4. Refrigerating Cycle Diagram

Indoor Unit Outdoor Unit T1 T2 2-Way valve 3-Way valve Gas side Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Liquid side Capillary tube 4-Way valve Cooling Heating Gas leak check point Compressor Cross fan Propeller fan ...

The input voltage should be rating voltage ±10% range.

The airconditioner may not operate properly if the voltage is out of this range. 2. Is the link cable linking the indoor unit and the outdoor unit linked properly? The indoor unit and the outdoor unit shall be linked by 5 cables. Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables. Otherwise the airconditioner may not operate properly. 3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of t ...

Exploded Views and Parts List

I AQ(T)12P4G✳ /SH12ZP4✳ : DB93-02541A(Ionizer) I AQ(T)12P4G✳ /SH12ZP4✳ : DB93-02541B(Titanium Filter) ...

6-2-4 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)

1. Checklist : 1) Is the indoor unit fan motor properly connected with the connector (CN72)? 2) Is the AC voltage correct? 3) Is HALL IC in indoor fan motor properly connected with the connector (CN44)? 4) Is the running capacitor (CR71) properly connected with PCB board? 2. Troubleshooting procedure After unplugging out the power cord should be reconnected within 5 seconds. Does the OPERATION lamp blink? Does the Solid State Relay(SS71) work properly? Is the supply voltage of the fan mo ...

Energy Efficiency Ratio

Heating BTU/W.h SASO Power V-Hz Cooling Power Consumption Heating W SASO Cooling Operating Current Heating A SASO Cooling Power Factor Heating % SASO Starting Current A Length m Power Cord Number of Core Wire Capacity A Outer Dimension W x H x D mm inch Weight kg Refrigerant Pipe Liquid mm x L(m) GAS mm x L(m) Drain Hose D x L(mm) Type Compressor Motor Type Rated Output Type Blower Motor Type Rated ...

6-2-8 When the remote control is not receiving

1. Check if the connector was normally assembled. 2. Put the set in operation and check the voltage of No. 3(+) and No. 2(-) of the main PCB CN91 while operating the remote control. When the voltage descends below 3V, the assembly module PCB is normal and the main PCB is poor. Then replace the main PCB. 3. Replace the assembly display PCB because the module PCB is poor if the voltage between No. 2~3 of CN91 maintains 5V after the remote control starts operation. ...

Samsung SH07ZP2 Series user guide recommended for: AW18P1HBC, AW0593L, AVMDH, BD-C5900, AR-KP/JP Series.

⚠️ Download Safety

The Air Conditioner Service manual (54 pages) is completely safe to download (last scan date: 12/11/2025).

Related PDF Instructions for Samsung SH07ZP2 Series:

Air Conditioner Equipment: Frequently Requested

Have some Questions about Samsung SH07ZP2 Series Device?

Get valuable and actionable advices from other Samsung SH07ZP2 Series device users. Describe your problem or question, regarding the using of SH07ZP2 Series, in as much detail as possible, and other users will be able to answer you.