Omron K3NR Operation Manual

Specifications

Brand: Omron
Category: Measuring Instruments
Model: K3NR (Operation Manual)
File Type: PDF
File Size: —
Pages: 148

Read Online

Read the Omron K3NR Operation Manual online using the built-in PDF viewer.

Text of the manual

OMRON products are manufactured for use according to proper procedures by a qualified operator

and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or dam- age to the product. DANGER Indicates information that, if not heeded, is likely to result in loss of life or serious injury. WARNING Indicates information that, if not heeded, could possibly result in loss of life or serious injury. Caution Indicates information that, if not heeded, could result in relatively serious or minor injury, dam- age to the product, or faulty operation. OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for any- thing else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc.  OMRON, 1998 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permis- sion of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the informa- tion contained in this publication.

TABLE OF CONTENTS

vii PRECAUTIONS xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Application Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Noise Prevention xiii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Features 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Front of the Meter 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Rear of the Meter 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Modes 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Communications Function 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 Setup 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Mounting 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Input Block 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Output Board 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 Operating Modes 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Rotational/Circumferential Speed: F1 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Absolute Ratio: F2 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Error Ratio: F3 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Rotational Difference: F4 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Flow Rate Ratio: F5 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Passing Time: F6 37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Pulse Counting: F7 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 Parameter Setting 45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Overview 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Setting Mode 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Protect Mode 88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 Operations in RUN Mode 99 . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Displaying and Changing Setting Values 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Displaying and Resetting of Maximum and Minimum Values (Operating Modes F1 to F6) 103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 External Input Signals 104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6 Useful Functions 107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Teaching Function 108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Output Test 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Maintenance Mode 113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TABLE OF CONTENTS

viii SECTION 7 BCD Output 115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Connectors 116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Timing Charts 119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 8 Troubleshooting 121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Items to Be Checked First 122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Display 122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendices A Specifications 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Estimated Frequency Calculation 129 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C List of Settings 131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Available Models 133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E Available Parameters 135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F Setting Examples 139 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index 141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History 145 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

About this Manual:

This manual describes the installation and operation of the K3NR Frequency/Rate Meter and includes the sections described below. Please read this manual carefully and be sure you understand the information provided before attempting to install and operate the K3NR. Section 1 describes the functions of the K3NR. The main components are also described. Section 2 provides instructions required for mounting and wiring the K3NR. Section 3 provides instructions for setting the parameters of the K3NR. Section 4 provides instructions for operating the K3NR in RUN mode. Section 5 provides information on the teaching function, output test, and maintenance mode. Section 6 provides information on the use of the K3NR with the BCD Output Board. Section 7 provides information for troubleshooting the K3NR The Appendices provide specifications, a list of settings, a list of standard models, and a list of available menu items. WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. !

This section provides precautions for using the K3NR Frequency/Rate Meter and related devices.

The information contained in this section is important for the safe and reliable application of the K3NR. You must read this section and understand the information contained before attempting to set up or operate the K3NR. 1 General Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Application Precautions xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Noise Prevention xiii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The user must operate the product according to the performance specifications

described in the operation manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement ma- chines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Be sure to read this manual before attempting to use the product and keep this manual close at hand for reference during operation. 2 Safety Precautions WARNING Never attempt to disassemble any Units while power is being supplied. Doing so may result in serious electrical shock or electrocution. WARNING Never touch any of the terminals while power is being supplied. Doing so may result in serious electrical shock or electrocution. 3 Application Precautions Observe the following precautions when using the product. • Always use the power supply voltage specified in the specifications. • Do not use the product in locations subject to flammable gases or combustible objects. • Be sure to confirm terminal names when wiring. • Be sure to tighten the screws on the terminal blocks. Observe the following precautions when mounting the product. • Mount the product on level surfaces. • Mount the product on a panel which has a thickness of 1 to 3.2 mm. Do not mount the product in the following places. • Locations subject to strong shock or vibration. • Locations subject to temperature or humidity exceeding the rated levels or where icing is liable to occur. • Locations subject to dust. • Locations subject to corrosive gases (particularly sulfuric gases or ammonium gases). • Locations subject to direct sunlight or outdoor conditions. • Locations near devices (high-frequency welders or high-frequency sewing machines) that produce high-frequency noise.

Provide the following countermeasures when using the product in an environ-

ment where the product is exposed to noise. • Countermeasures for protecting the product against high-frequency noise or abnormal voltages. Line filter Frequency/Rate Meter Power input Power input Signal input + – Frequency/Rate Meter • Countermeasures for protecting the product against inductive noise produced from the input line. 2-conductor shield wire + Frequency/Rate Meter –

This section describes the functions of the K3NR. The main components are also described. Refer to the remaining sections of

this manual for the operation of the K3NR and its menus in detail. 1-1 Features 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Front of the Meter 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Rear of the Meter 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Modes 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Communications Function 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The K3NR Frequency/Rate Meter displays desired values after converting input

pulses. The K3NR has the following functions. Operating mode Function 1 Displays rotational or circumferential speed of a single input. 2 to 5 Displays the calculation results of two rotational inputs. 6 Displays passing time calculated from the frequency and process length of a single input. 7 Counts and displays the number of pulses. Measurement The internal system clock counts the ON/OFF time (T) of sensor input or other input and automatically calculates the frequency. The number of revolutions is calculated from the result of the frequency multiplied by 60. Sensor input pulse ON/OFF time (T) = Frequency (f) = T 1 • Rotational speed (rpm) = f x 60 • Circumferential speed = Circumference x revolutions • Passing time = Length of processing/Circumferential speed • Pulse counting If there is any pulse input, the input will be automatically converted numerically and displayed. Prescaling The number of input pulses is converted into a desired value. Enables the K3NR to display the revolutions or rotational speed. It is necessary to multiply the number of pulses per revolution or circumference by a certain fac- tor. This factor is called the prescaling value. Example: Proximity Sensor K3NR rpm = f x 60 x a f: Input pulse frequency (number of pulses per second) a: Prescale value If there are five pulses per rotation, the accurate rotational speed can be calculated if a = 1/5 (– 0.2=2 x 10–1). Comparison output patterns can be selected from the standard, level, or zone output depending on the application. Refer to Comparative Output Patterns, page 80. Refer to Linear Output Range, page 83. BCD Output A digital data output format where every four binary bits is numerically equivalent to one decimal digit. Refer to Section 7 BCD Output. Refer to the Communications Manual. HOLD is an external input which is used to stop the A/D process and freeze the display. The comparative, linear, and BCD outputs are also retained. Refer to 5-3 External Input Signals for details. Comparative Output Selection Linear Output Communications Output HOLD Features Section 1-1

RESET is an external input to reset the present max./min. values and counting

values. The process value when the RESET is ON is set as the maximum and minimum values. The counting value is reset to zero. The max./min. values and counting values can be reset using the front panel keys. Refer to pages 104 and 105. Teaching The K3NR is provided with a teaching function that can set an actual measured value as a setting value without key input. This function is useful for setting parameters while checking the operating status of the K3NR. The teaching function can be used to set the set and prescaling values. It can be also used to set the linear output range of the K3NR with a Linear Output Board. Refer to 6-1 Teaching Function for details. Output Test This function is convenient for checking a system to which the K3NR is con- nected, especially when some inputs cannot be operated. The K3NR simulates an input to check the output conditions. Refer to 6-2 Output test for details. Hysteresis The established setting value includes a hysteresis setting to prevent “chatter- ing” of the output when the measured value fluctuates in the vicinity of the setting values. Hysteresis is enabled when the measured value is starts to become smaller than the HH and H setting values and larger than the LL and L setting values. Refer to Hysteresis, page 78. Startup Compensation Time The startup compensation time parameter keeps the measurement operation from sending an unnecessary output corresponding to instantaneous, fluctuat- ing input from the moment the K3NR is turned ON until the end of the preset peri- od. Refer to Startup Compensation Time, page 74. Remote/Local Selection The K3NR can be operated remotely through a host computer or locally with key inputs. Remote Mode: For programming remotely by downloading setup parameters from a host computer via RS-232C, RS-485, or RS-422. Local Mode: Programming is performed with the front panel key input. Refer to Remote/Local Programming, page 86. Setting process time for averaging measured value prevents the display from fluctuating due to unstable input. Refer to Process Time for Averaging Measured Value, page 72. Auto-Zero Time The input pulse frequency does not drop to zero perfectly due to the estimated frequency calculation of the K3NR. Therefore, the K3NR has a function to cali- brate the frequency to zero forcibly should no input pulse be received for a cer- tain period. The period during which no pulse is received before the K3TR sets the frequency to zero is called “auto-zero time.” Refer to page 62. RESET Process Time for Averaging Measured Value Features Section 1-1

Front of the Meter

Comparative output status indicators PV display Mode Key Status indicators SV display status indicators Teaching indicator Unit of measure SV display Shift Key Escape Key Up Key RESET/TEACH Key Five-digit (–19999 to 99999), seven-segment, 14.2-mm-high LED display with a programmable decimal point. The displays show the process value, maximum value, minimum value, opera- tions/parameters when setting, and error messages. PV Display K3NR-���A Basic Model RUN Mode: Displays the process, maximum, and minimum values. Also displays setting values while the SV indicator is lit. When changing a value, all digits other than those that can be set be- come dimmer. Setting Mode: Displays the menu, parameter, or setting value. When chang- ing a value, all digits other than those that can be set become dimmer. K3NR-���C Set Value LED Display Model RUN Mode: Displays the process, maximum, and minimum values. Setting Mode: Displays the menu and parameters. RUN Mode: Displays comparative set values. When changing a value, all digits other than those that can be set become dimmer. Setting Mode: Displays setting values. When changing a value, all digits other than those that can be set become dimmer. Indicates the status of the comparative output. SV Display (Setting value LED Display Models Only) Comparative Output Status Indicators Front of the Meter Section 1-2

Lit when the HOLD input signal is ON.

MAX Indicator Lit when the value displayed on the PV display is the maximum value. MIN Indicator Lit when the value displayed on the PV display is the minimum value. PROG Indicator Lit when the setting mode menu is displayed. The indicator flashes while param- eters are displayed. Teaching Indicator Lit when displayed parameters can be set in teaching operation. The indicator flashes when the process value is indicated as a setting value. SV Display Status Indicators Indicates which set value is on the PV or SV display. Unit of Measure Attach the appropriate label showing the unit of measure (enclosed). Used to select the process, maximum, or minimum value to be displayed on the PV display in RUN mode. Process value Maximum value Minimum value ESC ESC Used to return from the setting, protect, or maintenance mode to the RUN mode. This key is also used to return to the previous operation during the setting, pro- tect, or maintenance mode. Displays a setting value (out of HH, H, L, and LL setting values in this order) on the PV display in RUN mode when this key is pressed. Unless another operation key is pressed within five seconds after this key has been pressed, the display automatically changes to the one for process values. Process value Maximum value Minimum value HH is lit. HH setting value H setting value L setting value LL setting value H is lit. L is lit. LL is lit. No key input for 5 seconds. No key input for 5 seconds. No key input for 5 seconds. No key input for 5 seconds. In the RUN mode, this button terminates the measurement process and allows you to enter the setting mode, advancing through the menus and parameters. Menu 1 Menu 2 Menu n Parameter 1 Parameter 2 Parameter n In the setting mode, this button will store changes in the non-volatile memory while at the same time advancing the display to the next menu item. Escape Key Mode Key Front of the Meter Section 1-2

Used to select a parameter to be displayed for setting value change.

Used to increment the current digit in the setting value by one. The value increases in the following order: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, (–1), and (–) Only the leftmost digit will be displayed if the value is set to “–1” or“ –.” The value will be set to 0 if this key is pressed when “9” or “–” is displayed. Used to change the parameter displayed in setting mode. Used to scroll the digit to the right of the presently displayed digit. Used to reset the maximum value, minimum value, or counting value in RUN mode. Used to select the teaching function. Refer to 6-1 Teaching Function for details. Up Key Shift Key RESET/TEACH Key Front of the Meter Section 1-2

Rear of the Meter

Terminal arrangement varies depending on the selected Output Board. For wiring, refer to Section 2 Setup. K3NR with Relay Output Board, K31-C1, -C2, -C5 K3NR with Transistor Output Board, K31-T1, -T2 K3NR with Linear Output Board, K31-L1, -L2, -L3, -L4, -L5, -L6, -L7, -L8, -L9, -L10 K3NR with RS-485 Output Board, K31-FLK2, -FLK5 Output Board Input Board K3NR with BCD Output Board, K31-B2, -B4 Output Board Input Board K3NR with RS-232C Output Board, K31-FLK1 Communications Output Board Input Board Rear of the Meter Section 1-3

K3NR with RS-422 Output Board, K31-FLK3

Communications Output Board Terminator Input Board K3NR with RS232C + Transistor Output Board, K31-FLK4 K3NR with RS-422 + Transistor Output Board, K31-FLK6 Communications Output Board Terminator Input Board Transistor Output Board 1-4 Modes The following four modes are available. • RUN mode for normal operations (see Section 5 Operations in RUN Mode) • Setting mode for initializing parameter input (see Section 4 Parameter Setting) • Protect mode for lock-out configuration (see 4-1 Protect Mode) • Maintenance mode for initialization (see 6-3-2 Initialization) Refer to the following for the relationship among these modes and selection of the modes. RUN mode Press the Mode and Shift Keys while turning on the K3NR. Power on Press the Escape and up Keys for 1 second. Maintenance mode RUN mode 1 second Setting mode Protect mode RUN Mode K3NR is in RUN when the K3NR is turned ON. The K3NR in this mode provides an output signal as a result of the comparison of the measured and setting values. Modes Section 1-4

The basic model in this mode usually displays the process value. The maximum

and minimum values are displayed by pressing the Escape Key. The parame- ters and setting values are displayed by pressing the Mode Key. Refer to Section 5 Operations in RUN Mode for RUN mode in detail. Setting Mode Values are set in the K3NR in this mode by key input or using the teaching func- tion. Refer to Section 4 Parameter Setting for value setting by key input and 6-1 Teaching Function for the teaching function in detail. Protect Mode Use this mode to prohibit some operations in order to lock out the setting values. Refer to 4-1 Protect Mode for details. Maintenance Mode The setting values are reset to factory-set values in this mode. Refer to 6-3-2 Initialization for details. 1-5 Communications Function The communications function of the K3NR makes it possible for the host com- puter to perform the following operations. • Confirmation and change of setting values. Communications conditions can- not be changed. • Reading and resetting the maximum and minimum values. • Confirmation of model data. Use a model with the Communications Board if the communications function is required. Refer to the Communications Manual for the communications function in detail. RS-232C Use the K31-FLK1 or K31-FLK4 Output Board to use the RS-232C interface. RS-422 Use the K31-FLK3 or K31-FLK6 Output Board to use the RS-422 interface. RS-485 Use the K31-FLK2 or K31-FLK5 Output Board to use the RS-485 interface. Communications Function Section 1-5

This section provides instructions required for mounting and wiring the K3NR.

2-1 Mounting 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Input Block 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-1 Terminal Arrangement 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-2 Wiring Precautions 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2-3 Wiring 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Output Board 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-1 Terminal Arrangement 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-2 Relay Output Board 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-3 Transistor and Combination Output Board 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-4 Linear Output Board 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3-5 BCD Output Board 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

All dimensions are in millimeters.

14.2 mm 8.2 mm PV LED Indicator Size Panel Cutouts 45 +0.8 –0 92 +0.8 –0 120 min. 75 min. Recommended panel thickness is 1 to 3.2 mm. Do not mount more than one Unit closely in the horizontal or vertical direction. Be sure to keep the distance between adjacent Units. Mounting Section 2-1

1, 2, 3...

1. Insert the K3NR into the mounting hole on the panel. 2. Hook the fixture claws onto the side holes. 3. Mount a fixing metal to the right and left sides as shown above and while keeping them in balance, alternately tighten each screw until the ratchet be- comes idle. 2-2 Input Block 2-2-1 Terminal Arrangement Sensor power supply (80 mA max. at 12 VDC) Open collector input Voltage pulse input 100 to 240 to VAC 12 to 24 VDC Note Voltage pulse input is available for the K3NR-NB��-��. Input Block Section 2-2

2-2-2 Wiring Precautions

• Do not make any mistake in polarity when supply DC power to the K3NR. • Do not wire power lines alongside the signal lines of the K3NR in order to pre- vent the K3NR from noise interference. • Wire the terminal block with crimp terminals. • Tighten each screw to a torque of 0.78 N � m (8 kgf � cm). 2-2-3 Wiring Power Supply Apply 100 to 240 VAC or 12 to 24 VDC to terminals 8 and 9. Open Collector Input Connect the pulse output from sensor A to terminal 1. Connect the pulse output from sensor B to terminal 2. Terminals 10 and 11 are exclusively used for a power supply with an output of 80 mA at 12 VDC to sensor A or B. If power is supplied to the sensor A or B from a different power source, do not use terminal 10. Do not connect a sensor with open collector output to terminal 10. Refer to the following for sensor connections. Sensor (with NPN output) Sensor (with PNP output) +12 V +12 V • Residual voltage with sensor turned on: 3 V max. • Current leakage with sensor turned off: 1.5 mA max. • Switching load current: 20 mA or greater. Must be able to dependably switch a load current of 5 mA max. Photoelectric sensors, proximity sensors, rotary encoders, and relays can be connected as sensors to the K3NR. Voltage Pulse Input Connect the pulse output of sensor A to terminal 3. Connect the pulse output of sensor B to terminal 4. Terminals 10 and 11 are exclusively used for a power supply with an output of 80 mA at 12 VDC to sensor A or B. If power is supplied to the sensor A or B from a different power source, do not use terminal 10. Do not connect a sensor with voltage pulse output to terminal 10. Refer to the following for sensor connections. Sensor +12 V H level (sensor output ON): 4.5 to 30 VDC L level (sensor output OFF): –30 to 2 VDC Auxiliary Power Supply Terminals 10 and 11 are exclusively used for power supply to sensors with an output of 80 mA at 12 VDC ± 10%. Input Block Section 2-2

External Signal Input

HOLD Input RESET Input BANK Input Connect external signal inputs to terminals 5 through 7 and 13 through 15. Ter- minals 7 and 13 are connected to each other internally. Short-circuited together internally. Connect HOLD input to terminal 5. Connect RESET input to terminal 6. Connect BANK inputs to terminals 14 and 15 for BANK1 and BANK2. If open collector input is used as external signal input, the transistor must satisfy the following conditions. • Residual voltage with transistor turned on: 3 V max. • Current leakage with transistor turned off: 1.5 mA max. • Switching load current: 20 mA or greater. Approximately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input short- circuiting. Input Block Section 2-2

2-3-1 Terminal Arrangement

K3NR with Relay Output Board, K31-C1, -C2. -C5 K3NR with Transistor Output Board, K31-T1, -T2 K3NR with Linear Output Board, K31-L1, -L2, -L3, -L4, -L5, -L6, -L7, -L8, -L9, -L10 K3NR with RS-485 Output Board, K31-FLK2, -FLK5 K3NR with BCD Output Board, K31-B2, -B4 K3NR with RS232C + Transistor Output Board, K31-FLK4 Output Board Section 2-3

K3NR with RS-422 + Transistor Output Board, K31-FLK6

K3NR with RS-232C Output Board, K31-FLK1 K3NR with RS-422 Output Board, K31-FLK3 Output Board Section 2-3

2-3-2 Relay Output Board

The following figures show the connections for relay output. K3NR with 3 Relay Output Boards, K31-C1 K3NR with 5 Relay Output Boards, K31-C2 H comparative output HH comparative output H comparative output PASS output PASS output L comparative output L comparative output LL comparative output HH comparative output PASS output LL comparative output H comparative output L comparative output K3NR with 5 Relay Output Boards, K31-C5 The following contact output conditions are required. 5 A (resistive load) at 250 VAC 1.5 A (inductive load) at 250 VAC 5 A (resistive load) at 30 VDC 1.5 A (inductive load) at 30 VDC Output Board Section 2-3

2-3-3 Transistor and Combination Output Board

HH comparative output H comparative output PASS output L comparative output LL comparative output HH comparative output H comparative output PASS output L comparative output LL comparative output HH comparative output H comparative output PASS output L comparative output LL comparative output K3NR with Transistor Output Board, K31-T1 or K31-T2 K3NR with Linear Output Board, K31-L4, -L5, -L6, -L9, -L10 K3NR with RS-485 + 5 Relay Output Boards, K31-FLK5 K3NR with BCD Output Board, K31-B2 or K31-B4 K3NR with RS232C + 5 Transistor Output Boards, K31-FLK4 K3NR with RS-422 + 5 Transistor Output Boards, K31-FLK6 1 2 3 4 5 6 21 22 23 24 25 26 COM COM COM 32 33 34 35 36 37 The following transistor output conditions are required. Maximum rated voltage: 24 VDC Load current: 50 mA Current leakage with transistor turned off: 100 µA 2-3-4 Linear Output Board The following figures show connections for linear output. K3NR with Linear Output Board, K31-L1 or K31-L4 K3NR with Linear Output Board, K31-L2 or K31-L5 4 to 20 mA 1 to 5 V + – + – K3NR with Linear Output Board, K31-L3 or K31-L6 1 mV/10 digit + – The following linear output conditions are required. Linear output Permissible load resistance Resolution Output error 4 to 20 mA 600 Ω max. 4096 ±0.5% FS 1 to 5 V 500 Ω min. 4096 ±0.5% FS 1 mV/10 digit 1 kΩ min. 4096 ±1.5% FS 2-3-5 BCD Output Board Refer to Section 7 BCD Output for the terminal arrangement and interface. Output Board Section 2-3

This section provides information on the basic functions of each operating mode.

3-1 Rotational/Circumferential Speed: �� 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Absolute Ratio: �� 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Error Ratio: �� 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Rotational Difference: �� 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Flow Rate Ratio: �� 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 Passing Time: �� 37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Pulse Counting: �� 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rotational/Circumferential Speed: ��

Application example Measures the rotations of the roll. Basic Operation Multiplies the input frequency (Hz) of INA by 60 and displays the result in rpm. When the appropriate prescale value is selected, the rotational speed of the ob- ject is displayed. Obtain display value D as follows: D = fA x 60 x α fA: Input frequency of INA (Hz) α: Prescale value INB input will be ignored. Item Unit of display Prescale value Rotations rpm 1/N rps 1/60N Frequency of input pulse Hz 1/60 kHz 1/60000 Rotational speed mm/s 1000πd/60N cm/s 100πd/60N m/s πd/60N m/min πd/N km/h 0.06πd/N Where, N: Number of pulses per rotation πD: Length (m) of one rotation Example: Displaying rotations (rpm) on condition that there are two pulses per revolu- tion. Prescaling value (α) = 1/2 = 0.5 = 5.0000 x 10–1 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 5.0000 Y (exponent) of input A = –1 Refer to 4-2 Setting Mode. FUNCTION SETTING REFERENCE Rotational/Circumferential Speed: �� Section 3-1

Hold Measured Value

When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.006% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 kHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- Rotational/Circumferential Speed: �� Section 3-1

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ No Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� No Auto zero time of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ No Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Rotational/Circumferential Speed: �� Section 3-1

Absolute Ratio: ��

Operation example Measures the rotation ratio of the rolls. Basic Operation Displays the absolute ratio of the frequencies of INA and INB in percentage. Ob- tain display value D as follows: D (%) = fB x β fA x α x 100 fA: Input frequency of INA (Hz) fB: Input frequency of INB (Hz) α: Prescale value of INA β: Prescale value of INB Mode Unit of display Prescale value Absolute ratio % Na and Nb or πda/Na and πdb/Nb Where, Na: Number of pulses per revolution from A input Nb: Number of pulses per revolution from B input πda: Circumference (m) per revolution for A input πdb: Circumference (m) per revolution for B input Example: Displaying absolute revolution rate using two rotary encoders each with 1,000 output pulses per revolution. Prescale value of INA (α) = 1/1000 = 0.001 = 1.0000 x 10–3 Prescale value of INB (β) = 1/1000 = 0.001 = 1.0000 x 10–3 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 1.0000 Y (exponent) of input A = –3 X (mantissa) of input B = 1.0000 Y (exponent) of input B = –3 Refer to 4-2 Setting Mode. FUNCTION SETTING REFERENCE Absolute Ratio: �� Section 3-2

Hold Measured Value

When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.02% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 kHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- Absolute Ratio: �� Section 3-2

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ����� (See note 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ Yes Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� Yes Auto zero timer of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero timer of input B X (mantissa) Y (exponent) ������ ������ Yes Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Absolute Ratio: �� Section 3-2

Error Ratio: ��

Application example Measures the speed of the conveyor belts and the error ratio in the rotation of the conveyor belts. Basic Operation Displays the error ratio of the frequency of INA and INB in percentage. Obtain display value D as follows: D (%) = x 100 fB x β – fA x α fA x α fA: Input frequency of INA (Hz) fB: Input frequency of INB (Hz) α: Prescale value of INA β: Prescale value of INB Mode Unit of display Prescale value Error ratio % Na and Nb or πda/Na and πdb/Nb Where, Na: Number of pulses per revolution from A input Nb: Number of pulses per revolution from B input πda: Circumference (m) per revolution for A input πdb: Circumference (m) per revolution for B input Example: Displaying error ratio of two conveyor speeds (m/min) using two rotary en- coders each with 100 output pulses per revolution and a circumference of 0.125 m. Prescale value of INA (α) = 0.125/100 = 0.00125 = 1.2500 x 10–3 Prescale value of INB (β) = 0.125/100 = 0.00125 = 1.2500 x 10–3 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 1.2500 Y (exponent) of input A = –3 X (mantissa) of input B = 1.2500 Y (exponent) of input B = –3 Refer to 4-2 Setting Mode. FUNCTION SETTING REFERENCE Error Ratio: �� Section 3-3

Hold Measured Value

When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.02% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 kHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- Error Ratio: �� Section 3-3

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ Yes Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� Yes Auto zero time of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ Yes Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Error Ratio: �� Section 3-3

Rotational Difference: ��

Application example Measures the rota- tional difference of the conveyor belts. Basic Operation Displays the rotational difference of INA and INB. Obtain display value D as fol- lows: D (rpm) = fB x 60 x β – fA x 60 x α fA: Input frequency of INA (Hz) fB: Input frequency of INB (Hz) α: Prescale value of INA β: Prescale value of INB Mode Unit of display Prescale value Rotational Difference rpm INA 1/60Na INB 1/60Nb Hz (Input pulse frequency) INA 1/60 INB 1/60 mm/sec INA 1000πda/60Na INB 1000πdb/60Nb m/sec INA πda/60Na INB πdb/60Nb m/min INA πda/Na INB πdb/Nb Where, Na: Number of pulses per revolution from A input Nb: Number of pulses per revolution from B input πda: Circumference (m) per revolution for A input πdb: Circumference (m) per revolution for B input Example: Displaying error in frequency (Hz) using two rotary encoders each with 100 output pulses per revolution. Prescale value of INA (α) = 1/60 = 0.01666... � 1.6666 x 10–2 Prescale value of INB (β) = 1/60 = 0.01666... � 1.6666 x 10–2 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 1.6666 Y (exponent) of input A = –2 X (mantissa) of input B = 1.6666 Y (exponent) of input B = –2 FUNCTION SETTING Rotational Difference: �� Section 3-4

Refer to 4-2 Setting Mode.

Hold Measured Value When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.02% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 kHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- REFERENCE Rotational Difference: �� Section 3-4

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ Yes Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� Yes Auto zero time of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ Yes Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Rotational Difference: �� Section 3-4

Flow Rate Ratio: ��

Application example A B Measures the flow rate ratio of the mixture of A and B. Basic Operation From the frequency of INA and INB, displays the flow rate ratio of INB in percent- age. Obtain display value D as follows: D (%) = fB x β x 100 fA x α + fB x β fA: Input frequency of INA (Hz) fB: Input frequency of INB (Hz) α: Prescale value of INA β: Prescale value of INB Mode Unit of display Prescale value Flow rate ratio % INA Na INB Nb Where, Na: Number of pulses for specific quantity of A input Nb: Number of pulses for specific quantity of B input Example: Displaying mixed liquid concentration calculated from the flow rate ratio of two flow sensors each with a capacity of 10 �/400 rpm. Prescale value of INA (α) = 10/400 = 0.025 = 2.5000 x 10–2 Prescale value of INB (β) = 10/400 = 0.025 = 2.5000 x 10–2 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 2.5000 Y (exponent) of input A = –2 X (mantissa) of input B = 2.5000 Y (exponent) of input B = –2 Refer to 4-2 Setting Mode. FUNCTION SETTING REFERENCE Flow Rate Ratio: �� Section 3-5

Hold Measured Value

When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.02% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 kHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- Flow Rate Ratio: �� Section 3-5

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ Yes Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� No Auto zero time of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ Yes Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Flow Rate Ratio: �� Section 3-5

Passing Time: ��

Application example Measures the passing time for a conveyor line. Distance Basic Operation Measures and displays the input pulse frequency of INA in units of seconds. By selecting an appropriate prescale value, object passing time D in the range determined by the prescale value will be displayed. Obtain display value D as follows: D (sec) = 1/fA x α fA: INA input frequency (Hz) α: prescale value of INA Rotational speed = Input frequency (f) x (1/No. of pulses (N) per 1 cycle) Circumferential speed = Circumference of roll (πd) x rotational speed Passing time = Processing length (L)/Circumferential speed INB input will be ignored. Passing time is measured in this mode. Therefore, if the K3NR does not receive any pulses for a certain period, the K3NR estimates passing time using the esti- mated frequency calculation function and increases the displayed value. Mode Unit of display value Prescale value Passing time sec L/(πd/N) N = No. of pulses per 1 cycle from input A πd = Circumferential length (m) per 1 cycle L = Processing length (m) Note The K3NR can display the hour, minute, and second. Refer to page 65 for de- tails. Example: Displaying passing time (sec) using a rotary encoder with 100 output pulses per revolution. Circumference of rotary encoder = 0.125 m Process length = 5 m Prescaling value (α) = 5/(0.125/100) = 4000 = 4.000 x 103 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 4.000 Y (exponent) of input A = 3 Refer to 4-2 Setting Mode. FUNCTION SETTING REFERENCE Passing Time: �� Section 3-6

Hold Measured Value

When the HOLD input is turned ON, measurement stops and the input mea- sured just before the HOLD input turned ON is held. While the HOLD input is ON, the K3NR holds display output, comparative output, and BCD output. When the comparative output from the Output Board is connected to the HOLD input terminal, the value measured immediately after the occurrence of an error can be obtained. Performance Characteristics Accuracy of measurement ±0.006% rdg ± 1 digit (ambient temperature: 23°C ± 5°C) Measurement range Sensor with transistor output: 0.5 mHz to 50 KHz Sensor with relay output: 0.5 mHz to 30 Hz ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. Response time Output configuration Relay output Transistor output BCD and transistor output Linear and transistor output Communication and transistor output Comparative output 200 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 220 ms max. --- Passing Time: �� Section 3-6

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- Yes 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ No Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� No Auto zero time of input A X (mantissa) Y (exponent) ������ ������ Yes 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ No Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� Yes 72 Startup compensation time ����� Yes 74 Power failure memory ���� No 76 Hysteresis (See note 1) ��� Yes 78 Comparative output pattern (See note 1) ����� Yes 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Passing Time: �� Section 3-6

Pulse Counting: ��

Application example Counts the number of objects. Basic Operation Counts the number of pulses of INA and displays the result. Obtain display value D as follows: D (pulse count) = C x α C: Pulse count of INA α: Prescale value Hold Displayed Value By turning the HOLD input ON, the displayed value can be put on HOLD. While the HOLD input is ON, the pulse counting operation continues, as does compar- ative output and BCD output. In this case, using the HOLD input is similar to checking a lap time with a stopwatch. Interruption of Pulse Counting With INB input ON, the pulse counting operation is interrupted and the mea- sured value, comparative outputs, and BCD output are on HOLD. Pulse count- ing will not begin while INB input is ON. Clearing Accumulated Value When the RESET input turns ON, the accumulated value is cleared to zero. Pulse counting will not start while the RESET input is ON. The accumulated value will be stored or cleared to zero when the K3NR is turned off, and depends on the setting of the power failure memory (����) at option menu. Note By connecting comparative output with the RESET input terminal, the K3NR can be used as a single-mode preset counter. FUNCTION Pulse Counting: �� Section 3-7

With operating mode 7, comparative output L, LL, H, or HH turns ON when the

measured value exceeds the set value. Refer to following chart for details. INA input Process value RESET input HH set value HH comparative output PASS output H set value LL set value L set value H comparative output L comparative output LL comparative output Mode Unit of display value Prescale value 1 pulse = n counts Count n n pulses = 1 count Count 1/n Example: Counting four pulses as a single unit to be displayed. Prescaling value (α) = 1/4 = 0.25 = 0.25 x 100 Prescale value = X x 10Y (X: mantissa, Y: exponent) X (mantissa) of input A = 0.25 Y (exponent) of input A = 0 4-2 Setting Mode. Performance Characteristics Maximum counting speed Sensor with transistor output: 50 kcps Sensor with relay output: 30 cps Counting range 0 to 4 G (with 32-bit counter) Response time of HOLD or RESET input 20 ms max. ON/OFF pulse width Sensor with transistor output: 9 µs min. Sensor with relay output: 15 ms min. SETTING REFERENCE Pulse Counting: �� Section 3-7

10 ms max.

1 ms max. 20 ms max. 20 ms max. 1 ms max. BCD output --- --- Refer to page 115. --- --- Linear output --- --- --- 20 ms max. --- Maximum pulse counting speed is the maximum speed at which the K3NR can count INA input pulses accurately. If comparative output is used as con- trol output, the maximum pulse counting speed can be obtained as follows: Maximum counting speed (cps) = 1/Delay in comparative outputs (sec) If comparative output is directly connected to RESET input, the maximum pulse counting speed can be obtained as follows: Maximum counting speed (cps) = 1/Delay in comparative outputs (sec) + Re- sponse time of RESET input (sec) The response time of the HOLD or RESET input is the time required for the K3TR to accept HOLD or RESET input after the HOLD or RESET input turns ON. This is illustrated in the following diagram. INA Comparative output Delay in comparative outputs HOLD or RESET input Acceptance of HOLD or RESET input Response time of HOLD or RESET input (20 ms max.) Maximum Pulse Counting Speed Response Time of HOLD or RESET Input Pulse Counting: �� Section 3-7

Available functions in this mode are indicated as “Yes” in the following table.

Menu Function Displayed Character Availability Reference page --- Max./Min. value display and reset --- Yes 103 Estimated frequency calculation --- No 129 ������ (S 2) Set value bank no. of set values ������ Yes 50 (See note 2) HH set value ������ H set value ������ L set value ������ LL set value ������ ���� Select bank no. of prescale value ������ Yes 54 Prescaling value of input A X (mantissa) Y (exponent) ������ ������ Yes Prescaling value of input B X (mantissa) Y (exponent) ������ ������ No Decimal point position ������ Yes ����� Operating mode ���� Yes 58 Input A sensor type ��� Yes 60 Input B sensor type ��� Yes Auto zero time of input A X (mantissa) Y (exponent) ������ ������ No 62 Auto zero time of input B X (mantissa) Y (exponent) ������ ������ No Display time unit ���� No 65 Communications unit no. (See note 1) ���� Yes 67 Baud rate (See note 1) ��� Yes Word length (See note 1) ��� Yes 69 Stop bits (See note 1) ���� Yes Parity bits (See note 1) ���� Yes ��� Process time for averaging measured value ��� No 72 Startup compensation time ����� No 74 Power failure memory ���� Yes 76 Hysteresis (See note 1) ��� No 78 Comparative output pattern (See note 1) ����� No 80 H linear output range (See note 1) ������ Yes 83 L Linear output range (See note 1) ������ Yes Remote/Local programming (See note 1) ��� Yes 86 Note 1. The availability of the parameters depends on the type of selected Output Board. 2. The selected bank number will be displayed where an asterisk (*) appears. Available Functions Pulse Counting: �� Section 3-7

This section provides instructions for setting the parameters of the K3NR. Be sure to read this section before using the K3NR

Frequency/Rate Meter for the first time. 4-1 Overview 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-1 Heading Symbols 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1-2 Setting Procedures 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Setting Mode 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-1 Selecting Setting Mode 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-2 Menu Overview 48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-3 Setting Value Menu (�����) 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bank No. of Set Value 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HH Set Value 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H Set Value 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L Set Value 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL Set Value 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-4 Prescaling Menu (����) 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bank No. of Prescale 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescaling Value X (Mantissa) of Input A 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescaling Value Y (Exponent) of Input A 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescaling Value X (Mantissa) of Input B 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prescaling Value Y (Exponent) of Input B 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Decimal Point Position 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-5 Setup Menu (setup) 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Mode 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor Type 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Zero Time of Input A X (Mantissa) 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Zero Time of Input A Y (Exponent) 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Zero Time of Input B X (Mantissa) 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Zero Time of Input B Y (Exponent) 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Unit 65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communications Unit Number 67 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Baud Rate 67 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Word Length 69 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stop Bits 69 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parity Bits 69 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2-6 Option Menu (���) 72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Process Time for Averaging Measured Value 72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Startup Compensation Time 74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Failure Memory 76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hysteresis 78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Comparative Output Pattern 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Upper Limit (H) of Linear Output Range 83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lower Limit (L) of Linear Output Range 83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote/Local Programming 86 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Protect Mode 88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-1 Selecting Protect Mode 88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-2 Menu Overview 89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3-3 Protect Menu (����) 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . All Key Protect 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Value Change Prohibit 91 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Counting Value Reset Prohibit 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum/Minimum Value Clear Prohibit 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Security 97 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-1-1 Heading Symbols

The following symbols are used for headings in this section. This symbol precedes an explanation of the parameter’s meaning and function. This symbol precedes a description of the settings, setting range, and default value. This symbol precedes an explanation of procedures for parameters that specify operations. This symbol precedes a listing of references and related parameters. This symbol precedes a listing of the models in which this parameter can be used. 4-1-2 Setting Procedures • The K3NR has four modes: RUN mode for normal operations, Setting mode for initial parameter input, Protect mode for lock-out configuration, and Mainte- nance mode for initializing set values. The parameters that are accessible on any individual K3NR will vary depending on the Output Board installed. Refer to Appendix D Available Parameters. • The K3NR is in RUN mode when the K3NR is turned on. Parameter settings in protect or setting mode are described below on the basis that the parameters are set for the first time. For the operation in RUN mode, refer to Section 5 Operations in RUN Mode. • The setting examples are provided on condition that the factory-set values of the K3NR have not been changed. FUNCTION SETTING PROCEDURE REFERENCE MODELS Overview Section 4-1

4-2-1 Selecting Setting Mode

• The K3NR in RUN mode will go into setting mode if the Mode Key is pressed for 1 s minimum. • The K3NR in setting mode will go into RUN mode if the Escape Key is pressed. RUN mode Press the Mode and Shift Keys while turning the K3NR on. Power On Press the Escape and Up Keys for 1 second. Maintenance mode RUN mode 1 second Setting mode Protect mode • The menu in each mode changes whenever the Mode Key is pressed. • If the Mode Key is pressed for more than one second while a menu is dis- played, a parameter will be displayed. • The parameter changes whenever the Mode Key is pressed. • If the Shift Key is pressed while a parameter is displayed, the parameter will be ready to change. • Press the Up Key to change parameters. • The digit of a set value is selected with the Shift Key and changed with the Up Key. • The PROG indicator is lit while a menu or parameter is displayed. • The PROG indicator flashes during a set value change. Note If the operating mode is changed, all the other parameters will be set to default values except communication setting and set values in protect mode. Therefore, set the operating mode and sensor type first. Setting Mode Section 4-2

4-2-2 Menu Overview

Power On RUN Mode Refer to Section 5 Operations in RUN Mode. Setting Mode Press the Mode Key for 1 second. Press the Mode and Shift Keys while turning the K3NR on. Press the Escape and Up Keys for 1 second. Maintenance Mode Refer to Section 6 Useful Functions. Protect Mode Refer to 4-3 Protect Mode. Setting value menu Bank no. of set value HH setting value H setting value L setting value LL setting value Output Test Refer to Section 6 Useful Functions. Prescaling menu 1 to 4 Bank no. of prescale value Prescaling value of input A X (mantissa) Decimal point position Press the Mode Key for 1 second. (see note 1) Press the Mode Key for 1 second. Prescaling value of input A Y (exponent) Prescaling value of input B X (mantissa) Prescaling value of input B Y (exponent) Note 1. When making new settings or changing settings of each parameter, press the Shift Key to shift to the setting state. The input will be updated automatically if no change is made for five seconds. 2. The K3NR stops measurement in setting mode. Some menus cannot be set according to the Output Board selected. If the operating mode is changed, all the other parameters will be set to default values except communication setting and set values in protect mode. There- fore, set the operating mode and sensor type.

Press the Mode Key for 1 second.

Operating mode Input A sensor type Input B sensor type Auto zero time of input A X (mantissa) Auto zero time of input A Y (exponent) Time unit Communications unit no. Baud rate Word length Stop bits Parity bits Option menu Process time for averaging measured value Startup compensa- tion time Power failure memory Hysteresis Comparative out- put pattern H linear output range L linear output range Remote/Local processing Auto zero time of input B X (mantissa) Auto zero time of input B Y (exponent) Press the Mode Key for 1 second. Setting Mode Section 4-2

4-2-3 Setting Value Menu (�����)

Bank No. of Set Value HH Set Value H Set Value L Set Value LL Set Value • There are two basic methods for setting HH, H, L, and LL set values: by enter- ing during RUN mode via the front-panel buttons, setting in Setting mode, or by the teaching function. Setting Setting range Default Set value bank 1 to 4 1 HH set value –19,999 to 99999 99,999 H set value , 99,999 L set value –19999 LL set value –19999 Set the decimal point position in the prescaling menu. Refer to 6-1 Teaching Function. • The menu is only available for the K3NR with Comparative Output Board. ������ ������ ����� ����� ������ FUNCTION SETTING REFERENCE MODELS Setting Mode Section 4-2

Follow the steps described below to input the following.

Setting value bank = 2 HH setting value = “8000” H setting value = “6000” L setting value = “4000” LL setting value = “2000” Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setting value menu is displayed. The ������ setting value bank setting will be displayed. Set Value LED Display Model Basic Model 2. Press the Shift Key to display the set value � for changing. The PROG indi- cator will flash. Set Value LED Display Model Basic Model 3. Press the Up Key to set the value to �. The input will be validated automati- cally if no change is made for five seconds. The ������ setting value bank setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ������ HH setting value of bank 2 setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 4. Press the Mode Key to display the ������ HH setting value of bank 2 setting. Set Value LED Display Model Basic Model 5. Press the Shift Key to display the set value ����� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model SETTING EXAMPLE Setting Mode Section 4-2

6. Press the Up and Shift Keys to set the value to ����. The input will be vali-

dated automatically if no change is made for five seconds. The ������ HH setting value of bank 2 setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ����� H setting value of bank 2 setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 7. Press the Mode Key to display the ����� H setting value of bank 2 setting. Set Value LED Display Model Basic Model 8. Press the Shift Key to display the set value ����� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 9. Press the Up and Shift Keys to set the value to ����. The input will be vali- dated automatically if no change is made for five seconds. The ������ H set- ting value of bank 2 setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ������ L setting value of bank 2 setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 10. Press the Mode Key to display the ������ L setting value of bank 2 setting. Set Value LED Display Model Basic Model 11. Press the Shift Key to display the set value ������ for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model Setting Mode Section 4-2

12. Press the Up and Shift Keys to set the value to ����. The input will be vali-

dated automatically if no change is made for five seconds. The ������ L set- ting value of bank 2 setting will be displayed again. Note Press the Mode Key to enter the input immediately. The ������ LL setting value setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 13. Press the Mode Key to display the ������ LL setting value of bank 2 setting. Set Value LED Display Model Basic Model 14. Press the Mode Key to display the set value ������ for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 15. Press the Up and Shift Keys to set the value to ����. The input will be vali- dated automatically if no change is made for five seconds. The ������ LL setting value setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ������ setting value bank setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 16. Press the Escape Key to display the ����� setting value menu. Set Value LED Display Model Basic Model Set Value LED Display Model Basic Model Setting Mode Section 4-2

4-2-4 Prescaling Menu (����)

Bank No. of Prescale Prescaling Value X (Mantissa) of Input A Prescaling Value Y (Exponent) of Input A Prescaling Value X (Mantissa) of Input B Prescaling Value Y (Exponent) of Input B Decimal Point Position To display rotational speeds, circumferential speeds, or other values based on input pulse calculations, the rotational speed must be multiplied by a factor input before the input pulses are measured. This factor is called a prescale value. Display value = Measured data x Prescaling value Prescaling values can be set within a range between 0.0001 x 10–9 and 9.9999 x 109. Example: Setting prescaling value with the input of two pulses per revolution. Unit: rpm Operating Mode: 1 Object to be measured Proximity Sensor Two pulses are output per revolution. Therefore, the prescaling value is calcu- lated: 0.5 x 100 = 5.0 x 10–1 ������ = ��� ����� = ������ ����� = ����� Note Use prescaling banks 1 through four if more than one prescaling value needs to be set. Input type Setting Default ������: Bank no. of prescale OFF/1 to 4 OFF ������: Prescaling value X (mantissa) of input A 0.0001 to 9.9999 1.0000 ������: Prescaling value Y (exponent) of input A –9 to 9 0 ������: Prescaling value X (mantissa) of input B 0.0001 to 9.9999 1.0000 ������: Prescaling value Y (exponent) of input B –9 to 9 0 ������: Decimal point position Operating modes 3 and 4: One of the 1st to 3rd digits from the right Other modes: One of the 1st to 4th digits from the right No decimal point position setting ������ ������ ������ ������ ������ ������ FUNCTION SETTING Setting Mode Section 4-2

Refer to 6-1 Teaching Function.

Follow the steps described below to input the following. Operating mode = F1 Prescaling bank = OFF Prescaling value X (mantissa) of input A = 0.5000 Prescaling value Y (exponent) of input A = –1 Decimal point = ����.� (1st digit from the right) Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ���� prescaling menu is displayed. The ������ prescaling bank setting will be displayed. Set Value LED Display Model Basic Model 2. Press the Shift Key to display ��� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 3. Press the Up Key to change the prescaling bank setting. The input will be validated automatically if no change is made for five seconds. The ������ prescaling bank setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ����� prescaling value X (mantissa) of input A setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 4. Press the Mode Key to display the ����� prescaling value X (mantissa) of input A setting. Set Value LED Display Model Basic Model REFERENCE SETTING EXAMPLE Setting Mode Section 4-2

5. Press the Shift Key to display the set value ������ for changing. The PROG

indicator will flash. Set Value LED Display Model Basic Model 6. Press the Up and Shift Keys to set the value to ������. The input will be vali- dated automatically if no change is made for five seconds. The ����� pres- caling value X (mantissa) of input A setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ����� prescaling value X (mantissa) of input A setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 7. Press the Mode Key to display the ����� prescaling value Y (exponent) of input A setting. Set Value LED Display Model Basic Model 8. Press the Shift Key to display the set value ���� for changing. Set Value LED Display Model Basic Model 9. Press the Up and Shift Keys to set the value to �����. The input will be vali- dated automatically if no change is made for five seconds. The ����� pres- caling value Y (exponent) of input A setting will be displayed again. Note a) Press the Mode Key to enter the set value immediately. The ���� decimal point position setting will be displayed again. b) If the set operating mode is F2 through F5, the ����� prescaling value X (mantissa) of input B setting will be displayed. Set Value LED Display Model Basic Model Setting Mode Section 4-2

10. Press the Mode Key to display the ���� decimal point position setting.

Note If the set operating mode is F2 through F5, the ����� prescaling value X (mantissa) of input B setting will be displayed. Set Value LED Display Model Basic Model 11. Press the Shift Key to display ����� for changing. Set Value LED Display Model Basic Model 12. Press the Shift Key to set ������. The input will be validated automatically if no change is made for five seconds. The ���� decimal point position setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The ������ prescaling bank setting will be displayed for setting the next parame- ter. Set Value LED Display Model Basic Model 13. Press the Escape Key to display the ���� prescaling menu. Set Value LED Display Model Basic Model Set Value LED Display Model Basic Model Setting Mode Section 4-2

4-2-5 Setup Menu (�����)

Operating Mode Use this menu to select the operating mode of the K3NR. All parameters will be set to default values if any change is made in this parameter except to those for the communications and protect settings. ��: Displays the number of circumferential or rotational speed of in- put A. �� through ��: Displays the result of the arithmetic operation of two different revolutions. ��: Displays the value of passing time calculated from the frequen- cy or processing length of input A. ��: Displays the pulse counting of input A. Setting Default ��: Rotational/circumferential speed ��: Absolute ratio ��: Error ratio ��: Rotational difference ��: Flow rate ratio ��: Passing time ��: Pulse counting �� Refer to Section 3 Operating Modes. Follow the steps described below to select the �� rotational difference setting. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model 2. Press the Shift Key to display �� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model ���� FUNCTION SETTING REFERENCE SETTING EXAMPLE Setting Mode Section 4-2

3. Repeatedly press the Up Key until �� is displayed. The displayed setting will

be validated automatically if no change is made for five seconds. The ���� operating mode setting will be displayed again. Note Press the Mode Key to enter the displayed setting immediately. The next parameter will be displayed for setting. Set Value LED Display Model Basic Model 4. Repeatedly press the Escape Key until the ����� setup menu is displayed. Set Value LED Display Model Basic Model Setting Mode Section 4-2

• Specifies the type of sensors for input A and input B.

• The sensor type of input B cannot be selected if the operating mode of the K3NR is set to �� (rotational/circumferential speed) or �� (passing time). • Open Collector Input Sensor type Normally open Normally closed Default Transistor input �� �� �� Relay input �� �� Normally Open Model: The sensor output is OFF (open) when the sensor is not sensing an object. Normally Closed Model: The sensor output is ON (closed) when the sensor is not sensing an object. • Voltage Pulse Input Sensor type Active high (H) Active low (L) Default Voltage pulse input �� �� �� Follow the steps described below to set input A to �� in operating mode �� (rotational/cir- cumferential speed). Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model 2. Press the Mode Key to display ��� input A sensor type setting. Set Value LED Display Model Basic Model 3. Press the Shift Key to display �� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model ��� ��� FUNCTION SETTING SETTING EXAMPLE Setting Mode Section 4-2

4. Press the Up and Shift Keys to display ��. The displayed value will be vali-

dated automatically if no change is made for five seconds. The ��� input A sensor type setting will be displayed again. Note Press the Mode Key to enter the displayed setting immediately. The next parameter will be displayed. Set Value LED Display Model Basic Model 5. Press the Escape Key to display the ����� setup menu. Set Value LED Display Model Basic Model Setting Mode Section 4-2

Auto Zero Time of Input A X (Mantissa)

Auto Zero Time of Input A Y (Exponent) Auto Zero Time of Input B X (Mantissa) Auto Zero Time of Input B Y (Exponent) Calibrates the process value to zero forcibly if no input pulse is received for a certain period. This period is called auto-zero time. Refer to the following graph. Frequency Auto-zero time Time Logically, the input pulse frequency does not drop to zero perfectly due to the estimated frequency calculation of the K3NR. Therefore, the K3NR has a func- tion to calibrate the frequency to zero forcibly if no input pulse is received for a certain period. Automatic zero time is determined by the following formula. Auto-zero time = X x 10Y (s) (X: mantissa, Y: exponent) Note Auto-zero time must be longer than the value obtained by dividing one by the minimum frequency input of the K3NR. Auto-zero time must not be less than 0.1 s. If the operating mode of the K3NR is set to F7 (pulse counting), this parameter will not be available. Input type Setting Default ������: Auto zero time of input A X (mantissa) ������: Auto zero time of input A Y (exponent) ������: Auto zero time of input B X (mantissa) ������: Auto zero time of input B Y (exponent) 0.0001 to 9.9999 –9 to 09 0.0001 to 9.9999 –9 to 09 9.9999 09 9.9999 09 Note For details, refer to page 129 for the estimated frequency calculation of the K3NR. Follow the steps described below to set the value of auto-zero time to one second. Set Value LED Display Model Basic Model ������ ������ ������ ������ FUNCTION SETTING REFERENCE SETTING EXAMPLE Setting Mode Section 4-2

1, 2, 3...

1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ������ auto zero time of input A X (mantissa) setting is displayed. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the set value ������ for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up and Shift Keys to set the value to ������. The input will be vali- dated automatically if no change is made for five seconds. The ������ auto zero time of input A X (mantissa) setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The auto zero time of input A Y (exponent) setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 5. Press the Mode Key to display the ������ auto zero time of input A Y (expo- nent) setting. Set Value LED Display Model Basic Model 6. Press the Shift Key to display the set value ����� for changing. Set Value LED Display Model Basic Model 7. Press the Up and Shift Keys to set the value to �����. The input will be vali- dated automatically if no change is made for five seconds. The ������ auto zero time of input A Y (exponent) setting will be displayed again. Setting Mode Section 4-2

Note Press the Mode Key to enter the set value immediately. The auto zero

time of input B X (mantissa) setting will be displayed for setting the next parameter. Set Value LED Display Model Basic Model 8. Press the Escape Key to display the ����� setup menu. Set Value LED Display Model Basic Model Setting Mode Section 4-2

The time unit can be selected to display the calculation results of F6 (passing

time). Unit Display range Default ���� –19999 to 99,999 ���� ��� Displayed in seconds within a range between 0 and 99,999 s. ��� Displayed minutes within a range between 0 and 99,999 min. ������� Displayed in hours, minutes, and seconds within a range between 0 h, 00 min, 00 s and 9 hrs, 59 min, 59 s. ������� Displayed in minutes and seconds (1/100 s) within a range between 00 min, 00 s 0 and 59 min, 59 s, 9. Follow the steps described below to set ��� second unit setting. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until ���� time unit setting is displayed. Set Value LED Display Model Basic Model 3. Press the Shift Key to display ���� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model ���� FUNCTION SETTING SETTING EXAMPLE Setting Mode Section 4-2

4. Press the Up Key to display ���. The input will be validated automatically if

no change is made for five seconds. The ���� time unit setting will be dis- played again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model 5. Press the Escape Key to display the ����� setup menu. Set Value LED Display Model Basic Model Set Value LED Display Model Basic Model Setting Mode Section 4-2

Communications Unit Number

Baud Rate • Set a communications unit number as an identification number by which the host computer is connected to the K3NR. • If more than one K3NR is connected in parallel, make sure that each commu- nications unit number is unique. • The baud rate should be set to the baud rate of the host computer. • Communications Unit Number Setting range Unit Default 00 to 99 --- 00 • Baud Rate Setting range Default ����: 1,200 bps / ����: 2,400 bps /�����: 4,800 bps / ����: 9,600 bps / �����:19.2 Kbps / �����: 38.4 Kbps 9600 This setting is available for the K3NR with the Communications Output Board. Follow the steps described below to set the communications unit number to 15 and the baud rate to 19,200 bps. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ���� communications unit number setting is displayed. Set Value LED Display Model Basic Model ���� ��� FUNCTION SETTING MODELS SETTING EXAMPLE Setting Mode Section 4-2

3. Press the Shift Key to display the prior set value �� for changing. The PROG

indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up and Shift Keys to set the value to ��. The input value will be validated automatically if no change is made for five seconds. The ���� communications unit number setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model 5. Press the Mode Key to display the ��� baud rate setting. Set Value LED Display Model Basic Model 6. Press the Shift Key to display the prior set value ���� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 7. Press the Up Key to set the value to �����. The input will be validated auto- matically if no change is made for five seconds. The ��� baud rate setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed again for setting. Set Value LED Display Model Basic Model 8. Press the Up Key to enter the set value for setting the next parameter. The input value will be validated automatically if no change is made for five se- conds. The ��� baud rate setting will be displayed again. Set Value LED Display Model Basic Model Setting Mode Section 4-2

• The communications format used for communicating with the host computer is

set in the setup menu. • Refer to the Communications Manual for the communications format in detail. • Word Length Setting Unit Default 7/8 bit 7 • Stop Bits Setting Unit Default 1/2 bit 2 • Parity Bit Setting Default ����: None ����: Even ���: Odd ���� This setting is available for the K3NR with the Communications Output Board. Follow the steps described below to set the following. Word length: 8 bits Number of stop bits: 1 Parity bits: ���� Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ����� setup menu is displayed. The ���� operating mode setting will appear. Set Value LED Display Model Basic Model ��� ���� ���� FUNCTION SETTING MODELS SETTING EXAMPLE Setting Mode Section 4-2

2. Repeatedly press the Mode Key until the ��� word length setting is dis-

played. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior set value � for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up Key to set the value to �. The input value will be validated auto- matically if no change is made for five seconds. The ��� word length setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model 5. Press the Mode Key to display the ���� stop bit setting. Set Value LED Display Model Basic Model 6. Press the Shift Key to display the set value � for changing. Set Value LED Display Model Basic Model 7. Press the Up Key to set the value to �. The input will be validated automati- cally if no change is made for five seconds. The ���� stop bit setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model 8. Press the Mode Key to display the ���� parity bit setting. Set Value LED Display Model Basic Model Setting Mode Section 4-2

9. Press the Shift Key to display ���� for changing.

Set Value LED Display Model Basic Model 10. Press the Up Key to display ����. The setting will be validated automatically if no change is made for five seconds. The ���� parity bit setting will be dis- played again. Note Press the Mode Key to enter the setting immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model Setting Mode Section 4-2

4-2-6 Option Menu (���)

Process Time for Averaging Measured Value The K3NR averages its measured value at regular preset intervals. Therefore, when the K3NR is used to measure the rpm of a machine, for example, the value indicated by the PV display will be stable without being influenced by the fluctua- tion of the input pulse intervals or the rotation of the machine. If the input pulse intervals are larger than the preset regular intervals, the K3NR calculates the rpm using the input pulse intervals. Setting Default ����: Averaged every 60 ms ���: Averaged every 500 ms �: Averaged every 1 s �: Averaged every 2 s �: Averaged every 4 s �: Averaged every 8 s ��: Averaged every 16 s ���� Input value Display value Without average processing Input value Display value After average processing ��� FUNCTION SETTING REFERENCE Setting Mode Section 4-2

Follow the steps described below to set the process time for averaging measured value

to 4 s. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� process time for averaging measured value setting will appear. Set Value LED Display Model Basic Model 2. Press the Shift Key to display present set value ���� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 3. Repeatedly press the Up Key until � is displayed. The setting will be vali- dated automatically if no change is made for five seconds. The ��� process time for averaging measured value setting will be displayed again. Note Press the Mode Key to enter the displayed setting immediately. The next parameter will be displayed. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model SETTING EXAMPLE Setting Mode Section 4-2

Startup Compensation Time

• The interval between the moment the K3NR is turned and the moment the K3NR starts measurement operation is set in the option menu. • The startup compensation time parameter keeps the measurement operation from sending an unnecessary output corresponding to instantaneous, fluctu- ating input from the moment the K3NR is turned ON until the end of the preset period. Setting range Unit Default 0.0 to 99.9 S 0.0 The K3NR will display “�����” with all outputs turned OFF until the K3NR is in measurement operation. L set value L comparative output Power ON Display = 00000 (measurement interrupted) Setting time Display Time Follow the steps described below to set the startup compensation time to 2 seconds. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� process time for averaging measured value setting will appear. Set Value LED Display Model Basic Model ����� FUNCTION SETTING REFERENCE SETTING EXAMPLE Setting Mode Section 4-2

2. Press the Mode Key to display the ����� startup compensation time setting.

Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior set value ���� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up and Shift Keys to set the value to ����. The setting will be vali- dated automatically if no change is made for five seconds. The ����� start- up compensation time setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model Setting Mode Section 4-2

Power Failure Memory

Retains the process value at the time of power failure if the operating mode of the K3NR is set to F7 (pulse counting). Setting Default ��: Stored ���: Not Stored ��� Follow the steps described below to set �� to enable power failure memory. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� average processing setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ���� power failure memory setting is displayed. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the set data ��� for changing. The PROG indi- cator will flash. Set Value LED Display Model Basic Model 4. Press the Up Key to display ��. The setting will be validated automatically if no change is made for five seconds. The ���� power failure memory setting will be displayed again. Note Press the Mode Key to enter the displayed setting immediately. The next parameter will be displayed for setting. Set Value LED Display Model Basic Model ���� FUNCTION SETTING SETTING EXAMPLE Setting Mode Section 4-2

When no operation is executed for five seconds

Set Value LED Display Model Basic Model 5. Press the Escape Key to display the ��� option menu. Set Value LED Display Model Basic Model Setting Mode Section 4-2

• The hysteresis can be set in the option menu to prevent “chattering” of the out-

put if the measured value fluctuates in the vicinity of the setting values. • The hysteresis can be set within a range of 1 and 9999 digits for four consecu- tive digits beginning with the leftmost digit regardless of the decimal point. • The value set to 0 is regarded as 1. • The decimal point position set in the scaling menu becomes valid. Setting range Unit Default 1 to 9999 --- 1 If the comparative output is a level output, however, the hysteresis will be en- abled when the measured value starts to become smaller than the HH, H, LL, and L setting values. Measured value H setting value L setting value H comparative output L comparative output Hysteresis Hysteresis This setting is only available for the K3NR with the Comparative Output Unit. Follow the steps described below to set the hysteresis to 30. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� average processing setting will appear. Set Value LED Display Model Basic Model ��� FUNCTION SETTING REFERENCE MODELS SETTING EXAMPLE Setting Mode Section 4-2

2. Repeatedly press the Mode Key until the ��� hysteresis setting is displayed.

Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior set value ���� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up and Shift Keys to set the value to ����. The setting will be vali- dated automatically if no change is made for five seconds. The ��� hystere- sis setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model Setting Mode Section 4-2

Comparative Output Pattern

• The pattern of HH, H, L, LL, and PASS comparative outputs is set in the option menu. • This function is not available when the operating mode is set to “F7.” Setting Default �����: Standard output ����: Zone output �����: Level output ����� Standard Output H or HH Comparative Output: Turns ON when the measured value is larger than the H or HH setting value. PASS Output: Turns ON when LL, L, H, and HH comparative outputs are all OFF. L or LL Comparative Output: Turns ON when the measured value is smaller than the L or LL setting value. HH setting value H setting value L setting value LL setting value Measured value HH comparative output H comparative output PASS L comparative output LL comparative output ����� FUNCTION SETTING REFERENCE Setting Mode Section 4-2

LL, L, H, or HH Comparative Output:

Turns ON when the measured value exceeds the LL, L, H, or HH setting value. PASS Output: Turns ON when the LL, L, H, and HH comparative outputs are all OFF. HH setting value H setting value L setting value LL setting value Measured value HH comparative output H comparative output PASS L comparative output LL comparative output Zone Output HH Comparative Output: Turns ON when the measured value exceeds the HH setting value. H Comparative Output: Turns ON when the measured value is between the H and HH setting values. PASS Output: Turns ON when the measured value is between the L and H setting values. L Comparative Output: Turns ON when the measured value is between the LL and L setting values. LL Comparative Output: Turns ON when the measured value falls below the LL setting value. Be sure to set the setting values so they satisfy the following formula: LL < L < H < HH HH setting value H setting value L setting value LL setting value Measured value HH comparative output H comparative output PASS L comparative output LL comparative output Setting Mode Section 4-2

This setting is only available for the K3NR with the Comparative Output Unit.

Follow the steps described below to set the comparative output pattern to level output. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� process time for averaging measured value setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ����� comparative output pattern setting is displayed. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior setting ����� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up Key twice to display �����. The setting will be validated auto- matically if no change is made for five seconds. The ����� comparative out- put pattern setting will be displayed again. Note Press the Mode Key to enter the setting immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model MODELS SETTING EXAMPLE Setting Mode Section 4-2

Upper Limit (H) of Linear Output Range

Lower Limit (L) of Linear Output Range Linear output setting is made in the option menu to enable the K3NR to have voltage or current output in proportion to the change in display value. • The maximum and minimum values of linear output are set in this parameter. Linear output 20 mA or 5 V Display value 4 mA or 1 V • L can be greater or less than H. • L cannot be the same as H, otherwise H will be automatically set to a value obtained by adding 1 to L. • The teaching function can be used for setting linear output ranges. Setting range Default –19999 to 99999 H linear output range 99999 L linear output range –19999 Refer to 6-1 Teaching Function. This setting is available for the K3NR with the Linear Output Board. ������ ������ FUNCTION SETTING REFERENCE MODELS Setting Mode Section 4-2

Follow the steps described below to set the following.

H: 100.00 L: 0.00 (Assume that the decimal point is set between the 2nd and 3rd digit from the right in the prescale menu.) Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� process time for averaging measured value setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ������ H linear output range set- ting is displayed. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior set value ������ for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up and Shift Keys to set the value to ������. The setting will be validated automatically if no change is made for five seconds. The ������ H linear output range setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. + Set Value LED Display Model Basic Model 5. Press the Mode Key to display the ������ L linear output range setting. Set Value LED Display Model Basic Model SETTING EXAMPLE Setting Mode Section 4-2

6. Press the Shift Key to display the prior set value ������� for changing. The

PROG indicator will flash. Set Value LED Display Model Basic Model 7. Press the Up and Shift Keys to set the value to ������. The setting will be validated automatically if no change is made for five seconds. The ������ L linear output range setting will be displayed again. Note Press the Mode Key to enter the set value immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Set Value LED Display Model Basic Model Setting Mode Section 4-2

• The K3NR can be set to remote or local mode in the option menu. The K3NR in

remote mode is operated through the host computer and the K3NR in local mode is operated through the front panel key input. Setting Default Remote: ��� Local: ��� ��� This setting is available for the K3NR with the Communications Output Board. Follow the steps described below to set the K3NR to remote programming. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ��� option menu is displayed. The ��� setting will appear. Set Value LED Display Model Basic Model 2. Repeatedly press the Mode Key until the ��� remote/local setting is dis- played. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior setting ��� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 4. Press the Up Key to display ���. Set Value LED Display Model Basic Model ��� FUNCTION SETTING MODELS SETTING EXAMPLE Setting Mode Section 4-2

5. The setting will be validated automatically if no change is made for five se-

conds. The ��� process time for averaging measured value setting will be displayed again. Note Press the Mode Key to enter the setting immediately. The ��� re- mote/local setting will be displayed again. Set Value LED Display Model Basic Model Setting Mode Section 4-2

4-3-1 Selecting Protect Mode

• The K3NR in RUN mode will go into protect mode if the Escape and Up Keys are pressed for more than 1 second. • The K3NR in protect mode will go into RUN mode if the Escape Key is pressed. Press the Mode and Shift Keys while turning the K3NR on. Power On Press the Escape and Up Keys for 1 second. Maintenance mode RUN mode Setting mode Protect mode 1 second • If the Mode Key is pressed for more than one second while a menu is dis- played, a parameter will be displayed. • The parameter changes whenever the Mode Key is pressed. • If the Shift Key is pressed while a parameter is displayed, the parameter will be ready to change. • Press the Up Key to change parameters. Protect Mode Section 4-3

4-3-2 Menu Overview

Power On RUN Mode Refer to Section 5 Operations in RUN Mode. Press the Escape and Up Keys for 1 second. Protect Mode Press the Mode and Shift Keys while turning the K3NR on. Press the Mode Key for 1 second. Maintenance Mode Setting Mode Refer to Section 6 Useful Functions. Refer to 4-2 Setting Mode. Protect menu All key protect Key protect ON Key protect OFF Setting value change prohibit Key protect ON Key protect OFF Key protect ON Key protect OFF Key protect ON Key protect OFF Counting value reset prohibit Max./Min. value clear prohibit Security No key input for 5 seconds. No key input for 5 seconds. No key input for 5 seconds. No key input for 5 seconds. No key input for 5 seconds. All menus prohibited: 2 Setup menu prohibited: 1 All menu allowed: 0 Note 1. The K3NR stops measurement in setting mode. 2. Some menus cannot be set due to the display type or output type selected. Protect Mode Section 4-3

4-3-3 Protect Menu (����)

All Key Protect • The operation of all keys can be prohibited in the protect menu. Setting Default ����: Key protect ON �����: Key protect OFF ����� Follow the steps described below to set the key protect to ON. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ���� protect menu is displayed. The ��� all key protect setting will appear. Set Value LED Display Model Basic Model 2. Press the Shift Key to display the prior setting ����� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model 3. Press the Up Key to display ����. The setting will be validated automatically if no change is made for five seconds. The ��� all key protect setting will be displayed again. Note Press the Mode Key to enter the setting immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds ��� FUNCTION SETTING SETTING EXAMPLE Protect Mode Section 4-3

Setting Value Change Prohibit

• The setting value change of the K3NR in RUN mode with the front-panel key inputs can be prohibited in the protect menu. Setting Default ����: Key protect ON �����: Key protect OFF ����� Refer to 5-1 Checking and Changing Setting Values. This setting is only available for the K3NR with the Comparative Output Unit. Follow the steps described below to set the setting value change prohibit to ON. Set Value LED Display Model Basic Model 1, 2, 3... 1. Press the Mode Key for more than one second while the ���� protect menu is displayed. The ��� all key protect setting will appear. Set Value LED Display Model Basic Model 2. Press the Mode Key to display the ����� setting value prohibit setting. Set Value LED Display Model Basic Model 3. Press the Shift Key to display the prior setting ����� for changing. The PROG indicator will flash. Set Value LED Display Model Basic Model ����� FUNCTION SETTING REFERENCE MODELS SETTING EXAMPLE Protect Mode Section 4-3

4. Press the Up Key to display ����. The setting will be validated automatically

if no change is made for five seconds. The ����� setting value prohibit set- ting will be displayed again. Note Press the Mode Key to enter the setting immediately. The next pa- rameter will be displayed for setting. Set Value LED Display Model Basic Model When no operation is executed for five seconds Protect Mode Section 4-3