870 0871 0872 0873 0874 0875 0876 0877 blank (•) 0878 blank (•) blank (•) 0879 blank (•) 0880 0882 0883 SYSTEM REPORTING CODES Test Timer Alarm Supervisory Bus Failure Memory Failure Panel Low Battery Panel AC Failure EZM Tamper Sensor Watch RESERVED RESERVED Telco Line Failure Telemetry Trouble Telemetry Failure CS REPORTING CODES (ADDRESS 0870-0904) [Default = blank (•) blank (•) from address 0870-0904] ADDRESS 0890-0897 LEFT ADDR RIGHT 0890 0891 blank (•) 0892 blank (•) 0893 0894 0895 0896 0897 SYSTEM REPORTING CODES Digital Dialer Test GuardTour Fail RESERVED Service Message Program Change RF Receiver Trouble RF Tamper RF Trouble ADDRESS 0900-0904 LEFT ADDR RIGHT 0900 0901 0902 0903 0904 KEYPAD REPORTING CODES Ambush Panic Fire Auxiliary Tamper CAUTION: For all 2-Digit Reporting Formats (see CS Receiver Format Options), use the following: Example: The 2-digit reporting code as shown is “21”. ADDRESS LOC. LEFT RIGHT 1 2 Reporting Code 2nd Digit of Reporting Code 1st Digit of Reporting Code CS AREA & SYSTEM REPORTING OPTIONS (ADDRESS 1024-1027) * NOTE: If neither TouchTone Dialing nor TouchTone w/Rotary Backup is selected, then system defaults automatically to Rotary Dialing. Leave blank (•) to select Rotary Dialing. CS AREA & SYSTEM REPORTING OPTIONS: ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. [Default = blank (•) blank (•)] ADDRESS 1027 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 CS SYSTEM REPORT OPTIONS Cancel Next Test Timer on any Report Disable Wait for Silence Disable Wait for Handshake Handshake for Local Telemetry RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 CS SYSTEM REPORT OPTIONS Backup Report on Telco 2 TouchTone Dialing Only * TouchTone Dialing w/Rotary Backup * Transmit “402” Opening/Closing Code CS Reporting Codes & CS Reporting Options [Default = blank (•) blank (•)] DISABLE OPENING REPORTS ADDRESS 1024 LEFT DIGIT RIGHT DIGIT LEFT DATA VALUES (CIRCLE ") 1 2 4 8 AREA Area 1 Area 2 Area 3 Area 4 LEFT DATA VALUES (CIRCLE ") 1 2 4 8 AREA Area 5 Area 6 Area 7 Area 8 [Default = blank (•) blank (•)] DISABLE CLOSING REPORTS ADDRESS 1025 LEFT DIGIT RIGHT DIGIT LEFT DATA VALUES (CIRCLE ") 1 2 4 8 AREA Area 1 Area 2 Area 3 Area 4 LEFT DATA VALUES (CIRCLE ") 1 2 4 8 AREA Area 5 Area 6 Area 7 Area 8

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 26 ADDRESS 0910-0917 ZONES REPORT CODE (CONTROL PANEL) ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 0910 0911 0912 0913 0914 0915 0916 0917 L R L R L R L R L R L R L R L R ADDRESS 0918-0921 ZONES REPORT CODE (GROUP 1) ZONE 9 ZONE 10 ZONE 11 ZONE 12 0918 0919 0920 0921 L R L R L R L R ADDRESS 0922-0925 ZONES REPORT CODE (GROUP 2) ZONE 13 ZONE 14 ZONE 15 ZONE 16 0922 0923 0924 0925 L R L R L R L R ADDRESS 0934-0937 ZONES REPORT CODE (GROUP 5) ZONE 25 ZONE 26 ZONE 27 ZONE 28 0934 0935 0936 0937 L R L R L R L R ADDRESS 0938-0941 ZONES REPORT CODE (GROUP 6) ZONE 29 ZONE 30 ZONE 31 ZONE 32 0938 0939 0940 0941 L R L R L R L R ADDRESS 0926-0929 ZONES REPORT CODE (GROUP 3) ZONE 17 ZONE 18 ZONE 19 ZONE 20 0926 0927 0928 0929 L R L R L R L R ADDRESS 0930-0933 ZONES REPORT CODE (GROUP 4) ZONE 21 ZONE 22 ZONE 23 ZONE 24 0930 0931 0932 0933 L R L R L R L R Default for Group Zone Report Codes depends on Easy Menu Question “RCVR. 7 Gas Alarm 8 Heat Alarm 0 Auxiliary Alarm B 24 Hour Auxiliary DATA ENTRIES LEFT 1 2 3 4 MODEM CODE Fire * Panic Burglary Hold up ZONE REPORT CODE OPTIONS DATA ENTRIES LEFT RIGHT NOTE: Zones 1-8 are included in the control panel and Zones 9-48 are EZM Zones. See Address 2600-2621 to enable “EZM Zone Groups”. PULSE EVENT CODE will be the first digit of the 2 digit reporting code. the second digit will be the second digit of the reporting zone. For example, for zone 9 (address 0918), if the right digit is “3", then the reporting code is “39”. For example, for zone 15 (address 0924), if the right digit is “4", then the reporting code is “45”. MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point ID. ! 1. Select the desired Modem Code for each zone from the table shown. CS ZONE REPORTING CODES (ADDRESS 0910-1005) ADDRESS 0950-0953 ZONES REPORT CODE (GROUP 9) ZONE 41 ZONE 42 ZONE 43 ZONE 44 0950 0951 0952 0953 L R L R L R L R ADDRESS 0954-0957 ZONES REPORT CODE (GROUP 10) ZONE 45 ZONE 46 ZONE 47 ZONE 48 0954 0955 0956 0957 L R L R L R L R ADDRESS 0942-0945 ZONES REPORT CODE (GROUP 7) ZONE 33 ZONE 34 ZONE 35 ZONE 36 0942 0943 0944 0945 L R L R L R L R ADDRESS 0946-0949 ZONES REPORT CODE (GROUP 8) ZONE 37 ZONE 38 ZONE 39 ZONE 40 0946 0947 0948 0949 L R L R L R L R CS Zone Reporting Codes ADDRESS 0966-0969 ZONES REPORT CODE (GROUP 13) ZONE 57 ZONE 58 ZONE 59 ZONE 60 0966 0967 0968 0969 L R L R L R L R ADDRESS 0970-0973 ZONES REPORT CODE (GROUP 14) ZONE 61 ZONE 62 ZONE 63 ZONE 64 0970 0971 0972 0973 L R L R L R L R ADDRESS 0958-0961 ZONES REPORT CODE (GROUP 11) ZONE 49 ZONE 50 ZONE 51 ZONE 52 0958 0959 0960 0961 L R L R L R L R ADDRESS 0962-0965 ZONES REPORT CODE (GROUP 12) ZONE 53 ZONE 54 ZONE 55 ZONE 56 0962 0963 0964 0965 L R L R L R L R ADDRESS 0982-0985 ZONES REPORT CODE (GROUP 17) ZONE 73 ZONE 74 ZONE 75 ZONE 76 0982 0983 0984 0985 L R L R L R L R ADDRESS 0986-0989 ZONES REPORT CODE (GROUP 18) ZONE 77 ZONE 78 ZONE 79 ZONE 80 0986 0987 0988 0989 L R L R L R L R ADDRESS 0974-0977 ZONES REPORT CODE (GROUP 15) ZONE 65 ZONE 66 ZONE 67 ZONE 68 0974 0975 0976 0977 L R L R L R L R ADDRESS 0978-0981 ZONES REPORT CODE (GROUP 16) ZONE 69 ZONE 70 ZONE 71 ZONE 72 0978 0979 0980 0981 L R L R L R L R ADDRESS 0998-1001 ZONES REPORT CODE (GROUP 21) ZONE 89 ZONE 90 ZONE 91 ZONE 92 0998 0999 1000 1001 L R L R L R L R ADDRESS 1002-1005 ZONES REPORT CODE (GROUP 22) ZONE 93 ZONE 94 ZONE 95 ZONE 96 1002 1003 1004 1005 L R L R L R L R ADDRESS 0990-0993 ZONES REPORT CODE (GROUP 19) ZONE 81 ZONE 82 ZONE 83 ZONE 84 0990 0991 0992 0993 L R L R L R L R ADDRESS 0994-0997 ZONES REPORT CODE (GROUP 20) ZONE 85 ZONE 86 ZONE 87 ZONE 88 0994 0995 0996 0997 L R L R L R L R

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 27 CS USER REPORTING CODES (ADDRESS 1030-1055) User Opening Telco 1 ADDRESS 1042 LEFT RIGHT blank (•) RIGHT DATA VALUES User 00 User 99 User 98 User 97 8 4 2 1 User 197 = Auto Arming/Disarming User 198 = Quickloader Arming/Disarming User 199 = Easy Arming (Opening not applicable) User 200 = Keyswitch Arming NOTE: These opening events will report as the user number shown. Also, Keyfobs 1-16 (see Easy Menu Program Driven Mode) will report as Users 180-195, respectively. User Opening Telco 1 LEFT DATA VALUES User 16 User 15 User 14 User 13 8 4 2 1 ADDRESS 1031 LEFT RIGHT RIGHT DATA VALUES User 12 User 11 User 10 User 9 8 4 2 1 LEFT DATA VALUES User 8 User 7 User 6 User 5 8 4 2 1 ADDRESS 1030 LEFT RIGHT RIGHT DATA VALUES User 4 User 3 User 2 User 1 8 4 2 1 User Opening Telco 1 LEFT DATA VALUES User 32 User 31 User 30 User 29 8 4 2 1 ADDRESS 1033 LEFT RIGHT RIGHT DATA VALUES User 28 User 27 User 26 User 25 8 4 2 1 LEFT DATA VALUES User 24 User 23 User 22 User 21 8 4 2 1 ADDRESS 1032 LEFT RIGHT RIGHT DATA VALUES User 20 User 19 User 18 User 17 8 4 2 1 User Opening Telco 1 LEFT DATA VALUES User 48 User 47 User 46 User 45 8 4 2 1 ADDRESS 1035 LEFT RIGHT RIGHT DATA VALUES User 44 User 43 User 42 User 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1034 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Opening Telco 1 LEFT DATA VALUES User 64 User 63 User 62 User 61 8 4 2 1 ADDRESS 1037 LEFT RIGHT RIGHT DATA VALUES User 60 User 59 User 58 User 57 8 4 2 1 LEFT DATA VALUES User 56 User 55 User 54 User 53 8 4 2 1 ADDRESS 1036 LEFT RIGHT RIGHT DATA VALUES User 52 User 51 User 50 User 49 8 4 2 1 User Opening Telco 1 LEFT DATA VALUES User 80 User 79 User 78 User 77 8 4 2 1 ADDRESS 1039 LEFT RIGHT RIGHT DATA VALUES User 76 User 75 User 74 User 73 8 4 2 1 LEFT DATA VALUES User 72 User 71 User 70 User 69 8 4 2 1 ADDRESS 1038 LEFT RIGHT RIGHT DATA VALUES User 68 User 67 User 66 User 65 8 4 2 1 User Opening Telco 1 LEFT DATA VALUES User 96 User 95 User 94 User 93 8 4 2 1 ADDRESS 1041 LEFT RIGHT RIGHT DATA VALUES User 92 User 91 User 90 User 89 8 4 2 1 LEFT DATA VALUES User 88 User 87 User 86 User 85 8 4 2 1 ADDRESS 1040 LEFT RIGHT RIGHT DATA VALUES User 84 User 83 User 82 User 81 8 4 2 1 User Closing Telco 1 ADDRESS 1055 LEFT RIGHT blank (•) RIGHT DATA VALUES User 00 User 99 User 98 User 97 8 4 2 1 User 197 = Auto Arming/Disarming User 198 = Quickloader Arming/Disarming User 199 = Easy Arming (Opening not applicable) User 200 = Keyswitch Arming NOTE: These opening events will report as the user number shown. Also, Keyfobs 1-16 (see Easy Menu Program Driven Mode) will report as Users 180-195, respectively. User Closing Telco 1 LEFT DATA VALUES User 16 User 15 User 14 User 13 8 4 2 1 ADDRESS 1044 LEFT RIGHT RIGHT DATA VALUES User 12 User 11 User 10 User 9 8 4 2 1 LEFT DATA VALUES User 8 User 7 User 6 User 5 8 4 2 1 ADDRESS 1043 LEFT RIGHT RIGHT DATA VALUES User 4 User 3 User 2 User 1 8 4 2 1 User Closing Telco 1 LEFT DATA VALUES User 32 User 31 User 30 User 29 8 4 2 1 ADDRESS 1046 LEFT RIGHT RIGHT DATA VALUES User 28 User 27 User 26 User 25 8 4 2 1 LEFT DATA VALUES User 24 User 23 User 22 User 21 8 4 2 1 ADDRESS 1045 LEFT RIGHT RIGHT DATA VALUES User 20 User 19 User 18 User 17 8 4 2 1 User Closing Telco 1 LEFT DATA VALUES User 48 User 47 User 46 User 45 8 4 2 1 ADDRESS 1048 LEFT RIGHT RIGHT DATA VALUES User 44 User 43 User 42 User 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1047 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Closing Telco 1 LEFT DATA VALUES User 64 User 63 User 62 User 61 8 4 2 1 ADDRESS 1050 LEFT RIGHT RIGHT DATA VALUES User 60 User 59 User 58 User 57 8 4 2 1 LEFT DATA VALUES User 56 User 55 User 54 User 53 8 4 2 1 ADDRESS 1049 LEFT RIGHT RIGHT DATA VALUES User 52 User 51 User 50 User 49 8 4 2 1 User Closing Telco 1 LEFT DATA VALUES User 80 User 79 User 78 User 77 8 4 2 1 ADDRESS 1052 LEFT RIGHT RIGHT DATA VALUES User 76 User 75 User 74 User 73 8 4 2 1 LEFT DATA VALUES User 72 User 71 User 70 User 69 8 4 2 1 ADDRESS 1051 LEFT RIGHT RIGHT DATA VALUES User 68 User 67 User 66 User 65 8 4 2 1 User Closing Telco 1 LEFT DATA VALUES User 96 User 95 User 94 User 93 8 4 2 1 ADDRESS 1054 LEFT RIGHT RIGHT DATA VALUES User 92 User 91 User 90 User 89 8 4 2 1 LEFT DATA VALUES User 88 User 87 User 86 User 85 8 4 2 1 ADDRESS 1053 LEFT RIGHT RIGHT DATA VALUES User 84 User 83 User 82 User 81 8 4 2 1 CS User Reporting Codes

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 28 CS USER REPORTING CODES (ADDRESS 1056-1081) User Opening Telco 3 ADDRESS 1068 LEFT RIGHT blank (•) RIGHT DATA VALUES User 100 User 99 User 98 User 97 8 4 2 1 User 197 = Auto Arming/Disarming User 198 = Quickloader Arming/Disarming User 199 = Easy Arming (Opening not applicable) User 200 = Keyswitch Arming NOTE: These opening events will report as the user number shown. Also, Keyfobs 1-16 (see Easy Menu Program Driven Mode) will report as Users 180-195, respectively. User Opening Telco 3 LEFT DATA VALUES User 16 User 15 User 14 User 13 8 4 2 1 ADDRESS 1057 LEFT RIGHT RIGHT DATA VALUES User 12 User 11 User 10 User 9 8 4 2 1 LEFT DATA VALUES User 8 User 7 User 6 User 5 8 4 2 1 ADDRESS 1056 LEFT RIGHT RIGHT DATA VALUES User 4 User 3 User 2 User 1 8 4 2 1 User Opening Telco 3 LEFT DATA VALUES User 32 User 31 User 30 User 29 8 4 2 1 ADDRESS 1059 LEFT RIGHT RIGHT DATA VALUES User 28 User 27 User 26 User 25 8 4 2 1 LEFT DATA VALUES User 24 User 23 User 22 User 21 8 4 2 1 ADDRESS 1058 LEFT RIGHT RIGHT DATA VALUES User 20 User 19 User 18 User 17 8 4 2 1 User Opening Telco 3 LEFT DATA VALUES User 48 User 47 User 46 User 45 8 4 2 1 ADDRESS 1061 LEFT RIGHT RIGHT DATA VALUES User 44 User 43 User 42 User 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1060 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Opening Telco 3 LEFT DATA VALUES User 64 User 63 User 62 User 61 8 4 2 1 ADDRESS 1063 LEFT RIGHT RIGHT DATA VALUES User 60 User 59 User 58 User 57 8 4 2 1 LEFT DATA VALUES User 56 User 55 User 54 User 53 8 4 2 1 ADDRESS 1062 LEFT RIGHT RIGHT DATA VALUES User 52 User 51 User 50 User 49 8 4 2 1 User Opening Telco 3 LEFT DATA VALUES User 80 User 79 User 78 User 77 8 4 2 1 ADDRESS 1065 LEFT RIGHT RIGHT DATA VALUES User 76 User 75 User 74 User 73 8 4 2 1 LEFT DATA VALUES User 72 User 71 User 70 User 69 8 4 2 1 ADDRESS 1064 LEFT RIGHT RIGHT DATA VALUES User 68 User 67 User 66 User 65 8 4 2 1 User Opening Telco 3 LEFT DATA VALUES User 96 User 95 User 94 User 93 8 4 2 1 ADDRESS 1067 LEFT RIGHT RIGHT DATA VALUES User 92 User 91 User 90 User 89 8 4 2 1 LEFT DATA VALUES User 88 User 87 User 86 User 85 8 4 2 1 ADDRESS 1066 LEFT RIGHT RIGHT DATA VALUES User 84 User 83 User 82 User 81 8 4 2 1 User Closing Telco 3 ADDRESS 1081 LEFT RIGHT blank (•) RIGHT DATA VALUES User 200 User 99 User 98 User 97 8 4 2 1 User 197 = Auto Arming/Disarming User 198 = Quickloader Arming/Disarming User 199 = Easy Arming (Opening not applicable) User 200 = Keyswitch Arming NOTE: These opening events will report as the user number shown. Also, Keyfobs 1-16 (see Easy Menu Program Driven Mode) will report as Users 180-195, respectively. User Closing Telco 3 LEFT DATA VALUES User 16 User 15 User 14 User 13 8 4 2 1 ADDRESS 1070 LEFT RIGHT RIGHT DATA VALUES User 12 User 11 User 10 User 9 8 4 2 1 LEFT DATA VALUES User 8 User 7 User 6 User 5 8 4 2 1 ADDRESS 1069 LEFT RIGHT RIGHT DATA VALUES User 4 User 3 User 2 User 1 8 4 2 1 User Closing Telco 3 LEFT DATA VALUES User 32 User 31 User 30 User 29 8 4 2 1 ADDRESS 1072 LEFT RIGHT RIGHT DATA VALUES User 28 User 27 User 26 User 25 8 4 2 1 LEFT DATA VALUES User 24 User 23 User 22 User 21 8 4 2 1 ADDRESS 1071 LEFT RIGHT RIGHT DATA VALUES User 20 User 19 User 18 User 17 8 4 2 1 User Closing Telco 3 LEFT DATA VALUES User 48 User 47 User 46 User 45 8 4 2 1 ADDRESS 1074 LEFT RIGHT RIGHT DATA VALUES User 44 User 43 User 42 User 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1073 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Closing Telco 3 LEFT DATA VALUES User 64 User 63 User 62 User 61 8 4 2 1 ADDRESS 1076 LEFT RIGHT RIGHT DATA VALUES User 60 User 59 User 58 User 57 8 4 2 1 LEFT DATA VALUES User 56 User 55 User 54 User 53 8 4 2 1 ADDRESS 1075 LEFT RIGHT RIGHT DATA VALUES User 52 User 51 User 50 User 49 8 4 2 1 User Closing Telco 3 LEFT DATA VALUES User 80 User 79 User 78 User 77 8 4 2 1 ADDRESS 1078 LEFT RIGHT RIGHT DATA VALUES User 76 User 75 User 74 User 73 8 4 2 1 LEFT DATA VALUES User 72 User 71 User 70 User 69 8 4 2 1 ADDRESS 1077 LEFT RIGHT RIGHT DATA VALUES User 68 User 67 User 66 User 65 8 4 2 1 User Closing Telco 3 LEFT DATA VALUES User 96 User 95 User 94 User 93 8 4 2 1 ADDRESS 1080 LEFT RIGHT RIGHT DATA VALUES User 92 User 91 User 90 User 89 8 4 2 1 LEFT DATA VALUES User 88 User 87 User 86 User 85 8 4 2 1 ADDRESS 1079 LEFT RIGHT RIGHT DATA VALUES User 84 User 83 User 82 User 81 8 4 2 1 CS User Reporting Codes

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 29 Global System Trouble Reporting Options GLOBAL SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1082-1116) [Default = blank (•) blank (•) from address 1082-1092] SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT/TROUBLE Burglary Alarm Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay Report Event Telco 1 Report Restore Telco 1 Report Event Telco 3 Report Restore Telco 3 GLOBAL SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") SENSOR WATCH EZM TAMPER AC FAIL LOW BATTERY 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1082-1092 LEFT ADDR RIGHT 1082 1083 1084 1085 1086 1087 1088 1091 1092 GLOBAL SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") MEMORY FAILURE COMM. BUS 1 ALARM SUPERV. TEST TIMER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 See NOTE [Default = blank (•) blank (•) from address 1094-1104] SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT/TROUBLE Burglary Alarm Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay Report Event Telco 1 Report Restore Telco 1 Report Event Telco 3 Report Restore Telco 3 GLOBAL SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. RSRVD. RSRVD. RSRVD. 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1094-1104 LEFT ADDR RIGHT blank (•) 1094 blank (•) 1095 blank (•) 1096 blank (•) 1097 blank (•) 1098 blank (•) 1099 blank (•) 1100 blank (•) 1103 blank (•) 1104 GLOBAL SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") Telemetry Failure Telemetry Trouble RSRVD. TELCO FAIL 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 [Default = blank (•) blank (•) from address 1106-1116] SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT/TROUBLE Burglary Alarm Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay Report Event Telco 1 Report Restore Telco 1 Report Event Telco 3 Report Restore Telco 3 GLOBAL SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RF TROUBLE RF TAMPER RF RCVR. TROUBLE PROGRAM CHANGE 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1106-1116 LEFT ADDR RIGHT 1106 1107 1108 1109 1110 1111 blank (•) 1112 blank (•) 1115 blank (•) 1116 blank (•) GLOBAL SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") SERVICE MESSAGE RSRVD. GUARD TOUR FAIL Digital Dialer Test 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 See NOTE ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available.

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 30 Area System Trouble Reporting Options AREA SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1120-1157) ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). AREA 2 [Default = blank (•) blank (•) from address 1130-1137] SYSTEM RESPONSE ACTIVATED BY AREA 2 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 2 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1130-1137 LEFT ADDR RIGHT 1130 1131 1132 1133 1134 1135 1137 AREA 2 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 [Default = blank (•) blank (•) from address 1140-1147] SYSTEM RESPONSE ACTIVATED BY AREA 3 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 3 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1140-1147 LEFT ADDR RIGHT 1140 1141 1142 1143 1144 1145 1147 AREA 3 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 AREA 3 AREA 4 [Default = blank (•) blank (•) from address 1150-1157] SYSTEM RESPONSE ACTIVATED BY AREA 4 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 4 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1150-1157 LEFT ADDR RIGHT 1150 1151 1152 1153 1154 1155 1157 AREA 4 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 [Defaults as circled from address 1120-1127] SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 1 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1120-1127 LEFT ADDR RIGHT 1120 1121 1122 1123 1124 1125 1127 AREA 1 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 AREA 1

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 31 AREA SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1160-1197) ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). [Default = blank (•) blank (•) from address 1160-1167] SYSTEM RESPONSE ACTIVATED BY AREA 5 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 5 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1160-1167 LEFT ADDR RIGHT 1160 1161 1162 1163 1164 1165 1167 AREA 5 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 AREA 5 AREA 6 SYSTEM RESPONSE ACTIVATED BY AREA 6 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 6 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1170-1177 LEFT ADDR RIGHT 1170 1171 1172 1173 1174 1175 1177 AREA 6 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 [Default = blank (•) blank (•) from address 1170-1177] SYSTEM RESPONSE ACTIVATED BY AREA 7 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 7 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1140-1147 LEFT ADDR RIGHT 1180 1181 1182 1183 1184 1185 1187 AREA 7 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 AREA 7 AREA 8 [Default = blank (•) blank (•) from address 1190-1197] SYSTEM RESPONSE ACTIVATED BY AREA 8 EVENT/TROUBLE Pulsed Burg. Output Burglary Output Fire Output Reset Relay Auxiliary Relay Report Alarm Telco 1 Report Alarm Telco 3 AREA 8 SYSTEM EVENT/TROUBLE LEFT DATA VALUES (CIRCLE ") RSRVD. FAIL TO CLOSE FAIL TO OPEN KEYPAD TAMPER 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1190-1197 LEFT ADDR RIGHT 1190 1191 1192 1193 1194 1195 1197 AREA 8 SYSTEM EVENT/TROUBLE RIGHT DATA VALUES (CIRCLE ") KEYPAD AUX. KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 Area System Trouble Reporting Options

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 32 ZONE OPTIONS / ZONES 1-16 (ADDRESS 1200-1386) ZONE OPTIONS 50ms Loop Response (A) 20ms Loop Response (A) Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 2-Wire Smoke Detectors (B) Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 13-16 LEFT DATA VALUES (CIRCLE ") ZN16 ZN15 ZN14 ZN13 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1302-1386 L ADDR R (•) (•) (•) (•) 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 (•) (•) 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1375 1376 1386 ZONES 9-12 RIGHT DATA VALUES (CIRCLE ") ZN12 ZN11 ZN10 ZN9 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 5-8 LEFT DATA VALUES (CIRCLE ") ZN8 ZN7 ZN6 ZN5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 1-4 RIGHT DATA VALUES (CIRCLE ") ZN4 ZN3 ZN2 ZN1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1200-1286 L ADDR R 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1275 1276 1286 Zone Options / Zones 1-16 r r r r r r r r r r r r r r r r

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 33 ! 1 ! ! 4 ! 4 ! 2 ! 2 ! 2 ZONE OPTIONS / ZONES 17-32 (ADDRESS 1402-1586) r ZONE OPTIONS Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 29-32 LEFT DATA VALUES (CIRCLE ") ZN32 ZN31 ZN30 ZN29 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1502-1586 L ADDR R 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1575 1576 1586 ZONES 25-28 RIGHT DATA VALUES (CIRCLE ") ZN28 ZN27 ZN26 ZN25 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 21-24 LEFT DATA VALUES (CIRCLE ") ZN24 ZN23 ZN22 ZN21 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 17-20 RIGHT DATA VALUES (CIRCLE ") ZN20 ZN19 ZN18 ZN17 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1402-1486 L ADDR R 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1475 1476 1486 Zone Options / Zones 17-32 See Zone Options on Page 54. r r r r r r r r r r r r r r

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 34 ! 1 ! ! 4 ! 4 ! 2 ! 2 ! 2 ZONE OPTIONS / ZONES 33-48 (ADDRESS 1602-1786) ZONE OPTIONS Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 45-48 LEFT DATA VALUES (CIRCLE ") ZN48 ZN47 ZN46 ZN45 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1702-1786 L ADDR R 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1775 1776 1786 ZONES 41-44 RIGHT DATA VALUES (CIRCLE ") ZN44 ZN43 ZN42 ZN41 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 37-40 LEFT DATA VALUES (CIRCLE ") ZN40 ZN39 ZN38 ZN37 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 33-36 RIGHT DATA VALUES (CIRCLE ") ZN36 ZN35 ZN34 ZN33 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1602-1686 L ADDR R 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1675 1676 1686 Zone Options / Zones 33-48 See Zone Options on Page 554. r r r r r r r r r r r r r r r

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 35 ! 1 ! ! 4 ! 4 ! 2 ! 2 ! 2 ZONE OPTIONS / ZONES 49-64 (ADDRESS 1802-1986) ZONE OPTIONS Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 61-64 LEFT DATA VALUES (CIRCLE ") ZN64 ZN63 ZN62 ZN61 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1902-1986 L ADDR R 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1975 1976 1986 ZONES 57-60 RIGHT DATA VALUES (CIRCLE ") ZN60 ZN59 ZN58 ZN57 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 53-56 LEFT DATA VALUES (CIRCLE ") ZN56 ZN55 ZN54 ZN53 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 49-52 RIGHT DATA VALUES (CIRCLE ") ZN52 ZN51 ZN50 ZN49 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1802-1886 L ADDR R 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1875 1876 1886 Zone Options / Zones 49-64 See Zone Options on Page 54. r r r r r r r r r r r r r r r

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 36 ! 1 ! ! 4 ! 4 ! 2 ! 2 ! 2 ZONE OPTIONS / ZONES 65-80 (ADDRESS 2002-2186) ZONE OPTIONS Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 77-80 LEFT DATA VALUES (CIRCLE ") ZN80 ZN79 ZN78 ZN77 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2102-2186 L ADDR R 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2175 2176 2186 ZONES 73-76 RIGHT DATA VALUES (CIRCLE ") ZN76 ZN75 ZN74 ZN73 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 69-72 LEFT DATA VALUES (CIRCLE ") ZN72 ZN71 ZN70 ZN69 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 65-68 RIGHT DATA VALUES (CIRCLE ") ZN68 ZN67 ZN66 ZN65 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2002-2086 L ADDR R 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2075 2076 2086 Zone Options / Zones 65-80 See Zone Options on Page 54. r r r r r r r r r r r r r r r

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 37 ! 1 ! ! 4 ! 4 ! 2 ! 2 ! 2 ZONE OPTIONS / ZONES 81-96 (ADDRESS 2202-2386) ZONE OPTIONS Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Burg. Alarm Output Pulsed Alarm Output Fire Output (Lug E9) Reset Relay Auxiliary Relay Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Sensor Watch Trouble on Open Trouble on Short Trouble on Night Open Zone Area 1 Zone Area 2 Zone Area 3 Zone Area 4 Zone Area 5 Zone Area 6 Zone Area 7 Zone Area 8 Bypass on Guard Tour Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Zone ANDing Group 5 Zone ANDing Group 6 Zone ANDing Group 7 Zone ANDing Group 8 Interior #1 Bypass Interior #2 Bypass Keypad Sounder on Alarm Fire (C) Fire Alarm Verification (C) Chime 2 ZONES 93-96 LEFT DATA VALUES (CIRCLE ") ZN96 ZN95 ZN94 ZN93 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2302-2386 L ADDR R 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2375 2376 2386 ZONES 89-92 RIGHT DATA VALUES (CIRCLE ") ZN92 ZN91 ZN90 ZN89 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 85-88 LEFT DATA VALUES (CIRCLE ") ZN88 ZN87 ZN86 ZN85 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ZONES 81-84 RIGHT DATA VALUES (CIRCLE ") ZN84 ZN83 ZN82 ZN81 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2202-2286 L ADDR R 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2275 2276 2286 Zone Options / Zones 81-96 See Zone Options on Page 54. r r r r r r r r r r r r r r r

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 38 ! 1. Select the desired zone option. ZONE OPTIONS 50ms Loop Response 10ms Loop Response Priority Priority with Bypass Auto-Bypass ! 2. Enable desired options for each zone by drawing a circle " around its corresponding binary data value. NOTE: No circle = feature disabled. 4 8 2 1 Draw Circle ZN04 ZN03 ZN02 ZN01 ! 3. Search table below for data entry. ! 4. Enter data in address locations (left and right digits). NOTE: Dark shaded data value box shows option not available. ADDRESS LOCATION L ADDR R blank (•) 1200 1 NOTE: See Direct Address Programming Example on page 19. 8 4 2 1 DIGIT VALUE DATA ENTRY Blank (.) 8 4 2 1 1 8 4 2 1 2 8 2 1 4 3 8 4 2 1 4 5 8 4 2 1 8 4 2 1 6 8 4 2 1 7 4 2 1 DIGIT VALUE DATA ENTRY 8 4 2 1 9 4 2 1 0 2 1 4 B 4 2 1 C D 4 2 1 4 2 1 E 4 2 1 F 8 8 8 8 8 8 8 8 NOTES: (A) 50ms & 20 ms Loop Response only available for zones 1-8. (B) 2-wire Smoke Detectors only available for zones 1-8. (C) If Fire Alarm Verification is selected, then Fire must also be selected. DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode. ! Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown , Zone Area 1 and Zone Area 2 are enabled for the total number of zones entered in “AREA 1 # ZONES = 08” and “AREA 2 # ZONES = 00”. ! Alarm Telco 1 is enabled for the zones if [YES] is entered for “REPORT ALL ZONES TO CENTRAL ZONES? Y/N”. ! Entry/Exit 1 and Chime are enabled for zone numbers entered in “EXIT / ENTRY ZONES ”. ! Exit/Entry Follower and Interior Bypass are enabled for zone numbers entered in “INTERIOR ZONES”. ! Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in “FIRE ZONES”. ! 2-Wire Smoke Detector is enabled for zone numbers entered in “2 WIRE FIRE ZONES”. Note: See “Number of Zones & Keypads per Area” in Easy Menu Driven program Mode. ZONE OPTIONS / ZONES 1-96 (ADDRESS 1200-2386) Zone Options / Zones 1-96 s

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 39 [Default = blank (•) blank (•)] [Default = blank (•) blank (•)] [Default = blank (•) blank (•)] SYSTEM OPTIONS (ADDRESS 2415-2419) ADDRESS 2415 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) SYSTEM OPTIONS Disable Fire Reset (Area 1) Disable Fire Reset (Area 2) Disable Fire Reset (Area 3) Disable Fire Reset (Area 4) ADDRESS 2417 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Reporting to PC Preset RESERVED Disable Auto-Unbypass on Disarming Bypass Faulted Zones RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Opening Report only after Alarm Report Closing Report only on Cond. Closing (Auto-Byp.) Include Sel./Grp. Bypass in Cond. Closing Status Status Report (Auto-Byp. Zones on Clos.) ADDRESS 2418 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Access Control (Panel) on Aux. Output Enable Burg. Output Warning on Entry Enable Manager’s Mode Start Exit Delay after Ringback RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Auto Bell Test on Arming Auto Reset after Burg. Output Timeout Suppress “Bypass” Reminder when Armed RESERVED [Default = blank (•) blank (•)] ADDRESS 2416 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) System Options RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Day Zone Watch (Area 1) Enable Day Zone Watch (Area 2) Enable Day Zone Watch (Area 3) Enable Day Zone Watch (Area 4) SYSTEM OPTIONS Disable Fire Reset (Area 5) Disable Fire Reset (Area 6) Disable Fire Reset (Area 7) Disable Fire Reset (Area 8) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Day Zone Watch (Area 5) Enable Day Zone Watch (Area 6) Enable Day Zone Watch (Area 7) Enable Day Zone Watch (Area 8) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 [Default = blank (•) blank (•)] ! 1. Select the desired option by circling "the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. ADDRESS 2419 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Disable Function-Mode Download Disable Callback Download Disable Answering- Machine Download Disable Auto-Reset on Day Zone RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Interior 1 Normally Bypassed Enable Exit-Delay Restart Reset Day Zone with Arm/Disarm Only Enable Local Alarm on First Zone “AND” Trip

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 40 SYSTEM OPTIONS (ADDRESS 2420-2422, 3874 & 3879-3881) [Default = blank (•) blank (•)] ADDRESS 2420 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) SYSTEM OPTIONS Disable Keypad Instant Button Enable Line-Fault Test Disable AC Fail Detection Telco Fail only when Armed [Default = blank (•) blank (•)] ADDRESS 2421 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Automatic Interior Bypass * Veri-phone Zones trip Aux. Relay Veri-phone Zones Priority over Alarms Aux. Output Chirp on Keyfob Arm/Disarm LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Don’t Clear Aux. Relay with Disarm Telco Answering Service Overide Disable Auto Status Veri-phone Zones trip Fire Output * Note: If “Automatic Interior Bypass” in Address 2421 is selected, then “Interior 1 Normally Bypassed” in Address 2419 must also be selected. ! 1. Select the desired option by circling "the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. System Options LEFT DATA VALUES (CIRCLE ") 1 2 4 8 RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Disable System Trouble Audible at Keypad Chime on E4 Lug Disable Code required for Func. Mode Lvl. 1 Disable Code required for Easy Bypass [Default = blank (•) blank (•)] ADDRESS 2422 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Fire Output Cadence Wireless Smoke Low Battery Resound Supervised Alarm Output Enable Smoke Detector Dirty Trouble LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Disable Area Entry Relays Disable Exit/Entry Urgency Tone at Keypad Enable Burg. Output for Keyfob Chirp Enable Burg. Output on Telco Fail only when Armed [Default = blank (•) blank (•)] ADDRESS 3874 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable GEM-PRINT Cancel Report to Telco 3 Report Wireless Trouble to Telco 1 Report Wireless Trouble to Telco 3 LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Set Time/Date RESERVED Enable Time/Date Display RESERVED [Default = blank (•) blank (•) from address 3879-3881] ADDRESS 3879-3881 LEFT ADDR RIGHT blank (•) 3879 blank (•) 3880 blank (•) 3881 ALARM/TROUBLE REPORTING CODES Wireless Low Battery Wireless Supervisory Wireless Tamper

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 41 SYSTEM OPTIONS (ADDRESS 3882-3901, 3903-3905 & 4084) ! 1. Select the desired option by circling "the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. System Options RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Disable System Trouble Audible Timeout RESERVED RESERVED RESERVED [Default = blank (•) blank (•)] ADDRESS 4084 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) blank (•) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS RESERVED RESERVED RESERVED Disable Auto Dial Tone Detection Note: Right digit is RESERVED (not used). Enter data in left digit only. Telephone Number Dialing Prefix (Digits 1-20) ADDRESS 3882-3901 (RIGHT DIGITS 1-20) 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 R R R R R R R R R R R R R R R R R R R R [Default = blank (•) blank (•)] ADDRESS 3903 LEFT RIGHT Pager Format: Re-sends of First Report [Default = blank (•) blank (•)] ADDRESS 3904 LEFT RIGHT Pager Format: Maximum Pages per Session [Default = blank (•) blank (•)] ADDRESS 3905 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) blank (•) blank (•) Note: Left digit is RESERVED (not used). Enter data in right digit only.

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 42 THIS PAGE INTENTIONALLY LEFT BLANK

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 43 RIGHT blank (•) 1 2 3 4 5 6 7 8 OPTION Not Used Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8 KEYPAD AREA ASSIGNMENT KEYPAD OPTIONS: Select options for any of the 15 keypads. * Note: For Remote Access Control only (no Arm/Disarm capability). ! 1. Select the desired option by circling " the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. KEYPAD OPTIONS (ADDRESS 2425-2454) Keypad Options [Default = blank (•) blank (•)] ADDRESS 2428 LEFT RIGHT blank (•) Keypad 4 Type & Area Assignment [Default = blank (•) 1] ADDRESS 2425 LEFT RIGHT Keypad 1 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2426 LEFT RIGHT blank (•) Keypad 2 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2427 LEFT RIGHT blank (•) Keypad 3 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2429 LEFT RIGHT blank (•) Keypad 5 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2430 LEFT RIGHT blank (•) Keypad 6 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2431 LEFT RIGHT blank (•) Keypad 7 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2432 LEFT RIGHT blank (•) Keypad 8 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2433 LEFT RIGHT blank (•) Keypad 9 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2434 LEFT RIGHT blank (•) Keypad 10 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2435 LEFT RIGHT blank (•) Keypad 11 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2436 LEFT RIGHT blank (•) Keypad 12 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2437 LEFT RIGHT blank (•) Keypad 13 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2438 LEFT RIGHT blank (•) Keypad 14 Type & Area Assignment [Default = blank (•) blank (•)] ADDRESS 2439 LEFT RIGHT blank (•) Keypad 15 Type & Area Assignment KEYPAD TYPE & AREA ASSIGNMENT: Up to 15 keypads may be programmed, if they are connected. NOTE: See Keypad Configuration Mode. By default from the factory, each keypad is configured as number 1. ! 1. Select keypad type & area assignment for each keypad from the tables shown. ! 2. Enter in corresponding right and left digit address locations above. LEFT OPTION blank (•) Burg Keypad 2 Wizard Keypad KEYPAD TYPE [Default = blank (•) blank (7) for address 2440] KEYPAD NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 KEYPAD OPTIONS LEFT DATA VALUES (CIRCLE ") TOUR STATION PANEL ACCESS EASY ARMING AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2440-2454 LEFT ADDR RIGHT 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 KEYPAD OPTIONS RIGHT DATA VALUES (CIRCLE ") Rem. Acc. Only * KEYPAD PANIC KEYPAD AUXILIARY KEYPAD FIRE 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 44 [Default = blank (•) blank (•) from address 2500-2595] USER AREA OPTIONS (ADDRESS 2500-2595) s ! 1. Select the desired user number. USER NO. 1 2 3 4 5 ! 2. Enable desired areas for each user by drawing a circle " around its corresponding binary data value. NOTE: No circle = feature disabled. 4 8 2 1 Draw Circle ZN04 ZN03 ZN02 ZN01 ! 3. Search table below for data entry. ! 4. Enter data in address locations (left and right digits). ADDRESS LOCATION L ADDR R blank (•) 2500 1 8 4 2 1 DIGIT VALUE DATA ENTRY Blank (.) 8 4 2 1 1 8 4 2 1 2 8 2 1 4 3 8 4 2 1 4 5 8 4 2 1 8 4 2 1 6 8 4 2 1 7 4 2 1 DIGIT VALUE DATA ENTRY 8 4 2 1 9 4 2 1 0 2 1 4 B 4 2 1 C D 4 2 1 4 2 1 E 4 2 1 F 8 8 8 8 8 8 8 8 A4 A3 A2 A1 User Area Options USER NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2500-2547 L ADDR R 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ! 1 ! 4 ! 4 ! 2 ! 2 USER NO. 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2548-2595 L ADDR R 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ! 4 ! 4 ! 2 ! 2 ! 1

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 45 EZM GROUP OPTIONS (ADDRESS 2600-2621) Default depends on Easy Menu Question “# OF ZNS IN AREA1” and “# OF ZNS IN AREA2”. For example, If 96 zones are used, then all 22 groups will be automatically enabled. If only 8 zones are used, then groups 1-22 will be automatically disabled. ADDRESS 2600 LEFT RIGHT blank (•) EZM Group 1 ZONES 9-12 ADDRESS 2601 LEFT RIGHT blank (•) EZM Group 2 ZONES 13-16 ADDRESS 2602 LEFT RIGHT blank (•) EZM Group 3 ZONES 17-20 ADDRESS 2603 LEFT RIGHT blank (•) EZM Group 4 ZONES 21-24 ADDRESS 2604 LEFT RIGHT blank (•) EZM Group 5 ZONES 25-28 ADDRESS 2605 LEFT RIGHT blank (•) EZM Group 6 ZONES 29-32 NOTE: Zones 1-8 are included in the control panel and Zones 9-96 (Groups 1-22) are EZM Zones (either Wireless or Hardwired). DATA ENTRIES RIGHT blank (•) 1 OPTION Not used (No EZM present) 4-Zone EZM EZM TYPE EZM GROUP OPTIONS: Up to 22 Groups of 4 Zones each may be programmed depending on the number of zones used and which EZM modules are connected. Each group represents 4 zones. ! 1. Select EZM type from the table shown. ! 2. Enter in corresponding address locations above (right digit only). NOTE: Dark shaded data value box shows option not available. [Default = blank (•) blank (•) from address 2622-2643] EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will activate the PGM Lug on the corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone EZMs are used each one is treated as TWO zone groups. NOTE: Lug goes ACTIVE (low) when ANY selected area is armed. When activated, the PGM Lug goes negative (to Ground). ! 1. Select the desired group number. ! 2. Enable desired options for each area by drawing a circle " around its corresponding binary data value. NOTE: No circle = feature disabled. ! 3. Enter data in corresponding left and right digit address locations above. ADDRESS 2606 LEFT RIGHT blank (•) EZM Group 7 ZONES 33-36 ADDRESS 2607 LEFT RIGHT blank (•) EZM Group 8 ZONES 37-40 ADDRESS 2608 LEFT RIGHT blank (•) EZM Group 9 ZONES 41-44 ADDRESS 2609 LEFT RIGHT blank (•) EZM Group 10 ZONES 45-48 ADDRESS 2610 LEFT RIGHT blank (•) EZM Group 11 ZONES 49-52 ADDRESS 2611 LEFT RIGHT blank (•) EZM Group 12 ZONES 53-56 ADDRESS 2612 LEFT RIGHT blank (•) EZM Group 13 ZONES 57-60 ADDRESS 2613 LEFT RIGHT blank (•) EZM Group 14 ZONES 61-64 ADDRESS 2614 LEFT RIGHT blank (•) EZM Group 15 ZONES 64-68 ADDRESS 2615 LEFT RIGHT blank (•) EZM Group 16 ZONES 69-72 ADDRESS 2616 LEFT RIGHT blank (•) EZM Group 17 ZONES 73-76 ADDRESS 2617 LEFT RIGHT blank (•) EZM Group 18 ZONES 77-80 ADDRESS 2618 LEFT RIGHT blank (•) EZM Group 19 ZONES 81-84 ADDRESS 2619 LEFT RIGHT blank (•) EZM Group 20 ZONES 85-88 ADDRESS 2620 LEFT RIGHT blank (•) EZM Group 21 ZONES 89-92 ADDRESS 2621 LEFT RIGHT blank (•) EZM Group 22 ZONES 93-96 GROUP NO. 1 2 3 4 5 6 7 8 9 10 11 AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2622-2632 L ADDR R 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 EZM PGM TERMINAL CONTROL GROUP NO. 12 13 14 15 16 17 18 19 20 21 22 AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2633-2643 L ADDR R 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 EZM PGM TERMINAL CONTROL EZM Group Options

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 46 AREA ARMING OPTIONS (ADDRESS 2650-2657) PRIORITY AREA ARMING: ! 1. Select the desired arming area. ! 2. Enable desired options for each priority area by drawing a circle " around its corresponding binary data value. NOTE: No circle = feature disabled. ! 3. Enter data in corresponding left and right digit address locations above. NOTE: Dark shaded data value box shows option not available. [Default = blank (•) blank (•) from address 2650-2657] ARMING AREA AREA 1 AREA 2 AREA 3 AREA 4 AREA 5 AREA 6 AREA 7 AREA 8 AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2650-2657 L ADDR R 2650 2651 2652 2653 2654 2655 2656 2657 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 PRIORITY AREA ARMING REMOTE ACCESS LOGGING (ADDRESS 3184) REMOTE ACCESS LOGGING: Enable logging of every keypad access event. ! 1. Select the desired option by circling "the data values for each digit (left and right). ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available. Area Arming Options & Remote Access Logging [Default = blank (•) blank (•)] ADDRESS 3184 LEFT DIGIT (SUM OF DATA VALUES) RIGHT DIGIT (SUM OF DATA VALUES) LEFT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Keypad 5 Enable Keypad 6 Enable Keypad 7 Enable Keypad 8 RIGHT DATA VALUES (CIRCLE ") 1 2 4 8 SYSTEM OPTIONS Enable Keypad 1 Enable Keypad 2 Enable Keypad 3 Enable Keypad 4

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 47 AREA OUTPUT CONTROL OPTIONS (ADDRESS 2700-2739) AREA OUTPUT TURNS OFF UPON DISARM: Select options for any of the 5 Outputs per area when disarming a particular area. ! 1. Select the desired option by circling " the data values for left and right digits. ! 2. Add the data values (ex: 15=1+2+4+8) from the selected options. ! 3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available. Area Output Control [Default = 2700 (•1) 2708 (•1) ] OUTPUT SILENCED (TURNED OFF) Burglary Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2700-2732 L ADDR R 2700 2708 2716 2724 2732 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 1 TURNS OFF AREA OUTPUT AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2701-2733 L ADDR R 2701 2709 2717 2725 2733 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 2 TURNS OFF AREA OUTPUT [Default = blank (•) blank (•) from address 2702-2735] OUTPUT SILENCED (TURNED OFF) Burglary Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2702-2734 L ADDR R 2702 2710 2718 2726 2734 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 3 TURNS OFF AREA OUTPUT AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2703-2735 L ADDR R 2703 2711 2719 2727 2735 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 4 TURNS OFF AREA OUTPUT [Default = blank (•) blank (•) from address 2704-2737] OUTPUT SILENCED (TURNED OFF) Burglary Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2704-2736 L ADDR R 2704 2712 2720 2728 2736 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 5 TURNS OFF AREA OUTPUT AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2705-2737 L ADDR R 2705 2713 2721 2729 2737 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 6 TURNS OFF AREA OUTPUT [Default = blank (•) blank (•) from address 2706-2739] OUTPUT SILENCED (TURNED OFF) Burglary Output Pulsed Burg. Output Fire Output Reset Relay Auxiliary Relay AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2706-2738 L ADDR R 2706 2714 2722 2730 2738 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 7 TURNS OFF AREA OUTPUT AREAS 5-8 LEFT DATA VALUES (CIRCLE ") A8 A7 A6 A5 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2707-2739 L ADDR R 2707 2715 2723 2731 2739 AREAS 1-4 RIGHT DATA VALUES (CIRCLE ") A4 A3 A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 8 TURNS OFF AREA OUTPUT

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 48 RF RECEIVERS & SUPERVISORY TIMER OPTIONS (ADDRESS 3776 & 3760-3775) Default for Number of Receivers depends on Easy Menu Question for RF Transmitters. ADDRESS 3776 LEFT RIGHT blank (•) Number of RF Receivers DATA ENTRIES RIGHT blank (•) 1 2 3 4 RF Receiver(s) None 1 2 3 4 RF RECEIVERS: Up to 4 RF Receivers may be programmed. NOTE: This adds wireless capability to the system, increasing up to 255 the number of zones. ! 1. Select the number of receivers from the table shown. ! 2. Enter in corresponding right digit address location shown (left digit is not used). [Default = blank (•) blank (•) from address 3760-3767] ADDRESS 3760-3767 LEFT ADDR RIGHT 3760 3761 3762 3763 3764 3765 3766 3767 RF SUPERVISORY TIMER RF TRANSMITTER Type 0 Window/Door, 2 Pt. Type 1 Window/Door, 2 Pt. Type 2 Window/Door, 2 Pt. Type 3 Window/Door, 2 Pt. Type 4 Window/Door, 4 Pt. Type 5 PIR Type 6 PIR Type 7 Smoke Detector [Default = blank (•) blank (•) from address 3768-3775] ADDRESS 3768-3775 LEFT ADDR RIGHT 3768 3769 3770 3771 3772 3773 3774 3775 RF SUPERVISORY TIMER RF TRANSMITTER Type 8 Smoke Detector Type 9 Keyfob Type A Dual Tech. Type B Keyfob Type C Window/Door, 4 Pt. Type D PIR Type E Smoke Detector Type F Napco Glass Break DATA ENTRIES LEFT RIGHT blank (•) blank (•) blank (•) 1 blank (•) 2 blank (•) 3 blank (•) 4 blank (•) 5 blank (•) 6 blank (•) 7 blank (•) 8 blank (•) 9 blank (•) 0 blank (•) B blank (•) C blank (•) D blank (•) E blank (•) F 1 blank (•) 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 0 1 B 1 C 1 D 1 E 1 F 2 blank (•) 2 1 2 2 2 3 2 4 2 5 DELAY 0 min. 30 min. 60 min. 90 min. 120 min. 150 min. 180 min. 210 min. 240 min. 270 min. 300 min. 330 min. 360 min. 390 min. 420 min. 450 min. 480 min. 510 min. 540 min. 570 min. 600 min. 630 min. 660 min. 690 min. 720 min. 750 min. 780 min. 810 min. 840 min. 870 min. 900 min. 930 min. 960 min. 990 min. 1020 min. 1050 min. 1080 min. 1110 min. RF SUPERVISORY TIMERS DATA ENTRIES LEFT RIGHT 2 6 2 7 2 8 2 9 2 0 2 B 2 C 2 D 2 E 2 F 3 blank (•) 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 0 3 B 3 C 3 D 3 E 3 F 4 blank (•) 4 1 4 2 4 3 4 4 4 5 4 6 F F DELAY 1140 min. 1170 min. 1200 min. 1230 min. 1260 min. 1290 min. 1320 min. 1350 min. 1380 min. 1410 min. 1440 min. 1470 min. 1500 min. 1530 min. 1560 min. 1590 min. 1620 min. 1650 min. 1680 min. 1710 min. 1740 min. 1770 min. 1800 min. 1830 min. 1860 min. 1890 min. 1920 min. 1950 min. 1980 min. 2010 min. 2040 min. 2070 min. 2100 min. 7650 min. = 127 Hr., 30 min. RF SUPERVISORY TIMERS RF SUPERVISORY TIMERS: RF Supervisory Timers may be programmed for each type of transmitter used. A transmitter will send a transmission every time it is tripped, when there is NO activity, the transmitter sends a status transmission about once an hour. If the receiver does NOT receive ANY signal (a trip or a status) from a transmitter in the time specified for transmitter type, a system trouble “RF SUPERVISORY FAILURE” will be displayed at the keypad. ! 1. Select timer delay from the table shown. Timers are programmed in increments of 30 minutes each. Valid entries are 03-FF, 90 minutes-7650 min (127 hr,30 min). WARNING: Timers have uncertainty of +/-30 minutes. Do not use entries 0-2 (shaded areas). ! 2. Enter in corresponding address locations above (left and right digits). ! 3. For a desired timer not listed do the following: A. Choose a desired timer (intervals of 30), ex: 3000 min. (50 Hours) B. Divide it by 30, ex: 3000/30 = 100 C. Divide it by 16 6 Quotient Left Digit 16 100 96 4 Remainder Right Digit NOTE: These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy Menu Driven Mode Programming). RF Receivers & Supervisory Timer Options

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 49 SYSTEM RESET OPTIONS (ADDRESS 4091-4093) Clear Dealer Program (Erases Dealer Program) This erases the dealer program. Use this feature to start a customized default program. Access address 4091, then press the Jbutton. Data entry is not allowed. NOTE: Enter Easy Menu Driven Program Mode to program system again. GEM-RP1CAe2 Keypad 4091 XX GEM-RP2ASe2 Keypad 4091XX Cold Start (Erases Entire Program) This erases the entire program (codes, schedules, foreign language configuration, etc), leaving the panel as it came right out of the box. Access address 4093, then press the J button. Data entry is not allowed. NOTE: Some features (schedules, language configuration) can only be re-programmed with the Downloading Software. GEM-RP1CAe2 Keypad 4093 XX GEM-RP2ASe2 Keypad 4093XX System Reset Options

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 50 USER PROGRAM MODE PRELIMINARY INFORMATION The User Program Mode is covered in detail in the operating instructions for the keypad in use. ! Only Keypad #1 may be used for programming, however this keypad may be located in any area. ! The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after power-up or while any area is armed. ! After entering codes or data, press the save Jbutton. Data will not be stored into memory unless this button is pressed. ! If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound. Press the C button to silence the sounder and exit the User Program Mode. ACCESSING USER PROGRAM MODE USER CODES Up to 195 User Codes may be programmed. NOTE: In this mode, only the code is programmable; the accompanying Area Options must be programmed in the Dealer Program Mode (see page 9). ! Use the A button to place the cursor over the User Number. ! Enter a User Number (001–195) using the number buttons. The cursor will then advance to the User Code and read the existing code, if any. GEM-RP1CAe2 Keypad (Direct Entry) ENTER USER CODE 001 123___ -_ _ -__ R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X ENTER USER CODE ����������������� U01 123___ - _1 - __ User Program Mode: Accessing Program Mode 1. Press EEEEEE A 2. Press g Until “ACTIVATE PROGRAM Y/N” appears on LCD screen. 3. Press F To Enter User Program Mode 4. Press C To Exit User Program Mode when finished ! Enter the new User Code using the number buttons (0-9). If an old code is displayed, program over it. To erase the digit at the cursor, press G 0 button. ! Press the Jbutton to save the code in memory. ! Repeat this procedure for each user. To proceed to Zone-Description programming, press the NEXT (E) button. NOTE: All 195 User Codes may be keypad programmed in both User and Dealer program modes. Programming User Codes User Code NOT USED To Program User Codes 1. Set Cursor Position using the A button. 2. Enter 2-digit User Number (01-96) directly using number buttons (0-9). 3. Enter Code (1-6 digits) directly using number buttons (0-9). 4. Press the Jbutton to save each code. NOTE: Press G 0 button to clear character at cursor. To continue press E or F button. 0 0

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 51 ZONE DESCRIPTIONS Enter an identifying description for each zone. Buttons 1 and 2 set the cursor position; buttons 3 and 6 scroll numbers, letters, punctuation marks, etc. ! Position the cursor over the displayed Zone Number (i.e., “01”) using buttons 1 and 2. ! Change the Zone Number using buttons 3 and 6. ! Position the cursor over the first character of the description field. Advancing the cursor between characters, program a description of up to two lines for the new zone using buttons 3 and 6. ! Press the Jbutton to save. Advance to the next zone as in Steps 1 and 2 above and repeat this procedure until all zones have been programmed. NOTE: All 255 Zone Descriptions may be keypad programmed in both User and Dealer program modes. Programming Zone Descriptions To Program Zone Descriptions 1. Set the Cursor Position using buttons 1 and 2. 2. Select characters for zone description using buttons 3 and 6. 4. Press the Jbutton to save each descriptor. NOTE: Press G 0 button to clear character at cursor. To continue press E or F button. 001-_____________ ________________ User Program Mode: Zone Descriptions

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 52 KEYPAD CONFIGURATION MODE This section will focus on configuring the GEM-RP1CAe2 and GEM-RP2ASe2 Keypads. If there is more than one keypad in the system, only Keypad No. 1 may be used for programming. KEYPAD INSTALLATION Each must be assigned an address number (1–15) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation. GEM-RP1CAe2 - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output. A GEM-RP1CAe2 is recommended for use as Keypad #1. CONFIGURING THE KEYPADS A total of up to 15 keypads may be connected to the panel. Configuring the GEM-RP1CAe2 Keypad Each GEM-RP1CAe2 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d) compatibility number; (e) EZM address; and (f) zone response. To enter the GEM-RP1CAe2 Configuration Mode: 1. Move jumper JP5 (located at the upper-right corner of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom two). NOTE: See Wiring Diagram on page 80. 2. After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address. 3. Press 11123 A and proceed as follows. (Repeat the following procedure for all keypads.) Keypad Tactile Beep Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed, indicating that the tactile beep, which sounds when any button is pressed, is on. To turn off the tactile beep, press the Jbutton (the Jbutton will toggle the tactile beep on and off). Press the A button to continue or press the C button to exit. Entry Sounder To turn off the keypad sounder during entry time, press the Jbutton (the Jbutton will toggle the tactile beep on and off). Press the A button to continue or press the C button to exit. Keypad Address If more than one keypad is installed, each must be assigned a unique keypad address (that is, no two keypads may be numbered alike): ! keypads must be numbered consecutively (missing numbers are not permitted) ! only Keypad No. 1 may be used for programming. To assign the keypad number, proceed as follows: 1. Enter the assigned keypad number 01–15, then press the Jbutton to save. A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the A button to continue or press the C button to exit. KEYPAD BEEP ON ENTRY SOUNDER ON KEYPAD ADDRESS 01 NORMAL KEYPAD CONFIGURE R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS SYSTEM ARMED 01/01/97 12:00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA # OF ZONES IN AREA 1 ENTER # ZONES X X KEYPAD BEEP ON Keypad Configuration Mode: Configuring the Keypads

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 53 Compatibility Number The compatibility number is a 4-digit security code that, if programmed into both the control panel and each GEM-RP1CAe2 keypad, dedicates the keypad to only that panel. That is, (a) similar keypads not having the correct compatibility number will not operate in the system and (b) a keypad may not be removed for use on a system with a different compatibility number. Press the A button to continue or press the C button to exit. EZM Address The keypad's internal EZM (Expansion Zone Module) may be utilized to provide four additional wired zones. Whether used alone or in conjunction with optional GEM-EZM series modules or other keypad EZMs, it must be assigned a unique address (or Group number, see Keypad Programming Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the “EZM ADDRESS 00” display. In multiple-EZM systems, enter an assigned group number “01” through “22”. (Each EZM must have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the Jbutton. Press the A button to continue or press the C button to exit. Zone Response The normal loop response of each keypad expansion zone is 750mS, however the response time of any zone can be reduced to 50mS as follows. 1. Of the following, circle the number(s) in parentheses associated with the zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8) 2. Add up the circled numbers. 3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the Jbutton. Example. Change Zones 2, 3 and 4 to 50mS response. 1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8). 2. Add up the circled numbers: 2 + 4 + 8 = 14. 3. Enter “14” at the keypad, then press the Jbutton. Press the A button to continue or press the C button to exit the Keypad Configuration Mode (display will read “01 OUT OF SYSTEM”). Then replace Jumper JP5 across Pins 1–2 (top two). NEW COMPAT# 0000 EZM ADDRESS 01 ZONE RESPONSE 00 Keypad Configuration Mode: Configuring the Keypads

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 54 KEYPAD PROGRAMMING MODES Note: ! 1. Functions that are not active, not programmed and/or not applicable to user’s authority level will be suppresses and will not display. ! 2. Many functions will not be displayed (such as: “DISPLAY ZN FAULTS”). It will require a faulted zone to display. 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA Scroll Down Scroll Up Exit Yes No Press Abutton FUNCTION LEVEL (A) DISPLAY ZN FAULTS 1 DISPLAY ZN BYPASSED 1 DISPLAY ZN DIRECTORY 1 ACTIVE BELL TEST 1 DISPLAY PHONE #’S 1 DISPLAY SYS TRBL 1 DISPLAY FIRE ALARM 1 DISPLAY FIRE TRBL 1 DISPLAY OP/CL 3 ACTIVATE OVERVIEW 3 (B) ACTIVATE CHIME 1 ACTIVATE WATCH 2 ACTIVATE GUARD TOUR 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND (C) ACTIVATE LOCATE (C) EZM ZONE FIND (C) FUNCTION LEVEL (A) ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG (D) 3 DISPLAY TOTAL LOG (D) 3 DISPLAY FIRE LOG (D) 3 DISPLAY OP/CL LOG (D) 3 DISPLAY SYSTEM LOG (D) 3 TO ARM IN 1-4HRS 2 DISPLAY AUTO ARM SCHD 3 ACTIVATE PROGRAM 3 (B) ACTIVATE DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 RELAY CONTROL 1 FUNCTION MODE (A) Minimum level required to access function (B) Level 3 code with appropriate option (C) Requires dealer code (E) Initial Configuration only; suppressed thereafter Keypad Programming Modes: Function Mode

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 55 Keypad Commands 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA Scroll Down Scroll Up Exit Yes No Enter Dealer Code FUNCTION LEVEL (A) DISPLAY ZN FAULTS 1 DISPLAY ZN BYPASSED 1 DISPLAY ZN DIRECTORY 1 ACTIVE BELL TEST 1 DISPLAY PHONE #’S 1 DISPLAY SYS TRBL 1 DISPLAY FIRE ALARM 1 DISPLAY FIRE TRBL 1 DISPLAY OP/CL 3 ACTIVATE OVERVIEW 3 (B) ACTIVATE CHIME 1 ACTIVATE WATCH 2 ACTIVATE GUARD TOUR 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND (C) ACTIVATE LOCATE (C) EZM ZONE FIND (C) FUNCTION LEVEL (A) ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG (D) 3 DISPLAY TOTAL LOG (D) 3 DISPLAY FIRE LOG (D) 3 DISPLAY OP/CL LOG (D) 3 DISPLAY SYSTEM LOG (D) 3 TO ARM IN 1-4HRS 2 DISPLAY AUTO ARM SCHD 3 ACTIVATE PROGRAM 3 (C) ACTIVATE DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 RELAY CONTROL 1 DEALER MODE Press Abutton EASY MENU PROGRAM MODE (A) Minimum level required to access function (B) Level 3 code with appropriate option (C) Requires dealer code (D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads (E) Initial Configuration only; suppressed thereafter Keypad Programming Modes: Dealer Mode

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 56 Keypad Commands 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA Set Cursor Exit Yes/ Scroll Down No/ Scroll Down Execute FUNCTION AREA 1 # OF ZONES (E) AREA 2 # OF ZONES (E) FIRE ZONE NUMBERS 2 WIRE FIRE ZONE NUMBERS REPORT ALL ZONES TO CENTRAL? Y/N (E) EXIT/ENTRY ZONE NUMBERS INTERIOR ZONE NUMBERS AREA 1 # OF KEYPADS AREA 2 # OF KEYPADS CENTRAL PHONE NO. ACCOUNT # (_ _ _ _) RCVR FORMAT ENTER USER CODE ENTER ZONE DESCRIPTIONS RF XMITTER ID CODE # + POINTS KEY FOB ID CODE # + OPTIONS ENTER DATE (MM/DD/YY) ENTER TIME (HH:MMA/P) ENTER DEALER CODE EASY MENU MODE (A) Minimum level required to access function (B) Level 3 code with appropriate option (C) Requires dealer code (D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads (E) Initial Configuration only; suppressed thereafter Press Cbutton (at any time) DIRECT ADDRESS PROGRAM MODE Keypad Programming Modes: Easy Menu Mode

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 57 Keypad Commands 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT/YES PRIOR/NO AREA Scroll Down/ Set Cursor Scroll Up Exit Yes No Execute Enter User Code FUNCTION LEVEL (A) DISPLAY ZN FAULTS 1 DISPLAY ZN BYPASSED 1 DISPLAY ZN DIRECTORY 1 ACTIVE BELL TEST 1 DISPLAY PHONE #’S 1 DISPLAY SYS TRBL 1 DISPLAY FIRE ALARM 1 DISPLAY FIRE TRBL 1 DISPLAY OP/CL 3 ACTIVATE OVERVIEW 3 (B) ACTIVATE CHIME 1 ACTIVATE WATCH 2 ACTIVATE GUARD TOUR 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND (C) ACTIVATE LOCATE (C) EZM ZONE FIND (C) FUNCTION LEVEL (A) ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG (D) 3 DISPLAY TOTAL LOG (D) 3 DISPLAY FIRE LOG (D) 3 DISPLAY OP/CL LOG (D) 3 DISPLAY SYSTEM LOG (D) 3 TO ARM IN 1-4HRS 2 DISPLAY AUTO ARM SCHD 3 ACTIVATE PROGRAM 3 (B) ACTIVATE DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 RELAY CONTROL 1 USER MODE Press Abutton USER CODES (A) Minimum level required to access function (B) Level 3 code with appropriate option (C) Requires dealer code (D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads (E) Initial Configuration only; suppressed thereafter ZONE DESCRIPTIONS (01-96) Press Cbutton (at any time) Keypad Programming Modes: User Mode DATE AND TIME

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 58 KEYPAD CONFIGURATION MODE GEM-RP1CAe2 KEYPADS Press Abutton Enter Factory Code: 11123 Configure: • Keypad Beep ON/OFF • Entry Sounder • Keypad Address 01 • New Compat# 000 ** • EZM Address 00 • Zone Response 00 • Program Control Message# 1 Press Cbutton (“01 OUT OF SYSTEM”) Return Jumper JP5 * from Pins 2-3 to Pins 1-2 (“SYSTEM READY”) Move Jumper JP5 * from Pins 1-2 to Pins 2-3 (Wait about 15 seconds: “OUT OF SYSTEM”) * JP5 is located at the top-right corner of the circuit board. ** If a Compatibility Number other than “0000” is programmed, “OLD COMPAT# XXXX” is displayed. Keypad Programming Modes: Keypad Configuration Mode

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 59 PROGRAMMING OPTIONS INDEX PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER 10ms Loop Response Direct Address 1201 32 - 37 1400hz Handshake/Kissoff Direct Address 0526,0551 & 0576 21 2300hz Handshake/Kissoff Direct Address 0526,0551 & 0576 21 24-Hour Zone (Zone Option) Direct Address 1210, 1310, 1410 & 1510 32 - 37 2-Wire Smoke Detectors (Zone Option) Direct Address 1252 32 3/1 With Extended Restores Direct Address 0526,0551 & 0576 21 50ms Loop Response Direct Address 1200 32 - 37 Abort Delay per zone Direct Address 1222, 1322, 1422 & 1522 32 - 37 Abort Delay Timeout Direct Address 2406 35 AC Fail Report Delay Direct Address 2408 19 Access Control (Panel) On Aux. Output Direct Address 2418 39 Alarm On Day Zone Direct Address 1226, 1326 1426 & 1526 32 - 37 Alarm Restore Report Code Direct Address 0860 24 Alarm Restore 1 (Zone Option) Direct Address 1228, 1328, 1428 & 1528 32 - 37 Alarm Restore 3 (Zone Option) Direct Address 1236, 1336, 1436 & 1536 32 - 37 Alarm Supervisory Report Code Direct Address 0871 25 Alarm Telco 1 (Zone Option) Direct Address 1227, 1327, 1427 & 1527 32 - 37 Alarm Telco 3 (Zone Option) Direct Address 1235, 1335, 1435 & 1535 32 - 37 Ambush Report Code Direct Address 0900 25 Ambush (Keypad Option) Direct Address 2440-2454 43 Ambush User Code Direct Address 0495 20 Answering Machine P/U W/O Line Seizure Direct Address 2417 39 Area Output Turns Off Upon Disarm Direct Address 2700-2733 47 Area System Trouble Reporting Options Direct Address 1120-1137 46 & 47 Auto Bell Test On Arming Direct Address 2418 39 Auto Disarm Rearm Delay Direct Address 4083 20 Auto Download Id No. Direct Address 1023 22 Auto Reset (Zone Option) Direct Address 1219, 1319, 1419 & 1519 32 - 37 Auto Reset After Burg. Output Timeout Direct Address 2418 39 Auto-Bypass (Zone Option) Direct Address 1204, 1304, 1404 & 1504 32 - 37 Auto-Bypass Re-Entry (Zone Option) Direct Address 1207, 1307, 1407 & 1507 32 - 37 Automatic Interior Bypass Direct Address 2421 24 Aux. Output Access Control Timeout Direct Address 2402 19 Aux. Output Chirp On Keyfob Arming Direct Address 2421 24 Aux. Output Timeout Direct Address 2401 20 Auxiliary KP Report Code Direct Address 0903 25 Auxiliary Relay (Zone Option) Direct Address 1215, 1315, 1415 & 1515 32 - 37 Backup Report On Telco 2 Direct Address 1027 25 Burg. Alarm Output (Zone Option) Direct Address 1211, 1311, 1411 & 1511 32 - 37 Burg. Alarm Output Timeout Direct Address 2403 20 Bus Failure Report Code Direct Address 0872 25 Bypass Faulted Zones Direct Address 2417 39 Callback Telephone No. Select Direct Address 1022 22 Callback Telephone Number 1 Direct Address 0600-0619 22 Callback Telephone Number 2 Direct Address 0625-0644 22 Cancel Next Test Timer On Any Report Direct Address 1027 25 Cancel Report Code Direct Address 0859 24 Cancel Window Time Direct Address 4082 20 Central Station Receiver 1 Account Number Easy Menu Driven N/A 7 Central Station Receiver 1 Format Easy Menu Driven N/A 8 Central Station Receiver 1 Telephone Number Easy Menu Driven N/A 7 Chime (Zone Option) Direct Address 1221, 1321, 1421 & 1521 32 - 37 Chime On E4 Lug Direct Address 2420 24 Chime Timeout Direct Address 2407 19 Clear Dealer Program Direct Address 4091 49 Closing Report Code Direct Address 0864 24 Closing Report Only On Cond. Closing (Auto-Byp.) Direct Address 2417 39 Cold Start Direct Address 4093 49 Conditional Closing Report Code Direct Address 0865 24 CS Receiver 1 Format Direct Address 0525 21 CS Receiver 1 Options Direct Address 0526 21 CS Receiver 1 Telephone Number Direct Address 0527-0546 22 CS Receiver 2 Format Direct Address 0550 21 CS Receiver 2 Options Direct Address 0551 21 CS Receiver 2 Telephone Number Direct Address 0552-0571 22 Programming Options Index

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 60 Programming Options Index PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER CS Receiver 3 Format Direct Address 0575 21 CS Receiver 3 Options Direct Address 0576 21 CS Receiver 3 Telephone Number Direct Address 0577-0596 22 CS System Report Options Direct Address 1027 25 CS Telco 1 Subscriber Event Id Number Direct Address 0682-0713 23 CS Telco 1 Subscriber Event Id Number (System) Direct Address 0714-0717 23 CS Telco 1 Subscriber Opening/Closing Id Number ) Direct Address 0650-0681 23 CS Telco 2 Subscriber Event Id Number Direct Address 0752-0783 23 CS Telco 2 Subscriber Event Id Number (System) Direct Address 0784-0787 23 CS Telco 2 Subscriber Opening/Closing Id Number Direct Address 0720-0751 23 CS Telco 3 Subscriber Event Id Number Direct Address 0822-0853 24 CS Telco 3 Subscriber Event Id Number (System) Direct Address 0854-0857 24 CS Telco 3 Subscriber Opening/Closing Id Number Direct Address 0790-0821 24 CS User Reporting Codes Direct Address 1030-1081 43 Day Zone Open (Zone Option) Direct Address 1224, 1324, 1424 & 1524 32 - 37 Day Zone Short (Zone Option) Direct Address 1225, 1325, 1425 & 1525 32 - 37 Dealer Security Code Direct Address 0500-0502 20 Digital Dialer Test Report Code Direct Address 0890 25 Disable Answering-Machine Download Direct Address 2419 39 Disable Auto Dial Tone Detection Direct Address 4084 41 Disable Auto Status Direct Address 2421 24 Disable Auto-Reset On Day Zone Direct Address 2419 39 Disable Auto-Unbypass On Disarming Direct Address 2417 39 Disable Callback Download Direct Address 2419 39 Disable Closing Reports Per Area Direct Address 1025 25 Disable Code Required For Easy Bypass Direct Address 2420 24 Disable Code Required For Func. Mode Lvl. 1 Direct Address 2420 24 Disable Exit/Entry Urgency Tone Direct Address 2422 24 Disable Fire Reset (Area 1) Direct Address 2415 39 Disable Fire Reset (Area 2) Direct Address 2415 39 Disable Function-Mode Download Direct Address 2419 39 Disable Keypad Instant Button Direct Address 2420 24 Disable System Trouble Audible at Keypads Direct Address 2420 24 Disable Opening Reports Per Area Direct Address 1024 25 Disable Wait For Handshake Direct Address 1027 25 Disable Wait For Silence Direct Address 1027 25 Don’t Clear Aux. Relay With Arm/Disarm Direct Address 2421 24 Download Security Code Direct Address 0645-0647 22 Easy Arming Direct Address 2440-2454 43 Enable Output Chirp on Keyfob Arm/Disarm Direct Address 2421 24 Enable Burg. Output for Keyfob Chirp Direct Address 2422 24 Enable Burg. Output Warning on Entry Direct Address 2418 39 Enable Burg. Output on Telco Fail only when Armed Direct Address 2422 24 Enable Day Zone Watch (Area 1) Direct Address 2416 39 Enable Day Zone Watch (Area 2) Direct Address 2416 39 Enable Exit-Delay Restart Direct Address 2419 39 Enable Line-Fault Test Direct Address 2420 24 Enable Manager’s Mode Direct Address 2418 39 Enable Reporting To PC Preset Direct Address 2417 39 Enable Smoke Detector Dirty Trouble Direct Address 2422 24 Enable User Code By Area Direct Address 2500-2595 59 Enable Zone Number On Pulse Alarm Direct Address 0526, 0551 & 0576 21 Enter Date Easy Menu Driven N/A 12 Enter Time Easy Menu Driven N/A 13 Enter User Codes Easy Menu Driven N/A 9 Enter Zone Descriptions Easy Menu Driven N/A 12 Entry Delay 1 Direct Address 0001 19 Entry Delay 2 Direct Address 0002 19 Entry/Exit 1 (Zone Option) Direct Address 1216, 1316, 1416 & 1516 32 - 37 Entry/Exit 2 (Zone Option) Direct Address 1217, 1317, 1417 & 1517 32 - 37

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 61 PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER Exit Delay Direct Address 0000 19 Exit/Entry Follower (Zone Option) Direct Address 1218, 1318, 1418, . . ., 2318 32 - 37 EZM Group Options Direct Address 2600-2621 45 EZM Pgm Armed Terminal Control Direct Address 2622-2643 45 EZM Tamper Report Code Direct Address 0876 25 Fail To Close Report Code Direct Address 0868 24 Fail To Open Report Code Direct Address 0869 24 Fire KP Reporting Code Direct Address 0902 25 Fire (Zone Option) Direct Address 1275, 1375, 1475, . . ., 2375 32 - 37 Fire Alarm Verification (Zone Option) Direct Address 1276, 1376, 1476, . . ., 2376 32 - 37 Fire Output (Lug E9) Direct Address 1213, 1313, 1413, . . ., 2313 32 - 37 Fire Output Cadence Direct Address 2422 24 Fire Output Timeout Direct Address 2405 20 Global System Trouble Reporting Options Direct Address 1082-1116 21 Handshake For Local Telemetry Direct Address 1027 25 Include Sel./Grp. Bypass In Cond. Closing Status Direct Address 2417 23 Interior 1 Normally Bypassed Direct Address 2419 23 Interior Bypass (Zone Option) Direct Address 1262, 1362, 1462, . . ., 2362 32 - 37 Key Fob Transmitters Easy Menu Driven N/A 12 Keypad Area Assignment Direct Address 2425-2439 43 Keypad Auxiliary Direct Address 2440-2454 43 Keypad Fire Direct Address 2440-2454 43 Keypad Options Direct Address 2440-2454 43 Keypad Panic Direct Address 2440-2454 43 Keypad Sounder On Alarm Direct Address 1264, 1364, 1464, . . ., 2364 32 - 37 Keyswitch Arming Direct Address 1206, 1306, 1406, . . ., 2306 32 - 37 Leading Digits For Pager Format (1st Digit) Direct Address 0520 21 Leading Digits For Pager Format (2nd Digit) Direct Address 0521 21 Local Or Central Station Reporting System Easy Menu Driven N/A 6 Memory Failure Report Code Direct Address 0873 25 Never Arm (Zone Option) Direct Address 1209, 1309, 1409, . . ., 2309 32 - 37 No EOL Resistor (Zone Option) Direct Address 1239, 1339, 1439, . . ., 2339 32 - 37 No. Rings Before Pickup Direct Address 4089 22 Number Of RF Receivers Direct Address 3776 63 Number Of Zones & Keypads Per Area Easy Menu Driven N/A 6,7 Opening Report Code Direct Address 0866 24 Opening After Alarm Reporting Code Direct Address 0867 24 Opening Report Only After Alarm Report Direct Address 2417 23 Panel AC Failure Report Code Direct Address 0875 25 Panel Access Direct Address 2440-2454 43 Panel Access Code Direct Address 0490-0492 20 Panel Low Battery Report Code Direct Address 0874 25 Panic KP Report Code Direct Address 0901 25 Power-Up Delay (Zone Option) Direct Address 1223, 1323, 1423, . . ., 2323 32 - 37 Pre-Alarm Warning (Zone Option) Direct Address 1208, 1308, 1408, . . ., 2308 32 - 37 Priority (Zone Option) Direct Address 1202, 1302, 1402, . . ., 2302 32 - 37 Priority Arming/Areas 1-8 Direct Address 2650-2657 46 Priority With Bypass (Zone Option) Direct Address 1203, 1303, 1403, . . ., 2303 32 - 37 Program Change Report Code Direct Address 0894 25 Pulse Alarm Output Timeout Direct Address 2404 20 Pulsed Alarm Output (Zone Option) Direct Address 1212, 1312, 1412, . . ., 2312 32 - 37 Rem. Acc. Only Direct Address 2440-2454 43 Remote Access Logging Direct Address 3184 46 Reset Day Zone With Arm/Disarm Only Direct Address 2419 23 Reset Output Timeout Direct Address 2400 20 Reset Relay (Zone Option) Direct Address 1214, 1314, 1414, . . ., 2314 32 - 37 Resound On Wireless Smoke Low Battery Direct Address 2419 23 RF Receiver Tamper Report Code (system) Direct Address 0896 25 RF Receiver Trouble Report Code (system) Direct Address 0895 25 RF Transmitter Low Battery Report Code (zone) Direct Address 3879 24 RF Transmitter Supervisory Report Code (zone) Direct Address 3880 24 RF Transmitter Tamper Report Code (zone) Direct Address 3881 24 RF Supervisory Timers Direct Address 3760-3775 63 RF Transmitter Points Easy Menu Driven N/A 11 RF Trouble Report Code Direct Address 0897 25 Selective Bypass (Zone Option) Direct Address 1205, 1305, 1405, . . ., 2305 32 - 37 Sensor Watch Report Code Direct Address 0877 25 Programming Options Index

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 62 PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER Sensor Watch (Zone Option) Direct Address 1240, 1340, 1440, . . ., 2340 32 - 37 Sensor Watch Delay Direct Address 4088 19 Service Message Report Code Direct Address 0893 25 Single Digit Only Direct Address 0526,0551 & 0576 21 Start Exit Delay After Ringback Direct Address 2418 39 Status Report (Auto-Byp. Zones On Clos.) Direct Address 2417 39 Sum Check Direct Address 0526,0551 & 0576 21 Supervised Alarm Output Direct Address 2422 24 Suppress “Bypass” Reminder When Armed Direct Address 2418 39 Swinger Shutdown (Zone Option) Direct Address 1220, 1320, 1420, . . ., 2320 32 - 37 Tamper Report Code Direct Address 0904 25 Telco Answering Service Overide Direct Address 2421 24 Telco Fail Only When Armed Direct Address 2420 24 Telco Line Failure Direct Address 0880 25 Telephone Dialing Prefix Direct Address 3882 - 3901 41 Telephone Line Test Delay Direct Address 2414 19 Test Timer Report Code Direct Address 0870 25 Touchtone Dialing Only Direct Address 1027 25 Touchtone Dialing W/Rotary Backup Direct Address 1027 25 Transmit “402” Opening/Closing Code Direct Address 1027 25 Trouble Report Code Direct Address 0861 24 Trouble On Night Open Direct Address 1243, 1343, 1443, . . ., 2343 32 - 37 Trouble On Open (Zone Option) Direct Address 1241, 1341, 1441, . . ., 2341 32 - 37 Trouble On Short (Zone Option) Direct Address 1242, 1342, 1442, . . ., 2342 32 - 37 Trouble Restore Direct Address 0862 24 Trouble Restore 1 (Zone Option) Direct Address 1230, 1330, 1430, . . ., 2330 32 - 37 Trouble Restore 3 (Zone Option) Direct Address 1238, 1338, 1438, . . ., 2338 32 - 37 Trouble Telco 1 (Zone Option) Direct Address 1229, 1329, 1429, . . ., 2329 32 - 37 Trouble Telco 3 (Zone Option) Direct Address 1237, 1337, 1437, . . ., 2337 32 - 37 Veri-Phone Zones Priority Over Alarms Direct Address 2421 24 Veri-Phone Zones Trip Aux. Relay Direct Address 2421 24 Veri-Phone Zones Trip Fire Output Direct Address 2421 24 Wireless Smoke Low Battery Resound Direct Address 2422 24 Zone Anding Group 1 (Zone Option) Direct Address 1254, 1354, 1454, . . ., 2354 32 - 37 Zone Anding Group 2 (Zone Option) Direct Address 1255, 1355, 1455, . . ., 2355 32 - 37 Zone Area 1 (Zone Option) Direct Address 1244, 1344, 1444, . . ., 2344 32 - 37 Zone Area 2 (Zone Option) Direct Address 1245, 1345, 1445, . . ., 2345 32 - 37 Zone Options - Zones 1 To 96 Direct Address 1200-2376 32 - 37 Zones Report Code - Zones 1 to 96 Direct Address 0910-1005 26 Programming Options Index

L NAPCO Security Systems

X GEM-X255 Programming Instructions WI1092B 9/02 ! Page 63 GEM-X255 Wiring Diagram GEM-X255 WIRING DIAGRAM GEMINI GEM-X255 WI1093 GEM-X255 WI1093 R C O M P U T E R IZE D S E C U R IT Y S Y S T E M GEMINI A R M E D S T A T U S S Y S T EM A R M ED 0 1/ 0 1/ 9 7 12:0 0 A M 1 2 4 3 5 6 7 8 9 0 A B C D E F G N EX T/YES PR IO R /N O A R E A GEM-RP1CAe2 (2 LINE LCD KEYPAD) GEM-X255 WIRING DIAGRAM 8.3 VDC 4 AH, 6 AH OR 7 AH WI1093

X GEM-X255 Programming Instructions

L NAPCO Security Systems WI1092B 9/02 ! Page 64 NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have been altered, defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO. Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be brought within the six months following the end of the warranty period. IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured to NAPCO. After repair or replacement, NAPCO assumes the cost of returning products under warranty. NAPCO shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts of God, or on which any serial numbers have been altered, defaced or removed. NAPCO will not be responsible for any dismantling, reassembly or reinstallation charges. This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, whether oral or written, are either merged herein or are expressly cancelled. NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product. Seller's warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and no obligation or liability shall arise or grow out of Seller's rendering of technical advice or service in connection with Buyer's order of the goods furnished hereunder. NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, electrical or communications disruption, it is possible for the system to fail to perform as expected. NAPCO does not represent that the product/system may not be compromised or circumvented; or that the product or system will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; nor that the product or system will in all cases provide adequate warning or protection. A properly installed and maintained alarm may only reduce risk of burglary, robbery, fire or otherwise but it is not insurance or a guarantee that these events will not occur. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer should in turn advise the consumer to take any and all precautions for his or her safety including, but not limited to, fleeing the premises and calling police or fire department, in order to mitigate the possibilities of harm and/or damage. NAPCO is not an insurer of either the property or safety of the user's family or employees, and limits its liability for any loss or damage including incidental or consequential damages to NAPCO's original selling price of the product regardless of the cause of such loss or damage. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross negligence, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. NAPCO LIMITED WARRANTY