Mobeye argos i200 Operation & User’s Manual

File Specifications

Brand: Mobeye
Category: Security System
Model: argos i200 (Operation & User’s Manual), prqkztcCvsxTM
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 27 pages

Download PDF

Download Mobeye argos i200 Manual (27 pages)

Read Online:

Read the Mobeye argos i200 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Attention! Very important

This user manual contains important guidelines for the installation and usage of the Mobeye Argos. Please read these thoroughly before you start using the Mobeye Argos! In case of damage caused by disregarding the guidelines, the warranty becomes void. The user must regularly check the proper functioning of the Mobeye Argos. The manufacturer cannot be held liable for any damage or loss caused by any incorrect use or incorrect functioning of the Mobeye Argos. Safety guidelines • The permitted ambient temperature during operation may not be exceeded (not lower than - ...

Attention! Very important

This user manual contains important guidelines for the installation and usage of the Mobeye Argos. Please read these thoroughly before you start using the Mobeye Argos! In case of damage caused by disregarding the guidelines, the warranty becomes void. The user must regularly check the proper functioning of the Mobeye Argos. The manufacturer cannot be held liable for any damage or loss caused by any incorrect use or incorrect functioning of the Mobeye Argos. Safety guidelines • The permitted ambient temperature during operation may not be exceeded (not lower than - ...

Pulse time siren/output 2 Keypad

82 1..9999 (sec.) 120 SMS TO2: Repeat Keypad 84 0..99 (hours) 4 SMS REPEAT: Power failure message Keypad 86 0 (off), 1 (on) 1 (ON) SMS POWERSMS: ON / OFF TEL1 Keypad 101 Telephone number SMS TEL1: TEL2 Keypad 102 Telephone number SMS TEL2: TEL3 Keypad 103 Telephone number SMS TEL3: TEL4 Keypad 104 Telephone number SMS TEL4: TEL5 Keypad 105 Telephone number SMS TEL5: Delete telephone number Keypad 101…105 0 SMS DEL1….DEL5 Authorise telephone ...

13. COMPLETE LIST OF SETTINGS

Setting Menu/ command Options Factory default Installation code Keypad 00 4 digits 1111 SMS INSTCODE: Sensitivity PIR Keypad 03 1 (high) of 2 (low) 1 (high) SMS SENS: Entry delay Keypad 04 1, 15, 30, 45 or 60 15 SMS ENTRYDELAY: Interval test message Keypad 05 0, 1, 2, 3, … or 30 (days) 0 SMS TEST: Entry indication Keypad 07 0 (off), 1 (on), (LED) 0 (OFF) SMS ENTRYBEEP: ON, OFF, LED Sirene Keypad 08 0 (off), 1 (on) 0 (OFF) SMS SIREN: ON, OFF Exit indication Keypad 09 0 (off), 1 (on) 1 (ON) SMS EXITBEEP: ON, OFF SMS on/off Keypad 12 0 (off), 1 (on) 1 (ON) SMS S ...

7. CONNECTING SENSORS, DEVICES AND EXTERNAL POWER

In addition to the integrated movement sensor and temperature sensor, external sensors can be connected as alarm input. The Mobeye Argos can also switch external devices connected to it via the outputs when an event triggers it (like an alarm or incoming call). And although the Mobeye Argos is designed to run on batteries, it is possible to use an external power supply in order to report power failure and to remotely control the system. In following chapters the inputs, outputs and external power settings are explained. Please find below the ...

13. COMPLETE LIST OF SETTINGS

Setting Menu/ command Options Factory default Installation code Keypad 00 4 digits 1111 SMS INSTCODE: Sensitivity PIR Keypad 03 1 (high) of 2 (low) 1 (high) SMS SENS: Entry delay Keypad 04 1, 15, 30, 45 or 60 15 SMS ENTRYDELAY: Interval test message Keypad 05 0, 1, 2, 3, … or 30 (days) 0 SMS TEST: Entry indication Keypad 07 0 (off), 1 (on), (LED) 0 (OFF) SMS ENTRYBEEP: ON, OFF, LED Sirene Keypad 08 0 (off), 1 (on) 0 (OFF) SMS SIREN: ON, OFF Exit indication Keypad 09 0 (off), 1 (on) 1 (ON) SMS EXITBEEP: ON, OFF SMS on/off Keypad 12 0 (off), 1 (on) 1 (ON) SMS S ...

9.4 POWER FAILURE DELAY TIME

The power failure delay time defines the time that the power fails before an alarm is initiated. If the power is restored within the delay time, no alarm is sent. The delay time can be set between 0 and 60 minutes. As default, the delay time is set to 1. 9.5 AUTHORISATIONS AND REMOTE CONTROL When connected to an external power, the GSM module is active all the time, able to receive SMS commands. This enables both programming and remote control. Remote control actions are: arming, disarming and switching the outputs. As prerequisite for remote control the ‘cont ...

Mobeye argos i200 user guide recommended for: CM2500, Caddx, SG5550, PresencePlus P4 EDGE, i110.

⚠️ Download Safety

The Security System Operation & user’s manual (27 pages) is completely safe to download (last scan date: 08/05/2026).

Related PDF Instructions for Mobeye argos i200:

Security System Equipment: Frequently Requested

Have some Questions about Mobeye argos i200 Device?

Get valuable and actionable advices from other Mobeye argos i200 device users. Describe your problem or question, regarding the using of argos i200, in as much detail as possible, and other users will be able to answer you.