Text of the manual

Doc. No.: 255-700-166

PacketStar® PSAX 6-Port DS1 IMA Module User Guide for PacketStar® PSAX Multiservice Media Gateways Issue 1, August 2001 System Software Release 7.0 AQueView® EMS Software Release 5.0

Copyright © 2001 by Lucent Technologies. All rights reserved.

For trademark, regulatory compliance, and related legal information, see the "Copyright and Legal Notices" section.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Copyright and Legal Notices Copyright Copyright © 2001 by Lucent Technologies. All rights reserved. This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the originating organization and the business management owner of the material. This document was prepared by the Information Design and Development Team of Lucent Technologies, PacketStar ® PSAX Products. Offices are located in Landover, Maryland, USA. Trademarks 7R/E, APX-8000, CellPipe, ConnectReach, ConnectStar, and STINGER are trademarks; and PacketStar, AQueView, Lucent Technologies, and the Lucent Technologies logo are registered trademarks of Lucent Technologies in the USA. Other product and brand names mentioned in this guide are trademarks or registered trademarks of their respective owners. Warranty Information Software and Hardware Limited Warranties Lucent Technologies provides a 90-day limited software warranty, and a one- year limited hardware warranty on this product. Refer to the Software License and Limited Warranty Agreement and the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your package for more information. Every effort has been made to ensure that this document is complete and accurate at the time of release, but information is subject to change. Lucent Technologies assumes no responsibility or liability for errors or inaccuracies that may appear in this guide.

Copyright and Legal Notices

Regulatory Standards Compliance iv 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Warranty Warnings ! CAUTION: Modifying or tampering with PSAX chassis components may void your warranty. Any modification to this equipment not expressly authorized by Lucent Technologies may void your granted authority to operate such equipment. ! CAUTION: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the Multiservice Media Gateway system from indicating any erroneous failure messages, and allows the Multiservice Media Gateway system to reinitialize and display the accurate configuration of the module that is inserted. ! CAUTION: Shipping the chassis with removable modules installed may cause damage to the chassis and the modules. Damage to any of the components in the system resulting from shipping the chassis with removable modules installed could void your warranty. Only Lucent- authorized personnel should ship the Multiservice Media Gateway chassis with a module installed. Regulatory Standards Compliance Safety and Electromagnetic Compatibility (EMC) The 6-Port DS1 IMA module (model 23N33) is compliant with applicable safety and EMC standards when configured with the following PacketStar® PSAX systems: • PSAX 20 base system, 110 V ac (models 02S00 and 02S01) • PSAX AC 60 base systems: ~ PSAX AC 60 system, 110 V ac (models 50S01 and 51S01) ~ PSAX AC 60 system, 220 V ac (models 50S02 and 51S02) ~ PSAX AC 60 system, -48 V dc (models 50S48 and 51S48) • PSAX 1000 chassis (model 10S00) • PSAX 1250 chassis (models 20S00 and 20S10) • PSAX 2300 chassis (model 23S00) • PSAX 4500 chassis (model 45S00)

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Copyright and Legal Notices Regulatory Statements Please refer to the appropriate PacketStar® PSAX Multiservice Media Gateway user guide or installation guide for additional information. Telecommunications • FCC Part 68 (USA) • CS-03 Issue 8 (Canada) • JATE (Japan) Regulatory Statements USA Regulatory Statements FCC Part 68 This equipment complies with Part 68 of the FCC rules. On the back of the PSAX chassis is a label that contains the FCC registration number, in addition to other information. You must provide this information to the telephone company, if they request it. The FCC requires Lucent Technologies to provide you with the following information: 1. This equipment has digital service interface capabilities using RJ-48C and RJ-48H connectors. The facility interface codes with which this equipment complies for digital services are as follows: 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. This equipment has loop start interface capabilities using an RJ-11C connector. The facility interface code with which this equipment complies for service is 02LS2. The service order codes for this equipment are 6.0F for the T-1 interface and 9.0Y for the loop start interface. 2. An FCC-compliant telephone network interface jack is built into this equipment and is compatible with interconnections that are Part 68 compliant. 3. The REN for the Voice 2-Wire Office module when used in this equipment is 0.7B. 4. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service might be required. But if advance notice is not practical, the telephone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe this is necessary. 5. The telephone company might make changes in its facilities, equipment, operations, or procedures that could affect the operation of this equipment. If this happens, the telephone company will provide advance notice for you to make necessary modifications to maintain uninterrupted service.

Copyright and Legal Notices

Regulatory Statements vi 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 6. If you experience trouble with this equipment, or need repairs or warranty information, please refer to the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your PSAX product shipment for instructions on obtaining technical support in your area. If this equipment is causing harm to the telephone network, the telephone company might request that you disconnect the equipment until the problem is resolved. 7. This equipment has no user-serviceable parts. This equipment cannot be used on public coin telephone service provided by the telephone company. Connection to party line service is subject to state tariffs. Contact your state public utility commission, public service commission, or corporation commission for information. Canadian Regulatory Statements CS-03 Issue 8 The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee that the equipment will operate to the user’s satisfaction. Before installing this equipment, the user should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed by using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single-line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment or equipment malfunctions might give the telecommunications company cause to request the user to disconnect the equipment. For their own protection, users should ensure that the ground connections of the power utility, telephone lines, and internal metallic water pipe system are connected together. This precaution may be particularly important in rural areas. ! CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority or electrician. The Ringer Equivalence Number (REN) assigned to the Voice 2-Wire Office module denotes the percentage of the total load to be connected to a telephone loop, which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the REN of all devices does not exceed 5.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Copyright and Legal Notices Regulatory Statements The REN for the Voice 2-Wire Office module when used in the PSAX system is 0.7B. SH-03 Version 8 Le label Industrie Canada permet de reconnaître les équipements homologués. Cette homologation indique que l’équipement satisfait certaines règles de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le ministère de l’Industrie ne garantit pas que l’équipement fonctionnera à la satisfaction de l’utilisateur. Avant d’installer cet équipement, l’utilisateur doit s’assurer qu’il est permis de le connecter aux installations de la compagnie de télécommunications locale. L’équipement doit également être connecté suivant une méthode convenable. Dans certains cas, il sera nécessaire de prolonger le câblage intérieur de la ligne d’abonné de la compagnie au moyen d’un connecteur homologué (rallonge de téléphone). L’abonné doit savoir que, dans certaines situations, la conformité aux dispositions ci-dessus ne prévient pas nécessairement la dégradation du service. La réparation de certains équipements homologués doit être assurée par un atelier agréé désigné par le fournisseur. Toute réparation ou altération effectuée par l’utilisateur ou tout mauvais fonctionnement de cet équipement peut donner à la compagnie de téléphone des raisons de demander audit utilisateur de déconnecter celui-ci. Pour leur propre sécurité, les utilisateurs doivent veiller à ce que les mises à la terre de l’alimentation secteur, des lignes téléphoniques et du système intérieur de conduites d’eau métalliques soient raccordés ensemble. Cette précaution peut s’avérer particulièrement importante dans les zones rurales. ! CAUTION: Les utilisateurs ne doivent pas tenter d’effectuer eux-mêmes ces raccordements, mais doivent prendre contact avec un électricien ou organisme de vérification compétent. Le nombre équivalent de sonnerie (REN) attribué au module central bifilaire (Voice 2-Wire Office) correspond au pourcentage de la charge totale à connecter à un circuit téléphonique bifilaire; il est utilisé par l’appareil pour prévenir la surcharge. Le circuit peut être terminé par n’importe quelle combinaison d’appareils, à la seule condition que le total des REN de ces derniers ne dépasse pas cinq. Lorsqu’il est utilisé dans le système PSAX, le module central bifilaire possède un REN de 0,7 B. Japanese Regulatory Statements JATE This module complies with the Japan Approvals Institute for Telecommunication Equipment (JATE) requirements. The approval number for the 6-Port DS1 IMA module is D00-0807JP.

Copyright and Legal Notices

Regulatory Statements viii 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 The marking for the 6-Port DS1 IMA module is as follows: T D00-0807

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Safety Warnings and Information When installing and operating the PacketStar® PSAX Multiservice Media Gateway, follow the safety guidelines provided below to help prevent serious personal injury and damage to the Multiservice Media Gateway equipment. Please read all warnings and instructions supplied before beginning installation or configuration of the Multiservice Media Gateway equipment. In addition to the general safety information provided below, you should also refer to the text in the user and installation guides for other important safety information and procedures. ! DANGER: Read all installation instructions before connecting the system to a power source. WARNING: ! Be sure to use the ejector handles during installation and removal of I/O and server modules. WARNING: ! Electrostatic discharge (ESD) can damage module and chassis components. All personnel should be grounded and follow proper ESD procedures before installing, removing, or handling hardware components. ! CAUTION: Ultimate disposal of this product should be handled according to all laws and regulations in your specific geographic region. ! CAUTION: Do not make electrical or mechanical modifications to any of the components in the PSAX system. Lucent Technologies is not responsible for the safety or the performance of a modified Lucent product. Do not attempt to repair any failed Power Supply module, Stratum 3–4 module, CPU module, I/O, or server module.

Safety Warnings and Information

x 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Contents Copyright and Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Copyright. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Software and Hardware Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Warranty Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Safety and Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Telecommunications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v USA Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v FCC Part 68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Canadian Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi CS-03 Issue 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi SH-03 Version 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii Japanese Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii JATE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii Safety Warnings and Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix 1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Audience for This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Lucent Technologies Information Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Printed Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About Lucent Technologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 For More Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 About the PacketStar® PSAX Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Text Types Used in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 .1-5 .1-4 .1-4 .1-2 .1-2 .1-2 .1-2 .1-2 .1-1 .1-1 .1-1 .1-1 .1-1 .1-1 1-1 ix .vii .vii .vii vi vi v v v v iv iv iv iii iii iii iii iii

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Electroststic Discharge Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Grounding Wrist Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Floor Covering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Temperature and Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Clothing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Handling Multiservice Media Gateway System Components . . . . . . . . . . . . . . . . . . . 1-7 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 2 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Overview of This Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Chassis Speed, Power Consumption, and Memory Allocation. . . . . . . . . . . . . . . . . . 2-3 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 3 Configuring Ports and Channels Using the Console . . . . . . . . . . . . . . . . . . . .3-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Loopback Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Configuring the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Configuring the 6-Port DS1 IMA Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Configuring the IMA Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 IMA Port and Channel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 IMA Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Saving Equipment Configuration and Logging Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18 4 Configuring Ports and Channels Using the AQueView® System . . . . . . . . . .4-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Loopback Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using the Right-Click Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Configuring Ports and Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Context-Sensitive Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Configuring the 6-Port DS1 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Configuring the Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 IMA Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 4-5 4-5 4-4 4-3 4-2 4-2 4-1 4-1 4-1 4-1 3-18 3-13 3-12 3-8 3-3 3-3 3-3 3-2 3-1 3-1 3-1 2-4 2-3 2-3 2-3 2-2 2-1 2-1 1-7 1-7 1-7 1-7 1-7 1-6 1-6 1-6 1-6

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Copying a Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10 Channel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11 Viewing Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13 IMA Virtual Channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13 IMA Virtual Channel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-14 Virtual Channel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-14 Viewing Channel Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-18 IMA Channel Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-18 5 Configuring the Interfaces Using the Console. . . . . . . . . . . . . . . . . . . . . . . . 5-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 Errors in Applying Interfaces to Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 ATM IMA Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 Automatic Use of IMA Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 IMA Configuration Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 Accessing the ATM IMA Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 ATM IMA Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-4 Activating the IMA Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Interim Interswitch Signaling Protocol (IISP) Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Optimizing SVC Call Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Configuring the ATM IISP Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7 ATM User-Network Interface 3.0, 3.1, and 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-11 Configuring the Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-11 Viewing ATM UNI Interface Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-16 Configuring ATM UNI ILMI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-18 Displaying Registered Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-20 Viewing ILMI Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-21 ATM Private Network-Network Interface (PNNI) 1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23 Optimizing SVC Call Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23 Configuring the ATM PNNI 1.0 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-24 Configuring PNNI ILMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-30 Viewing PNNI ILMI Interface Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-33 Viewing PNNI Interface Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-34 Changing PNNI Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-36 Changing the Non-administrative Weight Values for the ATM PNNI Interface . . . . . .5-36 6 Configuring the Interfaces Using the AQueView® System . . . . . . . . . . . . . . 6-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1 Errors in Applying Interfaces to Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1 .6-1 .6-1 6-1 .5-36 .5-36 .5-34 .5-33 .5-30 .5-24 .5-23 .5-23 .5-21 .5-20 .5-18 .5-16 .5-11 .5-11 .5-7 .5-6 .5-6 .5-6 .5-4 .5-3 .5-2 .5-2 .5-2 .5-1 .5-1 5-1 .4-18 .4-18 .4-14 .4-14 .4-13 .4-13 .4-11 .4-10

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 ATM IMA Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Automatic Use of IMA Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 IMA Configuration Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Accessing the ATM IMA Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Copying an Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 Interim Interswitch Signaling Protocol (IISP) Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Setting Up the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Adding NSAP Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12 Copying an Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14 Viewing Interface Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 Interface Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17 ATM User-Network Interface (UNI) 3.0, 3.1, and 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Setting Up the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Adding NSAP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26 Copying an Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-28 Viewing ATM UNI Interface Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29 Interface Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31 Configuring the Integrated Link Management Interface (ILMI) . . . . . . . . . . . . . . . . 6-34 Setting Up the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-34 Viewing Registered Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37 Viewing ILMI Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-38 ATM Private Network-Network Interface (PNNI) 1.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-39 Setting Up the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-39 Adding NSAP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-45 Copying an Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-47 Viewing Interface Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-48 Interface Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-50 Configuring the Integrated Link Management Interface (ILMI) . . . . . . . . . . . . . . . . 6-53 Setting Up the Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-53 Viewing Registered Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-57 Viewing ILMI Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-57 Changing PNNI Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-58 Changing the Non-administrative Weight Values for the ATM PNNI Interface . . 6-58 7 Provisioning Connections Using the Console Interface. . . . . . . . . . . . . . . . . .7-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Data Flow in PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Provisioning PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Adding ATM-to-ATM VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 7-4 7-2 7-2 7-1 7-1 6-58 6-58 6-57 6-57 6-53 6-53 6-50 6-48 6-47 6-45 6-39 6-39 6-38 6-37 6-34 6-34 6-31 6-29 6-28 6-26 6-20 6-20 6-17 6-15 6-14 6-12 6-8 6-7 6-6 6-2 6-2 6-1 6-1

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Viewing ATM-to-ATM VCC PVC Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12 Adding/Viewing a Backup PVC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-14 Adding ATM-to-ATM VPC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-16 Creating a ATM-to-ATM VPC Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-16 Viewing ATM-to-ATM VPC Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-23 Adding/Viewing a Backup ATM-to-ATM VPC Connection. . . . . . . . . . . . . . . . . .7-25 Adding Bridge-to-ATM VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-28 Creating a Bridge-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-28 Viewing Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33 Creating Backup PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-36 Adding Circuit Emulation-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . .7-38 Creating a Circuit Emulation-to-ATM VCC Connection. . . . . . . . . . . . . . . . . . . .7-38 Connection Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-46 Backup Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-48 Adding Frame Relay-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . .7-50 Creating a Frame Relay-to-ATM VCC PVC Connection . . . . . . . . . . . . . . . . . . . .7-50 Configuring Traffic Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-55 Viewing the Statistics Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-57 Adding an In-Band Management ATM PVC Connection. . . . . . . . . . . . . . . . . . . . . .7-60 Creating an In-Band-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . .7-60 Setting PVC Connections for Direct In-band Connections. . . . . . . . . . . . . . . . . .7-65 Adding VBR-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-67 Creating a VBR-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-67 Viewing the VBR-to-ATM Connection Statistics . . . . . . . . . . . . . . . . . . . . . . . . .7-74 Adding/Viewing a Backup PVC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-77 Adding VBR-to-VBR VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-79 Adding AAL-2 Trunking to a Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-86 Configuring an AAL2 Trunking Connection with DSP Parameters. . . . . . . . . . . . . . .7-87 Provisioning SVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-94 Viewing ATM-to-ATM VCC SVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-94 Enabling SVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-95 Setting Up a PNNI Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-95 Setting Up an IISP Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-96 Adding Entries to the ATM IISP CBR Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . .7-96 Creating IISP VBR Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-96 Adding Entries to the ATM IISP VBR Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . .7-98 Creating IISP VBR Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-98 Provisioning SPVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-99 Adding ATM-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-99 .7-99 .7-99 .7-98 .7-98 .7-96 .7-96 .7-96 .7-95 .7-95 .7-94 .7-94 .7-87 .7-86 .7-79 .7-77 .7-74 .7-67 .7-67 .7-65 .7-60 .7-60 .7-57 .7-55 .7-50 .7-50 .7-48 .7-46 .7-38 .7-38 .7-36 .7-33 .7-28 .7-28 .7-25 .7-23 .7-16 .7-16 .7-14 .7-12

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Creating an ATM-to-ATM VCC SPVC Connection . . . . . . . . . . . . . . . . . . . . . . . 7-99 Viewing Connection Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-106 Adding NSAP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-108 Adding Circuit Emulation-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . 7-109 Creating a Circuit Emulation-to-ATM Connection . . . . . . . . . . . . . . . . . . . . . . 7-109 Viewing Connection Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-115 Adding VBR-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-117 Creating a VBR-to-ATM Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-117 Viewing Connection Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-122 Adding Frame Relay-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . . . . . 7-124 Creating a Frame Relay-to-ATM VCC SPVC Connection . . . . . . . . . . . . . . . . . 7-124 Configuring Traffic Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-130 Viewing Connection Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-133 8 Provisioning Connections Using the AQueView® System . . . . . . . . . . . . . . .8-1 Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Data Flow in PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Managing Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Searching for Specific Connection Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Viewing Connection Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Displaying and Updating Connection Information. . . . . . . . . . . . . . . . . . . . . . . . 8-5 Display Connection Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 Copying a Connection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 Filtering Connections in the List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 Filtering the Listing Page by Connection Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 Filtering the Listing Page by PSAX Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11 SPVC NSAP Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 AAL2 Trunk Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13 Configuring AAL2 Trunking with DSP Processing . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13 Adding an AAL2 Trunk Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15 Deleting an AAL2 Trunk Entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20 Creating Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21 Using the Right-Click Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22 Connection Provisioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22 Context-Sensitive Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23 Provisioning PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23 Adding ATM-to-ATM VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23 Creating an ATM-to-ATM VCC Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-29 8-29 8-23 8-23 8-23 8-23 8-22 8-22 8-21 8-20 8-15 8-13 8-13 8-12 8-11 8-9 8-9 8-6 8-6 8-5 8-5 8-3 8-2 8-2 8-1 8-1 7-133 7-130 7-124 7-124 7-122 7-117 7-117 7-115 7-109 7-109 7-108 7-106 7-99

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-30 Polling Statistics Using the Odometer Delta . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-33 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-34 Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-35 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-37 Adding ATM-to-ATM VPC VCC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-39 Creating an ATM-to-ATM VPC Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-39 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-45 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-46 Polling Statistics Using the Odometer Delta . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-49 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-50 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-53 Adding Bridge-to-ATM VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-55 Creating a Bridge-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-55 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-60 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-61 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-64 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-67 Adding Circuit Emulation-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . .8-69 Creating a Bridge-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-69 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-73 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-74 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-77 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-80 Adding Frame Relay-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . .8-82 Creating a Frame Relay-to-ATM Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . .8-82 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-87 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-88 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-91 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-93 Adding an In-Band Management ATM PVC Connection. . . . . . . . . . . . . . . . . . . . . .8-96 Disabling an SVC Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-96 Creating an In-Band-to-ATM Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-99 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-103 Backup Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-104 Adding VBR-to-ATM VCC PVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-107 Creating a VBR-to-ATM VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-107 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-113 Statistics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-114 .8-114 .8-113 .8-107 .8-107 .8-104 .8-103 .8-99 .8-96 .8-96 .8-93 .8-91 .8-88 .8-87 .8-82 .8-82 .8-80 .8-77 .8-74 .8-73 .8-69 .8-69 .8-67 .8-64 .8-61 .8-60 .8-55 .8-55 .8-53 .8-50 .8-49 .8-46 .8-45 .8-39 .8-39 .8-37 .8-35 .8-34 .8-33 .8-30

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Backup Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-117 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-120 Adding VBR-to-VBR VCC PVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-122 Creating a VBR-to-VBR VCC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-122 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-127 Statistics Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-128 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-129 Provisioning SVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-132 Enabling SVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-132 Setting Up a PNNI Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-132 Setting Up an IISP Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-132 Editing ATM-to-ATM VCC SVC Connection Entries . . . . . . . . . . . . . . . . . . . . . . . . 8-133 Viewing or Editing an ATM-to-ATM SVC Connection . . . . . . . . . . . . . . . . . . . 8-133 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-134 Statistics Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-138 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-140 Configuring IISP Routing Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-143 Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-144 Creating a VBR or CBR Routing Table Entry. . . . . . . . . . . . . . . . . . . . . . . . . . . 8-145 Deleting a Routing Table Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-148 Provisioning SPVC Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-150 Adding ATM-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-150 Creating an ATM-to-ATM Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-150 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-156 Statistics Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-158 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-160 Adding Circuit Emulation-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . 8-162 Creating a Circuit Emulation-to-ATM Connection . . . . . . . . . . . . . . . . . . . . . . 8-162 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-168 Statistics Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-170 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-172 Adding VBR-to-ATM VCC SPVC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-175 Creating a VBR-to-ATM Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-175 Primary Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-181 Statistics Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-182 Utilization Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-185 Deleting a Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-188 8-188 8-185 8-182 8-181 8-175 8-175 8-172 8-170 8-168 8-162 8-162 8-160 8-158 8-156 8-150 8-150 8-150 8-148 8-145 8-144 8-143 8-140 8-138 8-134 8-133 8-133 8-132 8-132 8-132 8-132 8-129 8-128 8-127 8-122 8-122 8-120 8-117

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Appendix A: Pin Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Overview of This Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Configuration for the DS1/T1/E1 Interface Cable Connector. . . . . . . . . . . . . . . . . . . . . . A-1 Appendix B: Reference Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Overview of This Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 ATM Traffic Descriptors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Purpose of Traffic Descriptors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Connections Supporting Traffic Descriptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 ATM User-Network Interface Specification Cause Codes Table . . . . . . . . . . . . . . . . . . . . .B-3 Connection Retry Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3 DSP Tone Detection Modes Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 DSP2C Module Channel Reduction Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 Industry Compliance Specifications Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-6 Interface Type by Connection Type Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-26 Interface Type by I/O Module Type Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-27 Minimum AAL2 Trunk Size Requirements Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-31 Example Using Table B-7 Data for 32 Kbps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-32 Fax Relay Using AAL2 Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-32 Module Alarm Status Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-33 Quality of Service (QoS) Information Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-34 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary-1 .B-34 .B-33 .B-32 .B-32 .B-31 .B-27 .B-26 .B-6 .B-5 .B-5 .B-3 .B-3 .B-1 .B-1 .B-1 .B-1 B-1 A-1 A-1 A-1

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 255-700-166 1-1 1 Getting Started Purpose of This Guide The PacketStar® 6-Port DS1 IMA Module User Guide provides information about the following: • Configuring the ports, channels, and interfaces for the 6-Port DS1 IMA module • Provisioning connections for permanent virtual circuits (PVCs), switched virtual circuits (SVCs), and soft permanent virtual circuits (SPVCs) Note: If you are using this module to provision connections for the first time, you should read through this guide before beginning the provisioning process. Audience for This Guide The information in this guide is intended for users who will configure ports and channels for the 6-Port DS1 IMA module, configure the interface types, and provision connections for the PSAX Multiservice Media Gateway system, whether using the console or the AQueView® element management software system. What You Should Know Before you use this document or operate a PacketStar® PSAX device, you should already understand and have experience with the following: • ATM Forum and Frame Relay Forum specifications • Ethernet network capabilities • Internet Protocol capabilities • Data network design • Telephony network design Related Reading Lucent Technologies Information Products Product Information Library To install and configure your Multiservice Media Gateway system and I/O or server modules, read the PSAX publications provided on your Lucent

Chapter 1 Getting Started

About Lucent Technologies 1-2 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Technologies PacketStar® PSAX Multiservice Media Gateways Central Office (CO) Products, Product Information Library CD-ROM. Printed Documents For your convenience, many of the documents included on the PacketStar® Multiservice Media Gateway Central Office (CO) Products Product Information Library CD-ROM are also available in printed form. You can order these documents through the Lucent Technologies Customer Information Center Web site at: www.lucentdocs.com. Other Publications Numerous books are currently available on the subject of basic telecommunications technology and specific protocols. In addition to such general reading, you should also be familiar with the specifications identified in the appendix entitled Reference Tables at the back of the guide. About Lucent Technologies History Lucent Technologies is the communications systems and technology company formed through the restructuring of AT&T. We bring with us a tradition of more than 125 years of experience and a dedication to superior customer service. Lucent Technologies manufactures, sells, and services a complete line of customer premises communications units, and commercial and multimedia communications and messaging systems designed and supported by our research and development unit, Bell Laboratories. Our legacy and our spirit of innovation allow Lucent to provide our customers with the tools needed to communicate effectively, any time and anywhere, and to integrate the latest technologies into real-life solutions that help make business work. For More Information To learn more about the PacketStar® PSAX family of ATM Multiservice Media Gateways and the complete line of Lucent Technologies products, visit our Web site at www.lucent.com. About the PacketStar® PSAX Product Family Lucent Technologies provides a complete range of PSAX Multiservice Media Gateways in the PacketStar® PSAX family, as described in Table 1-1.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 1 Getting Started About the PacketStar® PSAX Product Family Table 1-1. PacketStar® PSAX Product Family Target Market Device Name Application/Description Small Customer Premises PSAX 20 The PacketStar® PSAX 20 Multiservice Media Gateway is the most scalable and flexible multiservice access product in its class. This scal- ability enables service providers to meet the demands of a growing enterprise customer with a single-edge solution. The PSAX 20 system is nonredundant. Supporting two slots for I/O and server modules and two factory- installed components (Enhanced DS1 and DSP2C Voice Server) and a 600 Mbps ATM cell bus architecture, this system optimizes wide area network (WAN) bandwidth with toll-quality voice compression, traf- fic optimization, and port scalability from T1/E1 to OC-3c/STM-1c connections. It also supports a full range of interfaces such as DS1, DS3, 10/100Base-T Ethernet, and serial. Small Customer Premises PSAX AC 60 The PacketStar® PSAX AC 60 Multiservice Media Gateway is ideal for enterprise networks seeking to consolidate branch office voice, video, and data traffic onto a single ATM network. The PSAX AC 60 system is nonredundant. Supporting four slots for I/O and server modules, this system offers high port-density in a small footprint for mid- to large-sized customer premises applications. The PSAX AC 60 chassis has a 650 Mbps back- plane and supports a full range of interfaces such as DS1/E1, DS3/E3, OC-12c/STM-4c, 10/100Base-T Ethernet, and serial. Carrier-Class Office PSAX 1250 The PacketStar® PSAX 1250 Multiservice Media Gateway is designed to provide a full range of central office-based multiservice ATM access functions. Ideal for the central office or a large enterprise’s multiser- vice media gateway, the PacketStar® PSAX 1250 system provides highly reliable network access for time-division multiplex voice, frame relay, and ATM data applications. Supporting ten slots (19-inch chassis) or 14 slots (23-inch chassis) for I/O and server modules, a 1.2 Gbps ATM cell bus architecture, carrier- class reliability, full redundancy, and a full range of interfaces such as DS1/E1, DS3/E3, OC-12c/STM-4c, 10/100Base-T Ethernet, and serial, the PSAX 1250 system is a cost-effective access switch solution for bridging to legacy equipment.

Chapter 1 Getting Started

Text Conventions 1-4 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Text Conventions Text Types Used in This Document This book uses a different kind of type for each kind of text you will see on screens and equipment. In general, text you see in the book will closely Carrier-Class Office PSAX 2300 The PacketStar® PSAX 2300 Multiservice Media Gateway offers car- rier-grade, high-density multiservice ATM access functions. Designed as the multiservice media gateway for the central office or for a large enterprise customer, the PacketStar® PSAX 2300 system provides net- work access for time-division multiplex voice, frame relay, and ATM data applications. Supporting 15 slots for I/O and server modules, a 3.9 Gbps ATM cell bus architecture, carrier-class reliability, full redundancy, provisions for OC-12c/STM-4c interfaces, N x T1/E1 module protection switch- ing, and a full range of interfaces such as DS1/E1, DS3/E3, 10/100Base-T Ethernet, and serial the PSAX 2300 system solves many demanding and diverse network design challenges with ease. Carrier-Class Office PSAX 4500 The PacketStar® PSAX 4500 Multiservice Media Gateway offers up to 10 Gbps of switching capacity, the highest in the PacketStar® family, and carrier-class reliability. The PSAX 4500 system offers an unmatched range of service capabilities, end-to-end traffic prioritiza- tion, “any-service, any-channel” flexibility, and breakthrough voice technology. The new high-performance backplane design supports 15 interface slots. In four segments, the unique PSAX 4500 backplane allows each seg- ment to be scaled independently to provide nonblocking, redundant chassis bandwidths beyond 10 Gbps. Protection for two groups of four multiport DS3, STS-1e, and E3 modules is provided via an N:1 protec- tion scheme using rear access line interface modules. The protection module can fill in so that on the failure of any one of the four mod- ules, traffic is maintained. Using the latest voice-compression technology, the DSP2x Voice Server modules deliver service providers eight times the capacity of traditional time division multiplex circuits while maintaining toll quality and reducing costs by nearly 30 percent per channel. A single PSAX 4500 system at the edge of the carrier network can transition traffic from a large number of network customers over high-speed OC-12c/STM-4c trunks into the ATM core, managing the whole quickly and efficiently, down to the individual permanent virtual cir- cuit. Table 1-1. PacketStar® PSAX Product Family Target Market Device Name Application/Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 1 Getting Started Text Conventions resemble what you see on the screens and equipment. The following table shows how each typographical convention is used. Icons and Symbols Standard icons and symbols to alert you to dangers and cautions are listed below. ! DANGER: Warnings for a personal injury hazard are identified by this format. WARNING: ! Warnings relating to risk of equipment damage or failure are identified by this format. ! CAUTION: Warnings relating to risk of data loss or other general precautionary notes are identified by this format. Note: Identifies additional information pertinent to the text preceding this note. Appearance How it is used SANS SERIF BOLD, ALL CAPS Labels on module panels, chassis face- plates, or other hardware Fixed-width normal Message text displayed on the user interface window Serif bold • Button name (GUI interface) or command name (console interface) on the user interface window • Literal text for values that the user types in fields or selects from pre- defined sets of values for fields • Command keywords or literal argu- ment values Fixed-width bold System prompt displayed on the user interface window Serif italics • A variable name or string for which you will substitute your own infor- mation • An argument or parameter on a command line for which you will substitute your own information

Chapter 1 Getting Started

Electroststic Discharge Precautions 1-6 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Electroststic Discharge Precautions The room where the Multiservice Media Gateway system is located must have built-in precautions to provide protection from electrostatic discharge damage to electronic components. The following sections provide details on these necessary precautions. Grounding Wrist Straps Attach at least one grounding wrist strap to a common ground for each chassis/electronic rack to be handled. Follow these guidelines for wrist straps: • Make sure the wrist straps or wrist strap cords have built-in 1-megaohm (minimum) resistance. • Make sure the wrist straps and wrist strap cords are UL listed. • Ensure the wrist strap cord is long enough so it can be worn while working either at the front or the back of the rack. • Always discharge any static charge by touching your wrist strap before you touch the Multiservice Media Gateway chassis. Floor Covering Be sure the room has an antistatic floor covering (conductive mat, tiles, or carpeting) to minimize static charge buildup as you walk across the room. Follow these guidelines for installing and maintaining proper floor coverings: • Using foot grounding straps (attached to the heels of your shoes) is recommended, even if you are walking in rooms with antistatic floor covering. These straps provide additional protection against electrostatic discharge. The straps should have built-in 1-megaohm (minimum) resistance. • Wool carpet is not an acceptable floor covering. • Other types of carpet must be sprayed daily with a topical antistatic chemical before you perform any work in the room. Paying constant attention to carpet maintenance is time-consuming but required, if used. Temperature and Humidity Establishing the proper temperature and humidity in the room where the Multiservice Media Gateway system is located helps control many static discharge problems. Maintaining proper room climate is especially important when heat is turned on during the cold weather. To avoid damage to the Multiservice Media Gateway system, do not allow the humidity to increase to the level where water droplets appear on surfaces.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 1 Getting Started Technical Support Clothing When working with the Multiservice Media Gateway system, avoid wearing clothing made from wool or synthetic materials. Try to minimize contact between clothing and electronic components. Handling Multiservice Media Gateway System Components Follow these guidelines for proper handling of the Multiservice Media Gateway hardware to minimize electrostatic discharge damage: • Do not remove the chassis, modules, and other items from their protective packaging until you are ready to install them. • When installing modules and components, use a grounding wrist strap connected to a common electrical ground to prevent electrostatic discharge damage. (A common electrical ground is a complete circuit between a person or an electrical/electronic device and the earth.) • Store components in electrostatic-discharge-protective bags when they are not in use. Technical Support If you experience a problem with your Multiservice Media Gateway system, refer to the Lucent Technologies InterNetworking Systems Global Warranty, which accompanied your shipment, for instructions on obtaining support in your area. Comments on This Guide To comment on the PacketStar® PSAX 6-Port DS1 IMA Module User Guide, please complete the comment card that accompanied your shipment and mail it to the following address: Manager, Information Design and Development Team Lucent Technologies PacketStar® PSAX Products 8301 Professional Place Landover, MD 20785 USA You can also fax the comment card to us at: 301-809-4540. Before You Begin Before you start setting up, configuring, and using your new Multiservice Media Gateway system, be sure you complete the following:

Chapter 1 Getting Started

Before You Begin 1-8 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 • Carefully read the safety cautions listed in the section, “Safety Information,” at the beginning of this guide. • Record your site-specific specifications such as the IP addresses you will use, and the connections and interfaces you will need. Decide which user names and passwords you will assign. • Make sure you have IP connectivity to all PSAX devices to be managed. • Determine the numbering scheme for the in-band connections you will be using.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 255-700-166 2-1 2 Module Description Overview of This Module The 6-Port DS1 IMA module (see Figure 2-1) has six physical RJ-45 ports. Inverse multiplexing over ATM permits a user to strap two to six of the physical ports together to create ATM interfaces that support 3–9 Mbps of bandwidth. A maximum of three IMA groups may be configured per module. Source data enters the module from the backplane and is divided between the ports within the IMA group specified in the virtual circuit connection. The data leaves the front of the module and is transported across individual T1 lines. At the destination IMA module, the T1 streams are merged back together in correct order and passed on to other modules as directed by virtual circuit connections. IMA dynamically handles conditions when T1s within an IMA group become unavailable: the IMA "pipe" shrinks in bandwidth to the remaining T1s and continues to pass traffic. When a problem T1 comes back on line, the IMA "pipe" will enlarge to take full advantage of the restored bandwidth.

Chapter 2 Module Description

Software Features 2-2 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Figure 2-1. DS1 IMA Module Software Features The 6-Port DS1 IMA module offers native DS1 ATM services and DS1 IMA services, including permanent virtual circuits, soft permanent virtual circuits, and switched virtual circuits. The module supports UNI v3.a, IISP, PNNI, and ILMI. This functionality enables service providers to offer both individual unchannelized DS1 ATM services (without IMA overhead) and multiple DS1 IMA group services using a single module. ACTIVE IMA DS1 FAIL 6 1 5 4 3 2

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 2 Module Description Hardware Features Hardware Features The 6-Port DS1 IMA module provides the following hardware features: • Number of ports: 6 • Connector type: RJ-45 • Line rate: 1.544 Mbps • Line encoding mode: B8ZS • Loopback capabilities: local loopback, line loopback, payload loopback • Line buildout: Up to 133, 266, 399, 533, and 655 feet; negative 7-5 dB, negative 15 dB, negative 22-5 dB. • Framing mode: cyclic redundancy check multifrequency (CRC-mf) Hardware Specifications Table 2-1 shows the general physical and environmental hardware specifications for the PSAX Multiservice Media Gateway I/O and server modules. Chassis Speed, Power Consumption, and Memory Allocation Chassis speed, power consumption, and memory allocation specifications for the 6-Port DS1 IMA module are described in Table 2-2. Table 2-1. Physical Hardware Specifications for the I/O and the Server Modules Specification Description Dimensions: • Height: • Width: • Depth: 15.74 cm (6.2 in.) 2.41 cm (0.95 in.) 24.13 cm (9.5 in.) Weight: 0.45 kg (1.0 lb.) Operating temperature: 0° to 50° C (32° to 122° F) Operating relative humidity: 40 to 60%, optimum; up to 95%, noncondensing Storage temperature: -20° to 70° C (-4° to 158° F)

Chapter 2 Module Description

Hardware Features 2-4 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 LED Indicators Table 2-3 describes how the light-emitting diode (LED) indicators on the 6-Port DS1 IMA module faceplate respond to different module conditions. These LEDs indicate if the module has been installed properly. Table 2-2. Chassis Speed, Power Consumption, and Memory Allocation Specifications Module Total Amount of SDRAM Module Program and Data Space Maximum Input Buffer 1 Output Buffer Chassis Speed 2 Power Con- sumption 6-Port DS1 IMA (IMA DS1) 16–64 MB 8 MB 1 MB Total minus 9 MB Low Speed 18 W 1 The I/O buffers carry 16,384 cells per megabyte. 2 This column relates only to the performance of the module in the PSAX 4500 chassis. All modules operate in a low- speed mode in all other PSAX chassis. The speed relates to the performance of the data being passed through the midplane of the chassis. Table 2-3. LED Indicators for the 6-Port DS1 IMA Module Initial Power-On No Configured Ports One or More Configured Ports No Cable on Port Cable on Port FAIL (red) Lights briefly1 Not lit Lights only when the module is not func- tioning N/A N/A ACTIVE (green) Lights briefly1 Not lit Lights only when the module is function- ing prop- erly N/A N/A LED Module Status

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 2 Module Description Hardware Features LOS [Loss of Signal] 1 (yellow) 2 (yellow) 3 (yellow) 4 (yellow) 5 (yellow) 6 (yellow) Lights briefly2 N/A N/A Lights • Does not light if sig- nal is being received • Lights if signal is missing 1Note: After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green). 2Note: After power is initially applied to the system and the system boot is complete, this loss of signal LED indicates whether the port has a cable connected to it. Table 2-3. LED Indicators for the 6-Port DS1 IMA Module Initial Power-On No Configured Ports One or More Configured Ports No Cable on Port Cable on Port LED Module Status

Chapter 2 Module Description

Hardware Features 2-6 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 255-700-166 3-1 3 Configuring Ports and Channels Using the Console Overview of This Chapter This chapter describes how to set the values for the port and channel configuration for the 6-Port DS1 IMA module using the PSAX Multiservice Media Gateway system console interface. Before You Begin Be sure to complete the following actions first before configuring the 6-Port DS1 IMA module: • Configure your basic system (see "Configuring the System for Your Site" in Chapter 4 of the appropriate PacketStar® PSAX Multiservice Media Gateway user guide) • Configure the Stratum 3–4 module (see "Configuring the Stratum 3–4 Module" in Chapter 4 of the appropriate PacketStar® PSAX Multiservice Media Gateway user guide) When configuring the 6-Port DS1 IMA module using the PSAX Multiservice Media Gateway console, display-only fields are displayed with brackets. The status line at the bottom of the console window gives instructions for the field currently selected, and displays trap messages (see the appendix of your chassis user guide for a table of defined trap messages). The configuration of the 6-Port DS1 IMA module involves the following major tasks: 1. Each port must be configured with the IMA interface, and that IMA interface must be brought into service. 2. Each IMA group must be established. 3. Each IMA group must be configured with an ATM interface (IISP, UNI, or PNNI). ! CAUTION: When using a DSP2A, DSP2B, DSP2C, or DSP2D Voice Server module and an Enhanced DS1 or E1 module with a PBX and/or key telephone system, the Multiservice Media Gateway system and your equipment should use a common chassis ground connection to avoid ground current loops, which could affect voice quality.

Chapter 3 Configuring Ports and Channels Using the Console

Loopback Configuration Options 3-2 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Loopback Configuration Options To aid network troubleshooting and testing, loopback capability is provided for the 6-Port DS1 IMA module. The loopback option on the module’s port and channel configuration window for the module enables you to verify the integrity of a port by transmitting a received signal back to the source. Selecting a loopback option is described in the module configuration procedure provided in this chapter. If configuring a pair of 6-Port DS1 IMA module in the primary and standby setup, the desired loopback option must be configured by the user on both the primary and standby modules prior to bringing the pair into service. This parameter is applied on a port-by-port basis on both the primary and standby modules. If the line loop or local loop configuration is transferred from port A on the primary module to port B on the standby module, the port parameter does not transfer; it must be pre-configured on the standby by the user. Figure 3-1 illustrates the line loop, payload loop, and local loop options. The following I/O modules have loopback capability: • 6-Port Enhanced DS1/T1 Multiservice module • 6-Port DS1 IMA module • 12-Port Medium-Density DS1 Multiservice module Figure 3-1. Loopback Configuration Options on Certain I/O Modules

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module • 6-Port Enhanced E1 Multiservice module • 6-Port E1 IMA module • 21-Port High-Density E1 Multiservice module • 1-Port Channelized DS3 Multiservice and CES modules • 1-Port Channelized Channelized STS-1e, T1 Format module • 2-Port DS3 ATM module • 1-Port Unchannelized DS3 Frame Relay module • 1-Port DS3 IMA module • 3-Port Channelized DS3/STS-1e CES module • 3-Port Unstructured DS3/E3 CES module (payload loop not supported) • 2-Port E3 ATM module • 1-Port OC-3c Multimode and Single-Mode (Traffic Shaping and AQueMan) modules • 1-Port STM-1 Multimode and Single-Mode (Traffic Shaping and AQueMan) modules The following modules support line loop or local loop only if the standby is preconfigured on a port-by-port basis: • 1-Port OC-3c 1+1 APS Multimode and Single-Mode modules • 1-Port STM-1 1+1 MSP Multimode and Single-Mode modules • 1-Port OC-12c/STM-4c 1+1 APS/MSP Multimode and Single-Mode modules Configuring the Module The 6-Port DS1 IMA module has 6 physical DS1 ports that may be used for native DS1 ATM services or for DS1 IMA groups. You must first configure the DS1 IMA module before you can set up connection provisioning. Configuring the 6-Port DS1 IMA Module Configuring the IMA Ports To configure the 6-Port DS1 IMA module ports, perform the steps in the following procedure.

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-4 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Begin Configuring the Ports 4 On the Console Interface Main Menu window (see Figure 3-2), select the Equipment Configuration option and press Enter. The Equipment Configuration window is displayed (see Figure 3-3 and Figure 3-4) . Figure 3-2. Console Interface Main Menu Window (Equipment Configuration Selected)

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Figure 3-3. Equipment Configuration Window (As Displayed on the PSAX 20, and AC 60 Console) Figure 3-4. Equipment Configuration Window (As Displayed on the PSAX 1250 and PSAX 2300 Console)

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-6 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 5 On the Equipment Configuration window, select a 6-Port DS1 IMA module in the list and press Enter. The DS1 IMA Card Configuration window is displayed (see Figure 3-5 on page 3-6). Commands The commands in these windows have the following functions Figure 3-5. DS1 IMA Card Configuration Window Command Function • Update Display Updates the values in the fields to show the most current configuration. Use this command mostly to display the most current information in the Line Status field. • Delete All Interfaces Deletes the configured interfaces for all the ports. The value 0 displays in the # Channels Configured field. You must first take all interfaces out of service (using the Take All Interfaces Out Of Service command) before you can use this command to delete all the configured interfaces. • Bring All Interfaces Into Service Brings the out-of-service configured interfaces for all the ports to in-service status. The num- ber of interfaces in service displays in the # Interfaces In Service field for all the ports.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module 6 Select one of the lines with the port you want to configure and press Enter. The DS1 IMA Port and Channel Configuration window is displayed (see Figure 3-6). Commands The commands in the DS1 IMA Port and Channel Configuration window have the following functions: • Take All Interfaces Out Of Service Takes the in-service configured interfaces for all the ports to out-of-service status. The value 0 displays in the # Interfaces In Service field for all six ports. You must use this command first before using the Delete All Interfaces command. • Go Back to Equipment Configuration Redisplays the Equipment Configuration win- dow. Figure 3-6. DS1 IMA Port and Channel Configuration Window Command Function

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-8 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 End IMA Port and Channel Configuration To set values for the DS1 IMA Port and Channel Configuration window, perform the steps in the following procedure. Setting the Values for the DS1 IMA Port and Channel Configuration Begin Window 1 Select the values for the fields on the Port and Channel Configuration windows from the values given in Table 3-1. Command Function • Apply Port Configura- tion For a specified port number value, applies the port configuration field values you set • Reset Display Resets the port configuration fields to the last set of saved values. • View Port Statistics Displays the IMA Port Statistics window. • Bring Interface Into Service Brings the out-of-service configured inter- face for the channel to in-service status. An asterisk is displayed beside all the con- figured channels indicating that they are in service. You must first configure the interface before you can use this command. • Take Interface Out Of Service Takes the in-service configured interface to out-of-service status. The displayed asterisk is removed from all configured channels indicating that they are out of service. Note: You must use this command first before using the Delete All interfaces On This Port command. • Go Back to Card Con- figuration Redisplays the IMA Card Configuration window.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Table 3-1. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description Line Type Default: Esf Extended Super Frame DS1 format. (display only) D4 D4 format. Channels are assigned sequentially. Line Coding (display only) Default: B8ZS Bipolar with 8 zero substitution. Use of a specified pattern of normal bits and bipolar violations to replace sequence of 8 zero bits. Ami Alterable mark inversion. Indicates zero code suppression. Loopback Con- fig Default: NoLoop The port is not in loopback state. LocalLoop The signal is received from another module in the chassis, sent through the module circuitry, including the segmen- tation and reassembly (SAR) function, and the chassis backplane to the origi- nating module. PayloadLoop The received signal is sent through the framing chip on the module, but not the SAR circuitry, and then back out to the originating point. The data link is regenerated. LineLoop The received signal is sent through the receiver and the line driver, and then back out to the originating point. Transmit Clock Default: LocalTiming Local clock source is used as the timing source. LoopTiming Recovered receive clock is used as the transmit clock Line Build Out Default: Up To 133 Feet Indicates the DS1 signal is designed to be valid from 0 to 133 feet Up To 266 Feet Indicates the DS1 signal is designed to be valid from 134 to 266 feet Up To 399 Feet Indicates the DS1 signal is designed to be valid from 267 to 399 feet Up To 533 Feet Indicates the DS1 signal is designed to be valid from 400 to 533 feet Up To 655 Feet Indicates the DS1 signal is designed to be valid from 534 to 655 feet negative7-5Db Indicates the T1 signal level range at which the DS1 is configured is negative 7.5 dB

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-10 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 negative15Db Indicates the T1 signal level range at which the DS1 is configured is negative 15 dB negative22-5Db Indicates the T1 signal level range at which the DS1 is configured is negative 22.5 dB Indicates the line status of the interface: loopback, failure, received and transmitted alarm information. See the bit map tables for the 6-Port DS1 IMA module under the MIB object lineStatus in Appendix A, "SNMP Trap Messages" in any PacketStar™ Access Concentrator User’s Guide. NoAlarm (default) No alarm is present. RcvFarEndLOF Far-end loss of frame. FarEndLOF Near-end sending loss of frame indication. RcvAIS Far-end sending alarm indication signal. AIS Near-end sending alarm indication signal. LossOfFrame Near-end loss of frame. LossOfSignal Near-end loss of signal. LoopbackState Near-end is looped. T16AIS E1 TS16 AIS. Rcv FarEndLOMF Far-end sending TS16 LOMF. FarEndLOMF Near-end sending TS16 LOMF. RcvTestCode Near-end detects a test code. OtherFailure Any line status not defined here. RmtLoopback Far-end loopback. Interface Type Unconfigured This interface is not configured Atm Ima This interface is configured as an IMA interface. Table 3-1. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module 2 To apply the values for the port fields, select the Apply Port Configuration command and press Enter. 3 Select the Configure Interface command and press Enter. The selected interface configuration window is displayed. See Chapter 5, "Configuring the Interfaces Using the AC Console," for instructions. 4 To bring the interface into service, select the Bring Interface Into Service command. Note: You must bring the interface into service before you can set up DS1 IMA groups. End [Admin Status] (display only) Unconfigured The interface for the port is not config- ured. OutOfService The interface has not yet been brought into service, or in-service interface has been set to out of service with the Take Interface Out of Service command. InService The interface has been brought into ser- vice with the Bring Interface Into Ser- vice command. [Oper Status] (display only) Unconfigured This channel is not operational because the interface is not configured. OutOfService Two types of problems cause this status. • A loss-of-signal condition exists due to any one of the following: ~ The module port is not physically connected to a cable. ~ The cable is not connected at the other end to a device. ~ The cable is broken. • A loss of frame or encoding exists due to a problem with the framing or encoding of the signal. For example, a repeater could corrupt the signal. InService The port is physically connected to a cable; the cable is conducting the signal; and the signal is being transmitted and received correctly. Table 3-1. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-12 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Port Statistics Begin Viewing DS1 IMA Port Statistics To view statistics for this port, perform the steps in the following procedure. 1 Select the View Port Statistics command and press Enter. The DS1 IMA Port Statistics window (see Figure 3-7) is displayed. Commands The commands in this window has the following functions: Figure 3-7. DS1 IMA Port Statistics Window Command Function • Continuous Update Updates the values in the fields every sec- ond. • Reset Statistics Sets all field values to zero. • Go Back to DS1 IMA Port Configuration Redisplays the DS1 IMA Port and Channel Configuration window.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module Data Fields for the Port Statistics Descriptions of the data fields for the DS1 IMA Port Statistics window are given in Table 3-2 on page 3-13 IMA Groups At this time, you can set up DS1 IMA groups for the DS1 IMA module. You can configure up to three IMA groups for each module, and each group can contain up to six ports. To set the values for the DS1 IMA groups, perform the steps in the following procedure. Up to 3 groups (channels) can be configured on the virtual port (port 7). A group must have at least two, and up to 6 of the physical ports assigned to it. For example: ~ You can assign all six of the physical ports to Group 1 (channel 1) ~ You can assign ports 1, 3, 5 to Group 1 (channel 1), and ports 2, 4, and 6 to Group 2 (channel 2), and so on. Perform the steps in the following procedure to set up the DS1 IMA groups. Begin Setting Up DS1 IMA Groups 1 To configure a DS1 IMA group, select the Go Back to Port Configuration command (or press Ctrl+B) to return to the DS1 IMA Port and Channel Configuration window (see Figure 3-6 on page 3-7). Table 3-2. Data Field Descriptions of the DS1 IMA Port Statistics Window Field Names Description Errored Seconds A second with at least one of the foll- wing: ~ Path Code Violations ~ Controlled Slip events ~ A detected AIS defect ~ Presence of Bipolar Violations. Severely Errored Seconds A second with at least one of the fol- lowing: ~ 320 or more Path Code Violation Error events ~ Out of Frame defects ~ A detected AIS defect ~ A count of one-second intervals with Framing error events, an OOF defect, or a minimum of 1544 LCVs. Line Coding Violations A Bipolar Violation or Excessive Zeroes Error Event has occurred. Time Elapsed Time elapsed since last reset.

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-14 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 2 On the DS1 IMA Port and Channel Configuration window, select the Go Back to Card Configuration command (or press Ctrl+B) to return to the DS1 IMA Card Configuration window (see Figure 3-5 on page 3-6). 3 On the DS1 IMA Card Configuration window, select port 7, which is a virtual port, and press Enter. The DS1 IMA Virtual Channel Configuration window is displayed (see Figure 3-8). Commands The commands in the DS1 IMA Virtual Channel Configuration window have the following functions: Figure 3-8. DS1 IMA Virtual Channel Configuration Window Command Function • Delete All Interfaces Deletes all configured, out-of-service interfaces. The value Unconfig displays in the status field for all interfaces that are deleted. Only the interfaces that are out of service can be unconfigured by this command. • Bring All Into Service Brings out-of-service configured interfaces to in-service status. An asterisk denoting in-service status displays in the status field.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module 4 Select the Configure Gp1 field and press Enter. The DS1 IMA Group Configuration window (see Figure 3-9) is displayed. Commands The commands in the DS1 IMA Group Configuration window have the following functions: • Take All Out of Service Takes the in-service configured interfaces to out-of-service status. An asterisk denoting in-service is removed from the status field, indicating out-of-service sta- tus. • Go Back to Card Con- figuration Redisplays the IMA Card Configuration window. Figure 3-9. DS1 IMA Group Configuration Window Command Function Command Function • Apply IMA Group Con- figuration Applies the configuration field values you set. • Reset IMA Group Dis- play Resets the port configuration fields to the last set of saved values.

Chapter 3 Configuring Ports and Channels Using the Console

Configuring the Module 3-16 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Field Descriptions Select the values for the fields on the DS1 IMA Group Configuration window from the values given in Table 3-3. • Bring Interface Into Service Brings the out-of-service configured interface for the channel to in-service status. You must first configure the interface before you can use this command. • Take Interface Out Of Service Takes the in-service configured interface to out- of-service status. You must use this command first before using the Delete All Interfaces command. • Configure Interface Configures the applied ATM IMA Interface. • View IMA Group Sta- tistics Displays statistics for all interfaces configured for IMA. • Go Back to Channel Config Redisplays the IMA Virtual Group Channel Configuration window. Command Function Table 3-3. Field Values for the DS1 IMA Group Configuration Window Field Name Values Description Minimum Tx Links Range: 1–6 Minimum number of transmit links required to be active for the IMA group to be in the Up state. Minimum Rx Links Range: 1–6 Minimum number of receive links required to be active for the IMA group to be in the Up state. Near-end Tx Clock Default: ctc Transmit clocking mode used by the near-end IMA group. The Common Transmit Clock (CTC) mode corresponds when the transmit clock of all IMA links are derived from the same source. You must set up the underlying clock configuration to ensure operation in the selected mode. itc The Independent Transmit Clock (ITC) mode corresponds when there is at least one IMA link whose transmit clock is derived from a source different than at least one other link transmit clock. You must set up the underlying clock con- figuration to ensure operation in the selected mode. Tx IMA Id Range: 0–255 The IMA identifier currently used by the far-end IMA func- tion. Tx Frame Length m128 (default) m32, m64, m256 The frame length to be used by the IMA group in the trans- mit direction. This can be set only when the IMA group is startup.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Configuring the Module 5 6 Select the Apply IMA Group Configuration command and press Enter. 7 Select the Configure Interface command and press Enter. The selected interface type window displays. See Chapter 5, "Configuring the Interfaces Using the AC Console," for instructions. Link Delay Diff Default: 25 Range: 1–200 The maximum number of milliseconds of delay differential among the links that will be tolerated on this surface. Compatibility Mode Default: No, Yes Used to indicate interoperability mode to the I/O module in terms of reporting the link status at the correct location in the IMA Control Protocol (ICP)cell. Alpha Value Default: 2 Range: 1–2 Indicates the alpha value, measured in cells,, measured in cells, used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the E1 and T11 IMA will go into an error state. Beta Value Default: 2 Range: 1–5 Indicates the beta value, measured in cells, used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the E1 IMA will go into an error state. Gamma Value Default: 1 Range: 1–5 Indicates the gamma value used to specify the number of consecutive valid ICP cells to be detected before moving from the IMA PRESYNC state to the IMA SYNC state. Ports In The Group Range: 1–6 Displays the ports which are configured to be in the current IMA group. If this field is blank, it shows that no ports in this group. Ports Available Range: 1 2 3 4 5 6 Displays the ports that are available to be included in this group. The sum of ports in "Ports in Group" and "Ports Available" will be 1,2,3,4,5,6, which means that any port which is available is not already in the group. If 1 2 3 4 5 6 is dis- played, it means that all 6 ports are available to be included in this particular group. Interface Type Default: Unconfigured The interface for this channel is not configured. AtmUni30 This interface is configured for ATM UNI 3.0 interface. AtmUni31 This interface is configured for ATM UNI 3.1 interface. IispUser This interface is configured for ATM IispUser interface. IispNetwork This interface is configured for ATM IispNetwork interface. AtmPnni1_0 This interface is configured for ATM PNNI 1.0 interface. Table 3-3. Field Values for the DS1 IMA Group Configuration Window Field Name Values Description

Chapter 3 Configuring Ports and Channels Using the Console

Saving Equipment Configuration and Logging Off 3-18 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 8 Repeat steps 1–7 under “Setting Up DS1 IMA Groups” on page 3-13 for the remaining two IMA groups, as needed. All six physical ports may belong to one group. End Saving Equipment Configuration and Logging Off After configuring the module ports and channels, the interface types for each port and channel, and the connections, you must save the configuration permanently, before you exit the current session for the PSAX system console interface. It is recommended that you save your configuration frequently, after you configure each module, and then again after configuring the connections of each type you will have in your system. Finally, before you exit your current session, be sure you save your configuration for the last time by performing the steps in the following procedure. ! CAUTION: If your system or location loses power or your current session ends abnormally while you are in the process of configuring the system, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows. Begin Saving the PSAX System Values 1 Press Ctrl+G while on any window to display the Console Interface Main Menu window. 2 Select the Save Configuration command and press Enter (or press Ctrl+A). Wait a few seconds while the system writes the values permanently to the Multiservice Media Gateway system database. The system displays the following message while it is executing this command: Saving the equipment and connection information When the command is completed, the system displays the following message: T-SaveConfiguration: saveConfigurationReasonCode=All- OK You can now safely exit the current session. Note: In PSAX systems with redundant CPU2 modules, the backup CPU2 module reboots every time you save the configuration on the primary CPU2 module. This event is a function of the SVC

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 3 Configuring Ports and Channels Using the Console Saving Equipment Configuration and Logging Off retention feature and the result of saving the configuration changes you have made. 3 Select the Leave Console Interface command and press Enter. You are now logged off the PSAX Multiservice Media Gateway system console interface. End

Chapter 3 Configuring Ports and Channels Using the Console

Saving Equipment Configuration and Logging Off 3-20 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 255-700-166 4-1 4 Configuring Ports and Channels Using the AQueView® System Overview of This Chapter This chapter describes how to set the values for the port and channel configuration for the 6-Port DS1 IMA module using the AQueView® Element Management System (EMS). Before You Begin Be sure to complete the following actions first before configuring the 6-Port DS1 IMA module: • Set the values to configure your basic system (see the appropriate AQueView® Element Management System User Guide) • Set the values to configure the Stratum 3–4 module (see the appropriate AQueView® Element Management System User Guide) When configuring the 6-Port DS1 IMA module using the AQueView® EMS, display-only fields are gray. The configuration of the 6-Port DS1 IMA module involves the following major tasks: 1. Each port must be configured with the IMA interface, and that IMA interface must be brought into service. 2. Each IMA group must be established. 3. Each IMA group must be configured with an ATM interface (IISP, UNI, or PNNI). ! CAUTION: When using a DSP2A, DSP2B, DSP2C, or DSP2D Voice Server module and an Enhanced DS1 or E1 module with a PBX and/or key telephone system, the Multiservice Media Gateway system and your equipment should use a common chassis ground connection to avoid ground current loops, which could affect voice quality. Loopback Configuration Options To aid network troubleshooting and testing, loopback capability is provided for the 6-Port DS1 IMA module. The loopback option on the module port and channel configuration window for the module enables you to verify the integrity of a port by transmitting a received signal back to the source. Selecting a loopback option is described in Chapter 3.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-2 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 If configuring a pair of 6-Port DS1 IMA module in the primary and standby setup, the desired loopback option must be configured by the user on both the primary and standby modules prior to bringing the pair into service. This parameter is applied on a port-by-port basis on both the primary and standby modules. If the line loop or local loop configuration is transferred from port A on the primary module to port B on the standby module, the port parameter does not transfer; it must be pre-configured on the standby by the user. The following modules support line loop or local loop only if the standby is preconfigured on a port-by-port basis: • 1-Port OC-3c 1+1 APS Multimode and Single-Mode modules • 1-Port STM-1 1+1 MSP Multimode and Single-Mode modules • 1-Port OC-12c/STM-4c 1+1 APS/MSP Multimode and Single-Mode modules Using the Right-Click Menu You can perform various functions in the AQueView system by clicking the right mouse button. This section describes the right-click menu options you can use in the various windows in the AQueView system when configuring ports and channels. Configuring Ports and Channels Figure 4-1. Sample Port Configuration (Displaying Right-Click Menu)

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Context-Sensitive Help If you right-click on a field in a port and channel configuration window, a description of that field appears (see Figure 4-3): Figure 4-2. Sample Channel Configuration (Displaying Right-Click Menu) Table 4-1. Descriptions of the Port and Channel Configuration Right-Click Menu Options Option Function Configure Opens the port and channel configuration window of a module. Bring All Inter- faces Into Service Sets all interfaces on a port administratively into service. Take All Inter- faces Out of Ser- vice Takes all interfaces on a port administratively out of ser- vice. Delete All Inter- faces Deletes all interfaces. All interfaces to be deleted must be administratively out of service first. Channel Selec- tion Opens the appropriate channel configuration window for the selected channel.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-4 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Configuring the 6- Port DS1 IMA Module You must first configure the 6-Port DS1 IMA module before you can set up connection provisioning. To access the port and channel configuration functions in the AQueView system, do the following: 1. Log in to the AQueView system as a user with Administrator or Configurator access privileges. 2. From the Device List or the Open Device window (press Ctrl+D or Ctrl+O), open the PSAX device that contains the module on which you want to configure a port or channel. The Front Panel view and Device Tree for that PSAX device will appear (see Figure 4-4). Figure 4-3. Sample of Context-Sensitive Help (Displayed on a Port and Channel Configuration Window)

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Configuring the Module IMA Port Configuration Perform the steps in the following procedure to configure ports on the 6-Port DS1 IMA module. Begin Configuring the Ports 1 Do one of the following to open the Port and Channel Configuration window: ~ In the Front Panel, click the left button twice on the port to be configured or displayed (see Figure 4-5). ~ In the Front Panel, double-click the right button on the port and a menu appears. Click Configure in the menu that appears. ~ In the Device Tree, double-click the desired port symbol or identifier with the left mouse button. Figure 4-4. Provisioning Window (Displaying a Typical Setup)

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-6 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 ~ In the Device Tree, select a port then click the right mouse button on the Device Tree and a menu appears. Click Configure. The DS1 IMA Port and Channel Configuration window appears (see Figure 4-6). The DS1 IMA Port and Channel Configuration window contains: ~ The Port Configuration page allows you to do the following: Figure 4-5. Front Panel View of the DS1 IMA Module Figure 4-6. DS1 IMA Port and Channel Configuration Window

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu • Select and apply port settings • View port statistics, which display line errors and coding violations • View line status ~ The Channel Configuration page allows you to do the following: • Select and apply an interface • Open the Interface Configuration window to configure the interface Note: All interfaces must be out of service before changes can be made to the port settings; otherwise, the Apply button will appear to be ghosted. Buttons The buttons in this window have the following functions: Field Descriptions 2 Select the values for the fields in this window as described in Table 4-2. Button Function • Close Closes this window. • Apply Applies the configuration field value you set. • Reset Resets the fields to the last set of applied values. • Copy.. Copies a port configuration to a range of ports. • Update Updates the information in the fields. • Clear Removes the values in the Port Statistics panel and resets them to 0. • Poll+ or Poll- Poll+ initiates the continuous update of statistics. Poll- suspends polling. Table 4-2. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description Line Type Default: Esf Extended Super Frame DS1 format. (display only) D4 D4 format. Channels are assigned sequentially. Line Coding (display only) Default: B8ZS Bipolar with 8 zero substitution. Use of a specified pattern of normal bits and bipolar violations to replace sequence of 8 zero bits. Ami Alterable mark inversion. Indicates zero code suppression. Loopback Con- fig Default: NoLoop The port is not in loopback state.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-8 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 LocalLoop The signal is received from another module in the chassis, sent through the module circuitry, including the segmen- tation and reassembly (SAR) function, and the chassis backplane to the origi- nating module. PayloadLoop The received signal is sent through the framing chip on the module, but not the SAR circuitry, and then back out to the originating point. The data link is regenerated. LineLoop The received signal is sent through the receiver and the line driver, and then back out to the originating point. Transmit Clock Default: LocalTiming Local clock source is used as the timing source. LoopTiming Recovered receive clock is used as the transmit clock Line Build Out Default: Up To 133 Feet Indicates the DS1 signal is designed to be valid from 0 to 133 feet Up To 266 Feet Indicates the DS1 signal is designed to be valid from 134 to 266 feet Up To 399 Feet Indicates the DS1 signal is designed to be valid from 267 to 399 feet Up To 533 Feet Indicates the DS1 signal is designed to be valid from 400 to 533 feet Up To 655 Feet Indicates the DS1 signal is designed to be valid from 534 to 655 feet negative7-5Db Indicates the T1 signal level range at which the DS1 is configured is negative 7.5 dB negative15Db Indicates the T1 signal level range at which the DS1 is configured is negative 15 dB negative22-5Db Indicates the T1 signal level range at which the DS1 is configured is negative 22.5 dB Table 4-2. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Line Status (display only) Indicates the line status of the interface: loopback, failure, received and transmitted alarm information. See the bit map tables for the 6-Port DS1 IMA module under the MIB object lineStatus in Appendix A, "SNMP Trap Messages" in any PacketStar™ Access Concentrator User’s Guide. NoAlarm (default) No alarm is present. RcvFarEndLOF Far-end loss of frame. FarEndLOF Near-end sending loss of frame indication. RcvAIS Far-end sending alarm indication signal. AIS Near-end sending alarm indication signal. LossOfFrame Near-end loss of frame. LossOfSignal Near-end loss of signal. LoopbackState Near-end is looped. T16AIS E1 TS16 AIS. Rcv FarEndLOMF Far-end sending TS16 LOMF. FarEndLOMF Near-end sending TS16 LOMF. RcvTestCode Near-end detects a test code. OtherFailure Any line status not defined here. RmtLoopback Far-end loopback. Interface Type (is displayed on the Channel Configuration page) Unconfigured This interface is not configured Ima This interface is configured as an IMA interface. Admin Status (display only) (displayed on the Channel Configuration page) Unconfigured The interface for the port is not config- ured. OutOfService The interface has not yet been brought into service, or in-service interface has been set to out of service with the Take Out of Service button. InService The interface has been brought into ser- vice with the Bring Into Service button. Table 4-2. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-10 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 3 Click Apply. End Copying a Port Configuration The Copy button on the Port and Channel Configuration window of each I/O module enables you to copy a port configuration to a range of ports. To copy a port configuration to a range of ports, perform the steps in the following procedure from the appropriate Port and Channel Configuration window. Begin Copying a Port Configuration to Multiple Ports 1 On the Port Configuration page, click Copy. The Copy Port Configuration window appears with the slot and port of the module you selected in the Start At: and Stop At: panels (see Figure 4-7). Oper Status (display only) (displayed on the Channel Configuration page) Unconfigured This channel is not operational because the interface is not configured. OutOfService Two types of problems cause this status. • A loss-of-signal condition exists due to any one of the following: ~ The module port is not physically connected to a cable. ~ The cable is not connected at the other end to a device. ~ The cable is broken. • A loss of frame or encoding exists due to a problem with the framing or encoding of the signal. For example, a repeater could corrupt the signal. InService The port is physically connected to a cable; the cable is conducting the signal; and the signal is being transmitted and received correctly. Table 4-2. Field Values for the DS1 IMA Port and Channel Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Buttons The buttons in this window have the following functions: 2 Select the range of slots and ports to which you wish the port configuration to be copied. 3 To copy the interface configuration of this module, click the box beside Copy interface configuration. 4 To overwrite the existing interface configuration of the destination ports, click the box beside Overwrite configured interfaces (this option is only available if Copy interface configuration is selected). Note: The Overwrite configured interfaces option is ghosted until you click the box beside Copy interface configuration. 5 Click Copy. The port configuration is copied to the range of ports you selected. End Channel Configuration Perform the steps in the following procedure to configure channels on the 6- Port DS1 IMA module. Begin Configuring the Channels 1 Click the Channel Configuration tab. The Channel Configuration page appears (see Figure 4-8). Figure 4-7. Sample Copy Port Configuration Window Button Function • Close Closes this window. • Copy Copies this interface to a range of channels.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-12 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Buttons The buttons in this window have the following functions: 2 In the Channel Configuration page, click the Interface Type field and select an ATM interface from the list. Click Apply to Selected. The appropriate Interface Configuration window appears. For information about configuring the interfaces, see Chapter 6, "Configuring the Interfaces Using the AQueView™ System.” 3 Select the values for this interface as described in Chapter 6. 4 To update the interface configuration display, click Update. 5 To activate the interface, click Bring Into Service. The value InService is displayed in the Administrative Status and Operational Status fields. 6 On the Channel Configuration window, click Apply to Selected. 7 Click the right mouse button in the list in the Channel Configuration window. A menu appears. Click Bring Into Service. Figure 4-8. Channel Configuration Page Button Function • Apply to Selected Applies the configuration field value you set . • Configure Virtual Channels Displays the IMA Virtual Channel Config- uration window appears (see Figure 4-9). • Close Closes this window.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu 8 Repeat this procedure to configure additional ports, as desired. 9 When finished configuring, click Close. End Viewing Port Statistics You can view the port statistics for the 6-Port DS1 IMA module on the Port Statistics panel of the DS1 IMA Port and Channel Configuration window (see Figure 4-6). Field Descriptions The field values for this window are described in Table 4-3. IMA Virtual Channels You can set up DS1 IMA virtual channels on the 6-Port DS1 IMA module. You can configure up to three IMA channels for each module, and each channel can contain up to six ports. Up to three channels can be configured on the virtual port (port 7). A group must have at least two, and up to six of the physical ports assigned to it. For example: Table 4-3. Data Field Descriptions of the DS1 IMA Port Statistics Window Field Names Description Errored Seconds A second with at least one of the foll- wing: ~ Path Code Violations ~ Controlled Slip events ~ A detected AIS defect ~ Presence of Bipolar Violations. Severely Errored Seconds A second with at least one of the fol- lowing: ~ 320 or more Path Code Violation Error events ~ Out of Frame defects ~ A detected AIS defect ~ A count of one-second intervals with Framing error events, an OOF defect, or a minimum of 1544 LCVs. Line Coding Violations A Bipolar Violation or Excessive Zeroes Error Event has occurred. Time Elapsed Time elapsed since last reset.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-14 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 ~ You can assign all six of the physical ports to channel 1 ~ You can assign ports 1, 3, 5 to channel 1, and ports 2, 4, and 6 to channel 2, and so on IMA Virtual Channel Configuration Perform the steps in the following procedure to configure virtual channels on the 6-Port DS1 IMA module. Virtual Channel Configuration Begin Setting the Values for the DS1 IMA Virtual Channels 1 Do one of the following to open the Port and Channel Configuration window: ~ In the Front Panel, double-click the left mouse button on the port to be configured or displayed. ~ In the Front Panel, double-click the right button on the port and a menu appears. Click Configure in the menu that appears. ~ In the Device Tree, double-click the desired port symbol or identifier with the left mouse button. ~ In the Device Tree, select a port then click the right mouse button on the Device Tree and a menu appears. Click Configure. 2 Click the Channel Configuration tab. 3 Click Configure Virtual Channels The IMA Virtual Channel Configuration window appears (see Figure 4-9).

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Field Descriptions 4 Select the values for the fields in this window as described in Table 4-4. Figure 4-9. IMA Virtual Channel Configuration Window Table 4-4. Field Values for the IMA Virtual Channel Configuration Page Field Name Values Description Interface Type Default: Unconfigured The interface for this channel is not configured. AtmUni3_0 This interface is configured for ATM UNI 3.0 interface. AtmUni3_1 This interface is configured for ATM UNI 3.1 interface. IispUser This interface is configured for ATM IISP User interface. IispNetwork This interface is configured for ATM IISP Network interface. AtmPnni1_0 This interface is configured for ATM PNNI 1.0 interface.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-16 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Port Group Range: 1–6 Displays the ports which are configured to be in the current IMA virtual chan- nel. If this field is blank, it shows that no port groups are assigned to this vir- tual channel. Port groups that are available are high- lighted, and ports that are unavailable are ghosted. Minimum Tx Links Range: 1–6 Minimum number of transmit links required to be active for the IMA group to be in the Up state. Minimum Rx Links Range: 1–6 Minimum number of receive links required to be active for the IMA group to be in the Up state. Near-end Tx Clock Default: ctc Transmit clocking mode used by the near-end IMA group. The Common Transmit Clock (CTC) mode corre- sponds when the transmit clock of all IMA links are derived from the same source. You must set up the underlying clock configuration to ensure operation in the selected mode. itc The Independent Transmit Clock (ITC) mode corresponds when there is at least one IMA link whose transmit clock is derived from a source different than at least one other link transmit clock. You must set up the underlying clock con- figuration to ensure operation in the selected mode. Tx IMA ID Range: 0–255 The IMA identifier currently used by the far-end IMA function. Tx Frame Length M128 (default) M32, M64, M256 The frame length to be used by the IMA group in the transmit direction. This can be set only when the IMA group is startup. Link Delay Diff (ms) Default: 25 Range: 1–200 The maximum number of milliseconds of delay differential among the links that will be tolerated on this surface. Compatibility Mode Default: No, Yes Used to indicate interoperability mode to the I/O module in terms of reporting the link status at the correct location in the IMA Control Protocol (ICP)cell. Table 4-4. Field Values for the IMA Virtual Channel Configuration Page Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu 5 Click Apply to Selected > Close. 6 Select the channel to be configured in the IMA Virtual Channel Configuration window. 7 In the Channel Configuration page, either click the arrow in the Interface Type field (in the middle of the window), or double-click the channel, and select an ATM interface from the list (ATM PNNI, ATM UNI, or ATM IISP). Click Apply to Selected. Note: The interface cannot be configured until after the port groups have been selected and applied to the virtual channel. Note: You can double-click in the channel in the list to select a new interface only when an interface is not currently selected for that channel. If an interface is applied for a channel and you double- click on it in the list, the Interface Configuration window appears. 8 Click the right mouse button in the list in the Channel Configuration window and a menu appears. Click Bring Into Service. 9 Repeat this procedure to configure additional virtual channels. 10 Click Close. End Alpha Value (cells) Default: 2 Range: 1–2 Indicates the alpha value, measured in cells,, measured in cells, used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the E1 and T11 IMA will go into an error state. Beta Value (cells) Default: 2 Range: 1–5 Indicates the beta value, measured in cells, used to specify the number of con- secutive errored ICP cells to be detected before moving to the IMA HUNT state. The smaller the value, the faster the E1 IMA will go into an error state. Gamma Value Default: 1 Range: 1–5 Indicates the gamma value used to specify the number of consecutive valid ICP cells to be detected before moving from the IMA PRESYNC state to the IMA SYNC state. Table 4-4. Field Values for the IMA Virtual Channel Configuration Page Field Name Values Description

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-18 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Viewing Channel Details Perform the steps in the following procedure to view channel details for the 6-Port DS1 IMA module. IMA Channel Details On the IMA Virtual Channel Configuration window, click the Channel 1 Details tab (or whichever channel number of which you wish to view statistics). The Channel 1 Details page appears (see Figure 4-10). Buttons The buttons in this window have the following functions: Figure 4-10. DS1 IMA Channel Details Window Button Function • Update Updates the information in the fields. • Clear Removes the values in the Port Statistics panel and resets them to 0.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Field Descriptions The field values for this window are described in Table 4-5. • Poll- or Poll+ Poll+ initiates the continuous update of statistics. Poll- suspends polling. • Close Closes this window. Button Function Table 4-5. Field Values for the IMA Channel Details Page Field Name Values Description Far-end Tx Clock (display only) Default: Ctc Itc Transmit clocking mode used by the far- end IMA group. There are two possible modes: the Common Transmit Clock (CTC) and the Independent Transmit Clock (ITC). The CTC mode corresponds to the case when the transmit clock of all IMA links are derived from the same source. The ITC configuration corresponds to the case where there is at least one IMA link whose transmit clock is derived from a source different than at least another link transmit clock. Rx IMA ID (display only) Default: 0 Range: 0-255 The IMA ID currently in use by the far- end IMA function. Rx Frame Length (display only) Default: M32 m64(, m128, m256 Value of IMA frame length as received from remote IMA function. Least Delay Link (display only) Default: Port 0 The interface index of the link config- ured in the IMA group which has the smallest link propagation delay. This value has meaning only if at least 1 link has been configured in the IMA group. Max Delay Diff (display only) Default: 1 Maximum delay differential. The maxi- mum number of milliseconds of delay differential among the links that will be tolerated on this interface. Near-end State (display only) The current operational state of the near-end IMA group state machine. Default: NotConfigured The group does not exist. StartUp This end is in start-up and is waiting to receive the indications that the Far-end is in start-up.

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-20 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 StartUpAck When both groups start up, they move through this transitional state to the Insufficient-Links state.While in this state, indications from the near-end that it is in start-up are ignored. CfgAbt Configuration aborted. This state is entered when the near-end tries to use the following unacceptable configura- tion parameters. • UnsupportedM: Unsupported value of M • CfgAbtInc Symmetry: Incompatible group symmetry • CfgAbtOther: Other reasons Insufficient Links This state implies that the group has accepted the near-end group parame- ters and that the near-end has also accepted its own group parameters, and does not have sufficient links to move into the Operational state. This state is excited whe “sufficient links” can be moved into the Active state. Blocked The group is blocked (e.g., inhibiterd by the UM). The group can be blocked for maintenance purposes while sufficient links are Active in both directions. The group is not inhibited and has suffi- cient links in both the Tx and Rx directions. The IMA interface has now the capability to receive ATM layer cells and pass them from the IMA sublayer to the ATM layer. Operational The group is operational. Far-end State (display only) Default: NotConfigured The current operational state of the near-end IMA group state machine. The group does not exist. StartUp This end is in start-up and is waiting to receive the indications that the near- end is in start-up. StartUpAck When both groups start up, they move through this transitional state to the Insufficient-Links state.While in this state, indications from the near-end that it is in start-up are ignored. Table 4-5. Field Values for the IMA Channel Details Page Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu CfgAbt Configuration aborted. This state is entered when the near-end tries to use the following unacceptable configura- tion parameters . • UnsupportedM: Unsupported value of M • CfgAbtInc Symmetry: Incompatible group symmetry • CfgAbtOther: Other reasons Insufficient Links This state implies that the group has accepted the far-end group parameters and that the far-end has also accepted its own group parameters, and does not have sufficient links to move into the Operational state. This state is excited whe “sufficient links” can be moved into the Active state. Blocked The group is blocked (e.g., inhibited by the UM). The group can be blocked for maintenance purposes while sufficient links are Active in both directions. The group is not inhibited and has suffi- cient links in both the Tx and Rx directions. The IMA interface has now the capability to receive ATM layer cells and pass them from the IMA sublayer to the ATM layer. Operational The group is operational. Table 4-5. Field Values for the IMA Channel Details Page Field Name Values Description

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-22 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Failure Status (display only) The current failure status of the IMA group (the reason why the group state machine is in the down state). See the operational state values for Near-end State and Far-end State above. Default: NoFailure StartUpNe StartUpFe InvalidM ValueNe InvalidM ValueFe Failed AssymetricNe Failed AssymetricFe InsuffLinksNe InsuffLinksFe BlockedNe BlockedFe OtherFailure Group Symmetry (display only) Symmetry of the IMA group. Default: Sym- Operation Symmetric operation. AsymOperation Asymmetric operation. AsymConfigu- ration Asymmetric configuration. IMA Group Statistics panel (display only): Near-end Fail- ures Default: 0 Count of near end Rx failure alarm con- ditions has been entered on this link. Far-end Fail- ures Default: 0 Count of far end Rx failure alarm condi- tions has been entered on this link. Number of Active Tx Links Default: 0 Range 1-32 Minimum number of transmit links required to be Active for the IMA group to be in the Up state. Table 4-5. Field Values for the IMA Channel Details Page Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 4 Configuring Ports and Channels Using the AQueView® System Using the Right-Click Menu Number of Active Rx Links Default: 0 Range 1–32 Minimum number of receive links required to be Active for the IMA group to be in the Up state. Time Elapsed Default: 0 days 00:00:00 Time elapsed, in days, hours, minutes, and seconds, since last reset. Table 4-5. Field Values for the IMA Channel Details Page Field Name Values Description

Chapter 4 Configuring Ports and Channels Using the AQueView® System

Using the Right-Click Menu 4-24 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 255-700-166 5-1 5 Configuring the Interfaces Using the Console Overview of This Chapter This chapter provides instructions for configuring the 6-Port DS1 IMA module for the ATM IMA interface. Before you can set interface configuration values, you must select an interface type value other than Unconfigured in the Interface Type field on the DS1 IMA Port and Channel Configuration window. Note: Ports 1-6 of the 6-Port DS1 IMA module can be configured for native DS1 ATM interfaces and for the ATM IMA interface. However, when you configure a group (channel), you may configure it for one of the following interfaces: ATM IISP User, ATM IISP Network, ATM UNI 3.0, ATM UNI 3.1, ATM UNI 4.0 or ATM PNNI 1.0. For a matrix of modules and supporting interface types, see the Interface Types by I/O Module Types Table in the Reference Tables appendix of your PacketStar® PSAX User Guide. Errors in Applying Interfaces to Ports An error can occur when you apply an interface to a port or channel. If an error condition occurs, the Multiservice Media Gateway sends an SNMP trap that usually appears in the console Trap Log Display (accessible from the Console Interface Main Menu window). The list below includes the most common interface errors that cause the PSAX system to display a message. (See the appendix, “SNMP Trap Messages,” for more information about the SNMP traps related to interface errors). • Entering values into fields that are outside of the configurable range of values • Attempting to configure an interface for a port or channel that has already been configured • Attempting to configure an interface that is already in service (must be out of service to be configured or change field values) • Entering field values that are not recognized by the PSAX system software

Chapter 5 Configuring the Interfaces Using the Console

ATM IMA Interface 5-2 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 ATM IMA Interface This section provides instructions for configuring an I/O module for the ATM Inverse Multiplexing over ATM (IMA) interface. You may configure the following I/O modules for the ATM IMA interface: • 6-Port DS1 IMA module • 1-Port DS3 IMA module • 6-Port E1 IMA module Automatic Use of IMA Links In an IMA group, if one link is broken, the group can be configured to automatically use the other links. For example, if an IMA group has three DS1 links and one of the links fails, although the throughput will drop from 4.5 Mbps to 3.0 Mbps, the IMA group continues to work. If the slowest link fails, there will be some cell loss on CBR connections as the other links speed up their cell rate to eliminate excess delay, due to their buffering of cells. IMA Configuration Considerations Note: If your PSAX unit will be interoperating with a device that has implemented ATM Forum IMA ATM Specification Version 1.0 such that its equipment incorrectly reports link states to the far- end of an IMA connection, you must configure IMA groups with the compatibility mode turned on. This also causes the PSAX unit to correctly report link states and interoperate with your ATM Forum IMA ATM Specification Version 1.0 equipment. The following is a list of operations considerations for the IMA interface: • Once an IMA group has been deleted, its status is displayed as "Insufficient-Links." • Links may not be added or removed from a group that is configured. You must delete any existing interfaces applied to the group before adding or removing links. • Operational Status refers to IMA group status, which can be viewed in the port and channel configuration window. ~ You can restart an IMA group by taking it administratively out of service and then bringing it back into service. ~ In order to change any group configuration parameters, the group must be completely unconfigured. ~ There may be difficulties if the IMA group is configured for symetric operation but has asymetric link delays. For example, one end may consider links A, B, and C to have problems, while the other end considers D, E, and F to have problems. ~ Four configurable transmit frame lengths are provided: 32, 64, 128, 256 cells. One ICP (IMA communication protocol) cell is sent over each link once per IMA frame. If you select a larger frame length,

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM IMA Interface there will be less overhead. If you select a smaller frame length, the IMA group has better response in communications with the far end, resulting in faster error detection and recovery. The IMA specification only requires equipment to support a frame length of 128. If a frame length other than 128 is configured and the far-end is connected to equipment that doesn’t support it, the far-end group enters the config- abort state. ~ The IMA identifier (ID) is an 8-bit (0-255) identifier for this IMA group. There is no significance to any particular values of IMA IDs. Since the IMA ID is used to identify a group to the far-end, pick a unique value instead of leaving it as the default of 0. Accessing the ATM IMA Interface If you selected the value AtmIma as the interface type, the ATM IMA Interface Configuration window (see Figure 5-1) is displayed. Commands The commands in this window have the following functions: Figure 5-1. ATM IMA Interface Configuration Window

Chapter 5 Configuring the Interfaces Using the Console

ATM IMA Interface 5-4 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 ATM IMA Values Descriptions of the values for the fields on this window are described in Table 5-1. Command Function • Update Display Refreshes the values in the Link States and the Defects fields • Bring Interface Into Service (is displayed when the [Admin Sta- tus] field is OutOfSer- vice) Brings an out-of-service configured interface into service. The value InService is displayed in the [Admin Status] field. An asterisk is displayed beside all the configured channels indicating that they are in service. Note: You must first configure the interface before you can use this command. • Take Interface Out of Service (is displayed when the [Admin Status] field is InSer- vice) Takes the in-service configured interface out of service. The displayed asterisk is removed from all configured channels indicating that they are out of service. Note: You must use this command first before using the Delete Interface and Return command. • Delete Interface and Return Deletes an out-of-service interface and redisplays the ATM IMA Configuration window. Note: You must first take interface out of service (using the Take Interface Out of Service command) before you can use this command. • Continuous Update Updates the values in the fields every second. • Reset Statistics Removes the values in the Interface Statistics fields and resets them to 0. • Go Back to Port Configuration Redisplays the Port and Channel Configuration window for the module you are configuring. Table 5-1. Field Values for the ATM IMA Interface Configuration Window Field Name Values Description [Oper Status] (display only) In service Indicates that the interface is operational. Out of service Indicates that the interface is not operational. [Admin Status] (display only) InService Indicates that the interface is in service. OutOfService Indicates that the interface is not in service.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM IMA Interface Link States panel (display only): [Near- end Tx], [Far-end Tx], [Near-end Rx], [Far- end Rx] Defects panel (display only): [Near-end Rx], [Far- end Rx] NotInGroup Interface is not assigned to a group. UnusableNo- Reason Does not work; non-specific reason. Unusable Fault Local failure status of a link belonging to an IMA group (not currently supported.) The PSAX device does not generate this con- dition, but may report such a condition gener- ated by the far end of an IMA connection. Unusable Misconnected An IMA link is not corrected to the proper end. (The PSAX device does not currently generate this condition, but the PSAX device reports this condition to the user if the far-end reports it to the PSAX device.) For example, when an IMA group is estab- lished, the links immediately discover which device they are connecting to on the far end. If cables are then removed and plugged back in differently, then the equipment may signify that it is misconnected. Unusable Inhib- ited This is an administrative mechanism for tak- ing an IMA link out of service. When in this state, it is unknown whether there are any physical problems with the link. Unusable Failed Check the defect value displayed. Usable There are no local reasons why this link is not active. The only thing preventing it from being active is the far-end state (for example, a transmitter cannot be active and send real data until the far-end receiver is ready to accept that data). Active Interface in use. NoDefect No link defects. Link failure Physical failure/loss of signal. LIF Persistent loss of IMA frame. LODS Link out of delay synchronization. Interface Statistics panel (display only) [IMA Violations] Count of errored, invalid or missing cells dur- ing non-SES-IMA condition. [OIF Anomalies] Count of OIF anomalies during non-SES-IMA conditions. [Near-end Tx Failures] Count of near end Tx failure alarm conditions has been entered on this link. Table 5-1. Field Values for the ATM IMA Interface Configuration Window Field Name Values Description

Chapter 5 Configuring the Interfaces Using the Console

Interim Interswitch Signaling Protocol (IISP) Interface 5-6 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Activating the IMA Interface To activate the interface on the ATM IMA Interface Configuration Window, select the Bring Interface Into Service command and press Enter. Interim Interswitch Signaling Protocol (IISP) Interface Interim Interswitch Signaling Protocol (IISP), formerly known as PNNI Phase 0, was introduced as an interim standard, pending completion of the PNNI Phase 1. Building on ATM UNI 3.0 and ATM UNI 3.1, it uses static routing tables established by the network administrator to route connections around link failures. The IISP interface requires the default range of values 0–255 for the virtual path identifier (VPI) and 32–255 for the virtual channel identifier (VCI) to accept and establish calls. This value is set on the ATM IISP Interface Configuration window. Each connection using the IISP interface is configurable as either the user side or the network side. Optimizing SVC Call Performance The service-specific connection-oriented protocol (SSCOP) field is set on these interface configuration windows: ATM IISP network or IISP user, ATM UNI 3.0 or UNI 3.1, or ATM PNNI 1.0. Note: These settings are suggested for connecting to a Multiservice Media Gateway from a remote site only. The Multiservice Media Gateway configures these settings internally in its own ATM switch. When there are unacknowledged protocol data units (PDUs), the MaxPD field on the remote end peer (such as the NavisCore™ CBX 500™) shows the [Near-end Rx Failures] Count of near end Rx failure alarm conditions has been entered on this link. [Far-end Tx Failures] Count of far end transmit failure alarm condi- tions has been entered on this link. [Far-end Rx Failures] Count of far end receive failure alarm condi- tions has been entered on this link. [Tx Stuffs] Count of stuff events inserted in the transmit direction on this link. [Rx Stuffs] Count of stuff events received in receive direction on this link. [Time Elapsed] Time elapsed since last reset. Table 5-1. Field Values for the ATM IMA Interface Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console Interim Interswitch Signaling Protocol (IISP) Interface maximum number of SSCOP transmitted since the last PSAX polling of the peer. To optimize call performance, the SSCOP Rx Window Size field of the local ATM interface should be less than the maximum value displayed in the MaxPD credit window at the remote end of the ATM interface. Otherwise, the rate at which switched calls can be set and released may be degraded. On the ATM IISP Interface Configuration window, the maximum credit window (the SSCOP Rx Window Size field) is configurable for a value up to 32 for all ATM interfaces on the Multiservice Media Gateway. The interfaces of the ATM switches that are connected to an Multiservice Media Gateway should be configured to the same values. This results in 100% call completion at a call setup rate of 60 calls per second using even distribution. If these values are not configured in this way, calls will be set up at a rate of less than 60 calls per second. Note: Various SSCOP parameter settings determine the maximum credit window. As a result, you may not be able to directly use these settings. Configuring the ATM IISP Interface When you select the value IispUser or IispNetwork as the interface type on a module port and channel configuration window associated with one of the modules listed at the beginning of this chapter, the ATM IISP Interface Configuration window (see Figure 5-2) appears. Figure 5-2. ATM IISP Interface Configuration Window

Chapter 5 Configuring the Interfaces Using the Console

Interim Interswitch Signaling Protocol (IISP) Interface 5-8 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Commands The commands in this window have the following functions: To set values for the ATM IISP interface, perform the steps in the following procedure. Begin Setting the Values for the ATM IISP Interface 1 Select the values for the fields on this window from the values given in Table 5-2. Field Descriptions Table 5-2 lists the field values for the ATM IISP Interface Configuration window. Command Function • Apply Interface Config- uration Applies the configuration field value you set. • Reset Interface Display • Resets the fields to the last set of applied values. • Bring Interface Into Service (displays when the [Admin Status] field is OutOfService) Brings an out-of-service configured interface to in-service status. The value InService is displayed in the [Admin Status]field. You must first configure the interface before you can use this command. • Take Interface Out of Service (displays when the [Admin Status] field is InService) Takes an in-service configured interface to out-of-service status. The value OutOfService is displayed in the [Admin Status] field. Note: You must use this command first before using the Delete Interface and Return command. • Delete Interface and Return→ Deletes an out-of-service interface and redisplays the Port and Channel Configuration window for the module you are config- uring. Note: You must first take interface out of service (using the Take Interface Out of Service command) before you can use this command. • Continuous Update Continuously updates the information in the Interface Statistics fields every second. Select this command and press Enter to turn the continuous updating on and off as needed. • Reset Statistics Removes the values in the Interface Statistics fields and resets them to 0. • Go Back to Port Config- uration→ Redisplays the port and channel configuration window of the module you are configuring.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console Interim Interswitch Signaling Protocol (IISP) Interface Table 5-2. Field Values for the ATM IISP Interface Configuration Window Field Name Values Description [Oper Status] (display only) Indicates whether the interface is operational according to the Administrative Status below. InService The interface is operational. OutOfService The interface is not operational because some condition is preventing the port from being fully operational, such as a loss of signal to the port. [Admin Status] (display only) Indicates the Administrative Status of the interfaces; or what the interface(s) are configured as. InService The interface is in service. OutOfService The interface is not in service. Over Subscription Default: 10 Range: 1–100 The risk factor for this function. This factor indicates the fac- tor of oversubscription allowed for this interface. Note: For the maximum and minimum VPI/VCI values below, always enter or change the maximum value before the minimum value. Min SVC VPI Default: 0 Range: 0–255 The minimum VPI value in which signaling can occur. Note: Disable ATM signaling field if you want to use VPI 0. Max SVC VPI Default: 0 Range: 0–255 The maximum VPI in which signaling can occur. Note: Disable ATM signaling field if you want to use VPI 0. Min SVC VCI Default: 32 Range: 0–65535 The minimum VCI in which signaling can occur. Max SVC VCI Default: 255 Range: 0–65535 The maximum VCI in which signaling can occur. ATM Signaling Default: Disabled SVCs cannot be created on this interface. Note: VPI 0 is not available for use. Enabled SVCs can be created on this interface. Note: VPI 0 is available for use.

Chapter 5 Configuring the Interfaces Using the Console

Interim Interswitch Signaling Protocol (IISP) Interface 5-10 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 UPC Support Usage parameter control (policing) determines if traffic con- trol is performing to negotiated PCR, SCR, or MBS. This fea- ture is supported on these modules: • OC-12c/STM-4c MM/SM 1+1 APS/MSP • OC-3c 1+1 APS SM/MM • STM-1 1+1 MSP SM/MM • Channelized DS3-to-DS0 • High Density E1 • Medium Density DS1 Default: Disabled UPC Support is disabled. Note: If UPC Support is disabled, traffic policing cannot be supported on any VC. Enabled UPC Support is enabled, providing traffic policing support for all VCs. UBR Load Balancing Default: Disabled Balance UBR traffic load among parallel links. UBR Load Balancing is disabled. Note: Virtual interfaces do not support UBR Load Balancing. Enabled UBR Load Balancing is enabled. SSCOP Rx Wnd Size The service-specific connection-oriented protocol (SSCOP) layer. This window shows the total number of packets that must be acknowledged by the receiving side before more packets are sent from the transmitting side. Default: 32 Range: 8–256 On the receiving side, values must be equal to or greater than the values for the transmit side for fastest transmission rates. Traffic Shaping An input cell selection algorithm (leaky bucket) that smooths bursts of input traffic. Available on these modules only: STM-1 Multi-Mode and Single-Mode, OC-3c Multi-Mode and Single-Mode Default: Disabled Disables the feature. Enabled Note: Enables the feature. This feature must be enabled if using rate shaping prior to egress from an ATM trunk port on the OC-3c APS or the STM-1 MSP modules Interface Statistics Panel (display only) [Valid Cells Rcvd] Number of valid cells received since the statistics were last reset. [Errored Cells Rcvd] Number of errored cells received since the statistics were last reset. Table 5-2. Field Values for the ATM IISP Interface Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 2 To apply the interface configuration values, select the Apply Interface Configuration command and press Enter. 3 To activate the interface after you have applied the configuration values, select the Bring Interface Into Service command and press Enter. Note: The interface must have in-service status so that the PVCs and SVCs you will set up to use this interface will work. End ATM User-Network Interface 3.0, 3.1, and 4.0 Configuring the Interface When you select the value AtmUni3-0, AtmUni3-1, or AtmUni4-0 as the interface type on a module port and channel configuration window associated with one of the modules listed on the ATM UNI Interface Configuration window is displayed (see Figure 5-3). [Mismatched Cells Rcvd] Number of mismatched cells received since the statistics were last reset. [Valid Cells Sent] Number of valid cells sent since the statistics were last reset. [Null Cells Sent] Number of null cells sent since the statistics were last reset. [Time Elapsed] Time elasped since counter began running since the statistics were last reset. [Ingress Avail BW] (cps) (display only) Default: 0 This represents the total ingress and egress bandwidth avail- able for virtual interfaces. 0 will change to 353207 after Apply has been selected. As each new virtual interface is created, the amount of available bandwidth as indicated in this field will decrease. The value of this field ranges from 0–353207 after being brought in service. [Egress Avail BW] (cps) (display only) Default: 0 This represents the total ingress and egress bandwidth avail- able for virtual interfaces. 0 will change to 353207 after Apply has been selected. As each new virtual interface is created, the amount of available bandwidth as indicated in this field will decrease. The value of this field ranges from 0–353207 after being brought in service. Table 5-2. Field Values for the ATM IISP Interface Configuration Window Field Name Values Description

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-12 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Commands The commands in this window have the following functions: Figure 5-3. ATM UNI Interface Configuration Window Command Function • Apply Interface Config- uration Applies the configuration field value you set. • Reset Interface Display Resets the fields to the last set of applied values. • Bring Interface Into Service (displays when the [Admin Status] field is OutOfService) Brings an out-of-service configured interface to in-service status. The value InService is displayed in the [Admin Sta- tus] field. Note: You must first configure the interface before you can use this command. • Take Interface Out of Service (displays when the [Admin Status] field is InService) Takes an in-service configured interface to out-of-service status. The value OutOfService is displayed in the [Admin Status] field. Note: You must use this command first before using the Delete Interface and Return command. • Delete Interface and Return Deletes an out-of-service interface and redisplays the Port and Channel Configuration window for the module you are configuring. Note: You must first take the interface out of service (by selecting the Take Interface Out of Service command) before you can use this command.

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 Field Descriptions To set values for the ATM UNI interface, perform the steps in the following procedure. Begin Setting the Values for the ATM UNI Interface 1 Select the values for the fields on this window from the values given in Table 5-3. • ATM UNI Interface Statistics Displays the ATM UNI Interface Statistics window. • ILMI Configuration Displays the ATM UNI ILMI Configuration window. • ILMI Registered User Address Displays the ILMI Registered User Address Table. • ILMI Statistics Displays the ILMI Statistics window • Go Back to Port Config- uration Redisplays the port and channel configuration window of the module you are configuring. Command Function Table 5-3. Field Descriptions for the ATM UNI Interface Configuration Window Field Name Values Description Over Subscription Default: 10 Range: 1–100 The risk factor for this function. This factor indicates the level of oversubscription allowed by the system. Note: For the maximum and minimum VPI and VCI values below, always enter or change the maximum value before the minimum value. Min/Max SVC VPI The minimum and maximum VPI values that you can assign to an SVC on this interface. Note: Disable the ATM signaling field if you want to use VPI 0. Default: 0 Range: 0–255 Enter the maximum value after the slash and then enter the minimum value before the slash. Min/Max SVC VCI Min: 32 (default) Max: 255 (default) Range: 0–65535 The minimum and maximum VCI values that you can assign to an SVC on this interface. Enter the maximum value after the slash and then enter the minimum value before the slash. ATM Signaling Default: Disabled SVCs cannot be created on this interface. Note: VPI 0 is not available for use. Enabled SVCs can be created on this interface. Note: VPI 0 is available for use.

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-14 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Interface Type Default: Network Indicates that the NNI format for the cell headers will be used. Note: When you select this value, the Prefix field is displayed below the Interface Name field. User Indicates that the UNI format for the cell headers will be used. Note: When you select this value, the User Add field is displayed below the Interface Name field. Interface Name (Maximum string of 20 characters) A textual name of this interface. This interface must be uniquely named on this system to distinguish par- allel links with a neighboring system. If this inter- face does not have a textual name, the value of this object is a zero-length string. Prefix Default: 2020202020202 0202020202020 Range: 13-byte (18-hexadeci- mal digit begin- ning with 39, 45 or 47) Network prefix address displays when the value Net- work is selected in the Interface Type field. This address is used only for address registration proce- dure of ILMI. This field represents the first 13 bytes of the 20-byte NSAP address. The last 7 bytes are the user part of this address (User Add field). User Add Default: 2020202020202 0202020202020 Range: 13-byte (18-hexadeci- mal digit begin- ning with 39, 45 or 47) User address displays when the value User is selected in the Interface Type field. Neighbor System IP Default: 000.000.000.00 0 (IP address) This field is used for auto-discovery protocol. Dis- plays the IP address of the attached device for an ILMI-enabled interface, or the user-configured IP address for an ILMI-disabled interface. For an ILMI-enabled interface, any user-configured value overrides ILMI discovered values. Enter the IP address of the PSAX chassis (or other device) to which the physical connection is made using this interface. Neighbor Name Format: 20 alphanumeric characters This field is used for identifying network topology. Enter a descriptive name up to 20 characters in length for the PSAX chassis (or other device) to which the physical connection is made using this interface. Table 5-3. Field Descriptions for the ATM UNI Interface Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 UPC Support Usage parameter control (policing) determines if traffic control is performing to negotiated PCR, SCR, or MBS. This feature is supported on these modules: • OC-12c/STM-4c MM/SM 1+1 APS/MSP • OC-3c 1+1 APS SM/MM • STM-1 1+1 MSP SM/MM • Channelized DS3-to-DS0 • High Density E1 • Medium Density DS1 Default: Disabled UPC support is disabled. Note: If UPC Support is disabled, traffic policing cannot be supported on any VC. Enabled UPC support is enabled, providing traffic policing support for all VCs. UBR Load Balanc- ing Default: Disabled Unspecified bit rate (UBR) load balancing is disabled. Note: The virtual interface does not support UBR load balancing. Enabled UBR load balancing is enabled. SSCOP Rx Wnd Size The service-specific connection-oriented protocol (SSCOP) layer. This window shows the total number of packets that must be acknowledged by the receiv- ing side before more packets are sent from the trans- mitting side. Default: 32 Range: 8–256 On the receiving side, the window size for this value must be equal to or greater than the values for the transmitting side for fastest transmission rates. VI Support Virtual interfaces connect to a module’s physical ports and allow virtual channels (VCs) to be assigned to virtual trunks, each with its own priority queue. This option is available only for these modules: OC3-c APS, STM-1 MSP. Enabled Feature is enabled, providing bandwidth allocation restrictions. Note: In order to configure a virtual interface, you must select Enabled. Disabled VI support is disabled. [Admin Status] (dis- play only) InService Indicates that no conditions are preventing the port from being fully operational. OutOfService Indicates that some condition is preventing the port from being configured with an interface. Table 5-3. Field Descriptions for the ATM UNI Interface Configuration Window Field Name Values Description

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-16 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 2 To apply the interface configuration values, select the Apply Interface Configuration command and press Enter. End Viewing ATM UNI Interface Statistics On the ATM UNI Interface Configuration window (see Figure 5-3), select the ATM UNI Interface Statistics command and press Enter. The ATM UNI Interface Statistics window is displayed (see Figure 5-4). [Oper Status] (dis- play only) Unconfigured Indicates that this interface has not been configured. InService Indicates that the interface is operational. OutOfService Indicates that the interface is not operational. [Ingress Avail BW] (cps) (display only) Default: 0 This represents the total ingress bandwidth available for virtual interfaces. The value 0 changes to 353207 after you select the Apply command. As each new virtual interface is created, the amount of available bandwidth as indicated in this field decreases. [Egress Avail BW] (cps) (display only) Default: 0 This represents the total egress bandwidth available for virtual interfaces. The value 0 changes to 353207 after you select the Apply command. As each new virtual interface is created, the amount of available bandwidth as indicated in this field decreases. Traffic Shaping An input cell selection algorithm (leaky bucket) that smooths bursts of input traffic. Available on these modules: STM-1 Multi-Mode and Single-Mode, OC- 3c Multi-Mode and Single-Mode. Default: Disabled Disables the feature. Enabled Enables the feature. Note: Field must be set to enabled if using rate shaping on the OC-3c APS or the STM-1 MSP modules prior to egress from an ATM trunk port. Table 5-3. Field Descriptions for the ATM UNI Interface Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 Commands The commands on this window have the following functions: Field Descriptions The fields on this window are described in Table 5-4. Figure 5-4. ATM UNI Interface Statistics Window Command Function • Continuous Update Continuously updates all fields once every second. • Reset Statistics Resets statistics counters for this interface. • Go Back to previous screen –> Returns to the ATM UNI Interface Configuration window. Table 5-4. Field Values for the ATM UNI Interface StatisticsWindow Field Name Description [Valid Cells Rcvd] Number of valid cells received into interface side A dur- ing the amount of time shown in Time Elapsed field. [Errored Cells Rcvd] Number of errored cells received into interface side A during the amount of time shown in Time Elapsed field.

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-18 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Configuring ATM UNI ILMI For more information on ILMI, see Chapter 3 “System Features,” of the appropriate PacketStar® Multiservice Media Gateway User Guide. When you select the ILMI Configuration command on the ATM UNI Interface Configuration window (see Figure 5-3 on page 5-12), the ATM UNI ILMI Configuration window is displayed (see Figure 5-5). Commands The commands in this window have the following functions: [Mismatched Cells Rcvd] Number of mismatched cells received into interface side A during the amount of time shown in Time Elapsed field. [Valid Cells Sent] Number of valid cells transmitted out of interface side B during the amount of time shown in Time Elapsed field. [Null Cells Sent] Number of null cells transmitted out of interface side B during the amount of time shown inTime Elapsed field. NOTE: This parameter is not supported in the OC-12c/STM-4c SM/MM 1+1 APS/MSP modules. [Time Elapsed] Time elapsed since the last reset in h:mm:ss (hour: minute:seconds) format. Table 5-4. Field Values for the ATM UNI Interface StatisticsWindow Field Name Description Figure 5-5. ATM UNI ILMI Configuration Window

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 To set values for ILMI configuration, perform the steps in the following procedure. Begin Setting the Values for the ATM UNI ILMI Configuration Window Field Descriptions 1 Select the values for the fields on this window from the values given in Table 5-5. Command Function • Apply ILMI Configura- tion Applies the configuration field values you set. • Go Back to Interface Screen Redisplays the ATM UNI Interface Configuration window. Table 5-5. Field Values for the ATM UNI ILMI Configuration Window Field Name Values Description [ILMI Oper Sta- tus] (display only) InService Indicates that ILMI connectivity is operational. OutOfService Indicates that ILMI connectivity is not operational. ILMI Protocol Default: Disabled If you select Disabled, the other fields in this window will not take effect. Enabled Enables ILMI. Address Registration Default: Disabled Address registration can be enabled only if the ILMI Protocol field is enabled. Enabled Enables address registration. Connectivity Procedure Default: Disabled ILMI Connectivity Procedure is disabled. You must select Enabled if you want to also enable the Attach- ment Point Detection and Secure Link fields. Enabled ILMI Connectivity Procedure is enabled. Attachment Point Detection Default: Disabled Enabled Attachment Point Change Detection can be enabled only if Connectivity Procedure and ILMI Protocol fields are enabled. Enabled A query will be sent every 5 seconds to detect a change in the address. A response indicates that the user id and address information are the same. How- ever, if there is a change in the address, all calls will be cleared.

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-20 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 2 To apply the interface configuration values, select the Apply ILMI Configuration command and press Enter. 3 To go back to the ATM UNI Interface Configuration window, select the Go Back to Interface Screen command and press Enter. 4 To activate the interface after you have applied the configuration values, select the Bring Interface Into Service command and press Enter. Displaying Registered Addresses 5 Select the ILMI Registered User Address Table command and press Enter. Secure Link Default: Disabled ILMI Secure Link Procedure is disabled. It can be enabled only if Connectivity Procedure and Attach- ment Point Detection fields are enabled. Enabled ILMI Secure Link Procedure is enabled. If you do not receive a response, all calls are cleared, and you will be disconnected. [Auto Configu- ration] (display only) Default: Disabled The ability to automatically configure VPI and VCI is disabled. Enabled Automatically configures the VPI and VCI. Auto configuration can be enabled only if the ILMI Protocol field is enabled. [TimerT] (display only) Default: 5 Range: Varies Timer T in seconds. Used to poll when link is opera- tional. The value in this field in displayed as a 32-bit integer, and any number may appear. [TimerS] (display only) Default: 1 Range: Varies Timer S in seconds. Used to poll when link is not operational. The value in this field in displayed as a 32-bit integer, and any number may appear. [RetryK] (display only) Default: 4 Range: Varies Retry K in seconds. Indicates the number of timeouts before the link becomes non-operational. The value in this field in displayed as a 32-bit integer, and any number may appear. [ILMI VPI] (display only) Default: 0 This value does not change. VPI for the ILMI protocol channel in which VPI will run. [ILMI VCI] (display only) Default: 16 This value does not change. VCI for the ILMI protocol channel in which VCI will run. Table 5-5. Field Values for the ATM UNI ILMI Configuration Window Field Name Values Description

PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1

Release 7.0 Chapter 5 Configuring the Interfaces Using the Console ATM User-Network Interface 3.0, 3.1, and 4.0 The ILMI Registered User Address Table window is displayed (see Figure 5-6). Commands The commands in this window have the following functions: The NSAP Address (Hex) column displays the user’s registered addresses. The Org Scope column displays the scope of the registered addresses. If the scope is not set by the user, it will default to global (a value of 15). 6 To go back to the ATM UNI Interface Configuration window, select the Go Back to Interface Screen command and press Enter. Viewing ILMI Statistics To view ILMI configuration statistics, do the following: 7 Select the ILMI Statistics command and press Enter. The ILMI Statistics window is displayed (see Figure 5-7). Figure 5-6. ILMI Registered User Address Table Window Command Function • Find.. Atm Addr: . . • Finds the user’s ATM address. • Go Back to Interface Screen→ • Redisplays the ATM UNI Interface Configura- tion window.

Chapter 5 Configuring the Interfaces Using the Console

ATM User-Network Interface 3.0, 3.1, and 4.0 5-22 255-700-166 PacketStar® PSAX 6-Port DS1 IMA Module User Guide, Issue 1 Release 7.0 Commands The commands in this window have the following functions: Field Descriptions The fields in this window are described in Table 5-6. Figure 5-7. ILMI Statistics Window Command Function • Continuous Update Continuously updates the information in the fields every second. Select this command and press Enter to turn the continuous updating on and off as needed. • Reset Statistics Resets the statistics counters for the ILMI Statis- tics window. • Go Back to Interface Screen→ Redisplays the ATM UNI Interface Configuration window. Table 5-6. Field Descriptions for the ILMI Statistics Window Field Name Description [Link Resets] (display only) Number of times connectivity went down and then up again. [AttachPt Changed] (display only) Number of times attachment point change was detected.