Horus User Manual

Horus Warranty Information ................................................................................................................... 9 Contacting Merging ................................................................................................................................. 9 Introduction to Horus ............................................................................................................................ 11 Horus block diagram ............................................................................................................................. 11 Horus modules interconnection diagram ............................................................................................ 13 Horus optional cards ........................................................................................................................................................ 16 Horus cables ........................................................................................................................................... 30 Horus key features ................................................................................................................................. 35 Horus Modules Capabilities........................................................................................................................................... 37 Horus Modules Latencies ............................................................................................................................................... 37 Installing an additional Horus I/O Module ........................................................................................... 38 Installing an additional Horus MADI Extension Module (MADM or MADS) ............................................. 39 Installing the Merging PCIe Ethernet Controller Card NET-MSC-GBEX1 ....................................... 42 Horus recommended placement in Rack ............................................................................................ 44 Horus power ON ..................................................................................................................................... 44 Horus touch screen control interface .................................................................................................. 45 Horus Menu Hierarchy .................................................................................................................................................... 45 Main Home Screen ............................................................................................................................................................ 46 Headphone Menu ............................................................................................................................................................... 46 Meters Menu ........................................................................................................................................................................ 47 Meters Settings Menu ...................................................................................................................................................... 47 IO & Sync Menu .................................................................................................................................................................. 48 Timecode Menu (I/O & Sync) ....................................................................................................................................... 49 REFS Menu (I/O & Sync) ................................................................................................................................................. 50 PreAmp Menu ..................................................................................................................................................................... 50 Setup Menu........................................................................................................................................................................... 53 Formats Menu (Setup)..................................................................................................................................................... 54 Routing Menu (Setup) ..................................................................................................................................................... 55 Modules Menu (Setup) .................................................................................................................................................... 57 Modules: MADI Sub-Menu ............................................................................................................................................. 58 Modules: AES Sub-Menu ................................................................................................................................................. 59 Modules: A/D Sub-Menu ................................................................................................................................................ 59 Modules: ADA Sub-Menu ................................................................................................................................................ 60 Modules: D/A Sub-Menu ................................................................................................................................................ 61 Modules: PT Sub-Menu ................................................................................................................................................... 62 Modules: Loopback (hidden menu, available only for debug use) ............................................................... 63 Presets Menu (Setup)....................................................................................................................................................... 64 System (Setup): .................................................................................................................................................................. 65 Network Menu (Setup) .................................................................................................................................................... 66 Info (Setup): ......................................................................................................................................................................... 67 Horus Web Control access ................................................................................................................... 68 Installing and accessing the Horus Control interface remotely ..................................................................... 68 The Horus embedded User Manual ............................................................................................................................ 72 Horus & Hapi setup examples .............................................................................................................. 74 .................................................................................................................................................................. 80 ................................................................................................................................................................................. 80 ........................................................................................................................................................................... 80 Block Diagram ..................................................................................................................................................................... 82 Horus Firmware update procedure ...................................................................................................... 84

Horus User Manual

Horus troubleshooting .......................................................................................................................... 88 Horus on screen Error Report ...................................................................................................................................... 88 How to provide Merging Support with a Horus debug dump file ................................................................. 90 Cannot access Horus remotely in Maintenance mode for Firmware update ........................................... 91 Firewall and Antivirus ..................................................................................................................................................... 91 Symptom: Horus does not start up or will after a few minutes ..................................................................... 92

Horus User Manual

IMPORTANT SAFETY AND INSTALLATION INSTRUCTION SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS WARNING – when using electric products, basic precautions should be followed, including the following: 1. Read all of the safety and installations instructions and explanation of graphic symbols before using the product. 2. The product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance or electric current to reduce the risk of electric shock. This product is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet which is properly installed and grounded in accordance with all local codes and ordinances. DANGER – Improper connection of the equipment-grounding can result in a risk of electric shock. Do not modify the plug provided with the product – if it will not fit the outlet have a proper outlet installed by a qualified electrician. Do not use an adapter that defeats the function of the equipment-grounding conductor. If you are in doubt as to whether the product is properly grounded, check with a qualified serviceman or electrician. 3. Do not use this product near water – for example, near a bathtub, washbowl, kitchen sink, in a wet basement, or near a swimming pool, or the like. 4. This product should only be used with a stand or cart that is recommended by the manufacture. 5. This product, either alone or in combination with an amplifier and speakers or headphones, may be capable of producing sound levels that could cause permanent hearing loss. Do not operate at a high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult an audiologist. 6. The product should be located so that its location or position does not interfere with its proper ventilation. 7. The product should be located away from heat sources such as radiators, heat registers, or other products that produce heat. 8. The product should be connected to a power supply only of the type described in the operating instructions or as marked on the product. 9. The power-supply cord of the product should be unplugged from the outlet when left unused for a long period of time. When unplugging the power supply, do not pull on the cord, but grasp it by the plug. 10. Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings. 11. The product should be serviced by qualified service personnel when: A. The power supply cord or plug has been damaged. Objects have fallen, or liquid has spilled into the product, or C. The product has been exposed to rain, or D. The product does not appear to be operating normally or exhibits a

Horus User Manual

marked change in performance, or E. The product has been dropped, or the enclosure damaged. 12. Do not attempt to service the product beyond that described in the user maintenance instructions. All other servicing should be referred to qualified service personnel. 13. WARNING - Do not place objects on the power supply cord, or place the product in a position where anyone could trip over, walk on, or roll anything over cords of any type. Do not allow the product to rest on or be installed over cords of any type. Improper installations of this type create the possibility of a fire hazard and/or personal injury. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. No part of this documentation may reproduced in any form whatsoever or be stored in any data retrieval system without prior written permission of the copyright owners. This documentation is supplied on an as-is basis. Information contained within this documentation is subject to change at any time without notice and must not be relied upon. All company and product names are ™ or Registered Trademarks ® of their respective owners. Windows 7 is a trademark of Microsoft Corporation. Merging Technologies makes no warranties express or implied regarding the Horus embedded software, its quality, performance, merchantability or fitness for a particular purpose. The software is supplied “as is” you, the purchaser, are assuming the entire risk of the results of using this Merging Technologies software. In no circumstances will Merging Technologies, its owners, directors, officers, employees or agents be liable to you for any consequential, incidental or indirect loss or damages including loss of time, loss of business, loss of profits, loss of data or similar resulting from the use of or inability to use the Merging Technologies hardware and or software or for any defect in the hardware software or documentation. © Copyright Merging Technologies Inc. 2014. All rights reserved.

Horus User Manual

.               

Horus User Manual

Environmental Limits System Office Environment Parameter Limits ESD 15kV per Merging Environmental Test Specification

Horus User Manual

Declaration of Conformity According to EMC Directive 2004/108/EC Product Horus Manufacturer Merging Technologies SA Le Verney 4 CH-1070 Puidoux Switzerland Electrical Rating 90-260 VAC, 50/60 Hz, 0.2 A (at 230V) Standards EN 55103-1:2009, EN 55103-2:2009, EN 61000-3- 2 :2006+A1+A2, EN 61000-3-3 :2008 Detailed specifications of the tested and certified product are shown in the following Test Report: Test report Ref No: 16'835 Issued Date: June 2012 by Montena EMC SA The CE label is affixed on the rear of left side of the Horus unit as per below : Date 12 June 2012 Claude Cellier President Merging Technologies S.A.

Horus User Manual

Horus Warranty Information * Replacing or adding a AD, DA or MADI module and adjusting the DA module dip switch (output) is permitted under the supervision of a Merging sales partner. Any other modification will void the Horus warranty. Contacting Merging www.merging.com

Horus User Manual

HORUS BASE UNIT 75 Ω (Switchable 75 Ω Termination) = 35 Ω) Ω 75 Ω

Horus User Manual

Horus optional cards IOM-H-AD8D / AD8DP These remotely controlled Mic/Line Input cards have set a new benchmark in analog circuitry design, and provide additionally a Line level post Mic-pre “Direct Out” output. Available in models that work up to 192kHz (AD8D) and DXD/DSD256 (AD8DP) IOM-H-AD8D / AD8DP Key Features • 8 x exceptionally transparent, Swiss designed pre-amplifiers • Remote/Local switch to Line Level on a per channel basis • Completely accessible remotely for all parameter changes • Phantom Power/Phase/Low Cut switchable per channel • Removes the need for DI boxes • Allows build-in Mic splitting variants • Better than 120dB dynamic range IOM-H-AD8D / AD8DP Mic Pre-Amp + ADC Mic Pre Max Input (Pad On / Pad Off) +24 dBu / +13 dBu Input Impedance (Differential, Software Switchable Per Channel) 2 kΩ / 13.6 kΩ Input Impedance with +48V ON (Diff., Soft. Switchable Per Channel) 1.7 kΩ / 6.8 kΩ Dynamic Range (A-weighted, typ.) , ref +10 dBu 127 dB Gain Range (software controlled) 0 dB to +66 dB Gain Step/Precision 0.5 dB / ±0.2 dB THD+N Pre + A/D (20 Hz-20 kHz) @ -2 dBFS (AD8/AD8P) < -96dB (0.0016 %) / -100 dB (0.001 %) Interchannel Crosstalk @ 1kHz, typ. < -125 dB EIN @ >40 dB Gain (150Ω Source Impedance, A-weighted, typ.) < -128 dBu Common Mode Rejection Rate (20 Hz – 20 kHz) > 60 dB (up to 0 dBFS) Phantom Power (Software Switchable Per Channel) +48V Phase Reverse (Software Switchable Per Channel) YES Low Cut filter (Software Switchable Per Channel) -12 dB/octave, 80 Hz Line Input Max Line Input for 0 dBFS +24 dBu Input Impedance (Differential) 13.6 kΩ Dynamic Range (A-weighted, typ), ref +24 dBu 120 dB THD+N Line+A/D (20 Hz - 20 kHz) @ -12 dBFS < -100 dB (0.001%) Interchannel Crosstalk @ 1kHz @ fullscale < -120 dB Sensitivity Range for 0 dBFS (software controlled) -42 dBu to +24 dBu Gain Step/Precision 0.5 dB / ±0.2 dB Common Mode Rejection Rate (20 Hz – 20 kHz) > 60 dB (up to 0 dBFS) Connector Pinout DB-25 / AES59 (Tascam Ana.)

Horus User Manual

IOM-H-AD8D/AD8DP Mic-Pre Analog Section Frequency response +0/-0.5 dB, Line 5 Hz - 75 kHz Frequency response +0/-2.0 dB, Line 2.5 Hz - 150 kHz Frequency response +0/-0.5 dB, Mic 10 Hz - 100 kHz Frequency response +0/-2.0 dB, Mic 5 Hz - 200 kHz THD+N (1 kHz), Line/Mic at G=0dB <-115 dB (0.00018 %) THD+N (20 Hz-20 kHz) , Line/Mic at G=0dB <-112 dB (0.00025 %) Interchannel Crosstalk @ 1kHz, typ. -135dB 5° low-end in-channel Ø deviation pt: Line 13 Hz 5° low-end in-channel Ø deviation pt: Mic 35 Hz Interchannel phase 10 Hz - 100 kHz < ±0.1° IOM-H-AD8D/AD8DP Direct Out Section Frequency response +0/-0.3dB @ Gain 40dB 10 Hz –50kHz Max Direct Output level typ. +24 dBu Output Impedance (Differential) < 100 Ω Dynamic Range (A-weighted, typ) 133 dB THD+N (1 kHz) @ +10dBu < -120dB (0.0001 %) Input Connector Pinout DB-25 / AES59 (Tascam Ana.) Direct Output Connector Pinout DB-25 / AES59 (Tascam Ana.) Gain behavior of the Direct Out section As the Direct Out output is taken just after the Mic-pre analog section, the gain adjustments are not as smooth and linear as after the digital conversion. The figure below shows the behaviour of the gain on the Direct Out (in blue) compared to the gain on the digital side (in red). Note: on the Direct Out the maximum available gain is + 40.1 dB.

Horus User Manual

Mic / Line pad -11dB 48V phantom power On / Off Preamp analog gain 0 to + 40dB AD8D / AD8DP run 1 to run 8 A/D converter Analog input Digital gain Direct Out +18dBu Analog output Preamp analog gain 0 to + 40dB 48V phantom power On / Off Mic / Line pad -11dB AD8D / AD8DP run 9 and above A/D converter Analog input Digital gain Direct Out +13/+24dBu Analog output Zin selector 2kΩ / 6.8kΩ / 13kΩ 2kΩ: dynamic mic (no phantom) 6.8kΩ: condenser mic (with phantom ON) 13.6kΩ: line input

Horus User Manual

IOM-HORUS-DA8/DA8P The DA8 (up to 192kHz) and the DA8P (up to DSD) have been shown in testing to be consistently the quietest multichannel D/A conversion modules available anywhere. IOM-HORUS-DA8/DA8P Key Features • Auto-mute circuitry for “no-pop” power cycling • Digitally controlled trims for line up procedures • Dynamic range of 127dB (typ.) • Easy to set dip switches for international operating levels IOM-HORUS-DA8/DA8P Specifications Max Line Output @ 0 dBFS (jumpers on +24 dBu) +24 dBu +0/-0.5 dB Frequency response +0/-0.3dB @ fs = 48000 Hz 6 Hz – 20 kHz Frequency response +0/-0.3dB @ fs = 2.8224 MHz (DSD) NA / 6 Hz – 20 kHz Frequency response +0/-3.0dB @ fs = 2.8224 MHz (DSD) NA / 2 Hz – 50 kHz Line Output Impedance (Differential) 100 Ω Dynamic Range (A-weighted, typ) 126 dB THD+N D/A (1 kHz) @ 0 dBFS (IOM-HORUS-DA8) < -113dB (0.00022 %) THD+N D/A (1 kHz) @ 0 dBFS (IOM-HORUS-DA8P) < -115dB (0.00018 %) Interchannel Crosstalk @ 1kHz, typ. -135 dB Connector Pinout DB-25 / AES59 (Tascam Ana.)

Horus User Manual

Line Output Level calibration The DA8 and DA8P modules feature both hardware level settings and a software fine adjustment to align the Analog Output levels to whatever local/organization operational levels are mandated. On DA8/DA8P cards from run 7 upwards, the hardware level setting is done via software through the option “max output level” in each DA’s setting page, allowing either + 24 dBu or 18 dBu max level. On DA8/DA8P cards prior to run 7 the hardware level setting is in the form of 4 DIP switches per output channel The Hardware settings will usually be set only once, at product installation, and only if the desired Operating Line Level differs from the default ex-factory settings of +18 dBu for 0 dBFS. Procedure for Hardware alignment (for DA8 prior to run 7): Output Level (dBu) +24 +18 +15 +12 Switch S1 to S8 1 ON ON 2 ON ON 3 ON ON 4 ON ON

Horus User Manual

D/A converter Analog Output Level Selection +12dB/+15dB/ +18dB/+24dB DA8 / DA8P run 1 to run 6 Digital input Mute Relay DA8 / DA8P run 7 and above Analog Output D/A converter Analog Output Level Selection +18dB/+24dB Mute Switch Analog Output Digital input Roll Off Filter Digital Output Attenuation [0 .. -60dB] Roll Off Filter Digital Output Attenuation [0 .. -60dB]

Horus User Manual

IOM-H-ADA8 These remotely controlled Mic/Line Input and Output cards have broken a new barrier in terms of compactness as well as ultra-low power consumption without compromising on the audio quality. These cards work at sampling rates up to 192 kHz Using those combined 8 channel Mic/Line In and Line Out cards allow the Hapi to be configured with up to 16 channels of Analog In/Out. IOM-H-ADA8 Key Features • 8 x exceptionally transparent, Swiss designed pre-amplifiers • Remote/Local switch to Line Level on a per channel basis • Completely accessible remotely for all parameter changes • Phantom Power/Phase/Low Cut/Impedance switchable per channel • Dynamic range of 120dB (A-weighted, typ) on the Line inputs • Auto-mute circuitry for “no-pop” power cycling • Digitally controlled output trims for line up procedures • Dynamic range of 123dB (A-weighted, typ.) on the Line outputs IOM-H-ADA8 Specifications IOM-H-ADA8 Mic-Pre + ADC Section Mic Pre Max Input (Pad On / Pad Off) +24 dBu / +13 dBu Input Impedance (Differential, Software Switchable Per Channel) 2 kΩ / 13.6 kΩ Input Impedance with +48V ON (Diff., Soft. Switchable Per Channel) 1.7 kΩ / 6.8 kΩ Frequency response +0/-0.3dB @ fs = 48 kHz 10 Hz – 22 kHz Frequency response +0/-0.3dB @ fs = 96 kHz 10 Hz – 44 kHz Frequency response +0/-0.3dB @ fs = 192 kHz 10 Hz – 85 kHz Dynamic Range (A-weighted, typ.), ref +13 dBu 119.5 dB Gain Range (software controlled) 0 dB to +66 dB Gain Step/Precision 0.5 dB / ±0.2 dB THD+N Pre + A/D (20 Hz - 20 kHz) @ -2 dBFS < -102 dB (0.0008 %) Interchannel Crosstalk @ 1kHz < -125 dB EIN @ >40 dB Gain (150Ω Source Impedance, A-weighted) < -128 dBu Common Mode Rejection Rate (20 Hz – 20 kHz) > 60 dB (up to 0 dBFS) Phantom Power (Software Switchable Per Channel) +48V Phase Reverse (Software Switchable Per Channel) YES Low Cut filter (Software Switchable Per Channel) -12 dB/octave, 80 Hz IOM-H-ADA8 Line input Section Max Line Input for 0 dBFS +24 dBu Input Impedance (Differential) 13.6 kΩ Dynamic Range (A-weighted, typ.), ref +24 dBu 120 dB THD+N Line+A/D (20 Hz - 20 kHz) @ -2 dBFS < -102 dB (0.0008%) Interchannel Crosstalk @ 1kHz < -125 dB Sensitivity Range for 0 dBFS (software controlled) -42 dBu to +24 dBu Gain Step/Precision 0.5 dB / ±0.2 dB Common Mode Rejection Rate (20 Hz – 20 kHz) > 60 dB (up to 0 dBFS) Connector Pinout DB-25 / AES59 (Tascam Ana.)

Horus User Manual

IOM-H-ADA8 Mic-Pre Analog Section Frequency response +0/-0.5 dB, Line 5 Hz - 75 kHz Frequency response +0/-2.0 dB, Line 2.5 Hz - 150 kHz Frequency response +0/-0.5 dB, Mic 10 Hz - 100 kHz Frequency response +0/-2.0 dB, Mic 5 Hz - 200 kHz THD+N (1 kHz), Line/Mic at G=0dB <-115 dB (0.00018 %) THD+N (20 Hz-20 kHz) , Line/Mic at G=0dB <-112 dB (0.00025 %) Interchannel Crosstalk @ 1kHz, typ. -135dB 5° low-end in-channel Ø deviation pt: Line 13 Hz 5° low-end in-channel Ø deviation pt: Mic 35 Hz Interchannel phase 10 Hz - 100 kHz < ±0.1° IOM-H- ADA8 Line Out Section Max Output level software switchable for 0 dBFS +24 dBu / +18 dBu +0/-0.5 dB Frequency response +0/-0.3dB @ fs = 48 kHz 6 Hz – 22 kHz Frequency response +0/-3dB @ fs = 96 kHz 6 Hz – 44 kHz Frequency response +0/-3dB @ fs = 192 kHz 6 Hz – 88 kHz Output Impedance (Differential) < 100 Ω Dynamic Range (A-weighted, typ.) 123 dB THD+N (1 kHz) @ 0dBFS < -108 dB (0.0004 %) Interchannel Crosstalk @ 1kHz < -135 dB Connector Pinout DB-25 / AES59 (Tascam Ana.) IOM-H-ADA8 block diagram Zin selector 2kΩ / 6.8kΩ / 13kΩ 48V phantom power On / Off Preamp analog gain 0 to + 40dB Mic / Line pad -15dB Analog input A/D converter Digital gain 2kΩ: dynamic mic (no phantom) 6.8kΩ: condenser mic (with phantom ON) 13.6kΩ: line input D/A converter Analog Output Level Selection +18dB/+24dB Mute Switch Analog Output Digital input Roll Off Filter Digital Output Attenuation [0 .. -60dB] MIC / LINE IN LINE OUT

Horus User Manual

IOM-H-PT64 This module allows you to connect your Horus directly to a Pro Tools HD or Pro Tools HDX system through its two Digilink Mini connectors. You can insert up to two modules in a device, meaning you can manage up to 128 Channels at a time. Note that, in Horus, the cards can only be mounted in Slot 3 and Slot 6. Requires Firmware 3.0.5b28137 and above IOM-H-PT64 Key Features • Up to 64 Channels @48kHz per module (32 ch. @ 96kHz, 16 ch. @192kHz) • Up to two IOM-H-PT64 modules in one Horus/Hapi • Automatic Delay Compensation • Three hardware emulation modes (Digidesign 192I/O, HDIO and HDMADI) • Two Digilink mini connectors Ports usage There are two connectors on the IOM-H-PT64 module called Port 1 and Port 2. Working at 44.1/48kHz, both Ports are enabled. Channels I/O 1-32 are carried through Port 1 and channels I/O 33-64 through Port 2. If only 32 channels are needed, it is possible to use only Port 1 or Port 2. With a Sample Rate of 88.2/96kHz, only Port 1 is enabled. All 32 I/O channels will be carried through this Port. If the Sample Rate is set to 176.4/192kHz, then all 16 I/O channels will be carried through Port 1 as well. If both Ports are connected, Port 1 of your IOM-H-PT64 should be connected to Port 1 on the AVID interface and Port 2 should be connected to Port 2. Synchronization and Word Clock When properly configured, a Horus is able to automatically change its internal clock to match a Pro Tools project’s Sample Rate. The proper IOM-H-PT64 module must be selected in the I/O & Sync menu (PT 3 or PT 6 if module is in Slot 3 or 6). The Auto-follow option must be enabled in Setup -> Format menu, and Horus will change its Internal Sample Rate automatically.

Horus User Manual

In Pro Tools, the Clock source should be set to Internal for the device emulated by the IOM-H-PT64 module (HD MADI in the following example).

Horus User Manual

Setups with multiple devices Here are a few setups using several Pro Tools Hardware interfaces that need to be synchronized. The other devices present in the setup can be synchronized in several different ways. If two Horus interfaces are used in a setup, they can be synchronized through the Word Clock connectors. To send the actual Sample Rate, the Follow SR option in Setup -> Format must be enabled. IOM-H-PT64 HD Card 1 Pro Tools HD/HDX Clock Source : Horus 1 Internal Sync Source: IOM-H-PT64 WCK Out WCK In Sync Source: WCK IOM-H-PT64 HD Card 2 Horus 1 Horus 2 The next setup is using Horus as the Master clock for all devices. In this case, the Clock Source must be set to the other device’s Word Clock. The Follow SR option in Setup -> Format must be enabled. IOM-H-PT64 HD Card 1 Pro Tools HD/HDX Clock Source : Other device’s WClk In HD Card 2 Sync Source: IOM-H-PT64 WCK Out Additionnal HDLink capable interfaces Horus 1 In the following setup, an external Master Clock is used for all devices. In this case, the external Master Clock controls the Horus Sample Rate. Hence, the external Master Clock must be set accordingly to the Pro Tools project Sample Rate. IOM-H-PT64 HD Card 1 Pro Tools HD/HDX Clock Source : External Master Clock HD Card 2 Sync Source: WCK External Master Clock WCK In WCK Out Additionnal HDLink capable interfaces Horus 1

Horus User Manual

IOM-H-PT64 block diagram Output Delay Decoder From Pro Tools Input Delay Encoder To Pro Tools To Horus From Horus Delay compensation Input and Output delay are strongly dependent on the Hardware. This implies that if one records a single source with two different devices at the same time, one will get two slightly out-of-phase tracks. This is explained by the fact that every device has its own circuitry and different components. To minimize this issue, Pro Tools implemented an Auto Delay Compensation feature which will automatically shift the recording depending on the Hardware used. The IOM-H-PT64 module was made to emulate three different Digidesign interfaces and match every interface’s actual input/output latency (within a margin of maximum 3 samples). This chart shows what latency to expect for different setups. Analog/Digital modules latencies are already included in these measures. Emulation Mode Routing 44k1/48k 88k2/96k 176k4/192k None Input - 2* smpl. 2* smpl. 2* smpl. Output - 2* smpl. 2* smpl. 2* smpl. 192IO Input From AD8D 65 smpl. 65 smpl. 65 smpl. Output To DA8 24 smpl. 14 smpl. 15 smpl. HDIO Input From AD8D 16 smpl. 12 smpl. 11 smpl. Output To DA8 56 smpl. 21 smpl. 21 smpl. HD MADI Input From MADI 6 smpl. 6 smpl. 7 smpl. Output To MADI 5 smpl. 5 smpl. 7 smpl. * Added to the Input/Output latencies of the modules used For the delay compensation to be working, it must be enabled in the ProTools software (Options -> Delay Compensation). Emulation Mode Configures which Digidesign interface the IOM-H-PT64 module will emulate in Pro Tools. This option does not affect the Horus routing or preamps, it will just set the Input/Output Delays as seen above. When set to None, Pro Tools will see the module as an HD MADI, but Horus will use the minimum latency. Therefore, Delay Compensation will not be accurate on Pro Tools in this mode. Error AAE -6116 When Horus is configured to follow the Sample Rate asked by Pro Tools, an AAE -6116 error might happen when opening a project with a new Sample Rate. If it happens, click OK to close the error information. Then, when trying to play the file, the error might show again. After clicking OK, the error should not appear again. If this issue is too frequent, a way to avoid it is to disable the Auto-Follow option in Setup -> Formats and change the Sample Rate on Horus by hand. This should reduce the probability of getting such an error.

Horus User Manual

Horus cables Connecting the analog audio Input cables to the AD8/AD8P modules

Horus User Manual

Connecting the MADI cable Connecting the Wordclock input/output Connecting the Sync Cable

Horus User Manual

MIDI connection: Connecting the RAVENNA Ethernet cables

Horus User Manual

Horus key features Modular analog interfacing Modular Device connectivity AD8 / AD8P Remote controlled Mic/Line A/D module DA8 / DA8P Safety Conscious Analogue Line output Modules ADA8 Remote controlled Mic/Line A/D module with transparent Analog output The ADA8 work at sample rates up to 192 kHz. HD Link with Pro Tools HD The PT Module allows the Horus to communicate with a Pro Tools HD card. With two modules in one interface, up to 128 channels can be recorded simultaneously. Redundant power supply options Redundant versus secondary Power supply (More than 3 Analog Input modules)

Horus User Manual

MADI 1 MADI 2 (Expansion Slot) AES-EBU Signal routing paradigm RAVENNA IP Audio Synchronization Audio is not the only information that can pass down the RAVENNA connection. Horus is also able to send sync (LTC) down the same wire to and from the Hapi unit. For more details refer to the RAVENNA network guide available on www.merging.com Key Specifications

Horus User Manual

Horus Modules Capabilities Modules AD8 AD8D standard AD8P AD8DP premium DA8 standard DA8P premium ADA8 PT64 Headphone MADI AES Sampling Rates 44.1/48kHz √ √ √ √ √ √ (64 I/O) √ √ (64 I/O) √ 88.2/96kHz √ √ √ √ √ √ (32 I/O) √ √ (32 I/O) √ 176.4/192kHz √ √ √ √ √ √ (16 I/O) √ √ (16 I/O) √ DXD/384kHz √ √ √ √ (8 I/O) DSD64 √ √ √ * DSD128 √ √ √ * DSD256 √ √ Horus Modules Latencies Modules AD standard premium DA standard premium ADA8 Input Output PT64 Headphone MADI AES Sampling Rates 44.1/48kHz 15 smpl. 12 smpl. * 16 smpl. 9 smpl. ** 2 smpl. 15 smpl. 3 smpl. 3 smpl. 88.2/96kHz 10 smpl. 12 smpl. * 16 smpl. 9 smpl. ** 2 smpl. 8 smpl. 3 smpl. 3 smpl. 176.4/192kHz 8 smpl. 12 smpl. * 13 smpl. 9 smpl. ** 2 smpl. 8 smpl. 3 smpl. 3 smpl. DXD/384kHz 8 smpl. 12 smpl. * NA NA NA 8 smpl. 3 smpl. NA * DA Filter setting - Slow Roll Off Filter option = 12 Samples - Sharp Roll Off Filter option = 39 Samples (More details available under the DA Module chapter below) ** ADA Filter setting - Slow Roll Off Filter option = 9 Samples - Sharp Roll Off Filter option = 38 Samples

Horus User Manual

Installing an additional Horus MADI Extension Module (MADM or MADS)

Horus User Manual

Installing the Merging PCIe Ethernet Controller Card NET-MSC-GBEX1

Horus User Manual

Horus recommended placement in Rack Horus power ON Connecting the Power Cable

Horus User Manual

Horus touch screen control interface Horus Menu Hierarchy

Horus User Manual

Meters Menu LED indications: Meters Settings Menu

Horus User Manual

Line Fader of 0 dB, means 0 dBFS for +24 dBu Analog signal level present at the Line input Line Fader of + 6 dB, means 0 dBFS for +18 dBu Analog signal level present at the Line input Line Fader of + 20 dB, means 0 dBFS for +4 dBu Analog signal level present at the Line input Line Fader of + 66 dB, means 0 dBFS for -42 dBu Analog signal level present at the Line input

Horus User Manual

Zlo – Zhi Mic input impedance (only available for ADA8 & AD8D/AD8DP run 9 and above modules) 48V Phantom Disabled Enabled Zlo 2 kΩ 1.7 kΩ Zhi 13.6 kΩ 6.8 kΩ

Horus User Manual

Formats Menu (Setup) Horus can be configured in DXD/DSD and in this mode the Horus can receive any audio data format stream and can generate DXD or DSD(64, 128 or 256) stream depending on the A/D audio data format chosen.

Horus User Manual

Routing: Configuration Headphone - D/A - AES - MADI - PT Routing Output Source (similar) ADA N The ADA buttons, which become active if you have 1 or more ADA8 modules installed in the Hapi unit, give access to the Input controls. Loopback: Should only be used for test purposes.

Horus User Manual

Modules Menu (Setup) Headphone A/D N ADA N The ADA buttons, which become active if you have 1 or more ADA8 modules installed in the Hapi unit, give access to the Input controls. D/A N PT 3/6 MADI 1-2 AES 1-3 TimeCode

Horus User Manual

Modules: AES Sub-Menu Output Source: Shortcut to the Output Source Routing Page configuration Modules: A/D Sub-Menu Example: Setting a gain alignment of +10dB will make the Horus, Web Access or the Pyramix PreAmps control to be offset by a scaling of +10 dB. Module

Horus User Manual

Modules: ADA Sub-Menu Mic Alignment: User can offset the Mic Gain Alignment scaling from a Range of 0dB to +12dB. Example: Setting a gain alignment of +10dB will make the Hapi, Web Access or the Pyramix PreAmps control to be offset by a scaling of +10 dB. Max Level Maximum Output Level: +18 dBu or +24 dBu Output attenuation: Calibration of the D/A output (Range -60.0 dB to 0 dB). Refer to the Hardware section for the D/A onboard output level calibration. Roll Off Filter: Sharp roll-off filter: Offers a flat frequency response up to 22kHz, within 0.2dB, which has the tradeoff of 36 samples latency. This mode was and still is the default one. Slow roll-off filter: Offers a low latency of 9 samples, with the tradeoff of a gentle frequency response attenuation starting around 16kHz and reaching - 2.5dB at 22kHz Serial Number: This is the place you can access all your Modules serial numbers without having to unslot them or open the box Type: Module Type description

Horus User Manual

Modules: PT Sub-Menu Emulation mode: Selection of the Hardware emulated in Pro Tools. Latency is adapted to the mode chosen, see detailed table in IOM-H-PT64 section. None mode is seen as an HD MADI in Pro Tools, but has the lowest latency. Serial Number: Module Serial Number and Run Output Source: Selection of the output source sent to Pro Tools for each of the 8 groups. Any of the digital or analog inputs can be routed to Pro Tools as well as RAVENNA signals. Here is an example of routing: PT 3 (1-8): Routed on PT 3 (1-8) PT 3 (9-16): Routed on PT 3 (9-16) PT 3 (17-24): Routed on A/D 5 (1-8) PT 3 (25-32): Routed on AES 1 (1-8) PT 3 (33-40): Routed on AES 2 (1-8) PT 3 (41-48): Routed on MADI 1 (1-8) PT 3 (49-56): Routed on MADI 1 (9-16) PT 3 (57-64): Routed on RAVENNA

Horus User Manual

Modules: Loopback (hidden menu, available only for debug use) Transparency Check: This is a Debug Utility tool that verifies the bit transparency of the audio path

Horus User Manual

Presets Menu (Setup) can be loaded (one at a time) Auto Save: If enabled the save configuration will happen at every 2 minutes.

Horus User Manual

System (Setup): The Dark option will display a black Screen Saver, mainly used when Horus needs to be a discreet stage box. Terminations: 75Ω for WCK: Sets 75Ω termination for the Wordclock Input. 75Ω for Video: Sets 75Ω termination for the Video reference Input. Unless the Video Reference signal provided to the Horus is daisy-chained to other equipment, you should always terminate your Video signal for most reliable operation.

Horus User Manual

Horus Web Control access Installing and accessing the Horus Control interface remotely http://www.merging.com/products/horus/downloads - - -

Horus User Manual

For other parameters, please refer to the PreAmps module description (above)

Horus User Manual

How to use the IOM-H-PT64 module with Digidesign HDIO            o o

Horus User Manual

Manage Mic PREs from Pro Tools MAC All details are available in the MergingVirtual Audio Device (formerly Core Audio Driver) Guide: http://www.merging.com/products/networked-audio/downloads

Horus User Manual

Pro Tools on PC Horus / Hapi http://www.tobias-erichsen.de/wp-content/uploads/2012/08/rtpMIDI_1_0_11_227.zip

Horus User Manual

Horus Firmware update procedure http://www.merging.com/products/horus/downloads

Horus User Manual

http://www.merging.com/products/horus/downloads http://www.merging.com/products/horus/downloadshttp://www.merging.com/horus/download

Horus User Manual

10) Wrong maintenance version, must be >= 31” . Note: A Maintenance Mode update requires a shutdown of the Horus once the update completed.

Horus User Manual

Wrong maintenance version, must be >= 31”. This means that you must first install the latest Maintenance Firmware prior to updating to the latest Firmware Contact us at [email protected] if your firmware update cannot be executed

Horus User Manual

Horus troubleshooting Horus on screen Error Report "Primary Power Supply Failure"; "Secondary Power Supply Failure"; "Two Power Supplies Required" in case of more than 3 A/D are present "Temperature too high"; "Horus Application failure, please reboot" "Fan failure" "Ethernet input: GP fifo overrun"; "Ethernet input: GP descriptors fifo overrun";

Horus User Manual

"Ethernet input: Audio packet still pending"; "Ethernet input: Audio pipeline too small"; "Ethernet input: Wrong sequence number"; "Ethernet input: CRC error"; "Ethernet input: Queue mux error"; "Ethernet input: Audio buffer too small"; "Ethernet input: SSRC mismatch" "Ethernet input: Unknown error"; "FPGA memory: Timeout"; "FPGA memory: Unknown error"; “48V power failure: all A/D 48V forced off until next reboot”

Horus User Manual

How to provide Merging Support with a Horus debug dump file [email protected]

Horus User Manual

Cannot access Horus remotely in Maintenance mode for Firmware update Firewall and Antivirus

Horus User Manual

Symptom: Horus does not start up or will after a few minutes