Merging Technologies Horus Operation & User’s Manual
Read Online
Read the Merging Technologies Horus Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Horus User Manual
Horus Warranty Information ................................................................................................................... 9
Contacting Merging ................................................................................................................................. 9
Introduction to Horus ............................................................................................................................ 11
Horus block diagram ............................................................................................................................. 11
Horus modules interconnection diagram ............................................................................................ 13
Horus optional cards ........................................................................................................................................................ 16
Horus cables ........................................................................................................................................... 30
Horus key features ................................................................................................................................. 35
Horus Modules Capabilities........................................................................................................................................... 37
Horus Modules Latencies ............................................................................................................................................... 37
Installing an additional Horus I/O Module ........................................................................................... 38
Installing an additional Horus MADI Extension Module (MADM or MADS) ............................................. 39
Installing the Merging PCIe Ethernet Controller Card NET-MSC-GBEX1 ....................................... 42
Horus recommended placement in Rack ............................................................................................ 44
Horus power ON ..................................................................................................................................... 44
Horus touch screen control interface .................................................................................................. 45
Horus Menu Hierarchy .................................................................................................................................................... 45
Main Home Screen ............................................................................................................................................................ 46
Headphone Menu ............................................................................................................................................................... 46
Meters Menu ........................................................................................................................................................................ 47
Meters Settings Menu ...................................................................................................................................................... 47
IO & Sync Menu .................................................................................................................................................................. 48
Timecode Menu (I/O & Sync) ....................................................................................................................................... 49
REFS Menu (I/O & Sync) ................................................................................................................................................. 50
PreAmp Menu ..................................................................................................................................................................... 50
Setup Menu........................................................................................................................................................................... 53
Formats Menu (Setup)..................................................................................................................................................... 54
Routing Menu (Setup) ..................................................................................................................................................... 55
Modules Menu (Setup) .................................................................................................................................................... 57
Modules: MADI Sub-Menu ............................................................................................................................................. 58
Modules: AES Sub-Menu ................................................................................................................................................. 59
Modules: A/D Sub-Menu ................................................................................................................................................ 59
Modules: ADA Sub-Menu ................................................................................................................................................ 60
Modules: D/A Sub-Menu ................................................................................................................................................ 61
Modules: PT Sub-Menu ................................................................................................................................................... 62
Modules: Loopback (hidden menu, available only for debug use) ............................................................... 63
Presets Menu (Setup)....................................................................................................................................................... 64
System (Setup): .................................................................................................................................................................. 65
Network Menu (Setup) .................................................................................................................................................... 66
Info (Setup): ......................................................................................................................................................................... 67
Horus Web Control access ................................................................................................................... 68
Installing and accessing the Horus Control interface remotely ..................................................................... 68
The Horus embedded User Manual ............................................................................................................................ 72
Horus & Hapi setup examples .............................................................................................................. 74
.................................................................................................................................................................. 80
................................................................................................................................................................................. 80
........................................................................................................................................................................... 80
Block Diagram ..................................................................................................................................................................... 82
Horus Firmware update procedure ...................................................................................................... 84
Horus User Manual
Horus troubleshooting .......................................................................................................................... 88
Horus on screen Error Report ...................................................................................................................................... 88
How to provide Merging Support with a Horus debug dump file ................................................................. 90
Cannot access Horus remotely in Maintenance mode for Firmware update ........................................... 91
Firewall and Antivirus ..................................................................................................................................................... 91
Symptom: Horus does not start up or will after a few minutes ..................................................................... 92
Horus User Manual
IMPORTANT SAFETY AND
INSTALLATION INSTRUCTION
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS
WARNING – when using electric products, basic precautions should be followed, including the following:
1. Read all of the safety and installations instructions and explanation of graphic symbols before using
the product.
2. The product must be grounded. If it should malfunction or breakdown, grounding provides a path of
least resistance or electric current to reduce the risk of electric shock. This product is equipped with a
power supply cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet which is properly installed and grounded in accordance with all local
codes and ordinances.
DANGER – Improper connection of the equipment-grounding can result in a risk of electric shock. Do
not modify the plug provided with the product – if it will not fit the outlet have a proper outlet installed
by a qualified electrician. Do not use an adapter that defeats the function of the equipment-grounding
conductor. If you are in doubt as to whether the product is properly grounded, check with a qualified
serviceman or electrician.
3. Do not use this product near water – for example, near a bathtub, washbowl, kitchen sink, in a wet
basement, or near a swimming pool, or the like.
4. This product should only be used with a stand or cart that is recommended by the manufacture.
5. This product, either alone or in combination with an amplifier and speakers or headphones, may be
capable of producing sound levels that could cause permanent hearing loss. Do not operate at a high
volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the
ears, you should consult an audiologist.
6. The product should be located so that its location or position does not interfere with its proper
ventilation.
7. The product should be located away from heat sources such as radiators, heat registers, or other
products that produce heat.
8. The product should be connected to a power supply only of the type described in the operating
instructions or as marked on the product.
9. The power-supply cord of the product should be unplugged from the outlet when left unused for a
long period of time. When unplugging the power supply, do not pull on the cord, but grasp it by the
plug.
10. Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through
openings.
11. The product should be serviced by qualified service personnel when: A. The power supply cord or
plug has been damaged. Objects have fallen, or liquid has spilled into the product, or C. The product
has been exposed to rain, or D. The product does not appear to be operating normally or exhibits a
Horus User Manual
marked change in performance, or E. The product has been dropped, or the enclosure damaged.
12. Do not attempt to service the product beyond that described in the user maintenance instructions.
All other servicing should be referred to qualified service personnel.
13. WARNING - Do not place objects on the power supply cord, or place the product in a position
where anyone could trip over, walk on, or roll anything over cords of any type. Do not allow the
product to rest on or be installed over cords of any type. Improper installations of this type create the
possibility of a fire hazard and/or personal injury.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of sufficient magnitude to constitute a risk
of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing) instructions
in the literature accompanying the product.
No part of this documentation may reproduced in any form whatsoever or be stored in any data retrieval
system without prior written permission of the copyright owners.
This documentation is supplied on an as-is basis. Information contained within this documentation is
subject to change at any time without notice and must not be relied upon.
All company and product names are ™ or Registered Trademarks ® of their respective owners.
Windows 7 is a trademark of Microsoft Corporation.
Merging Technologies makes no warranties express or implied regarding the Horus embedded
software, its quality, performance, merchantability or fitness for a particular purpose. The software is
supplied “as is” you, the purchaser, are assuming the entire risk of the results of using this Merging
Technologies software.
In no circumstances will Merging Technologies, its owners, directors, officers, employees or agents be
liable to you for any consequential, incidental or indirect loss or damages including loss of time, loss of
business, loss of profits, loss of data or similar resulting from the use of or inability to use the Merging
Technologies hardware and or software or for any defect in the hardware software or documentation.
© Copyright Merging Technologies Inc. 2014. All rights reserved.
Horus User Manual
.
Horus User Manual
Environmental Limits
System Office Environment Parameter Limits
ESD 15kV per Merging Environmental Test Specification
Horus User Manual
Declaration of Conformity
According to
EMC Directive 2004/108/EC
Product
Horus
Manufacturer
Merging Technologies SA
Le Verney 4
CH-1070 Puidoux
Switzerland
Electrical Rating
90-260 VAC, 50/60 Hz, 0.2 A (at 230V)
Standards
EN 55103-1:2009, EN 55103-2:2009, EN 61000-3-
2 :2006+A1+A2, EN 61000-3-3 :2008
Detailed specifications of the tested and certified product are shown in the
following Test Report:
Test report Ref No: 16'835
Issued Date: June 2012 by Montena EMC SA
The CE label is affixed on the rear of left side of the Horus unit as per below :
Date 12 June 2012
Claude Cellier
President
Merging Technologies S.A.
Horus User Manual
Horus Warranty Information
* Replacing or adding a AD, DA or MADI module and adjusting the DA module dip switch (output) is permitted
under the supervision of a Merging sales partner. Any other modification will void the Horus warranty.
Contacting Merging
www.merging.com
Horus User Manual
HORUS BASE UNIT
75 Ω
(Switchable 75 Ω Termination)
= 35 Ω)
Ω
75 Ω
Horus User Manual
Horus optional cards
IOM-H-AD8D / AD8DP
These remotely controlled Mic/Line Input cards have set a new benchmark in analog circuitry design,
and provide additionally a Line level post Mic-pre “Direct Out” output.
Available in models that work up to 192kHz (AD8D) and DXD/DSD256 (AD8DP)
IOM-H-AD8D / AD8DP Key Features
• 8 x exceptionally transparent, Swiss designed pre-amplifiers
• Remote/Local switch to Line Level on a per channel basis
• Completely accessible remotely for all parameter changes
• Phantom Power/Phase/Low Cut switchable per channel
• Removes the need for DI boxes
• Allows build-in Mic splitting variants
• Better than 120dB dynamic range
IOM-H-AD8D / AD8DP Mic Pre-Amp + ADC
Mic Pre Max Input (Pad On / Pad Off)
+24 dBu / +13 dBu
Input Impedance (Differential, Software Switchable Per Channel)
2 kΩ / 13.6 kΩ
Input Impedance with +48V ON (Diff., Soft. Switchable Per Channel)
1.7 kΩ / 6.8 kΩ
Dynamic Range (A-weighted, typ.) , ref +10 dBu
127 dB
Gain Range (software controlled)
0 dB to +66 dB
Gain Step/Precision
0.5 dB / ±0.2 dB
THD+N Pre + A/D (20 Hz-20 kHz) @ -2 dBFS (AD8/AD8P)
< -96dB (0.0016 %) / -100 dB (0.001 %)
Interchannel Crosstalk @ 1kHz, typ.
< -125 dB
EIN @ >40 dB Gain (150Ω Source Impedance, A-weighted, typ.)
< -128 dBu
Common Mode Rejection Rate (20 Hz – 20 kHz)
> 60 dB (up to 0 dBFS)
Phantom Power (Software Switchable Per Channel)
+48V
Phase Reverse (Software Switchable Per Channel)
YES
Low Cut filter (Software Switchable Per Channel)
-12 dB/octave, 80 Hz
Line Input
Max Line Input for 0 dBFS
+24 dBu
Input Impedance (Differential)
13.6 kΩ
Dynamic Range (A-weighted, typ), ref +24 dBu
120 dB
THD+N Line+A/D (20 Hz - 20 kHz) @ -12 dBFS
< -100 dB (0.001%)
Interchannel Crosstalk @ 1kHz @ fullscale
< -120 dB
Sensitivity Range for 0 dBFS (software controlled)
-42 dBu to +24 dBu
Gain Step/Precision
0.5 dB / ±0.2 dB
Common Mode Rejection Rate (20 Hz – 20 kHz)
> 60 dB (up to 0 dBFS)
Connector Pinout
DB-25 / AES59 (Tascam Ana.)
Horus User Manual
IOM-H-AD8D/AD8DP Mic-Pre Analog Section
Frequency response +0/-0.5 dB, Line
5 Hz - 75 kHz
Frequency response +0/-2.0 dB, Line
2.5 Hz - 150 kHz
Frequency response +0/-0.5 dB, Mic
10 Hz - 100 kHz
Frequency response +0/-2.0 dB, Mic
5 Hz - 200 kHz
THD+N (1 kHz), Line/Mic at G=0dB
<-115 dB (0.00018 %)
THD+N (20 Hz-20 kHz) , Line/Mic at G=0dB
<-112 dB (0.00025 %)
Interchannel Crosstalk @ 1kHz, typ.
-135dB
5° low-end in-channel Ø deviation pt: Line
13 Hz
5° low-end in-channel Ø deviation pt: Mic
35 Hz
Interchannel phase 10 Hz - 100 kHz
< ±0.1°
IOM-H-AD8D/AD8DP Direct Out Section
Frequency response +0/-0.3dB @ Gain 40dB
10 Hz –50kHz
Max Direct Output level typ.
+24 dBu
Output Impedance (Differential)
< 100 Ω
Dynamic Range (A-weighted, typ)
133 dB
THD+N (1 kHz) @ +10dBu
< -120dB (0.0001 %)
Input Connector Pinout
DB-25 / AES59 (Tascam Ana.)
Direct Output Connector Pinout
DB-25 / AES59 (Tascam Ana.)
Gain behavior of the Direct Out section
As the Direct Out output is taken just after the Mic-pre analog section, the gain adjustments are not as
smooth and linear as after the digital conversion. The figure below shows the behaviour of the gain on
the Direct Out (in blue) compared to the gain on the digital side (in red).
Note: on the Direct Out the maximum available gain is + 40.1 dB.
Horus User Manual
Mic / Line pad
-11dB
48V phantom
power
On / Off
Preamp
analog gain
0 to + 40dB
AD8D / AD8DP run 1 to run 8
A/D converter
Analog input
Digital gain
Direct Out
+18dBu
Analog output
Preamp
analog gain
0 to + 40dB
48V phantom
power
On / Off
Mic / Line pad
-11dB
AD8D / AD8DP run 9 and above
A/D converter
Analog input
Digital gain
Direct Out
+13/+24dBu
Analog output
Zin selector
2kΩ / 6.8kΩ / 13kΩ
2kΩ: dynamic mic (no phantom)
6.8kΩ: condenser mic (with phantom ON)
13.6kΩ: line input
Horus User Manual
IOM-HORUS-DA8/DA8P
The DA8 (up to 192kHz) and the DA8P (up to DSD) have been shown in testing to be consistently the
quietest multichannel D/A conversion modules available anywhere.
IOM-HORUS-DA8/DA8P Key Features
• Auto-mute circuitry for “no-pop” power cycling
• Digitally controlled trims for line up procedures
• Dynamic range of 127dB (typ.)
• Easy to set dip switches for international operating levels
IOM-HORUS-DA8/DA8P Specifications
Max Line Output @ 0 dBFS (jumpers on +24 dBu)
+24 dBu +0/-0.5 dB
Frequency response +0/-0.3dB @ fs = 48000 Hz
6 Hz – 20 kHz
Frequency response +0/-0.3dB @ fs = 2.8224 MHz (DSD)
NA / 6 Hz – 20 kHz
Frequency response +0/-3.0dB @ fs = 2.8224 MHz (DSD)
NA / 2 Hz – 50 kHz
Line Output Impedance (Differential)
100 Ω
Dynamic Range (A-weighted, typ)
126 dB
THD+N D/A (1 kHz) @ 0 dBFS (IOM-HORUS-DA8)
< -113dB (0.00022 %)
THD+N D/A (1 kHz) @ 0 dBFS (IOM-HORUS-DA8P)
< -115dB (0.00018 %)
Interchannel Crosstalk @ 1kHz, typ.
-135 dB
Connector Pinout
DB-25 / AES59 (Tascam Ana.)
Horus User Manual
Line Output Level calibration
The DA8 and DA8P modules feature both hardware level settings and a software fine adjustment to
align the Analog Output levels to whatever local/organization operational levels are mandated.
On DA8/DA8P cards from run 7 upwards, the hardware level setting is done via software through the
option “max output level” in each DA’s setting page, allowing either + 24 dBu or 18 dBu max level.
On DA8/DA8P cards prior to run 7 the hardware level setting is in the form of 4 DIP switches per output
channel
The Hardware settings will usually be set only once, at product installation, and only if the desired
Operating Line Level differs from the default ex-factory settings of +18 dBu for 0 dBFS.
Procedure for Hardware alignment (for DA8 prior to run 7):
Output Level (dBu)
+24
+18
+15
+12
Switch
S1 to S8
1
ON
ON
2
ON
ON
3
ON
ON
4
ON
ON
Horus User Manual
D/A converter
Analog Output Level
Selection
+12dB/+15dB/
+18dB/+24dB
DA8 / DA8P run 1 to run 6
Digital input
Mute Relay
DA8 / DA8P run 7 and above
Analog Output
D/A converter
Analog Output Level
Selection
+18dB/+24dB
Mute Switch
Analog Output
Digital input
Roll Off Filter
Digital
Output Attenuation
[0 .. -60dB]
Roll Off Filter
Digital
Output Attenuation
[0 .. -60dB]
Horus User Manual
IOM-H-ADA8
These remotely controlled Mic/Line Input and Output cards have broken a new barrier in terms of
compactness as well as ultra-low power consumption without compromising on the audio quality.
These cards work at sampling rates up to 192 kHz
Using those combined 8 channel Mic/Line In and Line Out cards allow the Hapi to be configured with up
to 16 channels of Analog In/Out.
IOM-H-ADA8 Key Features
• 8 x exceptionally transparent, Swiss designed pre-amplifiers
• Remote/Local switch to Line Level on a per channel basis
• Completely accessible remotely for all parameter changes
• Phantom Power/Phase/Low Cut/Impedance switchable per channel
• Dynamic range of 120dB (A-weighted, typ) on the Line inputs
• Auto-mute circuitry for “no-pop” power cycling
• Digitally controlled output trims for line up procedures
• Dynamic range of 123dB (A-weighted, typ.) on the Line outputs
IOM-H-ADA8 Specifications
IOM-H-ADA8 Mic-Pre + ADC Section
Mic Pre Max Input (Pad On / Pad Off)
+24 dBu / +13 dBu
Input Impedance (Differential, Software Switchable Per Channel)
2 kΩ / 13.6 kΩ
Input Impedance with +48V ON (Diff., Soft. Switchable Per Channel)
1.7 kΩ / 6.8 kΩ
Frequency response +0/-0.3dB @ fs = 48 kHz
10 Hz – 22 kHz
Frequency response +0/-0.3dB @ fs = 96 kHz
10 Hz – 44 kHz
Frequency response +0/-0.3dB @ fs = 192 kHz
10 Hz – 85 kHz
Dynamic Range (A-weighted, typ.), ref +13 dBu
119.5 dB
Gain Range (software controlled)
0 dB to +66 dB
Gain Step/Precision
0.5 dB / ±0.2 dB
THD+N Pre + A/D (20 Hz - 20 kHz) @ -2 dBFS
< -102 dB (0.0008 %)
Interchannel Crosstalk @ 1kHz
< -125 dB
EIN @ >40 dB Gain (150Ω Source Impedance, A-weighted)
< -128 dBu
Common Mode Rejection Rate (20 Hz – 20 kHz)
> 60 dB (up to 0 dBFS)
Phantom Power (Software Switchable Per Channel)
+48V
Phase Reverse (Software Switchable Per Channel)
YES
Low Cut filter (Software Switchable Per Channel)
-12 dB/octave, 80 Hz
IOM-H-ADA8 Line input Section
Max Line Input for 0 dBFS
+24 dBu
Input Impedance (Differential)
13.6 kΩ
Dynamic Range (A-weighted, typ.), ref +24 dBu
120 dB
THD+N Line+A/D (20 Hz - 20 kHz) @ -2 dBFS
< -102 dB (0.0008%)
Interchannel Crosstalk @ 1kHz
< -125 dB
Sensitivity Range for 0 dBFS (software controlled)
-42 dBu to +24 dBu
Gain Step/Precision
0.5 dB / ±0.2 dB
Common Mode Rejection Rate (20 Hz – 20 kHz)
> 60 dB (up to 0 dBFS)
Connector Pinout
DB-25 / AES59 (Tascam Ana.)
Horus User Manual
IOM-H-ADA8 Mic-Pre Analog Section
Frequency response +0/-0.5 dB, Line
5 Hz - 75 kHz
Frequency response +0/-2.0 dB, Line
2.5 Hz - 150 kHz
Frequency response +0/-0.5 dB, Mic
10 Hz - 100 kHz
Frequency response +0/-2.0 dB, Mic
5 Hz - 200 kHz
THD+N (1 kHz), Line/Mic at G=0dB
<-115 dB (0.00018 %)
THD+N (20 Hz-20 kHz) , Line/Mic at G=0dB
<-112 dB (0.00025 %)
Interchannel Crosstalk @ 1kHz, typ.
-135dB
5° low-end in-channel Ø deviation pt: Line
13 Hz
5° low-end in-channel Ø deviation pt: Mic
35 Hz
Interchannel phase 10 Hz - 100 kHz
< ±0.1°
IOM-H- ADA8 Line Out Section
Max Output level software switchable for 0 dBFS
+24 dBu / +18 dBu +0/-0.5 dB
Frequency response +0/-0.3dB @ fs = 48 kHz
6 Hz – 22 kHz
Frequency response +0/-3dB @ fs = 96 kHz
6 Hz – 44 kHz
Frequency response +0/-3dB @ fs = 192 kHz
6 Hz – 88 kHz
Output Impedance (Differential)
< 100 Ω
Dynamic Range (A-weighted, typ.)
123 dB
THD+N (1 kHz) @ 0dBFS
< -108 dB (0.0004 %)
Interchannel Crosstalk @ 1kHz
< -135 dB
Connector Pinout
DB-25 / AES59 (Tascam Ana.)
IOM-H-ADA8 block diagram
Zin selector
2kΩ / 6.8kΩ / 13kΩ
48V phantom
power
On / Off
Preamp
analog gain
0 to + 40dB
Mic / Line pad
-15dB
Analog input
A/D converter
Digital gain
2kΩ: dynamic mic (no phantom)
6.8kΩ: condenser mic (with phantom ON)
13.6kΩ: line input
D/A converter
Analog Output Level
Selection
+18dB/+24dB
Mute Switch
Analog Output
Digital input
Roll Off Filter
Digital
Output Attenuation
[0 .. -60dB]
MIC / LINE IN
LINE OUT
Horus User Manual
IOM-H-PT64
This module allows you to connect your Horus directly to a Pro Tools HD or Pro Tools HDX system
through its two Digilink Mini connectors. You can insert up to two modules in a device, meaning you can
manage up to 128 Channels at a time. Note that, in Horus, the cards can only be mounted in Slot 3 and
Slot 6.
Requires Firmware 3.0.5b28137 and above
IOM-H-PT64 Key Features
• Up to 64 Channels @48kHz per module (32 ch. @ 96kHz, 16 ch. @192kHz)
• Up to two IOM-H-PT64 modules in one Horus/Hapi
• Automatic Delay Compensation
• Three hardware emulation modes (Digidesign 192I/O, HDIO and HDMADI)
• Two Digilink mini connectors
Ports usage
There are two connectors on the IOM-H-PT64 module called Port 1 and Port 2. Working at 44.1/48kHz,
both Ports are enabled. Channels I/O 1-32 are carried through Port 1 and channels I/O 33-64 through
Port 2. If only 32 channels are needed, it is possible to use only Port 1 or Port 2.
With a Sample Rate of 88.2/96kHz, only Port 1 is enabled. All 32 I/O channels will be carried through
this Port.
If the Sample Rate is set to 176.4/192kHz, then all 16 I/O channels will be carried through Port 1 as
well.
If both Ports are connected, Port 1 of your IOM-H-PT64 should be connected to Port 1 on the AVID
interface and Port 2 should be connected to Port 2.
Synchronization and Word Clock
When properly configured, a Horus is able to automatically change its internal clock to match a Pro
Tools project’s Sample Rate. The proper IOM-H-PT64 module must be selected in the I/O & Sync menu
(PT 3 or PT 6 if module is in Slot 3 or 6). The Auto-follow option must be enabled in Setup -> Format
menu, and Horus will change its Internal Sample Rate automatically.
Horus User Manual
In Pro Tools, the Clock source should be set to Internal for the device emulated by the IOM-H-PT64
module (HD MADI in the following example).
Horus User Manual
Setups with multiple devices
Here are a few setups using several Pro Tools Hardware interfaces that need to be synchronized. The
other devices present in the setup can be synchronized in several different ways.
If two Horus interfaces are used in a setup, they can be synchronized through the Word Clock
connectors. To send the actual Sample Rate, the Follow SR option in Setup -> Format must be
enabled.
IOM-H-PT64
HD Card 1
Pro Tools HD/HDX
Clock Source :
Horus 1 Internal
Sync Source:
IOM-H-PT64
WCK Out
WCK In
Sync Source:
WCK
IOM-H-PT64
HD Card 2
Horus 1
Horus 2
The next setup is using Horus as the Master clock for all devices. In this case, the Clock Source must
be set to the other device’s Word Clock. The Follow SR option in Setup -> Format must be enabled.
IOM-H-PT64
HD Card 1
Pro Tools HD/HDX
Clock Source :
Other device’s WClk In
HD Card 2
Sync Source:
IOM-H-PT64
WCK Out
Additionnal HDLink
capable interfaces
Horus 1
In the following setup, an external Master Clock is used for all devices. In this case, the external Master
Clock controls the Horus Sample Rate. Hence, the external Master Clock must be set accordingly to the
Pro Tools project Sample Rate.
IOM-H-PT64
HD Card 1
Pro Tools HD/HDX
Clock Source :
External Master Clock
HD Card 2
Sync Source:
WCK
External Master
Clock
WCK In
WCK Out
Additionnal HDLink
capable interfaces
Horus 1
Horus User Manual
IOM-H-PT64 block diagram
Output Delay
Decoder
From Pro Tools
Input Delay
Encoder
To Pro Tools
To Horus
From Horus
Delay compensation
Input and Output delay are strongly dependent on the Hardware. This implies that if one records a
single source with two different devices at the same time, one will get two slightly out-of-phase tracks.
This is explained by the fact that every device has its own circuitry and different components.
To minimize this issue, Pro Tools implemented an Auto Delay Compensation feature which will
automatically shift the recording depending on the Hardware used.
The IOM-H-PT64 module was made to emulate three different Digidesign interfaces and match every
interface’s actual input/output latency (within a margin of maximum 3 samples). This chart shows what
latency to expect for different setups. Analog/Digital modules latencies are already included in these
measures.
Emulation Mode
Routing
44k1/48k
88k2/96k
176k4/192k
None
Input
-
2* smpl.
2* smpl.
2* smpl.
Output
-
2* smpl.
2* smpl.
2* smpl.
192IO
Input
From AD8D
65 smpl.
65 smpl.
65 smpl.
Output
To DA8
24 smpl.
14 smpl.
15 smpl.
HDIO
Input
From AD8D
16 smpl.
12 smpl.
11 smpl.
Output
To DA8
56 smpl.
21 smpl.
21 smpl.
HD MADI
Input
From MADI
6 smpl.
6 smpl.
7 smpl.
Output
To MADI
5 smpl.
5 smpl.
7 smpl.
* Added to the Input/Output latencies of the modules used
For the delay compensation to be working, it must be enabled in the ProTools software (Options ->
Delay Compensation).
Emulation Mode
Configures which Digidesign interface the IOM-H-PT64 module will emulate in Pro Tools. This option
does not affect the Horus routing or preamps, it will just set the Input/Output Delays as seen above.
When set to None, Pro Tools will see the module as an HD MADI, but Horus will use the minimum
latency. Therefore, Delay Compensation will not be accurate on Pro Tools in this mode.
Error AAE -6116
When Horus is configured to follow the Sample Rate asked by Pro Tools, an AAE -6116 error might
happen when opening a project with a new Sample Rate. If it happens, click OK to close the error
information. Then, when trying to play the file, the error might show again. After clicking OK, the error
should not appear again.
If this issue is too frequent, a way to avoid it is to disable the Auto-Follow option in Setup -> Formats
and change the Sample Rate on Horus by hand. This should reduce the probability of getting such an
error.
Horus User Manual
Horus cables
Connecting the analog audio Input cables to the AD8/AD8P modules
Horus User Manual
Connecting the MADI cable
Connecting the Wordclock input/output
Connecting the Sync Cable
Horus User Manual
MIDI connection:
Connecting the RAVENNA Ethernet cables
Horus User Manual
Horus key features
Modular analog interfacing
Modular Device connectivity
AD8 / AD8P Remote controlled Mic/Line A/D module
DA8 / DA8P Safety Conscious Analogue Line output Modules
ADA8 Remote controlled Mic/Line A/D module with transparent Analog output
The ADA8 work at sample rates up to 192 kHz.
HD Link with Pro Tools HD
The PT Module allows the Horus to communicate with a Pro Tools HD card. With two modules in one
interface, up to 128 channels can be recorded simultaneously.
Redundant power supply options
Redundant versus secondary Power supply (More than 3 Analog Input modules)
Horus User Manual
MADI 1
MADI 2 (Expansion Slot)
AES-EBU
Signal routing paradigm
RAVENNA IP Audio
Synchronization
Audio is not the only information that can pass down the RAVENNA connection. Horus is also able to
send sync (LTC) down the same wire to and from the Hapi unit. For more details refer to the RAVENNA
network guide available on www.merging.com
Key Specifications
Horus User Manual
Horus Modules Capabilities
Modules
AD8
AD8D
standard
AD8P
AD8DP
premium
DA8
standard
DA8P
premium
ADA8
PT64
Headphone
MADI
AES
Sampling Rates
44.1/48kHz
√
√
√
√
√
√ (64 I/O)
√
√ (64 I/O)
√
88.2/96kHz
√
√
√
√
√
√ (32 I/O)
√
√ (32 I/O)
√
176.4/192kHz
√
√
√
√
√
√ (16 I/O)
√
√ (16 I/O)
√
DXD/384kHz
√
√
√
√ (8 I/O)
DSD64
√
√
√ *
DSD128
√
√
√ *
DSD256
√
√
Horus Modules Latencies
Modules
AD standard
premium
DA standard
premium
ADA8
Input
Output
PT64
Headphone
MADI
AES
Sampling
Rates
44.1/48kHz
15 smpl.
12 smpl. *
16 smpl. 9 smpl. **
2 smpl.
15 smpl.
3 smpl.
3 smpl.
88.2/96kHz
10 smpl.
12 smpl. *
16 smpl. 9 smpl. **
2 smpl.
8 smpl.
3 smpl.
3 smpl.
176.4/192kHz
8 smpl.
12 smpl. *
13 smpl. 9 smpl. **
2 smpl.
8 smpl.
3 smpl.
3 smpl.
DXD/384kHz
8 smpl.
12 smpl. *
NA
NA
NA
8 smpl.
3 smpl.
NA
* DA Filter setting
- Slow Roll Off Filter option = 12 Samples
- Sharp Roll Off Filter option = 39 Samples
(More details available under the DA Module chapter below)
** ADA Filter setting
- Slow Roll Off Filter option = 9 Samples
- Sharp Roll Off Filter option = 38 Samples
Horus User Manual
Installing an additional Horus MADI Extension Module (MADM or MADS)
Horus User Manual
Installing the Merging PCIe Ethernet Controller Card
NET-MSC-GBEX1
Horus User Manual
Horus recommended placement in Rack
Horus power ON
Connecting the Power Cable
Horus User Manual
Horus touch screen control interface
Horus Menu Hierarchy
Horus User Manual
Meters Menu
LED indications:
Meters Settings Menu
Horus User Manual
Line Fader of 0 dB, means 0 dBFS for +24 dBu Analog signal level present at
the Line input
Line Fader of + 6 dB, means 0 dBFS for +18 dBu Analog signal level present at
the Line input
Line Fader of + 20 dB, means 0 dBFS for +4 dBu Analog signal level present at
the Line input
Line Fader of + 66 dB, means 0 dBFS for -42 dBu Analog signal level present
at the Line input
Horus User Manual
Zlo – Zhi
Mic input impedance (only available for ADA8 & AD8D/AD8DP run 9 and
above modules)
48V Phantom
Disabled Enabled
Zlo
2 kΩ
1.7 kΩ
Zhi
13.6 kΩ
6.8 kΩ
Horus User Manual
Formats Menu (Setup)
Horus can be configured in DXD/DSD and in this mode the Horus can
receive any audio data format stream and can generate DXD or DSD(64, 128
or 256) stream depending on the A/D audio data format chosen.
Horus User Manual
Routing: Configuration
Headphone - D/A - AES - MADI - PT Routing Output Source (similar)
ADA N
The ADA buttons, which become active if you have 1 or more ADA8 modules
installed in the Hapi unit, give access to the Input controls.
Loopback:
Should only be used for test purposes.
Horus User Manual
Modules Menu (Setup)
Headphone
A/D N
ADA N
The ADA buttons, which become active if you have 1 or more ADA8 modules installed in the Hapi unit,
give access to the Input controls.
D/A N
PT 3/6
MADI 1-2
AES 1-3
TimeCode
Horus User Manual
Modules: AES Sub-Menu
Output Source:
Shortcut to the Output Source Routing Page configuration
Modules: A/D Sub-Menu
Example: Setting a gain alignment of +10dB will make the Horus, Web Access
or the Pyramix PreAmps control to be offset by a scaling of +10 dB.
Module
Horus User Manual
Modules: ADA Sub-Menu
Mic Alignment:
User can offset the Mic Gain Alignment scaling from a Range of 0dB to +12dB.
Example: Setting a gain alignment of +10dB will make the Hapi, Web Access
or the Pyramix PreAmps control to be offset by a scaling of +10 dB.
Max Level
Maximum Output Level: +18 dBu or +24 dBu
Output attenuation:
Calibration of the D/A output (Range -60.0 dB to 0 dB).
Refer to the Hardware section for the D/A onboard output level calibration.
Roll Off Filter:
Sharp roll-off filter: Offers a flat frequency response up to 22kHz, within 0.2dB,
which has the tradeoff of 36 samples latency. This mode was and still is the
default one.
Slow roll-off filter: Offers a low latency of 9 samples, with the tradeoff of a
gentle frequency response attenuation starting around 16kHz and reaching -
2.5dB at 22kHz
Serial Number:
This is the place you can access all your Modules serial numbers without
having to unslot them or open the box
Type:
Module Type description
Horus User Manual
Modules: PT Sub-Menu
Emulation mode:
Selection of the Hardware emulated in Pro Tools. Latency is adapted to the
mode chosen, see detailed table in IOM-H-PT64 section.
None mode is seen as an HD MADI in Pro Tools, but has the lowest latency.
Serial Number:
Module Serial Number and Run
Output Source:
Selection of the output source sent to Pro Tools for each of the 8 groups. Any
of the digital or analog inputs can be routed to Pro Tools as well as RAVENNA
signals.
Here is an example of routing:
PT 3 (1-8): Routed on PT 3 (1-8)
PT 3 (9-16): Routed on PT 3 (9-16)
PT 3 (17-24): Routed on A/D 5 (1-8)
PT 3 (25-32): Routed on AES 1 (1-8)
PT 3 (33-40): Routed on AES 2 (1-8)
PT 3 (41-48): Routed on MADI 1 (1-8)
PT 3 (49-56): Routed on MADI 1 (9-16)
PT 3 (57-64): Routed on RAVENNA
Horus User Manual
Modules: Loopback (hidden menu, available only for debug use)
Transparency Check:
This is a Debug Utility tool that verifies the bit transparency of the audio path
Horus User Manual
Presets Menu (Setup)
can be loaded (one at a time)
Auto Save:
If enabled the save configuration will happen at every 2 minutes.
Horus User Manual
System (Setup):
The Dark option will display a black Screen Saver, mainly used when Horus
needs to be a discreet stage box.
Terminations:
75Ω for WCK: Sets 75Ω termination for the Wordclock Input.
75Ω for Video: Sets 75Ω termination for the Video reference Input. Unless the
Video Reference signal provided to the Horus is daisy-chained to other
equipment, you should always terminate your Video signal for most reliable
operation.
Horus User Manual
Horus Web Control access
Installing and accessing the Horus Control interface remotely
http://www.merging.com/products/horus/downloads
-
-
-
Horus User Manual
For other parameters, please refer to the PreAmps module description (above)
Horus User Manual
How to use the IOM-H-PT64 module with Digidesign HDIO
o
o
Horus User Manual
Manage Mic PREs from Pro Tools MAC
All details are available in the MergingVirtual Audio Device (formerly Core Audio Driver) Guide:
http://www.merging.com/products/networked-audio/downloads
Horus User Manual
Pro Tools on PC Horus / Hapi
http://www.tobias-erichsen.de/wp-content/uploads/2012/08/rtpMIDI_1_0_11_227.zip
Horus User Manual
Horus Firmware update procedure
http://www.merging.com/products/horus/downloads
Horus User Manual
http://www.merging.com/products/horus/downloads
http://www.merging.com/products/horus/downloadshttp://www.merging.com/horus/download
Horus User Manual
10)
Wrong maintenance version, must be >= 31” .
Note: A Maintenance Mode update requires a shutdown of the Horus once the update completed.
Horus User Manual
Wrong maintenance version, must be >= 31”. This means that
you must first install the latest Maintenance Firmware prior to updating to the latest Firmware
Contact us at [email protected] if your firmware update cannot be executed
Horus User Manual
Horus troubleshooting
Horus on screen Error Report
"Primary Power Supply Failure";
"Secondary Power Supply Failure";
"Two Power Supplies Required" in case of more than 3 A/D are present
"Temperature too high";
"Horus Application failure, please reboot"
"Fan failure"
"Ethernet input: GP fifo overrun";
"Ethernet input: GP descriptors fifo overrun";
Horus User Manual
"Ethernet input: Audio packet still pending";
"Ethernet input: Audio pipeline too small";
"Ethernet input: Wrong sequence number";
"Ethernet input: CRC error";
"Ethernet input: Queue mux error";
"Ethernet input: Audio buffer too small";
"Ethernet input: SSRC mismatch"
"Ethernet input: Unknown error";
"FPGA memory: Timeout";
"FPGA memory: Unknown error";
“48V power failure: all A/D 48V forced off until next reboot”
Horus User Manual
How to provide Merging Support with a Horus debug dump file
[email protected]
Horus User Manual
Cannot access Horus remotely in Maintenance mode for Firmware update
Firewall and Antivirus
Horus User Manual
Symptom: Horus does not start up or will after a few minutes